Professional Documents
Culture Documents
www.huawei.com
Foreword
OptiX RTN 600 is a PDH/SDH integrated short-haul digital
microwave transmission system developed by Huawei.
The maximum microwave transmission capacity is STM-1.
The system provides the backhaul transmission link in the
mobile communication system or private network, and also
networks with optical transmission equipments.
Page 1
References
z
Page 2
Objectives
z
Page 3
Contents
1. Equipment Overview
2. Equipment Structure
3. Equipment Protection
Page 4
Contents
1. Equipment Overview
IDU
ODU
Antenna
Hybrid coupler
Page 5
Equipment Components
Antenna
Hybrid coupler
IF cable
ODU
IDU
Pole
Page 6
IDU
z
IDU 610
IDU 620
Page 7
IF Cable
z
The IF cable provides -48V power for ODU and transmits the IF signal
and ODU management signal between IDU and ODU.
Three types of IF cable in OptiX RTN 600:
RG-8U (1/4 inch) cable is used for the distance less than 180 meter.
1/2 inch cable is used for the distance between 180m and 300m.
IF transit jumper
IF cable
Page 8
ODU
z
Page 9
Hybrid Coupler
z
When two ODUs share one antenna, the ODUs must be connected to
an RF signal coupler/ splitter (hybrid coupler). Then, the hybrid
coupler is connected to the antenna.
Page 10
Antenna
z
Page 11
Equipment Characteristics
z
The modulation mode and link capacity are set through software.
The boards of IDU 610 and IDU 620 are compatible each other.
Page 12
Questions
z
What are the components of OptiX RTN 600? What are the functions
of them? What about the connection relation among the components?
Page 13
Contents
1. Equipment Overview
2. Equipment Structure
3. Equipment Protection
Page 14
Contents
z
Equipment Structure
Page 15
System Diagram
z
Service
interface
unit
Antenna
Baseband
signal
Crossconnect
unit
Baseband
signal
RF
signal
IF signal
IF unit
ODU
Order wire
External alarm
Transparent data
interface
Auxiliary
interface
unit
Clock unit
External clock
or WS signal
Control unit
Fan and
power
supply unit
NM network
port
NM serial
NM cascading
port
network port
Page 16
Software Structure
z
NM software
Host software
Board software
ODU
SCC
Page 17
Contents
z
Equipment Structure
Page 18
IF board
EXT
slot3
EXT
slot4
PXC
slot1
SCC
slot2
Page 19
slot
20
EXT
slot7
EXT
slot8
EXT
slot5
EXT
slot6
PXC
slot3
EXT
slot4
PXC
slot1
SCC
slot2
Page 20
IF cable interface
ODU power
supply switch
Indicators
Page 21
IF Board -- Types
IF1B
IF1A
grounding modes.
Page 22
Recommended
installation
sequence for IF
boards
Paired Slots
Paired Slots
EXT
slot3
EXT
slot4
PXC
slot1
SCC
slot2
IDU 610
EXT
slot7
EXT
slot8
slot EXT
20
PXC
slot5
EXT
slot6
slot3
EXT
slot4
PXC
slot1
SCC
slot2
IDU 620
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 23
IF interface Combiner
interface
unit
IF
process
unit
Modem
unit
MUX /
DEMUX
unit
TUPP
unit
Crossconnect
active/
standby
unit
Control bus
Power
unit
Clock
unit
Support
loop-back
function
Logical control
unit
Page 24
Backplane
Paired
slots
SCC board
SMODEM unit
IF interface Combiner
interface
unit
Analog IF
signal
IF
process
unit
Modem
unit
Digital IF
signal
Baseband
digital
signal
Page 25
The first 2M
overhead signal
Modem
unit
SDH microwave
frame signal
MUX /
DEMUX
unit
Clock signal
Cross-connection
and clock board
TUPP unit
Detecting LINKID, ATPC,
and microwave RDI
information
Page 26
SCC board
Modem
unit
PDH microwave
frame signal
MUX /
DEMUX
unit
Clock signal
Cross-connection
and clock board
TUPP unit
VC4 signal
Page 27
Modem
unit
two signals
have the phase
difference.
