You are on page 1of 84

SURFACE ELECTRIC WATER PUMPS

FOR DOMESTIC AND INDUSTRIAL USE

City Pumps s.r.l.


Via Enrico Fermi, 27 - P.O. BOX 84
37047 San Bonifacio (Verona) Italy
Tel. (+39) 045 6102379
Fax (+39) 045 7614264
e-mail: sales@citypumps.com
www.citypumps.com

Introduction

Co m pa ny p rof i le
CITY PUMPS is the latest breakthrough from INOX
POMPE. The company has undergone a restyling with a
European brand image and an international repute in
the manufacture of electric water pumps for civilian,
agricultural and industrial applications.
The productive standards implement all the electric
and hydraulic inspections prescribed by the EU safety
regulations and use productive plants that are among
the technologically most advanced in the electro technical and mechanical industry.
We export to over 50 countries.
CITY PUMPS works in conjunction with leading international groups in the research and production of civilian
and industrial electric water pumps.

a wide range of...

Performances of City Pumps surface range of water pumps.


H (m)
120

100
INDUSTRIAL

City Pumps offers a wide range of electric water pumps for


domestic, civilian and industrial applications.

80

Its range of products meets the requirements of an efficient product, simple to use, flexible and with low power
consumption.

60

40

CIVILIAN / DOMESTIC

20

10

100

1000

10000
Q (l/min)

...electric water pumps...

ICH

(medium flow rates)

ICn

IC-SS

IC

IQ

IP

Products

Range of performance

Applications

Page

Flow rate up to 50 l/min


(3.0 m3/h)
Head up to 90 m

They are recommended for pumping clean water without abrasive particles
and liquids that are chemically non aggressive to the materials from which
the pump is made. For their reliability, simplicity of use and economy they
are suitable for domestic use and in particular for distributing water in
combination with small pressure sets, for irrigating gardens.
The pumps must be installed in enclosed places, or at least protected against
inclement weather.

Page 10

Flow rate up to 50 l/min


(3.0 m3/h)
Head up to 90 m

They are recommended for pumping clean water without abrasive particles
and liquids that are chemically non aggressive to the materials from which
the pump is made.
The hydraulic characteristics of these pumps, together with their compactness,
make them suitable for use in the industrial sector. The pumps must be installed
in enclosed places, or at least protected against inclement weather.

Page 12

Flow rate up to 160 l/min


(9.6 m3/h)
Head up to 58 m

They are recommended for pumping clean water and liquids that are chemically
non aggressive to the materials from which the pump is made.
Reliable and maintenance free they are widely used in the domestic and
civil sector, in particular for water distribution in combination with small
or medium pressure sets, for transfer in general, for irrigating gardens. The
pumps must be installed in enclosed places, or at least protected against
inclement weather.

Page 14

Maximum flow rate 160 l/min


(9.6 m3/h)
Maximum head 23 m

It is recommended for pumping clean water and liquids that are chemically
non aggressive to the materials from which the pump is made. The construction of these centrifugal pumps makes them suitable for use in the domestic,
agricultural and industrial sector. All the wetted parts are in stainless steel
AISI304 to guarantee total hygiene and maximum resistance to corrosion.
The pump must be installed in enclosed places, or at least protected against
inclement weather.

Page 16

Flow rate up to 250 l/min


(15 m3/h)
Head up to 57 m

They are recommended for pumping clean water and liquids that are chemically
non aggressive to the materials from which the pump is made.
The pumps in this series are made to standards EN 733 - DIN 24255 and are
specifically used in the civil, industrial or agricultural sectors where their
characteristics of sturdiness and reliability can be best appreciated.
The pumps must be installed in enclosed places, or at least protected against
inclement weather.

Page 18

Flow rate up to 600 l/min


(36 m3/h)
Head up to 39 m

The ICH series is recommended for civil, agricultural and industrial applications. The high flow rates and continuous rating make it ideal for irrigation
with flowing and sprinkling water, for drawing water from lakes, rivers,
wells, or for industrial applications that need to achieve large flow rates at
medium-low heads.
The pumps must be installed in enclosed places, or at least protected against
inclement weather.

Page 20

...for any requirement

MS 07-08

MSG

ICB

PRO-NCO

NCO

ICH

(high flow rates)

Products

Range of performance

Applications

Page

Flow rate up to 1800 l/min


(108 m3/h)
Head up to 24.5 m

The ICH series is recommended for use in the civil, agricultural and industrial
field. The high flow rates and continuous rating make it ideal for irrigation
with flowing and sprinkling water, for drawing water from lakes, rivers,
wells, or for industrial applications that need to achieve large flow rates at
medium-low heads.
The pumps must be installed in enclosed places, or at least protected against
inclement weather.

Page 22

Flow rate up to 350 l/min


(21 m3/h)
Head up to 20 m

They are recommended for pumping water and liquids that are chemically
non aggressive to the materials from which the pump is made. The open
impeller design allows the pumping of liquids with relatively high levels of
impurities without risk of clogging the impeller. For this reason the NCO series are suitable for use in industry, for the transfer of water from canals, rivers, reservoirs, tanks, etc. The pumps must be installed in enclosed places,
or at least protected against inclement weather.

Page 24

Flow rate up to 350 l/min


(21 m3/h)
Head up to 20 m

They are recommended for pumping water and liquids that are chemically non
aggressive to the materials from which the pump is made. The open impeller
design allows the pumping of liquids with relatively high levels of impurities
without risk of clogging the impeller. For this reason the PRO-NCO series are
suitable for use in systems for washing fruit, vegetables, fish, shellfish, meat,
in industrial systems for washing metal parts, glass containers, and for the
circulation of cooling liquids.
The pumps must be installed in enclosed places, or at least protected against
inclement weather.

Page 26

Flow rate up to 400 l/min


(24 m3/h)
Head up to 112 m

They are recommended for pumping clean water and liquids that are chemically
non aggressive to the materials from which the pump is made.
Their high efficiency and adaptability to the most varied, even unusual applications, make them the ideal choice in the domestic, civil and industrial
field; in particular for distributing water in combination with pressure sets,
for increasing pressure in the mains, for fire-fighting sets.
The pumps must be installed in enclosed places, or at least protected against
inclement weather.

Page 28

They are recommended for pumping clean water and liquids that are chemically
non aggressive to the materials from which the pump is made.
Due to their reliability, quiet running and low maintenance, they are suitable
for domestic applications including water supplies (as a pressure set), garden
irrigation, etc. The pumps must be installed in enclosed places, or at least
protected against inclement weather

Page 36

They are recommended for pumping clean water and liquids that are chemically
non aggressive to the materials from which the pump is made.
Due to their reliability and quiet running, they are suitable for domestic applications including water supplies (as a pressure set), garden irrigation, etc.
The pumps must be installed in enclosed places, or at least protected against
inclement weather.

Page 38

Flow rate up to 130 l/min


(7.8 m3/h)
Head up to 47 m

Flow rate up to 120 l/min


(7.2 m3/h)
Head up to 50 m

a complete line of
electric water pumps...

JS

(up to 0.85 HP)

VMSE B

VMSE A

VMS B

VMS A

Products

Range of performance

Applications

Page

Flow rate up to 80 l/min


(4.8 m3/h)
Head up to 105 m

They are recommended for pumping clean water and liquids that are chemically non aggressive to to the materials from which the pump is made.
Their reliability and quiet running make them suitable for domestic and
civil applications, because the pump is fully submersible with the motor
cooled by the pumped liquid, it can be used safely in wet environments and
in spaces with insufficient ventilation.

Page 40

Flow rate up to 120 l/min


(7.2 m3/h)
Head up to 105 m

They are recommended for pumping clean water and liquids that are chemically non aggressive to the materials from which the pump is made.
Their reliability and quiet running make them suitable for domestic and civil
applications, because the pump is fully submersible with the motor cooled by
the pumped liquid, it can be used safely in wet environments and in spaces
with insufficient ventilation.

Page 42

Maximum flow rate 80 l/min


(4.8 m3/h)
Head up to 105 m

They are recommended for pumping clean water and liquids that are
chemically non aggressive to the materials from which the pump is made.
Their reliability and quiet running make them suitable for domestic and civil
applications and, because the pump is fully submersible with the motor cooled
by the pumped liquid, it can be used safely in wet areas and in spaces with
insufficient ventilation. The enclosed design also eliminates the possibility
of water escaping as a result of seal failure, making it suitable for use in
carpeted or other delicate environments

Page 44

Maximum flow rate 120 l/min


(7.2 m3/h)
Head up to 105 m

They are recommended for pumping clean water and liquids that are
chemically non aggressive to the materials from which the pump is made.
Their reliability and quiet running make them suitable for domestic and civil
applications and, because the pump is fully submersible with the motor cooled
by the pumped liquid, it can be used safely in wet areas and in spaces with
insufficient ventilation. The enclosed design also eliminates the possibility
of water escaping as a result of seal failure, making it suitable for use in
carpeted or other delicate environments.

Page 46

Flow rate up to 50 l/min


(3 m3/h)
Head up to 47 m

They are recommended for pumping clean water and liquids that are chemically non aggressive to the materials from which the pump is made.
JS self-priming pumps are designed for suction lifts and can be positioned
above the water source, including applications with air entrained in the
water. Due to their reliability and low maintenance, they are recommended
for domestic use, including water distribution (as part of a pressure set),
garden irrigation, etc.
The pumps must be installed in enclosed places, or at least protected against
inclement weather.

Page 48

Page

Flow rate up to 80 l/min


(4.8 m3/h)
Head up to 70 m

They are recommended for pumping clean water and liquids that are chemically non aggressive to the materials from which the pump is made.
JS self-priming pumps are designed for suction lifts and can be positioned
above the water source, including applications with air entrained in the water.
Due to their reliability and low maintenance, they are recommended for
domestic use, including water distribution (as part of a pressure set), garden
irrigation, etc. The pumps must be installed in enclosed places, or at least
protected against inclement weather.

Page 50

Flow rate up to 160 l/min


(9.6 m3/h)
Head up to 96 m

They are recommended for pumping clean water and liquids that are chemically non aggressive to the materials from which the pump is made.
JSE self-priming pumps are designed for suction lifts and can be positioned
above the water source, including applications with air entrained in the water.
Due to their reliability and low maintenance, they are recommended for
domestic use, including water distribution (as part of a pressure set), garden
irrigation, etc. The pumps must be installed in enclosed places, or at least
protected against inclement weather.

Page 52

Flow rate up to 80 l/min


(4.8 m3/h)
Head up to 72 m

They are recommended for pumping clean water and liquids that are chemically non aggressive to the materials from which the pump is made.
JET-SS self-priming pumps are designed for suction lifts and can be positioned
above the water source, including applications with air entrained in the water.
Due to their reliability and low maintenance, they are recommended for
domestic use, including water distribution (as part of a pressure set), garden
irrigation, etc. The pumps must be installed in enclosed places, or at least
protected against inclement weather.

Page 54

Flow rate up to 6000 l/min


(360 m3/h)
Head up to 95 m

They are recommended for pumping clean water and liquids that are chemically
non aggressive to the materials from which the pump is made.
This series is suitable for supplying and moving water, in cooling, heating,
circulating and conditioning systems, for fire fighting, irrigation, industrial
and agricultural applications. Manifacture in accordance with dimensional
standards EN 733 - DIN 24255 ensures models are fully interchangeable.The
design allows the pump body to be removed without disconnecting it from
the pipes (back pull out). The pumps must be installed in enclosed places, or
at least protected against inclement weather.

Page 56

UTILITY

Flow rate up to 50 l/min


(3 m3/h)
Head up to 47 m

Portable self-priming pumps capable of clearing entrained air from the


suction pipe.
Recommended for gardening, vegetable gardens, washing and hobby
applications they are suitable for use with any liquids compatible with the
materials of construction.

Page 74

PC PUMP

Products

Domestic pumps with a pressure sensing electronic controller for automatic


operation; the pump operates as required as a tap is opened or closed.
The controller also provides protection for the pump against dry running.

Page 77

Small pressure sets with vessel, for automatic operation. Suitable for the
supply of pressurised water in the home or in holiday homes.

Page 78

JET-SS

JSE

(from 1.5 to 3 HP)

JS

(from 1 to 1.5 HP)

Applications

BOOSTER SETS

...to satisfy
any requirements
Range of performance

10

IP
pumps with peripheral impeller

IP900

IP1000
IP800

H (m)

IP700

IP500

Q
Q = Flow rate H = Total manometric head

TYPE
Single-phase

IP 500M
IP 700M
IP 800M
IP 1000M
IP 900M

Tolerance of the performance curves according to EN ISO 9906 App. A.

POWER
Three-phase

IP 500
IP 700
IP 800
IP 1000
IP 900

m3/h
l/min

kW

HP

0.37
0.50
0.60
0.75
0.75

0.50
0.70
0.85 H metres
1
1

0
0
40
55
65
70
90

0.3
5
38
50
62
66
82

0.6
10
33.5
45.5
57
61
71

0.9
15
29
40.5
52
56
60

1.2
20
24
36
47
51
49

1.5
25
19.5
31
42
46
38

1.8
30
15
27
37
41
27

2.1
35
10
22
32
36.5
17

2.4
40
5
17
27
31
5

3.0
50

3.6
60

4.2
70

4.8
80

5.4
90

8
18
22

DIMENSIONS AND WEIGHTS


TYPE
Single-phase

PORTS
Three-phase

DN1

DIMENSIONS mm

DN2

IP 500M

IP 500

42

243

IP 700M

IP 700

48

258/250

IP 800M

IP 800

IP 1000M

IP 1000

IP 900M

IP 900

3/4

3/4

55

285

58

288

h1

152

63

179

71

h2

h3

75

138

80

143

85

156

95

166

kg
m

n1

80

120

100

55

20

7
90

138

112

62

1~

3~

5.3

5.3

7.7

6.4

10.1

9.2

10.3

9.9
9.3

11

RANGE OF PERFORMANCE
Flow rate up to 50 l/min (3.0 m3/h)
Head up to 90 m
LIMITS OF USE
Manometric suction lift up to 8 m
Liquid temperature up to + 60C
Environment temperature up to + 40C

INSTALLATION AND USE


They are recommended for pumping clean water
without abrasive particles and liquids that are
chemically non aggressive to the materials from
which the pump is made.
FOR THEIR RELIABILITY, sImplicitY OF USE AND
economY THEY ARE SUITABLE FOR DOMESTIC
USE AND in particUlar FOR distribuTING
WATER in COMBINATION WITH SMALL PRESSURE SETS, FOR irrigaTING GARDENS.
The pumps must be installed in enclosed places, or
at least protected against inclement weather.
GUARANTEE 2 YEARS subject to our general
terms of sale.
CONSTRUCTION CHARACTERISTICS
PUMP BODY: cast iron, with threaded ports
ISO228/1.
MOTOR BRACKET: aluminium with brass insert;
reduces starting difficulties due to seizure of the
impeller after long periods of inactivity.

IMPELLER: brass, of the type with radial peripheral vanes.


MOTOR SHAFT:
stainless steel EN 10088-3 - 1.4104.
MECHANICAL SEAL:
ceramic - graphite - NBR.
ELECTRIC MOTOR: the pumps are close-coupled
to a carefully matched electric motor, quiet running, totally enclosed fan cooled, suitable for
continuous duty.
IP M: single-phase 230 V - 50 Hz with capacitor and
thermal overload protector.
IP: three-phase 230/400 V - 50 Hz.
INSULATION: class F.
PROTECTION: IP 44.
OPTIONS ON REQUEST
special mechanical seal
other voltages or frequency 60 Hz

CONSTRUCTION AND SAFETY STANDARDS


EN 60 335-1
EN 60034-1
IEC 335-1
IEC 34-1
CEI 61-150
CEI 2-3

DIMENSIONS
f

h1

DN1

h3

h2

DN2

n1
n

12

IQ
pumps with peripheral impeller

IQ1000H

IQ1000
IQ800

H (m)

IQ700

IQ500

Q = Flow rate H = Total manometric head

TYPE
Single-phase

IQ 500M
IQ 700M
IQ 800M
IQ 1000M
IQ 1000HM

Three-phase

IQ 500
IQ 700
IQ 800
IQ 1000
IQ 1000H

Tolerance of the performance curves according to EN ISO 9906 App. A.

