You are on page 1of 184

TABLE OF CONTENTS

COMPOSITE DECK
AND NON-COMPOSITE DECK

FLOOR AND ROOF DECK APPLICATIONS

TABLE OF CONTENTS

General Benefits
of Composite Steel Deck
ASC Steel Deck has a firm understanding of the benefits
composite steel deck provides in building construction. The
strength of composite steel deck slab, relative to its light
weight, makes it the clear building material of choice when
compared to the alternative cast-in-place concrete approach.
Composite steel deck serves a dual function as it provides
both concrete reinforcement and a concrete form, while
serving as a working platform through the erection process.
Moreover, projects designed with a composite deck system
simply go up faster. The versatility, recyclable content,
structural performance, and ease of installation makes
steel deck the ideal building material for building owners,
architects, and engineers.

Aesthetic Value of Steel Deck


ASC Steel Deck provides steel deck panels that offer aesthetic value as an added benefit to the structural performance required
of building designs. When noise reduction is a necessity, ASC Steel Deck's Acustadek panels offer acoustical sound control
capabilities with aesthetic features that complement its use on exposed applications. Acustadek is generally preferred in high
noise areas such as airports, schools, gymnasiums, and concert halls.

Offering a Full Line of Steel Deck Products


ASC Steel Deck is the only steel deck manufacturer on the West Coast that offers a full line of light-gage structural and
deep deck products. From the standard 1 to 3 roof and composite floor deck, to concrete form deck, to long spanning
deep deck profiles, ASC Steel Decks extensive product offer meets the needs of the most complex conditions and demands
for structural performance and design. Most of our floor and roof deck products are offered in a variety of acoustical and
perforated options. For structural and acoustical performance information on these products, refer to the Acustadek section
of this catalog and our Roof Deck Catalog.

TABLE OF CONTENTS

Your Feedback is Welcome


Leading the way in steel deck innovation is dependent
upon your feedback. We invite architects, engineers
building owners, and all members of the building design
and construction industry to reach out to ASC Steel Deck
with any comments, suggestions, or needs for a profile we
currently do not offer

3W PANELS

ASC Steel Deck is leading the way in innovation with


ongoing testing of our profiles. As a result, our printed
catalogs may not contain/reflect the latest test results and
values of our products. For the most current load tables,
refer to our catalog online at www.ascsd.com.

GENERAL INFORMATION

Table of Contents

Email us at info@ascsd.com

5.0 N PANELS

1.1 Panel Features and Benefits . . . . . . . . . . . . . . . . . . . . . . 2-5


1.2 Product Offer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-8
1.3 Product Approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
1.4 Fire Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-19
1.5 Steel Deck Section Properties . . . . . . . . . . . . . . . . . . . 20-21
1.6 Web Crippling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22-23
1.7 Steel Deck at Concrete Form . . . . . . . . . . . . . . . . . . . . 24-25
1.8 Composite Deck-Slab Design . . . . . . . . . . . . . . . . . . . 26-28
1.9 Non-Composite Deck-Slab Design . . . . . . . . . . . . . . . . . 29
1.10 Penetrations and Openings . . . . . . . . . . . . . . . . . . . . . 30-33
1.11 Composite and Non-Composite
Diaphragm Shear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
1.12 Composite Deck-Slab Tables . . . . . . . . . . . . . . . . . . . 35-37
1.13 Support Fastening . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38-43
1.14 Side Seam Fastening . . . . . . . . . . . . . . . . . . . . . . . . . . 44-45
1.15 Edge Form . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46-47
1.16 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
1.17 Typical Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49-52
1.18 Composite Deck-Slab
Tables General Requirements . . . . . . . . . . . . . . . . . . . 53-55

5.1
5.2
5.3
5.4

NH-32 Panel Properties . . . . . . . . . . . . . . . . . . . . . . . . . 124


NHF-32 Panel Properties. . . . . . . . . . . . . . . . . . . . . . . . . 125
NHF-32 Shoring Tables . . . . . . . . . . . . . . . . . . . . . . 126-127
NH-32 Composite Deck-Slab . . . . . . . . . . . . . . . . . 128-138

6.0 C Panels

6.4 C1.4-32 Panel Properties . . . . . . . . . . . . . . . . . . . . . . . . 144


6.5 C1.4-32 Vertical Loads . . . . . . . . . . . . . . . . . . . . . . . . . . 145
6.6 C1.4-32 Shoring Tables . . . . . . . . . . . . . . . . . . . . . . 146-147

7.0 D Panels

2.1
2.2
2.3
2.4

7.7 6D-12 Panel Properties . . . . . . . . . . . . . . . . . . . . . . . . . . 158


7.8 6D-12 Vertical Loads . . . . . . . . . . . . . . . . . . . . . . . . . . . 159
7.9 6D-12 Shoring Tables . . . . . . . . . . . . . . . . . . . . . . . . 160-161

2WH-36 Panel Properties . . . . . . . . . . . . . . . . . . . . . . . . 82


2WHF-36 Panel Properties . . . . . . . . . . . . . . . . . . . . . . . . 83
2WHF-36 Shoring Tables . . . . . . . . . . . . . . . . . . . . . . . 84-85
2WH-36 Composite Deck-Slab . . . . . . . . . . . . . . . . . . 86-107

7.10 6DF-24 Panel Properties . . . . . . . . . . . . . . . . . . . . . . . . 162


7.11 6DF-24 Vertical Loads . . . . . . . . . . . . . . . . . . . . . . . 163-165
7.12 6DF-24 Shoring Tables . . . . . . . . . . . . . . . . . . . . . . . 166-167

4.1
4.2
4.3
4.4

7.16 7.5DF-24 Panel Properties . . . . . . . . . . . . . . . . . . . . . . . 172


7.17 7.5DF-24 Vertical Loads . . . . . . . . . . . . . . . . . . . . . . 173-175
7.18 7.5DF-24 Shoring Tables . . . . . . . . . . . . . . . . . . . . . 176-177

BH-36 Panel Properties . . . . . . . . . . . . . . . . . . . . . . . . . 108


BHF-36 Panel Properties . . . . . . . . . . . . . . . . . . . . . . . . 109
BHF-36 Shoring Tables . . . . . . . . . . . . . . . . . . . . . . 110-111
BH-36 Composite Deck-Slab . . . . . . . . . . . . . . . . . . 112-122

7.0 Acustadek

D PANEL

4.0 B PANELS

7.13 7.5D-12 Panel Properties . . . . . . . . . . . . . . . . . . . . . . . . 168


7.14 7.5D-12 Vertical Loads . . . . . . . . . . . . . . . . . . . . . . . . . . 169
7.15 7.5D-12 Shoring Tables . . . . . . . . . . . . . . . . . . . . . . 170-171

C PANELS

3.1
3.2
3.3
3.4

N PANELS

7.1 4.5D-12 Panel Properties . . . . . . . . . . . . . . . . . . . . . . . . 148


7.2 4.5D-12 Vertical Loads . . . . . . . . . . . . . . . . . . . . . . . . . . 149
7.3 4.5D-12 Shoring Tables . . . . . . . . . . . . . . . . . . . . . . 150-151

2.0 3W PANELS

3.0 2W PANELS

B PANELS

6.1 C0.9-32 Panel Properties . . . . . . . . . . . . . . . . . . . . . . . . 140


6.2 C0.9-32 Vertical Loads . . . . . . . . . . . . . . . . . . . . . . . . . . 141
6.3 C0.9-32 Shoring Tables . . . . . . . . . . . . . . . . . . . . . . 142-143

7.4 4.5DF-24 Panel Properties . . . . . . . . . . . . . . . . . . . . . . . 152


7.5 4.5DF-24 Vertical Loads . . . . . . . . . . . . . . . . . . . . . . 153-155
7.6 4.5DF-24 Shoring Tables . . . . . . . . . . . . . . . . . . . . . 156-157

3WH-36 Panel Properties . . . . . . . . . . . . . . . . . . . . . . . . 56


3WHF-36 Panel Properties . . . . . . . . . . . . . . . . . . . . . . . . 57
3WHF-36 Shoring Tables . . . . . . . . . . . . . . . . . . . . . . . 58-59
3WH-36 Composite Deck-Slab . . . . . . . . . . . . . . . . . . . 60-81

2W PANELS

1.0 GENERAL INFORMATION

8.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 178


8.2 Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 179

Metric Conversion Chart . . . . . . . . . . . . . . . . . . . . . . . 180


ACUSTADEK

Hilti is a registered trademark of Hilti Corp., LI- 9494 Schaan, Principality of Liechtenstein
PNEUTEK is a registered trademark of Pneutek, 17 Friars Drive Hudson, NH

www.ascsd.com

Composite and Non-Composite Deck Catalog May 2014

TABLE OF CONTENTS

1.1 Panel Features and Benefits

3WH-36 Hi Form

3WHF-36 Hi Form

Composite deck

Composite deck

3 inch deep, 36 inch coverage,

3 inch depth, 36 inch coverage,

10 foot to 14 foot Optimal Span Range

11 foot to 15 foot Optimal Span Range

No Acustadek Options

Pan Perforated Acustadek Option

Proven work horse for 10 to 14 foot span conditions

Aesthetic flat pan underside

Meets SDI 3x12 inch standard profile requirements

Meets SDI 3x12 inch standard profile requirements

Longer unshored spans than 2WH-36 and BH-36

Longer unshored spans than 2WHF-36 and BHF-36

2WH-36 Hi Form

2WHF-36 Hi Form

Composite deck

Composite deck

2 inch depth, 36 inch coverage

2 inch depth, 36 inch coverage

7 foot to 12 foot Optimal Span Range

9 foot to 13 foot Optimal Span Range

No Acustadek Option

Pan Perforated Acustadek Option

Least steel weight per square foot floor deck

Aesthetic flat pan underside

Meets SDI 2x12 inch standard profile requirements

Meets SDI 2x12 inch standard profile requirements

Reduced composite slab depth compared to 3WH-36


and NH-32

Reduced composite slab depth compared to 3WHF36 and NHF-32

BH-36 Hi Form

BHF-36 Hi Form

Composite deck

Composite deck

1 2 inch depth, 36 inch coverage

112 inch depth, 36 inch coverage,

7 foot to 10 foot Optimal Span Range

7 foot to 12 foot Optimal Span Range

No Acustadek Option

Pan Perforated Acustadek Option

Lowest composite deck-slab weight per square foot for


the specified concrete thickness above the deck

Aesthetic flat pan underside


Meets SDI 1.5WR standard profile requirements

Meets SDI 1.5WR (wide rib) standard profile


requirements

Composite and Non-Composite Deck Catalog May 2014

www.ascsd.com

TABLE OF CONTENTS

NHF-32 Hi Form

Composite deck

Composite deck

3 inch depth, 32 inch coverage

3 inch depth, 32 inch coverage

10 foot to 15 foot Optimal Span Range

11 foot to 15 foot Optimal Span Range

Pan Perforated Acustadek Option

Longest unshored spans

Aesthetic flat pan underside

Excellent alternate to SDI DR (deep rib) profile

Excellent alternate to SDI DR (deep rib) profile

Lower composite deck-slab weight than 3WH-36 for the


specified concrete thickness

8 inch on center low flute spacing to allow for bearing


wall studs to be at 16 inches oc

2W PANELS

No Acustadek Options

3W PANELS

NH-32 Hi Form

GENERAL INFORMATION

Panel Features and Benefits 1.1

8 inch on center low flute spacing to allow for bearing


wall studs to be at 16 inches oc

Non-composite deck

8 inch depth, 32 inch coverage,

138 inch depth, 32 inch coverage,

2 foot to 7 foot Span Range

4 foot to 9 foot Span Range

No Acustadek Options

No Acustadek Options

Good for short span conditions

Good for intermediate span conditions

For use when metal deck is used as a leave in place


form

For use when metal deck is used as a leave in place


form

C PANELS

Non-composite deck

N PANELS

C1.4-32

B PANELS

C0.9-32

D PANEL
ACUSTADEK

www.ascsd.com

Composite and Non-Composite Deck Catalog May 2014

TABLE OF CONTENTS

1.1 Panel Features and Benefits

4.5D12

4.5DF-24

Non-composite deck

Non-composite deck

4 2 inch depth, 12 inch coverage,

412 inch depth, 24 inch coverage

12 foot to 21 foot Span Range

15 foot to 21 foot Span Range

No Acustadek Option

Pan Perforated Acustadek Option

Allows for longest unshored spans

Aesthetic flat pan underside

For use when metal deck is used as a leave in place form

Allows for longer unshored span when metal deck is used


as a leave in place form
Longer unshored span than non-cellular profile
For use when metal deck is used as a leave in place form

6D-12

6DF-24

Non-composite deck

Non-composite deck

6 inch depth, 12 inch coverage,

6 inch depth, 24 inch coverage

14 foot to 25 foot Span Range

15 foot to 25 foot Span Range

No Acustadek Option

Pan Perforated Acustadek Option

Allows for longest unshored spans

Aesthetic flat pan underside

For use when metal deck is used as a leave in place form

Allows for longer unshored span when metal deck is used


as a leave in place form
Longer unshored span than non-cellular profile
For use when metal deck is used as a leave in place form

7.5D-12

7.5DF-24

Non-composite deck

Non-composite deck

7 2 inch depth, 12 inch coverage,

712 inch depth, 24 inch coverage

16 foot to 26 foot Span Range

16 foot to 27 foot Span Range

No Acustadek Option

Pan Perforated Acustadek Option

Allows for longest unshored spans

Aesthetic flat pan underside

For use when metal deck is used as a leave in place form

Allows for longer unshored span when metal deck is used


as a leave in place form
Longer unshored span than non-cellular profile
For use when metal deck is used as a leave in place form

Composite and Non-Composite Deck Catalog May 2014

www.ascsd.com

TABLE OF CONTENTS

Economical Selection Guide based on Recommended Unshored Spans


Product

10

12

14

16

18

20

22

24

26

GENERAL INFORMATION

Panel Features and Benefits 1.1

28
3W PANELS

C0.9-32
C1.4-32
BH-36

2W PANELS

2WH-36
3WH-36
NH-32

B PANELS

BHF-36
2WHF-36
3WHF-36
NHF-32

N PANELS

4.5D-12
6D-12
7.5D-12

C PANELS

4.5DF-24
6DF-24
7.5DF-24

D PANEL

Box outlines the range of unshored spans form the recommended unshored span range
Gray cells are based on 1 hour and 2 hour fire ratings with 20 and 18 gauge decks

ACUSTADEK

www.ascsd.com

Composite and Non-Composite Deck Catalog May 2014

TABLE OF CONTENTS

1.2 Product Offer

ASC Steel Deck offers a robust selection of products. Our


lightweight composite and non composite steel deck profiles
have depths that range from 78 to 712. Panel lengths range
from 3-6 to 45. Steel deck panels are supplied with both
galvanized and painted finishes to meet an array of project
finish requirements.
Product Description
To assist designers with specifying the correct steel deck
profile, see figure 1.2.3 which details how to specify the
intended product. Following these guidelines will help
to eliminate requests for information and change orders
due to insufficient product descriptions in the plans and
specifications. Designers can be assured that the product
delivered is the product intended. Simply specify the gage,
panel profile, panel coverage, metallic/paint coating, and
any modifiers appropriate for the desired product
Deck Panel Lengths
All ASC Steel Deck products are manufactured to the specified
length for the project. The following table summarizes the
minimum and maximum lengths that can be manufactured
for each profile.
Figure 1.2.1: MANUFACTURED PANEL LENGTHS
Profile

Factory Cut Length

Non-cellular

Cellular

Minimum

Maximum

BH-36, NH-32,
2WH-36, 3WH-36

3-6

45-0

C0.9-32 &
C1.4-32

4-0

45-0

4.5D-12, 6D-12,
7.5D-12

6-0

32-0

BHF-36, NHF32, 2WHF-36,


3WHF-36

5-0

40-0

4.5DF-24,
6DF-24,
7.5DF-24

6-0

32-0

Tolerances
ASC Steel Deck manufactures to industry standard tolerances.
The tolerances are summarized as follows.
Figure 1.2.2: PANEL TOLERANCES
Length

1/2

Coverage Width

-3/8 +3/4

Sweep

1/4 in 10 length

Square

1/8 per foot width

Finish Options
ASC Steel Deck offers several finish options that are
appropriate for a variety of applications. Our standard G60

galvanized finish is suitable for most applications, offering


excellent corrosion protection and compatibility with fire
proofing when used in UL fire rated assemblies. We also
offer Prime Shield, an economical prime paint system
over bare cold rolled steel. Prime Shield offers the steel
limited interim protection from rusting during transport
and erection before the concrete topping is applied. Prime
Shield should not be used in high humidity or corrosive
environments. Prime paint over galvanized steel deck can
also be specified to obtain the benefit of the corrosion
protection of galvanized steel deck with a factory applied
prime paint substrate.
Galvanized
ASC Steel Deck offers steel deck products that are
galvanized in accordance with ASTM A653. The standard
galvanized coating is G60 (0.6 ounce per square foot).
G-90 (0.9 ounce per square foot) is recommended for high
humidity and corrosive conditions. G-40 (0.4 ounce per
square foot) may also be specified for greater economy.
Heavier galvanized finishes than G-90 can be specified
for more severe environmental conditions and exposures.
Inquire for product availability and minimum order sizes
for G-40 or galvanizing heavier than G-90.
All ASC Steel Deck galvanized decks are manufactured
from chemically treated steel coil in accordance with ASTM
A653. Chemical treatment is often referred to as passivation.
The chemical treatment protects the galvanized steel from
developing white rust during storage and transport of both
coil and finished product. Some field-applied paint systems
may not be compatible with the chemical treatment. The paint
manufacture should be consulted to determine how the deck
should be prepared prior to painting. ASC Steel Deck is not
responsible for the adhesion of field applied primers and paints.
Galvanized with Prime Paint
ASC Steel Deck offers all of its standard galvanized options
with factory applied prime paint on the underside of the deck.
The prime paint is available in standard gray and white is also
available for some specified prime paints. The 0.3mil waterbased acrylic primer has been specially developed to provide
superior adhesion to the galvanized steel deck. The gray primer
is suitable for use in many UL fire rated assemblies. The primer
is an impermanent interim coating that is intended to have
finish paint applied after the deck is installed. The galvanized
with prime paint option may eliminate the need for any special
surface preparation for field applied paint applications which is
often a requirement for chemically treated, and bare galvanized
steel deck panels. ASC Steel Deck is not responsible for the
adhesion of paint systems applied in the field.
Cellular deck is offered with galvanized steel pan or prime
paint over galvanized steel pan. This 0.3mil gray primer
is applied to the underside of the pan prior to welding the
cellular deck beam to the pan with resistance welds. This
process leaves burn marks on the pan that may require

Composite and Non-Composite Deck Catalog May 2014

www.ascsd.com

TABLE OF CONTENTS
GENERAL INFORMATION

Product Offer 1.2

Specify
Required
Gage(s) of
Deck

See
Panel and
Coverage
List

See
Panel and
Coverage
List

Omit: Standard
standing seam
side lap interlock

20
191

DG: DeltaGrip
standing seam
side lap interlock

182
162

Omit: Nonembossed
smooth deck
(Roof)
H: Embossed
HiForm
composite
deck (Floor)

Omit: Standard
profiles non-cellular
with standard
standing seam
side lap interlock

N: Nestable side lap

20/20

S: Standing seam
screwable side lap
(2WHS-36 only)

20/18

18/18

16/183
16/163
1

D is only
available
in these
gages

Non-Composite

Not Applicable

fie
di

pa

Mo

de

Sp

ec

ial

Si

Si

tto
m
Bo

To
p

rs

t
in

t
in
Pa
de

at
in
Co
ic
ta
ll
Note: Inquire for other
galvanized coating
weights

G60/G60: Galvanized
G90/G90: Galvanized

NS: No Swage,
B-36 only

Gray: Primer over galvanized


(Available for cellular deck)
Weldable Primer: (Only
available for cellular decks
span underside only)
White: Primer over
galvanized

A: Acustadek pan
perforation for use
with cellular profile
modifier, F, only

Roof

Coverage

36 inches

32 inches

2W

36 inches

3W

36 inches

Not Applicable

32 inches

C1.4-32

CP-32

32 inches

4.5D

12 inches

4.5DF

24 inches

6D

12 inches

6DF

24 inches

7.5D

12 inches

7.5DF

24 inches

DF is only
available
in these
gages

Note:
1. ASC Steel Deck may substitute ASTM A653 G01 galvanized steel deck for ASTM A1008.

Cellular Deck
Cellular deck is a good choice when a flat appearance on
the underside of the steel deck is desired. Cellular deck is
manufactured from a top fluted section of steel deck referred to
as the beam, and a flat bottom section referred to as the pan.
The beam and pan are welded together using resistance welds in
accordance with UL 209. There is one row of resistance welds
in each low flute of the beam. The male and female side seam
interlock is formed on the edges of the pan.
Cellular deck beam and pan may be manufactured out of the
same gage or out of different gages. The following shows how
to correctly specify the desired beam and pan gage combination.
Specify Cellular Deck Gage xx/yy
The first (xx) is the gage of the beam (top fluted section)
The second number (yy) is the gage of the pan (the
bottom flat section with the side seam)

Composite and Non-Composite Deck Catalog May 2014

ACUSTADEK

Prime Shield
Prime Shield is prime painted cold-rolled, ASTM 10081, steel
deck. The standard gray primer is applied to the underside of
the steel deck leaving the top side bare for concrete adhesion.

The formation of light rust on the top side of the deck prior
to concrete placement is common, and does not adversely
impact the deck or composite deck-slab assembly. This primer
is suitable for use in many UL fire rated assemblies. The prime
paint is intended to be an impermanent interim coating to
protect the bare cold-rolled steel, for a short period, from
ordinary atmospheric conditions prior to weathertighting the
building. Prime Shield should receive a finish paint system
if left exposed in the interior of a building. This 0.3mil waterbased acrylic primer provides a good base for most fieldapplied paint systems. ASC Steel Deck is not responsible for the
adhesion of paint systems applied in the field.

D PANEL

additional prime paint in the field prior to a finish paint system


being applied. Touching up the burn marks is generally much
more cost effective than preparing an unpainted, chemically
treated surface for the application of a field primer. The prime
painted galvanized pan provides a good substrate for the
application for most field-applied paint systems. ASC Steel
Deck is not responsible for the adhesion of paint systems
applied in the field.

www.ascsd.com

Me

AT: Acustadek total


perforation for use
with non-cellular
standard or DeltaGrip,
DG, profiles only

C0.9-32

Not Applicable

g(
s)

er
od
na

G90: Galvanized

Omit: None

Prime Shield: Gray primer


on bare steel or GO1
galvanized

C PANELS

2W & 3W
only on
special
order

AW: Acustadek web


perforation for use
with non-cellular
standard or DeltaGrip,
DG, profiles only

G60: Galvanized

None: No primer

N PANELS

16/20

Omit: Bare NonGalvanized Steel

DECK PROFILE
AND COVERAGE LIST

18/163

Gray / Gray

Omit: Standard
profiles without
Acustadek
perforations

V: Venting
(non-cellular only)

20/16
18/20

G60/G60

B PANELS

F: Cellular

142

2W PANELS

22
211

ifi

36

Op
tio

lC
ne
Pa

nfi
Co

lM

er
ov

n
tio
ra

gu

rm
Fo
Hi

ag

Mo

r
di
Mo

ro
lP
ne
Pa

Gr
ip
lta
De

DG

fie

e
fil

di
Mo

e(
s)
Ga
g

18/20

3W PANELS

fie

di

fie

Figure 1.2.3: PRODUCT OFFER DESCRIPTION

TABLE OF CONTENTS

1.2 Product Offer

Venting
Some materials in building assemblies, including composite or
non composite steel decks, may require the deck to be vented.
Venting does not impact structural performance of steel deck and
has no bearing on fire ratings. Venting does not influence the
rate at which the concrete moisture content drops during curing
of the slab on the deck
Some materials that are bonded by adhesives to the surface
of concrete slab on the composite deck may be sensitive to
the moisture content of the concrete. Venting is sometimes
specified, with the intent of creating a route for moisture to
escape from the bottom of the concrete through the steel deck
vents. Research performed by the Expanded Shale Clay and
Slate Institute, however, demonstrated that venting has no
bearing on how quickly the moisture content of concrete on steel
deck decreases (concrete drying time)2.
Deck should not be specified as vented when it is not required
by another materials' performance specification. The drawback
of venting deck is that when concrete is poured, the slurry
drips through the vent tabs creating debris on the surface
below. Cleaning up the slurry or protecting the surfaces
underneath with plastic sheets adds cost to the project without
providing any added value to the owner when venting is not
required. The requirement for venting the deck should be
clearly indicated in the specifications and be clearly stated in
the deck schedule on the structural drawings to avoid confusion.
Note:
2. Craig, Peter A. (2011) Lightweight Concrete Drying Study. Chicago, IL: Expanded Shale Clay
and Slate Institute

Figure 1.2.5: 3WH-36V WITH VENTING


(Pictured from topside)

Die Set Ends (Swage)


Die set ends allow for deck panels to be end lapped. This is
not a common practice for composite deck but is common
for roof decks. The die set swages the top flange and webs of
the steel deck which allows the top sheet of end lapped deck
to nest tightly over the bottom sheet. When deck is not die
set, the installer may have to hammer the deck to get the ends
to nest together tightly to ensure good quality connections.
The die set ends are standard for BH-36 and NH-32 profiles.
BH-36 is optionally available without die set ends. 2WH-36,
3WH-36, Deep Deck, and cellular profiles are not end lapped
and do not have die set ends. Figure 1.2.6 shows a die-set end
on NH-32 deck.

Vent Tabs
All ASC Steel Deck composite decks including; B, N, 2W, and
3W deck, have upward protruding vent tabs that are factory
punched in the low flutes of the steel deck when venting is
specified. (See Figures 1.2.4, and 1.2.5) C0.9-32 and C1.432 do not have a venting option. CP-32 roof deck may be used
as an alternate to C1.4-32 when venting is required. The CP-32
has embossments in the side lap that holds the side lap
open creating a vent at each side.

Figure 1.2.6: N-32 WITH DIE-SET (Swage)

Die set ends affect detailing and layout of the steel


deck. Deck is spread in the direction of the male
leg of the side seam. This allows the next sheets
female side seam to drop over the male side seam.
The die set is on the left side relative to the direction
of spreading deck. The next adjacent run of deck will
be on the left side of the deck relative to the spreading
direction to nest over the dies set ends. (See figure 1.2.7)
Figure 1.2.4: BH-36V WITH VENTING
(Pictured from underside)

Composite and Non-Composite Deck Catalog May 2014

www.ascsd.com

TABLE OF CONTENTS
GENERAL INFORMATION

Product Approvals 1.3

MALE SIDE SEAM

3W PANELS

2nd RUN

2W PANELS

1st RUN OF DECK

DIE SET END

Figure 1.2.9: TOPSIDE HANDLING MARKS

FEMALE SIDE SEAM


END LAP
Figure 1.2.7: DECK LAYOUT

Composite and Non-Composite Deck Catalog May 2014

ACUSTADEK

www.ascsd.com

D PANEL

Figure 1.2.8: UNDERSIDE HANDLING MARKS

The Fire Ratings table (See figure 1.4.1) offers a quick


reference summary of design numbers, fire ratings, deck type,
SFRM Spray Applied Fire Resistive material listings and more.
The details of the each design assembly are listed on UL
Online Certification Directory www.ul.com.

C PANELS

Underwriters Laboratories UL-Fire Ratings


ASC Steel Deck products that bare the UL approved mark have
been investigated for fire resistance. Underwriters Laboratories
is an independent, product safety testing and certification
organization. ASC Steel Deck has been evaluated for fire
resistance per UL 263 Fire Tests of Building Construction and
Materials. See UL directory for fire rated assemblies.

N PANELS

IAPMO-ES
ASC Steel Deck's composite and non-composite steel deck
panels are independently evaluated for conformance with the
IBC by IAPMO-ES. IAPMO-ES is accredited by the American
Standards Institute (ANSI) per ISO/IEC Guide 65 General
Requirements for Bodies Operating Product Certification
Systems. LA City Research Reports (LARR) for ASC composite
and non-composite steel decks are derived from IAPMO-ES
reports. The technical evaluation for conformance with the
IBC is made available to code officials, contractors, specifiers,
architects, engineers, and others. IAMPO-ES reports provide
evidence that ASC Steel Deck products meet the most
rigorous standards and are compliant under current code
requirements.

B PANELS

Exposed Deck
ASC Steel Deck roof and floor deck products are designed
to be structural components for steel framed structures. As
part of the normal manufacturing, handling, and transport
procedures, it is common for the panel bundles to exhibit
some degree of incidental scratching and denting. The
surface defects are typically superficial and do not impact
the structural capacity of the deck. On projects where the
deck will be exposed to view after installation, it may be
desirable to minimize the occurrence of these marks. In
these cases, it is important for the designer specifying and
the customer or contractor ordering the deck to request that
the product be manufactured, handled, and transported
for "EXPOSED" installation. This will result in modified
handling and loading procedures designed to minimize
(not eliminate) typical scratching and denting. Figure 1.2.8
and 1.2.9 shows typical handling marks from forklifts or
dunnage.

ASC Steel Deck conducts extensive test and engineering


programs with independent testing labs to ensure that our
products comply with the stringent criteria of todays building
codes. The structural performance of our composite and
non-composite steel deck products have been verified and
approved by reputable evaluation agencies, such as the
International Association of Plumbing and Mechanics Officials
Uniform Evaluation Services (IAPMO-ES), Los Angeles City
Research Reports (LARR), and Underwriters Laboratory (UL).

