NRBM Series
NRBM Series
Switches & Pilot Lights
NRBM circuit breakers are the largest in rated current (1A to 50A) among the IDEC circuit
breakers series. These small sized, high-efciency breakers offer a variety of protection
characteristics that can be widely employed for semiconductors, relay circuits, heater
circuits, transformers, and solenoids.
Display Lights
License #113434
General Specications
Series current trip
Number of Poles
1, 2, 3
Rated Voltage
Current trip: 1A, 2A, 3A, 5A, 7.5A, 10A, 15A, 20A, 25A, 30A, 40A, 50A
SPDT microswitch
250V AC, 5A (resistive load)
50V DC, 1 A (resistive load)
Reference Temperature
25C
Insulation Resistance
Dielectric Strength
Vibration Resistance
Shock Resistance
Life Expectancy
Terminal Style
Weight
1-pole/100g
2-pole/200g
3-pole/300g
Terminal Blocks
Internal Circuit
Timers
Electromagnetic tripping
Protection Method
Circuit Breakers
USA: 800-262-IDEC
Canada: 888-317-IDEC
893
Circuit Breakers
NRBM Series
NRBM
1
j Poles
11
k Internal
Circuit
l Auxiliary and
Alarm Contacts
m Inertia Delay
30A
n Rated Current
AA
o Time Delay Curve
Description
j No. of Poles
k Internal Circuit
l Auxiliary and
Alarm Contacts
m Inertia Delay
n Rated Current
o Time Delay Curve
Remarks
1-pole
2-pole
3-pole
Without
00
11
21
Blank
All multiple pole circuit breakers are simultaneous throw/simultaneous break. All
levers are mechanically interlocked.
AC curves
AA, BA,MA
DC curves
AD, MD
Circuit Breakers
Terminal Blocks
Timers
894
www.idec.com
Circuit Breakers
NRBM Series
Information About Circuit Breakers
Switches & Pilot Lights
NRBM Application
AD, AA
BA
Response to overcurrent is quite fast. Suited for protection of semiconductor circuits with very little overload tolerance. If overcurrents are expected to
ow, fuses may be required according to the circuit characteristics.
MD, MA
Suited for motor loads that draw high inrush currents lasting a considerable length of time.
Designed not to trip on 20 times the rated current (peak value) for a duration of 8ms. Suited for transformer and lamp loads that draw steep inrush currents.
16,000
Inertia delay is available with time delay curves AD, MD, AA, BA, and MA.
Pulse
Width
12,000
(duration)
10,000
8,000
6,000
4,000
Circuit breakers equipped with inertia delay do not respond to high inrush currents such as
those produced by transformer, lamp, or motor loads, but perform specied interruption on
rated overcurrents.
Display Lights
Pulse Peak
Current
14,000
2,000
Specify inertia delay by inserting an F in the part number as shown in Part Number Guide on
previous page.
3 4 5 6 7 8
Pulse Width (ms)
10
x 100%
Timers
Notes
Multi-Pole
Multi-pole types such as 2- or 3-pole should be assembled by IDEC.
Because of their characteristics, 1-pole breakers cannot be combined to provide multi-pole units.
All multi-pole units are simultaneous break/simultaneous make, with levers mechanically interlocked.
Terminal Blocks
Circuit Breakers
USA: 800-262-IDEC
Canada: 888-317-IDEC
895
Circuit Breakers
NRBM Series
LINE
Display Lights
LINE
LOAD
LINE
NC
NO
NO
NC
LOAD
LOAD
Timers
DC
AC (50/60Hz)
Curve
100%
125%
150%
200%
400%
600%
800%
1000%
AA
No trip
15 120
8 45
3 15
0.48 2.5
0.06 0.8
0.007 0.13
0.005 0.04
BA
No trip
0.75 10
0.45 3.5
0.22 1.3
0.045 0.22
0.012 0.12
0.005 0.06
0.004 0.03
MA
No trip
70 900
30 260
10 70
1.8 11
0.5 4
0.009 1.1
0.006 0.2
AD
No trip
10 130
6 55
2.6 20
0.5 3.5
0.14 1.4
0.008 0.7
0.005 0.35
MD
No trip
35 400
20 180
8 60
1.6 10
0.6 4.5
0.01 2
0.007 0.5
Circuit Breakers
Terminal Blocks
896
www.idec.com
Circuit Breakers
NRBM Series
AC Time Delay Curves
1000
Curve AA
(at 25C)
Curve BA
(at 25C)
100
10
10
Time in sec
Time in sec
100
1000
0.1
0.01
0.01
300
400
500
600
700
800
900
1000
300
400
500
600
700
800
900
Display Lights
0.1
1000
1000
Curve MA
(at 25C)
100
Time in sec
10
0.1
0.01
300
400
500
600
700
800
900
1000
Timers
1000
Curve AD
(at 25C)
100
Terminal Blocks
10
Time in sec
10
Time in sec
Curve MD
(at 25C)
100
0.1
0.1
0.01
0.01
300
400
500
600
700
800
900
1000
USA: 800-262-IDEC
300
400
500
600
700
800
900
Circuit Breakers
1000
Canada: 888-317-IDEC
897
Circuit Breakers
NRBM Series
Coil Data
Curves
AD, MD
Curves
AA, BA, MA
1A
1.1
2A
0.227
0.245
3A
0.091
0.11
5A
0.035
0.039
7.5A
0.015
0.018
10A
0.0088
0.0124
15A
0.005
0.0065
20A
0.003
0.0047
25A
0.0023
0.0032
30A
0.0019
0.0031
40A
0.0018
0.002
50A
0.0014
0.0016
Curves AD and MD
10
0.1
0.01
0.0001
0.001
0.1
0.01
10
100
Resistance ()
100
10
0.1
0.01
0.001
0.01
0.1
10
100
Impedance ()
Circuit Breakers
Terminal Blocks
Timers
100
DC Resistance
898
www.idec.com
Rated
Current
Display Lights
Circuit Breakers
NRBM Series
Dimensions: NRBM Series
19.1
2-M3 screw
19.1
10.0
2-M3 screws
1-pole
2-pole
19.1
38.2
49.2
3.5
20.5
47.5
63.5
16.0
57.3
Display Lights
3-pole
60
NRBM
63.0
52.3
35.0
(2.8W 0.5t)
Panel Cut-Outs
NRBM Series
19.1
20.95
52.3
2-pole
1-pole
4 Mounting hole
35.5
19.1
26.15
9.8
19.6
38.7
3-pole
57.8
Timers
Terminal Blocks
Circuit Breakers
USA: 800-262-IDEC
Canada: 888-317-IDEC
899