Professional Documents
Culture Documents
User Manual
<Interference Cancellation System for WCDMA 5 Watt>
2010. 7
[ Table of Contents ]
1.
2.
System Specification............................................................................................ 13
Housing................................................................................................................ 17
Main features of
GUI ...................................................................................................................... 34
8.
7.3.10.
7.3.11.
8.1. Installation............................................................................................................ 51
8.1.1. Configuration................................................................................................... 51
8.1.2. Installation ....................................................................................................... 51
8.1.3. Check List before operation ............................................................................ 52
8.1.4. RF Monitor Port............................................................................................... 52
8.2. Process of ICS Repeater setup and installation .................................................. 53
Manufacturer Information..................................................................................... 56
[List of Figures]
[FIGURE - 1] SYSTEM NETWORK CONFIGURATION 1 ................................................... 11
[FIGURE - 2] SYSTEM NETWORK CONFIGURATION 2 ................................................... 11
[FIGURE - 3] NMS NETWORK CONFIGURATION.............................................................12
[FIGURE - 4] FRONT AND SIDE VIEW...............................................................................17
[FIGURE - 5] REAR VIEW...................................................................................................17
[FIGURE - 6] SYSTEM BLOCK PLAN.................................................................................18
[FIGURE - 7] SYSTEM EXTERNAL CONNECTORS..........................................................19
[FIGURE - 8] DOWN LINK/UP LINK ICM ............................................................................20
[FIGURE - 9] DONOR & SERVICE DUPLEXER .................................................................21
[FIGURE - 10] DOWN LINK PAU ........................................................................................22
[FIGURE - 12] POWER SUPPLY ........................................................................................23
[FIGURE - 13] INTERFACE.................................................................................................24
[FIGURE - 14] RCU VFD MENU TREE...............................................................................26
[FIGURE - 15] KEY-PAD......................................................................................................29
[FIGURE - 16] GUI MAIN WINDOW....................................................................................35
[FIGURE - 18] GUI COMMUNICATION SETUP..................................................................36
[FIGURE - 19] GUI COMMUNICATION STATUS WINDOW ...............................................36
[FIGURE - 20] GUI SYSTEM STATUS ................................................................................38
[FIGURE - 21] GUI PSU STATUS........................................................................................39
[FIGURE - 23] GUI DOWN LINK SETUP STATUS..............................................................40
[FIGURE - 24] GUI UP LINK SETTING STATUS ................................................................42
[FIGURE - 25] GUI WCDMA (3G) CONTROL WINDOW ....................................................43
[FIGURE - 26] FIRMWARE DOWNLOAD WINDOW...........................................................47
[ List of Tables ]
[TABLE - 1] RF SYSTEM SPECIFICATION.........................................................................14
[TABLE - 2] SYSTEM CONFIGURATION............................................................................16
[TABLE - 3] ENVIRONMENT SPECIFICATION...................................................................16
[TABLE - 4] MECHANICAL SPECIFICATION......................................................................16
[TABLE - 5] MODULES........................................................................................................18
[TABLE - 6] SYSTEM EXTERNAL CONNECTORS ............................................................19
[TABLE - 7] MECHANICAL SPECIFICATION......................................................................19
[TABLE - 8] INTERFACE FEATURES .................................................................................25
[TABLE - 9] RCU STATUS CONTROL DETAILS.................................................................29
[TABLE - 10] KEY FEATURE...............................................................................................29
[TABLE - 11] GUI PC REQUIREMENT................................................................................34
[TABLE - 12] REPEATER STATUS DETAILS ......................................................................37
[TABLE - 13] SYSTEM MONITORING ................................................................................38
[TABLE - 14] PSU MONITORING........................................................................................39
[TABLE - 16] DOWN LINK MONITORING...........................................................................40
[TABLE - 17] UP LINK MONITORING .................................................................................41
[TABLE - 18] SYSTEM CONTROL ITEM.............................................................................45
[TABLE - 20] DOWN LINK CONTROL ITEM .......................................................................46
[TABLE - 21] UP LINK CONTROL ITEM .............................................................................46
[TABLE - 20] SYSTEM CONFIGURATION..........................................................................51
[TABLE - 21] DC IN CONNECTOR PIN ASSIGN ................................................................51
[TABLE - 22] AC IN CONNECTOR PIN ASSIGN.................................................................51
[TABLE - 25] SYSTEM CONNECTION PORT.....................................................................52
1. System Overview
ICS-W0837B is a digital repeater that provides optimized service with ICS (Interference
Cancellation System) to make the most efficient way to enhance WCDMA network.