TABLE OF CONTENTS

1.4 Fire Ratings

Figure 1.4.1: ASC STEEL DECK- UNDERWRITERS LABORATORIES (UL) FIRE RESISTANCE

UL Design
Number

Unrestrained
Assembly
Rating8

Minimum Beam or Joist

D216

W8x15, 10J3, 12K1, 20LH


with a minium of 13 lbs per foot weight

1, 1-1/2, 2, 3

D303

W8x28

1, 1-1/2, 2

hr

Support Type

Fire Proofing
On

Minimum Concrete
Reinforcing

Beam Deck

6x6 W1.4xW1.4

none
(ceiling
system
below)

none

6x6 10x10 SWG

Mineral
fiber
board

Mineral
fiber
board

none

D502 W8x28, 20" Joist Girders at 20plf, 12K1, LH Series joists

1-1/2, 2

6x6 W1.4xW1.4

none
(ceiling
system
below)

D703

W8x20

1, 1-1/2

6x6 W2.9xW2.9

SFRM

SFRM

D708

W10x17

1-1/2,3

6x6 W2.9xW2.9

SFRM

SFRM

D712

W8x24

1-1/2, 2

6x6, 10x10 SWG

SFRM

SFRM

D722

W6x12

1, 1-1/2, 2, 3

6x6 W1.4xW1.4

SFRM

SFRM

D739

W8x28, W6x12,OWSJ, Cast in place concrete beams

1, 1-1/2, 2, 3, 4

6x6 W2.9xW2.9, Synthetic fibers

SFRM

SFRM

D740

W10x15

6x6 10x10 SWG

SFRM

SFRM

D743

W8x20, W8x28, W8x15, Cast in place concrete beams

1, 1-1/2, 2, 3

6x6 W1.4xW1.4

SFRM

SFRM

D750

W8x21

1-1/2, 2

6x6 W1.4xW1.4

SFRM

SFRM

D754

W8x28

1-1/2, 2

6x6 W1.4xW1.4

SFRM

SFRM

D755

W8x24, W8x28, 10H3, 12J6

1, 1-1/2, 2, 3

6x6 W1.4xW1.4

SFRM

SFRM

10

Composite and Non-Composite Deck Catalog May 2014

www.ascsd.com

TABLE OF CONTENTS

Figure 1.4.1: ASC STEEL DECK- UNDERWRITERS LABORATORIES (UL) FIRE RESISTANCE

NH-32

NHN-32

NHF-32

2HW-36

2HWF-36

3HW-36

3HWF-36

UL Design
Number

BHF-36

114-120 LW

2 1/2

147-153 NW

D502

1, 1-1/2, 2, 3

2 1/2

142-148 NW
105 LW

D703

2 1/2

145-151 NW
109-115 LW

D708

1, 1-1/2, 2

2 1/2

147-153 NW
110 LW

D712

1, 1-1/2, 2, 3

2 1/2

142-148 NW
112 LW

D722

1, 1-1/2, 2, 3, 4

2 1/2

142-148 NW
102-120 LW
(110 LW
with joists)

D739

2 1/2

147-153 NW

1, 1-1/2, 2, 3

147-153 NW
107-113 LW

2 1/2

142-148 NW
105-111 LW

3, 4

3 1/4

115-121 LW

2, 3

2 1/2

147-153 NW
109-115 LW

3 1/2

147-153 NW

1 1/2

147-153 NW

4 1/2

147-153 NW

5 1/4

147-153 NW

3/4 or 1

2 1/2

107-113 LW

1 1/2

107-113 LW

3 1/4

107-113 LW

3 1/4

107-116 LW

4 3/16

107-113 LW

2 5/8

107-120 LW

3 1/2

114-120 LW

4 7/16

1-1/2, 2

C PANELS
D PANEL

D740

D750
D754

D743

ACUSTADEK

www.ascsd.com

D303

N PANELS

B PANELS

147-153 NW
107-113 LW

C1.4-32

1, 1-1/2, 2, 3

varies
depending
on acoustic
material, see
UL listing

2W PANELS

BH-3514

D216

BHN-36

BH-36

Note

Hi Form 3

3W PANELS

Concrete
Restrained
Assembly
Unit
Rating
Thickness
Weight
hr
in
pcf

GENERAL INFORMATION

Fire Ratings 1.4

D755

Composite and Non-Composite Deck Catalog May 2014

11

TABLE OF CONTENTS

1.4 Fire Ratings

Figure 1.4.1: ASC STEEL DECK- UNDERWRITERS LABORATORIES (UL) FIRE RESISTANCE

Support Type

Fire Proofing
On

Minimum Concrete
Reinforcing

Beam Deck

UL Design
Number

Unrestrained
Assembly
Rating8

Minimum Beam or Joist

D759

W8x28, 12K1, 12" Deep OWSJ at 71.plf

1, 1-1/2, 2, 3

6x6 W1.4xW1.4 with beams,


6x6 W2.9xW2.9 with joists, Fiber
reinforcement

SFRM

SFRM

D760

W8x28, OWSJ

1, 1-1/2, 2, 3, 4

6x6 W1.4xW1.4

SFRM

SFRM

D764

W8x28, OWSJ

6x6, 6x6 SWG

SFRM

SFRM

D767

W8x28, W6x12,OWSJ, Cast in place concrete beams

1, 1-1/2, 2, 3, 4

6x6 W1.4xW1.4 with beams, 6x6


W2.9xW2.9 with OWSJ

SFRM

SFRM

D768

W10x17

1, 1-1/2, 3

6x6 W2.9xW2.9

SFRM

SFRM

D775

W8x21

1-1/2, 2

6x6 W1.4xW1.4

SFRM

SFRM

D779

W8x28, 8K1

1, 1-1/2, 2, 3, 4

6x6 W1.4xW1.4, Synthetic fibers,


Steel fibers

SFRM

SFRM

D782

W8x28, 10" Deep OWSJ

1, 1-1/2, 2, 3, 4

6x6 W1.4xW1.4

SFRM

SFRM

D787

W8x28, W6x12, Concrete beam, OWSJ

1, 1-1/2, 2, 3, 4

6x6 W1.4xW1.4,

SFRM

SFRM

D788

W8x28, 10K1

1, 1-1/2, 2, 3, 4

6x6 8x8 SWG

SFRM

SFRM

D794

W8x28, OWSJ

6x6 6x6 SWG

SFRM

SFRM

D795

W8x28, OWSJ

1, 1-1/2, 2, 3

6x6 W1.4xW1.4 with beams, 6x6


W2.9xW2.9 with OWSJ

SFRM

SFRM

D825

W8x17

1, 1-1/2, 2

6x6 W1.4xW1.4

SFRM

SFRM

D826

W8x20

6x6 W1.4xW1.4

D832

W8x20, W8x28

1, 1-1/2, 2, 3

6x6 W1.4xW1.4

SFRM

SFRM

D833

W10x25

2, 3

WWF Optional

SFRM

SFRM

D840

W8x28

6x6 10x10 SWG

SFRM

SFRM

D858

W10x25, Concrete beam

1, 1-1/2, 2, 3, 4

6x6 W1.4xW1.4

SFRM

SFRM

D859

W8x10

1, 1-1/2, 2, 3

6x6 W1.4xW1.4

SFRM

SFRM

12

hr

Composite and Non-Composite Deck Catalog May 2014

SFRM

www.ascsd.com

TABLE OF CONTENTS

NH-32

NHN-32

NHF-32

2HW-36

2HWF-36

3HW-36

3HWF-36

D767

D768

D775

142-148 NW
102-120 LW

D779

3 1/4

115-121 LW

D782

1, 1-1/2, 2, 3, 4

2 1/2

142-148 NW
102-120 LW
(110 LW
with joists)

1, 1-1/2, 2, 3, 4

2 1/2

NW
LW

D788

2 1/2

147-153 NW
117 LW

D794

1, 1-1/2, 2, 3

2 1/2

147-153 NW
109-115 LW

D795

2 1/2

147-153 NW
105-111 LW

D825

3 1/4

108-114 LW

D826

1, 1-1/2, 2, 3

2 1/2

147-153 NW
109-115 LW

D832

2, 3

2 1/2

147-153 NW
107-115 LW

D833

3 1/4

107-113 LW

1, 1-1/2, 2, 3, 4

2 1/2

147-153 NW
108-115 LW

D858

1, 1-1/2, 2, 3

142-148 NW
108-115 LW

D859

147-153 NW
109-115 LW

1-1/2, 2, 3, 4

2 1/2

144-150 NW
107-113 LW

2 1/2

117 LW

1, 1-1/2, 2, 3, 4

2 1/2

142-148 NW
102-120 LW
(110 LW
with joists)

2 1/2

145 NW
109-115 LW

2 1/2

142-148 NW
105-111 LW

1, 1-1/2, 2, 3, 4

2 1/2

1, 1-1/2, 2, 3, 4

D759
D760

D764

D787

C PANELS
D PANEL

D840

N PANELS
ACUSTADEK

www.ascsd.com

C1.4-32

2 1/2

B PANELS

1, 1-1/2, 2, 3

2W PANELS

BH-3514

BHN-36

BH-36

BHF-36

Note

Hi Form 3

3W PANELS

Concrete
Restrained
Assembly
Unit
Rating
Thickness
Weight
hr
in
pcf

UL Design
Number

Figure 1.4.1: ASC STEEL DECK- UNDERWRITERS LABORATORIES (UL) FIRE RESISTANCE

GENERAL INFORMATION

Fire Ratings 1.4

Composite and Non-Composite Deck Catalog May 2014

13

TABLE OF CONTENTS

1.4 Fire Ratings

Figure 1.4.1: ASC STEEL DECK- UNDERWRITERS LABORATORIES (UL) FIRE RESISTANCE

Support Type

Fire Proofing
On

Minimum Concrete
Reinforcing

Beam Deck

UL Design
Number

Unrestrained
Assembly
Rating8

Minimum Beam or Joist

D861

W8x15, W10x25

1, 1-1/2, 2, 3

6x6 W1.4xW1.4

SFRM

SFRM

D862

W8x21

6x6 W1.4xW1.4

SFRM

SFRM

D867

W8x18

1-1/2, 2

6x6 6x6 SWG

SFRM

SFRM

D871

W8x21, Concrete beam

1, 1-1/2, 2, 3

6x6 W1.4xW1.4

SFRM

SFRM

D875

W8x20

1, 1-1/2, 2, 3

6x6 W1.4xW1.4

SFRM

SFRM

D877

W8x17

1, 1-1/2, 2

6x6 W1.4xW1.4

SFRM

SFRM

D878

W8x20

6x6 W1.4xW1.4

SFRM

SFRM

D883

W8x24, W8x,28

1, 1-1/2, 2, 3

6x6 W1.4xW1.4

SFRM

SFRM

D884

W10x25

2, 3

WWF Optional

SFRM

SFRM

D888

W8x28

6x6 10x10 SWG

SFRM

None

D891

W10x25, Concrete beam

1, 1-1/2, 2, 3, 4

6x6 W1.4xW1.4

SFRM

SFRM

D892

W8x25, W10x25

1-1/2, 2

6x6 W1.4xW1.4

SFRM

SFRM

D893

W8x21

6x6 W1.4xW1.4

SFRM

SFRM

D898

W8x21, Concret beam

1, 1-1/2, 2, 3, 4

6x6 W1.4xW1.4

SFRM

SFRM

D902

W12x14, W8x28, W8x24, W6x21, 8K1, 12K5, OWSJ

1, 1-1/2, 2, 3

D923

W8x28

1-1/2

D925

W8x28, W8x16, 8K1 OWSJ

1, 1-1/2, 2, 3

D931

6x6 6x6 SWG, Fiber reinfrorcement

SFRM

none

W8x28

D957

W12x14,W8x28, W8x24, W6x12, OWSJ

1, 1-1/2, 2, 3

D975

W8x28, W8x24, W6x12

1, 1-1/2, 2, 3

14

hr

Composite and Non-Composite Deck Catalog May 2014

www.ascsd.com

TABLE OF CONTENTS

2HW-36

2HWF-36

3HW-36

3HWF-36

Note

NHF-32

C1.4-32

D861
D862

D871

D867

1, 1-1/2, 2, 3

142-148 NW
108-115 LW

D875

2 1/2

147-153 NW
105-111 LW

D877

3 1/4

108-114 LW

D878

1, 1-1/2, 2, 3

2 1/2

147-153 NW
109-115 LW

D883

2, 3

2 1/2

147-153 NW
107-115 LW

D884

3 1/4

107-113 LW

3 1/4

107-116 LW

3 1/2

107-120 LW

1, 1-1/2, 2, 3, 4

2 1/2

147-153 NW
108-115 LW

2 1/2

D891

137-150 NW
107-115 LW

D892

2 1/2

109-115 LW

1, 1-1/2, 2, 3, 4

2 1/2

147-153 NW
108-115 LW

1
1-1/2
2

3 1/2
4
4 1/2

147-153 NW
147-153 NW
147-153 NW

5 1/4

147-153 NW

1
1-1/2
2
2

2 1/2
3
3 1/4
3 1/4

107-113 LW
107-113 LW
107-113 LW
107-116 LW

4 3/16

107-113 LW

1
2
3

2 5/8
3 1/2
4 7/16

107-120 LW
114-120 LW
114-120 LW

D893

D898
D902
D923
D925
D931
D957
D975

Composite and Non-Composite Deck Catalog May 2014

15

ACUSTADEK

D PANEL

www.ascsd.com

D888

C PANELS

147-153 NW
108-115 LW

N PANELS

2 1/2

B PANELS

1, 1-1/2, 2, 3

2W PANELS

144-150 NW
107-113 LW

NHN-32

99-105 LW

NH-32

2 1/2

BHF-36

BH-3514

137-150 NW
107-115 LW

BHN-36

2 1/2

BH-36

1, 1-1/2, 2, 3

Hi Form 3

3W PANELS

Concrete
Restrained
Assembly
Unit
Rating
Thickness
Weight
hr
in
pcf

UL Design
Number

Figure 1.4.1: ASC STEEL DECK- UNDERWRITERS LABORATORIES (UL) FIRE RESISTANCE

GENERAL INFORMATION

Fire Ratings 1.4

TABLE OF CONTENTS

1.4 Fire Ratings

UL Design
Number

Figure 1.4.1: ASC STEEL DECK- UNDERWRITERS LABORATORIES (UL) FIRE RESISTANCE

Minimum Beam or Joist

D907
D914

W8x17, W8x28
W8x28

D916

W8x28, OWSJ

D922

W8x28, OWSJ

D927

W8x28, OWSJ

D943

W8x28, OWSJ

Unrestrained
Assembly
Rating8
hr

1, 2
1

Support Type

Fire Proofing
On

Minimum Concrete
Reinforcing

Beam Deck

6x6 W1.4xW1.4
6x6 W1.4xW1.4

SFRM
SFRM

none
none

6x6 10x10 SWG

SFRM

none

1-1/2

6x6 W1.4xW1.4

SFRM

none

1-1/2

6x6 W1.4xW1.4

SFRM

none

1-1/2

6x6 W1.4xW1.4

SFRM

none

Synthetic fibers, negative


reinforcing steel

SFRM

none

1, 1-1/2, 2, 3

1-1/2

1, 1-1/2, 2, 3

D949

W8x28

D918

W8x20

D919

W8x28

D968

W8x28

D920

W8x28

1,

D924

W8x28

1-1/2,
2,
3

16

Composite and Non-Composite Deck Catalog May 2014

www.ascsd.com

TABLE OF CONTENTS

150-156 NW
150-156 NW
150-156 NW
150-156 NW

1
2
3

2 1/2
3 1/4
4 3/16

107-113 LW
107-113 LW
107-113 LW

2
3

3 1/2
4 7/16

107-120 LW
114-120 LW

1
1-1/2
2
3

3 1/2
4
4 1/2
5 1/4

147-153 NW
147-153 NW
147-153 NW
147-153 NW

1
1-1/2
2
3

2 1/2
3
3 1/4
4 3/16

107-113 LW
107-113 LW
107-116 LW
107-113 LW

2
3

3 1/2
4 7/16

114-120 LW
114-120 LW

3 1/4

110-120 LW

2
2

4 1/8
4 3/8

142-148 NW4
142-148 NW5

2
3
3
3

3 1/8
5
5 3/8
4

105-111 LW
105-111 LW4
105-111 LW5
105-111 LW

www.ascsd.com

Note

3HWF-36

3HW-36

2HWF-36

C1.4-32

2HW-36

3 1/2
4
4 1/2
5 1/4

NHF-32

1
1-1/2
2
3

NHN-32

107-120 LW
114-120 LW
114-120 LW

NH-32

2 5/8
3 1/2
4 7/16

BHF-36

1
2
3

BH-3514

107-113 LW
107-113 LW
107-113 LW
107-116 LW
107-113 LW

BHN-36

2 1/2
3
3 1/4
3 1/4
4 3/16

BH-36

3/4 or 1
1-1/2
2
2
3

D907
D914
D916
D922
8

D927
D943
D949

D918

D919
8

D968
8

D920

4, 5, 8

D924

Composite and Non-Composite Deck Catalog May 2014

ACUSTADEK

147-153 NW
147-153 NW
147-153 NW
147-153 NW

D PANEL

3 1/2
4
4 1/2
5 1/4

C PANELS

1
1-1/2
2
3

N PANELS

110 LW
110 LW

B PANELS

3 1/4
2 1/2

2W PANELS

2
3/4, 1

Hi Form 3

3W PANELS

Concrete
Restrained
Assembly
Unit
Rating
Thickness
Weight
hr
in
pcf

UL Design
Number

Figure 1.4.1: ASC STEEL DECK- UNDERWRITERS LABORATORIES (UL) FIRE RESISTANCE

GENERAL INFORMATION

Fire Ratings 1.4

17

TABLE OF CONTENTS

1.4 Fire Ratings

UL Design
Number

Figure 1.4.1: ASC STEEL DECK- UNDERWRITERS LABORATORIES (UL) FIRE RESISTANCE

Minimum Beam or Joist

Unrestrained
Assembly
Rating8
hr

Support Type

Fire Proofing
On

Minimum Concrete
Reinforcing

Beam Deck

1,

D929

W8x28

1-1/2,
2,

6x6 10x10 SWG

SFRM

none

6x6 W1.4xW1.4
Fiber - Ultra Fiber 500
6x6 10x10 SWG
6x6 8x8 SWG
6x6 8x8 SWG

SFRM

none
none
none
none
none

D967
D973
D974
D976
D977

W8x28
W8x28
W8x28
W8x28 OWSJ
W8x28, OWSJ

1
2
1-1/2
1, 1-1/2, 2
1, 1-1/2, 2

Table Notes:
1. See UL Directory for complete assembly requirements
2. SFRM = Spray-Applied Fire Resistive Material
3. ASC Steel Deck may be used as blend deck with other manufacturers
electrified cellular deck or trench.
4. Carbonate Aggregate
5. Siliceous Aggregate
6. Buckeye Technologies Inc. Ultra Fiber 500
7. Syntheon Inc Elemix XE additive
8. For restrained fire ratings see UL listng for additional requirements

18

Composite and Non-Composite Deck Catalog May 2014

www.ascsd.com

TABLE OF CONTENTS

Figure 1.4.1: ASC STEEL DECK- UNDERWRITERS LABORATORIES (UL) FIRE RESISTANCE

UL Design
Number

Note

3HWF-36

3HW-36

C1.4-32

2HWF-36

110 LW
142-148 NW6
114-120 NW7
111 NW7
106.5 LW7

2HW-36

2 1/2
2 1/2
4 1/2
3 1/2
3 1/2

NHF-32

3/4, 1
2
1-3
1, 1-1/2, 2
1, 1-1/2, 2

NHN-32

107-120 LW
107-120 LW
114-120 LW
114-120 LW

NH-32

2 5/8
3 1/2
3 1/2
4 7/16

BHF-36

1
2
2
3

BH-3514

107-113 LW
107-113 LW
107-113 LW
107-116 LW
107-113 LW

BHN-36

2 1/2
3
3 1/4
3 1/4
4 3/16

BH-36

3/4 or 1
1-1/2
2
2
3

D929

8
6, 8
7, 8
7, 8
7, 8

D967
D973
D974
D976
D977

N PANELS

NW
NW
NW
NW

B PANELS

3 1/2
4
4 1/2
5 1/4

2W PANELS

1
1-1/2
2
3

Hi Form 3

3W PANELS

Concrete
Restrained
Assembly
Unit
Rating
Thickness
Weight
hr
in
pcf

GENERAL INFORMATION

Fire Ratings 1.4

C PANELS
D PANEL
ACUSTADEK

www.ascsd.com

Composite and Non-Composite Deck Catalog May 2014

19

TABLE OF CONTENTS

1.5 Steel Deck Section Properties

Section Properties
All of ASC Steel Deck's section properties are calculated
in accordance with the American Iron and Steel Institute
Specification for the Design of Cold-Formed Steel Structural
Members, AISI S100-2007, Section B. Section properties
can be used to develop the bending capacity of the steel
deck for out-of-plane loads, which are typically defined by
gravity for composite decks carrying construction and fluid
concrete loads.
The section properties for steel floor deck, like other
cold-formed steel members such as Cee, Zee, hat-shaped
purlins, studs, and track are based on post-buckling
strength. Post-buckling strength is based on the concept
that compression flanges and portions of webs will exhibit
some local buckling prior to the load capacity of the
member being reached. To account for this, the widths of
the flat compression elements of the steel deck are reduced
for the purpose of determining the section properties,
excluding the portion that can no longer effectively carry
compression loads. This reduction of the gross section
properties results in the effective section properties.
Steel Thickness
The thickness of steel floor deck is typically specified by
a gage designation. The design of steel deck is dependent
on the specified design base steel thickness in accordance
with AISI S100-2007. The base steel thickness should
not be confused with the total coated thickness, which
is the combined thickness of the base steel, the optional
galvanizing thickness, and any factory-applied paint system
thickness.
The minimum acceptable base steel thickness to be
supplied shall not be less than 95% of the design base
steel thickness. This is specified in Section A2.4 Delivered
Minimum Thickness of AISI S100-2007.
Some standards reference non-mandatory tables that list
the thickness of sheet steel by gage designation. These
include the AISC Manual of Steel Construction in the
Miscellaneous Information section of the appendix and
AWS D1.3 in the Annex. Both references indicate that the
values are non-mandatory and are for reference only. The
nominal total coated thicknesses listed for each gage in
these sources should not be used to determine if the coldformed steel structural member, including steel deck, meets
the minimum thickness requirement for the specified gage.
Effective Section Properties
Effective section properties for a steel deck panel are
used to check for the maximum bending and axial load
capacities.

of the compression elements decreases as the localized


plate-like buckling increases. The bending capacity of the
deck increases with the increase in the grade of steel even
though the affection section properties are decreasing.
The increasing strength of the steel outpaces the decrease
in effective section properties /ft
leading to higher bending
capacities. Steel decks cannot be compared based strictly
on effective section properties without considering the
grade of the steel because of the effect on the effective
properties by the grade of steel. Figure 1.5.1 demonstrates
this for BH-36 steel deck.
20 Gage BH-36 Steel Deck Panel
Yield ksi

Ie+
(in4/ft)

Ie(in4/ft)

Se+
(in3/ft)

Se(in3/ft)

Mn+
(Kip-in/ft)

33
37
40
50
55
80

0.193
0.187
0.187
0.177
0.177
0.173

0.237
0.233
0.233
0.227
0.227
0.223

0.235
0.233
0.232
0.228
0.227
0.218

0.251
0.247
0.244
0.236
0.233
0.230

4.65
5.17
5.56
6.83
7.34
7.84

Figure 1.5.1: EFFECTIVE SECTION PROPERTIES

Many steel deck panels are not symmetric. In most cases,


the top and bottom flange widths are not equivalent. The
bending stress and location of the neutral axis is therefore
different for positive and negative bending, resulting in
different positive and negative section properties.
Gross Section Properties
The gross section properties of the steel deck are based
on the entire cross section of the panel. Determination of
gross section properties assumes that there is compression
buckling of the compression flanges or web elements of
the steel deck, therefore there are no ineffective elements.
The gross section properties are used in combination with
effective section properties to determine the deflection of
the steel deck under uniform out-of-plane loads, and for
checking axial compression and bending.
Service Load Section Properties
The service load moment of inertia is used to determine
the deflection of the steel deck for out-of-plane loads. The
calculated moments of inertia are determined at a working
stress level of 0.6Fy. Following accepted practice, the
hybrid moment of inertia is based on the sum of two times
the effective moment of inertia, and the gross moment of
inertia divided by three, as follows.

The effective properties are determined at the full yield


stress of the steel. As the grade of steel increases, the
effective section properties decrease. The effective width

20

Composite and Non-Composite Deck Catalog May 2014

Id =

2Ie + I g
3

www.ascsd.com

TABLE OF CONTENTS
GENERAL INFORMATION

Steel Deck Section Properties 1.5

How to Read Section Properties Table

Panel Gage

3W PANELS

Weight of
Panel Section
Per SQFT

Gross Section Properties are


Identified by the Subscript, g

Base Metal Thickness


(without Coating)

Effective Section Properties


are Identified by the
Subscript, e

2W PANELS
B PANELS
N PANELS

Effective Net Area


of Section

Hybrid Moment of
Inertia for Uniform Load
Condition Only

C PANELS

Effective Section
Properties at
Service Load
Conditions

Positive and Negative


Effective Moment of Inertia
for Non-Uniform Load
Conditions

Figure 1.5.2: SAMPLE OF 3WH-36 PANEL PROPERTIES TABLE

D PANEL

www.ascsd.com

at or above the onset of localized compression buckling


exhibit progressively lower effective section properties as the
bending stress goes up. Using the weighted average of the
gross and effective section properties is an effective method
to address deflections in which section properties change
depending on the bending stress.

Composite and Non-Composite Deck Catalog May 2014

21

ACUSTADEK

This deflection equation for uniformly distributed loads takes


into account that throughout the length of the span, portions
of the steel deck will have low bending stress and others will
have high bending stress. The areas with low bending stress
exhibit behavior based on gross section properties because
the stress is below the onset of localized compression
buckling. The portions with high bending stress that are

TABLE OF CONTENTS

1.6 Web Crippling

Steel Deck Reactions at Supports


Steel deck reactions at supports are governed by the web
crippling capacity of the steel deck webs on the supporting
member. This is calculated in accordance with Section C3.4
of AISI S100-2007 for multi-web steel decks.
Reactions Due to Uniform Loads
The end and interior reactions listed in the tables in this
catalog are for a uniformly distributed out-of-plane load
applied to the deck (See figure 1.6.1 and 1.6.2).

Point or Line Load Reactions


For load conditions that exceed the uniform reaction capacity
tables, including point loads and line loads on the steel deck
panel, the maximum reaction capacity should be based on
the web crippling capacity for the steel deck. For reactions
exceeding the published values, or for conditions other than
a uniformly distributed load, the maximum reaction capacity
shall be determined by the designer in accordance with
section C3.4 of the North American Specifications for the
Design of Cold-Formed Steel Structural Members for multiweb steel panels and the geometric constants presented in
the web crippling tables for the deck panel.

UNIFORM DISTRIBUTION LOAD

R, EN

D RE

ACT
IO

N (p

R
REA, INTER
CTIO IOR
N (p
lf )

lf )

Figure 1.6.1: UNIFORM DISTRIBUTED OUT-OF-PLANE LOAD

The allowable Rn/ and factored Rn reactions presented


in the tables are in pounds per linear foot running axially
along the support for a given deck-bearing length on the
support (the support member width that the deck bears on).
This is based on the web crippling capacity multiplied by the
number of webs per foot. Figure 1.6.3 shows how to read the
reaction tables in this catalog.
Panels must be attached to supports with fastener patterns
not less than the minimum attachment patterns shown for
the deck panel.

UNIFORM LOAD (psf)

UNIFORM LOAD (psf)

R
UNIFORM LOAD (psf)

R
INTERIOR
BEARING
LENGTH

Figure 1.6.2: SUPPORT REACTIONS

22

Composite and Non-Composite Deck Catalog May 2014

www.ascsd.com

TABLE OF CONTENTS
GENERAL INFORMATION

Web Crippling 1.6

How to Read Web Crippling Table

3W PANELS

Support Condition: Deck Panel End on Supports


or Deck Panel Continuous Over Supports

ASD Design Basis


Panel
Gage

Bearing Length of Deck Panel Web


on Support

2W PANELS

LRFD Design
Basis

Gage

B PANELS
N PANELS

Geometric Constants Describing


Deck Panel Geometry

C PANELS

Allowable Reaction of Deck Panel on Interior End


Support with 2 of bearing
Allowable Reaction of Deck Panel End
on Support with 1.5 Bearing

Figure 1.6.3: SAMPLE OF WEB CRIPPLING TABLE

D PANEL
ACUSTADEK

www.ascsd.com

Composite and Non-Composite Deck Catalog May 2014

23

TABLE OF CONTENTS

1.7 Steel Deck as a Concrete Form

introduction
The design of deck as a form for concrete is based on ANSI/
SDI C-2011 for composite deck and ANSI/SDI NC-2010
for non-composite deck. The deck acts a permanent form
for the concrete. In addition to providing formwork for
the concrete, the deck provides the tension reinforcing
for composite deck-slab systems. The deck also provides
a safety floor for erection and a working platform for
construction trades. It is critical that the deck be designed to
carry these loads to meet the expected performance.
Maximum Unshored Span Tables
The maximum unshored spans for single, and uniform
double or triple deck span conditions are included in the
load tables for the decks in this catalog. This provides an
easy to use design aid to help select the appropriate deck
type and gage for a particular span. The maximum unshored
spans are determined in accordance with ANSI/SDI C-2011.
This design standard provides the minimum recommended
loads the deck is required to support including the weight
of the deck, concrete, and 20 psf uniform construction live
load or 150 plf concentrated construction live load. These
maximum unshored spans may not be appropriate for heavy
construction live loads from concrete buggies, drive on deck
laser screeds, or ride on power trowels. Maximum unshored
spans for loading conditions and span conditions that
exceed the load table should be determined by the designer
of record for the project or the engineer responsible for the
erection of the structure.
In addition to considering the loading used to develop the
maximum unshored span in the tables, the definition of span
and maximum reactions at supports need to be considered.
It is appropriate to consider the span as clear span between
supports when the supports have relatively ridged flanges
as compared to the deflection of the deck. On supports
without ridged flanges such as cold-formed Cees, Zees, open
web steel joists, and thin ledger angles, center-to-center
span is more appropriate.
The maximum spans may be governed by the maximum
reaction capacity of the composite deck at supports. ASC
Steel Deck does not specify a minimum bearing length
of deck on a support, however, allowable and factored
reaction tables are presented for each deck type. This
provides the maximum reaction for the deck based on the
bearing length of the deck on a support. This is limited by
the web crippling capacity of the deck. The deck span may
be limited by the maximum reactions for heavily loaded or
long spanning deck. (See figure 1.7.2 on page 24)
Design Loads for Steel Deck as a Form
Steel deck as a form should be designed to resist the
anticipated construction loads applied to the steel deck.
The design should meet the minimum design loads
specified in ANSI/SDI C-2011 Standard for Composite Steel
Floor Deck-Slabs. This standard provides the minimum

24

recommended loads and load combinations for steel deck


as a form. This includes the dead weight of concrete, and
20 psf uniform construction live load or 150 lbs concentrate
load per foot width of deck. Heavy equipment loads from
concrete buggies, drive on deck laser screeds, and ride-on
power trowels exceed the minimum design loads. It is
critical that the maximum unshored spans be checked by
the designer of record or the engineer responsible for the
erection for the structure for heavy equipment loads on
deck used as a form.
ANSI/SDI C-2011 basic ASD combinations include the
following used to develop the tables in this report.
Wdc+wdd+wlc

ANSI/SDI C-2011

Eq 2.4.1

Wdc+wdd+Plc

ANSI/SDI C-2011

Eq. 2.4.2

Wdd+wcdl 50psf

ANSI/SDI C-2011

Eq. 2.4.2

Wdc = dead weight of concrete

Wdd = dead weight of the steel deck


Wlc = uniform construction live load
(combined with fluid concrete) not less than 20psf
Wcdl = uniform construction live load
(combined with bare deck) not less than 50psf
Plc = concentrated construction live load per unit width
of deck section; 150lbs on a one foot width
Loading Note:
1. For form decks (non-composite), additional concrete dead
load is required for single spans in accordance with ANSI/SDI
NC-2010

Design of Steel Deck as a From


The design of deck as a form is a straight forward engineering
exercise. The deck is no more than a cold formed steel
beam spanning between the support framing. The provision
of AISI S-100 should be used to determine the strength of
the deck. The bending moment, web shear, and reactions
are determined using engineering mechanics for slender
beams. ANSI/SDI C-2011, Appendix 1, shows loading
configurations that are typically used for steel deck as a
from. These do not address unequal spans and unique
loading conditions. The maximum moment, web shear,
and reactions are then checked against the decks strength to
determine the appropriate deck type and gage for a project.
The bending strength of a cold-formed steel deck should
be determined in accordance with AISI S-100. Allowable
stress design is commonly used for determining the bending
capacity of the steel deck. Combined bending and web
shear is often ignored because the web shear stress is
relatively small compared to the bending stress. The section
properties for steel deck are provided in this catalog to aid
in the design of decks exceeding the scope of the maximum
unshored span tables.

Composite and Non-Composite Deck Catalog May 2014

www.ascsd.com

TABLE OF CONTENTS

3W PANELS

The reactions of the steel deck at supports should be


checked to ensure that the webs of the steel deck do not
buckle. The allowable web crippling of the deck may be
taken directly from the web crippling tables in this catalog.
For conditions exceeding the scope of the tables, the web
crippling will need to be determined in accordance with
AISI S-100. To help the designer, the flat width of the web
(h), bend radius (r), and angle relative to the support () are
included in the tables.

GENERAL INFORMATION

Steel Deck as a Concrete Form 1.7

2W PANELS

It is important that deck used as a form does not over


deflect. ANSI/SDI C-2011 limits deflection to L/180, but
not to exceed inch. The deflection check is based on
the weight of the deck and concrete using equations of
engineering mechanics. Skip loading and constitution live
loads are not considered because these loads are not present
after the concrete is finished and during the curing time.
For the maximum unshored span tables presented in this
catalog, ASC Steel Deck allows for an additional 3 psf for
normal weight concrete and 2 psf for lightweight concrete
to account for added concrete due to deflection. ANSI/
SDI C-2011, Appendix 1, has equations for deflection for
common conditions. The actual deck deflection may vary
from the predicted deflection, however, the predicted limits
have proven to be reliable for the design of deck as a form.

B PANELS
N PANELS

Cantilevers
Cantilevering deck is an acceptable common solution to
extending the composite deck-slab past a support, and
generally involves the use of a two piece pour stop as
shown in figure 1.7.1. Cantilevers need to be designed by
the engineer of record or the engineer responsible for the
erection of the structure. The section properties included in
this catalog provide the basic properties for this calculation.
The cantilever should be design in accordance with ANSI/
SDI C-2011 section 2.4.

C PANELS
D PANEL

Backspan(s)

Cantiliever

Figure 1.7.1: Cantilevers

ACUSTADEK

www.ascsd.com

Composite and Non-Composite Deck Catalog May 2014

25

TABLE OF CONTENTS

1.8 Composite Deck-Slab Design

General Design Principles


The design of composite steel deck-slab systems reflect the basic
engineering concepts used to design reinforced concrete beams.
The concrete acts as the compression material, and the steel
deck bonded to the bottom of the concrete acts as the tension
steel. In this manner, the composite deck-slab behaves like a
simple reinforced concrete beam in which the deck is the rebar.
A composite deck-slab is most commonly designed as a
simple span beam. The deck only provides positive bending
reinforcement. The minimum temperature and shrinkage
reinforcing is not adequate to develop negative bending
over supports. With out any significant negative bending
reinforcement over supports, the concrete is assumed to crack
and the deck yield in negative bending, creating a condition
in which the composite deck-slab is treated as a simple beam.
(See figure 1.8.1)
Tension Crack

Uniform Load

Tension Crack

warranted in conditions in which ASD is unfavorable. An


example would be a case in which a large portion of the
superimposed load is dead load. In these situations, a great
portion of the load would use a 1.2 load factor for dead load,
and a smaller portion of the load would use a 1.6 load factor
for live load. In these cases, an LRFD approach will prove to
be more efficient if the maximum superimposed load carrying
capacity is governing the design. LRFD is a good choice for
composite deck-slab systems supporting heavy loads such
as equipment pads and heavy planting beds for green roof
systems or patio decks.
Loading
Composite deck-slab systems are a very efficient way to
support many design loads. The loads should be static or
semi-static in nature. These are typical of dead loads and
typical commercial building live loads. Live loads that are
cyclic or vibratory in nature, however, may break down
the bond between the deck and slab over time. These loads
should not be applied to composite deck-slab systems without
supplemental reinforcing. Loads to watch out for:
Vibratory or Cyclic Loads: Machinery that
vibrates or applies a repetitive cyclic load should be
avoided. This type of equipment may break down
the bond between the concrete and deck due to
vibration or high and localized bending and shear.