POWER
kW
HP

0.37
0.50
0.60
0.75
0.75

m3/h
l/min

0.50
0.70
0.85 H metres
1
1

0
0
40
55
65
70
90

0.3
5
38
50
62
66
82

0.6
10
33.5
45.5
57
61
71

0.9
15
29
40.5
52
56
60

1.2
20
24
36
47
51
49

1.5
25
19.5
31
42
46
38

1.8
30
15
27
37
41
27

2.1
35
10
22
32
36.5
17

2.4
40
5
17
27
31
5

3.0
50

3.6
60

4.2
70

4.8
80

5.4
90

8
18
22

DIMENSIONS AND WEIGHTS


TYPE
Single-phase
IQ 500M
IQ 700M
IQ 800M
IQ 1000M
IQ 1000HM

Three-phase
IQ 500
IQ 700
IQ 800
IQ 1000
IQ 1000H

PORTS
DN1
DN2
1
3/4

1
3/4

a
22
22

f
223
234/227

h
152

h1
108
113

253

179

121

253

179

126

h2
30
27

DIMENSIONS mm
h3
i
138
78
143

kg
m

n1

80

120

100

w
55
57

151

83

90

138

112

62

153

84

90

138

112

62

1~
5.3
7.1
9.9
10.0
10.0

3~
5.3
6.3
8.9
8.8
9.0

13

RANGE OF PERFORMANCE
Flow rate up to 50 l/min (3.0 m3/h)
Head up to 90 m
LIMITS OF USE
Manometric suction lift up to 8 m
Liquid temperature up to + 90C
Environment temperature up to + 40C

INSTALLATION AND USE


They are recommended for pumping clean water
without abrasive particles and liquids that are
chemically non aggressive to the materials from
which the pump is made.
THE HYDRAULIC CHARACTERISTICS OF THESE
PUMPS, TOGETHER WITH THEIR COMPACTNESS, MAKE THEM SUITABLE FOR USE IN THE
industrial SECTOR. The pumps must be installed
in enclosed places, or at least protected against inclement weather.

special mechanical seal


protection IP 55
other voltages or frequency 60 Hz

impeller after long periods of inactivity.


IMPELLER: brass, of the type with radial peripheral vanes.
MOTOR SHAFT:
stainless steelEN 10088-3 - 1.4104.
MECHANICAL SEAL:
ceramic - graphite - NBR.
ELECTRIC MOTOR: the pumps are close-coupled
to a carefully matched electric motor, quiet running, totally enclosed fan cooled, suitable for
continuous duty.
IQ M: single-phase 230 V - 50 Hz with capacitor and
thermal overload protector.
IQ: three-phase 230/400 V - 50 Hz.
INSULATION: class F.
PROTECTION: IP 44.

GUARANTEE 2 YEARS subject to our general


terms of sale.
CONSTRUCTION CHARACTERISTICS
PUMP BODY: cast iron, with threaded ports
ISO228/1.
MOTOR BRACKET: aluminium with brass insert;
reduces starting difficulties due to seizure of the

CONSTRUCTION AND SAFETY STANDARDS


EN 60034-1
IEC 34-1
CEI 2-3

OPTIONS ON REQUEST
pump shaft in stainless steel
EN 10088-3 - 1.4401 (AISI 316)

DIMENSIONS
f

h3
a

h1
DN1

h2

DN2

n1
n

14

IC
centrifugal pumps

IC300

IC200
IC 150
IC100H
IC 75
H (m)

IC150L

IC100
IC50

Q
Q = Flow rate H = Total manometric head

Single-phase

IC 50M
IC 75M
IC 100M
IC 100MH
IC 150M
IC 150LM
IC 200M

TYPE

Three-phase

IC 50
IC 75
IC 100
IC 100H
IC 150
IC 150L
IC 200
IC 300

Tolerance of the performance curves according to EN ISO 9906 App. A.

0.37
0.55
0.75
0.75
1.1
1.1
1.5
2.2

m3/h
l/min

0
0
0.50
23
0.75
33
1
29.5
1
36
H metres
1.5
41
1.5
36
2
50
3
58

POWER
kW
HP

0.6
10
22
32

34

1.2
20
21
31
29
33.5

1.8
30
20
29.5
28.5
33
38
35
46
55

2.4
40
19
28.5
28
32.5
37
34.5
44.5
54.5

3.0
50
18
27
27.5
31.5
36
33.5
43
53.5

3.6
60
17
25
26.5
30
35
33
41.5
52

4.2
70
15.5
23
26
28.5
33.5
32
40
51

4.8
80
14
19
24.5
27
32
31
38
49.5

5.4
90

6.0
100

6.6
110

7.2
120

23
25
30
30
36
48

21

18

15

27.5
29
34.5
46

25
28
32.5
44.5

22
26.5
30.5
42.5

7.8
130

8.4
140

9.0
150

9.6
160

25
28
40.5

23
26
38.5

21

19

36

DIMENSIONS AND WEIGHTS


TYPE
Single-phase
IC 50M
IC 75M
IC 100M
IC 100MH
IC 150M-150LM
IC 200M

Three-phase
IC 50
IC 75
IC 100
IC 100H
IC 150-150LL
IC 200
IC 300

PORTS
DN1
DN2
1

a
42

DIMENSIONS mm
h2
n
123
165

f
259

h
205

h1
82

285

240

92

148

367

260

110

364

290

115

kg
n1
135

w
41

190

160

38

150

206

165

44.5

175

242

206

32.5

s
10

1
11/4

51

11

1~
7.8
11.5
12.5
12.1
19.2
25.0
-

3~
7.6
11.5
11.3
11.6
18.5
24.2
25.5

15

RANGE OF PERFORMANCE
Flow rate up to 160 l/min (9.6 m3/h)
Head up to 58 m
LIMITS OF USE
Manometric suction lift up to 7 m
Liquid temperature up to + 90C
Liquid temperature up to + 40C in the ICX
version (with technopolymer impeller)
Environment temperature up to + 40C

INSTALLATION AND USE


They are recommended for pumping clean water
and liquids that are chemically non aggressive to
the materials from which the pump is made.
RELIABLE AND MAINTENANCE FREE THEY ARE
WIDELY USED IN THE DOMESTIC AND CIVIL SECTOR, IN PARTICULAR FOR WATER DISTRIBUTION
IN COMBINATION WITH SMALL OR MEDIUM
PRESSURE SETS, FOR TRANSFER IN GENERAL,
FOR IRRIGATING GARDENS. The pumps must be
installed in enclosed places, or at least protected
against inclement weather.
GUARANTEE 2 YEARS subject to our general
terms of sale.
CONSTRUCTION CHARACTERISTICS
PUMP BODY: cast iron, with threaded ports
ISO228/1.

BODY BACK-PLATE:
stainless steel AISI 304 or cast iron on higher
powered models.
BRASS IMPELLER:
IC 75 - IC 100 - IC 150 - IC 200 - IC 300
STAINLESS STEEL IMPELLER: IC 50 - IC 100H
MOTOR SHAFT:
stainless steelEN 10088-3 - 1.4104.
MECHANICAL SEAL:
ceramic - graphite - NBR.
ELECTRIC MOTOR: the pumps are close-coupled
to a carefully matched electric motor, quiet running, totally enclosed fan cooled, suitable for
continuous duty.
IC M: single-phase 230 V - 50 Hz with capacitor and
thermal overload protector.
IC: three-phase 230/400 V - 50 Hz.
INSULATION: class F.
PROTECTION: IP 44.

OPTIONS ON REQUEST
impeller in technopolymer (IC M...X - IC...X)
special mechanical seal
other voltages or frequency 60 Hz

CONSTRUCTION AND SAFETY STANDARDS


EN 60034-1
IEC 34-1
CEI 2-3

DIMENSIONS
f

h1

DN1

h2

DN2

n1

16

IC-SS
stainless steel centrifugal pump
0

30

10

15

20

10

25

15

30

20

35

25

40
30

45
35

40
feet
90

25

80

70

IC100SS

20

51

60

H (m)

54

H=56%

15

50

40
53

10

30

20

5
10

25

0
0

50
2

75

100
5

125

150
8

l/min

175

10

m3/h

11

Q = Flow rate H = Total manometric head

TYPE
Single-phase

IC 100 MSS

Tolerance of the performance curves according to EN ISO 9906 App. A.

1.2

2.4

3.6

4.8

6.0

7.2

8.4

9.6

HP

m3/h
l/min

kW

20

40

60

80

100

120

140

160

0.75

H metres

23

21

20.5

20

18.5

17

15

13

10

POWER
Three-phase

IC 100 SS

DIMENSIONS AND WEIGHTS


TYPE
Single-phase
IC 100 MSS

PORTS
Three-phase

IC 100 SS

DIMENSIONS mm

kg

DN1

DN2

h1

h2

h3

n1

1~

3~

11/4

31.5

295

206

97

103

200

182

115

93

10

9.1

9.1

17

RANGE OF PERFORMANCE
Maximum flow rate 160 l/min (9.6 m3/h)
Maximum head 23 m
LIMITS OF USE
Manometric suction lift up to 7 m
Liquid temperature up to + 90C
Environment temperature up to + 55C

INSTALLATION AND USE


It is recommended for pumping clean water and
liquids that are chemically non aggressive to the
materials from which the pump is made. THE
CONSTRUCTION OF these centrifugal pumps
MAKES THEM SUITABLE FOR use in the domestic, agricultural and industrial sector.
all the WETTED PARTS are in stainless steel
aisi 304 to guarantee total hygiene and
maximum resistance to corrosion.
The pump must be installed in enclosed places, or at
least protected against inclement weather.

CONSTRUCTION CHARACTERISTICS
PUMP BODY: stainless steel AISI 304, with
threaded ports ISO228/1.
BODY BACK-PLATE AND DIFFUSER: AISI 304.
IMPELLER: stainless steel AISI 304, of the type
with centrifugal radial flow.
MOTOR SHAFT:
stainless steelEN 10088-3 - 1.4104.
MECHANICAL SEAL:
ceramic - graphite - NBR.
ELECTRIC MOTOR: the pumps are close-coupled
to a carefully matched electric motor, quiet
running, totally enclosed fan cooled, suitable for
continuous duty.
IC 100 MSS: single-phase 230 V - 50 Hz with
capacitor and thermal overload protector.
IC 100 SS: three-phase 230/400 V - 50 Hz.
INSULATION: class F.
PROTECTION: IP 44.

GUARANTEE 2 YEARS subject to our general


terms of sale.

OPTIONS ON REQUEST
version in stainless steelEN 10088-3 - 1.4401
(AISI 316)
special mechanical seal
other voltages or frequency 60 Hz

CONSTRUCTION AND SAFETY STANDARDS


EN 60034-1
IEC 34-1
CEI 2-3

DIMENSIONS
f

h3
h1

DN1

h2

DN2

n1

18

ICn
standardised centrifugal pumps to EN 733 - DIN 24255

ICn 400A/200

ICn 300B/200
H
H (m)

ICn 300AR/160
ICn 200A/160
H

ICn 150B/160

Q
Q = Flow rate H = Total manometric head

TYPE
Single-phase

ICn 150BM/160
ICn 200AM/160

ICn 300BM/200

Tolerance of the performance curves according to EN ISO 9906 App. A.

POWER
Three-phase

ICn 150B/160
ICn 200A/160
ICn 300AR/160
ICn 300B/200
ICn 400A/200

kW

HP

1.1
1.5
2.2
2.2
3

1.5
2
3
3
4

m3/h
l/min

H metres

0
0
33
38
42
49
57

3.0
50
32.5
37
41
48
56

3.6
60
32
36.8
41
47.5
55.8

4.2
70
31.5
36.5
40.5
47
55.5

4.8
80
31
36
40
46.5
55

5.4
90
30.5
35.5
39.5
45.5
54.5

6.0
100
30
35
39
45
53.5

6.6
110
29
34
38
44
53

7.5
125
28
33
37
43
52

8.4
140
26.5
31.5
36
41
50.5

9.6
160
24
29.5
34
38.5
48.5

10.8
180
21.5
27
31
36
46

12.0
200
18
24
28
32
43.5

13.2
220

15.0
250

20
24
28
40

22
33

DIMENSIONS AND WEIGHTS


TYPE
Single-phase

PORTS
Three-phase

ICn 150BM/160

ICn 150B/160

ICn 200AM/160

ICn 200A/160

ICn 300AR/160

ICn 300BM/200

ICn 300B/200

ICn 400A/200

DN1

11/2

DIMENSIONS mm

DN2

kg

h1

h2

n1

w1

w2

56

386

260

105

155

206

150

27.5

27.5

10

1
60

384/359
384

305

125

180

252

210

23.5

39.5

11

1~

3~

20.7

18.7

21.7

21.0

21.8

31.0

28.6

30.7

19

RANGE OF PERFORMANCE
Flow rate up to 250 l/min (15 m3/h)
Head up to 57 m
LIMITS OF USE
Manometric suction lift up to 7 m
Liquid temperature up to + 90C
Environment temperature up to + 40C

INSTALLATION AND USE


They are recommended for pumping clean water
and liquids that are chemically non aggressive to
the materials from which the pump is made.
THE pUmpS IN THIS serieS ARE MADE TO
STANDARDS en 733 - din 24255 AND ARE
SPECIFICALLY USED IN THE civil, industrial
oR agriCULTURAL SECTORS WHERE THEIR
CHARACTERISTICS OF STURDINESS AND RELIABILITY CAN BE BEST APPRECIATED.
The pumps must be installed in enclosed places, or
at least protected against inclement weather.
GUARANTEE 2 YEARS subject to our general
terms of sale.
CONSTRUCTION CHARACTERISTICS
PUMP BODY: cast iron, made to standards
EN733 - DIN 24255 and UNI 7467- NF E-44-111,
with threaded ports ISO 228/1.

IMPELLER: brass, of the type with centrifugal


radial flow.
MOTOR SHAFT:
stainless steelEN 10088-3 - 1.4104.
MECHANICAL SEAL:
ceramic - graphite - NBR.
ELECTRIC MOTOR: the pumps are close-coupled
to a carefully matched electric motor, quiet running, totally enclosed fan cooled, suitable for
continuous duty.
ICn M: single-phase 230 V - 50 Hz with capacitor
and thermal overload protector up to 1.5 kW.
ICn: three-phase 230/400 V - 50 Hz.
INSULATION: class F.
PROTECTION: IP 44.

CONSTRUCTION AND SAFETY STANDARDS


EN 60034-1
IEC 34-1
CEI 2-3

OPTIONS ON REQUEST
special mechanical seal
other voltages or frequency 60 Hz

DIMENSIONS
f

h1

DN1

h2

DN2

w1

w2

n1

20

ICH
centrifugal pumps - medium flow rates

ICH 300

ICH 200
ICH 150

H (m)

ICH 200A
ICH 100

ICH 150B

ICH 80

ICH 75

ICH 150A
ICH 100B
ICH 80C

ICH 50

Q
Q = Flow rate H = Total manometric head

Single-phase
ICH 50M
ICH 75M
ICH 80M
ICH 100M
ICH 150M
ICH 200M

ICH 80CM
ICH 100BM
ICH 150AM
ICH 150BM
ICH 200AM

TYPE

Three-phase
ICH 50
ICH 75
ICH 80
ICH 100
ICH 150
ICH 200
ICH 300
ICH 80C
ICH 100B
ICH 150A
ICH 150B
ICH 200A

Tolerance of the performance curves according to EN ISO 9906 App. A.

m3/h
POWER
kW
HP
l/min
0.37
0.50
0.55
0.75
0.60
0.85
0.75
1
1.1
1.5
1.5
2
H metres
2.2
3
0.60
0.85
0.75
1
1.1
1.5
1.1
1.5
1.5
2

0
0
9
12
18.2
21.2
29
33
39
12.5
13.7
14.5
20.2
22.5

3
50
8.5
11.5
17.2
20.2
28
32
38
-

6
100
8.2
11.2
16
19
26.5
30.5
36.5
12
13.2
13.8
19.2
22

9
150
7.5
10.6
14
17
24.5
28.5
34.5
11.7
13
13.5
19
21.5

12
200
6.3
9.6
11.5
14.5
22
26
32
11
12.5
13.2
18
21

15
250
4.9
8
9
11.6
18.5
22.5
28.5
10.2
11.6
12.6
17
20

18
300
2.8
6
5.4
8.4
15
19
25
9.2
10.5
11.8
16
18.5

21
350

24
400

30
500

8
9.2
10.5
14
16.6

6.5
8
9.2
12
14.5

5
6.5
7.5
10

36
600

DIMENSIONS AND WEIGHTS


TYPE
Single-phase
ICH 50M
ICH 75M
ICH 80M
ICH 100M
ICH 150M
ICH 200M

ICH 80CM
ICH 100BM
ICH 150AM
ICH 150BM
ICH 200AM

Three-phase
ICH 50
ICH 75
ICH 80
ICH 100
ICH 150
ICH 200
ICH 300
ICH 80C
ICH 100B
ICH 150A
ICH 150B
ICH 200A

PORTS
DN1
DN2

11/2

h1

200

82

118

300

225

92

48.5

373

269

60

332

238

11/2

DIMENSIONS mm
h2
n

45

f
276
283/276

kg
n1

165

135

133

190

160

114

155

216

171

12

97

141

196

10

386

260

110

150

206

12

14
160

51

11
1

1~
8.3
8.9
15.5
13.0
20.0
22.2
15.3
15.1
15.5
20.3
22.2

3~
8.2
8.4
15.1
12.1
19.3
21.6
22.8
14.2
14.3
15.2
19.5
21.8

21

RANGE OF PERFORMANCE
Flow rate up to 600 l/min (36 m3/h)
Head up to 39 m
LIMITS OF USE
Manometric suction lift up to 7 m
Liquid temperature up to + 90C
Environment temperature up to + 40C

INSTALLATION AND USE


THE ICH SERIES IS RECOMMENDED FOR civil,
agricULTURAL AND industrial APPLICATIONS. THE HIGH FLOW RATES AND CONTINUOUS RATING MAKE IT IDEAL FOR irrigaTion
WITH FLOWING AND SPRINKLING WATER, FOR
DRAWING WATER FROM LAKES, RIVERS, WELLS,
oR FOR industrial APPLICATIONS THAT NEED
TO ACHIEVE LARGE FLOW RATES AT MEDIUMLOW HEADS.
The pumps must be installed in enclosed places, or
at least protected against inclement weather.
GUARANTEE 2 YEARS subject to our general
terms of sale.
CONSTRUCTION CHARACTERISTICS
PUMP BODY: cast iron, with threaded ports
ISO228/1.
IMPELLER:
brass, of the type with centrifugal radial flow.