ICS-W0837B consists of the same construction as normal RF repeater except DSP
(Digital Signal Processing) part and it can overcome oscillation problem caused by lack of
the isolation level between donor and coverage antennas.
ICS-W0837B can automatically compensate rapidly-changing input signals including echo
feedback signals caused by multi-path environment and it has various advantages for
operation and maintenance.
ICS-W0837B consists of ICM (Interference Cancellation Module) that cancels feedback
signals, RF signal amplifier, MCU (Main Control Unit), and modem (optional) to operate with
NMS(Network Management System).
10
2. Network Configuration
2.1. Service for Network
ICS-W0837B can provide Cell Coverage to a Node-B with using PAU and it is for
expansion of WCDMA Cell Coverage.
The System Network Configuration of ICS-W0837B is shown as below
Wireless
Repeater
Repeater Cell
T1/E1
[Figure - 1] System Network Configuration 1
Wireless
Repeater
Repeater
Optic Fiber
Repeater Cell
T1/E1
11
Input level of ICS-W0837B is air interfaced with RF signal of WCDMA transferred from
Node-B and mobile through Donor and Service Antenna. The system consists of ICM that
cancels feedback signals, RF signal amplifier, monitoring and control processor, and
modem to operate with NMS (Optional).
The system has features that the Node-B RF signal through the donor antenna, ICM and
amplified by PAU of down link to pass the signals to service antenna. Also, it takes the
mobile input signal through service antenna, ICM and amplifier to pass the signals to donor
antenna. ICM consists of two parts, RF part and Digital part and ICM cancels feedback
signals for DL and UL. DL HPA consists of AMP block that amplifies RF signals and
Controller block that monitor and controls Amp block.
12
3. System Specification
3.1. System
3.1.1. WCDMA System Specification
Parameter
Down Link
Up Link
Number of Carrier
Frequency Range
Remark
1 Carrier
B1H, B1L
2 Carrier
B2
885MHz ~ 890MHz
840MHz ~ 845MHz
(Center: 887.5MHz)
(Center: 842.5MHz)
880MHz ~ 885MHz
835MHz ~ 840MHz
(Center: 882.5MHz)
(Center: 837.5MHz)
880MHz ~ 890MHz
835MHz ~ 845MHz
(Center: 885MHz)
(Center: 840MHz)
B1H
B1L
B2
3.84MHz (3.84MHz/Carrier)
B1H, B1L
8.84MHz (3.84MHz/Carrier)
B2
Band Width
Flatness
3dB p-p
-63dBm ~
-33dBm/Total
-50dBm/Total(Under)
Output Power
+37dBm/Total
+27dBm/Total
System Gain
70dB~100dB
70dB~100dB
30dB @1dB/Step
System Delay
< 8
Waveform Quality
EVM 12.5%
PCDE
< -35dB
Frequency Stability
< 0.01ppm
VSWR
< 1.5 : 1
@ Max Power
With 10 multi-path
feedback signal
13
Down Link
TX/RX Isolation
Noise Figure
Out-Band ACLR
Up Link
Remark
< 7dB
@Max. Gain
> 110dBc
-
45dBc @Fc5MHz
50dBc @Fc10MHz
2nd Harmonics
> 80dBc
Impedance
50ohm
14
Filter Type
Donor Antenna
Specification
Remark
Duplexer
MS3102A22S-2P(3Hole
male)_MIL-C-5015
TYPE
DC
- MS310A20-8P(6Hole male)_MIL-C-5015 TYPE
Size
weight
30Kg (Under)
Power Consumption
190W (Under)
Chasing level
IP56
Operation Temperature
-20C ~ +55C(95%RH)
Storage Temperature
-40C ~ +80C(95%RH)
OMC
Box panel for security of
repeater
Local/Remote Control
Optional (Mute be)
With bracket
Include Monitoring-Control-Alarm
NEBS
GR-63-
CORE Section4.1.2
NEBS
GR-63-
CORE Section4.1.2
NEBS
GR-63-
CORESection4.1.1
Proportional
USB Port at local, Modem(Option)
Remote Access
15
Under Windows
Include / one package
[Table - 2] System Configuration
Specification
Remark
AC Power
AC 90 ~ 264V
Consumption power
Under 190W
Operating Temperature
-20C ~ +55C
Operating Humidity
5% ~ 95%
Storage temperature
Ingress protection
IP65
[Table - 3] Environment Specification
Details
Size
Weight
Under 30Kg
Convection type
Natural convection
Mounting
Cabinet type
16
4. Housing
4.1. Housing Configuration
4.1.1. System
17
No.