Figure 1.8.1: Single Span

The maximum load carrying capacity of a composite deckslab system should be limited to the bending capacity, vertical
shear, and maximum acceptable deflection. ANSI/SDI C-2011
provides the design methods for composite steel deck-slab
systems. The tables in this catalog provide an easy to use
design aid following these methods.
Superimposed Load Capacity
The superimposed load that the composite deck-slab system
carries are those loads that are in addition to the concrete and
deck self-weight. These loads consist of out-of-plane dead and
live loads. Most composite deck-slab systems are designed using
Allowable Stress Design (ASD). This is a convenient method
because either calculations or load tables can be developed
based on service loads. ASD design does not take into account
the different load factors for dead and live loads of 1.2 and 1.6
respectively. Most ASD superimposed load calculations and
load tables assume that the entire superimposed load is a live
load using a load factor of approximately 1.6, which heavily
favors live loads and is therefore conservative for dead loads.
ASD is best suited for applications for which the majority of the
load is live load, which is typical for most commercial building
floor applications.
Load and Resistance Factor Design (LRFD) is a more efficient
method of design for superimposed loads that are primarily
dead load. This method is more involved and is only

26

Forklift Loads: Forklifts tend to create very


high localized wheel loads that apply significant
localized bending and shear to the composite deckslab system and should be avoided.
Hard Wheeled Loads: Heavily loaded hard
wheeled carts may apply high localized bending
and shear below the wheels that may approach the
design capacity of the composite deck -slab system
and should be avoided.
These types of cyclic or vibratory loads may be applied to
composite deck-slab systems if supplemental reinforcing
designed to carry the load is added to the concrete section. In
this case, the deck is considered a stay in place form, similar
to a form deck.
Parking Structures: Composite deck-slab
systems have been used successfully for parking
structures for many years. The combination of
the relative light weight of automobiles with
pneumatic tires that distribute the load and
suspension, greatly reduce the effects of dynamic
cyclic loading on the composite deck-slab system.
For open parking structures, it is recommended
that the slab be sealed to reduce possible
corrosion of the steel deck from water penetrating
cracks in the slab. Supplemental reinforcing in
the slab is recommended in exposed conditions
in which the deck could corrode over time.

Composite and Non-Composite Deck Catalog May 2014

www.ascsd.com

TABLE OF CONTENTS

Fct

Figure 1.8.2: Uncracked Section

Cracked Section
The cracked section for composite deck-slab systems is
determined using methods similar to reinforced concrete
design. For composite deck-slab systems, this is determined
at a compressive yield stress in the concrete in which the
flexural stress is still assumed to be linear elastic and the
concrete in tension is cracked and is no longer contributing
to the section properties. (See figure 1.8.3) The cracked
moment of inertia is presented in the composite deck tables
in this catalog for common slab conditions. For conditions
exceeding the scope of the tables, the cracked moment of
inertia should be calculated in accordance with ANSD/SDI
C-20ll Appendix 4.
Neutral Axis of
Deck-Slab at Yelld

Fc

Fs

Neutral Axis
of Steel Deck

C PANELS

Figure 1.8.3: Cracked Section

Composite and Non-Composite Deck Catalog May 2014

27

ACUSTADEK

Bending Capacity
The flexural capacity for composite steel deck-slab systems
is determined using methods similar to reinforced concrete
design. In this catalog, the nominal bending capacity for
deck-slab systems that are not anchored to the structure with
headed shear stud anchors are developed using the ANSI/SDI
C-2011 prequalified method. This is referred to as the yield
method in which the nominal bending moment is limited
to the point at which the steel deck begins to yield. This
is determined using the cracked moment of inertia and the
yield strength of the steel deck. The factored and allowable
bending moments for common composite steel deck-slab
systems are listed in the tables in this catalog. For conditions
exceeding the scope of the tables, the bending capacity
should be calculated in accordance with ANSI/SDI C-2011

D PANEL

www.ascsd.com

Neutral Axis
of Steel Deck

N PANELS

Un-Cracked Section
The uncracked section for composite steel deck-slab
systems is analogues to reinforced concrete design. The
uncracked section properties are determined at low bending
stress, in which the concrete is still effective in tension. This
is the condition in which the concrete in tension, has not
cracked, and still contributes to the section properties. (See
figure 1.8.2) The uncracked moment of inertia is presented
in the composite deck tables in this report for common slab
conditions. For conditions exceeding the scope of the table,
the uncracked moment of inertia should be calculated in
accordance with ANSD/SDI C-2011 Appendix 4.

Fs

B PANELS

Composite Deck-Slab Section Properties


The development of section properties for composite
deck-slab assemblies follows the engineering mechanics
used to develop section properties for reinforced concrete
design. The convention in design of composite deck-slab
systems is to use the transformed section to convert the
area of steel into an equivalent area of concrete. The
transformed section properties are then used to determine
the nominal bending moment and predicted deflections for
the composite deck-slab section.

Fc

2W PANELS

Temperature and Shrinkage Reinforcing


Reinforcing should be provided in the concrete to
prevent temperature and shrinkage cracking. This can be
accomplished with welded wire fabric, reinforcing steel,
or fibers. The minimum steel reinforcing should not be
less than 0.00075 times the area of the concrete, but not
less than 6x6 Wl.4xWl.4 welded wire fabric. Steel fibers
may be used when the concrete is designed in accordance
with ASTM C1116 type I with steel fibers per ASTM A820
type I, II or V, provided at the manufactures recommended
dosage, but not less than 25lbs/cy. Macro synthetic fibers
may be used when the concrete is designed in accordance
with ASTM C 1116 type III, with fibers in accordance with
ASTM D7508 provided at the manufacturers recommended
dosage, but not less than 4lbs/cy. Other types of fibers that
effectively resist temperature and shrinkage cracking may
be used at the fiber manufactures recommended dosage.
This is appropriate because any increase in concrete
strength that may result from temperature and shrinkage
control using fibers is not considered when developing the
load carrying capacity of the composite deck-slab.

Neutral Axis of
Deck-Slab at Fct

3W PANELS

Concrete
Composite steel deck utilizes structural concrete fill poured
over the top of the steel deck. The design of the concrete
should be in accordance with ACI 318 with a minimum
compressive strength of 3000psi. ASC Steel Deck's load
tables are based on either 145 pcf normal weight concrete
or 110 pcf lightweight concrete. Composite deck systems
can be designed with lower or higher density light weight
concrete, but it is important that the effect on fire rating be
considered if applicable to the project.

GENERAL INFORMATION

Composite Deck-Slab Design 1.8

TABLE OF CONTENTS

1.8 Composite Deck-Slab Design

prequalified sections method. The embossment factor (K) for


this method is presented in General Note 7 of section 1.18,
Composite Deck-Slab Table General Requirements along
with the embossment geometry.
Vertical Shear
The vertical shear capacity for a composite deck-slab
system is the combination of the shear contribution of the
concrete and the steel deck. The factored and allowable
vertical shears are presented in the tables in this catalog.
For conditions that exceed the tables, the shear should be
determined in accordance with ANSI/SDI C-2011.
Deflection
The deflection of a composite deck-slab system should
be checked to ensure serviceability of the system for
its intended use. The superimposed load tables in this
catalog have been limited to strength or L/360 deflection
limit. L/360 was chosen because it is the typical live load
deflection limit for floor systems. Deflection was checked

28

using the average of the cracked and uncracked section


properties.

Id =

Iu + Ic
2

The average moment of inertia for deflection (Id) is presented


in the tables in this catalog for common conditions. This can
be used to check the deflection for both lower and higher
deflection limits.
Concentrated Load
Concentrated point loads and line loads should be
checked using the composite deck properties including the
maximum bending moment, vertical shear, and moment of
inertia for the deflection check. ANSI/SDI C-2011 section
9 provides a general solution for concentrated loads on
steel decks, including the design of load distribution
reinforcing in the slab.

Composite and Non-Composite Deck Catalog May 2014

www.ascsd.com

TABLE OF CONTENTS

Temperature and Shrinkage Reinforcement


The minimum reinforcing for temperature and shrinkage control
should be in accordance with ACI 318.
Non-Composite Deck Load Tables
Non-composite deck uniform load tables are provided in this
catalog. The tables include the maximum unshored span and
the maximum uniform load capacity of the non-composite deck.

2W PANELS

Deck as a Form
The design of deck as a form shall be in accordance with ANSI/
SDI NC-2010. Section 1.7 of this catalog discusses the design
of deck as a form.

Concrete Slab Design


The design of a concrete slab above a non-composite deck
should be in accordance with ACI 318. This includes bending
capacity, vertical shear, and diaphragm shear. It is acceptable
to ignore the contribution of the concrete in the flutes of the
deck when designing the concrete section. For this method of
design, the minimum thickness of concrete above the steel deck
is 112 inches.

3W PANELS

General
Non-composite steel deck design assumes that the steel deck
and concrete do not interact to develop composite sections for
bending. The design of non-composite deck should be done
in accordance with ANSI/SDI NC-2010 Standard for NonComposite Steel Floor Deck. The most common non-composite
deck design is to use the deck as a permanent form and to design
the reinforced concrete in accordance with ACI 318. Another
less common option is to design the deck to carry all the design
loads, including the weight of the unreinforced concrete. For
this option, the design of the deck should follow the provisions
of AISI S100 Specification for the Design of Cold-Formed Steel
Structural Members.

GENERAL INFORMATION

Non-Composite Deck-Slab Design 1.9

B PANELS
N PANELS
C PANELS
D PANEL
ACUSTADEK

www.ascsd.com

Composite and Non-Composite Deck Catalog May 2014

29

TABLE OF CONTENTS

1.10 Penetrations and Openings

General
Openings and penetrations in composite deck-slab floor and
roof structures are a normal part of every building. These can
range from small pipe and conduit penetrations, to mid-sized
openings for mechanical ductwork, to large openings for
stair wells or elevator shafts. Small penetrations less than 6
inches across may not require much, if any, structural design
consideration unless several are grouped closely together.
Mid-sized openings up to 2 to 3 feet across most likely require
design consideration to address the appropriate distribution
of load around the opening for both deck as a form and the
composite deck-slab system. Large openings are generally
designed with support framing around the openings that is part
of the overall framing for the composite deck-slab floor or roof
system. It is difficult to have a rule-of-thumb for unscheduled
openings because of the wide variety of building conditions.
The information in this section should provide guidance toward
addressing a wide range of penetrations and openings in the
composite steel deck-slab system.
Deck-Over or Cut-Out?
The one major consideration that determines the complexity
of designing penetrations or openings in the steel deck is
whether to Decked-Over or Cut-Out the deck. This impacts
how the penetration affects the deck as a form and what type
of deck stiffeners or opening frames should be considered.
For purposes of this catalog, when Decked-Over or Cut-Out
are italicized they shall have the following definitions.
Decked-Over: an opening or penetration through
the deck-slab system in which the deck is placed,
the penetration or opening is blocked out with
formwork, Styrofoam, or edge form flashings without
cutting the deck, the concrete is poured and allowed
to adequately cure, then the deck is cut out when
the opening is needed. (See figure 1.10.1)

Steel Parallel Edge Form

Steel Perpendicular Edge Form

Styrofoam Blockout
Figure 1.10.1: DECKED-OVER OPENINGS

30

Cut-Out: an opening or penetration through the


deck-slab system in which the deck is placed, the
penetration or opening cut out, deck stiffeners
or support frames are installed (if required), the
opening is flashed with edge form or sleeving cans,
then concrete is poured and allowed to cure.
Penetrations or openings that are Decked-Over have several
key advantages, including simplifying the design of the deck
as a form and providing fall-protection safety for mid-size and
large openings. When the Decked-Over approach is used,
the steel decks bending capacity and vertical shear capacity
is not reduced from an opening being cut in the deck. In
the Decked-Over case, no additional design effort needs
to be considered because unshored spans do not change
as the bending capacity and vertical shear capacity have
not been reduced. Another advantage is for mid-sized and
larger openings is that the deck provides the fall protection,
eliminating the need to plank over or put up handrails around
the openings in accordance with OSHA regulations. The
primary disadvantage of Decked-Over openings is that they
cannot be cut out and utilized until after the concrete slab has
been poured and had adequate time to cure.
Penetrations or openings that are Cut-Out have the advantage
of being immediately available for use. The disadvantage
of Cut-Out openings is that the opening in the deck is cut
out, therefore compromising the bending capacity and the
vertical shear of the deck in the area of the opening. For small
openings in most common conditions, the amount the deck
is compromised is insignificant and can typically be ignored.
For mid-size openings, the amount the deck is compromised
is significant and will most likely require stiffening or a
structural support frame. Another disadvantage is that CutOut openings also require fall protection planking or hand
rails to prevent injuries in accordance with OSHA regulations.
Small Size Penetrations
Small size penetrations of 12 inches or less often do not
require any structural design or detailing. These penetrations
are typically for pipes, conduits, or small ductwork. It is
up to the designer of record to determine whether specific
design and detailing is required for small size penetrations.
The following are common examples of methods to stiffen
the deck around small openings and penetrations that may be
considered by the designer.
Decked-Over small penetrations is the recommended method
because the designer does not need to consider whether the
penetration will affect the capacity of the deck as a form,
because the deck is not cut out. The only issue that may need
to be considered is load distribution around the opening.
If required, this can be accomplished by placing rebar to
distribute the loads around the opening. For most common
floor applications, this is not necessary for openings less than
12 inches unless several are grouped together.

Composite and Non-Composite Deck Catalog May 2014

www.ascsd.com

TABLE OF CONTENTS

rebar to distribute to the deck-slab adjacent to the openings.


(See figure 1.10.3) Reinforced concrete design to distribute
these loads the load perpendicular to the deck span should
be done in accordance with ACI 318.

Distribute
1
2 Tributary
Load

2W PANELS

Collect
Tributary
Load

Figure 1.10.2: DECK SUPPORT ANGLES

Cut-Out mid-sized openings require structural design and


detailing of the deck as a form and the composite deck steel
deck-slab. Cut-Out openings compromise the deck bending
and shear capacity. For openings less than 2 feet stiffener
angles may be an acceptable solution similar to those used for
small penetrations. The designer of record should verify the
size of the stiffener and that the adjacent deck can support the
concrete and construction loads. For all mid-sized openings,
deck support frames may be a good option to support the
deck for the concrete and construction loads. The designer
of record should design and detail these frames around the
mid-sized openings to transfer the loads back to the primary
framing members supporting the composite steel deck. (See
figure 1.10.4) Steel angles or channels are common framing
materials for mid-size openings.

www.ascsd.com

Composite and Non-Composite Deck Catalog May 2014

ACUSTADEK

Decked-Over mid-size openings require less structural design


and detailing than Cut-Out. If the opening is Decked-Over,
the deck as a form is not compromised therefore no stiffening
angles or support frames are required. The design should
consider the effect of load transfer around mid-size openings
for the composite steel deck-slab design. The superimposed
load and dead load of the deck-slab needs to be distributed
around the opening. This can be accomplished by using

D PANEL

Mid-Size Openings
Mid-sized openings typically require some structural design
and detailing consideration. These openings are typically for
ductwork or other mechanical shafts. Mid-sized openings
range from 1 foot to approximately 4 feet, and cut through
multiple webs of the composite steel deck. The following
are common examples of how the design professional may
address mid-size penetrations in their designs.

Figure 1.10.3: REBAR DISTRIBUTION

C PANELS

Load Distribution Angle,


Channel or
tube Steel

Distribution Rebar Design


in Accordance with ACI 318

N PANELS

Distribute
1
2 Tributary
Load

Distribute
1
2 Tributary
Load

B PANELS

Distribute
1
2 Tributary
Load

Collect
Tributary
Load

3W PANELS

Cut-Out small penetrations may require the stiffening of the


deck. Most small openings less than 6 inches that do not
cut through more than 1 web of the deck do not require
any reinforcing. Small Cut-Out penetrations less than 24
inches can be reinforced with stiffening angles, tube steel,
or channels attached to the deck. (See figure 1.10.2) These
details rely on the adjacent decks reserve capacity to support
the load distributed to those flutes due to the penetration CutOut. These distribution angles are an effective way to control
localized deck deflection around the penetration Cut-Out.
They do not, however, address possible overstress or over
deflection of the adjacent flutes of the deck now carrying the
load. Historically this type of detail has been demonstrated to
be an effective solution for small penetrations.

GENERAL INFORMATION

Penetrations and Openings 1.10

31

TABLE OF CONTENTS

1.10 Penetrations and Openings

Consideration for Groups of Openings


When small sized Cut-Out penetrations are grouped together,
the effect of the grouping may need to be treated as a midsized opening or maybe a large size opening. Groups of small
penetrations running along the edge of a support beam can
compromise a large portion of the vertical shear capacity of
both the deck as a form and the composite steel deck-slab
system. (See figure 1.10.5)

Opening Frame Channels,


Angles or Small Wide Flanges
Figure 1.10.4: DBL H OPENING FRAME

Large Openings
Large openings for Stair wells, elevator shafts, or large
mechanical shafts are typically supported by framing that
is part of the primary building framing system supporting
the composite steel deck-slab system. Decked-Over large
openings are often not practical due to the large size of
the opening. Most large openings do not fall into the CutOut category because the deck will be detailed around the
opening with pours stops similar to edge of slab condition

32

Composite and Non-Composite Deck Catalog May 2014

Figure 1.10.5: ROW OF SMALL HOLES

www.ascsd.com

TABLE OF CONTENTS

Collect
Tributary
Load

Figure 1.10.7: SINGLE VS 2 PENETRATIONS

N PANELS

Distribution
1
2 Tributary
Load

When Perpendicular
to Flute Treat as
Single Net Opening

Distribute
1
2 Tributary
Load

B PANELS

Collect
Tributary
Load

2W PANELS

Distribute
1
2 Tributary
Load

When Parallel to
Flute Treat as one
Small Opening

The effect of two small holes in the same flute(s) of the


deck panel may need no more consideration than a single
penetration. The load from the flutes with the penetrations is
distributed to the adjacent webs and is similar in magnitude
to a single penetration. (See figure 1.10.7)

3W PANELS

The effect of several small openings with stiffeners in proximity


to each other may affect the overall capacity of the deck as a
form or capacity of the composite deck-slab system. This may
be an issue when the stiffening angles or penetrations overlap
in a given span. The designer should consider the overlapping
distribution of load on the deck between openings to ensure
the binding capacity of the deck is not exceeded (See figure
1.10.6)

GENERAL INFORMATION

Penetrations and Openings 1.10

Figure 1.10.6: OVERLAPPING HOLES

C PANELS
D PANEL
ACUSTADEK

www.ascsd.com

Composite and Non-Composite Deck Catalog May 2014

33

TABLE OF CONTENTS

1.11 Composite and Non-Composite


Diaphragm Shear

General
A composite steel deck-slab is an integral part of a building's
horizontal diaphragm system. The composite deck-slab acts
as a shear resistant membrane supported by the steel framing
supporting the diaphragm and providing the perimeter cords
and collectors. The composite deck-slab tables in this catalog
provide an easy to use design aid with factored diaphragm
shears for common attachment types.

spacing of the fasteners per sheet shall not be greater than


the spacing of the parallel boundary fasteners. Fasteners may
need to be doubled up in some flutes to achieve this.

Shear Design of Diaphragms


without Welded Shear Studs
The diaphragm shear design of composite deck-slab systems
may be performed in accordance with the SDI Diaphragm
Design Manual. This method is used for deck that is not
attached with headed shear stud anchors. Common attachment methods include arc spot welds, power actuated fasteners, and self-drilling screws. The side laps of the steel deck
should be connected together to prevent concrete leakage
and provide some shear contribution. The minimum side lap
connection should be button punches at 36 inches on center.
Diaphragm Boundary Fasteners to Supports
The diaphragm boundary connections to supports, perpendicular to the deck, should be the specified attachment pattern in the composite tables for the given deck gage, concrete
type, and slab thickness.
Diaphragm boundary fastener spacing, parallel with the ribs
of the deck, shall not exceed the spacing determined by:
dividing the fastener shear strength by the required shear
demand. Connector shear strengths are presented in figures
1.13.11 and 1.13.12

Spacing (in) =

Q fa 12in

sa ft

Spacing (in) =

Q ff 12in

s f ft

Qfa = Allowable fastener strength using the safety factor,


= 3.25, for composite deck-slab diaphragm shear
in accordance with ANSI/SDI C-2011, lbs
Qff = Factored fastener strength using the safety factor,
= 0.5, for composite deck-slab diaphragm shear in
accordance with ANSI/SDI C-2011, lbs
Sa = Allowable shear demand, lbs/ft
Sf = Factored shear demand, lbs/ft
Skew Cut Diaphragm
At skew cut conditions, the minimum number of fasteners is
determined based on the location of the fasteners in the ribs
per the perpendicular attachment schedule. The average

34

S
idth
Panel Wasteners
of F
r
e
b
m
u
N

Figure 1.11.1: SKEW DIAPHRAGM

Diaphragm Deflection
Composite deck-slab diaphragms are very stiff with a flexibility factor, f<0.5micro inches/lbs (Shear stiffness, G >
2000 kip/inch). The specific predicted shear stiffness (G) for
a given composite deck-slab condition can be determined
in accordance with the methods in ANSI/SDI C-2011. Due
to the very stiff nature of these systems, checking the shear
deflection of the diaphragm is often not necessary. There may
be occasions, however, to check diaphragm shear deflections for diaphragms with large length to depth ratios. For
these conditions, the methods and equations of engineering
mechanics presented for diaphragm deflections in the ASC
Steel Deck Roof Deck Catalog may be used.
Diaphragm Shear With Headed Shear Stud Anchors
Diaphragms requiring diaphragm shears that exceed the
limits of the arc spot welds, power actuated fasteners, or selfdrilling screws may be developed using headed shear stud
anchors and supplemental shear reinforcing in the concrete
slab above the deck. This design is based on the transfer
of shear from the collector into the reinforced concrete slab
above the deck using headed shear stud anchors. The capacity of the diaphragm is limited by this shear transfer, or the
capacity of the reinforced concrete diaphragm above the
deck. The capacity of the headed shear stud anchors should
be determined in accordance with AISC 360 requirements
for composite beam design. The in-plane shear capacity for
the reinforced concrete diaphragm above the deck should
be determined in accordance with ACI 318 requirements for
reinforced concrete design. The composite deck-slab tables
in this catalog provide factored diaphragm shear capacities for
common reinforcing schedules with inch diameter headed
stud anchors.

Composite and Non-Composite Deck Catalog May 2014

www.ascsd.com

TABLE OF CONTENTS
GENERAL INFORMATION
3W PANELS
2W PANELS
B PANELS
N PANELS
C PANELS
D PANEL
ACUSTADEK

www.ascsd.com

Composite and Non-Composite Deck Catalog May 2014

35

TABLE OF CONTENTS

1.12 Composite Deck-Slab Tables

General
The composite deck-slab load tables are intended to provide
a designer with easy to use design aids for common composite deck-slab conditions. The tables provide uniform load in
both allowable and factored superimposed loads. Factored
diaphragm shears are provided for composite deck-slab systems for lateral design. Diaphragms may be attached with
a variety of attachments to supports including traditional arc
spot welds, power actuated fasteners (PAF), and self-drilling
screws. Factored shear tables for diaphragms with steel
reinforcing and headed shear stud anchors are provided for
high shear diaphragms. All of these tables are supported with
complete composite deck-slab properties including bending
moment, vertical shear, and section properties to aid in the
design of conditions exceeding the scope of the tables.
Superimposed Uniform Load Tables
Uniform superimposed load is the load that the composite deckslab can carry in addition to its self-weight. Both allowable and
factored superimposed loads are provided. The superimposed
load tables assume that the minimum temperature and shrinkage
reinforcement is not adequate to develop negative bending resistance at supports, therefore all spans are treated as simple spans.
Most floor systems are designed using allowable stress design
(ASD). The allowable superimposed load tables present the
minimum uniform load based on the allowable bending strength,
allowable vertical shear, and a deflection limit of L/360. ASD
assumes that the superimposed load is primarily live load and is
conservative for dead loads.
Load and Resistance Factor Design (LRDF) is recommended for
conditions in which the majority of the superimposed load is
dead load, and the maximum superimposed load is the limiting
design criteria. The factored superimposed loads in the tables do
not include a deflection check. The designer will have to check
the service load deflection to ensure that the deflection meets
the projects deflection serviceability requirements when using
an LRFD approach.
Composite Deck-slab Properties
For conditions exceeding the scope of the uniform load tables,
composite deck-slab properties are provided in the tables. The
properties can be utilized as part of the solution for concentrated
loads, deflection limits, or spans not included in the superimposed load tables. The properties include both allowable and
factored moments, and vertical shear for determining the capacity
of the composite deck-slab system. Cracked, uncracked, and the
average of cracked and uncracked moment of inertia are provided
to assist in determining the deflection of the deck-slab system.
Factored Diaphragm Shear
This catalog presents composite steel deck-slab diaphragm shears
using a load and resistance factor basis. The diaphragm shears
presented are factored shears. Composite steel deck-slab systems
have traditionally been designed using allowable stress design
(ASD), in part because manufactures have presented allowable
shears. These shears were based on research and engineering
studies dating back to before LRFD was commonly used for steel

36

design. The factored shears presented in this catalog work seamlessly with the design of the lateral force resting system for steel
and concrete buildings designed using the LRFD approach. The
designer does not have to convert the lateral forces to ASD when
selecting a factored diaphragm from the shear tables.
Factored shears are provided for a variety of fastener types to
supports. This range of fasteners reflects a full range of building
types that composite deck-slab systems are used in.
Wide Flange Multi-Story Steel Construction: Arc
spot welds are the traditional method for attaching
composite deck to structural steel support members.
This method provides good shear performance and
is applicable to a wide variety of support steel, from
heavy wide flange beams to light weight open web
steel joists. Welded steel headed stud anchors are
commonly used for composite beam design. They
are also a good choice to transfer large diaphragm
forces into the composite deck-slab system. This system is ideal for high shear diaphragms on wide flange
beams, and requires the use of welded wire fabric or
reinforcing bars in the slab.
Open Web Steel Joist Mezzanine and Floor Systems:
Composite steel deck-slab systems can be attached
with arc spot welds, however, power actuated fasteners (PAF) are an ideal cost effective method of attachment to light structural angles used for open web
steel joist framing. PAF selection is dependent on the
support steel thickness.
Cold-Formed Steel Mezzanine and Floor Systems:
Self-drilling screws are the best choice for attaching
composite steel deck to cold-formed steel framing.
Common examples of this application include: coldformed steel framed multi-story mini-storage buildings, mezzanines, and conventional cold-formed
steel stud, and joist framed buildings.
Composite Deck-Slab with Cellular Deck
Cellular composite deck panels can be conservatively designed
using the non-cellular deck-slab tables. The superimposed
loads, vertical shear, and moment of inertia can be conservatively based on the gage of the beam section of the cellular profile.
This ignores the contribution of the steel used for the bottom pan
of the cellular deck. Maximum unshored spans for cellular deckslab system are listed with the cellular deck section properties.
Allowable Stress Design
Historically, most composite steel deck-slab systems diaphragm
shear tables have been presented using an allowable stress
design basis. To compare composite steel deck-slabs designed
using ASD basis, it is recommended that the ASD shear demand
be converted back to an LRFD basis. This can be accomplished
by dividing the required allowable shear by 0.7 ASD seismic
factor, for seismic controlled designs, or 0.6 ASD wind factor for
wind controlled designs.

Composite and Non-Composite Deck Catalog May 2014

www.ascsd.com

TABLE OF CONTENTS

How to Read Tables

3W PANELS

3WH-36 Composite Deck


5" Total Slab Depth
Normal Weight Concrete (145 pcf)
Concrete Volume 1.102yd3/100ft2

Theoretical concrete
volume does not
account for deflection

Vertical load
span of deck
Allowable
superimposed
live load capacity
Factored
superimposed
load

No load shown
when greater
than allowable
superimposed
live load

Factored
diaphragm shear
corresponding to
type of fastener

Allowable
factored vertical
shear of deck
slab

Attachment
type to
supports

Welded Wire
reinforcing
required to
develop shear
when studs are
used

Weight of
deck-slab

Cracked &
uncracked
moment of
inertia of
deck-slab

Factored
diaphragm
shear when
studs are
used on
collectors

Minimum area of
60ksi reinforcing
as an alternative
to wwf

D PANEL

Combined
momentum
of inertia of
deck-slab

C PANELS

Allowable
factored
momentum of
deck slab

N PANELS

Attachment
pattern for
weld, pafs of
screws

Spacing of
shear studs
when used

B PANELS

Superimposed
load that
produces L/360
deflection

2W PANELS

Maximum
Clear Span
without
Shoring

GENERAL INFORMATION

Composite Deck-Slab Tables 1.12

Figure 1.12.1: SAMPLE OF 3WH-36 COMPOSITE DECK TABLE

ACUSTADEK

www.ascsd.com

Composite and Non-Composite Deck Catalog May 2014

37

TABLE OF CONTENTS

1.13 Support Fastening

Support Fastening
A variety of fastening systems may be used to connect steel deck
to the supporting steel members. The type of fastening system
used depends on the required diaphragm shear capacity, uplift
capacity, and the thickness of the supporting steel members.
These fastening systems include arc spot welds, arc seam
welds, headed stud anchors, self-drilling screws, and poweractuated fasteners (PAF). The strength of each fastener type is
mathematically derived from specified standards and testing.

Arc spot and arc seam welds do not have a mandatory


minimum support member thickness. Experience has shown
that a support thickness as thin as 10 gage is reasonable.
Welders with light gage welding experience can weld steel
deck to thinner gage supports.
Steel headed stud anchors are subject to a minimum support
member thickness in accordance with AISC 360. This
requires that the headed stud anchor be a minimum of 2.5
times the thickness of the supporting beam flange unless the
headed studs anchor is placed directly over the web. For
diameter stud, the minimum flange thickness when the stud is
not directly over the web is 0.3 inches.

The shear strength for arc spot and arc seam welds is derived
from the equations in Section E2.6 of AISI S100-2007. The
strength for self-drilling screws and PAF is determined in
accordance with the Steel Deck Institute Diaphragm Design
Manual DDM03. The strengths for these fasteners are listed
in the Weld and Shear Capacities Table (See figure 1.13.11
and Figure 1.13.12). The shear strength of steel headed
stud anchors is determined in accordance with ASIC 360
Specification for Structural Steel Buildings.

Self-drilling screws are suitable for use with supporting


members from 0.0385 inches to , depending on thread
pitch and drill point configuration. The fastener manufacturer
should be consulted to determine which screw is appropriate.

The pull-out and pull-over capacities for fasteners are in


accordance with Sections E4.4.1 and E4.4.2 of AISI S1002007. The pull-out for PAFs should be obtained from the
manufacturers data for the selected fastener.

Power Actuated Fasteners (PAF) are selected based on a


range of support thickness for a given fastener. Follow the
PAF manufacturers support thickness recommendations. The
fastener selection chart (See figure 1.13.1) provides a quick
and easy guide to help select the appropriate fastening system
for the support member thickness.

Fastener Selection
To ensure quality fastening to supports, the fastener
(weld, screw, or PAF) must be compatible with the
thickness of the steel support member. (See figure 1.13.1)

Base Metal Thickness

Figure 1.13.1: FASTENER SELECTION CHART


Base Metal Thickness
Minimum

Maximum

0.400" min when


not over web

unlimited

Arc Spot Weld*

0.135"

unlimited

12-14 Self Drilling Screw**

0.0385"

0.210

12-24 Self Drilling Screw**

0.125*

0.500

Hilti X-EDN 22 THQ12 High Shear Nail

1/8

1/4

Hilti X-EDN 19 THQ12 High Shear Nail

3/16

3/8

Hilti X-HSN-24 High Shear Nail

1/8

3/8

Hilti ENP19 L15 High Shear Nail

1/4

unlimited

Pneutek SDK61075 Fastener

0.113

0.155

Pneutex SDK63075 Fastener

0.155

0.250

Pneutek K64062 and K64075 Fastener

0.187

0.312

Pneutek K66062 and K66075 Fastener

0.312

unlimited

Fastener
3/4" Shear Stud

*Below 10 gage is not recommended due to the difficulty of producing a good quality weld.