MOTOR SHAFT:
stainless steelEN 10088-3 - 1.4104.
MECHANICAL SEAL:
ceramic - graphite - NBR.
ELECTRIC MOTOR: the pumps are close-coupled to
a carefully matched electric motor, quiet running,
totally enclosed fan cooled, suitable for continuous
duty.
ICH M: single-phase 230 V - 50 Hz with capacitor
and thermal overload protector.
ICH: three-phase 230/400 V - 50 Hz.
INSULATION: class F.
PROTECTION: IP 44.
OPTIONS ON REQUEST
special mechanical seal
other voltages or frequency 60 Hz

CONSTRUCTION AND SAFETY STANDARDS


EN 60034-1
IEC 34-1
CEI 2-3

DIMENSIONS
f

h1

DN1

h2

DN2

n1

22

ICH
centrifugal pumps - high flow rates

ICH 550/8A

ICH 1000/30A

ICH 400/8B

ICH 300/6A

ICH 550/20A
ICH 750/30B
ICH 400/20B

H (m)

ICH 200/6B

ICH 150/6C
ICH 100/4

100

Q
Q = Flow rate H = Total manometric head

Single-phase
ICH100/4M
ICH150/6CM
ICH200/6BM

ICH150/6CRM
ICH200/6BRM

ICH400/8BM

ICH400/20BM

TYPE

Three-phase
ICH100/4
ICH150/6C
ICH200/6B
ICH300/6A
ICH150/6CR
ICH200/6BR
ICH300/6AR
ICH400/8B
ICH550/8A
ICH400/20B
ICH550/20A
ICH750/30B
ICH1000/30A

Tolerance of the performance curves according to EN ISO 9906 App. A.

POWER
kW
HP
0.75
1
1.1
1.5
1.5
2
2.2
3
1.1
1.5
1.5
2
2.2
3
3
4
4
5.5
3
4
4
5.5
5.5
7.5
7.5
10

m3/h
l/min

0
0
10
11.9
14.7
18.5
11.9
14.7
H metres 18.5
21.5
24.5
16
19
18
23

12
200
9.3
11.7
14.5
18.1
11.7
14.5
18.1
21
24
-

18
300
8.7
11.3
14
17.8
11.3
14
17.8
20.7
23.5
-

24
400
8
10.7
13.5
17.2
10.7
13.5
17.2
20
23
15.5
18.5
-

30
500
7
10.2
12.8
16.8
10.2
12.8
16.8
19.5
22.5
15.4
18.4
-

36
600
6
9.2
12
16
9.2
12
16
18.8
21.8
15.3
18.3
18
23

42
700
4.7
8
11
15
8
11
15
17.8
20.8
15.2
18.2
18
23

48
800
3
6.7
9.7
13.8
6.7
9.7
13.8
16.5
19.5
15
18
18
23

54
60
66
72
84
96 102 108 120 132
900 1000 1100 1200 1400 1600 1700 1800 2000 2200
5
8.2
12.2
5
8.2
12.2
15
18.3
14.5
17.5
18
23

3
6.7
10.5
3
6.7
10.5
13.5
16.8
14
17
18
23

5
8.3

5
8.3
6
11.2
9
15
13
13
12
9
16.2 15.2 12
17.5 17 16.5
22.5 22.5 22.5

4.8
7.8
15.5
22

2
5
15
21.5

2
14.5
21

13
19.5

18

DIMENSIONS AND WEIGHTS


TYPE
Single-phase
ICH100/4M
ICH150/6CM
ICH200/6BM

ICH150/6CRM
ICH200/6BRM

ICH400/8BM

ICH400/20BM

Three-phase
ICH100/4
ICH150/6C
ICH200/6B
ICH300/6A
ICH150/6CR
ICH200/6BR
ICH300/6AR
ICH400/8B
ICH550/8A
ICH400/20B
ICH550/20A
ICH750/30B
ICH1000/30A

PORTS
DN1
DN2
21/2 21/2
3

a
55

f
323

68

411

70

413

80

429
462
429
462

h
240

h1
97

120

82

585

DIMENSIONS mm
h2
n
143
190

192

240

312

w
0

s
10

12

30

14

190
132

370

kg
n1
155

160

180
210

245
292

212

1~
15.6
28.1
29.1
29.7
32.0
41.0
40.5
-

3~
14.2
26.2
28.5
29.4
29.2
31.4
32.3
36.1
41.0
35.3
40.5
60.9
65.2

23

RANGE OF PERFORMANCE
Flow rate up to 1800 l/min (108 m3/h)
Head up to 24.5 m
LIMITS OF USE
Manometric suction lift up to 7 m
Liquid temperature up to + 90C
Environment temperature up to + 40C

INSTALLATION AND USE


THE ICH SERIES IS RECOMMENDED FOR USE in
THE civil, agricULTURAL AND industrial
FIELD. THE HIGH FLOW RATES AND CONTINUOUS RATING MAKE IT IDEAL FOR irrigaTion
WITH FLOWING AND SPRINKLING WATER, FOR
DRAWING WATER FROM LAKES, RIVERS, WELLS,
oR FOR industrial APPLICATIONS THAT NEED
TO ACHIEVE LARGE FLOW RATES AT MEDIUMLOW HEADS.
The pumps must be installed in enclosed places, or
at least protected against inclement weather.
GUARANTEE 2 YEARS subject to our general
terms of sale.
CONSTRUCTION CHARACTERISTICS
PUMP BODY: cast iron, with threaded ports
ISO228/1.
IMPELLER: brass (cast iron for ICH/30), of the
type with centrifugal radial flow.

MOTOR SHAFT:
stainless steelEN 10088-3 - 1.4104.
MECHANICAL SEAL:
ceramic - graphite - NBR.
ELECTRIC MOTOR: the pumps are close-coupled
to a carefully matched electric motor, quiet running, totally enclosed fan cooled, suitable for
continuous duty.
ICH M: single-phase 230 V - 50 Hz with capacitor
and thermal overload protector.
ICH: three-phase 230/400 V - 50 Hz.
INSULATION: class F.
PROTECTION: IP 44.
OPTIONS ON REQUEST
special mechanical seal
other voltages or frequency 60 Hz

CONSTRUCTION AND SAFETY STANDARDS


EN 60034-1
IEC 34-1
CEI 2-3

DIMENSIONS
f

DN2

h1

DN1

h2

n1

24

NCO
centrifugal pumps with open impeller

NCO100

H (m)

NCO75

Q
Q = Flow rate H = Total manometric head

TYPE
Single-phase

Tolerance of the performance curves according to EN ISO 9906 App. A.

POWER
Three-phase

kW

HP

NCO 75M

NCO 75

0.55

0.75

NCO 100M

NCO 100

0.75

m3/h
l/min
H metres

12

15

18

19.5

21

50

100

150

200

250

300

325

350

18
20

17
19.5

16
18

14.5
16.5

13
15

10.5
12.5

8
10

6
8

DIMENSIONS AND WEIGHTS


TYPE
Single-phase

PORTS
Three-phase

NCO 75M

NCO 75

NCO 100M

NCO 100

DIMENSIONS mm

kg

DN1

DN2

h1

h2

n1

11/2

11/2

41

297

227

92

135

190

160

50

10

1~

3~

12.7

11.8

12.8

11.9

25

RANGE OF PERFORMANCE
Flow rate up to 350 l/min (21 m3/h)
Head up to 20 m
LIMITS OF USE
Manometric suction lift up to 7 m
Liquid temperature up to + 90C
Liquid temperature up to + 40C in
the NCOX version (with technopolymer
impeller)
Environment temperature up to + 40C
Passage of solid bodies 10 mm
INSTALLATION AND USE
They are recommended for pumping water and
liquids that are chemically non aggressive to the
materials from which the pump is made. THE OPEN
IMPELLER DESIGN ALLOWS THE PUMPING OF
LIQUIDS WITH RELATIVELY HIGH LEVELS OF
IMPURITIES WITHOUT RISK OF CLOGGING THE
IMPELLER. FOR THIS REASON THE NCO SERIES
ARE SUITABLE FOR USE IN INDUSTRY, FOR THE
TRANSFER OF WATER FROM CANALS, RIVERS,
RESERVOIRS, TANKS, ETC. The pumps must be
installed in enclosed places, or at least protected
against inclement weather.

CONSTRUCTION CHARACTERISTICS
PUMP BODY: cast iron, with threaded ports
ISO228/1.
BODY BACK-PLATE:
stainless steel AISI 304.
OPEN IMPELLER: stainless steel AISI 316.
MOTOR SHAFT:
stainless steelEN 10088-3 - 1.4104.
MECHANICAL SEAL:
ceramic - graphite - NBR.
ELECTRIC MOTOR: the pumps are close-coupled
to a carefully matched electric motor, quiet running, totally enclosed fan cooled, suitable for
continuous duty.
NCO M: single-phase 230V-50 Hz with capacitor
and thermal overload protector.
NCO: three-phase 230/400 V - 50 Hz.

GUARANTEE 2 YEARS subject to our general


terms of sale.

INSULATION: class F.
PROTECTION: IP 44.
OPTIONS ON REQUEST
impeller in technopolymer
(NCO M...X - NCO...X)
special mechanical seal
other voltages or frequency 60 Hz

CONSTRUCTION AND SAFETY STANDARDS


EN 60034-1
IEC 34-1
CEI 2-3

DIMENSIONS
f
a

h1

DN1

h2

DN2

n1

26

PRO-NCO
stainless steel pumps

PRO-NCO 100

H (m)

PRO-NCO 75

Q
Q = Flow rate H = Total manometric head

TYPE
Single-phase
PRO-NCO 75M
PRO-NCO 100M

Three-phase
PRO-NCO 75
PRO-NCO 100

Tolerance of the performance curves according to EN ISO 9906 App. A.

POWER
m3/h
l/min
kW
HP
0.55
0.75
H metres
0.75
1.00

0
0
18
20

3
50
17
19.5

6
100
16
18

9
150
14.5
16.5

12
200
13
15

15
250
10.5
12.5

18
300
8
10

19.5
325
6
8

21
350
6

DIMENSIONS AND WEIGHTS


TYPE
Single-phase

PORTS
Three-phase

PRO-NCO 75M

PRO-NCO 75

PRO-NCO 100M

PRO-NCO 100

kg

DN1

DN2

h1

h2

n1

11/2

11/2

41

297

227

92

135

190

160

50

10

1~

3~

13.0

12.0

13.1

12.1

27

RANGE OF PERFORMANCE
Flow rate up to 350 l/min (21 m3/h)
Head up to 20 m
LIMITS OF USE
Manometric suction lift up to 7 m
Liquid temperature up to + 90C
Environment temperature up to + 40C
Passage of solid bodies 10 mm

INSTALLATION AND USE


They are recommended for pumping water and
liquids that are chemically non aggressive to the
materials from which the pump is made. THE
OPEN IMPELLER DESIGN ALLOWS THE PUMPING
OF LIQUIDS WITH RELATIVELY HIGH LEVELS OF
IMPURITIES WITHOUT RISK OF CLOGGING THE
IMPELLER. FOR THIS REASON THE PRO-NCO
SERIES ARE SUITABLE FOR USE IN SYSTEMS FOR
WASHING FRUIT, VEGETABLES, FISH, SHELLFISH,
MEAT, IN INDUSTRIAL SYSTEMS FOR WASHING
METAL PARTS, GLASS CONTAINERS, AND FOR THE
CIRCULATION OF COOLING LIQUIDS.
The pumps must be installed in enclosed places, or
at least protected against inclement weather.

CONSTRUCTION CHARACTERISTICS
PUMP BODY: stainless steel AISI 316, with
threaded ports ISO228/1.
BODY BACK-PLATE:
stainless steel AISI 316.
OPEN IMPELLER: stainless steel AISI 316.
MOTOR SHAFT: stainless steel AISI 316.
MECHANICAL SEAL:
ceramic - graphite - viton - AISI 316
ELECTRIC MOTOR: the pumps are close-coupled
to a carefully matched electric motor, quiet running, totally enclosed fan cooled, suitable for
continuous duty.
PRO-NCO M: single-phase 230 V - 50 Hz with
capacitor and thermal overload protector.
PRO-NCO: three-phase 230/400 V - 50 Hz.
INSULATION: class F.
PROTECTION: IP 44.

GUARANTEE 2 YEARS subject to our general


terms of sale.

OPTIONS ON REQUEST
special mechanical seal
other voltages or frequency 60 Hz
protection IP 55

CONSTRUCTION AND SAFETY STANDARDS


EN 60034-1
IEC 34-1
CEI 2-3

DIMENSIONS
f
a

h1

DN1

h2

DN2

n1

28

ICB

H (m)

H (feet)

two stage centrifugal pumps

ICB 200
ICB 150H
ICB 100N

ICB 300A
ICB 200B
ICB 150M

ICB 1000A/32
ICB 750B/32
ICB 550B/32
ICB 400C/32

ICB 1000A/40
ICB 750B/40
ICB 550C/40

29

Two stage pumps recognised for their


high efficiency, versatility and quiet
running.
RANGE OF PERFORMANCE
Flow rate up to 400 l/min (24 m3/h)
Head up to 112 m
LIMITS OF USE
Manometric suction lift up to 7 m
Liquid temperature up to + 90C
Liquid temperature up to + 40C in
the ICBX version (with technopolymer
impeller)
Environment temperature up to + 40C

INSTALLATION AND USE


They are recommended for pumping clean water
and liquids that are chemically non aggressive to
the materials from which the pump is made.
THEIR HIGH EFFICIENCY AND ADAPTABILITY TO
THE MOST VARIED, EVEN UNUSUAL APPLICATIONS, MAKE THEM THE IDEAL CHOICE IN THE
domestic, civil AND industrial FIELD; in
particULAR FOR distribuTING WATER in
COMBINATION WITH PRESSURE SETS, FOR
INCREASING PRESSURE IN THE MAINS, FOR
FIRE-FIGHTING SETS.
The pumps must be installed in enclosed places, or
at least protected against inclement weather.
GUARANTEE 2 YEARS subject to our general
terms of sale.
CONSTRUCTION CHARACTERISTICS
MOTOR SHAFT:
stainless steelEN 10088-3 - 1.4104.
MECHANICAL SEAL:
ceramic - graphite - NBR.
ELECTRIC MOTOR: the pumps are close-coupled
to a carefully matched electric motor, with high
efficiency (class EFF1 for powers from 4 to 7.5

kW), quiet running, totally enclosed fan cooled,


suitable for continuous duty.
ICB M: single-phase 230 V - 50 Hz with capacitor
and thermal overload protector (up to 1.5 kW).
ICB: three-phase 230/400 V - 50 Hz up to 4 kW.
400/690 V - 50 Hz from 5.5 to 7.5 kW.
INSULATION: class F.
PROTECTION: IP 44.

special mechanical seal


other voltages or frequency 60 Hz

ICB 100N
PUMP BODY: cast iron, with threaded ports
ISO228/1.
BODY BACK-PLATE:
stainless steel AISI 304.
IMPELLERS: stainless steel AISI 304 of the type
with centrifugal radial flow.
Other ICB
PUMP BODY: cast iron, with threaded ports
ISO228/1.
IMPELLERS: brass, of the type with centrifugal
radial flow.
OPTIONS ON REQUEST
impeller in technopolymer
(ICB M...X - ICB...X)

CONSTRUCTION AND SAFETY STANDARDS


EN 60034-1
IEC 34-1
CEI 2-3

30

ICB
two stage centrifugal pumps

ICB200

H (feet)

H (m)

ICB150H

ICB100N

ICB150H
ICB100N

(m)

NPSH (m)

NPSH (feet)

ICB200

ICB200

P2 (HP)

P2 (kW)

ICB150H

ICB100N

Q = Flow rate H = Total manometric head

TYPE
Single-phase
ICB 100NM
ICB 150HM
ICB 200M

Three-phase
ICB 100N
ICB 150H
ICB 200

POWER
kW
HP
0.75
1
1.1
1.5
1.5
2

Tolerance of the performance curves according to EN ISO 9906 App. A.

m3/h
l/min
H metres

0
0
42
54
66

1.2
20
39
53
64

1.8
30
37
51
62

2.4
40
34
49
60

3.0
50
31
46
57

3.6
60
28.5
42
53

4.2
70
25.5
38
49

4.8
80
22
34
44

5.4
90
18
29
39.5

6.0
100
15
24
35

6.6
110

30

31

ICB
two stage centrifugal pumps

ICB300A

H (feet)