Module Name
ICM
DUPLEXER (TOP)
PSU
[Table - 5] Modules
18
Name
Item
Specification
Size
Material
Cooling
Locks
Antenna
Port
Modem
Port
Ground
M5 2Hole
Environmental
Condition
19
5.1.1. ICM
20
5.2. Filter
It is 10MHz Band Pass Filter and consists of Service and Donor. Service Duplexer has
40dB Coupler to monitor Output power and Donor Duplexer has 30dB Coupler to monitor
Input power. Hence it can enable to measure the signal level and to observe its
specification.
21
22
23
5.5. INTERFACE
User can monitor and control the repeater by VFD and Keypad. Interface board consists
of 40Pin connector for communication with ICM, 16pin connector for communication with
Dual HPA, 24pin connector for communication with Interface board receives electrical
power from PSU and distributed the power to all of active module except Dual HPA. It also
can communicate with all of active module. Debug port is designed based on USB
connection
5.5.1. INTERFACE
POWER
INTERFACE
VFD
HPA
INTERFACE
KEY-PAD
USB
MODEM ANTENNA
PORT
LED
BLUETOOTH ANTENNA
PORT
ICM
INTERFACE
Term
Feature
VFD
KEY-PAD
LED
Modem Ant.
Bluetooth Ant.
USB
Power Supply
PSU Status
24
25
5.5.2. VFD
5.5.2.1.
26
5.5.2.2.
Details
Fwd Status
ICS
Remark
: [Normal]
Fwd Status
OUTPWR : 000dBm
Fwd Status
INPWR
: -000dBm
Fwd Status
ISO.
FWD Status
: 000dB
Fwd Status
GAINMODE : [GAIN]dB>
Fwd Status
GAIN
ATTN
[OFF]/[GAIN]
Down Link GAIN Setup Mode
: [Normal]
Rvs Status
ICS
: [Normal]
Fwd Status
LOW
: 000dB>
Fwd Status
HIGH
: 000dB>
Fwd Status
RVS Status
: [Normal]
Rvs Status
OUTPWR : 000dBm
Rvs Status
INPWR
: -000dBm
Rvs Status
ISO.
: 000dB
Rvs Status
GAINMODE : [GAIN]dB>
Rvs Status
GAIN
: 000dB>
27
: 000dB>
Rvs Status
BAL
: 000dB>
Rvs Status
HIGH
: [Normal]
VSWR
: [NORMAL]
: [NORMAL]
Environment
Amp
Mode
: [ ON ]>
: [ON]>
Environment
DOOR
: [NORMAL]
Environment
BATT
: [NORMAL]
Environment
DC
: 000
Environment
AC
: [OPEN]
Environment
TEMP
: [NOTUSE]>
Environment
FAMODE : [MANUAL]>
Environment
FAN
: [MANUAL]>
28
: [RESET]>
Environment
SLANT
: [NORMAL]>
5.5.3. KEY-PAD
M enu
Up
D ow n
E nter
ESC
KEY-PAD uses 5 keys as above. Each meaning and operation is as below. The setup
Mode is only in P#02 and it can change a mode by setup.