38

1/8

1/4

3/8

1/2

5/8

**Correct drill point must be selected for the base material thickness.

Composite and Non-Composite Deck Catalog May 2014

www.ascsd.com

TABLE OF CONTENTS

End Lapped Deck Condition


2

>emin

Butted Deck Condition

- 1/2
+ unlimitted

>emin

3W PANELS

Minimum Fastener Edge Distance


The minimum edge distance for fasteners used with ASC Steel
Deck profiles has been verified through full-scale diaphragm
shear testing. The minimum edge distance for self-drilling
screws and PAFs is . The minimum edge distance for arc
spot and arc seam welds is . Edge distance is measured
from the center of the fastener or the center of the radius of
an arc spot or seam weld. (See figure 1.13.2)

GENERAL INFORMATION

Support Fastening 1.13

Butted Tight or Gap

>emin

>emin

2W PANELS

de
Figure 1.13.2: END LAP AND BUTTED DECK

Welds used for composite deck-slab or non-composite


deck-slab applications do not require touch up painting.
Specifications should not require the weld to receive
touch-up paint for decks with concrete fill.
Arc spot and seam welds for ASC Steel Deck products are
specified based on the effective diameter or length and
width. This is approximately the diameter or width and
length of a weld at the interface between the deck and
supporting member. The effective weld size is less than the
visible weld size and is verified through the development
of weld qualifications and procedures. See AISI S100-2007
Section E2 for more information regarding weld design.
Weld inspection, procedures, and qualifications should be
in accordance with AWS D1.3

C PANELS

Arc spot welds connecting deck less than 0.028 inches


thick require weld washers in accordance with AWS D1.3.
Weld washers are not recommended for thicker decks. (See
figure 1.13.5)

N PANELS

Welded connections have some drawbacks compared to


screws and PAF. Welds require skilled labor and have a
relatively slow production rate. Additionally, welding cannot
be performed in the rain or if standing water is present on the
deck. Welding often results in burn marks visible from the
underside of the deck and supporting members, which may
be objectionable for some exposed deck conditions. Jobsite
safety is of great concern as welding also creates a fire risk.

Figure 1.13.4: ARC SPOT WELD (weld to support)

B PANELS

Arc Spot and Arc Seam Welds


Traditionally, arc spot welds and arc seam welds are used to
attach steel deck to supports. (See figures 1.13.3 and 1.13.4)
Arc welds have high shear capacity, resulting in diaphragms
with higher shear capacities than screws or power actuated
fasteners (PAF).

D PANEL

de
L

www.ascsd.com

ACUSTADEK

Figure 1.13.3: ARC SEAM WELD (weld to support)

Figure 1.13.5: WELD WASHER

Composite and Non-Composite Deck Catalog May 2014

39

TABLE OF CONTENTS

1.13 Support Fastening

Power-Actuated Fasteners, PAF


Power-actuated fasteners (PAF) are an excellent fastening
system. Commonly referred to as high shear nails or pins,
they can be used to achieve mid to high range diaphragm
shear capacities, depending on the fastener selected and
the support thickness. The benefits of using PAFs is that
they can be installed without skilled qualified welders, are
efficient to install, do not pose a jobsite fire risk, and do
not leave any burn marks associated with welding. This
makes PAFs an attractive option for architecturally exposed
steel deck.

Hilti, Inc.
Hilti, Inc.s PAF system includes powder fired tools to install
their high shear nails (HSN) and ENP fasteners. The operator
of the powder-fired tools must have OSHA compliant
safety training. Contact Hilti, Inc. for fastener installation
instructions and for additional technical support relating
to their fastening systems. (See figure 1.13.7 and 1.13.8)
www.us.hilti.com 800-879-8000
Hilti Inc. Fasteners
X-ENP-19 L15, X-EDN-19 THQ12, X-EDNK-22 THQ12, X-HSN-24

A drawback of PAF systems is that it may be difficult for the


design engineer to select the fastener size when designing
with open-web steel joists because the thickness of the top
chord may be unknown. Good practice would be to design
the diaphragm with the minimum expected substrate steel
thickness, and indicate a range of acceptable fasteners
based on the thickness of the supporting steel member.
The inspection process on the jobsite should be tasked
with ensuring that the correct fastener is used based on the
substrate thickness.
Pneutek
Pneuteks PAF system uses a pneumatic actuated tool. This
system does not use a powder charge to drive the fastener.
Contact Pneutek for fastener installation instructions and
for additional technical support relating to their fastening
systems. (See figure 1.13.6)
www.pneutek.com 800-431-8665

X-EDN-19 THQ12
X-EDK-22 THQ12

hnvs = 3/16 - 3/8

Steel Deck Panel

Structural Steel Member

X-EDP-19 L12

hnvs = 5/16 - 3/8

Steel Deck Panel

Pneutek Fasteners
SDK61075, SDK63075, K64062, K66075, K66056, K66062, K66075

Structural Steel Member

Figure 1.13.7: HILTI X-ENP-19

Pneutek Fastener

X-EDN-19 THQ12
X-EDK-22 THQ12

Head in Contact
Steel Deck Panel
hnvs = 3/16 - 3/8

Structural
Steel Member

Steel Deck Panel

Structural Steel Member

Figure 1.13.6: PNEUTEK K64062

40

Composite and Non-Composite Deck Catalog May 2014

Figure 1.13.8: HILTI X-EDN-19

www.ascsd.com
X-EDP-19 L12

TABLE OF CONTENTS

2W PANELS

Self-Drilling Screws
Self-drilling screws are an excellent option for attaching deck
to thin-gage metal supporting members. (See figure 1.13.10)
Although diaphragms that are attached with screws tend to have
a lower shear capacity than other support fastening systems,
screws install quickly with lower skilled labor and do not leave
any burn marks on the deck or supporting members. This makes
them an attractive option for architecturally exposed steel deck.
Self drilling screws may not be practical on heavier structural
steel support members because it can be time consuming to drill
through the steel deck panel into the supporting member. When
installed, the driven screw penetrates both the steel deck panel
and the supporting member; as a result, the screw points are
visible from the underside of the supporting structure.

3W PANELS

Headed Stud Anchor


The headed shear stud anchor is a traditional method of attaching
metal deck to supporting steel beams. (See figure 1.13.9) Shear
studs are commonly used to develop composite steel beams.
Headed shear stud anchors are an excellent way of transferring
diaphragm shear forces from a collector beam into the composite
deck-slab system. Shear studs replace an arc spot weld, PAF, or
screws on a one to one basis.

GENERAL INFORMATION

Support Fastening 1.13

B PANELS

Self-Drilling Screw

N PANELS

Steel Panel
Steel Support

C PANELS

Figure 1.13.10: #12-24R1-1/4 SCREW

Figure 1.13.9: HEADED STUD ANCHOR

D PANEL
ACUSTADEK

www.ascsd.com

Composite and Non-Composite Deck Catalog May 2014

41

TABLE OF CONTENTS

1.13 Support Fastening


Figure 1.13.11

Nominal Strength
Deck Panel

Gage

WELDING CAPACITIES
Arc Spot (puddle) Weld
(1/2 in effective diameter)
Shear (lbs)

Tensile (lbs)
IBC

Arc Seam Weld


(3/8 in x 1 in effective width & length)
Shear (lbs)

B, DGB, N, DGN

22
20
18
16

2116
2955
4710
5810

2048
2442
3207
3956

3098
3751
5075
6452

2W, DG2W,
3W, DG3W

22
21
20
19
18
16

2002
2532
2820
3950
4635
5738

1988
2252
2383
2837
3156
3907

3001
3434
3652
4425
4985
6359

Deep Deck

20
18
16
14

2595
4011
4965
6193

2048
2717
338/
4188

3161
4314
5503
7143

20/20
20/18
20/16
18/20
18/18

6886
7835
8836
7912
8836

4689
5335
6082
5387
6075

7881
9217
10714
9328
10701

18/16
16/20
16/18
16/16

8836
8836
8836
8836

6958
6148
6958
7867

12238
10714
12238
13817

2WF, DG2WF,
3WF, DG3WF

20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16

6807
7759
8836
7844
8836
8836
8836
8836
8836

4635
5283
6017
5341
6017
6898
6089
6898
7805

7773
9106
10600
9229
10600
12134
10600
10600
13710

Cellular Deep Deck

20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16

5815
6714
7647
6714
7647
8767
7647
8767
8836

3932
4540
5171
4540
5171
5928
5171
5928
6708

6624
7780
9173
7780
9173
10501
9173
10501
11865

BF, DGBF, NF, DGNF

Calculated in accordance with section E of the AISI Cold Formed Steel Design Manual
2004 supplement to the 2001 & 2007 NASPEC

42

Composite and Non-Composite Deck Catalog May 2014

www.ascsd.com

TABLE OF CONTENTS

Figure 1.13.12

Nominal Strength

Deck Panel

Gage

MECHANICAL FASTENER CAPACITIES


Nominal Shear Strength (lbs)
Screws

Hilti

Pneutek
K64062 K63062
K64075 K63075

SDK63075

SDK61075

1735
2216
3009
3686

1728
1977
2417
2812

1546
1833
2378
2896

2W, DG2W,
3W, DG3W

22
21
20
19
18
16

1116
1270
1347
1616
1808
2270

1577
1787
1891
2253
2508
3109

1557
1765
1868
2225
2477
3070

1464
1659
1756
2092
2329
2887

1780
2055
2195
2698
3071
4011

1655
1993
2149
2642
2960
3644

1689
1860
1941
2210
2389
2787

1502
1695
1790
2116
2342
2862

Deep Deck

20
18
16
14

1206
1619
2032
2583

1891
2508
3109
3885

1868
2477
3070
3836

1756
2329
2887
3608

2195
3071
4011
5363

2149
2960
3644
4440

1941
2389
2787
3265

1790
2342
2862
3506

BF, DGBF,
NF, DGNF

20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16

2766
3190
3651
3224
3647
4109
3686
4109
4571

3737
4258
4810
4300
4806
5342
4851
5342
5862

3690
4204
4750
4246
4745
5275
4790
5275
5789

3470
3953
4466
3992
4462
4960
4504
4960
5444

5092
6071
7201
6154
7191
8383
7288
8383
9639

4294
4800
5314
4840
5310
5793
5351
5793
6251

3176
3485
3801
3509
3799
4099
3824
4099
4385

3386
3804
4229
3837
4225
4619
4259
4619
4982

20/20
20/18
20/16
18/20
2WF, DG2WF, 18/18
3WF, DG3WF
18/16
16/20
16/18
16/16

2732
3155
3617
3193
3617
4078
3655
4078
4540

3694
4215
4769
4262
4769
5307
4815
5307
5828

3648
4163
4710
4209
4710
5240
4754
5240
5755

3430
3914
4429
3958
4429
4928
4471
4928
5412

5014
5989
7114
6081
7114
8302
7211
8302
9553

4250
4760
5277
4804
5277
5762
5318
5762
6221

3150
3460
3778
3487
3778
4079
3804
4079
4367

3350
3770
4198
3807
4198
4594
4232
4594
4958

20/20
20/18
20/16
18/20

2411
2824
3238
2824

3646
4215
4769
4215

3600
4163
4710
4163

3385
3914
4429
3914

4928
5989
7114
5989

4202
4760
5277
4760

3121
3460
3778
3460

3311
3770
4198
3770

18/18
18/16
16/20
16/18
16/16

3238
3651
3238
3651
4064

4769
5307
4769
5307
5828

4710
5240
4710
5240
5755

4429
4928
4429
4928
5412

7114
8302
7114
8302
9553

5277
5762
5277
5762
6221

3778
4079
3778
4079
4367

4198
4594
4198
4594
4958

ACUSTADEK

1841
2258
3132
4076

D PANEL

1508
1800
2367
2924

C PANELS

1604
1914
2517
3109

N PANELS

1624
1938
2549
3149

B PANELS

1150
1381
1839
2301

2W PANELS

B, DGB, N,
DGN

22
20
18
16

Calculated in accordance with the Steel Deck Institute Diaphragm Design Manual

www.ascsd.com

Composite and Non-Composite Deck Catalog May 2014

3W PANELS

#12 Self Drill X-ENP-19 L15 X-EDN 19 THQ 12 X-EDNK22 THQ12

Cellular
Deep Deck

GENERAL INFORMATION

Support Fastening 1.13

43

TABLE OF CONTENTS

1.14 Side Seam Fastening

Side Seam Attachment


The side seam attachment for composite floor deck has a
small influence on diaphragm shear capacity, but is critical
for holding the seam together during the concrete pour. The
side seam attachment creates a positive connection, limiting
differential movement between the sheets of deck under outof-plane loads during concrete placement. The common
side seam attachment systems are the Triple Button Punch,
traditional button punch, top seam weld, and DeltaGrip
system for standing seam interlock side seams. Self-drilling
screws are used for nestable side seams. The two common
types of side seams are the standing seam interlock and the
nestable side seam (See figure 1.14.1).

STANDING SEAM

Triple Button Punch


The Triple Button Punch is the latest innovation in reliable
side seam connections for standing seam side laps for
composite steel deck. (See figure 1.14.2) For architecturally
exposed deck, the Triple Button Punch system is the best
option because there are no penetrating holes that can
leak concrete, and no unsightly burn marks typically
associated with welded connections. This connection is
installed using ASC Steel Deck's DeltaGrip tool with the
triple button punch die set. The triple button punch is more
effective than a traditional button punch because the three
dimpled connections are tightly seated using the DeltaGrip
pneumatic tool. The DelatGrip tool produces consistent,
repeatable punches that are not subject to operator fatigue
or punch depth settings that cause quality problems with
traditional hand operated button punch tools.

NESTABLE

STANDING SEAM SCREWABLE SIDELAP


Figure 1.14.1: STANDING SEAM AND NESTABLE DIAGRAM
Figure 1.14.2: TRIPLE BUTTON PUNCH

Traditional Button Punch


The traditional button punch attachment is used to connect
standing seam side seams by creating a single dimpled clinch
connection. (See figure 1.14.3) The quality of a button punch
that has been installed with a hand-operated tool is dependent
on the operator and the depth of the particular punching tool.
A good button punch should not become disengaged when
a person modestly jumps on the adjacent sheet of deck.

Figure 1.14.3: BUTTON PUNCH SIDE LAPS

44

Composite and Non-Composite Deck Catalog May 2014

www.ascsd.com

TABLE OF CONTENTS

Figure 1.14.4: SIDE SEAM SELF-DRILLING SCREW

Figure 1.14.6: SIDE SEAM SELF-DRILLING SCREW

Top Seam Weld


Top seam welds are the least desirable method to connect
standing seam composite decks together. (See figure 1.14.5)
The top seam welds are slow to install, require skilled welders,
and contribute very little to the strength of the composite deck
system. Top seam welds connect the standing seam deck side
seams by welding the three layers of steel deck together. This
is done after the hem is crimped using a hand or pneumatically
operated crimping tool. Top seam welding is a slow process
requiring skilled welders, leading to increased installation
cost. The welding creates burn marks on the underside of the
deck and occasional burn-through holes. Top seam welds
are not recommended for architecturally exposed steel deck.
Weld inspection, procedures, and qualifications should be in
accordance with AWS D1.3. Due to the high cost associated
with installation and inspection of top seam welds the Triple
Button Punch is a better option.

DeltaGrip
The DeltaGrip system was developed in 2003 to reduce
the installed costs of high shear roof deck diaphragms
by eliminating the costly top seam weld. The DeltaGrip
connection has also been proven to be an effective side seam
connection for composite steel decks to keep the deck from
separating during concrete placement. This revolutionary
clinching system punches three triangular tabs though the
standing seam interlock side seam. This interlock creates the
equivalent strength of a time consuming top seam weld with
the rapid action of a pneumatically powered DeltaGrip tool.
High-quality DeltaGrip connections can be installed with
low-skill labor compared to the skilled welders required to
make top seam welds.

Figure 1.14.5: TOP SEAM WELD

Figure 1.14.7: DELTAGRIP PUNCH

2W PANELS

Screwable Sidelap
Self-drilling screws are used to attach nestable side lap
composite decks. (See figure 1.14.6) The screws can be easily
installed with low-skill labor using screw guns that are readily
available. The screws do not leave burn marks associated
with welding, but the screw points do protrude through the
underside of the steel deck. As a result, screws may not be
acceptable for some architecturally exposed steel decks.

3W PANELS

Self-Drilling Screws
Self-drilling screws are used to attach nestable side lap steel
decks. (See figure 1.14.4) Screws can be easily installed with
low-skill labor using screw guns that are readily available.
Screws do not leave burn marks associated with welding, but
the screw points do protrude through the underside of the
steel deck. As a result, screws may not be acceptable for some
architecturally exposed steel decks.

GENERAL INFORMATION

Side Seam Fastening 1.14

B PANELS
N PANELS
C PANELS
D PANEL

Composite and Non-Composite Deck Catalog May 2014

ACUSTADEK

www.ascsd.com

45

TABLE OF CONTENTS

1.15 Edge Form

Edge Form
Edge form is an integral part of a composite or noncomposite deck installation. The edge form provides
containment of the concrete at the perimeter of the
composite deck-slab system and around openings. Edge
form also provides a screed at the edge to help maintain
slab thickness. Edge forms may be manufactured from
bent plate, cold-formed sheet steel, and hot roll steel
angles or channels. ASC Steel Deck manufactures coldformed sheet steel flashings used for edge forms and other
flashing conditions. Section 1.17 shows typical installation
conditions for common flashing types.
Edge Form Flashings.
Galvanized steel edge form flashings are custom
manufactured by ASC Steel Deck to meet the project
requirements. The flashings are formed from ASTM A653
SS Grade 33 minimum galvanized steel sheets. Flashings
are available in most common structural shapes in 7 gages.
(See figures 1.15.1 and 1.15.2) The standard length flashing
is 10-0, shorter lengths available upon request. The
minimum width of any stiffener or flat cross section is .
For Hat and Channel shapes, the web width must be at least
wider than the flange width.
Design of Edge Form
Edge forms may be rationally designed to support concrete
and construction loads using the methods in the SDI Floor
Deck Design Manual based on engineering mechanics and
confirmatory testing. The SDI edge form table is provided
in figure 1.15.3 provides an easy to use design aid without
the need to detailed calculations for common edge form
conditions.

FLASHING THICKNESS BY GAGE

Gage

Base Steel Thickness

22
20
18
16
14
12
10

0.0290
0.0350
0.0470
0.0590
0.0700
0.1050
0.1350
Figure 1.15.1

34"

34"

MINIMUM FLAT WIDTH

MINIMUM STIFFENER WIDTH

1"
STRIP

FILLER PLATE

34"

ANGLE

ANGLE WITH STIFFENER

ZEE

F+34"

F+34"

HAT

CHANNEL
Figure 1.15.2

46

Composite and Non-Composite Deck Catalog May 2014

www.ascsd.com

TABLE OF CONTENTS

Figure 1.15.3: SDI is the Steel Deck Institute, the author of the following table.

10

11

12

4.00
4.25
4.50
4.75
5.00
5.25
5.50
5.75
6.00
6.25
6.50
6.75
7.00
7.25
7.50
7.75
8.00
8.25
8.50
8.75
9.00
9.25
9.50
9.75
10.00
10.25
10.50
10.75
11.00
11.25
11.50
11.75
12.00

20
20
20
20
20
20
20
20
18
18
18
18
16
16
16
16
14
14
14
14
14
12
12
12
12
12
12
12
12
12
10
10
10

20
20
20
20
20
18
18
18
18
18
16
16
16
16
14
14
14
14
12
12
12
12
12
12
12
12
12
10
10
10
10
10
10

20
20
20
18
18
18
18
16
16
16
16
14
14
14
14
14
12
12
12
12
12
12
12
12
10
10
10
10
10
10
10

20
18
18
18
18
16
16
16
16
14
14
14
14
14
12
12
12
12
12
12
12
12
10
10
10
10
10
10
10

18
18
18
16
16
16
16
14
14
14
14
14
12
12
12
12
12
12
12
12
10
10
10
10
10
10
10

18
16
16
16
16
14
14
14
14
12
12
12
12
12
12
12
12
10
10
10
10
10
10
10
10

16
16
16
14
14
14
14
12
12
12
12
12
12
12
12
10
10
10
10
10
10
10

14
14
14
14
14
12
12
12
12
12
12
12
12
10
10
10
10
10
10
10

12
12
12
12
12
12
12
12
12
12
12
10
10
10
10
10
10
10

12
12
12
12
12
12
12
12
10
10
10
10
10
10
10
10

12
12
12
10
10
10
10
10
10
10
10
10
10

10
10
10
10
10
10
10
10
10

10
10
10
10

3W PANELS

Slab
Depth

GENERAL INFORMATION

Edge Form1.15

2W PANELS
B PANELS

13

N PANELS

25mm Fillet Welds @ 305mm O.C.


Slab
Depth

C PANELS

Pour
Stop

Edge Form Detail

D PANEL

51mm

The above Selection Table is based on the following criteria:

Overhang

1. Normal weight concrete (150 pcf).


2. Horizontal and vertical Deflection is limited to 1/4 maximum for concrete dead load

FD14 Edge Form detail

3. Design stress is limited to 20 ksi for concrete dead load temporarily increased by one-third for the construction live load of 20 psf.
4. Pour Stop Selection Table does not consider the effect of the performance, deflection, or rotation of the pour stop support which may
include both the supporting composite deck and/or the frame.

ACUSTADEK

5. Vertical leg return lip is recommended for type 16 and lighter.


6. This selection is not meant to replace the judgement of experienced Structural Engineers and shall be considered as a reference only.
7. SDI reserves the right to change any information in this section without notice.

www.ascsd.com

Composite and Non-Composite Deck Catalog May 2014

47

TABLE OF CONTENTS

1.16 Accessories

ASC Steel Deck offers a variety of accessories to complement


our steel deck offer. These include flashings, sump pans,
weld washers, profile cut top (small void) and bottom (large
void) neoprene foam, and galvanized steel closures.
When accessories are called for in the specifications,
the location must be clearly shown on the structural and
architectural drawings. Specifications that call for the use
of profile cut closures where walls meet the metal deck
may lead to unnecessary construction costs if they are only
needed at exterior walls or specific interior locations.
B36 DECK NEOPRENE AND METAL CLOSURES

Profile Cut Neoprene Closures.


Neoprene closures may be used on the top and bottom
of the steel deck to reduce vapor, moisture, and air from
infiltrating into the building roof or floor assembly. These
are die-cut from black closed cell neoprene foam. The
foam is manufactured in accordance with ASTM D-1056
and passes the FM VSS No. 302, UL 94HBF, and UL 94
HF1 flammability tests.
Profile Cut Metal Closures.
Metal closures may be used to control animal nesting
within the building structure. Metal closures may be used
in combination with neoprene closures. Metal closures
with calking can also be used to reduce noise infiltration
as part of an acoustically engineered system. The metal
closures are stamped out of 22 gage galvanized sheet steel.

B36 Large Neoprene

B36 Large Metal

2W NEOPRENE AND METAL CLOSURES

Figure 1.16.1

N32 DECK NEOPRENE AND METAL CLOSURES

2W Neoprene Top

2W Metal Bottom
N32 Large Neoprene

Figure 1.16.4

N32 Large Metal

3W NEOPRENE AND METAL CLOSURES

Figure 1.16.2

Weld Washers
14 gauge x 38 diameter hole for welded attachment of C1.4-32.
Variable Gauge x 38 diameter hole for welded attachment of
C1.9-32. Weld washers are for use with 26 and 24 gage C1.432 and C1.9-32 only. Do not use weld washers on 22 gage of
Raised Edge Weld Washer
heavier steel decks.

3W Neoprene Top

3W Metal Bottom
Figure 1.16.5

1
3/4 Weld Washer
Curved

14 Gage x 38 dia.
hole for welded
attachment of
C1.4-32

DEEP DECK NEOPRENE CLOSURES

14 gauge X 3/8 dia. hole for welded attachment of CF 7/8.


RD39

Raised Edge Weld Washers

14 Gage x 38 dia.
hole for welded
attachment of
C0.9-32

4.5D Neoprene

Figure 1.16.3

48

Composite and Non-Composite Deck Catalog May 2014

6D Neoprene

7.5D Neoprene

Figure 1.16.6

www.ascsd.com

TABLE OF CONTENTS

2W PANELS

Minimum Welded Wire


or
Rebar when Specified

3W PANELS

Details
Composite deck-slab systems are not complete without
edge form and flashings to contain the concrete during the
pour. These common details are an important part of the
system. Edge forms provide both concrete containment and
establish one point of depth control for the concrete.

GENERAL INFORMATION

Typical Details 1.17

Cell Closure
Edge Form

eq
eq
B PANELS

Figure 1.17.1: TYPICAL PLACEMENT OF TEMPERATURE


& SHRINKAGE REINFORCEMENT

Edge Form

N PANELS

Figure 1.17.3: SINGLE PIECE EDGE FROM PERPENDICULAR


TO DECK ON WIDE FLANGE BEAM

Edge Form

C PANELS

Cell Closure
D PANEL

Figure 1.17.2: SINGLE PIECE EDGE FROM PARALLEL


TO DECK ON WIDE FLANGE BEAM

Figure 1.17.4: TWO PIECE EDGE FORM WITH


DECK CANTILEVER ON WIDE FLANGE BEAM

ACUSTADEK

www.ascsd.com

Composite and Non-Composite Deck Catalog May 2014

49

TABLE OF CONTENTS

1.17 Typical Details

Field Cut Deck

Figure 1.17.5: DECK PARALLEL TO WIDE FLANGE BEAM

Figure 1.17.8: DECK PARALLEL TO WIDE FLANGE BEAM CUT


WITH ZEE FLASHING TO ACCOMMODATE DECK MODULE

Field Cut Deck

Cell Closure

Figure 1.17.6: DECK PARALLEL TO WIDE FLANGE BEAM CUT


TO ACCOMMODATE DECK MODULE

Filler Plates

Figure 1.17.9: DECK TRANSITION ON WIDE FLANGE BEAM

or

Figure 1.17.7: DECK PARALLEL TO WIDE FLANGE


BEAM WITH FILLER PLATES

50

Z Closure

Composite and Non-Composite Deck Catalog May 2014

Figure 1.17.10: DECK PERPENDICULAR


TO WIDE FLANGE BEAM

www.ascsd.com

TABLE OF CONTENTS

Edge Form

Hat or Channel
Section

GENERAL INFORMATION

Typical Details 1.17

3W PANELS

Figure 1.17.11: CONCRETE OR CMU WALL LEGER


DECK PERPENDICULAR

2W PANELS

Figure 1.17.14: SINGLE PIECE EDGE FROM PARALLEL TO


DECK ON OPEN WEB JOIST GIRDER

Edge Form

B PANELS

Cell Closure

N PANELS

Figure 1.17.15: TWO PIECE EDGE FORM WITH DECK


CANTILEVER ON WIDE FLANGE BEAM

C PANELS

Figure 1.17.12: CONCRETE OR CMU WALL LEGER


DECK PARALLEL

D PANEL

Figure 1.17.13: CONCRETE OR CMU WALL


WITH EMBED PERPENDICULAR

www.ascsd.com

ACUSTADEK

HAT SECTION
ONLY REQUIRED
AT GIRDERS THAT
ARE AXIAL COLLECTORS
FOR DIAPHRAGM

Figure 1.17.16: DECK ON OPEN WEB STEEL


JOISTS AND OPEN WEB STEEL JOIST GIRDER

Composite and Non-Composite Deck Catalog May 2014

51

TABLE OF CONTENTS

1.17 Typical Details

Column Flashings
Columns may require deck support angles depending on
web support. Smaller columns often do not require deck
support angles because there are no unsupported webs
as shown in Figure 1.17.17. Large columns will create a
condition in which one or more webs are unsupported, as
shown in Figure 1.17.18. When the webs are unsupported,
deck support angles are required to limit localized

deflections during concrete placement. The Detail in


Figure 1.17.18 is a common example of how deck may
be supported when required. Using the thinnest support
angles practical, when installed as shown, makes fitting
and attaching the deck easier.

DECK NOT SHOWN


FOR CLARITY

DECK NOT SHOWN


FOR CLARITY

Deck
Support
Angles

Deck Support
Required
When These Webs
are Unsupported
by Beams

Deck Support
Not Required
When These Webs
are Supported
by Beams

Deck
Support
Angles

Figure 1.17.17: COLUMN DETAIL NOT REQUIRING


DECK SUPPORT ANGLES

52

Composite and Non-Composite Deck Catalog May 2014

Figure 1.17.18: COLUMN DETAIL REQUIRING


DECK SUPPORT ANGLES

www.ascsd.com

TABLE OF CONTENTS

Composite Deck-Slab 1.18


Tables General Requirements

2W PANELS
B PANELS
ACUSTADEK

Composite and Non-Composite Deck Catalog May 2014

D PANEL

Concrete and minimum reinforcing


1. The minimum 28-day compressive strength for
structural concrete shall be 3,000 psi (20.68 MPa).
The appropriate concrete density (normal weight or
structural lightweight) is indicated in the tables.

C PANELS

Deck as a form
1. Shoring spans are based on the load combinations and
bending strength requirements of ANSI/SDI C-2011, which
include the weight of the deck. The loading includes
the weight of the deck, concrete, and 20psf uniform
construction load, or 150 lbs/ft line load at mid span. In
addition to the loads in accordance with ANSI/SDI C-2011,
3psf is added for normal weight concrete, and 2 psf is
added for light weight concrete to account for pounding
due to deck deflection between supporting members.
2. The theoretical deflection is limited to L/180, but
not to exceed 3/4 inch for the weight of concrete
and steel deck only.
3. Reactions at supports shall not be exceeded. The shoring
span may be limited by the reactions at supports in some
conditions. For support reactions exceeding the reaction
tables, the reactions shall be based on the web crippling
of the steel deck using the flat width (h), angle to support
() and bend radius (r) presented in the reactions tables
in accordance with the provisions of AISI S100-2007
including the 2010 supplement.
4. Conditions exceeding the scope of the tables,
such as cantilever spans, may be determined in
accordance with ANSI/SDI C-2011 and submitted
to the building official for approval.

N PANELS

www.ascsd.com

sg
Minimum section modulus for gross
section
r
radius of gyration
Ae
Effective are for compression
se-
Negative effective section modulus
se+
Positive effective section modulus
Ie+
Positive effective moment of inertia
Ie-
Negative effective moment of inertia
I+
Positive effective moment of inertia

for determining deflection
Negative effective moment of inertia
I-

for determining deflection
11. Definition of symbols for reactions
h
Flat width of web
R/
ASD available reaction capacity

at support based on web crippling
R
LRFD available reaction capacity at

support based on web crippling
r
bend radius of web/flange transition

angle relative to the support of the web
12. Definition for headed shear stud anchors
Qn
Nominal shear capacity for one welded

headed shear studs anchor
Qn/
ASD available shear capacity for one

welded headed shear studs anchor
Qn
LRFD available shear capacity for one

welded headed shear studs anchor

3W PANELS

General Notes
1. The general notes apply to the entire catalog.
2. Composite steel deck is manufactured from galvanized
steel conforming to ASTM A653 SS grade 50 or bare steel
conforming to ASTM A1008 SS grade 50.
3. The concrete slabs depth in the tables is measured for the
bottom of deck to the top of concrete.
4. The vertical load span is the clear span between
supporting members.
5. Superimposed load is the load that can be applied to the
composite deck in addition to the weight of the steel deck
and concrete.
6. No uniform service load, based on an L/360 deflection
limit, is shown when the load is greater than the allowable
superimposed load.
7. For composite steel deck assemblies that exceed the
scope of the table, the performance may be determined in
accordance with ANSI/SDI C-2011.
a. For 2WH-36 and 2WHF-36 the embossment shape
is Type 1 with an embossment factor,
K = 1.0, reference Eq. A2-8 in ANSI/SDI C-2011
b. For 3WH-36 and 3WHF-36 the embossment shape
is Type 2 with an embossment factor,
K = 1.0, reference Eq. A2-8 in ANSI/SDI C-2011
c. For BH-36 and BHF-36 the embossment shape is
Type 1 with an embossment factor,
K = 1.0, reference Eq. A2-8 in ANSI/SDI C-2011
d. For NH-32 and NHF-32 the embossment shape is
Type 2 with an embossment factor,
K = 1.0, reference Eq. A2-8 in ANSI/SDI C-2011
8. Load tables are based on non-cellular version of profile.
The addition of the pan (bottom plate) of cellular
deck increases steel area and inherently increases the
performance of the composite deck assembly. Using noncellular design values in tables is therefore conservative.
9. Definition of symbols for composite deck
As
Area of reinforcing steel
Icr
Cracked moment of inertia
Iu
Un-cracked moment of inertia
(Icr+Iu)/2 Moment of inertia for determining

deflection under service load
L
Vertical load clear span
Mno/ ASD available flexural moment
Vn/ ASD available vertical shear
Mno LRFD available flexural moment
Vn
LRFD available vertical shear
Sn
LRFD available diaphragm shear
PAF
Power actuated fastener
W/
ASD available superimposed load capacity
W
LRFD available superimposed load

capacity
10. Definition of symbols for panel properties
Ag
Gross Area of steel deck
t
Design base steel thickness of steel deck
Fy
Yield strength of steel
Fu
Tensile strength of steel
Ig
Moment of inertia of gross section
yb
Distance form extreme bottom fiber to

neutral axis of gross or effective section

GENERAL INFORMATION

53

TABLE OF CONTENTS

1.18 Composite Deck-Slab


Tables General Requirements
2. Minimum reinforcing may be provided by reinforcing
steel, welded wire fabric, or fibers in accordance with of
the following.
a. Minimum steel reinforcing shall be equal to 0.00075
times the area of the concrete above the steel deck,
but not less than 6 x 6 W1.4 x W1.4 welded wire
fabric with a 60,000psi minimum tensile strength
complying with ASTM A1064.
b. Concrete fibers in accordance with ANSI/SDI
C-2011 section 13.a.1 or 13.a.2.
Attachment of composite
steel deck to supports
1. To develop the shear capacity in the tables, the deck
shall be attached to the supports with the specified
fastener pattern.
2. Spacing of welds or fasteners running parallel with the
deck shall not exceed 36 inches on center.
3. Power actuated fasteners shall be installed per
manufactures instructions
4. Welds and fasteners to the supports shall be as follows:
a. Welds
i. Welds shall be have a minimum of
60ksi filler metal. For shielded metal arc
welding, a minimum E60xx electrode
should be used.
ii. Arc spot welds shall have a minimum
inch effective diameter and not less than a
5/8 inch visible diameter
iii. Arc seam welds shall have a minimum 38
inch x 1 inch effective size, and may be
substituted for inch effective diameter arc
spot welds
b. Power actuated fasteners (PAF) in support steel .25
inch thick shall be.
i. Hilti X-ENP19
ii. Pneutek K64
iii. Pneutek K66
c. Power actuated fasteners (PAF) in support steel
0.109 inch thick shall be.
i. Hilti X-EDN19 & X-EDNK22
ii. Pneutek K63
iii. Pneutek K61
d. Self-drilling screws in support steel .034 inch thick
shall be
i. #12 Self Drilling-Screw in accordance with
SAE J78
e. Minimum Edge Distance
i. Steel decks may be butted at supports or end
lapped. The standard end lap is a 2-inch
overlap with a tolerance of +/-1/2 inch.
The minimum 1-1/2 inch overlap (2-inch
standard less -inch tolerance) is required.
Overlaps greater than 2-1/2 inches do not
affect diaphragm performance, but is more
difficult to install.
ii. The minimum edge distance for self-drilling
screws and power driven fasteners (pins/
nails) is inch.