H (m)

ICB200B

ICB150M

ICB200B

ICB300A

(m)

NPSH (m)

NPSH (feet)

ICB150M

ICB300A

P2 (HP)

P2 (kW)

ICB200B
ICB150M

Q = Flow rate H = Total manometric head

TYPE
Single-phase
ICB 150MM
ICB 200BM

Three-phase
ICB 150M
ICB 200B
ICB 300A

POWER
kW
HP
1.1
1.5
1.5
2
2.2
3

Tolerance of the performance curves according to EN ISO 9906 App. A.

m3/h
l/min
H metres

0
0
47
58
68

1.2
20
46
56
66.5

1.8
30
45.5
55
65.5

2.4
40
44
54
65

3.0
50
43
53
63

3.6
60
42
52
62

4.2
70
41
50
60

4.8
80
38
48
58

5.4
90
36
46
56

6.0
100
34
44
54

6.6
110
31
41
51

7.5
125
27
37
47

8.4
140
22
33
42

9.6
160

10.8
180

26
35

28

32

ICB
two stage centrifugal pumps

ICB550B/32

(m)

NPSH (m)

NPSH (feet)

H (m)

H (feet)

ICB400C/32

ICB550B/32

P2 (HP)

P2 (kW)

ICB400C/32

Q = Flow rate H = Total manometric head

TYPE
Single-phase
ICB 400C/32M

Three-phase
ICB 400C/32
ICB 550B/32

POWER
kW
HP
3
4
4
5.5

Tolerance of the performance curves according to EN ISO 9906 App. A.

m3/h
l/min
H metres

0
0
70
85

2.4
40
66.5
81

3.0
50
65.5
80

3.6
60
65
79

4.2
70
64
78

4.8
80
63
77

5.4
90
62
76

6.0
100
60.5
75

6.6
110
59
74

7.5
125
57
72

8.4
140
55
69

9.6
160
52
66

10.8
180
49.5
62

12.0
200
46.5
58

15.0
250
36
49

33

ICB
two stage centrifugal pumps

ICB1000A/32

(m)

NPSH (m)

NPSH (feet)

H (m)

H (feet)

ICB750B/32

ICB1000A/32

P2 (HP)

P2 (kW)

ICB750B/32

Q = Flow rate H = Total manometric head

Three-phase
ICB 750B/32
ICB 1000A/32

POWER
kW
HP
5.5
7.5
7.5
10

m3/h
l/min
H metres

Tolerance of the performance curves according to EN ISO 9906 App. A.

0
0
94
112

2.4
40
94
111

3.0
50
93.5
110.8

3.6
60
93
110.5

4.2
70
92
110.3

4.8
80
91
110

5.4
90
90
109

6.0
100
89
108

6.6
110
87
107

7.5
125
85
105

8.4
140
83
102

9.6
160
79
99

10.8
180
75
94

12.0
200
70
89

15.0
250
56
74

34

ICB
two stage centrifugal pumps

ICB1000A/40

H (feet)

ICB550C/40

ICB1000A/40
ICB750B/40

(m)

NPSH (m)

ICB550C/40

NPSH (feet)

H (m)

ICB750B/40

ICB1000A/40
ICB750B/40
P2 (HP)

P2 (kW)

ICB550C/40

Q = Flow rate H = Total manometric head

TYPE
Three-phase
ICB 550C/40
ICB 750B/40
ICB 1000A/40

POWER
kW
HP
4
5.5
5.5
7.5
7.5
10

m3/h
l/min
H metres

Tolerance of the performance curves according to EN ISO 9906 App. A.

0
0
64
76
88

6.0
100
62
73
85

6.6
110
61
72.5
84.5

7.5
125
60
72
84

8.4
140
59
71
83

9.6
160
58
70
82

10.8
180
56
69
81

12.0
200
54.5
67.5
79.5

15.0
250
49
64
76

18.0
300
43
59.5
72

21.0
350
35
54
67

24.0
400
46
60

35

ICB
two stage centrifugal pumps
DIMENSIONS AND WEIGHTS

h1

DN1

h2

DN2

TYPE
Single-phase

PORTS
Three-phase

ICB 100NM

ICB 100N

ICB 150HM

ICB 150H

ICB 200M

ICB 200

ICB 150MM

ICB 150M

ICB 200BM

ICB 200B

ICB 300A

ICB 400C/32M

ICB 400C/32

ICB 550B/32

ICB 750B/32

ICB 1000A/32

ICB 550C/40

ICB 750B/40

ICB 1000A/40

DN1

n1

DIMENSIONS mm

DN2

11/4
1

11/2

kg

h1

h2

n1

73

330

201

92

109

180

142

74

382

225

93

132

200

162

23

84

405

263

110

153

225

185

26

11

24.8

24.1

74

382

225

93

132

200

162

23

10

20.1

19.2

86

407

263

110

153

225

185

26

11

24.6

25.2

26.1

95

464

304

132

172

266

206

s
10

19

11/4
542
2

108
11/2

496
542

14
334

139

195

292

232

21

1~

3~

14.5

14.0

20.1

19.4

42.9

39.1

42.9

56.0

61.7

49.8

55.1

60.8

36

MSG
multi-stage centrifugal pumps

MSG08

MSG10

H (m)

MSG07

MSG08L

MSG05

Q
Q = Flow rate H = Total manometric head

TYPE
Single-phase
MSG 05M
MSG 07M
MSG 08M
MSG 08LM
MSG 10M

Three-phase
MSG 05
MSG 07
MSG 08
MSG 08L
MSG 10

Tolerance of the performance curves according to EN ISO 9906 App. A.

POWER
m3/h
l/min
kW
HP
0.37
0.50
0.45
0.60
0.60
0.85 H metres
0.60
0.85
0.75
1

0
0
27
38
50
36
46

0.3
5
26
36
48
35.5
45

0.6
10
25
35
47
35
44

0.9
15
24
34
45
34
43

1.2
20
22.5
33.5
43
33.5
42

1.5
25
21
31
40.5
32.5
41

1.8
30
20
29
38.5
32
40

2.4
40
16.5
25
33.5
30
38

3.0
50
13
20
28
28
35.5

3.6
60
9
15.5
22.5
26
33

4.2
70
5
10
16
23
30

4.8
80

5.4
90

6.0
100

6.6
110

7.2
120

7.8
130

5
10
20
26.5

17
22.5

13.5
19

10
15

5
10

DIMENSIONS AND WEIGHTS


TYPE
Single-phase

PORTS
Three-phase

DN1

DIMENSIONS mm

DN2

110

334

135

367/359

MSG 05M

MSG 05

MSG 07M

MSG 07

MSG 08M

MSG 08

MSG 08LM

MSG 08L

110

342/334

MSG 10M

MSG 10

135

378

172

191

h1

134

h2

38

61

kg
n

158

n1

116

1~

3~

8.6

8.6

9.4

8.9

10.8

10.2

10.2

9.4

13.4

12.3

37

RANGE OF PERFORMANCE
Flow rate up to 130 l/min (7.8 m3/h)
Head up to 50 m
LIMITS OF USE
Manometric suction lift up to 7 m
Liquid temperature up to + 40C
Environment temperature up to + 40C

INSTALLATION AND USE


They are recommended for pumping clean water
and liquids that are chemically non aggressive to
the materials from which the pump is made.
DUE TO THEIR RELIABILITY, QUIET running
and LOW maintenance, they are SUITABLE
FOR domestic APPLICATIONS INCLUDING WATER SUPPLIES (AS A PRESSURE SET), GARDEN
IRRIGATION, etc.
The pumps must be installed in enclosed places, or
at least protected against inclement weather.

flow, made of technopolymer (approved for


drinking water).
MOTOR SHAFT:
stainless steelEN 10088-3 - 1.4104
MECHANICAL SEAL:
ceramic - graphite - NBR.
ELECTRIC MOTOR: the pumps are close-coupled
to a carefully matched electric motor, quiet running, totally enclosed fan cooled, suitable for
continuous duty.
MSG M: single-phase 230 V - 50 Hz with capacitor
and thermal overload protector.
MSG: three-phase 230/400 V - 50 Hz.
INSULATION: class F.
PROTECTION: IP 44.

GUARANTEE 2 YEARS subject to our general


terms of sale.
CONSTRUCTION CHARACTERISTICS
PUMP BODY: cast iron, with threaded ports
ISO228/1.
BODY BACK-PLATE:
stainless steel AISI 304.
IMPELLERS: of the type with centrifugal radial

CONSTRUCTION AND SAFETY STANDARDS


EN 60 335-1
EN 60034-1
IEC 335-1
IEC 34-1
CEI 61-150
CEI 2-3

OPTIONS ON REQUEST
other voltages or frequency 60 Hz

DIMENSIONS
f

h1

DN1

h2

DN2

w
n1

38
stainless steel pump body

MS 07-08
multi-stage centrifugal pumps

MS08

MS07

H (m)

MS08L

Q
Q = Flow rate H = Total manometric head

TYPE
Single-phase
MS 07M
MS 08M
MS 08LM

Three-phase
MS 07
MS 08
MS 08L

Tolerance of the performance curves according to EN ISO 9906 App. A.

POWER
m3/h
l/min
kW
HP
0.45
0.60
0.60
0.85 H metres
0.60
0.85

0
0
38
50
36

0.3
5
36
48
35.5

0.6
10
35
47
35

0.9
15
34
45
34

1.2
20
32.5
43
33.5

1.5
25
31
40.5
32.5

1.8
30
29
38.5
32

2.4
40
25
33.5
30

3.0
50
20
28
28

3.6
60
15.5
22.5
25.5

4.2
70
10
16
23

4.8
80
5
10
20

5.4
90

6.0
100

6.6
110

7.2
120

17

13.5

10

DIMENSIONS AND WEIGHTS


TYPE
Single-phase

PORTS
Three-phase

MS 07M

MS 07

MS 08M

MS 08

MS 08LM

MS 08L

DIMENSIONS mm

DN1

DN2

90

kg

h1

h2

n1

174

122

52

160

120

95

345
353/345

1~

3~

6.9

6.3

7.6

6.9

7.5

6.9

39

RANGE OF PERFORMANCE
Flow rate up to 120 l/min (7.2 m3/h)
Head up to 50 m
LIMITS OF USE
Manometric suction lift up to 7 m
Liquid temperature up to + 40C
Environment temperature up to + 40C

INSTALLATION AND USE


They are recommended for pumping clean water
and liquids that are chemically non aggressive to
the materials from which the pump is made.
DUE TO THEIR RELIABILITY AND QUIET running, they are SUITABLE FOR domestic APPLICATIONS INCLUDING WATER SUPPLIES (AS A
PRESSURE SET), GARDEN IRRIGATION, etc.
The pumps must be installed in enclosed places, or
at least protected against inclement weather.
GUARANTEE 2 YEARS subject to our general
terms of sale.
CONSTRUCTION CHARACTERISTICS
PUMP BODY: stainless steel AISI 304, with
threaded ports ISO228/1.
BODY BACK-PLATE:
stainless steel AISI 304.
IMPELLERS: of the type with centrifugal radial
flow, made of technopolymer (approved for

drinking water).
MOTOR SHAFT:
stainless steelEN 10088-3 - 1.4104.
MECHANICAL SEAL:
ceramic - graphite - NBR.
ELECTRIC MOTOR: the pumps are close-coupled
to a carefully matched electric motor, quiet running, totally enclosed fan cooled, suitable for
continuous duty.
MS M: single-phase 230 V - 50 Hz with capacitor
and thermal overload protector.
MS: three-phase 230/400 V - 50 Hz.
INSULATION: class F.
PROTECTION: IP 44.
OPTIONS ON REQUEST
special mechanical seal
other voltages or frequency 60 Hz

CONSTRUCTION AND SAFETY STANDARDS


EN 60 335-1
EN 60034-1
IEC 335-1
IEC 34-1
CEI 61-150
CEI 2-3

DIMENSIONS
f

h1

DN1

h2

DN2

n1

40

VMS A
vertical multi-stage pumps

VMS A25

VMS A20

H (m)

VMS A15

VMS A10
VMS A07
VMS A06

Q
Q = Flow rate H = Total manometric head

TYPE
Single-phase
VMS A 06M
VMS A 07M
VMS A 10M
VMS A 15M
VMS A 20M
VMS A 25M

Three-phase

VMS A 10
VMS A 15
VMS A 20
VMS A 25

Tolerance of the performance curves according to EN ISO 9906 App. A.

POWER
kW
HP
0.45
0.6
0.55
0.75
0.75
1
1.1
1.5
1.5
2
1.8
2.5

m3/h
l/min

H metres

0
0
36
48
60
75
90
105

0.6
10
35
46
58
72
87
102

1.2
20
33
44
55
70
83
98

1.8
30
31
41
51
66
78
92

2.4
40
28
37.5
47
61
73
85

2.7
45
26
35
44
58
70
82

3.0
50
25
34
42
55
66
78

3.3
55
23
31
38
52
62
73

3.6
60
22
29
36
48
58
68

3.9
65
20
26
32
44
53
63

4.2
70
18
23
28
40
48
57

w1

w2

4.5
75
16
19.5
23
35
44
50

4.8
80
14
16
18
30
38
45

DIMENSIONS AND WEIGHTS


TYPE
Single-phase

PORTS
Three-phase

VMS A 06M

VMS A 07M

VMS A 10M

VMS A 10

VMS A 15M

VMS A 15

VMS A 20M

VMS A 20

VMS A 25M

VMS A 25

DN1

DN2

N
stages

DIMENSIONS mm
a

3
11/4

4
11/4

11/2

h1

3~

382

10.9

456

13.0

530

480

16.3

14.8

603

543

24.1

22.4

506
81

100

200

66

223

kg
1~

432
90

5
6

633
708

50

60

h2

183

62

88.5

11

573

25.0

23.4

648

30.8

26.7

41

RANGE OF PERFORMANCE
Flow rate up to 80 l/min (4.8 m3/h)
Head up to 105 m
LIMITS OF USE
Manometric suction lift up to 7 m
Liquid temperature up to + 40C
INSTALLATION AND USE
They are recommended for pumping clean water
and liquids that are chemically non aggressive to
to the materials from which the pump is made.
THEIR RELIABILITY and QUIET running MAKE
THEM SUITABLE FOR domestic and CIVIL
APPLICATIONS. BECAUSE THE PUMP IS FULLY
SUBMERSIBLE WITH THE MOTOR COOLED BY
THE PUMPED LIQUID, IT CAN BE USED SAFELY
IN WET ENVIRONMENTS AND IN SPACES WITH
INSUFFICIENT VENTILATION.
GUARANTEE 2 YEARS subject to our general terms
of sale.
CONSTRUCTION CHARACTERISTICS
OUTER CASE AND MOTOR SUPPORT: stainless steel AISI 304 case with threaded ports
ISO2281.
IMPELLERS AND DIFFUSERS: technopolymer.
DIAPHRAGMS: stainless steel AISI 304, complete with anti-wear rings.

MOTOR SHAFT:
stainless steelEN 10088-3 -1.4104.
DOUBLE SEAL: mechanical seal silicon carbide-ceramic-NBR with oil barrier chamber and
inner lip seal to protect the seal in the event of dry
running.
SCREWS: stainless steel AISI 304.
MOTOR: electric, asynchronous for continuous
duty.
VMS A M: single-phase 220240 V - 50 Hz with
thermal overload protector built into windings
below 1.5 kW. The 1.8 kW motor has an external
overload protector (with manual reset) incorporated into the control box.
VMS A: three-phase 380415 V - 50 Hz.
INSULATION: class F.
PROTECTION: IP 68.
STANDARD FEATURES:
VMS A M: (single-phase)
2 m power cable type H07 RN-F with removable
connector.
Control box with capacitor and Schuko plug
VMS A: (three-phase)
2 m power cable type H07 RN-F with removable
connector.

CONSTRUCTION AND SAFETY STANDARDS


EN 60 335-1
EN 60034-1
IEC 335-1
IEC 34-1
CEI 61-150
CEI 2-3

OPTIONS ON REQUEST
other voltages or frequency 60 Hz

DIMENSIONS
a
DN2

SINGLE-PHASE CONTROL BOX


VMS

h1

DN1

h2

VMS

s
w1

w1
n

w2

w2
f

42

VMS B
vertical multi-stage pumps

VMS B30

VMS B25

H (m)

VMS B20

VMS B15
VMS B10
VMS B07
VMS B06

Q
Q = Flow rate H = Total manometric head

TYPE
Single-phase
VMS B 06M
VMS B 07M
VMS B 10M
VMS B 15M
VMS B 20M
VMS B 25M
VMS B 30M

Three-phase

VMS B 10
VMS B 15
VMS B 20
VMS B 25
VMS B 30

Tolerance of the performance curves according to EN ISO 9906 App. A.