In P#02, a menu which can be setup is displayed as >
Key
Menu
Up
Down
Enter
Esc
Step
Status Mode
Setup Mode
P#00
Move to P#01
N/A
P#01
Move to P#00
N/A
P#02
Move to P#00
Move to P#00
P#00
N/A
N/A
P#01
N/A
P#02
On or Increase
P#00
N/A
N/A
P#01
N/A
P#02
Off or Decrease
P#00
N/A
P#01
Move to P#02
N/A
P#02
Setting Value
P#00
N/A
N/A
P#01
Move to P#00
N/A
P#02
Move to P#01
Cancel setiting
29
6.1.2. Procedure
CPU (in ICM) performs download remotely through TCP/IP function of modem installed in
a repeater.
6.2.2. Procedure
1. Gain setup mode
1) User can set up Gain within a certain range.
Down Link : 70B ~ 100B
Up Link : 70dB ~ 100dB
2) Gain should be set up according to ICS repeater input condition.
(ex) When input is -40dBm, Gain can be over Max. 67 dB because ICS repeater
output cannot be over 37dBm)
3) When the Gain is less compared to Isolation, ICM set Attenuator. to optimized
value in order to protect the system, and CPU occurs alarm and displays
Isolation deficient
When Isolation is back to normal, Gain return to the previous set-up and
Isolation deficient alarm is removed
2. OFF Mode
1) This can be established at the initial set-up or special occasion. When OFF mode,
Attenuator is set up to Maximum in order to protect the system
3. Gain Balance Mode
1) Up Link Gain is set up automatically as low as Gain Balance set-up value
compared to Down Link current Gain
30
2) Gain Balance set-up range is 0 ~ 10dB and this mode can be set up at the Up
Link
6.2.3. Others
At the initial execution, if Gain set-up is not executed normally, it is notified to the user and
holds the default Attenuator value
6.3.2. Procedure
1. Total Power Limit does not have additional operation Mode and it works based on
max. output power value set up by user
1) Down Link Output Power set-up Range : ~ 38dBm/Total
2) Up Link Output Power set-up Range : ~ 28dBm/Total
2. Total Power Limit operating point: monitored value max. output power set-up value
3. Total Power Limit Attenuator operating: After Down Link Attenuator change, turn down
Attenuator. To be 1 dB less than max. output power set-up value
1) The changed Attenuator. value should be stored in the system
2) When the changed Attenuator. value is reset
RCU Reset
Change User Attenuator. Value before changed Attenuator. value restored
4. Total Power Limit Restoration Point: Down Link Attenuator restoration condition is to
restore by 1 dB Step from 3 dB less than max. output power set-up value
5. Total Power Limit Restoration Attenuator operation: restore Attenuator. up to the value
of max. output power set-up value: 2
6. Restore preferentially the changed Attenuator. value
31
6.4.2. Procedure
1. When Dual HPA is shutdown caused by over power until Down Link Path is in service
normally, CPU (in ICM) detects HPA shutdown and checks Down Link input level as
well as the gain right before the shutdown.
2. Dual HPA(in Down Link Path) Shutdown condition on Re-Check
1. When Down Link Input Level + Gain right before Shutdown System output
power + 1dBm
Over Power Alarm on
9 Recovery Condition
2. When Down Link Input Level + Gain right before Shutdown System output
power
Over Power Alarm off
6.5.2. Procedure
1. It is operated by Auto Shutdown mode
2. If Down Link output power is OFF, then it turns off Up Link output power (except
turning off by user)
3. When Up Link output power is OFF, it executes Amp Off alarm and reports Reason
4. If Down Link output power is ON by Auto Recovery feature, then Up Link output
power is ON as well
32
33
7. GUI
7.1. Program Overview
This software provides status, control, download, and cancellation of ICS repeater. It is
easy to use with PC or laptop to install this program and to check a status of repeater for
users.