54

5. The minimum edge distance for welds is inch


measured from the center of the arc spot weld and the
center of the end radius of the arc seam weld.

>emin

Butted Tight or Gap

>emin

Figure 1.18.1: BUTTED DECK CONDITION

2 +- 1/2
unlimitted

>emin

>emin

Figure 1.18.2: END LAPPED DECK CONDITION

Side seam attachment between deck panels


1. The minimum side seam attachment is a button
punch at 36 inches on center.
2. Triple Button Punches, DeltaGrip side seam
connections, arc top seam welds, or self-drilling
screws may be substituted on a one to one basis for
button punches.
3. The minimum edge distance for side lap screws is 1.5
times the nominal diameter of the screw.
Diaphragm shear attached with arc spot
welds, power actuated fasteners, or selfdrilling screws.
1. For composite steel deck assemblies that exceed the
scope of the tables, the diaphragm shear performance
may be determined in accordance with the SDI
DDM03 referenced in ANSI/SDI C-2011
2. Diaphragms with concrete fill have a flexibility factor,
f < 0.5 micro inches per lb equal to a shear stiffness,
G > 2000kip/inch
3. Spacing of welds or fasteners transferring shear between
the composite steel deck and supporting structures shall be
based on the shear demand and the weld or fastener shear
resistance.
fastener spacing (ft) = weld or fastener capacity (lbs) /
shear demand (lbs/ft)
4. Resistance and safety factors for diaphragm shear, = 0.5

Composite and Non-Composite Deck Catalog May 2014

www.ascsd.com

TABLE OF CONTENTS

Composite Deck-Slab 1.18


Tables General Requirements
11. See figure 1.18.4 for typical details

Reinforcing Mesh
or Bar
Reinforcing Mesh
or Bar
Concrete
Thickness
Concrete
Thickness
Deck
Height

Deck Height

Concrete
Thickness
Concrete
Thickness
Deck Height
Deck Height

B PANELS

Shear
Steel
Stud
Deck
Shear
Steel
Stud
Deck
Deck May Extend
as Shown
Deck May Extend
as Shown
Deck Parallel to Beam
Figure 1.18.4

D PANEL

Shear Capacity1
LRFD
Qn

2WH-36, 2WHF-36, & 2WHF-36A,


3WH-36, 3WHF-36, & 3WHF-36A

10.3 kips

15.5 kips

BH-36, BHF-36, & BHF-36A


NH-32, NHF-32, & NHF-32A

8.8 kips

13.2 kips

ACUSTADEK

ASD
Qn/R

145 pcf Normal Weight Concrete and 110 pcf Light Weight Concrete
Figure 1.18.3

www.ascsd.com

Composite and Non-Composite Deck Catalog May 2014

C PANELS

4" Steel Headed Stud Anchors

N PANELS

12. For diaphragm shear of composite steel deck assemblies


attached with welded shear studs that exceed the scope
of the tables, the diaphragm shear may be determined in
accordance with the provision of ACI 318 and AISC 360
as follows.
a. The diaphragm shear shall be the lesser of the
capacity of the reinforced concrete and the
capacity of the welded shear studs to transfer
the shear from the supporting member to the
reinforced concrete section.
b. Reinforced concrete shear shall be determined in
accordance with the requirements of ACI 318 using
the concrete thickness above the steel deck.
c. The welded shear stud strength shall be determined
in accordance with ASIC 360.

DECK TYPES

2W PANELS

Shear
Steel
Stud
Deck
Shear
Steel
Stud
Deck
Deck Parallel to Beam
Reinforcing Mesh
or Bar
Reinforcing Mesh
or Bar

3W PANELS

Diaphragm shear with welded headed shear


studs anchors
1. Concrete shear reinforcing steel shall be provided that
meets the minimum specified reinforcing area, (As), in
the table based on suggested welded wire reinforcing
size. Reinforcing shall have minimum yield strength of
60,000psi and meet the requirements of ACI 318-08 for
standard reinforcing bars or WRI standard welded wire
reinforcement.
2. To achieve tabulated diaphragm shears, the welded
stud shear connectors are only required at locations in
which diaphragm shear is being transferred between
the composite deck slab and supporting members.
Intermediate support members may be attached with
welds, screws or PAFs (power actuated fasteners)
3. Intermediate ribs of the steel deck not attached with
welded stud shear connectors shall be fastened to the
supporting member with arc spot welds, self-drilling
screws, or power actuated fasteners.
4. The welded stud shear connector strength assumes the
weak position in the deck flute. Reference AISC 360-05
Commentary and figure C-I3.4.
5. Tabular values for shear strength of concrete diaphragm
above deck is in accordance with ACI 318-08 based on a
resistance factor = 0.75. See ACI 318-08 section 9.3.4
for additional requirements to be considered in seismic
design.
6. Welded stud shear connectors shall extend 1 above
the top of the steel deck and shall have a minimum of
concrete cover above the top of the installed connector.
Reference AISC 360-05 Section I3.2c(b).
7. The supporting member flange shall not be less than
0.3 inches thick unless the welded stud shear connector
is welded over the web of the supporting member.
Reference AISC 360-05 I3.2d(6)
8. The maximum center-to-center spacing of welded stud
shear connectors shall not exceed 8 times the depth of
concrete above the deck or 36 per AISC 360-05 Section
I3.2d(6).
9. Concrete reinforcement details shall be in accordance with
ACI318-08.
10. For local shear transfer in the field of the diaphragm,
inch diameter welded stud shear connectors shall
be determined in accordance with AISC 360-05.
The following shear capacities are for 2 inches of
concrete cover above the steel deck and may be used
conservatively for all thicknesses greater than 2 inches.

GENERAL INFORMATION

55

TABLE OF CONTENTS

2.1 3WH-36
3"

12"
3"

36"

36/4

3"

3WH-36 Profile

36/4 Attachment Patterns

3W Series Embossment
Panel Properties

Gage

Weight

22
21
20
19
18
16

w
psf
1.70
1.92
2.03
2.40
2.68
3.35

Compression
Gage
22
21
20
19
18
16

Area
Ae
in2/ft
0.289
0.355
0.389
0.516
0.603
0.808

Base Metal
Thickness Yield Strength
t
in
0.029
0.033
0.035
0.042
0.047
0.059

Tensile
Strength

Area

Fu
ksi
65
65
65
65
65
65

Ag
in2/ft
0.474
0.539
0.571
0.685
0.766
0.959

Fy
ksi
50
50
50
50
50
50

Effective Section Modulus at Fy


Bending
Distance to
Section
N.A. from
Section
Modulus
Bottom
Modulus
Se+
yb
Sein3/ft
in
in3/ft
0.368
1.35
0.400
0.449
1.39
0.477
0.487
1.41
0.516
0.622
1.45
0.627
0.704
1.46
0.702
0.880
1.47
0.880

Gage
22
21
20
19
18
16

56

Condition

1"

End
264
Interior
473
End
339
Interior
605
End
380
Interior
677
End
538
Interior
956
End
667
Interior
1184
End
1028
Interior
1821
Web Crippling Constraints

329
571
420
726
470
810
661
1136
815
1399
1244
2132

421
710
535
898
597
999
834
1390
1024
1704
1549
2571
h=3.5"

Ig
in4/ft
0.687
0.783
0.830
0.997
1.113
1.397

yb
in
1.45
1.46
1.46
1.46
1.46
1.47

Sg
in3/ft
0.473
0.538
0.570
0.681
0.761
0.950

Radius of
Gyration
r
in
1.205
1.205
1.025
1.206
1.206
1.207

Effective Moment of Inertia for Deflection


Distance to
N.A. from
Bottom
yb
in
1.56
1.53
1.52
1.47
1.47
1.47

Reactions at Supports (plf) Based on Web Crippling


Allowable (Rn/)
1.5"
2"

Gross Section Properties


Distance to
Moment of
N.A. from
Section
Inertia
Bottom
Modulus

Moment of
Inertia
Ie+
in4/ft
0.677
0.783
0.830
0.997
1.113
1.397

Bearing Length of Webs


3"

1"

492
816
624
1029
694
1144
967
1585
1185
1938
1783
2908

404
704
519
900
581
1007
824
1423
1021
1761
1572
2709
r=0.125"

Composite and Non-Composite Deck Catalog May 2014

Moment of
Inertia
I ein4/ft
0.667
0.773
0.823
0.993
1.113
1.397

Uniform Load Only


Id = (2Ie+Ig)/3
I+
in4/ft
0.680
0.783
0.830
0.997
1.113
1.397

Factored (Rn)
1.5"
2"
580
961
739
1219
824
1357
1155
1895
1421
2327
2156
3526

644
1056
819
1335
913
1486
1276
2068
1567
2535
2370
3825
=54.4

Iin4/ft
0.673
0.777
0.826
0.994
1.113
1.397

3"
753
1214
954
1531
1062
1701
1480
2358
1813
2883
2728
4326

www.ascsd.com

TABLE OF CONTENTS

3"

12"
3"

36/4

3"

36"

GENERAL INFORMATION

3WHF-36 2.2

36/4 Attachment Patterns

3WHF-36 Profile

Gage

Gage

Area
Ag
in2/ft
1.027
1.168
1.322
1.235
1.376
1.529
1.430
1.571
1.725

Effective Section Modulus at Fy


Bending
Distance to
N.A. from
Bottom
yb
in
0.78
0.70
0.62
0.95
0.86
0.79
1.05
0.97
0.90

Section
Modulus
Sein3/ft
0.522
0.571
0.598
0.655
0.762
0.797
0.785
0.940
0.982

Effective Moment of Inertia for Deflection


Distance to
N.A. from
Bottom
yb
in
1.56
1.41
1.24
1.62
1.50
1.36
1.65
1.55
1.43

Moment of
Inertia
Ie +
in4/ft
1.370
1.453
1.529
1.883
2.005
2.115
2.314
2.464
2.604

Moment of
Inertia
I ein4/ft
1.021
1.183
1.302
1.329
1.488
1.639
1.609
1.764
1.939

Uniform Load Only


Id = (2Ie+Ig)/3
I+
in4/ft
1.383
1.468
1.544
1.858
1.977
2.086
2.264
2.410
2.546

Iin4/ft
1.150
1.287
1.392
1.489
1.633
1.769
1.794
1.943
2.103

C PANELS

Section
Modulus
Se+
in3/ft
0.547
0.556
0.557
0.824
0.838
0.850
1.076
1.095
1.111

Radius of
Gyration
r
in
1.171
1.132
1.091
1.210
1.182
1.151
1.230
1.210
1.187

N PANELS

20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16

Area
Ae
in2/ft
0.617
0.683
0.774
0.844
0.910
1.002
1.056
1.123
1.215

Tensile
Strength
Fu
ksi
65
65
65
65
65
65
65
65
65

B PANELS

Compression

Base Metal
Thickness Yield Strength
t
Fy
in
ksi
0.035 / 0.036
50
0.035 / 0.047
50
0.035 / 0.059
50
0.047 / 0.036
50
0.047 / 0.047
50
0.047 / 0.059
50
0.059 / 0.036
50
0.059 / 0.047
50
0.059 / 0.059
50

2W PANELS

20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16

Weight
w
psf
3.63
4.10
4.62
4.28
4.76
5.28
4.95
5.43
5.95

Gross Section Properties


Distance to
Moment of
N.A. from
Section
Inertia
Bottom
Modulus
Ig
yb
Sg
in4/ft
in
in3/ft
1.409
0.85
0.635
1.497
0.76
0.646
1.574
0.69
0.655
1.807
0.97
0.855
1.923
0.88
0.869
2.028
0.81
0.882
2.164
1.05
1.057
2.302
0.97
1.076
2.429
0.90
1.093

3W PANELS

Panel Properties

D PANEL
ACUSTADEK

www.ascsd.com

Composite and Non-Composite Deck Catalog May 2014

57

TABLE OF CONTENTS

2.3 3WHF-36 Cellular Composite Deck


Normal Weight Concrete (145 pcf)
Maximum Unshored Spans

3WHF-36 Cellular Shoring Table


Total Slab Depth
(in)

6 1/2
1 Hour
Fire Rating

7 1/2
2 Hour
Fire Rating

Volume
cy/100sf

1.080

1.389

1.543

1.852

8 1/4
3 Hour
Fire Rating

2.083

Gage
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16

145 pcf Normal Weight Concrete


Maximum Unshored Span
Slab and Deck
psf
Single
Double
45.9
12' - 2"
12' - 4"
46.4
12' - 3"
12' - 10"
46.9
12' - 3"
13' - 1"
46.6
13' - 10"
13' - 8"
47.0
14' - 1"
14' - 9"
47.6
14' - 2"
15' - 0"
47.2
14' - 6"
14' - 11"
47.7
14' - 9"
16' - 3"
48.2
14' - 10"
16' - 7"
58.0
11' - 2"
11' - 4"
58.5
11' - 3"
11' - 10"
59.0
11' - 2"
12' - 1"
58.7
13' - 2"
12' - 8"
59.1
13' - 4"
13' - 7"
59.7
13' - 5"
13' - 11"
59.3
13' - 9"
13' - 10"
59.8
13' - 11"
15' - 1"
60.3
14' - 1"
15' - 4"
64.0
10' - 9"
10' - 11"
64.5
10' - 9"
11' - 5"
65.0
10' - 9"
11' - 8"
64.7
12' - 10"
12' - 2"
65.2
13' - 0"
13' - 2"
65.7
13' - 2"
13' - 5"
65.4
13' - 5"
13' - 4"
65.8
13' - 8"
14' - 6"
66.4
13' - 9"
14' - 10"
76.1
10' - 0"
10' - 3"
76.6
10' - 1"
10' - 8"
77.1
10' - 1"
10' - 11"
76.8
12' - 4"
11' - 5"
77.3
12' - 6"
12' - 4"
77.8
12' - 8"
12' - 7"
77.5
12' - 11"
12' - 6"
77.9
13' - 1"
13' - 8"
78.4
13' - 3"
13' - 11"
85.2
9' - 7"
9' - 10"
85.7
9' - 7"
10' - 3"
86.2
9' - 7"
10' - 5"
85.8
12' - 0"
10' - 11"
86.3
12' - 1"
11' - 10"
86.8
12' - 2"
12' - 0"
86.5
12' - 7"
12' - 0"
87.0
12' - 9"
13' - 1"
87.5
12' - 11"
13' - 4"

Triple
13' - 0"
13' - 1"
13' - 0"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
12' - 0"
12' - 1"
12' - 0"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
11' - 7"
11' - 8"
11' - 7"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
10' - 10"
10' - 11"
10' - 11"
13' - 3"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
10' - 5"
10' - 5"
10' - 5"
12' - 8"
12' - 9"
12' - 10"
13' - 4"
13' - 4"
13' - 4"

Shaded area the span is governed by maximum deck panel length of 40 feet; 20 feet for double span, 13 feet 4 inches for triple span.

58

Composite and Non-Composite Deck Catalog May 2014

www.ascsd.com

TABLE OF CONTENTS

3WHF-36 Cellular Composite Deck 2.3


Light Weight Concrete (110 pcf)
Maximum Unshored Spans

Volume
cy/100sf

1.080

1 Hour
Fire Rating

1.389

2 Hour
Fire Rating

1.466

3 Hour
Fire Rating

1.755

D PANEL

7 3/16

C PANELS

6 1/4

N PANELS

1.235

Triple
14' - 3"
14' - 3"
14' - 3"
14' - 3"
14' - 3"
14' - 3"
14' - 3"
14' - 3"
14' - 3"
13' - 8"
13' - 9"
13' - 8"
14' - 3"
14' - 3"
14' - 3"
14' - 3"
14' - 3"
14' - 3"
13' - 2"
13' - 3"
13' - 3"
14' - 3"
14' - 3"
14' - 3"
14' - 3"
14' - 3"
14' - 3"
13' - 0"
13' - 1"
13' - 0"
14' - 3"
14' - 3"
14' - 3"
14' - 3"
14' - 3"
14' - 3"
12' - 3"
12' - 4"
12' - 3"
14' - 3"
14' - 3"
14' - 3"
14' - 3"
14' - 3"
14' - 3"

B PANELS

5 1/2

ACUSTADEK

Gage
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16

110 pcf Light Weight Concrete


Maximum Unshored Span
Slab and Deck
psf
Single
Double
35.7
13' - 6"
13' - 5"
36.2
13' - 7"
14' - 0"
36.7
13' - 6"
14' - 3"
36.4
14' - 9"
15' - 0"
36.8
15' - 0"
16' - 1"
37.4
15' - 1"
16' - 5"
37.0
15' - 6"
16' - 4"
37.5
15' - 8"
17' - 10"
38.0
15' - 10"
18' - 2"
40.3
12' - 11"
12' - 11"
40.8
13' - 0"
13' - 6"
41.3
12' - 11"
13' - 9"
40.9
14' - 4"
14' - 5"
41.4
14' - 7"
15' - 6"
41.9
14' - 8"
15' - 9"
41.6
15' - 0"
15' - 8"
42.1
15' - 3"
17' - 1"
42.6
15' - 5"
17' - 5"
44.9
12' - 5"
12' - 6"
45.4
12' - 6"
13' - 0"
45.9
12' - 5"
13' - 3"
45.5
14' - 0"
13' - 11"
46.0
14' - 2"
14' - 11"
46.5
14' - 4"
15' - 3"
46.2
14' - 8"
15' - 2"
46.7
14' - 10"
16' - 6"
47.2
15' - 0"
16' - 10"
47.2
12' - 2"
12' - 3"
47.6
12' - 3"
12' - 9"
48.2
12' - 2"
13' - 0"
47.8
13' - 10"
13' - 8"
48.3
14' - 0"
14' - 8"
48.8
14' - 2"
15' - 0"
48.5
14' - 6"
14' - 11"
49.0
14' - 8"
16' - 3"
49.5
14' - 10"
16' - 7"
55.8
11' - 5"
11' - 7"
56.2
11' - 6"
12' - 1"
56.8
11' - 5"
12' - 4"
56.4
13' - 4"
12' - 11"
56.9
13' - 6"
13' - 11"
57.4
13' - 8"
14' - 2"
57.1
13' - 11"
14' - 1"
57.6
14' - 2"
15' - 4"
58.1
14' - 4"
15' - 8"

2W PANELS

Total Slab Depth


(in)

3W PANELS

3WHF-36 Cellular Shoring Table

Shaded area the span is governed by maximum deck panel length of 40 feet; 20 feet for double span, 13 feet 4 inches for triple span.

www.ascsd.com

GENERAL INFORMATION

Composite and Non-Composite Deck Catalog May 2014

59

TABLE OF CONTENTS

2.4 3WH-36 Composite Deck


5" Total Slab Depth
Normal Weight Concrete (145 pcf)
Concrete Volume 1.080yd3/100ft2

Gage
22
21
20
GA

22

Single
9' - 8"
10' - 11"
11' - 5"

Maximum Unshored Span (in)


Triple
Gage
11' - 3"
19
12' - 3"
18
12' - 8"
16

Double
10' - 10"
11' - 10"
12' - 3"

Vertical Load Span (in)

8'-0"

8'-6"

ASD, W/
LRFD, W
L/360

266
426
-

232
371
-

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

9'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


2366 2341 2318 2308 2290 2273
2177 2163 2150 2149 2138 2129
2162 2149 2137 2137 2127 2118
2149 2136 2125 2125 2116 2107

ASD, W/
LRFD, W
L/360
21

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

64
103
-

58
92
-

52
83
-

Attachment Pattern
2243 2230 2226
2112 2104 2106
2101 2094 2096
2092 2085 2087

2215
2099
2090
2081

2205
2093
2084
2076

2195
2087
2079
2071

2186
2082
2074
2066

2178
2077
2069
2062

Mno/= 30.1 kip-in/ft


Mno= 46.0 kip-in/ft

302
484
-

8'-6"

ASD, W/
LRFD, W
L/360

320
513
-

280
448
-

36/4
2305
2147
2135
2124

104
166
-

94
150
-

84
135
-

76
122
-

69
110
-

62
99
-

Attachment Pattern
2288 2273 2270
2137 2129 2131
2126 2117 2120
2115 2108 2111

2257
2123
2113
2104

2245
2116
2106
2098

2234
2109
2100
2092

2223
2103
2094
2086

2213
2097
2089
2081

Mno/= 33.8 kip-in/ft


Mno= 51.7 kip-in/ft

Icr = 41.4 in4/ft


Iu = 100.9 in4/ft
9'-0"

Vn/ = 3.29 kip/ft


Vn = 4.76 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


2429 2400 2373 2364 2342 2322
2212 2195 2180 2181 2168 2157
2195 2180 2166 2167 2155 2144
2180 2166 2153 2155 2143 2133

Vn/ = 3.88 kip/ft


Vn = 5.57 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

ASD & LRFD - Superimposed Load, W (psf)


246 217 193 172 153 138 124
394 348 309 275 246 220 198
-

LRFD - Diaphragm Shear, Sn (plf / ft)


2461 2430 2402 2392 2369 2348
2230 2212 2196 2197 2184 2172
2212 2195 2180 2183 2170 2158
2197 2181 2167 2170 2158 2147

Concrete + Deck = 45.2 psf


(Icr+Iu)/2 = 72.58 in4/ft

60

72
115
-

ASD & LRFD - Superimposed Load, W (psf)


264 232 205 181 161 144 129 116
423 371 327 290 258 231 206 185
-

8'-0"

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

80
128
-

8'-6"

Vertical Load Span (in)

Triple
14' - 0"
14' - 4"
15' - 2"

89
143
-

8'-0"

Concrete + Deck = 45.1 psf


(Icr+Iu)/2 = 71.18 in4/ft

20

36/4
2257
2120
2109
2099

Icr = 37.5 in4/ft


Iu = 99.0 in4/ft
9'-0"

Double
13' - 6"
14' - 3"
15' - 11"

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

ASD & LRFD - Superimposed Load, W (psf)


203 179 158 140 125 111 100
325 286 253 224 200 178 159
-

Concrete + Deck = 44.8 psf


(Icr+Iu)/2 = 68.26 in4/ft
Vertical Load Span (in)

Single
11' - 11"
12' - 3"
12' - 11"

36/4
2329
2161
2148
2137

Icr = 43.3 in4/ft


Iu = 101.9 in4/ft

Composite and Non-Composite Deck Catalog May 2014

111
178
-

100
160
-

91
145
-

82
131
-

74
118
-

67
107
-

Attachment Pattern
2311 2295 2293
2150 2141 2144
2138 2129 2133
2128 2119 2123

2278
2136
2125
2116

2265
2128
2118
2109

2253
2121
2111
2102

2242
2114
2105
2096

2232
2108
2099
2091

Mno/= 35.6 kip-in/ft


Mno= 54.4 kip-in/ft

Vn/ = 4.06 kip/ft


Vn = 6.05 kip/ft

www.ascsd.com

TABLE OF CONTENTS

5" Total Slab Depth


Normal Weight Concrete (145 pcf)

Concrete Volume 1.080yd3/100ft2

Vertical Load Span (in)


ASD, W/
LRFD, W
L/360
Arc Spot Weld 1/2" Effective Dia
PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

8'-6"

382
611
-

ASD & LRFD - Superimposed Load, W (psf)


334 294 261 232 207 186 167 151
535 471 417 371 331 297 267 241
-

9'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


2577 2538 2504 2496 2467 2441
2294 2272 2253 2258 2241 2226
2273 2253 2234 2240 2224 2209
2257 2237 2220 2226 2211 2197

18

84
135
-

Attachment Pattern
2396 2376 2375
2199 2187 2194
2184 2173 2180
2173 2163 2170

2357
2183
2170
2160

2341
2173
2161
2151

2326
2164
2152
2143

2312
2156
2144
2135

2299
2148
2137
2128

Mno/= 41.7 kip-in/ft


Mno= 63.9 kip-in/ft

424
678
-

ASD & LRFD - Superimposed Load, W (psf)


372 328 291 259 232 208 187 169
594 524 465 414 371 333 300 271
-

9'-0"

8'-6"

ASD, W/
LRFD, W
L/360

522
835
-

458
733
-

36/4
2483
2250
2233
2221

153
245
-

139
223
-

127
202
-

115
184
-

105
168
-

96
154
-

Attachment Pattern
2459 2436 2436
2236 2222 2231
2220 2207 2216
2208 2196 2206

2416
2219
2205
2195

2398
2208
2194
2184

2381
2198
2184
2175

2365
2188
2175
2166

2350
2179
2166
2158

Mno/= 46.0 kip-in/ft


Mno= 70.4 kip-in/ft

Icr = 53.5 in4/ft


Iu = 107.5 in4/ft
9'-0"

Vn/ = 4.06 kip/ft


Vn = 6.09 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

ASD & LRFD - Superimposed Load, W (psf)


405 360 321 288 260 235 213
648 576 514 461 415 375 340
36/4
2652
2351
2319
2319

176
281
-

161
257
-

147
235
-

135
215
135

122
198
122

Attachment Pattern
2620 2590 2596
2332 2314 2331
2301 2285 2303
2301 2284 2302

2569
2315
2288
2287

2545
2299
2273
2273

2522
2285
2260
2260

2500
2272
2248
2247

2480
2260
2236
2236

Mno/= 55.9 kip-in/ft


Mno= 85.5 kip-in/ft

Icr = 62.7 in4/ft


Iu = 112.8 in4/ft

Vn/ = 4.06 kip/ft


Vn = 6.09 kip/ft

D PANEL

LRFD - Diaphragm Shear, Sn (plf / ft)


2881 2823 2772 2770 2727 2688
2467 2434 2404 2422 2396 2373
2423 2392 2365 2385 2361 2339
2422 2391 2364 2384 2360 2338

193
309
-

C PANELS

8'-0"

Vn/ = 4.06 kip/ft


Vn = 6.09 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


2663 2619 2580 2573 2540 2510
2343 2318 2295 2303 2284 2266
2319 2296 2275 2284 2265 2249
2303 2280 2260 2270 2252 2236

Concrete + Deck = 46.5 psf


(Icr+Iu)/2 = 87.74 in4/ft

LRFD - Diaphragm Shear, Sn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width

3/4" Welded Shear Studs


12 in o.c.
24 in o.c.
36 in o.c.

www.ascsd.com

6x6 W1.4xW1.4

As = 0.028 in2/ft
3190
3190
3190

6x6 W2.9xW2.9

As = 0.058 in2/ft
4540
4540
4540

6x6 W4.0xW4.0

As = 0.080 in2/ft
5530
5530
5170

4x4 W4xW4

As = 0.120 in2/ft
7330
7330
5170

4x4 W6xW6

As = 0.180 in2/ft
10030
7750
5170

Composite and Non-Composite Deck Catalog May 2014

ACUSTADEK

All Gages

92
148
-

8'-6"

Vertical Load Span (in)

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

102
163
-

8'-0"

Concrete + Deck = 45.8 psf


(Icr+Iu)/2 = 80.51 in4/ft

16

112
179
-

N PANELS

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

123
197
-

B PANELS

ASD, W/
LRFD, W
L/360

36/4
2417
2212
2196
2185

136
218
-

Icr = 49.4 in4/ft


Iu = 105.2 in4/ft

Concrete + Deck = 45.5 psf


(Icr+Iu)/2 = 77.32 in4/ft
Vertical Load Span (in)

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

2W PANELS

19

8'-0"

3W PANELS

GA

3WH-36 Composite Deck 2.4

GENERAL INFORMATION

61

TABLE OF CONTENTS

2.4 3WH-36 Composite Deck

512" Total Slab Depth


Normal Weight Concrete (145 pcf)
Concrete Volume 1.235yd3/100ft2

Gage
22
21
20
GA

22

Single
9' - 3"
10' - 5"
10' - 11"

Maximum Unshored Span (in)


Triple
Gage
10' - 9"
19
11' - 9"
18
12' - 2"
16

Double
10' - 5"
11' - 4"
11' - 9"

Vertical Load Span (in)

8'-0"

8'-6"

ASD, W/
LRFD, W
L/360

311
498
-

271
434
-

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

9'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


2856 2831 2808 2799 2780 2763
2668 2653 2641 2640 2629 2619
2653 2639 2627 2627 2617 2608
2639 2627 2615 2616 2606 2597

ASD, W/
LRFD, W
L/360
21

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

76
121
-

68
109
-

61
98
-

Attachment Pattern
2734 2721 2717
2602 2595 2596
2592 2585 2587
2582 2576 2578

2706
2589
2580
2572

2695
2583
2574
2566

2685
2578
2569
2561

2676
2572
2564
2557

2668
2567
2559
2552

Mno/= 35.1 kip-in/ft


Mno= 53.6 kip-in/ft

354
566
-

8'-6"

ASD, W/
LRFD, W
L/360

375
599
-

328
524
-

36/4
2795
2637
2625
2614

122
196
-

110
176
-

99
159
-

90
143
-

81
130
-

73
117
-

Attachment Pattern
2779 2764 2760
2628 2619 2622
2616 2608 2611
2606 2598 2601

2747
2614
2603
2594

2735
2607
2597
2588

2724
2600
2590
2582

2713
2594
2584
2576

2704
2588
2579
2571

Mno/= 39.4 kip-in/ft


Mno= 60.2 kip-in/ft

Icr = 53.4 in4/ft


Iu = 133.1 in4/ft
9'-0"

Vn/ = 3.60 kip/ft


Vn = 5.22 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


2919 2890 2864 2854 2833 2813
2702 2686 2671 2671 2659 2647
2686 2670 2656 2657 2646 2635
2671 2656 2643 2645 2634 2624

Vn/ = 4.19 kip/ft


Vn = 6.03 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

ASD & LRFD - Superimposed Load, W (psf)


288 255 226 201 180 161 145
461 407 361 322 288 258 232
-

LRFD - Diaphragm Shear, Sn (plf / ft)


2952 2920 2892 2883 2860 2838
2720 2702 2687 2688 2674 2662
2702 2686 2671 2673 2660 2649
2687 2671 2657 2660 2648 2637

Concrete + Deck = 51.3 psf


(Icr+Iu)/2 = 95.1 in4/ft

62

84
135
-

ASD & LRFD - Superimposed Load, W (psf)


309 271 240 213 189 169 151 136
494 434 383 340 303 270 242 217
-

8'-0"

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

94
150
-

8'-6"

Vertical Load Span (in)

Triple
13' - 4"
13' - 11"
14' - 8"

105
168
-

8'-0"

Concrete + Deck = 51.2 psf


(Icr+Iu)/2 = 93.3 in4/ft

20

36/4
2748
2610
2600
2590

Icr = 48.4 in4/ft


Iu = 130.7 in4/ft
9'-0"

Double
12' - 11"
13' - 8"
15' - 3"

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

ASD & LRFD - Superimposed Load, W (psf)


238 209 185 164 146 131 117
380 335 296 263 234 209 187
-

Concrete + Deck = 51.0 psf


(Icr+Iu)/2 = 89.5 in4/ft
Vertical Load Span (in)

Single
11' - 7"
11' - 11"
12' - 6"

36/4
2819
2651
2638
2627

Icr = 55.8 in4/ft


Iu = 134.4 in4/ft

Composite and Non-Composite Deck Catalog May 2014

131
209
-

118
189
-

107
171
-

96
154
-

87
140
-

79
126
-

Attachment Pattern
2802 2786 2783
2641 2632 2635
2629 2620 2624
2618 2610 2614

2769
2626
2616
2606

2756
2619
2608
2599

2744
2612
2601
2593

2733
2605
2595
2587

2722
2599
2589
2581

Mno/= 41.5 kip-in/ft


Mno= 63.5 kip-in/ft

Vn/ = 4.55 kip/ft


Vn = 6.52 kip/ft

www.ascsd.com

TABLE OF CONTENTS

512" Total Slab Depth


Normal Weight Concrete (145 pcf)

