Order Information Sheet (OIS)

FLT93F

1755 La Costa Meadows Drive | San Marcos, California 92078 USA


760-744-6950 Toll Free (US): 800-854-1993 Fax: 760-736-6250
www.fluidcomponents.com

General

FLT93F

Block No.

FlexSwitch Insertion for Flow, Level & Temperature

Sensor Element

Interconnecting
Cable

Control Circuit

10

11

12

13

14

15

INSTRUCTIONS: To order an FLT93F, please fill in each numbered box above with the appropriate code from the categories below. Once you have determined all the specifications, contact an FCI representative or
FCI directly for price information or additional options not shown. Consult FCI on the cost of special data and documentation. Final acceptance of the part number is subject to FCIs approval.
[Block 5]
Process Connection

[Block 1] Agency Approval Code


Not required

Factory Mutual (FM)

Factory Mutual (FM)


(T4 rated)1

ATEX, CE Marking

FMc

FMc (T4 rated)1

IEC 16

Inmetro

Other

[Block 2]
Identification Tag2
Mylar

-100F to 500F4, 29
[-73C to 260C]
[Block 4] All Welded
Material of Construction

Agency approved,
customer specified

W
*

[Block 6] Flange Size8, 9


Not required
10

300 lb carbon steel10


300 lb per Block 4

2 Flange
150 lb carbon steel10
Code
150 lb per Block 4
10
1 3 300 lb carbon steel
300 lb per Block 4
*

2
Code

316L stainless steel

316L stainless steel


electropolish

Code
0

1 1/2 Flange

-40F to 350F
[-40C to 177C]

Flanged

3 Other

A
B
C
D
E
F
G
H

Other

Flanged

Retractable Packing Gland


with Graphite Packing
Material 24

1 1/4 Male NPT

Flanged

(continued next column)

[Block 7] Insertion Length

Code

mm] 12

1
2
3
4
5
6
7
W

1.2 [30
2 [51 mm]
4 [102 mm]
3 6 [152 mm]
3 9 [229 mm]
12 [305 mm]
18 [457 mm]
3
Agency approved,
customer specified13
[Block 8]
Local Enclosure14

Low pressure
to 50 psig [3,5 bar(g)]

3
3 Single channel dual alarms
with standard epoxy sealed,
3 gold plated contacts 6 amp
3 at 115 Vac relays

Code

Sensor element only


with 6 [152 mm], Kapton
wire pigtails,
no enclosure

Sensor element only


with cable pigtail,
no enclosure15

[Block 10]
Alarm No. 1: Application18

A
C

3 Interface (wet / wet)


3 For Temperature Service
3 Temperature
3 [Block 11]
3 Alarm No. 2: Application9

D
E

For Flow Service


Gas

For Level, Interface Service


Wet / Dry

Agency approved,
customer specified18, 20

Aluminum;
NEMA Type 4X (IP66)
and hazardous locations
Groups B, C, D, E, F, G and EEx
d IIC; 2 x 3/4 + 1 1 entries

316 stainless steel;


NEMA Type 4X (IP66) and
3 hazardous locations Groups
B, C, D, E, F, G and EEx d IIC;
3 2 x 1 NPT entries 28

3
3

3
11.
12.
13.
14.

18.
19.

15.

17.

Agency approved,
customer specified

For Temperature Service


Temperature

16.

Interface (wet / wet)

6.
8.

10.

No enclosure; panel
mounted control circuit21

[Block 14] Cable Jacket

9.

(not recommended for


cable gland installation)

3
Not required
D 3

Agency approved,
customer specified22

4.
5.

for cable gland installation)

3 Other

1
3

Code

Aluminum;
NEMA Type 4X (IP66)
and hazardous locations
Groups B, C, D, E, F, G
and EEx d IIC; 2 x 1 NPT
entries (not recommended

50 [15 m]

*
1.
2.

