You are on page 1of 3

PCM -INDEX-

Chinese Website

Company

News

Products Support Download Contact

Home > Product > On-Line UPS > Vanguard 6000/8000/10000

Off-Line UPS

Vanguard 6000/8000/10000

Line Interactive

Multi Functional LCD On-Line UPS.

On-Line UPS

15 LCD Display:
Easy viewing of UPS status from LCD panel including:

Inverter
O/P Voltage

O/P Load (%)

Battery Charge (%)

AVR

O/P Frequency

O/P Watt (W)

Temperature (C)

Surge Protection

I/P Voltage
I/P Frequency
Battery Voltage

O/P VA
O/P Current (A)
Back Up Time (Min.)

Battery Pack Number


Rating (A)
CPU Version

UPSMON

14 UPS parameter settings:


O/P Voltage

Other UPS
VGD-6K-8K-10K-LCD
Front View | Back View
Back View

Vanguard 6K (3U)

Vanguard 6K Battery Pack (3U)


Rack mount model available w

http://www.pcmups.com.tw/product/vanguard6000.html (1 of 3)23/02/2006 13:53:33

O/P Load (%)

Battery Charge (%)

O/P Frequency

O/P Watt (W)

Temperature (C)

I/P Voltage

O/P VA

Battery Pack Number

I/P Frequency

O/P Current (A)

Rating (A)

Battery Voltage

Back Up Time (Min.)

CPU Version

Unique Design :
- Vanguard rack mount models come in different heights such as 1U,
2U, or 3U to meet different space demands.
- Vanguard rack mount now is availabl from 700VA up to 10KVA
- Vanguard 3U rack mount model is designed to be flexible and able
to fit in different spaces.
- The control panel can be adjusted 90 degree around to
accommodate the UPS installation direction (vertically or horizontally)
- Remote control panel feature is designed for easy control of the
UPS which is placed in the unreachable area.
- The display panel can be remove from the front panel and attached
to the back panel with a cable in order to provide the wired-remote
feature.
- 2 different directions of insertion slots are designed to attached with
display panel providing 2 different angels to suit in different space
demands.

PCM -INDEX-

FEATURES:

Cold start function (DC power on)


Lightning and surge protection
Battery replacement warning
Schedule shutdown & reboot
Hot swappable battery by user
Emergency Power Off function
Battery remain time display
LCD display front panel
Optional SNMP Card slot
Wide input voltage range
Power factor correction
Manual bypass setting
Free run mode setting
EMI/RFI noise filter
Support USB communication
Multiple language LCD display
On line output voltage selected

Tower Model (With LCD Display)


19" Rack-Mount Model
Capacity (VA)
Capacity (W)

True on-line technology provides all power protection


Pure sine-wave output with less than 3% THD
Fully digitized microprocessor controlled
Short Circuit and overload protection
Advanced battery management (ABM)
Automatic battery charge in UPS off mode
Automatic diagnostics & battery check
RS-232 communication port with monitoring software
Network/fax/modem surge protection
History record of power failure events
UPSMON plus software monitoring
Extended back up time with battery pack
Optional Extension battery pack
Load segmentation receptacles controllable
High efficiency mode selectable
Fan speed auto control when loads varies

VGD-6000
VGD-6000 -RM
6000VA
4200W

VGD-8000
Not Available
8000VA
5600W

VGD-10000
Not Available
10000VA
7000W

208V/220V/230V/240V

INPUT

OUTPUT

PROTECTION &
FILTERING

SYSTEM
DISPLAY /
WARNING

Voltage / Range

Load Capacity

120 ~ 139V
140 ~ 159V
160 ~ 276V

0 ~ 40%
0 ~ 70%
0 ~ 100%

Voltage

Frequency
Voltage (on
battery)
Frequency (on
battery)
Transfer Time
Overload
Recovery
High Efficiency
Mode (AC to AC)
UPS Design
Technology
Output Wave
Form
Harmonic
Distortion
Crest Factor
Surge Protection
Overload
Protection
Short Circuit
Protection
Visual Display
(LED Model)
Visual Display
(LCD Model)
Audible Alarm
(Battery Back-Up)
UPS Fault
Communication
Type
DC Voltage (V)
Battery (Tower )