Concrete Volume 1.235yd3/100ft2

Vertical Load Span (in)


ASD, W/
LRFD, W
L/360
Arc Spot Weld 1/2" Effective Dia
PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

8'-6"

446
714
-

ASD & LRFD - Superimposed Load, W (psf)


391 345 305 272 243 218 196 177
626 551 488 435 389 349 314 283
-

9'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


3067 3029 2994 2986 2957 2931
2785 2763 2743 2748 2731 2716
2764 2743 2725 2730 2714 2700
2748 2728 2710 2717 2701 2688

18

99
159
-

Attachment Pattern
2886 2866 2865
2689 2678 2684
2675 2664 2671
2664 2653 2660

2848
2674
2661
2651

2831
2664
2651
2642

2816
2655
2643
2634

2802
2646
2635
2626

2789
2639
2627
2619

Mno/= 48.7 kip-in/ft


Mno= 74.5 kip-in/ft

496
794
-

ASD & LRFD - Superimposed Load, W (psf)


435 384 340 303 272 244 220 199
696 614 545 485 435 390 352 318
-

9'-0"

8'-6"

ASD, W/
LRFD, W
L/360

611
978
-

537
859
-

36/4
2974
2741
2724
2712

180
288
-

164
262
-

149
238
-

136
217
-

124
198
-

113
181
-

Attachment Pattern
2949 2926 2927
2726 2713 2722
2710 2697 2707
2699 2686 2696

2907
2710
2695
2685

2888
2698
2685
2675

2871
2688
2675
2665

2855
2678
2665
2656

2840
2669
2657
2648

Mno/= 53.7 kip-in/ft


Mno= 82.2 kip-in/ft

Icr = 69.1 in4/ft


Iu = 141.4 in4/ft
9'-0"

Vn/ = 4.68 kip/ft


Vn = 7.02 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

ASD & LRFD - Superimposed Load, W (psf)


474 422 377 338 305 275 250
759 675 603 541 487 440 399
36/4
3143
2842
2810
2809

207
331
-

189
302
-

173
277
-

159
254
-

146
233
-

Attachment Pattern
3110 3080 3086
2822 2804 2821
2792 2775 2793
2791 2774 2793

3060
2805
2778
2777

3035
2790
2764
2763

3012
2776
2751
2750

2991
2762
2738
2738

2971
2750
2727
2726

Mno/= 65.3 kip-in/ft


Mno= 99.9 kip-in/ft

Icr = 80.9 in4/ft


Iu = 148.1 in4/ft

Vn/ = 4.68 kip/ft


Vn = 7.02 kip/ft

D PANEL

LRFD - Diaphragm Shear, Sn (plf / ft)


3371 3314 3262 3261 3217 3178
2957 2924 2895 2912 2886 2863
2913 2883 2856 2875 2851 2830
2912 2882 2855 2875 2850 2829

227
363
-

C PANELS

8'-0"

Vn/ = 4.68 kip/ft


Vn = 7.02 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


3153 3109 3070 3063 3030 3001
2833 2808 2786 2794 2774 2757
2810 2786 2765 2774 2756 2739
2793 2771 2750 2760 2742 2726

Concrete + Deck = 52.7 psf


(Icr+Iu)/2 = 114 in4/ft

LRFD - Diaphragm Shear, Sn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width

3/4" Welded Shear Studs


12 in o.c.
24 in o.c.
36 in o.c.

www.ascsd.com

6x6 W1.4xW1.4

As = 0.028 in2/ft
3680
3680
3680

6x6 W2.9xW2.9

As = 0.058 in2/ft
5030
5030
5030

6x6 W4.0xW4.0

As = 0.080 in2/ft
6020
6020
5170

4x4 W4xW4

As = 0.120 in2/ft
7820
7750
5170

4x4 W6xW6

As = 0.180 in2/ft
10520
7750
5170

Composite and Non-Composite Deck Catalog May 2014

ACUSTADEK

All Gages

109
174
-

8'-6"

Vertical Load Span (in)

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

120
191
-

8'-0"

Concrete + Deck = 52.0 psf


(Icr+Iu)/2 = 105 in4/ft

16

132
211
-

N PANELS

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

145
232
-

B PANELS

ASD, W/
LRFD, W
L/360

36/4
2908
2702
2687
2675

160
256
-

Icr = 63.8 in4/ft


Iu = 138.5 in4/ft

Concrete + Deck = 51.7 psf


(Icr+Iu)/2 = 101 in4/ft
Vertical Load Span (in)

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

2W PANELS

19

8'-0"

3W PANELS

GA

3WH-36 Composite Deck 2.4

GENERAL INFORMATION

63

TABLE OF CONTENTS

2.4 3WH-36 Composite Deck


6" Total Slab Depth
Normal Weight Concrete (145 pcf)

Gage
22
21
20
GA

22

Concrete Volume 1.389yd3/100ft2

Single
8' - 10"
9' - 11"
10' - 5"

Maximum Unshored Span (in)


Triple
Gage
10' - 4"
19
11' - 3"
18
11' - 8"
16

Double
10' - 0"
10' - 11"
11' - 4"

Vertical Load Span (in)

8'-0"

8'-6"

ASD, W/
LRFD, W
L/360

358
573
-

313
500
-

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

9'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


3347 3321 3299 3289 3270 3253
3158 3144 3131 3130 3119 3110
3143 3130 3118 3118 3108 3098
3130 3117 3106 3106 3097 3088

ASD, W/
LRFD, W
L/360
21

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

88
141
-

79
127
-

71
114
-

Attachment Pattern
3224 3211 3207
3093 3085 3086
3082 3075 3077
3073 3066 3068

3196
3080
3071
3062

3186
3074
3065
3057

3176
3068
3060
3052

3167
3063
3055
3047

3158
3058
3050
3043

Mno/= 40.3 kip-in/ft


Mno= 61.6 kip-in/ft

408
652
-

8'-6"

ASD, W/
LRFD, W
L/360

432
691
-

378
604
-

36/4
3285
3128
3115
3105

142
227
-

128
204
-

115
184
-

104
167
-

94
151
-

85
136
-

Attachment Pattern
3269 3254 3251
3118 3109 3112
3107 3098 3101
3096 3089 3092

3238
3104
3094
3085

3226
3097
3087
3078

3214
3090
3081
3072

3204
3084
3075
3067

3194
3078
3069
3062

Mno/= 45.3 kip-in/ft


Mno= 69.2 kip-in/ft

Icr = 67.3 in4/ft


Iu = 171.8 in4/ft
9'-0"

Vn/ = 3.98 kip/ft


Vn = 5.80 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


3410 3380 3354 3345 3323 3303
3193 3176 3161 3162 3149 3138
3176 3160 3147 3148 3136 3125
3161 3147 3133 3135 3124 3114

Vn/ = 4.58 kip/ft


Vn = 6.61 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

ASD & LRFD - Superimposed Load, W (psf)


332 294 261 233 208 187 168
532 470 417 372 333 299 269
-

LRFD - Diaphragm Shear, Sn (plf / ft)


3442 3411 3383 3373 3350 3329
3211 3193 3177 3178 3165 3153
3193 3176 3161 3163 3151 3139
3178 3162 3148 3151 3139 3128

Concrete + Deck = 57.5 psf


(Icr+Iu)/2 = 121.8 in4/ft

64

98
157
-

ASD & LRFD - Superimposed Load, W (psf)


356 313 277 245 219 195 175 157
570 501 443 393 350 313 280 252
-

8'-0"

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

109
175
-

8'-6"

Vertical Load Span (in)

Triple
12' - 10"
13' - 7"
14' - 4"

121
194
-

8'-0"

Concrete + Deck = 57.4 psf


(Icr+Iu)/2 = 119.6 in4/ft

20

36/4
3238
3101
3090
3080

Icr = 61.0 in4/ft


Iu = 168.7 in4/ft
9'-0"

Double
12' - 5"
13' - 2"
14' - 8"

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

ASD & LRFD - Superimposed Load, W (psf)


274 242 214 190 169 151 135
439 387 342 304 271 242 217
-

Concrete + Deck = 57.2 psf


(Icr+Iu)/2 = 114.8 in4/ft
Vertical Load Span (in)

Single
11' - 3"
11' - 7"
12' - 3"

36/4
3310
3141
3129
3118

Icr = 70.4 in4/ft


Iu = 173.3 in4/ft

Composite and Non-Composite Deck Catalog May 2014

151
242
-

137
219
-

124
198
-

112
179
-

101
162
-

92
147
-

Attachment Pattern
3292 3276 3273
3131 3122 3125
3119 3110 3114
3109 3100 3104

3259
3117
3106
3097

3246
3109
3099
3090

3234
3102
3092
3083

3223
3095
3086
3077

3213
3089
3080
3072

Mno/= 47.7 kip-in/ft


Mno= 73.0 kip-in/ft

Vn/ = 4.94 kip/ft


Vn = 7.09 kip/ft

www.ascsd.com

TABLE OF CONTENTS

3WH-36 Composite Deck 2.4


6" Total Slab Depth
Normal Weight Concrete (145 pcf)

Vertical Load Span (in)


ASD, W/
LRFD, W
L/360
Arc Spot Weld 1/2" Effective Dia
PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

8'-6"

515
824
-

ASD & LRFD - Superimposed Load, W (psf)


451 398 353 314 281 252 227 205
722 636 564 502 449 403 363 328
-

9'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


3558 3519 3485 3476 3448 3422
3275 3253 3234 3238 3222 3206
3254 3233 3215 3221 3205 3190
3238 3218 3201 3207 3192 3178

18

115
185
-

Attachment Pattern
3376 3357 3355
3180 3168 3175
3165 3154 3161
3154 3143 3151

3338
3164
3151
3141

3322
3154
3142
3132

3307
3145
3133
3124

3293
3137
3125
3116

3280
3129
3118
3109

Mno/= 56.1 kip-in/ft


Mno= 85.8 kip-in/ft

572
916
-

ASD & LRFD - Superimposed Load, W (psf)


502 443 393 351 314 282 254 230
803 709 629 561 502 452 407 368
-

9'-0"

8'-6"

ASD, W/
LRFD, W
L/360

706
1129
-

620
992
-

36/4
3464
3231
3214
3202

209
334
-

190
303
-

173
276
-

158
252
-

144
230
-

132
211
-

Attachment Pattern
3439 3417 3417
3217 3203 3212
3200 3188 3197
3189 3177 3187

3397
3200
3186
3176

3379
3189
3175
3165

3361
3178
3165
3156

3345
3169
3156
3147

3330
3160
3147
3138

Mno/= 61.8 kip-in/ft


Mno= 94.6 kip-in/ft

Icr = 87.3 in4/ft


Iu = 182.0 in4/ft
9'-0"

Vn/ = 5.45 kip/ft


Vn = 8.18 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

ASD & LRFD - Superimposed Load, W (psf)


548 488 436 391 352 319 289
877 780 697 626 564 510 463
36/4
3633
3332
3300
3299

240
384
-

219
351
-

201
321
-

184
295
-

169
271
-

Attachment Pattern
3600 3571 3577
3313 3295 3312
3282 3266 3284
3281 3265 3283

3550
3295
3268
3268

3525
3280
3254
3254

3502
3266
3241
3240

3481
3253
3229
3228

3461
3241
3217
3217

Mno/= 75.3 kip-in/ft


Mno= 115.2 kip-in/ft

Icr = 102.3 in4/ft


Iu = 190.3 in4/ft

Vn/ = 5.45 kip/ft


Vn = 8.18 kip/ft

D PANEL

LRFD - Diaphragm Shear, Sn (plf / ft)


3861 3804 3753 3751 3708 3669
3448 3415 3385 3403 3377 3353
3404 3373 3346 3366 3342 3320
3403 3372 3345 3365 3341 3319

263
421
-

C PANELS

8'-0"

Vn/ = 5.45 kip/ft


Vn = 8.18 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


3644 3600 3561 3554 3521 3491
3324 3299 3276 3284 3265 3247
3300 3277 3255 3264 3246 3229
3284 3261 3241 3251 3233 3217

Concrete + Deck = 58.8 psf


(Icr+Iu)/2 = 146.3 in4/ft

LRFD - Diaphragm Shear, Sn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width

3/4" Welded Shear Studs


12 in o.c.
24 in o.c.
36 in o.c.

www.ascsd.com

6x6 W1.4xW1.4

As = 0.028 in2/ft
4170
4170
4170

6x6 W2.9xW2.9

As = 0.058 in2/ft
5520
5520
5170

6x6 W4.0xW4.0

As = 0.080 in2/ft
6510
6510
5170

4x4 W4xW4

As = 0.120 in2/ft
8310
7750
5170

4x4 W6xW6

As = 0.180 in2/ft
11010
7750
5170

Composite and Non-Composite Deck Catalog May 2014

ACUSTADEK

All Gages

127
202
-

8'-6"

Vertical Load Span (in)

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

139
222
-

8'-0"

Concrete + Deck = 58.1 psf


(Icr+Iu)/2 = 134.7 in4/ft

16

153
244
-

N PANELS

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

168
269
-

B PANELS

ASD, W/
LRFD, W
L/360

36/4
3398
3193
3177
3165

185
296
-

Icr = 80.5 in4/ft


Iu = 178.4 in4/ft

Concrete + Deck = 57.9 psf


(Icr+Iu)/2 = 129.5 in4/ft
Vertical Load Span (in)

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

2W PANELS

19

8'-0"

3W PANELS

GA

Concrete Volume 1.389yd3/100ft2

GENERAL INFORMATION

65

TABLE OF CONTENTS

2.4 3WH-36 Composite Deck

6 12" Total Slab Depth


Normal Weight Concrete (145 pcf)

Gage
22
21
20
GA

22

Concrete Volume 1.543yd3/100ft2


1 Hour Fire Rating

Single
8' - 6"
9' - 7"
10' - 0"

Maximum Unshored Span (in)


Triple
Gage
9' - 11"
19
10' - 10"
18
11' - 3"
16

Double
9' - 7"
10' - 6"
10' - 11"

Vertical Load Span (in)

8'-0"

8'-6"

ASD, W/
LRFD, W
L/360

408
652
-

356
569
-

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

9'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


3837 3812 3789 3780 3761 3744
3648 3634 3621 3621 3610 3600
3634 3620 3608 3608 3598 3589
3620 3607 3596 3597 3587 3578

ASD, W/
LRFD, W
L/360
21

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

101
162
-

91
146
-

82
131
-

Attachment Pattern
3714 3702 3698
3583 3576 3577
3573 3566 3567
3563 3557 3559

3686
3570
3561
3553

3676
3564
3555
3547

3666
3558
3550
3542

3657
3553
3545
3537

3649
3548
3540
3533

Mno/= 45.7 kip-in/ft


Mno= 69.9 kip-in/ft

464
742
-

8'-6"

ASD, W/
LRFD, W
L/360

491
786
-

430
688
-

36/4
3776
3618
3606
3595

162
259
-

146
234
-

132
211
-

119
191
-

108
173
-

98
157
-

Attachment Pattern
3760 3745 3741
3609 3600 3602
3597 3589 3592
3587 3579 3582

3728
3595
3584
3575

3716
3587
3578
3569

3705
3581
3571
3563

3694
3575
3565
3557

3685
3569
3560
3552

Mno/= 51.3 kip-in/ft


Mno= 78.6 kip-in/ft

Icr = 83.3 in4/ft


Iu = 217.6 in4/ft
9'-0"

Vn/ = 4.42 kip/ft


Vn = 6.46 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


3900 3871 3845 3835 3813 3794
3683 3667 3652 3652 3640 3628
3666 3651 3637 3638 3626 3616
3652 3637 3624 3626 3615 3604

Vn/ = 5.02 kip/ft


Vn = 7.27 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

ASD & LRFD - Superimposed Load, W (psf)


378 335 297 265 237 213 192
605 535 476 424 380 341 307
-

LRFD - Diaphragm Shear, Sn (plf / ft)


3932 3901 3873 3864 3840 3819
3701 3683 3667 3669 3655 3643
3683 3667 3652 3654 3641 3630
3668 3652 3638 3641 3629 3618

Concrete + Deck = 63.7 psf


(Icr+Iu)/2 = 153.2 in4/ft

66

112
180
-

ASD & LRFD - Superimposed Load, W (psf)


405 356 315 280 249 223 200 180
649 570 504 447 399 357 320 287
-

8'-0"

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

125
200
-

8'-6"

Vertical Load Span (in)

Triple
12' - 5"
13' - 1"
14' - 0"

139
222
-

8'-0"

Concrete + Deck = 63.5 psf


(Icr+Iu)/2 = 150.4 in4/ft

20

36/4
3728
3591
3580
3570

Icr = 75.4 in4/ft


Iu = 213.8 in4/ft
9'-0"

Double
12' - 0"
12' - 8"
14' - 2"

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

ASD & LRFD - Superimposed Load, W (psf)


312 275 244 217 193 173 155
499 440 390 347 309 276 248
-

Concrete + Deck = 63.3 psf


(Icr+Iu)/2 = 144.6 in4/ft
Vertical Load Span (in)

Single
10' - 11"
11' - 4"
11' - 11"

36/4
3800
3632
3619
3608

Icr = 87.1 in4/ft


Iu = 219.4 in4/ft

Composite and Non-Composite Deck Catalog May 2014

173
277
-

156
250
-

142
227
-

128
205
-

116
186
-

106
169
-

Attachment Pattern
3783 3767 3764
3622 3612 3616
3609 3601 3604
3599 3591 3595

3750
3607
3596
3587

3737
3600
3589
3580

3725
3592
3582
3574

3713
3586
3576
3568

3703
3580
3570
3562

Mno/= 54.1 kip-in/ft


Mno= 82.8 kip-in/ft

Vn/ = 5.38 kip/ft


Vn = 7.75 kip/ft

www.ascsd.com

TABLE OF CONTENTS

3WH-36 Composite Deck 2.4


6 12" Total Slab Depth
Normal Weight Concrete (145 pcf)

Concrete Volume 1.543yd3/100ft2


2 Hour Fire Rating

Vertical Load Span (in)


ASD, W/
LRFD, W
L/360
Arc Spot Weld 1/2" Effective Dia
PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

8'-6"

586
938
-

ASD & LRFD - Superimposed Load, W (psf)


514 453 402 358 320 287 259 234
822 725 643 573 512 460 414 374
-

9'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


4048 4010 3975 3967 3938 3912
3766 3744 3724 3729 3712 3697
3745 3724 3705 3711 3695 3681
3728 3709 3691 3698 3682 3668

18

16

Attachment Pattern
3867 3847 3846
3670 3659 3665
3656 3645 3651
3644 3634 3641

3828
3654
3641
3632

3812
3645
3632
3623

3797
3636
3624
3614

3783
3627
3616
3607

3770
3619
3608
3600

Mno/= 63.7 kip-in/ft


Mno= 97.4 kip-in/ft

8'-6"

652
1043
-

ASD & LRFD - Superimposed Load, W (psf)


572 505 448 400 358 322 291 263
915 808 717 640 573 515 465 421
-

9'-0"

8'-0"

8'-6"

36/4
3955
3722
3705
3693

239
382
-

217
347
-

198
316
-

180
289
-

165
264
-

151
241
-

Attachment Pattern
3930 3907 3908
3707 3694 3703
3691 3678 3688
3679 3667 3677

3888
3691
3676
3666

3869
3679
3665
3656

3852
3669
3656
3646

3836
3659
3646
3637

3821
3650
3638
3629

Mno/= 70.3 kip-in/ft


Mno= 107.5 kip-in/ft

Icr = 108.2 in4/ft


Iu = 230.1 in4/ft
9'-0"

Vn/ = 6.33 kip/ft


Vn = 9.50 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


4134 4090 4051 4044 4011 3982
3814 3789 3767 3775 3755 3738
3791 3767 3746 3755 3736 3720
3774 3751 3731 3741 3723 3707

Vn/ = 6.33 kip/ft


Vn = 9.50 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

ASD & LRFD - Superimposed Load, W (psf)


805 707 625 556 497 447 403 364 331
1287 1131 1001 890 796 715 644 583 529
LRFD - Diaphragm Shear, Sn (plf / ft)
4352 4294 4243 4242 4198 4159
3938 3905 3876 3893 3867 3844
3894 3864 3837 3856 3832 3810
3893 3863 3836 3855 3831 3810

Concrete + Deck = 65.0 psf


(Icr+Iu)/2 = 183.6 in4/ft

36/4
4123
3823
3791
3790

301
481
-

274
439
-

251
401
-

230
368
-

211
338
-

194
310
-

Attachment Pattern
4091 4061 4067
3803 3785 3802
3773 3756 3774
3772 3755 3774

4040
3786
3759
3758

4016
3771
3745
3744

3993
3756
3731
3731

3972
3743
3719
3719

3952
3731
3708
3707

Mno/= 85.7 kip-in/ft


Mno= 131.1 kip-in/ft

Icr = 127.0 in4/ft


Iu = 240.2 in4/ft

Vn/ = 6.33 kip/ft


Vn = 9.50 kip/ft

LRFD - Diaphragm Shear, Sn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width

3/4" Welded Shear Studs


12 in o.c.
24 in o.c.
36 in o.c.

www.ascsd.com

6x6 W1.4xW1.4

As = 0.028 in2/ft
n/a
n/a
n/a

6x6 W2.9xW2.9

As = 0.058 in2/ft
6010
6010
5170

6x6 W4.0xW4.0

As = 0.080 in2/ft
7000
7000
5170

4x4 W4xW4

As = 0.120 in2/ft
8800
7750
5170

4x4 W6xW6

As = 0.180 in2/ft
11500
7750
5170

Composite and Non-Composite Deck Catalog May 2014

ACUSTADEK

All Gages

132
212
-

D PANEL

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

145
232
-

C PANELS

ASD, W/
LRFD, W
L/360

159
255
-

8'-0"

Concrete + Deck = 64.3 psf


(Icr+Iu)/2 = 169.1 in4/ft
Vertical Load Span (in)

175
280
-

N PANELS

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

192
307
-

B PANELS

ASD, W/
LRFD, W
L/360

36/4
3888
3683
3668
3656

212
339
-

Icr = 99.7 in4/ft


Iu = 225.7 in4/ft

Concrete + Deck = 64.0 psf


(Icr+Iu)/2 = 162.7 in4/ft
Vertical Load Span (in)

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

2W PANELS

19

8'-0"

3W PANELS

GA

GENERAL INFORMATION

67

TABLE OF CONTENTS

2.4 3WH-36 Composite Deck

7 12" Total Slab Depth


Normal Weight Concrete (145 pcf)

Gage
22
21
20
GA

22

Concrete Volume 1.852yd3/100ft2


2 Hour Fire Rating

Single
7' - 11"
8' - 11"
9' - 4"

Maximum Unshored Span (in)


Triple
Gage
9' - 4"
19
10' - 2"
18
10' - 6"
16

Double
9' - 0"
9' - 10"
10' - 2"

Vertical Load Span (in)

8'-0"

8'-6"

ASD, W/
LRFD, W
L/360

510
816
-

445
712
-

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

9'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


4818 4793 4770 4761 4742 4725
4629 4615 4602 4601 4591 4581
4615 4601 4589 4589 4579 4570
4601 4588 4577 4578 4568 4559

ASD, W/
LRFD, W
L/360
21

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

128
205
-

116
185
-

104
167
-

Attachment Pattern
4695 4682 4679
4564 4556 4558
4554 4547 4548
4544 4537 4539

4667
4551
4542
4534

4657
4545
4536
4528

4647
4539
4531
4523

4638
4534
4526
4518

4630
4529
4521
4514

Mno/= 56.9 kip-in/ft


Mno= 87.0 kip-in/ft

581
929
-

8'-6"

ASD, W/
LRFD, W
L/360

615
985
-

539
862
-

36/4
4757
4599
4587
4576

204
327
-

185
295
-

167
267
-

151
242
-

137
219
-

124
199
-

Attachment Pattern
4740 4726 4722
4589 4581 4583
4578 4570 4573
4568 4560 4563

4709
4575
4565
4556

4697
4568
4558
4550

4686
4562
4552
4544

4675
4555
4546
4538

4665
4550
4541
4533

Mno/= 64.0 kip-in/ft


Mno= 97.9 kip-in/ft

Icr = 121.2 in4/ft


Iu = 333.8 in4/ft
9'-0"

Vn/ = 5.30 kip/ft


Vn = 7.78 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


4881 4852 4826 4816 4794 4775
4664 4647 4633 4633 4621 4609
4647 4632 4618 4619 4607 4597
4633 4618 4605 4607 4595 4585

Vn/ = 5.90 kip/ft


Vn = 8.59 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

ASD & LRFD - Superimposed Load, W (psf)


474 420 373 333 299 268 242
759 672 597 533 478 429 387
-

LRFD - Diaphragm Shear, Sn (plf / ft)


4913 4882 4854 4844 4821 4800
4682 4664 4648 4650 4636 4624
4664 4647 4633 4635 4622 4610
4649 4633 4619 4622 4610 4599

Concrete + Deck = 76.0 psf


(Icr+Iu)/2 = 231.6 in4/ft

68

142
228
-

ASD & LRFD - Superimposed Load, W (psf)


508 447 395 351 313 280 252 226
812 715 632 562 501 448 403 362
-

8'-0"

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

158
253
-

8'-6"

Vertical Load Span (in)

Triple
11' - 7"
12' - 3"
13' - 5"

175
281
-

8'-0"

Concrete + Deck = 75.9 psf


(Icr+Iu)/2 = 227.5 in4/ft

20

36/4
4709
4572
4561
4551

Icr = 109.6 in4/ft


Iu = 328.5 in4/ft
9'-0"

Double
11' - 3"
11' - 10"
13' - 3"

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

ASD & LRFD - Superimposed Load, W (psf)


391 345 306 272 243 217 195
625 552 489 435 389 348 312
-

Concrete + Deck = 75.6 psf


(Icr+Iu)/2 = 219 in4/ft
Vertical Load Span (in)

Single
10' - 4"
10' - 8"
11' - 5"

36/4
4781
4613
4600
4589

Icr = 126.8 in4/ft


Iu = 336.4 in4/ft

Composite and Non-Composite Deck Catalog May 2014

218
349
-

198
316
-

179
287
-

163
260
-

148
236
-

134
215
-

Attachment Pattern
4764 4748 4745
4603 4593 4597
4590 4582 4585
4580 4571 4576

4731
4588
4577
4568

4718
4580
4570
4561

4706
4573
4563
4555

4694
4567
4557
4549

4684
4560
4551
4543

Mno/= 67.5 kip-in/ft


Mno= 103.3 kip-in/ft

Vn/ = 6.26 kip/ft


Vn = 9.07 kip/ft

www.ascsd.com

TABLE OF CONTENTS

7 12" Total Slab Depth


Normal Weight Concrete (145 pcf)

Concrete Volume 1.852yd3/100ft2


2 Hour Fire Rating

Vertical Load Span (in)


ASD, W/
LRFD, W
L/360
Arc Spot Weld 1/2" Effective Dia
PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

8'-6"

9'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


5029 4991 4956 4948 4919 4893
4747 4725 4705 4710 4693 4678
4725 4705 4686 4692 4676 4662
4709 4690 4672 4678 4663 4649

18

16

9'-0"

Attachment Pattern
4848 4828 4827
4651 4640 4646
4637 4626 4632
4625 4615 4622

4809
4635
4622
4612

4793
4626
4613
4604

4778
4617
4605
4595

4764
4608
4597
4588

4751
4600
4589
4580

Mno/= 79.5 kip-in/ft


Mno= 121.7 kip-in/ft

8'-0"

8'-6"

36/4
4935
4703
4686
4674

301
482
-

274
439
-

250
400
-

228
366
-

209
335
-

192
307
-

Attachment Pattern
4911 4888 4889
4688 4675 4684
4672 4659 4669
4660 4648 4658

4868
4671
4657
4647

4850
4660
4646
4637

4833
4650
4636
4627

4817
4640
4627
4618

4802
4631
4618
4610

Mno/= 87.9 kip-in/ft


Mno= 134.5 kip-in/ft

Icr = 158.2 in4/ft


Iu = 351.6 in4/ft
9'-0"

Vn/ = 7.76 kip/ft


Vn = 11.12 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


5115 5071 5032 5025 4992 4962
4795 4770 4747 4755 4736 4718
4772 4748 4727 4736 4717 4701
4755 4732 4712 4722 4704 4688

Vn/ = 8.09 kip/ft


Vn = 12.14 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

ASD & LRFD - Superimposed Load, W (psf)


1012 890 787 701 627 563 508 460 418
1619 1424 1260 1121 1003 901 813 736 668
LRFD - Diaphragm Shear, Sn (plf / ft)
5333 5275 5224 5222 5179 5140
4919 4886 4856 4874 4848 4825
4875 4845 4817 4837 4813 4791
4874 4844 4816 4836 4812 4790

Concrete + Deck = 77.3 psf


(Icr+Iu)/2 = 276.1 in4/ft

36/4
5104
4803
4772
4771

380
608
-

347
556
-

318
508
-

291
466
-

268
428
-

246
394
-

Attachment Pattern
5072 5042 5048
4784 4766 4783
4753 4737 4755
4753 4736 4754

5021
4767
4740
4739

4997
4751
4726
4725

4974
4737
4712
4712

4952
4724
4700
4699

4933
4712
4689
4688

Mno/= 107.4 kip-in/ft


Mno= 164.3 kip-in/ft

Icr = 186.3 in4/ft


Iu = 366.0 in4/ft

Vn/ = 8.09 kip/ft


Vn = 12.14 kip/ft

LRFD - Diaphragm Shear, Sn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width

3/4" Welded Shear Studs


12 in o.c.
24 in o.c.
36 in o.c.

www.ascsd.com

6x6 W1.4xW1.4

As = 0.028 in2/ft
n/a
n/a
n/a

6x6 W2.9xW2.9

As = 0.058 in2/ft
7000
7000
5170

6x6 W4.0xW4.0

As = 0.080 in2/ft
7990
7750
5170

4x4 W4xW4

As = 0.120 in2/ft
9790
7750
5170

4x4 W6xW6

As = 0.180 in2/ft
12490
7750
5170

Composite and Non-Composite Deck Catalog May 2014

ACUSTADEK

All Gages

168
269
-

D PANEL

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

184
294
-

C PANELS

ASD, W/
LRFD, W
L/360

201
322
-

ASD & LRFD - Superimposed Load, W (psf)


818 718 634 564 503 451 406 366 332
1309 1149 1015 902 805 721 649 586 531
-

Concrete + Deck = 76.6 psf


(Icr+Iu)/2 = 254.9 in4/ft
Vertical Load Span (in)

221
354
-

N PANELS

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

8'-6"

243
388
-

B PANELS

ASD, W/
LRFD, W
L/360

8'-0"

36/4
4869
4664
4649
4637

267
428
-

Icr = 145.6 in4/ft


Iu = 345.3 in4/ft

Concrete + Deck = 76.4 psf


(Icr+Iu)/2 = 245.5 in4/ft
Vertical Load Span (in)

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

ASD & LRFD - Superimposed Load, W (psf)


735 645 569 505 450 403 362 326 295
1176 1031 910 807 720 644 579 522 472
-

2W PANELS

19

8'-0"

3W PANELS

GA

3WH-36 Composite Deck 2.4

GENERAL INFORMATION

69

TABLE OF CONTENTS

2.4 3WH-36 Composite Deck

8 14" Total Slab Depth


Normal Weight Concrete (145 pcf)

Gage
22
21
20
GA

22

Concrete Volume 2.083yd3/100ft2


3 Hour Fire Rating

Single
7' - 7"
8' - 6"
8' - 11"

Maximum Unshored Span (in)


Triple
Gage
8' - 11"
19
9' - 8"
18
10' - 1"
16

Double
8' - 7"
9' - 5"
9' - 9"

Vertical Load Span (in)

8'-0"

8'-6"

ASD, W/
LRFD, W
L/360

589
943
-

515
823
-

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

9'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


5554 5528 5506 5496 5477 5460
5365 5351 5338 5337 5326 5317
5350 5337 5325 5325 5315 5305
5337 5324 5313 5313 5304 5295

ASD, W/
LRFD, W
L/360
21

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

149
239
-

135
216
-

122
195
-

Attachment Pattern
5431 5418 5414
5300 5292 5293
5289 5282 5284
5280 5273 5275

5403
5287
5278
5269

5392
5281
5272
5264

5383
5275
5266
5259

5374
5270
5261
5254

5365
5265
5257
5249

Mno/= 65.5 kip-in/ft


Mno= 100.3 kip-in/ft

671
1074
-

8'-6"

ASD, W/
LRFD, W
L/360

712
1138
-

623
997
-

36/4
5492
5335
5322
5312

237
380
-

214
343
-

194
311
-

176
282
-

160
256
-

145
232
-

Attachment Pattern
5476 5461 5458
5325 5316 5319
5313 5305 5308
5303 5295 5299

5445
5311
5301
5292

5433
5304
5294
5285

5421
5297
5288
5279

5411
5291
5282
5274

5401
5285
5276
5269

Mno/= 73.8 kip-in/ft


Mno= 112.9 kip-in/ft

Icr = 155.1 in4/ft


Iu = 445.5 in4/ft
9'-0"