Code

Not required

Code

Notes

Aluminum;
NEMA Type 4 (IP66)
and hazardous locations
Groups C, D, E, F, G with
opposing 2 x 1 NPT entries

Code

For Level, Interface Service


Wet / Dry

Not required

For Flow Service


Gas

Jumper selection, Air


flow curve from 0 SFPS
to 120 SFPS [36,6 NMPS]
and adjustment of 2 alarm
setpoints

[Block 13]
Remote Enclosure

[Block 9] Configuration 23 Code

Flat duct stainless steel


flange with 3/4 FNPT

adjustment of 2 alarm
setpoint in Air or Water

Other

#PN40, 316L stainless steel

Other

1 Male BSPT6

3 Agency approved,
3 customer specified
3 Other

3 Jumper selection and

hazardous locations
Groups B, C, D, E, F, G and
3 EEx d IIC; 1 x 1 NPT entry

Agency approved,
customer specified

Agency approved,
customer specified

1 Male NPT

316 stainless steel;

3 NEMA Type 4X (IP66) and

DIN DN50 Form C Flange


#PN16, 316L stainless steel

Agency approved,
customer specified 11

Aluminum;
NEMA Type 4X (IP66) and
hazardous locations Groups
B, C, D, E, F, G and EEx d IIC;
2 x 3/4 NPT entries

[Block 12]
[Block 15] Cable Length
Application-Specific Setup Code
& Calibration19
Not required
Not required
0 3 10 [3 m]
3 Jumper selection only
1 3 25 [7,5 m]
Jumper selection and
adjustment of 1 alarm
setpoint in Air or Water

3/4 Male NPT5

Single channel dual alarms


with hermetically-sealed,
0.5 amp at 115 Vac relays

1/4 Male NPT

Aluminum;
NEMA Type 4X (IP66)
and hazardous locations
Groups B, C, D, E, F, G and
EEx d IIC; 1 x 1 NPT entry

Monel 400

Code

Code

DIN DN40 Form C Flange


#PN40, 316L stainless steel

Hastelloy C

[Block 5] |
Process Connection

[Block 8]
Local Enclosure14
(continued from previous column)

3 150 lb carbon steel


3 150 lb per Block 4

[Block 3]
Process Temperature

1 1/4 Male NPT

316L stainless steel

Other

3
(continued from previous column)
3
Medium pressure
3 to 500 psig [35 bar(g)]

Code

Agency approved,
customer specified

Code

20.
21.

22.

Code

23.

PVC; 190F [90C]


maximum temperature

Teflon; 300F [150C]


maximum temperature

Agency approved,
customer specified

3
3

24.
28.
29.

Shorter manufacturing lead times are


available when this is selected in every
option.
Voids Agency Approvals. Contact FCI.
Field selectable heater power disabled.
Customer specified tag data field
maximum 3 lines by 20 characters/line
and must be supplied at time of order.
All other require a W or * in Block 2.
Not available with cable pigtail.
Only available in 316L stainless steel for
insertion lengths of 2 inches or greater.
Available in 316L stainless steel only.
ANSI flanges are phonographic
serrated, DIN are Form C per DIN 2526/
Form B1 per EN DIN1092-01.
Flanged material will be identical
to that selected in Block 4, Codes B,
D, F and H.
Carbon steel flanges are available with
316L stainless steel sensor construction
only.
Customer specified flange shall be per
ANSI or DIN specifications and must be
1 1/2[DN40] or larger.
For use only in a 3/4 tee.
Maximum insertion length is 120 inches.
Local enclosure required for agency
approval. Metal enclosure required for CE.
Select cable jacket and length in Blocks
14 and 15.
IEC approval: 350F [177C] maximum,
Block 3 must be Code 1. Local
enclosure,
Block 8 must be Code C, D or E. Remote
enclosure, Block 13, must be Code 0,
B, G or C.
Without 19 rack or mating connector.
Also available in dual channel version.
Refer to application matrix on
Application Data Sheet for valid alarm
combinations.
For all codes except 0 a completed
FLT application data sheet must
accompany the order.
Customer specified calibration shall
not exceed temperature and pressure
limitations of the FLT93F specifications.
Remote enclosure required for FM and
CSA approval.
Wire resistance must be less than 7.0
ohms.
Factory default setting for input power is
115 Vac for FM units, and 230 Vac for all
other agency approvals in Block 1.
Teflon packing material must be when
process media is Ozone, Chlorine or
Bromine.
Requires selection of stainless steel tag,
Code B in Block 2.
Electronics maximum temperature is
140F [60C]. If installation location
will exceed this, insulation, extending
the U length (Block 7) or remote
enclosure (Block 13) is recommended.