POWER
kW
HP
0.45
0.6
0.55
0.75
0.75
1
1.1
1.5
1.5
2
1.8
2.5
2.2
3

m3/h
l/min

H metres

0
0
30
40
50
60
75
90
105

1.2
20
27
37
48
56
72
85
101

1.8
30
26
36
46
54
69
83
98

2.4
40
25
34.5
44
52
66
79
94

3.0
50
24
32.5
41
50
64
76
90

3.6
60
22.5
30
38
48
60
73
86

4.2
70
20.5
28
35
46
57
68
80

4.8
80
18
25
32
43
53
64
75

5.4
90
15.5
21.5
28
39
48
58
67

6.0
100
13
18.5
24
36
43
52
60

6.6
110
10
14.5
19
31
38
44
52

7.2
120
7
10
14
24
32
38
44

DIMENSIONS AND WEIGHTS


TYPE
Single-phase

PORTS
Three-phase

VMS B 06M

VMS B 07M

VMS B 10M

VMS B 10

VMS B 15M

VMS B 15

VMS B 20M

VMS B 20

VMS B 25M

VMS B 25

VMS B 30M

VMS B 30

DN1

DN2

N
stages

DIMENSIONS mm
a

3
11/4

506

11/2

6
7

50

530

4
5

h1

432
90

5
11/4

81
100

200

66

223

kg
h2

1~

3~

382

10.9

456

13.0

480

16.3

14.8

513

23.0

21.0

543

24.1

22.4

573

25.0

23.4

648

30.7

26.7

708

88.5

573
60

62

w2

603
633

183

w1

11

43

RANGE OF PERFORMANCE
Flow rate up to 120 l/min (7.2 m3/h)
Head up to 105 m
LIMITS OF USE
Manometric suction lift up to 7 m
Liquid temperature up to + 40C
INSTALLATION AND USE
They are recommended for pumping clean water
and liquids that are chemically non aggressive to
the materials from which the pump is made.
THEIR RELIABILITY and QUIET running MAKE
THEM SUITABLE FOR domestic and CIVIL
APPLICATIONS, BECAUSE THE PUMP IS FULLY
SUBMERSIBLE WITH THE MOTOR COOLED BY
THE PUMPED LIQUID, IT CAN BE USED SAFELY
IN WET ENVIRONMENTS AND IN SPACES WITH
INSUFFICIENT VENTILATION.
GUARANTEE 2 YEARS subject to our general terms
of sale.
CONSTRUCTION CHARACTERISTICS
OUTER CASE AND MOTOR SUPPORT: stainless steel AISI 304 case with threaded ports
ISO2281.
IMPELLERS AND DIFFUSERS: technopolymer.
DIAPHRAGMS: stainless steel AISI 304, complete with anti-wear rings.

MOTOR SHAFT:
stainless steelEN 10088-3-1.4104.
DOUBLE SEAL: mechanical seal silicon carbide-ceramic-NBR, with oil barrier chamber
and inner lip seal to protect the seal in the event
of dry running.
SCREWS: stainless steel AISI 304.
MOTOR: electric, asynchronous for continuous
duty.
VMS B M: single-phase 220240 V - 50 Hz with
thermal overload protector built into windings
below 1.5 kW. The 1.8 kW motor has an external
overload protector (with manual reset) incorporated into the control box.
VMS B: three-phase 380415 V-50 Hz.
INSULATION: class F.
PROTECTION: IP 68.
STANDARD FEATURES:
VMS B M: (single-phase)
2 m power cable type H07 RN-F with removable
connector.
Control box with capacitor and Schuko plug
VMS B: (three-phase)
2 m power cable type H07 RN-F with removable
connector.
OPTIONS ON REQUEST
other voltages or frequency 60 Hz

CONSTRUCTION AND SAFETY STANDARDS


EN 60 335-1
EN 60034-1
IEC 335-1
IEC 34-1
CEI 61-150
CEI 2-3

DIMENSIONS
a
DN2

SINGLE-PHASE CONTROL BOX


VMS

h1

DN1

h2

VMS

w1

s
w1

w2

w2
f

44

VMSE A
in-line multi-stage pumps

VMSEA25

VMSEA20

H (m)

VMSEA15

VMSEA10
VMSEA07M
VMSEA06M

Q
Q = Flow rate H = Total manometric head

TYPE
Single-phase Three-phase
VMSE A 06M
VMSE A 07M
VMSE A 10M VMSE A 10
VMSE A 15M VMSE A 15
VMSE A 20M VMSE A 20
VMSE A 25M VMSE A 25

POWER
kW
HP
0.45 0.6
0.55 0.75
0.75
1
1.1
1.5
1.5
2
1.8
2.5

Tolerance of the performance curves according to EN ISO 9906 App. A.

0
0
36
48
60
75
90
105

m3/h
l/min

H
metres

0.6
10
35
46
58
72
87
102

1.2
20
33
44
55
70
83
98

1.8
30
31
41
51
66
78
92

2.4
40
28
37.5
47
61
73
85

2.7
45
26
35
44
58
70
82

3.0
50
25
34
42
55
66
78

3.3
55
23
31
38
52
62
73

3.6
60
22
29
36
48
58
68

3.9
65
20
26
32
44
53
63

4.2
70
18
23
28
40
48
57

4.5
75
16
19.5
23
35
44
50

4.8
80
14
16
18
30
38
45

DIMENSIONS AND WEIGHTS


TYPE
Single-phase

PORTS
Three-phase

DN

DIMENSIONS mm
N stages

VMSE A 06M

VMSE A 07M

VMSE A 10M

VMSE A 10

VMSE A 15M

VMSE A 15

VMSE A 20M

VMSE A 20

VMSE A 25M

VMSE A 25

11/4

135

153

kg
1~

3~

397

8.4

471

10.5

495

13.8

12.3

20.6

18.9

547

81

200

66

577

21.5

19.9

652

27.3

23.2

45

RANGE OF PERFORMANCE
Maximum flow rate 80 l/min (4.8 m3/h)
Head up to 105 m

DIAPHRAGMS: stainless steel AISI 304, complete with anti-wear rings.


MOTOR SHAFT:
stainless steelEN 10088-3 -1.4104.
DOUBLE SEAL: mechanical seal silicon carbide-ceramic-NBR, with oil barrier chamber
and inner lip seal to protect the seal in the event
of dry running.
SCREWS: stainless steel AISI 304.
MOTOR: electric, asynchronous for continuous
duty.
VMSE A M: single-phase 220240 V - 50 Hz with
thermal overload protector built into windings
below 1.5 kW. The 1.8 kW motor has an external
overload protector (with manual reset) incorporated into the control box.
VMSE A: three-phase 380415 V-50Hz.
INSULATION: class F.
PROTECTION: IP 68.

LIMITS OF USE
Manometric suction lift up to 7 m
Liquid temperature up to + 40C
INSTALLATION AND USE
They are recommended for pumping clean water
and liquids that are chemically non aggressive
to the materials from which the pump is made.
THEIR RELIABILITY AND QUIET running MAKE
THEM SUITABLE FOR domestic and CIVIL APPLICATIONS AND, BECAUSE THE PUMP IS FULLY
SUBMERSIBLE WITH THE MOTOR COOLED BY
THE PUMPED LIQUID, IT CAN BE USED SAFELY IN
WET AREAS AND IN SPACES WITH INSUFFICIENT
VENTILATION. THE ENCLOSED DESIGN ALSO
ELIMINATES THE POSSIBILITY OF WATER ESCAPING AS A RESULT OF SEAL FAILURE, MAKING IT
SUITABLE FOR USE IN CARPETED OR OTHER
DELICATE ENVIRONMENTS.

STANDARD FEATURES:
VMSE A M: (single-phase)
2 m power cable type H07 RN-F with removable
connector.
Control box with capacitor and Schuko plug.
VMSE A: (three-phase)
2 m power cable type H07 RN-F with removable
connector.

GUARANTEE 2 YEARS subject to our general


terms of sale.
CONSTRUCTION CHARACTERISTICS
OUTER CASE AND MOTOR SUPPORT: stainless
steel AISI 304 case with threaded ports ISO 228-1.
IMPELLERS AND DIFFUSERS: technopolymer.
VMSE

OPTIONS ON REQUEST
other voltages or frequency 60 Hz

CONSTRUCTION AND SAFETY STANDARDS


EN 60 335-1
EN 60034-1
IEC 335-1
IEC 34-1
CEI 61-150
CEI 2-3

DIMENSIONS
Vertical installation

Horizontal installation

DN2

SINGLE-PHASE CONTROL BOX


VMSE
h

VMSE

DN1

DN1

VMSE

DN2

46

VMSE B
in-line multi-stage pumps

VMSEB30

VMSEB25

H (m)

VMSEB20

VMSEB15
VMSEB10
VMSEB07M
VMSEB06M

Q
Q = Flow rate H = Total manometric head

TYPE
Single-phase
VMSE B 06M
VMSE B 07M
VMSE B 10M
VMSE B 15M
VMSE B 20M
VMSE B 25M
VMSE B 30M

Three-phase

VMSE B 10
VMSE B 15
VMSE B 20
VMSE B 25
VMSE B 30

Tolerance of the performance curves according to EN ISO 9906 App. A.

POWER
kW
HP
0.45
0.6
0.55
0.75
0.75
1
1.1
1.5
1.5
2
1.8
2.5
2.2
3

m3/h
l/min

H metres

0
0
30
40
50
60
75
90
105

1.2
20
27
37
48
56
72
85
101

1.8
30
26
36
46
54
69
83
98

2.4
40
25
34.5
44
52
66
79
94

3.0
50
24
32.5
41
50
64
76
90

3.6
60
22.5
30
38
48
60
73
86

4.2
70
20.5
28
35
46
57
68
80

4.8
80
18
25
32
43
53
64
75

5.4
90
15.5
21.5
28
39
48
58
67

6.0
100
13
18.5
24
36
43
52
60

6.6
110
10
14.5
19
31
38
44
52

7.2
120
7
10
14
24
32
38
44

DIMENSIONS AND WEIGHTS


TYPE
Single-phase

PORTS
Three-phase

DN

DIMENSIONS mm
N stages

kg
b

1~

3~

397

8.4

471

10.5

495

13.8

12.3

VMSE B 06M

VMSE B 07M

VMSE B 10M

VMSE B 10

VMSE B 15M

VMSE B 15

517

19.5

17.5

VMSE B 20M

VMSE B 20

547

20.6

18.9

VMSE B 25M

VMSE B 25

577

21.5

19.9

VMSE B 30M

VMSE B 30

652

27.2

23.2

11/4

135

153

81

200

66

47

RANGE OF PERFORMANCE
Maximum flow rate 120 l/min (7.2 m3/h)
Head up to 105 m

IMPELLERS AND DIFFUSERS: technopolymer.


DIAPHRAGMS: stainless steel AISI 304, complete with anti-wear rings.
MOTOR SHAFT:
stainless steelEN 10088-3 - 1.4104.
DOUBLE SEAL: mechanical seal silicon carbide-ceramic-NBR, with oil barrier chamber
and inner lip seal to protect the seal in the event
of dry running.
SCREWS: stainless steel AISI 304.
MOTOR: electric, asynchronous for continuous
duty.
VMSE B M: single-phase 220240V - 50 Hz with
thermal overload protector built into windings
below 1.5 kW. The 1.8 kW motor has an external
overload protector (with manual reset) incorporated into the control box.
VMSE B: three-phase 380415 V-50Hz.
INSULATION: class F.
PROTECTION: IP 68.

LIMITS OF USE
Manometric suction lift up to 7 m
Liquid temperature up to + 40C
INSTALLATION AND USE
They are recommended for pumping clean water
and liquids that are chemically non aggressive
to the materials from which the pump is made.
THEIR RELIABILITY AND QUIET running
MAKE THEM SUITABLE FOR domestic and
CIVIL APPLICATIONS AND, BECAUSE THE PUMP
IS FULLY SUBMERSIBLE WITH THE MOTOR
COOLED BY THE PUMPED LIQUID, IT CAN BE USED
SAFELY IN WET AREAS AND IN SPACES WITH
INSUFFICIENT VENTILATION. THE ENCLOSED
DESIGN ALSO ELIMINATES THE POSSIBILITY OF
WATER ESCAPING AS A RESULT OF SEAL FAILURE,
MAKING IT SUITABLE FOR USE IN CARPETED OR
OTHER DELICATE ENVIRONMENTS.

STANDARD FEATURES:
VMSE B M: (single-phase)
2 m power cable type H07 RN-F with removable
connector.
Control box with capacitor and Schuko plug.
VMSE B: (three-phase)
2 m power cable type H07 RN-F with removable
connector.

GUARANTEE 2 YEARS subject to our general


terms of sale.
CONSTRUCTION CHARACTERISTICS
OUTER CASE AND MOTOR SUPPORT: stainless steel AISI 304, case with threaded ports
ISO2281.
VMSE

OPTIONS ON REQUEST
other voltages or frequency 60 Hz

CONSTRUCTION AND SAFETY STANDARDS


EN 60 335-1
EN 60034-1
IEC 335-1
IEC 34-1
CEI 61-150
CEI 2-3

DIMENSIONS
Vertical installation

Horizontal installation

DN2

SINGLE-PHASE CONTROL BOX


VMSE
h

VMSE

DN1

DN1

VMSE

DN2

48

JS

JET self-priming pumps

JS08

JS07

H (m)

JS05

Q
Q = Flow rate H = Total manometric head

TYPE
Single-phase

Tolerance of the performance curves according to EN ISO 9906 App. A.

POWER
Three-phase

kW

HP

JS 05M

JS 05

0.37

0.50

JS 07M

JS 07

0.50

0.70

JS 08M

JS 08

0.60

0.85

m3/h
l/min
H metres

0.3

0.6

0.9

1.2

1.5

1.8

2.1

2.4

2.7

3.0

10

15

20

25

30

35

40

45

50

35

32

27

24

21

19

17

16

15

14

13

41

36

31

27

24

22

20

19

17

16

15

47

42

38

34

31

28.5

26

24

22

21.5

19

DIMENSIONS AND WEIGHTS


TYPE
Single-phase

PORTS
Three-phase

JS 05M

JS 05

JS 07M

JS 07

JS 08M

JS 08

DIMENSIONS mm

DN1

DN2

115

f
379
387/379

kg

h1

h2

h3

n1

1~

3~

9.3

9.1

171

127

33.5

160.5

160

124

24

10

10.0

9.5

10.2

10.1

49

RANGE OF PERFORMANCE
Flow rate up to 50 l/min (3 m3/h)
Head up to 47 m
LIMITS OF USE
Manometric suction lift up to 9 m
Liquid temperature up to + 40C
Environment temperature up to + 40C

INSTALLATION AND USE


They are recommended for pumping clean water
and liquids that are chemically non aggressive to
the materials from which the pump is made.
JS SELF-PRIMING PUMPS ARE DESIGNED FOR
SUCTION LIFTS AND CAN BE POSITIONED ABOVE
THE WATER SOURCE, INCLUDING APPLICATIONS
WITH AIR ENTRAINED IN THE WATER. DUE TO
THEIR RELIABILITY AND LOW MAINTENANCE,
THEY ARE RECOMMENDED FOR DOMESTIC USE,
INCLUDING WATER distribuTION (AS PART OF A
PRESSURE SET), GARDEN irrigaTION, eTc.
The pumps must be installed in enclosed places, or
at least protected against inclement weather.
GUARANTEE 2 YEARS subject to our general
terms of sale.

CONSTRUCTION CHARACTERISTICS
PUMP BODY: cast iron, with threaded ports
ISO228/1.
BODY BACK-PLATE:
stainless steel AISI 304.
EJECTOR ASSEMBLY:
technopolymer (approved for drinking water).
IMPELLER: brass.
MOTOR SHAFT:
stainless steelEN 10088-3 - 1.4104.
MECHANICAL SEAL:
ceramic - graphite - NBR.
ELECTRIC MOTOR: the pumps are close-coupled
to a carefully matched electric motor, quiet running, totally enclosed fan cooled, suitable for
continuous duty.
JS M: single-phase 230 V - 50 Hz with capacitor and
thermal overload protector.
JS: three-phase 230/400 V - 50 Hz.
INSULATION: class F.
PROTECTION: IP 44.

OPTIONS ON REQUEST
impeller in technopolymer (JS M..X - JS...X)
other voltages or frequency 60 Hz

CONSTRUCTION AND SAFETY STANDARDS


EN 60 335-1
EN 60034-1
IEC 335-1
IEC 34-1
CEI 61-150
CEI 2-3

DIMENSIONS
f
a

h1

h3

DN1

h2

DN2

n1

50

JS
JET self-priming pumps

JS15H

JS12H

JS10H
JS15L

H (m)

JS12L

JS10L

Q
Q = Flow rate H = Total manometric head

TYPE
Single-phase
JS 10HM
JS 12HM
JS 15HM
JS 10LM
JS 12LM
JS 15LM

Three-phase
JS 10H
JS 12H
JS 15H
JS 10L
JS 12L
JS 15L

Tolerance of the performance curves according to EN ISO 9906 App. A.