Vn/ = 5.96 kip/ft


Vn = 8.77 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


5617 5587 5561 5552 5530 5510
5400 5383 5368 5369 5356 5345
5383 5367 5353 5355 5343 5332
5368 5354 5340 5342 5331 5321

Vn/ = 6.56 kip/ft


Vn = 9.58 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

ASD & LRFD - Superimposed Load, W (psf)


549 486 432 386 346 311 281
878 778 692 618 554 498 449
-

LRFD - Diaphragm Shear, Sn (plf / ft)


5649 5618 5590 5580 5557 5536
5417 5400 5384 5385 5372 5360
5400 5383 5368 5370 5358 5346
5385 5369 5355 5358 5346 5335

Concrete + Deck = 85.2 psf


(Icr+Iu)/2 = 305.6 in4/ft

70

166
265
-

ASD & LRFD - Superimposed Load, W (psf)


587 517 457 407 363 325 292 263
939 827 732 650 580 520 467 420
-

8'-0"

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

184
294
-

8'-6"

Vertical Load Span (in)

Triple
11' - 1"
11' - 9"
13' - 1"

204
326
-

8'-0"

Concrete + Deck = 85.1 psf


(Icr+Iu)/2 = 300.3 in4/ft

20

36/4
5445
5308
5297
5287

Icr = 140.0 in4/ft


Iu = 438.9 in4/ft
9'-0"

Double
10' - 9"
11' - 4"
12' - 8"

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

ASD & LRFD - Superimposed Load, W (psf)


452 399 354 315 282 252 226
723 639 567 504 451 404 362
-

Concrete + Deck = 84.9 psf


(Icr+Iu)/2 = 289.4 in4/ft
Vertical Load Span (in)

Single
9' - 11"
10' - 4"
11' - 1"

36/4
5517
5348
5336
5325

Icr = 162.3 in4/ft


Iu = 448.8 in4/ft

Composite and Non-Composite Deck Catalog May 2014

254
406
-

230
368
-

208
333
-

189
303
-

172
275
-

157
251
-

Attachment Pattern
5499 5483 5480
5338 5329 5332
5326 5317 5321
5315 5307 5311

5466
5324
5313
5304

5453
5316
5306
5297

5441
5309
5299
5290

5430
5302
5293
5284

5419
5296
5287
5279

Mno/= 77.9 kip-in/ft


Mno= 119.1 kip-in/ft

Vn/ = 6.91 kip/ft


Vn = 10.06 kip/ft

www.ascsd.com

TABLE OF CONTENTS

8 14" Total Slab Depth


Normal Weight Concrete (145 pcf)

Concrete Volume 2.083yd3/100ft2


3 Hour Fire Rating

Vertical Load Span (in)


ASD, W/
LRFD, W
L/360
Arc Spot Weld 1/2" Effective Dia
PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

8'-6"

9'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


5765 5726 5692 5683 5655 5629
5482 5460 5441 5445 5429 5413
5461 5440 5422 5428 5412 5397
5445 5425 5408 5414 5399 5385

18

16

9'-0"

Attachment Pattern
5583 5564 5562
5387 5375 5381
5372 5361 5368
5361 5350 5358

5545
5371
5358
5348

5529
5361
5349
5339

5514
5352
5340
5331

5500
5344
5332
5323

5487
5336
5325
5316

Mno/= 91.8 kip-in/ft


Mno= 140.5 kip-in/ft

8'-0"

8'-6"

36/4
5671
5438
5421
5409

350
560
-

319
510
-

291
466
-

266
426
-

244
390
-

223
358
-

Attachment Pattern
5646 5624 5624
5424 5410 5419
5407 5395 5404
5396 5384 5394

5604
5407
5393
5383

5586
5396
5382
5372

5568
5385
5372
5363

5552
5376
5363
5354

5537
5367
5354
5345

Mno/= 101.6 kip-in/ft


Mno= 155.5 kip-in/ft

Icr = 203.1 in4/ft


Iu = 467.9 in4/ft
9'-0"

Vn/ = 8.42 kip/ft


Vn = 12.11 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


5851 5807 5768 5761 5728 5698
5531 5505 5483 5491 5472 5454
5507 5483 5462 5471 5453 5436
5491 5468 5448 5457 5440 5424

Vn/ = 9.36 kip/ft


Vn = 13.38 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

ASD & LRFD - Superimposed Load, W (psf)


1174 1032 914 813 728 654 590 534 486
1878 1652 1462 1302 1164 1047 944 855 777
LRFD - Diaphragm Shear, Sn (plf / ft)
6068 6011 5960 5958 5915 5876
5655 5621 5592 5610 5584 5560
5611 5580 5553 5573 5549 5527
5610 5579 5552 5572 5548 5526

Concrete + Deck = 86.5 psf


(Icr+Iu)/2 = 362.9 in4/ft

36/4
5840
5539
5507
5506

442
708
-

404
647
-

370
592
-

340
543
-

312
499
-

287
460
-

Attachment Pattern
5807 5778 5784
5520 5502 5519
5489 5473 5491
5488 5472 5490

5757
5502
5475
5475

5732
5487
5461
5461

5709
5473
5448
5447

5688
5460
5436
5435

5668
5448
5424
5424

Mno/= 124.3 kip-in/ft


Mno= 190.3 kip-in/ft

Icr = 239.7 in4/ft


Iu = 486.2 in4/ft

Vn/ = 9.41 kip/ft


Vn = 14.12 kip/ft

LRFD - Diaphragm Shear, Sn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width

3/4" Welded Shear Studs


12 in o.c.
24 in o.c.
36 in o.c.

www.ascsd.com

6x6 W1.4xW1.4

As = 0.028 in2/ft
n/a
n/a
n/a

6x6 W2.9xW2.9

As = 0.058 in2/ft
7740
7740
5170

6x6 W4.0xW4.0

As = 0.080 in2/ft
8730
7750
5170

4x4 W4xW4

As = 0.120 in2/ft
10530
7750
5170

4x4 W6xW6

As = 0.180 in2/ft
13230
7750
5170

Composite and Non-Composite Deck Catalog May 2014

ACUSTADEK

All Gages

196
314
-

D PANEL

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

214
343
-

C PANELS

ASD, W/
LRFD, W
L/360

235
375
-

ASD & LRFD - Superimposed Load, W (psf)


948 832 735 653 583 523 471 425 385
1516 1331 1176 1045 933 837 753 681 617
-

Concrete + Deck = 85.9 psf


(Icr+Iu)/2 = 335.5 in4/ft
Vertical Load Span (in)

257
411
-

N PANELS

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

8'-6"

282
452
-

B PANELS

ASD, W/
LRFD, W
L/360

8'-0"

36/4
5605
5399
5384
5372

311
497
-

Icr = 186.7 in4/ft


Iu = 460.1 in4/ft

Concrete + Deck = 85.6 psf


(Icr+Iu)/2 = 323.4 in4/ft
Vertical Load Span (in)

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

ASD & LRFD - Superimposed Load, W (psf)


851 746 659 585 521 467 420 379 342
1361 1194 1054 935 834 747 672 606 548
-

2W PANELS

19

8'-0"

3W PANELS

GA

3WH-36 Composite Deck 2.4

GENERAL INFORMATION

71

TABLE OF CONTENTS

2.4 3WH-36 Composite Deck


5" Total Slab Depth
Light Weight Concrete (110 pcf)

Gage
22
21
20
GA

22

Concrete Volume 1.080yd3/100ft2

Single
10' - 8"
12' - 1"
12' - 3"

Maximum Unshored Span (in)


Triple
Gage
12' - 4"
19
13' - 5"
18
13' - 11"
16

Double
11' - 10"
13' - 0"
13' - 6"

Vertical Load Span (in)

8'-0"

8'-6"

ASD, W/
LRFD, W
L/360

261
418
-

229
366
-

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

9'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


1710 1685 1662 1652 1634 1617
1521 1507 1494 1493 1483 1473
1507 1493 1481 1481 1471 1462
1493 1480 1469 1469 1460 1451

ASD, W/
LRFD, W
L/360
21

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

68
109
-

62
99
-

56
89
-

Attachment Pattern
1587 1574 1571
1456 1448 1450
1446 1439 1440
1436 1429 1431

1559
1443
1434
1426

1549
1437
1428
1420

1539
1431
1423
1415

1530
1426
1418
1410

1522
1421
1413
1406

Mno/= 28.8 kip-in/ft


Mno= 44.1 kip-in/ft

296
473
-

8'-6"

ASD, W/
LRFD, W
L/360

312
500
-

274
438
-

36/4
1650
1492
1480
1469

106
169
-

96
153
-

87
139
-

79
126
-

72
115
-

66
105
-

Attachment Pattern
1634 1619 1616
1483 1474 1477
1471 1463 1466
1461 1453 1456

1602
1469
1459
1449

1590
1462
1452
1443

1579
1455
1445
1437

1569
1449
1440
1431

1559
1443
1434
1426

Mno/= 32.3 kip-in/ft


Mno= 49.4 kip-in/ft

Icr = 56.3 in4/ft


Iu = 109.1 in4/ft
9'-0"

Vn/ = 2.78 kip/ft


Vn = 4.00 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


1774 1745 1719 1709 1688 1668
1557 1541 1526 1526 1514 1503
1541 1525 1511 1512 1501 1490
1526 1511 1498 1500 1489 1479

Vn/ = 3.05 kip/ft


Vn = 4.80 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

ASD & LRFD - Superimposed Load, W (psf)


241 214 191 170 153 138 124
386 342 305 273 245 220 199
-

LRFD - Diaphragm Shear, Sn (plf / ft)


1807 1776 1748 1738 1715 1694
1576 1558 1542 1544 1530 1518
1558 1541 1527 1529 1516 1504
1543 1527 1513 1516 1504 1493

Concrete + Deck = 34.8 psf


(Icr+Iu)/2 = 84.53 in4/ft

72

75
120
-

ASD & LRFD - Superimposed Load, W (psf)


259 228 202 180 161 144 130 117
414 365 323 288 257 231 208 187
-

8'-0"

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

83
133
-

8'-6"

Vertical Load Span (in)

Triple
14' - 11"
15' - 4"
16' - 2"

92
147
-

8'-0"

Concrete + Deck = 34.6 psf


(Icr+Iu)/2 = 82.67 in4/ft

20

36/4
1601
1464
1453
1443

Icr = 51.3 in4/ft


Iu = 106.2 in4/ft
9'-0"

Double
14' - 10"
15' - 7"
17' - 2"

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

ASD & LRFD - Superimposed Load, W (psf)


201 178 158 141 126 113 102
322 285 253 225 202 181 163
-

Concrete + Deck = 34.4 psf


(Icr+Iu)/2 = 78.76 in4/ft
Vertical Load Span (in)

Single
12' - 9"
13' - 1"
13' - 9"

36/4
1675
1507
1494
1483

Icr = 58.6 in4/ft


Iu = 110.4 in4/ft

Composite and Non-Composite Deck Catalog May 2014

113
180
-

102
163
-

93
148
-

84
135
-

77
123
-

70
112
-

Attachment Pattern
1658 1642 1639
1497 1487 1491
1484 1476 1479
1474 1465 1470

1625
1482
1471
1462

1612
1474
1464
1455

1600
1467
1457
1449

1588
1461
1451
1442

1578
1454
1445
1437

Mno/= 34.0 kip-in/ft


Mno= 52.0 kip-in/ft

Vn/ = 3.05 kip/ft


Vn = 5.29 kip/ft

www.ascsd.com

TABLE OF CONTENTS

3WH-36 Composite Deck 2.4


5" Total Slab Depth
Light Weight Concrete (110 pcf)

Concrete Volume 1.080yd3/100ft2


Vertical Load Span (in)


ASD, W/
LRFD, W
L/360
Arc Spot Weld 1/2" Effective Dia
PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

8'-6"

370
591
-

ASD & LRFD - Superimposed Load, W (psf)


324 287 254 227 204 183 165 150
519 458 407 363 326 293 264 239
-

9'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


1925 1887 1853 1844 1815 1789
1643 1621 1601 1606 1589 1574
1622 1601 1583 1588 1572 1558
1606 1586 1568 1575 1559 1546

18

83
138
83

Attachment Pattern
1744 1724 1723
1547 1536 1542
1533 1522 1529
1522 1511 1518

1706
1532
1519
1509

1689
1522
1509
1500

1674
1513
1501
1492

1660
1504
1493
1484

1647
1497
1485
1477

Mno/= 39.8 kip-in/ft


Mno= 60.8 kip-in/ft

409
654
-

ASD & LRFD - Superimposed Load, W (psf)


359 318 282 252 226 204 184 167
575 508 452 404 362 326 295 267
-

9'-0"

8'-6"

ASD, W/
LRFD, W
L/360

500
800
-

440
704
-

36/4
1833
1601
1583
1572

150
243
150

134
221
134

119
202
119

107
185
107

96
170
96

87
156
87

Attachment Pattern
1809 1786 1786
1586 1573 1582
1570 1557 1567
1558 1546 1556

1766
1569
1555
1545

1748
1558
1544
1535

1731
1548
1534
1525

1715
1538
1525
1516

1700
1529
1516
1508

Mno/= 43.7 kip-in/ft


Mno= 66.9 kip-in/ft

Icr = 71.7 in4/ft


Iu = 118.3 in4/ft
9'-0"

Vn/ = 3.05 kip/ft


Vn = 6.09 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

ASD & LRFD - Superimposed Load, W (psf)


389 347 310 279 242 212 187
623 555 496 446 403 365 331
279 242 212 187
36/4
2006
1705
1674
1673

147
276
147

131
253
131

118
232
118

106
213
106

96
197
96

Attachment Pattern
1974 1944 1950
1686 1668 1685
1655 1639 1657
1655 1638 1656

1923
1669
1642
1641

1899
1653
1627
1627

1876
1639
1614
1614

1854
1626
1602
1601

1835
1614
1591
1590

Mno/= 52.9 kip-in/ft


Mno= 80.9 kip-in/ft

Icr = 83.2 in4/ft


Iu = 125.8 in4/ft

Vn/ = 3.05 kip/ft


Vn = 6.09 kip/ft

D PANEL

LRFD - Diaphragm Shear, Sn (plf / ft)


2235 2177 2126 2124 2081 2042
1821 1788 1758 1776 1750 1727
1777 1747 1719 1739 1715 1693
1776 1746 1718 1738 1714 1692

165
302
165

C PANELS

8'-0"

Vn/ = 3.05 kip/ft


Vn = 6.09 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


2013 1969 1930 1923 1890 1860
1693 1668 1645 1653 1634 1616
1670 1646 1625 1634 1615 1599
1653 1630 1610 1620 1602 1586

Concrete + Deck = 36.1 psf


(Icr+Iu)/2 = 104.5 in4/ft

LRFD - Diaphragm Shear, Sn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width

3/4" Welded Shear Studs


12 in o.c.
24 in o.c.
36 in o.c.

www.ascsd.com

6x6 W1.4xW1.4

As = 0.028 in2/ft
2700
2700
2700

6x6 W2.9xW2.9

As = 0.058 in2/ft
4050
4050
4050

6x6 W4.0xW4.0

As = 0.080 in2/ft
5040
5040
5040

4x4 W4xW4

As = 0.120 in2/ft
6840
6840
5170

4x4 W6xW6

As = 0.180 in2/ft
9540
7750
5170

Composite and Non-Composite Deck Catalog May 2014

ACUSTADEK

All Gages

92
151
92

8'-6"

Vertical Load Span (in)

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

102
165
102

8'-0"

Concrete + Deck = 35.4 psf


(Icr+Iu)/2 = 95.03 in4/ft

16

113
180
-

N PANELS

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

124
198
-

B PANELS

ASD, W/
LRFD, W
L/360

36/4
1766
1560
1545
1533

136
217
-

Icr = 66.5 in4/ft


Iu = 115.1 in4/ft

Concrete + Deck = 35.1 psf


(Icr+Iu)/2 = 90.82 in4/ft
Vertical Load Span (in)

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

2W PANELS

19

8'-0"

3W PANELS

GA

GENERAL INFORMATION

73

TABLE OF CONTENTS

2.4 3WH-36 Composite Deck

5 12" Total Slab Depth


Light Weight Concrete (110 pcf)

Gage
22
21
20
GA

22

Concrete Volume 1.235yd3/100ft2


1 Hour Fire Rating

Single
10' - 3"
11' - 6"
11' - 10"

Maximum Unshored Span (in)


Triple
Gage
11' - 10"
19
12' - 11"
18
13' - 5"
16

Double
11' - 5"
12' - 6"
12' - 11"

Vertical Load Span (in)

8'-0"

8'-6"

ASD, W/
LRFD, W
L/360

306
489
-

268
428
-

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

9'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


2034 2009 1986 1977 1958 1941
1845 1831 1818 1817 1807 1797
1831 1817 1805 1805 1795 1786
1817 1804 1793 1794 1784 1775

ASD, W/
LRFD, W
L/360
21

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

80
128
-

73
116
-

66
106
-

Attachment Pattern
1911 1898 1895
1780 1772 1774
1770 1763 1764
1760 1754 1756

1883
1767
1758
1750

1873
1761
1752
1744

1863
1755
1747
1739

1854
1750
1742
1734

1846
1745
1737
1730

Mno/= 33.6 kip-in/ft


Mno= 51.5 kip-in/ft

346
554
-

8'-6"

ASD, W/
LRFD, W
L/360

366
585
-

321
513
-

36/4
1974
1816
1804
1793

124
199
-

113
180
-

102
164
-

93
149
-

85
136
-

77
124
-

Attachment Pattern
1958 1943 1940
1807 1798 1801
1795 1787 1790
1785 1777 1781

1926
1793
1783
1774

1914
1786
1776
1767

1903
1779
1769
1761

1893
1773
1764
1755

1883
1767
1758
1750

Mno/= 37.7 kip-in/ft


Mno= 57.7 kip-in/ft

Icr = 72.6 in4/ft


Iu = 143.4 in4/ft
9'-0"

Vn/ = 3.01 kip/ft


Vn = 4.34 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


2099 2069 2043 2033 2012 1992
1881 1865 1850 1851 1838 1827
1865 1849 1835 1836 1825 1814
1850 1835 1822 1824 1813 1803

Vn/ = 3.51 kip/ft


Vn = 5.15 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

ASD & LRFD - Superimposed Load, W (psf)


283 251 223 200 179 162 146
452 401 357 320 287 259 234
-

LRFD - Diaphragm Shear, Sn (plf / ft)


2131 2100 2072 2063 2039 2018
1900 1882 1866 1868 1854 1842
1882 1865 1851 1853 1840 1828
1867 1851 1837 1840 1828 1817

Concrete + Deck = 39.4 psf


(Icr+Iu)/2 = 110.4 in4/ft

74

88
141
-

ASD & LRFD - Superimposed Load, W (psf)


303 267 237 211 188 169 152 137
485 428 379 337 302 271 244 220
-

8'-0"

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

98
156
-

8'-6"

Vertical Load Span (in)

Triple
14' - 6"
14' - 11"
15' - 8"

108
173
-

8'-0"

Concrete + Deck = 39.3 psf


(Icr+Iu)/2 = 108 in4/ft

20

36/4
1925
1788
1777
1767

Icr = 66.2 in4/ft


Iu = 139.8 in4/ft
9'-0"

Double
14' - 3"
15' - 0"
16' - 8"

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

ASD & LRFD - Superimposed Load, W (psf)


236 208 185 165 148 133 120
377 333 296 264 237 213 191
-

Concrete + Deck = 39.1 psf


(Icr+Iu)/2 = 103 in4/ft
Vertical Load Span (in)

Single
12' - 5"
12' - 8"
13' - 5"

36/4
1999
1831
1818
1807

Icr = 75.7 in4/ft


Iu = 145.1 in4/ft

Composite and Non-Composite Deck Catalog May 2014

132
212
-

120
192
-

109
175
-

99
159
-

91
145
-

83
133
-

Attachment Pattern
1982 1966 1963
1821 1811 1815
1808 1800 1803
1798 1790 1794

1949
1806
1795
1786

1936
1798
1788
1779

1924
1791
1781
1773

1912
1785
1775
1767

1902
1778
1769
1761

Mno/= 39.7 kip-in/ft


Mno= 60.7 kip-in/ft

Vn/ = 3.51 kip/ft


Vn = 5.64 kip/ft

www.ascsd.com

TABLE OF CONTENTS

5 12" Total Slab Depth


Light Weight Concrete (110 pcf)

Concrete Volume 1.235yd3/100ft2


1 Hour Fire Rating

Vertical Load Span (in)


ASD, W/
LRFD, W
L/360
Arc Spot Weld 1/2" Effective Dia
PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

8'-6"

433
692
-

ASD & LRFD - Superimposed Load, W (psf)


380 336 298 266 239 215 194 176
608 537 477 426 382 344 310 281
-

9'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


2250 2211 2177 2168 2139 2113
1967 1945 1925 1930 1913 1898
1946 1925 1907 1912 1896 1882
1930 1910 1892 1899 1884 1870

18

102
163
-

Attachment Pattern
2068 2048 2047
1871 1860 1866
1857 1846 1853
1846 1835 1842

2030
1856
1843
1833

2013
1846
1833
1824

1998
1837
1825
1816

1984
1828
1817
1808

1971
1821
1809
1801

Mno/= 46.4 kip-in/ft


Mno= 71.0 kip-in/ft

479
766
-

ASD & LRFD - Superimposed Load, W (psf)


421 372 331 296 265 239 216 196
673 595 529 473 425 383 346 314
-

9'-0"

8'-6"

ASD, W/
LRFD, W
L/360

585
936
-

515
824
-

36/4
2157
1925
1908
1896

178
285
-

163
260
-

149
238
-

136
218
-

125
200
-

113
183
113

Attachment Pattern
2133 2110 2111
1910 1897 1906
1894 1881 1891
1882 1870 1880

2091
1893
1879
1869

2072
1882
1868
1859

2055
1872
1858
1849

2039
1862
1849
1840

2024
1853
1840
1832

Mno/= 51.1 kip-in/ft


Mno= 78.2 kip-in/ft

Icr = 92.5 in4/ft


Iu = 155.0 in4/ft
9'-0"

Vn/ = 3.51 kip/ft


Vn = 7.02 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

ASD & LRFD - Superimposed Load, W (psf)


456 406 364 327 295 267 243
730 650 582 523 472 428 389
243
36/4
2330
2029
1998
1997

191
324
191

170
297
170

153
273
153

138
251
138

124
231
124

Attachment Pattern
2298 2268 2274
2010 1992 2009
1979 1963 1981
1979 1962 1980

2247
1993
1966
1965

2223
1977
1952
1951

2200
1963
1938
1938

2178
1950
1926
1925

2159
1938
1915
1914

Mno/= 61.8 kip-in/ft


Mno= 94.6 kip-in/ft

Icr = 107.3 in4/ft


Iu = 164.3 in4/ft

Vn/ = 3.51 kip/ft


Vn = 7.02 kip/ft

D PANEL

LRFD - Diaphragm Shear, Sn (plf / ft)


2559 2501 2450 2448 2405 2366
2145 2112 2082 2100 2074 2051
2101 2071 2043 2063 2039 2017
2100 2070 2043 2062 2038 2017

215
355
215

C PANELS

8'-0"

Vn/ = 3.51 kip/ft


Vn = 7.02 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


2337 2293 2254 2247 2214 2184
2017 1992 1970 1977 1958 1941
1994 1970 1949 1958 1939 1923
1977 1954 1934 1944 1926 1910

Concrete + Deck = 40.8 psf


(Icr+Iu)/2 = 135.8 in4/ft

LRFD - Diaphragm Shear, Sn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width

3/4" Welded Shear Studs


12 in o.c.
24 in o.c.
36 in o.c.

www.ascsd.com

6x6 W1.4xW1.4

As = 0.028 in2/ft
3070
3070
3070

6x6 W2.9xW2.9

As = 0.058 in2/ft
4420
4420
4420

6x6 W4.0xW4.0

As = 0.080 in2/ft
5410
5410
5170

4x4 W4xW4

As = 0.120 in2/ft
7210
7210
5170

4x4 W6xW6

As = 0.180 in2/ft
9910
7750
5170

Composite and Non-Composite Deck Catalog May 2014

ACUSTADEK

All Gages

111
178
-

8'-6"

Vertical Load Span (in)

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

121
194
-

8'-0"

Concrete + Deck = 40.1 psf


(Icr+Iu)/2 = 123.8 in4/ft

16

133
212
-

N PANELS

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

145
232
-

B PANELS

ASD, W/
LRFD, W
L/360

36/4
2090
1884
1869
1857

160
255
-

Icr = 85.8 in4/ft


Iu = 151.0 in4/ft

Concrete + Deck = 39.8 psf


(Icr+Iu)/2 = 118.4 in4/ft
Vertical Load Span (in)

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

2W PANELS

19

8'-0"

3W PANELS

GA

3WH-36 Composite Deck 2.4

GENERAL INFORMATION

75

TABLE OF CONTENTS

2.4 3WH-36 Composite Deck


6" Total Slab Depth
Light Weight Concrete (110 pcf)

Gage
22
21
20
GA

22

Concrete Volume 1.389yd3/100ft2

Single
9' - 10"
11' - 1"
11' - 6"

Maximum Unshored Span (in)


Triple
Gage
11' - 5"
19
12' - 5"
18
12' - 11"
16

Double
11' - 0"
12' - 0"
12' - 6"

Vertical Load Span (in)

8'-0"

8'-6"

ASD, W/
LRFD, W
L/360

353
565
-

309
494
-

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

9'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


2358 2333 2310 2301 2282 2265
2169 2155 2142 2142 2131 2121
2155 2141 2129 2129 2119 2110
2141 2128 2117 2118 2108 2099

ASD, W/
LRFD, W
L/360
21

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

93
149
-

85
135
-

77
123
-

Attachment Pattern
2235 2222 2219
2104 2097 2098
2094 2087 2088
2084 2078 2080

2207
2091
2082
2074

2197
2085
2076
2068

2187
2079
2071
2063

2178
2074
2066
2058

2170
2069
2061
2054

Mno/= 38.7 kip-in/ft


Mno= 59.2 kip-in/ft

399
639
-

8'-6"

ASD, W/
LRFD, W
L/360

422
675
-

370
592
-

36/4
2298
2140
2128
2117

144
230
-

131
209
-

119
190
-

108
173
-

99
158
-

90
144
-

Attachment Pattern
2282 2267 2264
2131 2122 2125
2119 2111 2114
2109 2101 2105

2251
2117
2107
2098

2238
2110
2100
2091

2227
2103
2094
2085

2217
2097
2088
2080

2207
2091
2082
2074

Mno/= 43.4 kip-in/ft


Mno= 66.4 kip-in/ft

Icr = 91.7 in4/ft


Iu = 184.4 in4/ft
9'-0"

Vn/ = 3.30 kip/ft


Vn = 4.78 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


2423 2393 2367 2357 2336 2316
2205 2189 2174 2175 2162 2151
2189 2173 2159 2161 2149 2138
2174 2159 2146 2148 2137 2127

Vn/ = 3.90 kip/ft


Vn = 5.59 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

ASD & LRFD - Superimposed Load, W (psf)


326 290 258 231 208 187 169
522 463 413 370 332 299 271
-

LRFD - Diaphragm Shear, Sn (plf / ft)


2455 2424 2396 2387 2363 2342
2224 2206 2190 2192 2178 2166
2206 2190 2175 2177 2164 2152
2191 2175 2161 2164 2152 2141

Concrete + Deck = 44.1 psf


(Icr+Iu)/2 = 141.1 in4/ft

76

103
164
-

ASD & LRFD - Superimposed Load, W (psf)


350 309 274 244 218 196 176 159
560 494 438 390 349 313 282 255
-

8'-0"

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

113
181
-

8'-6"

Vertical Load Span (in)

Triple
14' - 1"
14' - 6"
15' - 3"

125
200
-

8'-0"

Concrete + Deck = 44.0 psf


(Icr+Iu)/2 = 138.1 in4/ft

20

36/4
2249
2112
2101
2091

Icr = 83.5 in4/ft


Iu = 180.0 in4/ft
9'-0"

Double
13' - 9"
14' - 6"
16' - 2"

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

ASD & LRFD - Superimposed Load, W (psf)


272 241 214 191 171 154 139
435 385 342 306 274 246 222
-

Concrete + Deck = 43.8 psf


(Icr+Iu)/2 = 131.8 in4/ft
Vertical Load Span (in)

Single
12' - 1"
12' - 4"
13' - 1"

36/4
2323
2155
2142
2131

Icr = 95.6 in4/ft


Iu = 186.6 in4/ft

Composite and Non-Composite Deck Catalog May 2014

153
245
-

139
223
-

127
203
-

116
185
-

105
169
-

96
154
-

Attachment Pattern
2306 2290 2287
2145 2135 2139
2132 2124 2127
2122 2114 2118

2273
2130
2119
2110

2260
2123
2112
2103

2248
2115
2105
2097

2236
2109
2099
2091

2226
2102
2093
2085

Mno/= 45.7 kip-in/ft


Mno= 69.9 kip-in/ft

Vn/ = 4.09 kip/ft


Vn = 6.07 kip/ft

www.ascsd.com

TABLE OF CONTENTS

3WH-36 Composite Deck 2.4


6" Total Slab Depth
Light Weight Concrete (110 pcf)

Concrete Volume 1.389yd3/100ft2


Vertical Load Span (in)


ASD, W/
LRFD, W
L/360
Arc Spot Weld 1/2" Effective Dia
PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

8'-6"

500
799
-

ASD & LRFD - Superimposed Load, W (psf)


439 388 345 308 276 249 225 204
702 620 551 492 442 398 359 326
-

9'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


2574 2535 2501 2492 2463 2437
2291 2269 2249 2254 2237 2222
2270 2249 2231 2236 2220 2206
2254 2234 2216 2223 2208 2194

18

118
189
-

Attachment Pattern
2392 2372 2371
2196 2184 2190
2181 2170 2177
2170 2159 2166

2354
2180
2167
2157

2337
2170
2158
2148

2322
2161
2149
2140

2308
2153
2141
2132

2295
2145
2133
2125

Mno/= 53.5 kip-in/ft


Mno= 81.9 kip-in/ft

553
885
-

ASD & LRFD - Superimposed Load, W (psf)


486 430 383 342 307 277 250 227
778 688 612 547 491 443 401 364
-

9'-0"

8'-6"

ASD, W/
LRFD, W
L/360

677
1083
-

596
953
-

36/4
2482
2249
2232
2220

207
331
-

189
302
-

172
276
-

158
253
-

145
232
-

133
213
-

Attachment Pattern
2457 2434 2435
2234 2221 2230
2218 2205 2215
2206 2194 2204

2415
2218
2203
2193

2396
2206
2192
2183

2379
2196
2182
2173

2363
2186
2173
2164

2348
2177
2165
2156

Mno/= 58.9 kip-in/ft


Mno= 90.1 kip-in/ft

Icr = 117.1 in4/ft


Iu = 198.8 in4/ft
9'-0"

Vn/ = 4.09 kip/ft


Vn = 8.18 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

ASD & LRFD - Superimposed Load, W (psf)


527 470 421 379 342 310 282
844 752 673 606 547 496 451
36/4
2654
2353
2322
2321

235
376
-

216
345
-

195
317
195

175
292
175

158
269
158

Attachment Pattern
2622 2592 2598
2334 2316 2333
2304 2287 2305
2303 2286 2304

2571
2317
2290
2289

2547
2302
2276
2275

2524
2287
2262
2262

2503
2274
2250
2250

2483
2262
2239
2238

Mno/= 71.4 kip-in/ft


Mno= 109.2 kip-in/ft

Icr = 135.8 in4/ft


Iu = 210.3 in4/ft

Vn/ = 4.09 kip/ft


Vn = 8.18 kip/ft

D PANEL

LRFD - Diaphragm Shear, Sn (plf / ft)


2883 2825 2774 2773 2729 2690
2469 2436 2406 2424 2398 2375
2425 2395 2368 2387 2363 2341
2424 2394 2367 2386 2362 2341

257
411
-

C PANELS

8'-0"

Vn/ = 4.09 kip/ft


Vn = 8.12 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


2661 2617 2578 2571 2538 2509
2341 2316 2294 2301 2282 2265
2318 2294 2273 2282 2263 2247
2301 2278 2258 2268 2250 2234

Concrete + Deck = 45.4 psf


(Icr+Iu)/2 = 173 in4/ft

LRFD - Diaphragm Shear, Sn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width

3/4" Welded Shear Studs


12 in o.c.
24 in o.c.
36 in o.c.

www.ascsd.com

6x6 W1.4xW1.4

As = 0.028 in2/ft
3440
3440
3440

6x6 W2.9xW2.9

As = 0.058 in2/ft
4790
4790
4790

6x6 W4.0xW4.0

As = 0.080 in2/ft
5780
5780
5170

4x4 W4xW4

As = 0.120 in2/ft
7580
7580
5170

4x4 W6xW6

As = 0.180 in2/ft
10280
7750
5170

Composite and Non-Composite Deck Catalog May 2014

ACUSTADEK

All Gages

129
206
-

8'-6"

Vertical Load Span (in)

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

141
225
-

8'-0"

