THERMOCOMTM REPORT EXPRESS
2. OPERATION INSTRUCTION
2.1.
Browse data
2.2
Image analysis
2.2.
Image analysis
2.3.
Video analysis
14
2.4.
Generate report
17
3. SETTING
20
Details
CPU
Memory
Display card
Hard disc
rest space of installation disc is no less than 2G
Mouse
&
3-key mouse, PS/2 keyboard
keyboard
network
100M and above
adapter
Software configuration
Requirement
Details
.net framework 3.5 SP1 and above
Microsoft Visual C++2010 x86 Redistributable;
Environment
WindowsInstaller3_1;
Report Viewer.
Operation
Windows XP 32 bit/64 bit and above
system
Other SW
Adobe Reader
2. Operation Instruction
Message
and setting
Browse
Image
Image
Information
2
Informatio
n
USB: All data can be recognized automatically when USB is connected with camera, and
click Download to save the file in the selected folder on the left dendrogram. To download part
of data, please input the serial numbers in From and To.
NOTE: This is only valid for NV series and V series. For TH series, data can be
transferred by USB from camera to PC only.
FV: Files in THERMOCOM /GUIDE INFRARED FV can be downloaded and saved in selected
folder.
Delete folder: Select any folder on the left column and click to display delete dialog interface.
Click Confirm to delete the folder; click Cancel to close the dialog interface.
text.
Will be shown if voice is included, press the button to play the voice.
Will
Temperature display
Image information
Tool bar
Gauge setting
Method IIIChoose thermal image and drag into analysis interface, the program will auto
identify and show the information.
SpotPress
LinePress
Delta Press
RectanglePress
RoundPress
PolygonPress
10
IR BlendingPress
in and zoomed out by mouse. The blending part could be adjusted by moving temperature
interval. As show in the figure:
Customize gauge setting: Adjust the sliders in the dimmer to change the color effect on the
thermal image. Corresponding color to the temperature is shown in the dimmer. As show in
the figure:
to save the analysis object and customized palette. As show in the figure:
12
2.3.5 Emissivity
Single analysis object: choose one object on the measuring object information field, double
click left mouse button to popup emissivity dialog box. User could select the emissivity and
click confirm to save. As show in the figure:
Multi analysis objects: emissivity for all the analysis objects could be revised. Double click
Emissivity in IR parameters area, the emissivity dialog box will be displayed. Choose the
checkbox on the right to apply the customized emissivity to all the objects. As show in the
figure:
13
Display method
Camera recognize
Tool bar
Video
gauge
Video information
Video status
14
There are two connecting way for TH640, Wi-Fi and USB connection.
PS: The user need install USB driver of TH series or TH640 before connection.
Users should enter the IP address in the same LAN, otherwise the connection will be failed.
2.4.2 Replay
Press
to loan video in irv. Format and video will reply automatically. The buttons under
video are for stop, pause, last frame and next frame. Analysis can be done on live video, and
Live information of analysis objects will be displayed. As show in the figure:
15
16
Align
Edition object
Image browse
Icon
Report
Show pages
Method two, click the right mouse button on the thermal imager or visual image, then there is
17
a loading option, the user could add the image in BMP, PNG, and JPG as show in the figure
Press
Press
NOTE: The selected object could be deleted by press Delete on the keyboard.
for template database. User could modify the current template layout, press
to
19
3. Setting
5 tabs could be set,
Language: Chinese, English, German, Polish and Spanish are available.
Unit: temperature unit(Celsius degree, Fahrenheit degree and Kelvin ) and parasang (Meter
and Inch).
20
Report: Default setting custom report icon, header, footer and auto launch. If choose auto
launch, the report will be opened by system associated program.
Others: Open and close setting for information popup and auto update.
21
4. FAQ
Ezshare connection instruction
Method one, automatically access IP address
Open Wi-Fi SD card, access Menu-Control panel-Network connection, double click the icon
of wireless connection, then there is a local area connection interface, choose the SSID
named ex Share, the password is 88888888 to connect the network as the figure.
22
Open the IrAnalyser, click Data input-WIFI, and press Refresh to get the file information.
23
24
25