POWER
m3/h
l/min
kW
HP
0.75
1
0.90
1.25
1.1
1.5
H metres
0.75
1
0.90
1.25
1.1
1.5

0
0
56
64
70
46
50
55

0.3
5
51
58
66
42
48
52

0.6
10
47
54
62
40
46
50

0.9
15
44
51
58
38
44
48

1.2
20
41
48
54
37
42
46

1.5
25
39
45
51
35
41
45

1.8
30
36
43
48
33
39
43

2.4
40
32
38
43
30
36
40

2.7
45
30
36
41
29
35
39

3.0
50
28
34
38
27
33
37

3.6
60

4.2
70

4.8
80

25
31
35

23
29
33

21
27
30

DIMENSIONS AND WEIGHTS


TYPE
Single-phase

PORTS
Three-phase

DN1

DIMENSIONS mm

DN2

h1

h2

h3

kg
n

n1

1~

3~

JS 10HM

JS 10H

13.7

13.8

JS 12HM

JS 12H

15.0

14.0

JS 15HM

JS 15H

15.2

14.2

JS 10LM

JS 10L

JS 12LM
JS 15LM

113.5

402

201

147

35

182

180

142

22

10

13.7

13.8

JS 12L

15.0

14.0

JS 15L

15.2

14.2

51

RANGE OF PERFORMANCE
Flow rate up to 80 l/min (4.8 m3/h)
Head up to 70 m
LIMITS OF USE
Manometric suction lift up to 9 m
Liquid temperature up to + 40C
Environment temperature up to + 40C
CONSTRUCTION CHARACTERISTICS
PUMP BODY: cast iron, with threaded ports
ISO228/1.
BODY BACK-PLATE:
stainless steel AISI 304.
EJECTOR ASSEMBLY:
technopolymer (approved for drinking water).
IMPELLER: brass.
MOTOR SHAFT:
stainless steelEN 10088-3 - 1.4104.
MECHANICAL SEAL:
ceramic - graphite -NBR.
ELECTRIC MOTOR: the pumps are close-coupled
to a carefully matched electric motor, quiet running, totally enclosed fan cooled, suitable for
continuous duty.
JS M: single-phase 230 V - 50 Hz with capacitor and
thermal overload protector.
JS: three-phase 230/400 V - 50 Hz.
INSULATION: class F.
PROTECTION: IP 44.

INSTALLATION AND USE


They are recommended for pumping clean water
and liquids that are chemically non aggressive to
the materials from which the pump is made.
JS SELF-PRIMING PUMPS ARE DESIGNED FOR
SUCTION LIFTS AND CAN BE POSITIONED ABOVE
THE WATER SOURCE, INCLUDING APPLICATIONS
WITH AIR ENTRAINED IN THE WATER. DUE TO
THEIR RELIABILITY AND LOW MAINTENANCE,
THEY ARE RECOMMENDED FOR DOMESTIC USE,
INCLUDING WATER distribuTION (AS PART OF
A PRESSURE SET), GARDEN irrigaTION, eTc.
The pumps must be installed in enclosed places, or
at least protected against inclement weather.
GUARANTEE 2 YEARS subject to our general
terms of sale.

OPTIONS ON REQUEST
impeller in technopolymer (JS M...X - JS...X)
other voltages or frequency 60 Hz

CONSTRUCTION AND SAFETY STANDARDS


EN 60 335-1
EN 60034-1
IEC 335-1
IEC 34-1
CEI 61-150
CEI 2-3

DIMENSIONS
f

DN1

h1

h3

h2

DN2

n1

52

JSE
JET self-priming pumps

JSE 30H

JSE 30M

JSE 15H

JSE 20M

H (m)

JSE 20H

JSE 30L

JSE 15M

JSE 20L
JSE 15L

Q
Q = Flow rate H = Total manometric head

Single-phase
JSE 15HM
JSE 20HM

JSE 15MM
JSE 20MM

JSE 15LM
JSE 20LM

TYPE

Three-phase
JSE 15H
JSE 20H
JSE 30H
JSE 15M
JSE 20M
JSE 30M
JSE 15L
JSE 20L
JSE 30L

Tolerance of the performance curves according to EN ISO 9906 App. A.

POWER
kW
HP
1.1
1.5
1.5
2
2.2
3
1.1
1.5
1.5
2
2.2
3
1.1
1.5
1.5
2
2.2
3

m3/h
l/min

0
0
64
76
96
52
H metres 60
74
42
51
62

0.6
10
60
70
90
50
58
70
40
48
60

0.9
15
55
67
86
48
56
68
39
46
58

1.2
20
51
64
82
45
54
67
38
45
57

1.5
25
48
61
79
44
52
65
37
44
56

1.8
30
45
58
75
42
51
63
36
43
55

2.1
35
42.5
55.5
71.5
40
49
61
35
42
54

2.4
40
40
53
69
38
47
59
34
41
53

2.7
45
39
51
66
37
46
58
33
40
52

3.0
50
37
49
64
35
45
56
32
39
51

3.6
60
34
45
58
32
42
54
30
37
49

4.2
70
31
41
54
29
39
51
28
35
47

4.8
80

6.0
100

7.2
120

8.4
140

9.6
160

39
50
27
37
49
26
33
45

23
33
44
23
30
42

20
30
40
20
27
39

17
24
36.5

15
22
35

DIMENSIONS AND WEIGHTS


TYPE
Single-phase

PORTS
Three-phase

DN1

DIMENSIONS mm

DN2

h1

h2

h3

kg
n

n1

1~

3~
23.5

JSE 15HM

JSE 15H

25.4

JSE 20HM

JSE 20H

26.5

25.7

JSE 30H

26.8

JSE 15MM

JSE 15M

25.4

23.5

JSE 20MM

JSE 20M

JSE 30M

JSE 15LM
JSE 20LM

11/4

155

523

242

165

43

208

206

164

30

11

26.5

25.7

26.8

JSE 15L

25.4

23.5

JSE 20L

26.5

25.7

JSE 30L

26.8

53

RANGE OF PERFORMANCE
Flow rate up to 160 l/min (9.6 m3/h)
Head up to 96 m
LIMITS OF USE
Manometric suction lift up to 9 m
Liquid temperature up to + 40C
Environment temperature up to + 40C
INSTALLATION AND USE
They are recommended for pumping clean water
and liquids that are chemically non aggressive to
the materials from which the pump is made.
JSE SELF-PRIMING PUMPS ARE DESIGNED FOR
SUCTION LIFTS AND CAN BE POSITIONED ABOVE
THE WATER SOURCE, INCLUDING APPLICATIONS
WITH AIR ENTRAINED IN THE WATER. DUE TO
THEIR RELIABILITY AND LOW MAINTENANCE,
THEY ARE RECOMMENDED FOR DOMESTIC USE,
INCLUDING WATER distribuTION (AS PART OF
A PRESSURE SET), GARDEN irrigaTION, eTc.
The pumps must be installed in enclosed places, or
at least protected against inclement weather.
GUARANTEE 2 YEARS subject to our general
terms of sale.

CONSTRUCTION CHARACTERISTICS
PUMP BODY: cast iron, with threaded ports
ISO228/1.
BODY BACK-PLATE: cast iron.
EJECTOR ASSEMBLY:
technopolymer (approved for drinking water).
IMPELLER: brass.
MOTOR SHAFT:
stainless steelEN 10088-3 - 1.4104.
MECHANICAL SEAL:
ceramic - graphite - NBR.
ELECTRIC MOTOR: the pumps are close-coupled
to a carefully matched electric motor, quiet running, totally enclosed fan cooled, suitable for
continuous duty.
JSE M: single-phase 230 V - 50 Hz with capacitor
and thermal overload protector.
JSE: three-phase 230/400 V - 50 Hz.
INSULATION: class F.
PROTECTION: IP 44.

OPTIONS ON REQUEST
special mechanical seal
other voltages or frequency 60 Hz

CONSTRUCTION AND SAFETY STANDARDS


EN 60 335-1
EN 60034-1
IEC 335-1
IEC 34-1
CEI 61-150
CEI 2-3

DIMENSIONS
f

h3
h1
DN1

h2

DN2

n1

54
stainless steel pump body

JET-SS

JET self-priming pumps

JET 15HSS

JET 12HSS

JET 10HSS
JET 15LSS

H (m)

JET 08HSS
JET 12LSS

JET 07HSS
JET 05MSS

JET 10LSS

Q
Q = Flow rate H = Total manometric head

TYPE
Single-phase
JET 05MSS
JET 07MSS
JET 08MSS
JET 10HMSS
JET 12HMSS
JET 15HMSS
JET 10LMSS
JET 12LMSS
JET 15LMSS

Three-phase
JET 05SS
JET 07SS
JET 08SS
JET 10HSS
JET 12HSS
JET 15HSS
JET 10LSS
JET 12LSS
JET 15LSS

Tolerance of the performance curves according to EN ISO 9906 App. A.

POWER
m3/h
l/min
kW
HP
0.37
0.50
0.50
0.70
0.60
0.85
0.75
1
0.90
1.25 H metres
1.1
1.5
0.75
1
0.90
1.25
1.1
1.5

0
0
35
41
47
56
64
72
46
50
55

0.3
5
32
36
42
50
58
67
44
48
53

0.6
10
27
31
38
45
53
61
41
45
50

0.9
15
24
27
34
41
48
56
39
43
48

1.2
20
21
24
31
37
44
51
37
41
46

1.5
25
19
22
28.5
33
40
47
35
39
43

1.8
30
17
20
26
30
36
43
32
37
41

2.1
35
16
19
24
27
33
40
30
36
39

2.4
40
15
17
22
25
31
37
28
34
37

3.0
50
13
15
19
22
26
32
25
30
34

3.6
60

4.2
70

4.8
80

22
27
31

21
25
29

19
23
27

DIMENSIONS AND WEIGHTS


TYPE
Single-phase

PORTS
Three-phase

JET 05MSS

JET 05SS

JET 07MSS

JET 07SS

JET 08MSS

JET 08SS

DIMENSIONS mm

DN1

DN2

90

f
345

kg

h1

h2

n1

174

122

52

160

120

95

353/345

JET 10HMSS-LMSS JET 10HSS-LSS


JET 12HMSS-LMSS JET 12HSS-LSS
JET 15HMSS-LMSS JET 15HSS-LSS

11/4

117

406

206

145

55

184

135

110

10

1~

3~

5.6

5.8

5.7

6.0

6.9

6.5

9.4

9.6

10.5

9.6

10.8

10.4

55

RANGE OF PERFORMANCE
Flow rate up to 80 l/min (4.8 m3/h)
Head up to 72 m
LIMITS OF USE
Manometric suction lift up to 9 m
Liquid temperature up to + 40C
Environment temperature up to + 40C
threaded ports ISO228/1.
BODY BACK-PLATE:
stainless steel AISI 304.
EJECTOR ASSEMBLY:
technopolymer (approved for drinking water).
IMPELLER:
technopolymer (for drinking water).
MOTOR SHAFT:
stainless steelEN 10088-3 - 1.4104
MECHANICAL SEAL:
ceramic - graphite - NBR.
ELECTRIC MOTOR: the pumps are close-coupled
to a carefully matched electric motor, quiet running, totally enclosed fan cooled, suitable for
continuous duty.
JET MSS: single-phase 230 V - 50 Hz with capacitor
and thermal overload protector.
JET SS: three-phase 230/400 V - 50 Hz.
INSULATION: class F.
PROTECTION: IP 44.

INSTALLATION AND USE


They are recommended for pumping clean water
and liquids that are chemically non aggressive to
the materials from which the pump is made.
JET-SS SELF-PRIMING PUMPS ARE DESIGNED
FOR SUCTION LIFTS AND CAN BE POSITIONED
ABOVE THE WATER SOURCE, INCLUDING
APPLICATIONS WITH AIR ENTRAINED IN THE
WATER. DUE TO THEIR RELIABILITY AND LOW
MAINTENANCE, THEY ARE RECOMMENDED
FOR DOMESTIC USE, INCLUDING WATER
distribuTION (AS PART OF A PRESSURE SET),
GARDEN irrigaTION, eTc.
The pumps must be installed in enclosed places, or
at least protected against inclement weather.
GUARANTEE 2 YEARS subject to our general
terms of sale.
CONSTRUCTION CHARACTERISTICS
PUMP BODY: stainless steel AISI 304, with

OPTIONS ON REQUEST
other voltages or frequency 60 Hz

CONSTRUCTION AND SAFETY STANDARDS


EN 60 335-1
EN 60034-1
IEC 335-1
IEC 34-1
CEI 61-150
CEI 2-3

DIMENSIONS
f

DN2

h1

h2
DN1

n1

56

K
standardised centrifugal pumps to EN 733 - DIN 24255

K50/250
K40/250

K50/200
K65/200

K32/200
K40/200

H (m)

H (feet)

K32/200H

K50/160

K65/160
K80/160

20

K32/160

K40/160
K65/125
K100/60

K50/125

57

RANGE OF PERFORMANCE
Flow rate up to 6000 l/min (360 m3/h)
Head up to 95 m
LIMITS OF USE
Manometric suction lift up to 7 m
Liquid temperature from -10C to + 90C
Environment temperature from -10C
to + 40C
Max. pressure in the pump body 10 bar
(PN10)

INSTALLATION AND USE


They are recommended for pumping clean water
and liquids that are chemically non aggressive to the
materials from which the pump is made.
THIS serieS IS SUITABLE FOR SUPPLYING AND
MOVING WATER, IN COOLING, HEATING, CIRCULATING AND CONDITIONING SYSTEMS, FOR
FIRE FIGHTING, IRRIGATION, industrial ANd
agricULTURAL APPLICATIONS.
Manifacture in accordance with dimensional
standards EN 733 - DIN 24255 ensures models
are fully interchangeable. The design allows the
pump body to be removed without disconnecting
it from the pipes (back pull out).
The pumps must be installed in enclosed places, or
at least protected against inclement weather.
GUARANTEE 2 YEARS subject to our general
terms of sale.

CONSTRUCTION AND SAFETY STANDARDS


EN 60034-1
IEC 34-1
CEI 2-3

CONSTRUCTION CHARACTERISTICS
PUMP BODY: cast iron, complies with dimensional standards EN 733 - DIN 24255 and UNI 7467-NF
E-44-111, with flanged suction and delivery ports
complete with threaded steel counterflanges.
BODY BACK-PLATE: cast iron.
IMPELLER: brass for models K32/160, K32/200,
K40/160, K40/200, K50/125 and K50/160.
IMPELLER: cast iron for models K40/250,
K50/200, K50/250, K65/125, K65/160, K65/200,
K80/160, K100/160
MOTOR SHAFT:
stainless steelEN 10088-3 - 1.4104.
MECHANICAL SEAL:
ceramic - graphite - NBR.
ELECTRIC MOTOR: the pumps are close-coupled
to a carefully matched electric motor, asynchronous type with high efficiency (class EFF1
for powers from 4 to 22 kW), quiet running,
totally enclosed fan cooled, suitable for continuous
duty.

K M: single-phase 230 V - 50 Hz with capacitor and


thermal overload protector (up to 1.5 kW).
K: three-phase 230/400 V - 50 Hz up to 4 kW.
400/690 V - 50 Hz from 5.5 to 22 kW.
INSULATION: classe K.
PROTECTION: IP 44.
OPTIONS ON REQUEST
pump shaft in stainless steel
EN 10088-3 - 1.4401 (AISI 316)
special mechanical seal
other voltages or frequency 60 Hz
protection IP 55
for liquids with higher or lower temperatures
for environments with higher or lower temperatures

58

K 32/160
DN1= 50
DN2= 32

K32/160A

K32/160B
H (feet)

H (m)

(m)

NPSH (m)

NPSH (feet)

K32/160C

K32/160A

P2 (HP)

P2 (kW)

K32/160B
K32/160C

Q = Flow rate H = Total manometric head

TYPE
Single-phase

Tolerance of the performance curves according to EN ISO 9906 App. A.

POWER
kW

HP

K 32/160CM

K 32/160C

Three-phase

1.5

K 32/160BM

K 32/160B

2.2

K 32/160AM

K 32/160A

m3/h
l/min
H metres

12

15

18

21

24

27

400

450

100

150

200

250

300

350

25

24

23

21

19

16

13

31

30

29

28

26

23.5

20

16

38

37

36

34

32

30

27.5

24

20

59

K 32/200
DN1= 50
DN2= 32

K32/200A

H (m)

H (feet)

K32/200B

(m)

NPSH (m)

NPSH (feet)

K32/200C

K32/200A
K32/200B
P2 (HP)

P2 (kW)

K32/200C

Q = Flow rate H = Total manometric head

TYPE
Three-phase

POWER
kW

HP

K 32/200C

5.5

K 32/200B

5.5

7.5

K 32/200A

7.5

10

m3/h
l/min
H metres

Tolerance of the performance curves according to EN ISO 9906 App. A.

