You are on page 1of 65

NODE B COMMISSIONING

OPERATION AND
MAINTAINENCE

RATINDER SINGH | EILL

BEFORE COMMISSIONING OF
NODEB FOLLOWING
REQUIREMENTS:SOFTWARE:1) HYPER TERMINAL
2) FTP SOFTWARE LIKE WIN
COMMANDER, WSFTP ETC.
3) BPFTP SERVER.
4) CMD.
5) UPDATED JAVA AS PER OS.
RATINDER SINGH | EILL

6) UP FOLDER CONTAINIG :A) INITIAL CV.


B) P5 SOFTWARE.
C) P6 SOFTWARE.
SCRIPTS REQUIRED
1) EXTERNAL HARDWARE.
2) O&M SCRIPT.
3) IUB_NODE B.
4) IUB_NODEB_RNC.
5) ADD CELL_NODEB_RNC.
RATINDER SINGH | EILL

FEW CONCEPTS BEFORE START


1) HYPER TERMINAL WILL BE USED

FOR CONNECTING NODE B TO


LAPTOP VIA COM PORT.
2) UP FOLDER MUST BE PLACED ON C
DRIVE ON LAPTOP.
3) EVERY TIME WHEN COMMISSIONING
THE NODEB FIRST LOAD P5 AND
THEN UP GRADE TO P6.

RATINDER SINGH | EILL

4) WE CAN RUN SCRIPTS ON P6 OR P5.THE


EXTERNAL HARDWARE AND O&M SCRIPTS
ARE ALMOST SAME FOR P5 AND P6 BUT A
SMALL PATCH OF CREATING IUB LINK
WILL BE ADDED TO IUB_NODEB WHEN
RUNNING P6 IUB IN P5 PLATFORM AND
VISE VERSA.
5) THE INITIAL IP WILL BE DEFINED AS
169.254.1.1 AND WILL CHANGE AFTER THE
EXECUTION OF O&M SCRIPT.
RATINDER SINGH | EILL

O&M SCRIPT ADDS 3 IP IN NODE B.

FIRST ONE IS USED FOR ETHERNET


CONNECTION AND OTHER TWO ARE
USED FOR ATM OVER IP
CONNECTIVITY.

RATINDER SINGH | EILL

HOW TO READ DLD FORM


1) IN ATM ADDRESS SEE THE NODE B AND
CORRESPONDONG IUB WITH A2EA.

2) RNC_IUB SHEET FOR DIRECT TO RNC SITES. USE


IUB NO. FOR SEARCHING THE ATM PORT.

3) HUB AND SUB HUB_IUB SHEET FOR NODE B


CONNECTED THROUGH HUB, SUB HUB
TOPOLOGY.

RATINDER SINGH | EILL

4) MUB_CC SHEET FOR FINDING THE


VC THAT ARE USED FOR CROSS
CONNECTING RNC WITH MGW.
ALSO, FOR GETTING ATM AND
ETHERNET IP FOR NODE B AND
ROUTER.
RATINDER SINGH | EILL

STEPS
FOR COMMISSIONIG OF
NODE B

RATINDER SINGH | EILL

OPEN HYPER TERMINAL AND


GIVE ANY CONNECTION NAME

RATINDER SINGH | EILL

SELECT THE COM PORT USED


FOR CONNECTION

RATINDER SINGH | EILL

GIVE USER NAME AND


PASSWARD-----rbs

RATINDER SINGH | EILL

GIVE COMMAND ( reload --)


FOR GETTING INTO THE BACKUP MODE AND
THEN ( formathd /c2, formathd /d)
FOR FORMATTING c2 AND d DRIVES
NOTE:- DRIVE VOLUMES CAN BE CHECKED WITH ( vols ) COMMAND. IT SHOULD
BE 0M FOR BOTH DRIVES

RATINDER SINGH | EILL

GIVE POWER RESTART TO THE


NODE

RATINDER SINGH | EILL

GIVE IP TO THE NODE WITH COMMAND


( ifconfig le0 169.254.1.1 netmask
255.255.0.0)

