You are on page 1of 5

2/7/2006

WIND05 v1-0
Detailed Wind Load Design (Method 2) per ASCE 7-05
Analysis by: ??
Description: ??
User Input Data
Structure Type
Building
Basic Wind Speed (V)
130
Struc Category (I, II, III, or IV
II
Exposure (B, C, or D)
C
Struc Nat Frequency (n1)
1
Slope of Roof
5.0
Slope of Roof (Theta)
22.6
Type of Roof
Monoslope
Kd (Directonality Factor)
0.85
Eave Height (Eht)
30.00
Ridge Height (RHt)
50.00
Mean Roof Height (Ht)
40.00
Width Perp. To Wind Dir (B) 45.00
Width Paral. To Wind Dir (L 35.00

Company Name:

??
Calculated Parameters
Importance Factor
1

mph

Hurricane Prone Region (V>100 mph)

Hz
:12
Deg

ft
ft
ft
ft
ft

Calculated Parameters
Type of Structure
Height/Least Horizontal Dim
Flexible Structure

Table 6-2 Values


9.500
900.000

Alpha =
zg =

At =
Bt =
Bm =
Cc =
l=
Epsilon =
Zmin =

1.14
No

0.105
1.000
0.650
0.200
500.00 ft
0.200
15.00 ft

Gust Factor Category I: Rigid Structures - Simplified Method


Gust1 For rigid structures (Nat Freq > 1 Hz) use 0.85
Gust Factor Category II: Rigid Structures - Complete Analysis
Zm
0.6 * Ht
Izm
Cc * (33/z)^0.167
Lzm
l*(zm/33)^Epsilon
Q
(1/(1+0.63*((Min(B,L)+Ht)/Lzm)^0.63))^0.5
Gust2 0.925*((1+1.7*Izm*3.4*Q)/(1+1.7*3.4*Izm))
Gust Factor Summary
G
Since this is not a flexible structure the lessor of Gust1 or Gust2 are used

0.85
24.00 ft
0.2109
469.15 ft
0.9135
0.8810
0.85

Fig 6-5 Internal Pressure Coefficients for Buildings, Gcpi

Condition

Gcpi
Max +
0.00
0.55
0.18
0.18

Open Buildings
Partially Enclosed Buildings
Enclosed Buildings
Enclosed Buildings

Developed by Meca Enterprises, Inc. Copyright 2006

??

Max 0.00
-0.55
-0.18
-0.18

Page No. 1 of 4

2/7/2006

WIND05 v1-0
Detailed Wind Load Design (Method 2) per ASCE 7-05
6.5.12.2.1 Design Wind Pressure - Buildings of All Heights
Elev

Kz

Kzt

qz

0
50
40
30
20
15

1.09
1.04
0.98
0.90
0.85

1.00
1.00
1.00
1.00
1.00

lb/ft^2
40.22
38.38
36.12
33.17
31.22

Pressure (lb/ft^2)
Windward Wall*
+GCpi
-GCpi
20.44
34.26
19.19
33.00
17.65
31.47
15.65
29.46
14.32
28.14

Figure 6.5.12.2.4 Parapets


Type of Parapet
Top Elevation of Parapet
Parapet-Windward Pressure
Parapet-Leeward Pressure

Enclosed
18.00
48.66
-32.44

ft
lb/ft ^2
lb/ft ^2

Figure 6-6 - External Pressure Coefficients, Cp


Loads on Main Wind-Force Resisting Systems (Method 2)

Theta
B
h
z
L

Variable Formula

Kh
Kht
Qh
Khcc
Qhcc

2.01*(Ht/zg)^(2/Alpha)
Topographic factor (Fig 6-4)
.00256*(V)^2*I*Kh*Kht*Kd
Comp & Clad: Table 6-3 Case 1
.00256*V^2*I*Khcc*Kht*Kd

Value

Units

1.04
1.00
38.38
1.04
38.38

psf

Wall Pressure Coefficients, Cp


Surface
Windward Wall (See Figure 6.5.12.2.1 for Pressures)

psf

Cp
0.8

Roof Pressure Coefficients, Cp


Roof Area (sq. ft.)
Reduction Factor

Developed by Meca Enterprises, Inc. Copyright 2006

1.00

??