MUX /
DEMUX
Unit
On
Standby
IF board
MUX / DEMUX
unit
Local board
Microwave signal
TUPP
unit
Standby board
Microwave signal
2 signals are
synchronized
Page 28
TUPP unit
VC4 service
Crossconnection
active/
standby
unit
Active
crossconnection
board
Standby
crossconnection
board
Page 29
Clock
System clock used
by local board
Service
Active
crossconnection
clock board
VC4 signal
MUX /
DEMUX
unit
Clock
High-order pointer
signal C1J1
Service
Standby
crossconnection
clock board
Cross-connection
active/standby unit
Page 30
2M overhead
SCC
board
2M overhead wayside E1
Modem
unit
SDH microwave
frame signal
MUX /
DEMUX
unit
VC4 signal
High-order
pointer signal
Crossconnection
active/
standby
unit
Page 31
Modem
unit
PDH microwave
frame signal
1x 2M overhead
MUX /
DEMUX
unit
VC4 signal
SCC
board
Crossconnection
active/
standby
unit
Page 32
Serial port
signal
IF
interface Combiner
interface
unit
-48V power
supply
SCC
board
SMODEM unit
IF
process
unit
IF analog
signal
IF digital
signal
Modem
unit
Baseband
digital signal
Page 33
IF Board -- IF Performance
Performance
Item
4 X E1
8 X E1
16 X E1
Modulation
mode
QPSK
16QAM
QPSK
16QAM
Channel
spacing
(MHz))
3.5
13.75 /14
a
Coding
scheme
Remarks
STM-1
QPSK
16QAM
128QAM
27.5/
13.75 /14
a
27.5 / 28 b
28 b
Page 34
IF signal
ODU
management
signal
Performance
Transmitting frequency
(MHz)
350
140
Impedance (ohm)
50
Modulation mode
ASK
Transmitting frequency
(MHz)
5.5
10
Page 35
IF Board -- Indicators
Indicator
STAT
SRV
LINK
Status
Meaning
On
On
Off
On
On
On
Off
On
On
Page 36
IF Board -- Indicators
Indicator
ODU
BER
Status
On
On
On
Off
On
Off
On
Off
RMT
ACT
Meaning
Page 37
Indicator
1-8 channel E1
DB44 interfaces
9-16 channel E1
DB44 interfaces
Page 38
PO1A
PH1B
16-channel E1
interface
8-channel E1
interface
16-channel E1
interface
75 ohm
75 ohm
PO1B
120 omh
Four groups of
jumpers
determine the
impedance.
8-channel E1
board
Page 39
120 ohm
EXT
slot3
EXT
slot4
PXC
slot1
SCC
slot2
IDU 610
EXT
slot7
EXT
slot8
slot EXT
20
PXC
slot5
EXT
slot6
slot3
PXC
slot1
EXT
SCC
slot4
slot2
IDU 620
Page 40
E1
interface Tributary
interface
unit
Coding
and
decoding
unit
Mapping/
De-mapping
unit
Cross
-connect
active/
standby
unit
Control bus
Clock
unit
Support loop-back
function
Logical
control
unit
Page 41
STAT
SRV
Status
Meaning
On
On
Off
On
On
On
Off
Page 42
The line board processes 1-2 channel STM-1 signal and provides
STM-1 optical or electrical interface.
LC optical
interface
SMB
electrical
interface
Page 43
Dual-port STM-1
optical interface
SL1
optical interface
Ie-1
S-1.1
L-1.1
L-1.2
interface interface interface interface
Ie-1
S-1.1
L-1.1
L-1.2
interface interface interface interface
SDE
SLE
dual-port STM-1
electrical interface
Single-port STM-1
electrical interface
Page 44
EXT
slot3
EXT
slot4
PXC
slot1
SCC
slot2
IDU 610
EXT
slot7
EXT
slot8
slot EXT
20
PXC
slot5
EXT
slot6
slot3
PXC
slot1
EXT
SCC
slot4
slot2
IDU 620
Page 45
Optical
interface
O/E
converter
unit
Overhead bus
Overhead
process
unit
TUPP
unit
Crossconnect
active/
standby
unit
Control bus
Clock
unit
Logical
control
unit
Page 46
Performance
155520
Application code
Ie-1
S-1.1
L-1.1
L-1.2
Multimode fiber
G.652
G.652
G.652
0.5
15
40
80/100
1260-1360
1261-1360
1263-1360
1480-1580
19~14
15~8
5~0
5~0
-23
-28
-34
-34
-14
-8
-10
-10
8.2
8.2
10
10
Page 47
SRV
LOS1
LOS2
Status
Meaning
On
On
Off
On
On
On
Off
On
Off
On
Off
Page 48
EXT
slot3
EXT
slot4
PXC
slot1
SCC
slot2
IDU 610
EXT
slot7
EXT
slot8
slot EXT
20
PXC
slot5
EXT
slot6
slot3
PXC
slot1
EXT
SCC
slot4
slot2
IDU 620
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 49
The PXC board realizes the cross-connection (1616 VC4) and clock
functions , it also provides the DC power for other boards.
Power input
interface
IDU
Power
switch
External clock/
Wayside
interface
Indicator
Page 50
slot3
EXT
slot4
PXC
slot1
SCC
slot2
IDU 610
EXT
slot7
EXT
slot8
EXT
slot5
EXT
slot6
PXC
slot3
PXC
slot1
EXT
SCC
slot4
slot2
slot
20
IDU 620
Page 51
External clock/
wayside E1
interface
Clock
unit
External
clock
unit
Cross
-connect
unit
Overhead bus
Control bus
Logical
control
unit
External -48V
power
System
power
unit
48V
System power supply
Page 52
Cross
-connect
wayside E2 board
IF board
IF board
IF board
IF board
Page 53
PXC -- Indicators
Indicator
STAT
PWR
SYNC
ACT
Status
Meaning
On
On
Off
On
On
Off
No input power.
