You are on page 1of 12

6FM100P-X

12V 100Ah(10hr)

The rechargeable batteries are lead-lead dioxide systems. The dilute sulfuric acid
electrolyte is absorbed by separators and plates and thus immobilized. Should the
battery be accidentally overcharged producing hydrogen and oxygen, special oneway valves allow the gases to escape thus avoiding excessive pressure build-up.
Otherwise, the battery is completely sealed and is, therefore, maintenance-free,
leak proof and usable in any position.
Battery Construction
Component

Positive plate

Negative plate

Container

Cover

Safety valve

Terminal

Separator

Electrolyte

Raw material

Lead dioxide

Lead

ABS

ABS

Rubber

Copper

Fiberglass

Sulfuric acid

General Features

Advanced pure lead technology.

Longer float & cycle life, longer warranty.

Stronger discharge performance.

Special design to avoid thermal runaway.

Excellent consistency and reliability.

Can be mounted in any orientation.

Maintenance-free operation.

Low self discharge.

Case and cover avaiable in both standard


and flame restardant ABS.

Dimensions and Weight


Length(mm / inch)
Width(mm / inch)
Height(mm / inch)
Total Height(mm / inch)
Approx. Weight(Kg / lbs)

339 / 13.35
173 / 6.81
214.5 / 8.44
220 / 8.66
27.5 / 60.6

* Weight deviation: 3%

Performance Characteristics
Nominal Voltage
Number of cell
Design Life
Nominal Capacity 77oF(25oC)

12V
6
10 years

10 hour rate (10.0A, 10.8V)


100Ah
5 hour rate (17.5A, 10.5V)
87.5 Ah.
1 hour rate (66.2A,9.6V)
66.2 Ah
Internal Resistance
5.7mOhms
Fully Charged battery 77oF(25oC)
Self-Discharge
3% of capacity declined per month at 20oC(average)
Operating Temperature Range
Discharge
-20~60oC
Charge
-10~60oC
Storage
-20~60oC
900A(5s)
Max. Discharge Current 77oF(25oC)
Short Circuit Current

2500A

Charge Methods: Constant Voltage Charge 77oF(25oC)


2.40-2.45VPC
Cycle use
Maximum charging current
30A
Temperature compensation
-30mV/oC
Standby use
2.20-2.30VPC
Temperature compensation
-20mV/oC

Discharge Constant Current (Amperes at 77oF25oC)


3391

214.51
2201

1731

End Point
Volts/Cell

5min

10min

15min

30min

1h

3h

5h

10h

20h

1.60V

314

229

185

108

66.2

27.9

19.0

10.8

5.50

1.65V

296

221

178

104

62.5

27.7

18.3

10.6

5.45

1.70V

270

200

164

96.0

61.5

27.2

18.0

10.5

5.40

1.75V

242

187

153

93.0

60.5

26.9

17.5

10.3

5.35

1.80V

221

175

143

91.0

57.4

25.3

17.2

10.0

5.30

Discharge Constant Power (Watts at 77 oF25oC)


End Point
Volts/Cell

44

16

266

M8

5min

10min

1.60V

547

1.65V

517

1.70V

15min

30min

45min

1h

3h

5h

10h

392

321

199

150

124

52.8

35.8

20.3

379

315

188

146

118

51.2

35.4

20.1

478

360

299

183

137

114

50.9

35.0

20.0

1.75V

441

353

294

177

134

111

49.1

34.4

19.6

1.80V

415

329

279

171

131

104

48.5

34.0

19.1

(Note)The above characteristics data are average values obtained within


three charge/discharge cycles not the mimimum values.
All data shall be changed without notice,Vision reserves the right to explain
and update the information contained hereinto.

www.vision-batt.com
page1 of 2

6FM100P-X

12V100Ah

Discharge characteristic (25 C)

Constant voltage charging


characteristic (0.25CA,25 oC)
(%) (XCA) (V)