Page No. 2 of 4

2/7/2006

WIND05 v1-0
Detailed Wind Load Design (Method 2) per ASCE 7-05
Pressure (psf)
+GCpi
-GCpi
Leeward Walls (Wind Dir Normal to 45 ft wall)
-0.50
-23.22
-9.40
Leeward Walls (Wind Dir Normal to 35 ft wall)
-0.44
-21.35
-7.54
Side Walls
-0.70
-29.74
-15.93
Roof - Wind Normal to Ridge (Theta>=10) - for Wind Normal to 45 ft face
Windward - Min Cp
-0.60
-26.35
-12.53
Windward - Max Cp
-0.09
-9.73
4.09
Leeward Normal to Ridge
-0.60
-26.48
-12.66
Overhang Top (Windward)
-0.60
-19.44
-19.44
Overhang Top (Leeward)
-0.60
-19.57
-19.57
Overhang Bottom (Applicable on Windward only)
0.80
24.56
24.56
Roof - Wind Parallel to Ridge (All Theta) - for Wind Normal to 35 ft face
Dist from Windward Edge: 0 ft to 80 ft - Max Cp
-0.18
-12.78
1.04
Dist from Windward Edge: 0 ft to 20 ft - Min Cp
-1.21
-46.41
-32.60
Dist from Windward Edge: 20 ft to 35 ft - Min Cp
-0.74
-31.19
-17.38
Dist from Windward Edge: 40 ft to 45 ft - Min Cp
-0.66
-28.29
-14.48
* Horizontal distance from windward edge

Calculations for Wind Normal to 45 ft Face

Cp

Additional Runs may be req'd for other wind directions

Figure 6-14 - External Pressure Coefficients, GCp


Loads on Components and Cladding for Buildings w/ Ht <= 60 ft
for Monoslope Roofs

2a
4a

a
2

Theta
Ht

2
a

a=

3.5
==>
3.50
ft
Double Click on any data entry line to receive a help Screen
GCp
Wind Press (lb/ft^2)
Component
Width
Span
Area
Zone
(ft)
(ft)
(ft^2)
Max
Min
Max
Min
CMU Walls
15
5
75.00
5
0.85
-1.09
39.35
-48.77
Roof Joists
5
35
408.33
1
0.30
-1.10
18.42
-49.12
Roof Panel
2
5
10.00
3
0.40
-2.90
22.26
-118.20
Roof Panel
2
6
12.00
2
0.39
-1.57
21.95
-67.10
0.00
0.00
Note: * Enter Zone 1, 2, 2', 3, 3' (See sketch), 4 & 5 (Wall Zones calculated per Fig 6-5A)
* Use 1H, 2H, and 3H for Roof Overhangs (Per Fig 6-5B)

Developed by Meca Enterprises, Inc. Copyright 2006

??

Page No. 3 of 4

WIND05 v1-0
Simplified Wind Load Design (Method 1) per ASCE 7-05
Description: ??
Analysis by: ??

Load
Case
1
2

V
Cat
Exp

Basic Wind Speed


Structural Category (I, II, III, and IV)
Exposure Category (B, C, or D)

130 mph
II
C

RHt
Eht
Ht
Theta
L
B
Kzt

Ridge Height
Eave Height
Mean Roof Height of Building
Roof Angle
Length of Building (If Gabled roof, along Ridge)
Width of Building (Perpendicular to Ridge)
Topographic Factor

Lambda
I
a
2a

Adjustment Factor for Building Height and Exposure


Importance Factor
10% of Least Horiz Dim or 0.4h, whichever is less
Length over which Zone A acts on Each Corner

50
30
40.00
41.63
35
45
1

ft
ft
ft
Deg
ft
ft

1.49
1.00
3.50 ft
7.00 ft

Wind Pressure ps (psf) on Main Wind Force Resisting System (MWFRS)


Zones
Horizontal Pressures
Vertical Pressures
Overhangs
A
B
C
D
E
F
G
H
EOH
GOH
44.85
30.69
35.76
24.59
3.43 -27.27
1.19
-23.39
-15.79 -18.03
44.85
30.69
35.76
24.59
17.28 -13.41
14.90
-9.54
-15.79 -18.03

Notes:
* ps = Lambda * I * ps30

Developed by Meca Enterprises, Inc. Copyright 2006

??

Page 1 of 2

WIND05 v1-0
Simplified Wind Load Design (Method 1) per ASCE 7-05
Description: ??
Analysis by: ??

Double Click on any data entry line to receive a help Screen


Wind Pressure ps (psf) on Components and Cladding (C&C)
Pressure (psf)
Description
Width
Span
Area
Zone
(ft)
(ft)
(ft^2)
Positive Negative
CMU Walls
15
5 75.00
5
39.56
-49.10
Roof Joists
5
35 408.33
4
34.92
-38.64
Roof Joists
5
35 408.33
3
37.55
-45.30
Roof Panel
2
5 10.00
2
41.42
-53.04
Roof Panel
2
6 12.00
1
41.18
-44.85

Notes:
Zones 2H and 3H represent roof overhangs
Zones 1, 2, and 3 represent the roof
Zones 4 and 5 represent the walls
Developed by Meca Enterprises, Inc. Copyright 2006

??

Page 2 of 2

You might also like