7.2. PC Requirement
Recommended
Item
Minimal Requirement
CPU
Pentium-3 500Mhz
Pentium-3 500Mhz
Memory
128 MB
128MB
Operating System
Windows 2000
Windows 2000
USB
essential
essential
Resolution
800X600
1024X768
Program Size
1M
Requirement
1M
34
35
7.3.3.1.
Set up
To setup Communication, repeater control, download, packet check, signal search and
communication cycle
7.3.3.2.
Status check
Communication Status
Connection
If the port is already occupied and can not be used, it gives Warning Windows with
warning and error message.
7.3.4.2.
Disconnection
36
Status
Red
Alarm status
Green
Normal status
Gray
Initial Status
Values
On/Off
Remark
System
Item
Details
Remark
ICS Maker
Repeater manufacturer
Supplier
Repeater supplier
Modem Maker
Modem manufacturer
Amp Maker
Version
Temperature
Repeater Temperature
Over Temp
Alarm/Normal
Door Open
Door status
Alarm/Normal
37
Auto Shutdown
Auto Recovery
38
7.3.6.2.
PSU
Item
Status
Remark
AC Fail
Alarm/Normal
DC Fail
Alarm/Normal
Battery S/W
Alarm/Normal
UPS Status
Alarm/Normal
Low Battery
Alarm/Normal
On Battery
Alarm/Normal
7.3.6.3.
Down Link
Item
Description
Remark
Over Temp
Alarm/Normal
DC Fail
Amp DC on/off
Alarm/Normal
VSWR
Amp VSWR
Alarm/Normal
Loop Fail
Amp Loop
Alarm/Normal
Device Fail
Amp Device
Alarm/Normal
Over Power
Alarm/Normal
Amp On/Off
Amp On/Off
Amp Temp
Output Power
Input Power
Output Upper
Alarm/Normal
Output Lower
Alarm/Normal
Input Upper
Alarm/Normal
Input Lower
Alarm/Normal
RF Device
Attenuation
Attenuation Status
39
Alarm/Normal
ICS Status
Cancellation Status
Alarm/Normal
Isolation Lack
Isolation lack
Alarm/Normal
Sys Isolation
System Gain
ICS Mode
Target Gain
40
7.3.6.4.
Up Link
Item
Description
Remark
VSWR
Alarm/Normal
Device Fail
Alarm/Normal
Over Power
Alarm/Normal
Amp On/Off
Output Power
Input Power
Output Upper
Alarm/Normal
status
Input Upper
RF Device
Attenuation
DSP Link
Alarm/Normal
ICS Status
Cancellation Status
Alarm/Normal
Isolation Lack
Alarm/Normal
Sys Isolation
System Gain
ICS Mode
Target Gain
Balance Offset
Total Power Limit
Alarm/Normal
41
Control Mode
42
7.3.7.2.
System Control
By checking the Auto Shutdown, In Power Mode, Auto Recovery to turn on each
function and un-checking the items to turn off.
Input the value and press the enter key to setup Temp upper.
To make sure, information window will be displayed before the command is executed.
Click OK to setup.
Click Cancel to cancel setup.
7.3.7.3.
Band Selection
43
.
Click OK to setup.
7.3.7.4.
FA Control
Check the box to ON and uncheck the box to OFF for FA and after finish checking, click
Apply to setup.
FA Allocation is set up when select Manual or Auto.
To make sure, information window will be displayed before the command is executed.
.
Click OK to setup.
Click Cancel to cancel setup.
7.3.7.5.
By checking the box, Amp On/Off, Total Power Limit items will be ON and by unchecking the box the items will be off.
Output Upper, Output Lower, Input Upper, Input Lower, Attenuation, Gain Level input
the value and press the Enter key to setup.
I For the ICS mode, simply select the item and will be set up.
To make sure, information window will be displayed before the command is executed.
44
Up Link Control
By checking the box, Amp On/Off, Total Power Limit items will be ON and by unchecking the box the items will be off.
