FLT93F
General
FLT93F
Block No.
Sensor Element
Interconnecting
Cable
Control Circuit
10
11
12
13
14
15
INSTRUCTIONS: To order an FLT93F, please fill in each numbered box above with the appropriate code from the categories below. Once you have determined all the specifications, contact an FCI representative or
FCI directly for price information or additional options not shown. Consult FCI on the cost of special data and documentation. Final acceptance of the part number is subject to FCIs approval.
[Block 5]
Process Connection
ATEX, CE Marking
FMc
IEC 16
Inmetro
Other
[Block 2]
Identification Tag2
Mylar
-100F to 500F4, 29
[-73C to 260C]
[Block 4] All Welded
Material of Construction
Agency approved,
customer specified
W
*
2 Flange
150 lb carbon steel10
Code
150 lb per Block 4
10
1 3 300 lb carbon steel
300 lb per Block 4
*
2
Code
Code
0
1 1/2 Flange
-40F to 350F
[-40C to 177C]
Flanged
3 Other
A
B
C
D
E
F
G
H
Other
Flanged
Flanged
Code
mm] 12
1
2
3
4
5
6
7
W
1.2 [30
2 [51 mm]
4 [102 mm]
3 6 [152 mm]
3 9 [229 mm]
12 [305 mm]
18 [457 mm]
3
Agency approved,
customer specified13
[Block 8]
Local Enclosure14
Low pressure
to 50 psig [3,5 bar(g)]
3
3 Single channel dual alarms
with standard epoxy sealed,
3 gold plated contacts 6 amp
3 at 115 Vac relays
Code
[Block 10]
Alarm No. 1: Application18
A
C
D
E
Agency approved,
customer specified18, 20
Aluminum;
NEMA Type 4X (IP66)
and hazardous locations
Groups B, C, D, E, F, G and EEx
d IIC; 2 x 3/4 + 1 1 entries
3
3
3
11.
12.
13.
14.
18.
19.
15.
17.
Agency approved,
customer specified
16.
6.
8.
10.
No enclosure; panel
mounted control circuit21
9.
3
Not required
D 3
Agency approved,
customer specified22
4.
5.
3 Other
1
3
Code
Aluminum;
NEMA Type 4X (IP66)
and hazardous locations
Groups B, C, D, E, F, G
and EEx d IIC; 2 x 1 NPT
entries (not recommended
50 [15 m]
*
1.
2.
Code
Not required
Code
Notes
Aluminum;
NEMA Type 4 (IP66)
and hazardous locations
Groups C, D, E, F, G with
opposing 2 x 1 NPT entries
Code
Not required
[Block 13]
Remote Enclosure
adjustment of 2 alarm
setpoint in Air or Water
Other
Other
1 Male BSPT6
3 Agency approved,
3 customer specified
3 Other
hazardous locations
Groups B, C, D, E, F, G and
3 EEx d IIC; 1 x 1 NPT entry
Agency approved,
customer specified
Agency approved,
customer specified
1 Male NPT
Agency approved,
customer specified 11
Aluminum;
NEMA Type 4X (IP66) and
hazardous locations Groups
B, C, D, E, F, G and EEx d IIC;
2 x 3/4 NPT entries
[Block 12]
[Block 15] Cable Length
Application-Specific Setup Code
& Calibration19
Not required
Not required
0 3 10 [3 m]
3 Jumper selection only
1 3 25 [7,5 m]
Jumper selection and
adjustment of 1 alarm
setpoint in Air or Water
Aluminum;
NEMA Type 4X (IP66)
and hazardous locations
Groups B, C, D, E, F, G and
EEx d IIC; 1 x 1 NPT entry
Monel 400
Code
Code
Hastelloy C
[Block 5] |
Process Connection
[Block 8]
Local Enclosure14
(continued from previous column)
[Block 3]
Process Temperature
Other
3
(continued from previous column)
3
Medium pressure
3 to 500 psig [35 bar(g)]
Code
Agency approved,
customer specified
Code
20.
21.
22.
Code
23.
Agency approved,
customer specified
3
3
24.
28.
29.
Copyright 2014 Fluid Components International LLC. All rights reserved. Subject to change without notice. Order Information Sheet effective 01/2015
3
3
3
FLT93 F
Customer Information
Customer Name & Address: ___________________________________________
__________________________________________________________________
__________________________________________________________________
P.O. No.:_____________________
Tag Number(s):
Contact: ___________________________________________________________
Phone: ___________________________
Fax: __________________________
Email: _____________________________________________________________
c 115 Vac
c 230 Vac
Application Matrix
(Circle one alarm combination and enter in Blocks 10 - 11 on OIS)
Alarm 1
Alarm 2
Gas
Flow
Not required
A 0
Gas Flow
AA
Liquid
Flow
c 24 Vac
Temperature
Interface
C0
E0
D0
DC
Alarm No. 2
Alarm Condition:
c Relay de-energized with low flow, low level (dry), or high temperature
c Relay de-energized with high flow, high level (wet), or low temperature
AC
CC
Interface
DD
Temperature
c 24 Vdc
Alarm No. 1
Alarm Condition:
c Relay de-energized with low flow, low level (dry), or high temperature
c Relay de-energized with high flow, high level (wet), or low temperature
Level
(Wet/Dry)
Liquid Flow
Level (Wet/Dry)
AE
CE
EE
DE
Instrument Calibration
c Gas
c Gas
c Liquid
c Liquid
Temperature: c F c C
Minimum __________ Nominal ___________ Maximum__________
Temperature: c F c C
Minimum __________ Nominal ___________ Maximum__________
No. 1 ______________________
No. 2 ______________________
c horizontal c vertical
c top
c Side
c Top
Copyright 2014 Fluid Components International LLC. All rights reserved. Subject to change without notice. Order Information Sheet effective 01/2015