12

15

18

21

24

27

30

100

150

200

250

300

350

400

450

500

46

44

43

41.5

40

38

36

34

31.5

54

52

50.5

49

47

45

43

41

38.5

36

60

57

56.5

56

55

53

52

50

47

44

60

K 32/200H
DN1= 50
DN2= 32

K32/200AH

H (feet)

(m)

NPSH (m)

NPSH (feet)

H (m)

K32/200BH

K32/200AH

P2 (HP)

P2 (kW)

K32/200BH

Q = Flow rate H = Total manometric head

TYPE
Single-phase

Tolerance of the performance curves according to EN ISO 9906 App. A.

POWER
Three-phase

kW

HP

K 32/200BHM

K 32/200BH

K 32/200AH

5.5

m3/h
l/min
H metres

12

15

18

100

150

200

250

300

49

45

42

39

34

28

59

55

52

49

44

38

61

K 40/160
DN1= 65
DN2=40
K40/160A

H (feet)
NPSH (feet)

K40/160C

(m)

NPSH (m)

H (m)

K40/160B

K40/160A

P2 (HP)

P2 (kW)

K40/160B
K40/160C

Q = Flow rate H = Total manometric head

TYPE
Single-phase

Tolerance of the performance curves according to EN ISO 9906 App. A.

POWER
Three-phase

kW

HP

K 40/160CM

K 40/160C

2.2

K 40/160BM

K 40/160B

K 40/160A

5.5

m3/h
l/min
H metres

12

15

18

24

30

36

42

100

150

200

250

300

400

500

600

700

27

27

26.5

26

25.5

25

22.5

19

14

32

32

31.5

31

30.5

30

27.5

24

20

38

38

37.8

37

36.5

36

33.5

30

26

20

62

K 40/200
DN1= 65
DN2= 40

K40/200A

(m)

NPSH (m)

NPSH (feet)

H (m)

H (feet)

K40/200B

K40/200A

P2 (HP)

P2 (kW)

K40/200B

Q = Flow rate H = Total manometric head

TYPE
Three-phase

POWER
kW

HP

K 40/200B

5.5

7.5

K 40/200A

7.5

10

m3/h
l/min
H metres

Tolerance of the performance curves according to EN ISO 9906 App. A.

12

15

18

24

30

36

42

100

150

200

250

300

400

500

600

700

48

47

46.5

46

45.5

44.5

42

38

34

28

56

55

55

55

54.5

54

52.5

49.5

46

41

63

K 40/250
DN1= 65
DN2= 40

H (feet)

H (m)

K40/250A

K40/250B

(m)

NPSH (m)

NPSH (feet)

K40/250C

K40/250A

K40/250B
P2 (HP)

P2 (kW)

K40/250C

Q = Flow rate H = Total manometric head

TYPE
Three-phase

POWER
kW

HP

K 40/250C

9.2

12.5

K 40/250B

11

15

K 40/250A

15

20

m3/h
l/min
H metres

Tolerance of the performance curves according to EN ISO 9906 App. A.

12

15

18

24

30

36

42

100

150

200

250

300

400

500

600

700

64

64

63.5

63

62.5

62

60

56.5

52.5

47

71

71

70.5

70

69.5

69

67

64

60

55

88

88

87.5

87

86.5

86

84

81

77

72

64

K 50/125
DN1= 65
DN2= 50
K50/125A

H (feet)
NPSH (feet)

K50/125C

(m)

NPSH (m)

H (m)

K50/125B

K50/125A

K50/125C

P2 (HP)

P2 (kW)

K50/125B

Q = Flow rate H = Total manometric head

TYPE
Single-phase

Tolerance of the performance curves according to EN ISO 9906 App. A.

POWER
Three-phase

kW

HP

K 50/125CM

K 50/125C

2.2

K 50/125BM

K 50/125B

K 50/125A

5.5

m3/h
l/min
H metres

18

24

30

36

42

48

54

60

66

72

300

400

500

600

700

800

900

1000

1100

1200
6

18.5

17.5

17

16.5

15.5

14.8

13.5

12

10.5

8.2

21.5

20.7

20

19.5

18.8

17.8

16.5

15

13.5

11.2

24.5

23.5

23

22.5

21.8

20.8

19.5

18.3

16.8

15

13

65

K 50/160
DN1= 65
DN2= 50

K50/160A

H (feet)

H (m)

K50/160B

(m)

NPSH (m)

NPSH (feet)

K50/160C

K50/160A

P2 (HP)

P2 (kW)

K50/160B

K50/160C

Q = Flow rate H = Total manometric head

TYPE
Three-phase

POWER
kW

HP

K 50/160C

5.5

K 50/160B

5.5

7.5

K 50/160A

7.5

10

m3/h
l/min
H metres

Tolerance of the performance curves according to EN ISO 9906 App. A.

18

24

30

36

42

48

54

60

66

300

400

500

600

700

800

900

1000

1100

27

27

26.5

25

24.5

23

20

18.5

16

33

32

31.7

31

30

29

27

26

24

21

38

37

36.8

36.5

36

34

33

32

30

27

66

K 50/200
DN1= 65
DN2= 50

K50/200AR

H (feet)

H (m)

K50/200A

K50/200B

(m)

NPSH (m)

NPSH (feet)

K50/200C

K50/200AR
K50/200A

P2 (HP)

P2 (kW)

K50/200B
K50/200C

Q = Flow rate H = Total manometric head

TYPE
Three-phase

POWER
kW

HP

m3/h
l/min

Tolerance of the performance curves according to EN ISO 9906 App. A.

24

36

48

60

72

84

96

102

108

400

600

800

1000

1200

1400

1600

1700

1800

K 50/200C

11

15

44

44

44

42

39

36

33

30

K 50/200B

15

20

52

52

52

50

47

44

40

38

K 50/200A

18.5

25

K 50/200AR

22

30

H metres

61

61

60.5

60

57

54

50

48

45

69

69

68.5

68

65

62

58

56

53

67

K 50/250
K50/250AR

K50/250A

H (m)

H (feet)

K50/250B

K50/250C
K50/250D

(m)

NPSH (m)

NPSH (feet)

DN1= 65
DN2= 50

K50/250AR
K50/250A

P2 (HP)

P2 (kW)

K50/250B

K50/250C
K50/250D

Q = Flow rate H = Total manometric head

TYPE
Three-phase

POWER

m3/h
l/min

Tolerance of the performance curves according to EN ISO 9906 App. A.

18

24

30

36

42

48

54

60

300

400

500

600

700

800

900

1000

49

47

44

41

37

32

58

57

54

51

47

42

kW

HP

K 50/250D

9.2

12.5

51

51

K 50/250C

11

15

59

59

K 50/250B

15

20

72

72

71

70

69

67

65

62

59

K 50/250A

18.5

25

H metres

85

85

84

83

82

80

78

76

73

K 50/250AR

22

30

95

95

94

93

92

90

88

86

83

68

K 65/125
DN1= 80
DN2= 65

K65/125A

H (m)

H (feet)

K65/125B

(m)

NPSH (m)

NPSH (feet)

K65/125C

K65/125A

P2 (HP)

P2 (kW)

K65/125B
K65/125C

Q = Flow rate H = Total manometric head

TYPE
Three-phase

POWER
kW

HP

K 65/125C

5.5

K 65/125B

5.5

7.5

K 65/125A

7.5

10

Tolerance of the performance curves according to EN ISO 9906 App. A.

m3/h
l/min

36

48

60

72

84

96

108

120

132

600

800

1000

1200

1400

1600

1800

2000

2200

16

16

16

15.5

14.5

13.5

12.5

11

H metres

18

18

18

18

17

16.5

15.5

14.5

13

23

23

23

23

22.5

22.5

22

21

19.5

18

69

K 65/160
DN1= 80
DN2= 65
K65/160A

H (feet)

H (m)

K65/160B

(m)

NPSH (m)

NPSH (feet)

K65/160C

K65/160A

K65/160B

P2 (HP)

P2 (kW)

K65/160C

Q = Flow rate H = Total manometric head

TYPE
Three-phase

POWER
kW

HP

K 65/160C

9.2

12.5

K 65/160B

11

15

K 65/160A

15

20

m3/h
l/min
H metres

Tolerance of the performance curves according to EN ISO 9906 App. A.

36

48

60

72

84

96

108

120

132

144

600

800

1000

1200

1400

1600

1800

2000

2200

2400

32

32

32

32

32

30

29

27

25

22

37

36.5

36.5

36

35.5

34

33

31

29

26

23

41

40.5

40.5

40

39.5

39

37.5

36

34

31

28

70

K 65/200
DN1= 80
DN2= 65

K65/200AR

H (m)

H (feet)

K65/200A

(m)

NPSH (m)

NPSH (feet)

K65/200B

K65/200AR
K65/200A

P2 (HP)

P2 (kW)

K65/200B

Q = Flow rate H = Total manometric head

TYPE
Three-phase

POWER
kW

HP

K 65/200B

15

20

K 65/200A

18.5

25

K 65/200AR

22

30

m3/h
l/min
H metres

Tolerance of the performance curves according to EN ISO 9906 App. A.

24

36

48

60

72

84

96

108

120

126

400

600

800

1000

1200

1400

1600

1800

2000

2100

45

45

45

45

44

42.5

41

38.5

35.5

51

51

51

51

50

49

47

44.5

41.5

40

57

57

57

57

56

55

53

50.5

47.5

46

71

K 80/160
DN1=100
DN2= 80

K80/160A
K80/160B

H (feet)

H (m)

K80/160C

(m)

NPSH (m)

NPSH (feet)

K80/160D

K80/160A
K80/160B

P2 (HP)

P2 (kW)

K80/160C
K80/160D

Q = Flow rate H = Total manometric head

TYPE
Three-phase

POWER
kW

HP

m3/h
l/min

Tolerance of the performance curves according to EN ISO 9906 App. A.

30

60

90

120

150

180

210

240

500

1000

1500

2000

2500

3000

3500

4000
10

K 80/160D

11

15

25

25

25

24.5

23.5

21

18

14.5

K 80/160C

15

20

30

30

30

29.5

28.5

26

23

19.5

15

K 80/160B

18.5

25

35

35

35

34.5

33.5

31

28

24.5

20

K 80/160A

22

30

40

40

40

39.5

38.5

36

33

29.5

25

H metres

72

K 100/160
DN1= 125
DN2= 100

K100/160A
K100/160B

(m)

NPSH (m)

NPSH (feet)

H (m)

H (feet)

K100/160C

K100/160A
K100/160B
P2 (HP)

P2 (kW)

K100/160C

Q = Flow rate H = Total manometric head

TYPE
Three-phase

POWER
kW

HP

K 100/160C

15

20

K 100/160B

18.5

25

K 100/160A

22

30

m3/h
l/min
H metres

Tolerance of the performance curves according to EN ISO 9906 App. A.

60

120

180

240

270

300

330

360

1000

2000

3000

4000

4500

5000

5500

6000

28

28

25.5

22

17.5

15

12

32

32

30

27

22.5

19.5

17

13

35

35

34

31

27

24.5

22

18

15

73
DIMENSIONS AND WEIGHTS
n

h1

DN1

h2

DN2

n1
n2

w1 w2

Single-phase
K32/160CM
K32/160BM
K32/160AM

K 32/200BHM

K 40/160CM
K 40/160BM

K 50/125CM
K 50/125BM

DN FLANGES
mm
32
40
50
65
80
100
125

TYPE

Three-phase
K32/160C
K32/160B
K32/160A
K 32/200C
K 32/200B
K 32/200A
K 32/200BH
K 32/200AH
K 40/160C
K 40/160B
K 40/160A
K 40/200B
K 40/200A
K 40/250C
K 40/250B
K 40/250A
K 50/125C
K 50/125B
K 50/125A
K 50/160C
K 50/160B
K 50/160A
K 50/200C
K 50/200B
K 50/200A
K 50/200AR
K 50/250D
K 50/250C
K 50/250B
K 50/250A
K 50/250AR
K 65/125C
K 65/125B
K 65/125A
K 65/160C
K 65/160B
K 65/160A
K 65/200B
K 65/200A
K 65/200AR
K 80/160D
K 80/160C
K 80/160B
K 80/160A
K 100/160C
K 100/160B
K 100/160A

t
mm
140
150
165
185
200
220
250

PORTS
DN1
DN2

50

f
412
431/412
465/431
469

32

DIMENSIONS mm
n
n1

h1

h2

292

132

160

242

340

160

180

270

431/412
465/431
465

292

132

160

240

535

340

160

180

405

180

292

132

515

80

n2

190

240

275

212

265

225

328

250

320

160

242

190

240

180

269

469

65

40

606
701
450/431
484/450
484
489
535
65

340

616

50

711
100

160
360

200

316

225

337

180

291

200

300

212

265

250

320

212

280

250

320

280

360

w1

w2

35

35

47.5

47.5

35

35

47.5

47.5

60

60

14

743
606
701
733
511
557

80

621

65

716

405

180

340
160
360

719
751
652
100

80

u
mm
100
110
125
145
160
180
210

405

180

225

747
125

125

340

779
758

100

790

HOLES

330

480

200

280

362

kg*

3~
38.4
39.2
42.6
52.1
57.0
63.0
48.5
52.8
41.2
43.9
50.5
61.4
65.9
108.0
115.0
132.0
41.4
44.2
50.5
55.5
60.5
65.0
105.3
121.7
134.2
145.7
111.0
118.0
135.0
148.0
159.5
62.0
67.7
72.0
100.0
107.0
123.0
128.0
141.5
153.0
112.5
129.5
142.5
154.0
141.2
153.7
165.2

(*weight includes counterflanges)

DN

DN

u
t

u
t

(mm)

4
18
8

18

1~
39.2
42.6
52.8
43.9
50.5
44.2
50.5
-

74

UTILITY
portable self-priming pumps
RANGE OF PERFORMANCE
Flow rate up to 50 l/min (3 m3/h)
Head up to 47 m
LIMITS OF USE
Manometric suction lift up to 9 m
Liquid temperature up to + 40C
Environment temperature up to + 40C

INSTALLATION AND USE


portable self-priming pumps CAPable OF
CLEARING ENTRAINED AIR FROM THE suction
pipe.
recommended foR gardening, vegetable
gardens, washing AND hobby applications they are suitable for USE WITH ANY
LIQUIDS COMPATIBLE WITH THE MATERIALS OF
CONSTRUCTION.
GUARANTEE 2 YEARS subject to our general
terms of sale.
CONSTRUCTION CHARACTERISTICS
PUMP BODY UTILITY 05M,07M,08M:
cast iron;
PUMP BODY UTILITY 05MSS, 07MSS, 08MSS:
stainless steel AISI 304.
IMPELLER: technopolymer, centrifugal type.
MOTOR SHAFT:
stainless steelEN 10088-3 - 1.4104.
MECHANICAL SEAL:
ceramic - graphite - NBR.
ELECTRIC MOTOR: induction motor, for continuous duty.
Single-phase: 230 V - 50 Hz with capacitor and
thermal overload protector.
INSULATION: class F.
PROTECTION: IP 44.
STANDARD FEATURES:
Carrying handle.
Hosetails 20 mm.
1.5 m power cable with Schuko plug.

CONSTRUCTION AND SAFETY STANDARDS


EN 60 335-1
EN 60034-1
IEC 335-1
IEC 34-1
CEI 61-150
CEI 2-3

75

UTILITY/08M

UTILITY/07M

H (m)

UTILITY/05M

Q
Q = Flow rate H = Total manometric head

TYPE
Single-phase
UTILITY/05M
UTILITY/07M
UTILITY/08M

POWER
m3/h
l/min
kW
HP
0.37
0.50
0.50
0.70 H metres
0.60
0.85

Tolerance of the performance curves according to EN ISO 9906 App. A.

0
0
35
41
47

0.3
5
32
36
42

0.6
10
27
31
38

0.9
15
24
27
34

1.2
20
21
24
31

1.5
25
19
22
28.5

1.8
30
17
20
26

2.1
35
16
19
24

2.4
40
15
17
22

2.7
45
14
16
21.5

3.0
50
13
15
19

DIMENSIONS AND WEIGHTS

hh

h1

DN1

DN2

TYPE
Single-phase

f1
nn

PORTS

DIMENSIONS mm

DN1

DN2

20

20

UTILITY/05M
UTILITY/07M
UTILITY/08M

f1

439

379

447

387

kg
h

h1

260

255

230

10.0
10.7
10.9

76

UTILITY/08MSS

UTILITY/07MSS

H (m)

UTILITY/05MSS

Q
Q = Flow rate H = Total manometric head

TYPE
Single-phase
UTILITY/05MSS
UTILITY/07MSS
UTILITY/08MSS

POWER
m3/h
l/min
kW
HP
0.37
0.50
0.50
0.70 H metres
0.60
0.85

Tolerance of the performance curves according to EN ISO 9906 App. A.

0
0
35
41
47

0.3
5
32
36
42

0.6
10
27
31
38

0.9
15
24
27
34

1.2
20
21
24
31

1.5
25
19
22
28.5

1.8
30
17
20
26

2.1
35
16
19
24

2.4
40
15
17
22

2.7
45
14
16
21.5

3.0
50
13
15
19

DIMENSIONS AND WEIGHTS

h1

DN1

DN2

f1

f
TYPE
Single-phase

PORTS

DIMENSIONS mm

DN1

DN2

20

20

UTILITY/05MSS
UTILITY/07MSS
UTILITY/08MSS

f1

405

345

413

353

kg
h

h1

270

260

198

7.9
8.0
9.2

77

PC PUMP
pumps with electronic controller

Domestic pumps with a pressure sensing electronic controller for automatic operation; the pump operates as required as a tap is opened or closed.
The controller also provides protection for the pump against dry running.