RATINDER SINGH | EILL

GIVE NODE IP IN NETWORK


CONNECTIONS

RATINDER SINGH | EILL

OPEN WIN COMMANDER

RATINDER SINGH | EILL

GO TO FTP CONNECTIONS

RATINDER SINGH | EILL

GIVE NODE IP. GIVE USER


NAME AND PASSWARD AS rbs

RATINDER SINGH | EILL

DRAG c2 AND d FOLDERS FROM INITIAL_CV_NODEB


TO O DRIVE WHERE c2 AND d DRIVES ARE
ALREADY PRESENT

RATINDER SINGH | EILL

WAIT TILL TRANSFER OF FILES


IS COMPLETED

RATINDER SINGH | EILL

OPEN CMD AND GIVE PATH WHERE


sw_load.bat FILE IS STORED

RATINDER SINGH | EILL

RUN COMMAND sw_load.bat 169.254.1.1


rbs rbs AND WAIT TILL service closing
control connection

RATINDER SINGH | EILL

GIVE reload AND WAIT TILL


LOGIN SERVER READY

RATINDER SINGH | EILL

OPEN INTERNET EXPLORER. GIVE


ADDRESS
169.254.1.1/em/index.html

RATINDER SINGH | EILL

GO TO CONFIGURATION VERSION
AND CREATE CV AS p5

RATINDER SINGH | EILL

IN UPGRADE PACKAGE FILL DATA AS SHOWN IN


SLIDE
NOTE:- FORMAT OF SOFTWARE FILE NAME
./filename.xml

RATINDER SINGH | EILL

OPEN BPFTP SERVER AND MAKE USER


ACCOUNT AS anonymous
WITH PASSWORD anonymous

RATINDER SINGH | EILL

GIVE PATH WHERE FILE IS


SAVED ON HARD DISK

RATINDER SINGH | EILL

AFTER CREATING THE PACKAGE


CLICK ON install package
THEN full install

RATINDER SINGH | EILL

VERIFY PACKAGE

RATINDER SINGH | EILL

THEN upgrade node AND


THEN hard upgrade

RATINDER SINGH | EILL

WHEN THE UPGRADE IS COMPLETED THEN OPEN


INTERNET EXPLORER AND GIVE
169.254.1.1/em/index.html TO DOWNLOAD RBS
ELEMENT MANAGER

RATINDER SINGH | EILL

OPEN RBS ELEMENT MANAGER


AND GIVE IP TO CONNECT TO
NODE

RATINDER SINGH | EILL

GO TO UPGRADE PACKAGE
AND confirm P6 UPGRADE

RATINDER SINGH | EILL

IN C0NFIGURATION VERSION
CREATE CV NAMED AS cv_p6

RATINDER SINGH | EILL

GO TO CABINET EQUIPMENT
AND SELECT delete cabinet
equipment

RATINDER SINGH | EILL

AGAIN GOTO CABINET


EQUIPMENT

RATINDER SINGH | EILL

THEN DO next TILL IT LOADS


CURRENT CONFIGURATIONS

RATINDER SINGH | EILL

SELECT RB1 IN ALL 3


SECTORS

RATINDER SINGH | EILL

SELECT CARDS PRESENT ON

RATINDER SINGH | EILL

PROCEED NEXT TILL IT DIPLAYS THE


NODE DATA THAT WE HAVE DEFINED

RATINDER SINGH | EILL

CLICK FINISH AND IT DISPLAYS GIVEN


MESSAGE AND AGAIN CLICK YES

RATINDER SINGH | EILL

NOW GO TO SITE EQUIPMENT AND TICK use


configuration file GIVE FILE PATH WHERE
external hardware SCRIPT IS STORED

RATINDER SINGH | EILL

WAIT TILL IT LOADS


CONFIGURATION FILE

RATINDER SINGH | EILL

CLICK NEXT TILL PAGE 7.


IF WE ARE USING TRI BAND OR DUAL BAND ANTENNA THEN
( ANTENNA TYPE IS 0 AND RET TYPE IS ARETU FOR ALL 3
SECTORS) ELSE (ANTENNA TYPE = 5 AND RET TYPE = ARETU)

RATINDER SINGH | EILL

ON PAGE 9 FILL THE DELAY AND


ATTENUATION AS CALCULATED WITH BASIC
CALCULATOR

RATINDER SINGH | EILL

DO NEXT UNTIL IT DISPLAYS THE DATA


ENTERED BY MEANS OF SCRIPT AND BY
MANUAL FEEDING

RATINDER SINGH | EILL

CLICK FINISH AND WAIT UNTIL IT GIVES


MESSAGE CONFIGURATION COMPLETED
SUCCESSFULLY

RATINDER SINGH | EILL

NOW, GO TO O&M ACCESS .