12.0

140

26.9A

17.5A10.0A

120

0.25

100

0.20

80

9.6

200A

100A 66.2A

0.15

5
10
min

20 30

60

10

20

0.10

20

0.05

14.0

CHARGE VOLTAGE

13.0

60
40

15.0

12.0
11.0

CHARGING CURRENT

Discharge time

10

12

14

16

18

20

Charging time (hours)

Self-discharge characteristic

Relationship between
charging voltage and temperature

110
100
90

15.6

10.4

7.8

5.2

2.6

15.0

10.0

7.5

5.0

2.5

14.4

9.6

7.2

4.8

2.4

13.8

9.2

6.9

4.6

2.3

13.2

8.8

6.6

4.4

2.2

80
70
60
50

-10

10

20

30

40

50

40

60

Ambient temperature( oC)

8
10
12
14
Storage time: months

16

18

20

Cycle service life in relation to


depth of discharge

Life characteristics of Standby use


120

120
100

100

Capacity(%)

80

60

2.20

2.30

80
60

40

40

20

20

6
Life(year)

300

Temperature effects on float life

600

900
1200
1500
Number of cycles(cycles)

1800

2100

Temperature effects on capacity


120

15

100
Capacity (%)

2.30

10

0.1C
0.2C
0 .3 C

80
60

1 .0 C

40

2 .0 C

20
0

50%D.O.D 30%Depth of discharge

80%D.O.D

10

20

30

40

50

0
-20

Temperature( oC)

THE INTERNATIONAL CERTIFICATION NETWORK

ISO9001:2008

MH25860

-10

10
20
Temperature( oC)

30

40

G4M19906-9202-E-16

www.vision-batt.com

Shenzhen Center Power Tech. Co., Ltd.


Center Power Industrial Park, Tongfu Industrial District Dapeng Town, 518120 Shenzhen, China
Tel: (+86-755) 8431 8088 Fax: (+86-755) 8431 8038 E-mail: sales@vision-batt.com
Copy Right Shenzhen Center Power Technology Co., Ltd (Edition 2013-8)

Page 2 of 2

50

6FM150E-X 12V 150Ah(10hr)


The rechargeable batteries are lead-lead dioxide systems. The dilute sulfuric acid
electrolyte is absorbed by separators and plates and thus immobilized. Should the
battery be accidentally overcharged producing hydrogen and oxygen, special oneway valves allow the gases to escape thus avoiding excessive pressure build-up.
Otherwise, the battery is completely sealed and is, therefore, maintenance-free,
leak proof and usable in any position.
Battery Construction
Component

Positive plate

Negative plate

Container

Cover

Safety valve

Terminal

Separator

Electrolyte

Raw material

Lead dioxide

Lead

ABS

ABS

Rubber

Copper

Fiberglass

Sulfuric acid

Performance Characteristics

General Features

Absorbent Glass Mat (AGM) technology


for efficient gas recombination of up to
99% and freedom from electrolyte
maintenance or water adding.
Not restricted for air transport-complies
with IATA/ICAO Special Provision A67.
UL-recognized component.
Can be mounted in any orientation.
Computer designed lead, calcium tin alloy
grid for high power density.
Long service life, float or cyclic
applications.
Maintenance-free operation.
Low self discharge.

Dimensions and Weight


Length(mm / inch)
Width(mm / inch)
Height(mm / inch)
Total Height(mm / inch)
Approx. Weight(Kg / lbs)

482 / 19.0
170 / 6.69
240 / 9.45
240 / 9.45
44.8 / 98.8

Nominal Voltage
12V
Number of cell
6
Design Life
10 years
o
o
Nominal Capacity 77 F(25 C)
10 hour rate (15.0A, 10.8V)
150Ah
5 hour rate (24.5A, 10.5V)
122.5Ah
1 hour rate (103A, 9.6V)
103Ah
Internal Resistance
3.5mOhms
Fully Charged battery 77oF(25oC)
Self-Discharge
3% of capacity declined per month at 20oC(average)
Operating Temperature Range
Discharge
-20~60oC
Charge
-10~60oC
Storage
-20~60oC
970A(5s)
Max. Discharge Current 77oF(25oC)
Short Circuit Current

