You are on page 1of 4

Funciones standar de operacin

Funciones Bsicas

Funciones

Nm
Parm

Nombre

0
1
2
3
4
5
6

Torque de Impulso
Frecuencia Mxima
Frecuencia Mnima
Frecuencia Base
Multi-speed setting (high speed)
Multi-speed setting (middle speed)
Multi-speed setting (low speed)

Tiempo de aceleracin

Tiempo de desaceleracin

Electronic thermal O/L relay

10
11
12
13
14
15

Dc injection brake operation frecuency

16

Jog acceleration / desaceleracin time

17
18
19

MRS input selection


High-speed maximun frecuency
Base frecuencia voltaje
Acceleration/deceleration reference
frecuency
Acceleration/deceleration time
increments
Stall prevention operation level
Stall prevention operation level at
double speed
Multi-speed setting (speed 4)
Multi-speed setting (speed 5)
Multi-speed setting (speed 6)
Multi-speed setting (speed 7)
Multi-speed input compensation
Acceleration/deceleration pattern
Regenerative function selection
Frequency jump 1A
Frequency jump 1B
Frequency jump 2A

20
21
22
23
24
25
26
27
28
29
30
31
32
33

Dc injection brake operation time


Dc injection brake voltaje
Starting frecuency
Load pattern selection (Note1)
Jog Frecuency

Setting Range

0 a 30 %
0 a 60 Hz
0 a 120 Hz
0 a 400 Hz
0 a 400 Hz
0 a 400 Hz
0 a 400 Hz
0 to 3600 seg
0 to 3600 seg
0 to 3600 seg
0 to 3600 seg
0 to 3600A
0 a 120 Hz, 9999
0 a 10 sec, 8888
0 a 30 %
0 a 60 Hz
0a5
0 a 400 Hz
0 a 3600 seg
0 a 360 seg
0,2
0 a 400 Hz
0 a 1000V, 8888, 9999

1 a 400 Hz
0,1
0 a 200%, 9999
0 a 200%, 9999
0 a 400 Hz, 9999
0 a 400 Hz, 9999
0 a 400 Hz, 9999
0 a 400 Hz, 9999
0,1
0,1,2,3
0,1,2
0 A 400 Hz, 9999
0 A 400 Hz, 9999
0 A 400 Hz, 9999

Output
terminal
functions

34
35
36
37
41
42
43

Frequency jump 2B
Frequency jump 3A
Frequency jump 3B
Speed display
Up-to-frequency sensibilidad
Output frequency detection
Output frequency detection for
reverse rotation

44

Second acceleration/desaceleracin time

45

Second desaceleracin time

46
47
48
49
50

Second torque boost (Note 1)


Second V/F (base frecuencia)(Note 1)
Second stall prevention operation current
Second stall prevention operation frecuencia

Second output frecuencia detection

0 A 400 Hz, 9999


0 A 400 Hz, 9999
0 A 400 Hz, 9999
0,1 a 9998
0 a 100%
0 a 400 Hz
0 a 400 Hz, 9999
0 to 3600 seg
0 to 360 seg
0 to 3600 seg/0 to 360

sec, 9999
0 to 30%, 9999
0 to 400 Hz, 9999
0 to200%
0 to 400 Hz, 9999
0 to 400 Hz

Incremento
Factor de Ajust.
Seteo Mn.
0,10%
1%
0,01 Hz
60 Hz
0,01 Hz
0 Hz
0,01 Hz
60 Hz<50Hz>
0,01 Hz
60 Hz
0,01 Hz
30 Hz
0,01 Hz
10 Hz
0,1 seg
15 seg
0,01 seg

Pgina

Valor en VDF

Unidad

48
49
49
49
50
51
51

0,5
50
25
50
50
30
10

%
Hz
Hz
Hz
Hz
Hz
Hz

52

segundos

52

180

segundos

53

168

54
54
54
55
56
56

3
0,5
1
0,5
0
5

Hz
segundos
%
Hz

0,5 Seg

56

0,5

segundos

0
60 Hz
9999<8888>

57
57
57

0
50
9999

Hz
V

0,01 Hz

57

50

57

0,10%

150%(CT)/120%(VT)

58

150

0,10%

9999

58

9999

0,01 Hz
0,01 Hz
0,01 Hz
0,01 Hz
1
1
1
0,01 Hz
0,01 Hz
0,01 Hz

9999
9999
9999
9999
0
0
0
9999
9999
9999

59
59
59
59
59
60
61
62
62
62

9999
9999
9999
9999
0
0
0
9999
9999
9999

Hz
Hz
Hz
Hz

0,1 A
0,1 A
0,01 Hz
0,1 sec
0,10%
0,01 Hz
1
0,01 Hz
0,1 Seg.
0,01 Seg.
1
0,01 Hz
0,1 V

15 seg
Rated output
current
3 Hz
0,5 Seg
1%
0,5 Hz
0
5 Hz

Ref.

Hz

Hz

Hz
Hz
Hz

0,01 Hz
0,01 Hz
0,01 Hz
1
0,10%
0,01 Hz

9999
9999
9999
0
10%
6Hz

0,01 Hz

9999

0,1 seg/0,01
5 segundos
seg
0,1 sec/ 0,01
9999
sec
0,10%
9999
0,01 Hz
9999
0,10%
150% (CT)/120%(VT)
0,01 Hz
0
0,01 Hz
30 Hz

62
62
62
63
64
64
64
64

9999
9999
9999
0
10
6

Hz
Hz
Hz

9999

Hz

65

segundos

66

9999

segundos

65
65
65
65
66

9999
9999
150
0
30

%
Hz
%
Hz
Hz

%
Hz

You might also like