Note maximum cable temp:


PVC: 190F [90C]
Teflon: 300F [150C]
(continued next column)

Copyright 2014 Fluid Components International LLC. All rights reserved. Subject to change without notice. Order Information Sheet effective 01/2015

Doc. No. 01SA011304V

3
3
3

Application Data Sheet (ADS)

FLT93 F

1755 La Costa Meadows Drive | San Marcos, California 92078 USA


760-744-6950 Toll Free (US): 800-854-1993 Fax: 760-736-6250
www.fluidcomponents.com

FlexSwitch Insertion for Flow, Level & Temperature

Customer Information
Customer Name & Address: ___________________________________________
__________________________________________________________________
__________________________________________________________________

P.O. No.:_____________________

Customer Order: ____________________

Tag Number(s):

Contact: ___________________________________________________________
Phone: ___________________________

Fax: __________________________

Email: _____________________________________________________________

Control Circuit Jumper Section


Input Power:

c 115 Vac

c 230 Vac

Application Matrix
(Circle one alarm combination and enter in Blocks 10 - 11 on OIS)

Alarm 1
Alarm 2

Gas
Flow

Not required

A 0

Gas Flow

AA

Liquid
Flow

c 24 Vac

Temperature

Interface

C0

E0

D0

Contact Configuration: c SPDT



c DPDT (This selection disables Alarm No. 2)

DC

Alarm No. 2
Alarm Condition:
c Relay de-energized with low flow, low level (dry), or high temperature
c Relay de-energized with high flow, high level (wet), or low temperature

AC

CC

Interface

DD

Temperature

c 24 Vdc

Alarm No. 1
Alarm Condition:
c Relay de-energized with low flow, low level (dry), or high temperature
c Relay de-energized with high flow, high level (wet), or low temperature

Level
(Wet/Dry)

Liquid Flow
Level (Wet/Dry)

(Required for Block 12, Codes 3 through W of OIS)

AE

CE

EE

DE

Instrument Calibration

Contact Configuration: c SPDT (only)

(Required for Block 12, Codes 3 through W of OIS)

Part 1: Process Conditions


c Primary Flow Media: ______________________________________________

c Secondary Flow Media: ___________________________________________

c Lower Level Media: _______________________________________________

c Upper Level Media: ______________________________________________

c Gas

c Gas

c Liquid

c Liquid

Temperature: c F c C
Minimum __________ Nominal ___________ Maximum__________

Temperature: c F c C
Minimum __________ Nominal ___________ Maximum__________

Pressure: c Psig c Bar(g)


Minimum __________ Nominal ___________ Maximum__________

Pressure: c Psig c Bar(g)


Minimum __________ Nominal ___________ Maximum__________

Part 2: Calibration Conditions - Flow Applications Only


IMPORTANT: FCI calibrates in two medias; choose c Water or c Air
For Temperature Applications Only
Temperature Range
c As entered for the primary/lower media in the
Process Conditions section above.
c As entered for the secondary/upper media in the
Process Conditions section above.
c Other: __________________________________
Alarm Set Point:

No. 1 ______________________
No. 2 ______________________

Analog Output Curve: c Required


c Not required
Note: For vacuum and/or small volume (less than 10 in.3
or 150 cm3 ) process conditions, calibration of the temperature output is recommended if the temperature alarm is
used in combination with a flow or level/interface alarm.

For Flow Applications Only

For Level/Interface Applications Only

Pipe or duct inside diameter: _______________________ Sensing Element Mounting:



c inches c mm

Pipe Orientation:

c horizontal c vertical

Sensing Element Mounting: c side

c top

Flow Direction: c right to left


c left to right

c top to bottom c bottom to top

c Side
c Top

Level Rate-of-Change: _____________ c inches/sec


(at sensing element)
c mm/sec
Interface Rate-of-Change: ___________ c inches//hr
(at sensing element)
c mm/hr

Flow Range: minimum _________ maximum __________


Nominal Flow Rate: ____________________________ Output Bar Graph: c Required
c Not required
Flow Units: ___________________________________
Alarm Set Point: No. 1 __________ No. 2 __________
Analog Output Curve (per Block 11 on OIS):
c Air (see Code 8)
c Special (see Code W)
c Not required

Copyright 2014 Fluid Components International LLC. All rights reserved. Subject to change without notice. Order Information Sheet effective 01/2015

Doc. No. 01SA011304V