2800A

Charge Methods: Constant Voltage Charge 77oF(25oC)


Cycle use
2.40-2.45VPC
Maximum charging current
40A
Temperature compensation
-30mV/oC
Standby use
2.20-2.28VPC
Temperature compensation
-20mV/oC
Discharge Constant Current (Amperes at 77oF25oC)
End Point
Volts/Cell
1.60V
1.65V
1.70V
1.75V
1.80V

10min 15min 30min


340
322
303
285
274

283
268
254
239
230

186
177
167
158
153

1h

3h

5h

10h

20h

103
98.7
94.1
89.2
87.2

42.9
41.1
39.3
37.4
36.7

27.6
26.4
25.3
24.5
23.7

15.4
15.3
15.2
15.1
15.0

8.07
8.03
7.98
7.93
7.88

Discharge Constant Power (Watts at 77oF25oC)


End Point
Volts/Cell
1.60V
1.65V
1.70V
1.75V
1.80V

10min 15min 30min 45min


605
583
560
537
515

505
487
470
452
435

329
318
308
297
286

241
234
227
220
212

1h

2h

3h

5h

186
182
178
174
170

109
107
104
101
97.6

79.2
77.2
75.2
73.3
71.3

53.7
52.4
51.0
50.0
48.8

(Note)The above characteristics data are average values obtained within


three charge/discharge cycles not the mimimum values.
All data shall be changed without notice,Vision reserves the right to explain
and update the information contained hereinto.

page1 of 2

www.vision-batt.com

Current

Charged
Volume

Discharge characteristic (25 C)

Voltage

6FM150E-X

12V 150Ah

Constant voltage charging


o
characteristic (0.25CA,25 C)

(%) (XCA) (V)


Battery voltage(V)

12.0

140

37.4A 24.5A

15.0A

120

0.25

100

0.20

80

0.15

9.6

300A

0.10

40
0

20 30

5
10
min

60

10

20

20

0.05

CHARGED VOLUME

14.0

CHARGE VOLTAGE

13.0

60

150A 103A

15.0

12.0
11.0

CHARGING CURRENT

Discharge time

12

14

16

18

20

110

(V/CELL)

100

15.6

10.4

7.8

5.2

2.6

15.0

10.0

7.5

5.0

2.5

14.4

9.6

7.2

4.8

2.4

Capacity(%)

(V/6V)

(V/4V)

(V/8V)

10

Self-discharge characteristic

Relationship between
charging voltage and temperature
(V/12V)

Charging time (hours)

90
80
70

13.8

9.2

6.9

4.6

2.3

60

13.2

8.8

6.6

4.4

2.2

50

-10

10

20

30

40

50

40

60

Ambient temperature( oC)

8
10
12
14
Storage time: months

16

18

20

Cycle service life in relation to


depth of discharge

Life characteristics of Standby use


120

120
100
Capacity(%)

Capacity(%)

100

80

60

80
60

40

40

20

20

6
Life(year)

30% Depth of discharge

200

Temperature effects on float life

400
600
800
1000
Number of cycles(cycles)

1200

1400

Temperature effects on capacity

15

120

Capacity (%)

Life(years)

100
10

80
60
40
20

10

20

30

40

0
-20

50

-10

10

20

30

40

Temperature( oC)

THE INTERNATIONAL CERTIFICATION NETWORK

ISO9001:2008

MH25860

G4M19906-9202-E-16

www.vision-batt.com

Shenzhen Center Power Tech. Co., Ltd.


Center Power Industrial Park, Tongfu Industrial District Dapeng Town, 518120 Shenzhen, China
Tel: (+86-755) 8431 8088 Fax: (+86-755) 8431 8038 E-mail: sales@vision-batt.com
Copy Right Shenzhen Center Power Technology Co., Ltd (Edition 2014-1)

Page 2 of 2

50( o C)

You might also like