DIMENSIONS
POWER
kW
0.37
0.50
0.60
0.75
1.1
0.75
0.75
1.1
1.1
0.75
1.1
1.1
0.37
0.45
0.60
0.60
0.75
0.37
0.50
0.60
0.75
0.90
1.1
0.75
0.90
1.1
1.1
1.1
1.1

HP
0.50
0.70
0.85
1
1.5
1
1
1.5
1.5
1
1.5
1.5
0.50
0.60
0.85
0.85
1
0.50
0.70
0.85
1
1.25
1.5
1
1.25
1.5
1.5
1.5
1.5

Peso 1.1 kg

Typical installation

COMPONENTS
- Single-phase electropump 230V - 50Hz
- PRESSURE CONTROL
- 1.5 metre cable with Schuko plug
*For correct operation of the PRESSURE CONTROL device, the
height of the column of water must not exceed 15 metres

*maximum height approx. 15 metres

TYPE
Single-phase
PC/IP 500M
PC/IP 700M
PC/IP 800M
PC/IP 1000M
PC/IP 1500M
PC/IC 100M
PC/IC 100MH
PC/IC 150M
PC/IC 150LM
PC/ICB 100NM
PC/ICB 150HM
PC/ICB 150MM
PC/MSG 05M
PC/MSG 07M
PC/MSG 08M
PC/MSG 08LM
PC/MSG 10M
PC/JS 05M
PC/JS 07M
PC/JS 08M
PC/JS 10HM
PC/JS 12HM
PC/JS 15HM
PC/JS 10LM
PC/JS 12LM
PC/JS 15LM
PC/JSE 15HM
PC/JSE 15MM
PC/JSE 15LM

78

BOOSTER SETS-24SP
Small pressure sets with 24 litre spherical vessel, for automatic
operation. Suitable for the supply of pressurised water in houses or
in holiday homes.

PERFORMANCE AND DIMENSIONS

Single-phase
24SP/IP 500M
24SP/IP 700M
24SP/IP 800M
24SP/IP 1000M
24SP/IP 1500M
24SP/IC 75M
24SP/IC 100MH
24SP/IC 150M
24SP/IC 150LM
24SP/ICB 100NM
24SP/ICB 150HM
24SP/ICB 150MM
24SP/MSG 07M
24SP/MSG 08M
24SP/MSG 08LM
24SP/MSG 10M
24SP/MS 07M
24SP/MS 08M
24SP/MS 08LM
24SP/JS 05M
24SP/JS 07M
24SP/JS 08M
24SP/JS 10HM
24SP/JS 12HM
24SP/JS 15HM
24SP/JS 10LM
24SP/JS 12LM
24SP/JS 15LM
24SP/JSE 15HM
24SP/JSE 15MM
24SP/JSE 15LM
24SP/JET 05MSS
24SP/JET 07MSS
24SP/JET 08MSS
24SP/JET 10 HMSS
24SP/JET 12HMSS
24SP/JET 15HMSS
24SP/JET 10LMSS
24SP/JET 12LMSS
24SP/JET 15LMSS

suc. deliv.
1
1
1
1
1
1
1
1
1
1
1
1
1
1
11/4 1
11/4 1
11/4 1
11/4 1
11/2 1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
11/4 1
11/4 1
11/4 1
1
1
1
1
1
1
11/4 1
11/4 1
11/4 1
11/4 1
11/4 1
11/4 1

POWER
kW
0.37
0.50
0.60
0.75
1.1
0.55
0.75
1.1
1.1
0.75
1.1
1.1
0.45
0.60
0.60
0.75
0.45
0.60
0.60
0.37
0.50
0.60
0.75
0.90
1.1
0.75
0.90
1.1
1.1
1.1
1.1
0.37
0.50
0.60
0.75
0.90
1.1
0.75
0.90
1.1

HP
0.50
0.70
0.85
1
1.5
0.75
1
1.5
1.5
1
1.5
1.5
0.60
0.85
0.85
1
0.60
0.85
0.85
0.50
0.70
0.85
1
1.25
1.5
1
1.25
1.5
1.5
1.5
1.5
0.50
0.70
0.85
1
1.25
1.5
1
1.25
1.5

FLOW
SETTING
RATE (recommended)
(1)
(2)
l/min
min
max
32
1.4
2.8
40
1.5
3.0
50
1.8
3.2
50
2.2
3.6
50
3.5
4.5
80
1.4
2.8
90
1.8
3.2
120
2.2
3.5
150
2.0
3.5
100
1.4
2.8
100
2.2
3.6
140
2.2
3.6
60
1.4
2.8
60
2.2
3.6
100
1.4
2.8
100
2
3.5
60
1.4
2.8
60
2.2
3.6
100
1.4
2.8
45
1.2
2.6
50
1.4
2.8
50
1.8
3.2
50
2.0
3.2
50
2.5
4.0
50
3.0
4.5
80
1.4
2.8
80
2.0
3.5
80
2.5
4.0
70
3.0
4.5
120
2.0
3.5
160
1.4
2.8
50
1.2
2.6
50
1.4
2.8
50
1.8
3.2
50
2.0
3.4
50
2.4
3.8
50
3.0
4.0
80
1.4
2.8
80
2.0
3.5
80
2.5
4.0

DIMENSIONS
mm
l
381
389
409
409
447
434
434
470
470
437
462
462
401
408
408
423
435
443
423
434
434
441
460
460
460
460
460
460
522
522
522
435
435
443
460
460
460
460
460
460

a
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360
360

h
513
518
531
531
549
617
617
635
635
576
599
599
550
550
550
550
548
548
548
536
536
536
555
555
555
555
555
555
583
583
583
548
548
548
579
579
579
579
579
579

PORTS

DN2
DN1

TYPE

BOOSTER SETS-24 SP COMPONENTS


- Single-phase pump 230 V - 50 Hz
- 24 litre spherical vessel
- Pressure switch SQUARE-D
- Pressure gauge
- 3 or 5-way brass connector
- 1.5 metre cable with Schuko plug

(1) Maximum flow rate with the minimum recommended


pressure switch settings
(2) Pressure switch recommended rate
N.B. The pre-charge of air in diaphragm tanks must be set to a value 0.2 bar
lower than the minimum setting of the pressure switch.

79

BOOSTER SETS-24CY
Small pressure sets with 20 litre cylindrical vessel, for automatic operation. Suitable for the supply of pressurised water in houses or in holiday
homes.

PERFORMANCE AND DIMENSIONS

Single-phase
24CY/IP 500M
24CY/IP 700M
24CY/IP 800M
24CY/IP 1000M
24CTY/IP 1500M
24CY/IC 75M
24CY/IC 100MH
24CY/IC 150M
24CY/IC 150LM
24CY/ICB 100NM
24CY/ICB 150HM
24CY/ICB 150MM
24CY/MSG 07M
24CY/MSG 08M
24CY/MSG 08LM
24CY/MSG 10M
24CY/MS 07M
24CY/MS 08M
24CY/MS 08LM
24CY/JS 05M
24CY/JS 07M
24CY/JS 08M
24CY/JS 10HM
24CY/JS 12HM
24CY/JS 15HM
24CY/JS 10LM
24CY/JS 12LM
24CY/JS 15LM
24CY/JSE 15HM
24CY/JSE 15MM
24CY/JSE 15LM
24CY/JET 05MSS
24CY/JET 07MSS
24CY/JET 08MSS
24CY/JET 10 HMSS
24CY/JET 12HMSS
24CY/JET 15HMSS
24CY/JET 10LMSS
24CY/JET 12LMSS
24CY/JET 15LMSS

suc. deliv.
1
1
1
1
1
1
1
1
1
1
1
1
1
1
11/4 1
11/4 1
11/4 1
11/4 1
11/2 1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
11/4 1
11/4 1
11/4 1
1
1
1
1
1
1
11/4 1
11/4 1
11/4 1
11/4 1
11/4 1
11/4 1

POWER
kW
0.37
0.50
0.60
0.75
1.1
0.55
0.75
1.1
1.1
0.75
1.1
1.1
0.45
0.60
0.60
0.75
0.45
0.60
0.60
0.37
0.50
0.60
0.75
0.90
1.1
0.75
0.90
1.1
1.1
1.1
1.1
0.37
0.50
0.60
0.75
0.90
1.1
0.75
0.90
1.1

HP
0.50
0.70
0.85
1
1.5
0.75
1
1.5
1.5
1
1.5
1.5
0.60
0.85
0.85
1
0.60
0.85
0.85
0.50
0.70
0.85
1
1.25
1.5
1
1.25
1.5
1.5
1.5
1.5
0.50
0.70
0.85
1
1.25
1.5
1
1.25
1.5

FLOW
SETTING
RATE (recommended)
(1)
(2)
l/min
min
max
32
1.4
2.8
40
1.5
3.0
50
1.8
3.2
50
2.2
3.6
50
3.5
4.5
80
1.4
2.8
90
1.8
3.2
120
2.2
3.5
150
2.0
3.5
100
1.4
2.8
100
2.2
3.6
140
2.2
3.6
60
1.4
2.8
60
2.2
3.6
100
1.4
2.8
100
2
3.5
60
1.4
2.8
60
2.2
3.6
100
1.4
2.8
45
1.2
2.6
50
1.4
2.8
50
1.8
3.2
50
2.0
3.2
50
2.5
4.0
50
3.0
4.5
80
1.4
2.8
80
2.0
3.5
80
2.5
4.0
70
3.0
4.5
120
2.0
3.5
160
1.4
2.8
50
1.2
2.6
50
1.4
2.8
50
1.8
3.2
50
2.0
3.4
50
2.4
3.8
50
3.0
4.0
80
1.4
2.8
80
2.0
3.5
80
2.5
4.0

DIMENSIONS
mm
l
540
540
540
540
540
540
540
540
540
540
540
540
540
540
540
540
540
540
540
540
540
540
540
540
540
540
540
540
540
540
540
540
540
540
540
540
540
540
540
540

a
255
255
255
255
255
255
255
255
255
255
255
255
255
255
255
255
255
255
255
265
265
265
315
315
315
315
315
315
290
290
290
255
255
255
255
255
255
255
255
255

h
475
480
490
490
510
580
580
595
595
538
562
562
510
510
510
510
509
509
509
497
497
497
515
515
515
515
515
515
545
545
545
509
509
509
539
539
539
539
539
539

DN2

PORTS

DN1

TYPE

BOOSTER SETS-24 CY COMPONENTS


- Single-phase pump
- 20 litre cylindrical vessel
- Hose
- Pressure switch SQUARE-D
- Pressure gauge
- 3 or 5-way brass connector
- 1.5 metre cable with Schuko plug

(1) Maximum flow rate with the minimum recommended


pressure switch settings
(2) Pressure switch recommended rate
N.B. The pre-charge of air in diaphragm tanks must be set to a value 0.2 bar
lower than the minimum setting of the pressure switch.

80

BOOSTER SETS-60CY
Pressure sets with 60 litre cylindrical vessel, for automatic operation.
Suitable for the supply of pressurised water in houses.

PERFORMANCE AND DIMENSIONS

Single-phase

suc. deliv.

POWER
kW

HP

FLOW
SETTING
RATE (recommended)
(1)
(2)
l/min
min
max

DIMENSIONS
mm
l

60CY/IC 100MH

0.75

90

1.8

3.2

750

380

720

60CY/IC 150M

11/4

1.1

1.5

120

2.2

3.5

750

380

735

60CY/IC 150LM

11/4

1.1

1.5

150

2.0

3.5

750

380

735

60CY/ICB 100NM

11/4

0.75

100

1.4

2.8

750

380

678

60CY/ICB 150HM

11/4

1.1

1.5

100

2.2

3.6

750

380

702

60CY/ICB 150MM

11/2

1.1

1.5

140

2.2

3.6

750

380

702

60CY/MSG 10M

0.75

100

3.5

750

380

650

60CY/JS 10HM

0.75

50

2.0

3.2

750

380

655

60CY/JS 12HM

0.90

1.25

50

2.5

4.0

750

380

655

60CY/JS 15HM

1.1

1.5

50

3.0

4.5

750

380

655

60CY/JS 10LM

0.75

80

1.4

2.8

750

380

655

60CY/JS 12LM

0.90

1.25

80

2.0

3.5

750

380

655

60CY/JS 15LM

1.1

1.5

80

2.5

4.0

750

380

655

60CY/JSE 15HM

11/4

1.1

1.5

70

3.0

4.5

750

380

685

60CY/JSE 15MM

11/4

1.1

1.5

120

2.0

3.5

750

380

685

60CY/JSE 15LM

11/4

1.1

1.5

160

1.4

2.8

750

380

685

60CY/JET 10 HMSS

11/4

0.75

50

2.0

3.4

750

380

679

60CY/JET 12HMSS

11/4

0.90

1.25

50

2.4

3.8

750

380

679

60CY/JET 15HMSS

11/4

1.1

1.5

50

3.0

4.0

750

380

679

60CY/JET 10LMSS

11/4

0.75

80

1.4

2.8

750

380

679

60CY/JET 12LMSS

11/4

0.90

1.25

80

2.0

3.5

750

380

679

60CY/JET 15LMSS

11/4

1.1

1.5

80

2.5

4.0

750

380

679

DN2

DN1

PORTS

TYPE

BOOSTER SETS-60 CY COMPONENTS


- Single-phase pump
- 60 litre cylindrical vessel
- Hose
- Pressure switchSQUARE-D
- Pressure gauge
- 3 or 5-way brass connector
- 1.5 metre cable with Schuko plug

(1) Maximum flow rate with the minimum recommended


pressure switch settings
(2) Pressure switch recommended rate
N.B. The pre-charge of air in diaphragm tanks must be set to a value 0.2 bar
lower than the minimum setting of the pressure switch.

81

BOOSTER SETS-100CY
Pressure sets with 100 litre cylindrical vessel, for automatic operation.
Suitable for the supply of pressurised water in houses.

PERFORMANCE AND DIMENSIONS

POWER

suc. deliv.

kW

HP

100CY/IC 150M

11/4

1.1

1.5

100CY/150 LM

11/4

1.1

100CY/ICB 100NM

11/4

0.75

100CY/ICB 150HM

FLOW
SETTING
RATE (recommended)
(1)
(2)
l/min
min
max

DIMENSIONS
mm
l

3.5

860

450

800

2.0

3.5

860

450

800

1.4

2.8

860

450

743

120

2.2

1.5

150

100

11/4

1.1

1.5

100

2.2

3.6

860

450

767

100CY/ICB 150MM 11/2

1.1

1.5

140

2.2

3.6

860

450

767

100CY/MSG 10M

0.75

100

3.5

860

450

715

100CY/JS 10HM

0.75

50

2.0

3.2

860

450

720

100CY/JS 12HM

0.90

1.25

50

2.5

4.0

860

450

720

100CY/JS 15HM

1.1

1.5

50

3.0

4.5

860

450

720

100CY/JS 10LM

0.75

80

1.4

2.8

860

450

720

100CY/JS 12LM

0.90

1.25

80

2.0

3.5

860

450

720

100CY/JS 15LM

1.1

1.5

80

2.5

4.0

860

450

720

100CY/JSE 15HM

11/4

1.1

1.5

70

3.0

4.5

860

450

750

100CY/JSE 15MM

11/4

1.1

1.5

120

2.0

3.5

860

450

750

100CY/JSE 15LM

11/4

1.1

1.5

160

1.4

2.8

860

450

750

100CY/JET 10 HMSS 11/4

0.75

50

2.0

3.4

860

450

744

100CY/JET 12HMSS 11/4

0.90

1.25

50

2.4

3.8

860

450

744

100CY/JET 15HMSS 11/4

1.1

1.5

50

3.0

4.0

860

450

744

100CY/JET 10LMSS 11/4

0.75

80

1.4

2.8

860

450

744

100CY/JET 12LMSS 11/4

0.90

1.25

80

2.0

3.5

860

450

744

100CY/JET 15LMSS 11/4

1.1

1.5

80

2.5

4.0

860

450

744

DN2

Single-phase

PORTS

DN1

TYPE

BOOSTER SETS-100 CY COMPONENTS


- Single-phase pump
- 100 litre cylindrical vessel
- Hose
- Pressure switch SQUARE-D
- Pressure gauge
- 3 or 5-way brass connector
- 1.5 metre cable with Schuko plug

(1) Maximum flow rate with the minimum recommended


pressure switch settings
(2) Pressure switch recommended rate
N.B. The pre-charge of air in diaphragm tanks must be set to a value 0.2 bar
lower than the minimum setting of the pressure switch.

82

NOTE

The features and specifications herein stated are in no way binding for the manufacturer.
The manufacturer is free to modifiy the product at any time without previous notice.

83

Ufficio immagine & comunicazione cod. C105022006

You might also like