You are on page 1of 6

FV3

Tunnel lighting
Front access
APPLICATIONS

The FV3 tunnel lighting luminaire, with front access, offers a wide variety
of light distribution levels. It can be fitted with any type of lamp and is
available in a wide variety of lengths.

Symmetrical and asymmetrical lighting of road and motorway


tunnels and subways.

ADVANTAGES
- Integration of any type of source that can be used in tunnels
(high and low-pressure sodium, fluorescent, compact fluorescent), for all power ratings with one or two lamps positioned
end to end or parallel (see table of lamps).
- The diversity of its accessories and lengths means that the
FV3 can be used to light up all underground road or motorway
installation zones.
In all its configurations, the FV3 offers front access by a
continuous hinge/closure system.

DESCRIPTION
Tight luminaire with front access consisting of the following
components:
obody and continuous hinge/closure system: extruded aluminium protected by electrolytic oxidation (class 15);
otwo side plates: die-cast aluminium protected by hot polyester powdering;
oclear or frosted safety protector glass with or without screenprinting;
opull-out reflector made of anodised aluminium;
opull-out control gear plate;
oindependent mounting system.

CHARACTERISTICS
Tightness

IP 65

Impact resistance (glass)

IK 08

Aerodynamic resistance (CxS)


Example: length 1130 mm

Front: 0,223 m2
Side: 0,061 m2

Insulation

I ou II

According to standard EN 60598-1 and 2/3

FV3
INSTALLATION
The FV3 luminaires are mounted at four points.

are adapted to the conditions of use and to the nature of the

The materials of the suspended mounting parts (AG3 alumi-

materials in direct contact with them.

nium, 316 stainless steel or Modar) and the screws and bolts

1. Fixed suspended mounting

A
A

With 'Z'-shaped brackets

Swivelling

Swivelling and adjustable


(luminaire/wall distance)

II. Pull-out suspended mountings


A
50

;;
;;
;;
;;
;; ;;
Tilting

m
m

Horizontal ( 5)

Swivelling and adjustable


(3 directions)
A = 90 mm with 10 mm transversal adjustment

>130 80
mm mm

Partial

240 mm

Total (Please consult us)

80 mm

310 <330
mm

30 mm

II. Recessing

ELECTRICAL INSTALLATION

One or two compression glands ( 13 - 16 - 21 mm)

Tight, pull-out base (3 or 5 contacts)

MAINTENANCE

Output cable and tight, pull-out plug (3 or 5 contacts)

DIMENSIONS

After undoing the continuous closure system, the protector


m
130 m

glass tilts around a continuous hinge system.

va
ria
bl
e

The glass is easy to dismantle and replace.


The control gear is placed on a pull-out plate. Its positioning lamp, the number of lamps and the type of reflector.

193 mm

next to or behind the reflector - depends on the choice of

(s
ee

la
m
ps

ta
bl
e)

m
282 m

OPTIONS
- Narrow beam systems
frosted glass for applications with high-pressure sodium
lamps
bidirectional internal louvres
unidirectional internal louvres
- Fuses
Tool-free access to the reflector, lamp and control gear.

- Colour filters

LAMPS
Control
gear localization

High pressure sodium


83/1430/1529

168

1200

behind the
reflector

70 W

480mm
9kg

760mm
14,5kg

480mm
9kg

760mm
14,5kg

560mm
9,54kg

1130mm
18kg

100 W

560mm
9,5kg

760mm
15kg

560mm
10kg

1130mm
18,5kg

560mm
10kg

1130mm
18,5kg

150 W

560mm
10,5kg

1130mm
20kg

760mm
12kg

1550mm
24kg

560mm
10,5kg

1130mm
20kg

250 W

760mm
13,5kg

1550mm
27kg

760mm
13,5kg

1550mm
27kg

400 W

760mm
15,5kg

1550mm
31kg

760mm
15,5kg

1550mm
31kg

Low pressure sodium


83/168/1002/1424/1429/1089
35 W
E 26 W
55 W
E 36 W
90 W
E 66 W
135 W
E 91 W
180 W
E 131 W

1518

450mm
9kg

790mm
15kg

450mm
9kg

790mm
15kg

560mm
10kg

1040mm
17kg

560mm
10kg

1040mm
17kg

670mm
10,5kg

1260mm
20kg

1240mm
13,5kg

1550mm
23kg

Compact fluorescent
83/168/1297/1089/1518

1192

36 W

570mm
10kg

1240mm
20kg

570mm
10kg

570mm
12kg

1240mm
22kg

1240mm
24kg

40-55 W

670mm
11kg

1240mm
20kg

670mm
11kg

670mm
13kg

1240mm
22kg

1240mm
24kg

Fluorescent ( 26 mm)
83/168/1424/1099/1297

1192

36 W

1320mm
18,5kg

1320mm
20,5kg

1320mm
20,5kg

58 W

1620mm
21kg

1620mm
23kg

1620mm
23kg

end of the
reflector
type of
reflector

FV3
PHOTOMETRY
Ceiling - central

Ceiling - side

Ceiling - central

Ceiling - central

Ceiling - side

Reflector 168

Reflector 1529

Reflector 1518

2 x 58 W fluorescent

1 x 400 W high-pressure sodium

1 x 36 W low-pressure sodium

420 350 280 210 140 70

420 350 280 210 140 70

90/270

0/180

270/90

420 350 280 210 140 70

0/180

270/90

Ceiling - central

Ceiling - central

Ceiling - side

Reflector 83

Reflector 1200

Reflector 83

1 x 180 W low-pressure sodium

1 x 150 W high-pressure sodium

1 x 400 W high-pressure sodium

270 225 180 135 90

420 350 280 210 140 70

45

270/90

0/180

270/90

0/180

480 400 320 240 160 80

15/165

270/90

0/180

FV3

Corner

Side walls

Corner

Side walls

Reflector 1430

Reflector 1424

1 x 400 W high-pressure sodium

1 x 180 W low-pressure sodium

660 550 440 330 220 110

420 350 280 210 140 70

280/90

0/180

270/90

Corner

Corner

Corner

Reflector 1002

Reflector 1089

Reflector 1257

1 x 180 W low-pressure sodium

2 x 58 fluorescent

2 x 58 W fluorescent

420 350 280 210 140 70

480 400 320 240 160 80

270/90

0/180

270/90

270 225 180 135 90

45

270/90

0/180

You might also like