http://www.pcmups.com.tw/product/vanguard6000.html (2 of 3)23/02/2006 13:53:33

Voltage / Load
Range Capacity
180 ~
276V

0~100%

50 / 60 Hz Auto Sensing
100V, 110V, 120V, 127V or 208V, 220V, 230V, 240V +/-2%
(Selectable Output Voltage)
50 / 60 Hz +/-0.5%
0 ms
Auto transfer to UPS
> 98 %
On-Line / Fully digitized microprocessor controlled
Sinewave
< 3% of T.H.D. at linear load
3:1
IEEEC61000-4-5 Level 3
125% for 1 minute and 150% for 10 seconds
UPS output cut off immediately or input fuse / circuit
breakerprotection
UPS on(green), line-mode(green), battery mode(yellow), bypass
(yellow), fault(red)
Input / output voltage, input / output frequency, on-line mode, back
up mode, battery capacity, load level
Beep every 5 sec
Continuous beeping sound and LCD display
RS-232 Serial Port and USB
Sealed, maintenance-free lead acid batteries
240V / 12V7.2AH
240V / 12V7.2AH
240V / 12V9AH
x 20
x 20
x 20

PCM -INDEX-

Typical Recharge
4 hours
Time to 90% Full
Management
Self-test, adjustable battery transfer points and alarm settings
Battery Protection Cut off without draining any current when battery is low
Cold Start (DC
YES
Start)
Back Up Time
7 mins Full load / 15mins Half Load
(Tower Model)
Input lnlet
Hardwire
Receptacles
Hardwire
Tower
Dimensions
257 x 590 x 570
257 x 690 x 715
257 x 690 x 715
W/O ISO
(10.1"x23.2"x22.4")
(10.1"x27.2"x28.1")
(10.1"x27.2"x28.1")
mm (inch) WxDxH
Net Weight kg (lb)
86.0 Kg (189.2)
112 Kg (246.4)
112 Kg (246.4)
Tower w/o ISO
Shipping Weight
kg (lb)
106.0 Kg (233.2)
139.0 Kg (305.8)
139.0 Kg (305.8)
Tower w/o ISO
Tower
Dimensions
257 x 590 x 700
342 x 690 x 715
342 x 690 x 715
With ISO
(10.1"x23.2"x27.6")
(13.4"x27.1"x28.1")
(13.4"x27.1"x28.1")
mm (inch) WxDxH
Net Weight kg (lb)
123 Kg (270.6)
178 Kg (391.6)
180 Kg (396)
Tower with ISO
Shipping Weight
145 Kg (319)
210 Kg (462)
201.5Kg (443.3)
Tower with ISO
19" Rack-Mount 428 x 558 x 130 (3U)
None
None
WxDxH
(16.9" x 22.0" x 5.1")
20(44.0) Power Module
Net Weight (LB)
None
None
66(145.2) Battery
19" RM

BATTERY

PHYSICAL

Module

ENVIRONMENT

CONFORMANCE

Shipping Weight
(lb)
19" RM
Operating
Temperature
Storage
Temperature
Altitude
Audible Noise
(1 meter from
surface)
Relative Humidity
Safety
EMC (EMS / EMI)
Warranty
Warranty policy

24(52.8) Power Module


None
70(154.0) Battery
Module

0 - 40 deg C / 32 ~ 104 deg F


-20 ~ 50 deg C / -4 ~ 122 deg F
3,500 meters max
< 55 dBA
0 ~ 95% humidity, non-condensing
UL 1778, CE
IEC 61000-4, FCC Part 15, CISPR 22
2 years
Warranty policy may vary depends on region

BACK

Copyright Powercom Co., Inc. 2005, All Rights Reserved.

http://www.pcmups.com.tw/product/vanguard6000.html (3 of 3)23/02/2006 13:53:33