You are on page 1of 1

1

10

11

12

A01

MD-512-09EA-EG-CV-DGA-2002
DRAWING NUMBER

REV

IN-SITU CONCRETE

DOWEL BARS

A
HYDROTITE EXPANDING

CLEAN

WATER SEAL

WATER POND
PAP

300

(SEE NOTE 7)

O.
D.

600

44800

PI
PE

9200 800

DI
A.

600

PI
PE

175400

300

500

800

EASTING = 1062.20

HYDROTITE EXPANDING

NORTHING = 4468.00

SPARE AREA

(SEE NOTE 7)

SUB/
MCC
&I
TR

WATER SEAL

10 DIA. REINFORCING
IN-SITE CONCRETE WALL
BARS
B

DOWEL BARS

KEY PLAN
TYPICAL CAST-IN PIPE

37250

37250

NOTES:
1. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS OTHER SPECIFIED.
2. ALL LEVELS ARE IN METERS UNLESS OTHER SPECIFIED
3. REFER TO MD-512-09EA-EG-CV-DLA-2004 FOR PIPEWORKS
ARRANGEMENTS.
4. EARTHWORKS FOR CONTAMINATED POND SHOULD BE IN
SAFETY RAILING BOLTED TO

CONCURRENCE WITH MA`ADEN ENGINEERING MANUAL

CONCRETE UPSTAND AROUND

MD-101-SMEM-EG-CV-SPC-0001.
5. CONTAMINATED POND TO BE REINFORCED CONCRETE IN

(
TYP)

+100.000

900

75900

WHOLE TANK PERIMETER

CONCURRENCE WITH MA`ADEN ENGINEERING MANUAL


MD-101-SMEM-EG-ST-SPC-0005.
6. PROTECTIVE COATING FOR CONCRETE SHOULD BE IN CONCURRENCE

C
300mm SAND BED EXTENT OF POND

WITH ASTM C811 & ASTM C722 AS SPECIFIED IN MA`ADEN

ABOVE COMPACTED SUB-GRADE

ENGINEERING MANUAL MD-101-SMEM-EG-ST-SPC-0008.

OUT FALL
HDPE LINER

3205

1.5mm THK

7. HYDROTITE EXPANDING WATER SEAL TO BE BONDED TO THE PIPE

100mm SAND BED

97.545

100

850

95.945

1600

ABOVE REINFORCED

A
-

SURFACE TO PROVIDE A WATER TIGHT SEAL.

EXTENT OF POND
600

PIPE

CONCRETE FOOTING

COMPACTED
SUB-GRADE (TYP)

800

600

9200

DETAIL

01

SCALE 1:100

PLAN

SCALE 1:500

SAFETY RAILING AND PIPEWORK OMITTED FOR CLARITY

02

01

800

300

+100.000

HDPE LINER 1.5mm THK


100mm SAND BED

CONCRETE FOOTING

3055

ABOVE REINFORCED

+98.145

800

96.945

COMPACTED SUB-GRADE (TYP)


7500

C:
\TEMPO\00\NL6945\90\I
S01a\2013\A01\NL694590I
S01A2013.
DGN

300MM SAND BED EXTENT

800 800

OF POND ABOVE COMPACTED


SUB-GRADE

DETAIL

SCALE 1:500

DETAIL
SCALE 1:100

02
-

DISCLAIMER:The following report has been prepared by the Consultant for the Employer and is the property of the Employer.It is based in part on information not within the
Consultant's control. It is believed that the estimates and conclusions contained therein will be reliable under the conditions and subject to the qualifications set
forth, however, the Consultant does not warrant or guarantee their accuracy. Use of such report by any third party shall, herefore, be at the user's sole risk.
Such use shall constitute a release and agreement by such third party to waive any liability against the Consultant in connection with such use. Such release
from liability shall apply in contract, tort (including negligence of the Consultant), strict liability or other theory of legal liability, provided, however such release
andlimitation and limitation on liability shall be effective to and only to the maximum extent, scope or amount allowable by law.

11:
38:
37 AM

PROPRIETARY & CONFIDENTIAL

DRAWN

M. PALKAR

16/09/2014

CHECKED

P.JOSHI

16/09/2014

ENGINEER

J. SILEKAR

16/09/2014

CLEAN STORM WATER POND

This document and the information contained

herein is Ma'aden proprietary know-how.

MD-101-SMEM-EG-ST-SPC-0008

PROTECTIVE COATING FOR CONCRETE

This document or any part thereof should not

MD-101-SMEM-EG-ST-SPC-0005

CONCRETE WORKS

be reproduced, stored in a retrieval system

UMM WU'AL PHOSPHATE PROJECT


H

GENERAL ARRANGEMENT
APPROVED

B. DALAL

16/09/2014

12/5/2014

or transmitted by any means, electronic or

MD-101-SMEM-EG-CV-SPC-0001

EARTHWORKS

MD-512-09EA-EG-CV-DLA-2006

CLEAN STORM WATER NETWORK (NORTH)

EMPLOYER

otherwise, or divulged without prior written

A01 02/12/2014

ISSUED FOR APPROVAL

M.P. P.J. J.S. B.D.

DRAWING NUMBER

permission of Ma'aden.

SCALE
DOCUMENT NUMBER
1

JPI No.NL6945-90/IS.01a/2013

REFERENCE DOCUMENTS
2

REV
3

DATE

REVISION DESCRIPTION
4

DRN
5

CHK

ENG APP EMP


6

AS SHOWN
10

A1

REV

MD-512-09EA-EG-CV-DGA-2002
11

12

A01

You might also like