Output Upper, Input Upper, Attenuation, Gain Level, Gain Balance Offset input the
value and press Enter key to setup.
Select the item to setup ICS Mode.
To make sure, information window will be displayed before the command is executed.
Click OK to setup.
Click Cancel to cancel setup.
System
Item
Description
Temp High
Auto Shutdown
In Power Mode
Auto Recovery
Remark
45
Down Link
Item
Description
Remark
Amp On/Off
Amp On/Off
Output Upper
Output Lower
Input Upper
Input Lower
Attenuation
ICS Mode
Gain Level
7.3.8.3.
Up link
Item
Description
Remark
Amp On/Off
Amp On/Off
Output Upper
Input Upper
Attenuation
ICS Mode
Gain Level
Balance Offset
Download
46
7.3.9.2.
How to Download
47
Data Debugging
7.3.10.1.
Debugging
7.3.10.2.
How to Debugging
7.3.11.
7.3.11.1.
48
Manual Request
Automatic Request
49
50
Specification
Repeater Cabinet
ICS-W2137
DC IN Connector
MS310A20-8P(6Pin male)
AC IN Connector
MS3102A22S-2P(3Pin male)
Quick manual
User Manual
DC IN Connector
MS310A20-8P(6Pin male)
Pin A : +27V
Pin B : EXT_+5V(Not use)
Pin C : EXT_GND(Not use)
Pin D : GND
Pin E : EXT_RX(Not use)
Pin F : EXT_TX(Not use)
[Table - 21] DC IN Connector Pin Assign
AC IN Connector
MS3102A22S-2P(3Pin male)
Pin A : HOT
Pin B : NUT
Pin C : GND
8.1.2. Installation
-
Ground repeater
Verify if Main Power LED if the connection is correct (Extension code can be used if
51
Function
DC IN
A: +27V
D: GND
AC IN
A : AC 100V~260V+
B : AC 110V~260V-
Modem Port
WCDMA Tx/Rx
Donor Port
TX Input / RX Output
Service Port
TX Output / RX Input
C : GND
Verify if all the connections are correct including Power Cable, RF Cables, Ground
and so on.
Verify if each module power and data cable have correct connection
Service Antenna
TX(To BTS)
RX(from BTS)
TX(To Mobile)
RX(From Mobile)
15 dB Coupling
30 dB Coupling
40 dB Coupling
52
53
Alarm
High Input
Power
( DL / UL )
Alarm Status
Alarm : Red
Normal : Green
Low Input
Power
RF
( DL )
Alarm : Red
Normal : Green
Power
RF Cables in Repeater,
Input level to ICS module
Replace cables, adjust ANT direction
High Output
Power
( DL / UL )
Low Output
Power
( DL )
Alarm : Red
Normal : Green
Alarm : Red
Normal : Green
ICS (DSP)
Alarm : Red
( DL / UL )
Normal : Green
Over Power
Alarm : Red
( DL )
Normal : Green
DL
High Temp.
Alarm : Red
PAU
( DL )
Normal : Green
VSWR
Alarm : Red
( DL )
Normal : Green
RF
RF Device
Alarm : Red
Device
( DL / UL )
Normal : Green
ICS
Antenna Direction,
54
PAU
Alarm : Red
PAU
( UL )
Normal : Green
Alarm Status
Door Open
Alarm : Red
Alarm
Normal : Green
AC Alarm
DC Alarm
Housing
Temp
Alarm
Alarm : Red
Normal : Green
Alarm : Red
Normal : Green
Alarm : Red
Status,
DOOR
SW
Remark
operation
Check
DOOR Lock and Updating SW
Verify AC Voltage
Re-construct AC Power
Verify if PSU output is 27V
Replace PSU
Verify Housing Temp.
Normal : Green
[Table - 26] Environment Alarm
55
9. Manufacturer Information
RF Window co. ltd.
Maker : RF Window Co., Ltd
Address: 14F, Daerung Posttower3, 182-4, Guro-3dong, Gurogu, Seoul, 152-847, South Korea
TEL: +82 2- 2082-1250
56