GIVE FILE PATH AND SELECT WIZARD

RATINDER SINGH | EILL

CLICK NEXT AND ALSO CROSS CHECK THE


DATA DISPLYED AND THEN CLICK FINISH

RATINDER SINGH | EILL

BEFORE PROCEEDING.
CHANGE THE IP ADDRESS
AND SUBNET MASK IN
NETWORK CONNECTIONS

RATINDER SINGH | EILL

NOW GOTO RUN COMMAND


FILE

RATINDER SINGH | EILL

TICK HALT ON ERRORS AND VERBOSE


LOGGING ALSO GIVE PATH WHERE iub
SCRIPT IS STORED.

RATINDER SINGH | EILL

CLICK START AND WAIT TILL


CONFIGURATION SUCCEEDED
MESSAGE IS DIPLAYED

RATINDER SINGH | EILL

NOW GOTO LICENSING THEN


UPDATE KEY FILE

RATINDER SINGH | EILL

GIVE USER ID license PASSWD license IP


ADDRESS= IP ADDRESS +1 AND LICENSE FILE =
LICENSE FILE NAME.xml

RATINDER SINGH | EILL

IN BPFTP SERVER MAKE NEW USER ACCOUNT AS


license AND PASSWD AS license. ALSO, GIVE
THE PATH WHERE LICENSE OF GIVEN SITE IS
STORED.
THEN CLICK OK IN UPDATE LICENSE KEY WINDOW

RATINDER SINGH | EILL

IT FINSHES THE
COMMISSIONING OF NODE-B
WHETHER INDOOR OR
OUTDOOR. AFTER THIS
SCRIPTS REGARDING RF
PARAMETERS, RET AND DELAY
AND ATTENUATION HAVE TO
BE DEFINED. ALSO,IF SINGLE
BAND ANTENNA IS USED THEN
SOFTWARERATINDER
UPGRADATION
IS
SINGH | EILL

FROM O&M POINT OF VIEW FOLLOWING POINTS


ARE VERY IMPORTANT
MEDIA TESTING

1) CHECK THE EXACT POSITION OF E1


TERMINATED ON NODEB.

2) CHECK ATM PORT:- IN ATM SEE ATMPORT

AND VC DEFINED UNDER IT ARE ENABLED


AND OPERATIONAL.

3) NBAP DEDICATED AND COMMON:- CHECK


ENABLED AND OPERATIONAL.
RATINDER SINGH | EILL

EQUIPMENT

1) CHECK ALL THE CARDS ARE UNLOCKED AND


ENABLED.

2) IF ANY CARD IS NOT WORKING PROPERLY, THEN


LOCK ANDTEST IT FROM BOARD TEST.

3) SEE RETU ARE ENABLED AND UP.


4) SEE OPERATIONAL LED STABLE IN ALL CARDS AND
WHEN NODE B IS RADIATING INFORMATION IS
BLINKING IN ALL CARDS EXCEPT ETXX CARDS
WHICH ARE USED FOR TRANSMISSION PURPOSES.

RATINDER SINGH | EILL

5) CHECK SECTORS:- IN RADIO


NETWORK CHECK ALL SECTORS AND
CORRESPONDING CARRIERS ARE
ENABLED AND OPERATIONAL

RATINDER SINGH | EILL

IP
1) CHECK ETHERNET IP IS

OPERATIONAL AND SAME AS


GIVEN IN DLD FORM.

2) CHECK BOTH THE IP DEFINED FOR


ATM OVER IP ARE OPERATIONAL.

RATINDER SINGH | EILL

ALARMS
AT LAST THE MOST IMPORTANT
THING FROM O&M POINT OF VIEW
IS THE ALARMS ON NODE B WHICH
ARE VERY IMPORTANT AND WILL
BE RECTIFIED AS SOON AS
POSSIBLE. IF UNABLE TO DO SO,
THEN ESCALATE TO HIGHER LEVEL
FOR RECTIFICATION.
RATINDER SINGH | EILL

RATINDER SINGH | EILL

You might also like