On
On
On
Off
Page 54
Flash
memory
Indicators
NM
interface
Indicator
test button
NM serial
port
Reset
button
Order wire
Asynchronous
data and
Boolean
interface
NM cascaded
interface
Page 55
slot3
slot1
EXT
SCC
slot4
slot2
EXT
EXT
slot8
slot6
EXT
SCC
slot4
slot2
IDU 610
slot
20
EXT
slot7
EXT
PXC
PXC
slot5
slot3
slot1
IDU 620
Page 56
Backplane
Auxiliary
interface
Boolean interface unit
NM interface
HUB
Cascaded network
port
NM serial port
Control
comm.
unit
Control bus
System
power
unit
48V
System power supply
Page 57
The SCC board sets the NE ID through the software. The initial NE ID is set
to 49136 by default.
The IP address of NE is also set through the software. The IP address is set
to 129.9.0.ID by default.
NMS
Connected by
Ethernet cable
Page 58
The connection
will cause NE
reset frequently.
Page 59
When the IF board is changed from STM-1 mode to PDH mode, if the
transparent transmission setting of DCC byte occupies the D1 byte,
the manual modification is required. Set the working mode to DI
mode first. Otherwise, when the IF board is changed to the PDH
mode, the DCC is interrupted.
Page 60
STAT
PROG
Status
Meaning
On
On
Off
On
Page 61
Status
On
Off
On
On
On
Off
On
Off
PROG
ALM
Meaning
MANT
Page 62
EXT
EXT
PXC
PXC
slot
20
slot7
EXT
slot5
EXT
EXT
slot3
slot1
SCC
Fan direction
Indicator
FAN
Status
slot8
slot6
slot4
slot2
Meaning
On
On
Off
Page 63
Contents
z
Equipment Structure
Page 64
ODU -- Interface
Grounding
double-screw bolt
RSSI test
interface
IF interface
Antenna
port
Page 65
Amplifier
IF interface
Up
conversion
Amplifier
Antenna port
IF
interface
unit
Frequency
synthesizer
Amplifier
Down
conversion
Duplexer
Amplifier
Power
unit
Page 66
Item
Performance
7G
15G
18G
23G
14.501-
17.685-
22.000-
15.257
19.710
23.608
1010
1008
Frequency range
(GHz)
7.114-7.743
TR spacing (MHz)
161
420
Channel spacing
(MHz)
3.5, 7, 14,
28
3.5, 7, 14,
3.5, 7,
28
13.75, 27.5
Page 67
3.5, 7, 14, 28
Item
maximum Tx (dBm)
7G
15G
18G
23G
QPSK
25.5
24.5
24
22.5
16QAM
21
20
20
19
128QAM
15
14
14
13
minimum Tx (dBm)
-4
Transceiver frequency
stability (ppm)
[Note]: If the transmitting power exceeds the maximum level ,the Bite
Error will occur in the service.
Page 68
Contents
z
Equipment Structure
Page 69
Hybrid coupler
Page 70
Performance
Flatness (dB)
0.5
Attenuation (dB)
1.7
Coupling (dB)
6.50.6
Isolation (dB)
25
1.2
Weight (kg)
<5
Page 71
Summary
z
Software Structure: the host and board software are integrated in the SCC and the
ODU is a logical board.
IDU: includes IDU 610 and IDU 620.
ODU: interface, dimension, weight, power consumption, power indicator, and frequency
indicator
Hybrid coupler: interface and main indicators
Page 72
Contents
1. Equipment Overview
2. Equipment Structure
3. Equipment Protection
Page 73
Active
ODU
Active
IF Board
Cross-connection
board
Hybrid coupler
Antenna
mute
Standby
ODU
Standby
IF Board
Page 74
Service
board
Switch point
Switch condition
Characteristics
Page 75
Active
IF Board
Cross-connection
board
Antenna 1
Antenna 2
Mute
Standby
ODU
Standby
IF Board
Page 76
Service
board
Active
ODU
Active
IF Board
Cross-connection
board
Antenna Hybrid
Standby
ODU
tf2
Standby
IF Board
rf2
Page 77
Service
board
tf1
Active
ODU
Active
IF Board
Cross-connection
board
Antenna 1
Antenna 2
Standby
ODU
tf2
Standby
IF board
rf2
Page 78
Service
board
Switch point
Switch condition
Characteristics
Page 79
Reverse Switch
z
Introduction
Switch condition
When the system fails to detect the hardware faults in the transmission
direction, the HSB and SD cannot be triggered.
Remote site detecting the failure and send RDI to local site to trigger the HSB
or SD switch.
Characteristics
Page 80
Questions
z
Page 81
Summary
Contents Review
z
Main characteristics
Page 82
Thank You
www.huawei.com