Concrete + Deck = 44.8 psf


(Icr+Iu)/2 = 158 in4/ft

16

154
246
-

N PANELS

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

168
270
-

B PANELS

ASD, W/
LRFD, W
L/360

36/4
2414
2208
2193
2181

185
296
-

Icr = 108.5 in4/ft


Iu = 193.9 in4/ft

Concrete + Deck = 44.5 psf


(Icr+Iu)/2 = 151.2 in4/ft
Vertical Load Span (in)

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

2W PANELS

19

8'-0"

3W PANELS

GA

GENERAL INFORMATION

77

TABLE OF CONTENTS

2.4 3WH-36 Composite Deck

6 14" Total Slab Depth


Light Weight Concrete (110 pcf)

Gage
22
21
20
GA

22

Concrete Volume 1.466yd3/100ft2


2 Hour Fire Rating

Single
9' - 8"
10' - 10"
11' - 5"

Maximum Unshored Span (in)


Triple
Gage
11' - 2"
19
12' - 2"
18
12' - 8"
16

Double
10' - 10"
11' - 10"
12' - 3"

Vertical Load Span (in)

8'-0"

8'-6"

ASD, W/
LRFD, W
L/360

377
603
-

330
528
-

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

9'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


2520 2495 2472 2463 2444 2427
2331 2317 2304 2304 2293 2283
2317 2303 2291 2291 2281 2272
2303 2290 2279 2280 2270 2261

ASD, W/
LRFD, W
L/360
21

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

100
160
-

91
145
-

83
132
-

Attachment Pattern
2397 2384 2381
2266 2259 2260
2256 2249 2250
2246 2240 2242

2369
2253
2244
2236

2359
2247
2238
2230

2349
2241
2233
2225

2340
2236
2228
2220

2332
2231
2223
2216

Mno/= 41.3 kip-in/ft


Mno= 63.2 kip-in/ft

427
683
-

8'-6"

ASD, W/
LRFD, W
L/360

451
722
-

396
633
-

36/4
2460
2302
2290
2279

154
247
-

140
224
-

127
204
-

116
186
-

106
169
-

97
154
-

Attachment Pattern
2444 2429 2426
2293 2284 2287
2281 2273 2276
2271 2263 2267

2413
2279
2269
2260

2400
2272
2262
2253

2389
2265
2256
2247

2379
2259
2250
2242

2369
2253
2244
2236

Mno/= 46.3 kip-in/ft


Mno= 70.9 kip-in/ft

Icr = 102.3 in4/ft


Iu = 207.7 in4/ft
9'-0"

Vn/ = 3.47 kip/ft


Vn = 5.03 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


2585 2555 2529 2519 2498 2478
2367 2351 2336 2337 2324 2313
2351 2335 2321 2323 2311 2300
2336 2321 2308 2310 2299 2289

Vn/ = 4.06 kip/ft


Vn = 5.83 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

ASD & LRFD - Superimposed Load, W (psf)


349 310 276 247 222 200 181
559 496 442 396 356 321 290
-

LRFD - Diaphragm Shear, Sn (plf / ft)


2617 2586 2558 2549 2525 2504
2386 2368 2352 2354 2340 2328
2368 2352 2337 2339 2326 2315
2353 2337 2323 2326 2314 2303

Concrete + Deck = 46.4 psf


(Icr+Iu)/2 = 158.4 in4/ft

78

110
176
-

ASD & LRFD - Superimposed Load, W (psf)


374 330 293 261 233 209 189 170
599 528 468 417 373 335 302 273
-

8'-0"

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

121
194
-

8'-6"

Vertical Load Span (in)

Triple
13' - 11"
14' - 4"
15' - 1"

134
214
-

8'-0"

Concrete + Deck = 46.3 psf


(Icr+Iu)/2 = 155 in4/ft

20

36/4
2411
2274
2263
2253

Icr = 93.2 in4/ft


Iu = 202.9 in4/ft
9'-0"

Double
13' - 6"
14' - 3"
15' - 10"

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

ASD & LRFD - Superimposed Load, W (psf)


291 257 229 204 183 165 148
465 412 366 327 293 263 237
-

Concrete + Deck = 46.1 psf


(Icr+Iu)/2 = 148 in4/ft
Vertical Load Span (in)

Single
11' - 11"
12' - 3"
12' - 11"

36/4
2485
2317
2304
2293

Icr = 106.7 in4/ft


Iu = 210.1 in4/ft

Composite and Non-Composite Deck Catalog May 2014

164
263
-

149
239
-

136
217
-

124
198
-

113
181
-

103
165
-

Attachment Pattern
2468 2452 2449
2307 2297 2301
2294 2286 2289
2284 2276 2280

2435
2292
2281
2272

2422
2285
2274
2265

2410
2277
2267
2259

2398
2271
2261
2253

2388
2264
2255
2247

Mno/= 48.8 kip-in/ft


Mno= 74.6 kip-in/ft

Vn/ = 4.42 kip/ft


Vn = 6.32 kip/ft

www.ascsd.com

TABLE OF CONTENTS

6 14" Total Slab Depth


Light Weight Concrete (110 pcf)

Concrete Volume 1.466yd3/100ft2


2 Hour Fire Rating

Vertical Load Span (in)


ASD, W/
LRFD, W
L/360
Arc Spot Weld 1/2" Effective Dia
PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

8'-6"

534
855
-

ASD & LRFD - Superimposed Load, W (psf)


469 415 369 329 295 266 240 218
751 664 590 527 473 426 385 349
-

9'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


2736 2697 2663 2654 2625 2599
2453 2431 2411 2416 2399 2384
2432 2411 2393 2398 2383 2368
2416 2396 2378 2385 2370 2356

18

16

Attachment Pattern
2554 2534 2533
2358 2346 2352
2343 2332 2339
2332 2321 2328

2516
2342
2329
2319

2499
2332
2320
2310

2484
2323
2311
2302

2471
2315
2303
2294

2457
2307
2295
2287

Mno/= 57.2 kip-in/ft


Mno= 87.5 kip-in/ft

8'-6"

592
947
-

ASD & LRFD - Superimposed Load, W (psf)


520 460 409 366 329 296 268 243
832 736 655 586 526 474 429 389
-

9'-0"

8'-0"

8'-6"

724 637
1159 1020
-

36/4
2644
2411
2394
2382

222
354
-

202
323
-

185
296
-

169
271
-

156
249
-

143
229
-

Attachment Pattern
2619 2596 2597
2396 2383 2392
2380 2367 2377
2368 2356 2366

2577
2380
2365
2355

2558
2368
2354
2345

2541
2358
2344
2335

2525
2348
2335
2326

2510
2339
2327
2318

Mno/= 63.0 kip-in/ft


Mno= 96.3 kip-in/ft

Icr = 130.7 in4/ft


Iu = 223.7 in4/ft
9'-0"

Vn/ = 4.42 kip/ft


Vn = 8.36 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


2823 2779 2740 2733 2700 2671
2503 2478 2456 2464 2444 2427
2480 2456 2435 2444 2425 2409
2463 2440 2420 2430 2412 2396

Vn/ = 4.42 kip/ft


Vn = 8.84 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

ASD & LRFD - Superimposed Load, W (psf)


565 503 451 405 366 332 302
904 805 721 649 586 531 483
-

LRFD - Diaphragm Shear, Sn (plf / ft)


3045 2987 2936 2935 2891 2852
2631 2598 2568 2586 2560 2537
2587 2557 2530 2549 2525 2503
2586 2556 2529 2548 2524 2503

Concrete + Deck = 47.8 psf


(Icr+Iu)/2 = 194 in4/ft

36/4
2816
2515
2484
2483

275
441
-

252
403
-

231
370
-

212
340
-

196
313
-

178
289
178

Attachment Pattern
2784 2754 2760
2496 2478 2495
2466 2449 2467
2465 2448 2466

2733
2479
2452
2451

2709
2464
2438
2437

2686
2449
2424
2424

2665
2436
2412
2412

2645
2424
2401
2400

Mno/= 76.3 kip-in/ft


Mno= 116.7 kip-in/ft

Icr = 151.7 in4/ft


Iu = 236.4 in4/ft

Vn/ = 4.42 kip/ft


Vn = 8.84 kip/ft

LRFD - Diaphragm Shear, Sn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width

3/4" Welded Shear Studs


12 in o.c.
24 in o.c.
36 in o.c.

www.ascsd.com

6x6 W1.4xW1.4

As = 0.028 in2/ft
n/a
n/a
n/a

6x6 W2.9xW2.9

As = 0.058 in2/ft
4980
4980
4980

6x6 W4.0xW4.0

As = 0.080 in2/ft
5970
5970
5170

4x4 W4xW4

As = 0.120 in2/ft
7770
7750
5170

4x4 W6xW6

As = 0.180 in2/ft
10470
7750
5170

Composite and Non-Composite Deck Catalog May 2014

ACUSTADEK

All Gages

127
203
-

D PANEL

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

138
221
-

C PANELS

ASD, W/
LRFD, W
L/360

151
241
-

8'-0"

Concrete + Deck = 47.1 psf


(Icr+Iu)/2 = 177.2 in4/ft
Vertical Load Span (in)

165
264
-

N PANELS

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

181
289
-

B PANELS

ASD, W/
LRFD, W
L/360

36/4
2576
2370
2355
2343

198
317
-

Icr = 121.2 in4/ft


Iu = 218.2 in4/ft

Concrete + Deck = 46.8 psf


(Icr+Iu)/2 = 169.7 in4/ft
Vertical Load Span (in)

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

2W PANELS

19

8'-0"

3W PANELS

GA

3WH-36 Composite Deck 2.4

GENERAL INFORMATION

79

TABLE OF CONTENTS

2.4 3WH-36 Composite Deck


7 316" Total Slab Depth
Light Weight Concrete (110 pcf)

Gage
22
21
20
GA

22

Concrete Volume 1.755yd3/100ft2


3 Hour Fire Rating

Single
9' - 0"
10' - 2"
10' - 8"

Maximum Unshored Span (in)


Triple
Gage
10' - 6"
19
11' - 6"
18
11' - 11"
16

Double
10' - 2"
11' - 1"
11' - 7"

Vertical Load Span (in)

8'-0"

8'-6"

ASD, W/
LRFD, W
L/360

472
754
-

413
661
-

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

9'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


3128 3102 3080 3070 3051 3034
2939 2925 2912 2911 2900 2891
2924 2911 2899 2899 2889 2879
2911 2898 2887 2887 2878 2869

ASD, W/
LRFD, W
L/360
21

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

126
202
-

115
184
-

105
167
-

Attachment Pattern
3005 2992 2988
2874 2866 2867
2863 2856 2858
2854 2847 2849

2977
2861
2852
2843

2967
2855
2846
2838

2957
2849
2841
2833

2948
2844
2836
2828

2939
2839
2831
2824

Mno/= 51.5 kip-in/ft


Mno= 78.7 kip-in/ft

534
855
-

8'-6"

ASD, W/
LRFD, W
L/360

565
904
-

496
793
-

36/4
3068
2910
2898
2887

194
311
-

177
283
-

161
257
-

147
235
-

134
214
-

122
196
-

Attachment Pattern
3051 3037 3033
2900 2892 2894
2889 2881 2884
2879 2871 2874

3020
2887
2876
2867

3008
2879
2869
2861

2997
2873
2863
2855

2986
2866
2857
2849

2976
2861
2852
2844

Mno/= 57.8 kip-in/ft


Mno= 88.4 kip-in/ft

Icr = 148.6 in4/ft


Iu = 313.5 in4/ft
9'-0"

Vn/ = 4.09 kip/ft


Vn = 5.95 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


3192 3163 3137 3127 3105 3086
2975 2958 2944 2944 2932 2920
2958 2943 2929 2930 2918 2908
2944 2929 2916 2918 2907 2896

Vn/ = 4.68 kip/ft


Vn = 6.76 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

ASD & LRFD - Superimposed Load, W (psf)


438 388 347 311 279 252 228
700 622 555 497 447 403 365
-

LRFD - Diaphragm Shear, Sn (plf / ft)


3225 3194 3166 3156 3133 3112
2994 2976 2960 2961 2948 2936
2976 2959 2944 2946 2934 2922
2961 2945 2931 2934 2922 2911

Concrete + Deck = 55.2 psf


(Icr+Iu)/2 = 235.9 in4/ft

80

139
222
-

ASD & LRFD - Superimposed Load, W (psf)


468 413 367 327 293 263 237 214
749 661 587 523 468 421 379 343
-

8'-0"

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

153
245
-

8'-6"

Vertical Load Span (in)

Triple
13' - 1"
13' - 9"
14' - 6"

169
270
-

8'-0"

Concrete + Deck = 55.1 psf


(Icr+Iu)/2 = 231 in4/ft

20

36/4
3019
2882
2871
2861

Icr = 135.1 in4/ft


Iu = 306.6 in4/ft
9'-0"

Double
12' - 8"
13' - 5"
14' - 11"

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

ASD & LRFD - Superimposed Load, W (psf)


364 322 287 256 230 207 187
582 516 459 410 368 331 299
-

Concrete + Deck = 54.9 psf


(Icr+Iu)/2 = 220.9 in4/ft
Vertical Load Span (in)

Single
11' - 5"
11' - 9"
12' - 5"

36/4
3093
2924
2912
2901

Icr = 155.0 in4/ft


Iu = 316.8 in4/ft

Composite and Non-Composite Deck Catalog May 2014

207
331
-

188
301
-

171
274
-

157
250
-

143
229
-

131
210
-

Attachment Pattern
3075 3059 3056
2914 2905 2908
2902 2893 2897
2892 2883 2887

3042
2900
2889
2880

3029
2892
2882
2873

3017
2885
2875
2866

3006
2878
2869
2860

2996
2872
2863
2855

Mno/= 60.9 kip-in/ft


Mno= 93.1 kip-in/ft

Vn/ = 5.04 kip/ft


Vn = 7.25 kip/ft

www.ascsd.com

TABLE OF CONTENTS

7 316" Total Slab Depth


Light Weight Concrete (110 pcf)

Concrete Volume 1.755yd3/100ft2


3 Hour Fire Rating

Vertical Load Span (in)


ASD, W/
LRFD, W
L/360
Arc Spot Weld 1/2" Effective Dia
PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

8'-6"

670
1072
-

ASD & LRFD - Superimposed Load, W (psf)


589 521 463 414 371 335 303 275
942 833 741 662 594 536 484 439
-

9'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


3343 3305 3270 3262 3233 3207
3061 3039 3019 3024 3007 2992
3040 3019 3000 3006 2990 2976
3023 3004 2986 2992 2977 2963

18

16

9'-0"

Attachment Pattern
3162 3142 3141
2965 2954 2960
2951 2940 2946
2939 2929 2936

3123
2949
2936
2926

3107
2940
2927
2918

3092
2931
2919
2909

3078
2922
2911
2902

3065
2914
2903
2894

Mno/= 71.4 kip-in/ft


Mno= 109.3 kip-in/ft

8'-0"

8'-6"

36/4
3251
3018
3001
2989

279
447
-

255
408
-

234
374
-

214
343
-

197
315
-

181
290
-

Attachment Pattern
3226 3204 3204
3004 2990 2999
2987 2975 2984
2976 2964 2974

3184
2987
2973
2963

3166
2976
2962
2952

3148
2965
2952
2943

3132
2956
2943
2934

3117
2947
2934
2925

Mno/= 78.8 kip-in/ft


Mno= 120.5 kip-in/ft

Icr = 190.6 in4/ft


Iu = 336.2 in4/ft
9'-0"

Vn/ = 5.66 kip/ft


Vn = 9.29 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


3431 3387 3348 3341 3308 3278
3111 3086 3063 3071 3052 3034
3087 3063 3042 3051 3033 3016
3071 3048 3028 3038 3020 3004

Vn/ = 5.66 kip/ft


Vn = 10.57 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

ASD & LRFD - Superimposed Load, W (psf)


911 802 711 634 568 511 462 419 381
1458 1284 1138 1014 909 818 739 670 610
LRFD - Diaphragm Shear, Sn (plf / ft)
3652 3595 3544 3542 3499 3460
3239 3206 3176 3194 3168 3144
3195 3164 3137 3157 3133 3111
3194 3163 3136 3156 3132 3110

Concrete + Deck = 56.5 psf


(Icr+Iu)/2 = 288 in4/ft

36/4
3424
3123
3091
3090

348
557
-

319
510
-

292
468
-

269
430
-

248
397
-

229
366
-

Attachment Pattern
3391 3362 3368
3104 3086 3103
3073 3057 3075
3072 3056 3074

3341
3086
3059
3059

3316
3071
3045
3045

3293
3057
3032
3031

3272
3044
3020
3019

3252
3032
3008
3008

Mno/= 95.7 kip-in/ft


Mno= 146.5 kip-in/ft

Icr = 221.8 in4/ft


Iu = 354.2 in4/ft

Vn/ = 5.66 kip/ft


Vn = 11.31 kip/ft

LRFD - Diaphragm Shear, Sn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width

3/4" Welded Shear Studs


12 in o.c.
24 in o.c.
36 in o.c.

www.ascsd.com

6x6 W1.4xW1.4

As = 0.028 in2/ft
n/a
n/a
n/a

6x6 W2.9xW2.9

As = 0.058 in2/ft
5670
5670
5170

6x6 W4.0xW4.0

As = 0.080 in2/ft
6660
6660
5170

4x4 W4xW4

As = 0.120 in2/ft
8460
7750
5170

4x4 W6xW6

As = 0.180 in2/ft
11160
7750
5170

Composite and Non-Composite Deck Catalog May 2014

ACUSTADEK

All Gages

161
257
-

D PANEL

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

175
280
-

C PANELS

ASD, W/
LRFD, W
L/360

191
305
-

ASD & LRFD - Superimposed Load, W (psf)


743 653 578 515 460 414 373 338 307
1188 1045 925 823 736 662 597 541 491
-

Concrete + Deck = 55.9 psf


(Icr+Iu)/2 = 263.4 in4/ft
Vertical Load Span (in)

208
333
-

N PANELS

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

8'-6"

228
365
-

B PANELS

ASD, W/
LRFD, W
L/360

8'-0"

36/4
3183
2978
2963
2951

250
400
-

Icr = 176.4 in4/ft


Iu = 328.3 in4/ft

Concrete + Deck = 55.6 psf


(Icr+Iu)/2 = 252.4 in4/ft
Vertical Load Span (in)

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

2W PANELS

19

8'-0"

3W PANELS

GA

3WH-36 Composite Deck 2.4

GENERAL INFORMATION

81

TABLE OF CONTENTS

3.1 2WH-36
12"

12"

5"

5"

2-1/8"

2-1/8"

5"

5"
36"

36"

2WH-36 Profile

2WHS-36 Profile

36/4

36/4 Attachment Patterns


2W Series Embossment
Panel Properties

Gage

Weight

22
21
20
19
18
16

w
psf
1.57
1.78
1.89
2.25
2.51
3.14
Compression

Gage

Area

22
21
20
19
18
16

Ae
in2/ft
0.315
0.383
0.419
0.551
0.650
0.882

Base Metal
Thickness Yield Strength
t
in
0.029
0.033
0.035
0.042
0.047
0.059

Fy
ksi
50
50
50
50
50
50

Tensile
Strength

Area

Fu
ksi
65
65
65
65
65
65

Ag
in2/ft
0.448
0.509
0.540
0.646
0.722
0.902

Effective Section Modulus at Fy


Bending
Distance to
Section
N.A. from
Section
Modulus
Bottom
Modulus
Se+
yb
Sein3/ft
in
in3/ft
0.272
0.97
0.270
0.322
0.99
0.321
0.348
1.00
0.348
0.442
1.03
0.444
0.510
1.05
0.514
0.655
1.06
0.654

Gage
22
21
20
19
18
16

82

Condition

1"
End
316
Interior
528
End
403
Interior
675
End
450
Interior
755
End
633
Interior
1066
End
781
Interior
1319
End
1194
Interior
2027
Web Crippling Constraints

Ig
in4/ft
0.363
0.413
0.437
0.523
0.580
0.723

yb
in
1.06
1.06
1.06
1.06
1.06
1.06

Sg
in3/ft
0.345
0.575
0.414
0.493
0.548
0.679

Radius of
Gyration
r
in
0.902
0.901
0.901
0.899
0.898
0.895

Effective Moment of Inertia for Deflection


Distance to
N.A. from
Bottom
yb
in
1.16
1.14
1.13
1.10
1.09
1.07

Reactions at Supports (plf) Based on Web Crippling


Allowable (Rn/)
2"
4"
393
503
638
792
499
636
810
1001
556
707
903
1114
777
980
1266
1549
954
1199
1559
1898
1445
1800
2373
2862
h=2.16"

Gross Section Properties


Distance to
Moment of
N.A. from
Section
Inertia
Bottom
Modulus

Moment of
Inertia

Moment of
Inertia

Ie+
in4/ft
0.343
0.400
0.430
0.523
0.580
0.723

I ein4/ft
0.337
0.393
0.423
0.517
0.580
0.723

Bearing Length of Webs


6"
588
911
741
1148
822
1275
1137
1766
1387
2158
2072
3237

1"
483
786
616
1004
688
1123
968
1585
1195
1961
1827
3015
r=0.125"

Composite and Non-Composite Deck Catalog May 2014

Uniform Load Only


Id = (2Ie+Ig)/3
I+
in4/ft
0.350
0.404
0.432
0.523
0.580
0.723

Factored (Rn)
2"
4"
602
770
948
1178
764
973
1205
1489
851
1081
1344
1657
1188
1500
1883
2304
1460
1835
2318
2823
2211
2754
3530
4257
=64

Iin4/ft
0.346
0.400
0.428
0.519
0.580
0.723

6"
899
1355
1133
1708
1258
1897
1739
2627
2122
3211
3170
4815

www.ascsd.com

TABLE OF CONTENTS

12"

5"

2-1/8"
36/4

5"

GENERAL INFORMATION

2WHF-36 3.2

36/4 Attachment Patterns

36"

2WHF-36 Profile

Gage

Gage

Area
Ag
in2/ft
0.990
1.131
1.285
1.172
1.313
1.467
1.354
1.495
1.649

Effective Section Modulus at Fy


Bending
Distance to
N.A. from
Bottom
yb
in
0.51
0.46
0.41
0.63
0.58
0.53
0.74
0.68
0.63

Section
Modulus
Sein3/ft
0.365
0.428
0.448
0.442
0.564
0.590
0.522
0.663
0.730

Effective Moment of Inertia for Deflection


Distance to
N.A. from
Bottom
yb
in
1.16
1.02
0.86
1.21
1.09
0.96
1.24
1.14
1.02

Moment of
Inertia
Ie +
in4/ft
0.662
0.700
0.734
0.930
0.989
1.042
1.186
1.263
1.335

Moment of
Inertia
I ein4/ft
0.561
0.636
0.678
0.724
0.788
0.841
0.878
0.949
0.995

Uniform Load Only


Id = (2Ie+Ig)/3
I+
in4/ft
0.685
0.726
0.762
0.929
0.988
1.042
1.162
1.237
1.307

Iin4/ft
0.618
0.683
0.724
0.792
0.854
0.908
0.957
1.028
1.081

C PANELS

Section
Modulus
Se+
in3/ft
0.345
0.350
0.355
0.528
0.536
0.543
0.731
0.742
0.752

Radius of
Gyration
r
in
0.859
0.829
0.798
0.889
0.867
0.843
0.907
0.890
0.872

N PANELS

20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16

Area
Ae
in2/ft
0.559
0.638
0.756
0.753
0.832
0.951
0.957
1.037
1.157

Tensile
Strength
Fu
ksi
65
65
65
65
65
65
65
65
65

B PANELS

Compression

Base Metal
Thickness Yield Strength
t
Fy
in
ksi
0.035 / 0.036
50
0.035 / 0.047
50
0.035 / 0.059
50
0.047 / 0.036
50
0.047 / 0.047
50
0.047 / 0.059
50
0.059 / 0.036
50
0.059 / 0.047
50
0.059 / 0.059
50

2W PANELS

20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16

Weight
w
psf
3.63
4.10
4.62
4.28
4.76
5.28
4.95
5.43
5.95

Gross Section Properties


Distance to
Moment of
N.A. from
Section
Inertia
Bottom
Modulus
Ig
yb
Sg
in4/ft
in
in3/ft
0.731
0.62
0.463
0.777
0.66
0.470
0.818
0.50
0.477
0.927
0.70
0.614
0.987
0.64
0.624
1.041
0.59
0.633
1.113
0.76
0.764
1.185
0.70
0.776
1.253
0.65
0.787

3W PANELS

Panel Properties

D PANEL
ACUSTADEK

www.ascsd.com

Composite and Non-Composite Deck Catalog May 2014

83

TABLE OF CONTENTS

3.3 2WHF-36 Cellular Composite Deck


Normal Weight Concrete (145 pcf)
Maximum Unshored Spans

2WHF-36 Cellular Shoring Table


Total Slab Depth
(in)

Volume
cy/100sf

0.907

1.215

5 1/2
1 Hour
Fire Rating

1.370

6 1/2
2 Hour
Fire Rating

1.678

7 1/4
3 Hour
Fire Rating

1.910

Gage
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16

145 pcf Normal Weight Concrete


Maximum Unshored Span
Slab and Deck
psf
Single
Double
39.1
9' - 9"
10' - 10"
39.6
9' - 10"
11' - 8"
40.1
9' - 10"
11' - 11"
39.8
12' - 1"
11' - 10"
40.3
12' - 3"
13' - 4"
40.8
12' - 4"
13' - 7"
40.4
12' - 9"
12' - 10"
40.9
12' - 11"
14' - 5"
41.4
13' - 1"
15' - 1"
51.2
8' - 10"
9' - 11"
51.7
8' - 11"
10' - 8"
52.2
8' - 11"
10' - 11"
51.9
11' - 4"
10' - 10"
52.3
11' - 5"
12' - 3"
52.9
11' - 6"
12' - 6"
52.5
12' - 0"
11' - 9"
53.0
12' - 2"
13' - 2"
53.5
12' - 3"
13' - 10"
57.2
8' - 6"
9' - 6"
57.7
8' - 6"
10' - 4"
58.2
8' - 7"
10' - 6"
57.9
10' - 11"
10' - 5"
58.4
11' - 0"
11' - 9"
58.9
11' - 0"
12' - 0"
58.6
11' - 8"
11' - 4"
59.0
11' - 10"
12' - 8"
59.6
12' - 0"
13' - 3"
69.3
7' - 11"
8' - 11"
69.8
7' - 11"
9' - 7"
70.3
8' - 0"
9' - 9"
70.0
10' - 2"
9' - 9"
70.5
10' - 2"
11' - 0"
71.0
10' - 3"
11' - 2"
70.7
11' - 2"
10' - 7"
71.1
11' - 4"
11' - 10"
71.7
11' - 6"
12' - 5"
78.4
7' - 6"
8' - 6"
78.9
7' - 7"
9' - 2"
79.4
7' - 8"
9' - 4"
79.0
9' - 8"
9' - 4"
79.5
9' - 9"
10' - 6"
80.0
9' - 9"
10' - 8"
79.7
10' - 9"
10' - 1"
80.2
10' - 11"
11' - 4"
80.7
11' - 1"
11' - 10"

Triple
10' - 11"
10' - 11"
10' - 11"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
9' - 11"
10' - 0"
10' - 0"
12' - 3"
12' - 4"
12' - 4"
13' - 4"
13' - 4"
13' - 4"
9' - 7"
9' - 7"
9' - 8"
11' - 10"
11' - 10"
11' - 11"
13' - 0"
13' - 3"
13' - 4"
8' - 11"
9' - 0"
9' - 0"
11' - 0"
11' - 1"
11' - 1"
12' - 6"
12' - 8"
12' - 10"
8' - 6"
8' - 7"
8' - 7"
10' - 6"
10' - 7"
10' - 7"
12' - 1"
12' - 4"
12' - 5"

Shaded area the span is governed by maximum deck panel length of 40 feet; 20 feet for double span, 13 feet 4 inches for triple span.

84

Composite and Non-Composite Deck Catalog May 2014

www.ascsd.com

TABLE OF CONTENTS

2WHF-36 Cellular Composite Deck 3.3


Light Weight Concrete (110 pcf)
Maximum Unshored Spans

Volume
cy/100sf

0.907

1 Hour
Fire Rating

1.215

2 Hour
Fire Rating

1.292

3 Hour
Fire Rating

1.582

D PANEL

6 3/16

C PANELS

5 1/4

N PANELS

1.061

Triple
11' - 10"
11' - 11"
11' - 11"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
11' - 4"
11' - 5"
11' - 5"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
10' - 11"
11' - 0"
11' - 0"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
10' - 9"
10' - 9"
10' - 10"
13' - 2"
13' - 3"
13' - 3"
13' - 4"
13' - 4"
13' - 4"
10' - 1"
10' - 1"
10' - 2"
12' - 5"
12' - 5"
12' - 6"
13' - 4"
13' - 4"
13' - 4"

B PANELS

4 1/2

ACUSTADEK

Gage
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16

110 pcf Light Weight Concrete


Maximum Unshored Span
Slab and Deck
psf
Single
Double
30.6
10' - 9"
11' - 10"
31.0
10' - 10"
12' - 9"
31.5
10' - 10"
13' - 0"
31.2
12' - 11"
12' - 11"
31.7
13' - 0"
14' - 6"
32.2
13' - 2"
14' - 10"
31.9
13' - 7"
14' - 0"
32.4
13' - 9"
15' - 8"
32.9
13' - 10"
16' - 5"
35.1
10' - 3"
11' - 4"
35.6
10' - 3"
12' - 2"
36.1
10' - 4"
12' - 5"
35.8
12' - 6"
12' - 4"
36.3
12' - 8"
13' - 11"
36.8
12' - 9"
14' - 2"
36.5
13' - 2"
13' - 5"
36.9
13' - 4"
15' - 0"
37.5
13' - 5"
15' - 8"
39.7
9' - 9"
10' - 10"
40.2
9' - 10"
11' - 9"
40.7
9' - 11"
11' - 11"
40.4
12' - 1"
11' - 11"
40.9
12' - 3"
13' - 5"
41.4
12' - 5"
13' - 8"
41.0
12' - 9"
12' - 10"
41.5
12' - 11"
14' - 5"
42.0
13' - 1"
15' - 1"
42.0
9' - 7"
10' - 8"
42.5
9' - 8"
11' - 6"
43.0
9' - 8"
11' - 9"
42.7
12' - 0"
11' - 8"
43.1
12' - 1"
13' - 2"
43.7
12' - 3"
13' - 5"
43.3
12' - 7"
12' - 8"
43.8
12' - 9"
14' - 2"
44.3
12' - 11"
14' - 10"
50.6
8' - 11"
10' - 0"
51.1
9' - 0"
10' - 10"
51.6
9' - 0"
11' - 0"
51.3
11' - 5"
11' - 0"
51.7
11' - 7"
12' - 4"
52.3
11' - 8"
12' - 7"
51.9
12' - 1"
11' - 10"
52.4
12' - 3"
13' - 4"
52.9
12' - 4"
13' - 11"

2W PANELS

Total Slab Depth


(in)

3W PANELS

2WHF-36 Cellular Shoring Table

Shaded area the span is governed by maximum deck panel length of 40 feet; 20 feet for double span, 13 feet 4 inches for triple span.

www.ascsd.com

GENERAL INFORMATION

Composite and Non-Composite Deck Catalog May 2014

85

TABLE OF CONTENTS

3.3 2WH-36 Composite Deck


4" Total Slab Depth
Normal Weight Concrete (145 pcf)

Gage
22
21
20
GA

22

Concrete Volume 0.907yd3/100ft2

Single
8' - 5"
9' - 5"
9' - 9"

Maximum Unshored Span (in)


Triple
Gage
9' - 9"
19
10' - 7"
18
11' - 0"
16

Double
9' - 4"
10' - 3"
10' - 8"

Vertical Load Span (in)

6'-0"

6'-6"

ASD, W/
LRFD, W
L/360

391
626
-

329
527
-

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

7'-0"

ASD, W/
LRFD, W
L/360
21

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

36/4
2190
2024
2012
2000

Icr = 22.9 in4/ft


Iu = 58.4 in4/ft
7'-0"

7'-6"

8'-0"

8'-6"

97
154
-

86
137
-

77
123
-

68
109
-

61
98
-

Attachment Pattern
2180 2162 2145
2024 2013 2004
2012 2002 1992
2000 1991 1982

2130
1995
1984
1974

2116
1987
1977
1967

2103
1979
1970
1961

2100
1981
1971
1963

2089
1974
1965
1957

Mno/= 23.7 kip-in/ft


Mno= 36.3 kip-in/ft

442
707
-

6'-0"

6'-6"

ASD, W/
LRFD, W
L/360

466
746
-

393
629
-

36/4
2244
2054
2040
2027

Icr = 25.2 in4/ft


Iu = 59.5 in4/ft
7'-0"

7'-6"

8'-0"

8'-6"

9'-0"

36/4
2272
2070
2054
2041

Icr = 26.3 in4/ft


Iu = 60.0 in4/ft

Composite and Non-Composite Deck Catalog May 2014

Vn/ = 3.02 kip/ft


Vn = 4.52 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"


125
200
-

111
178
-

100
159
-

89
143
-

80
128
-

72
115
-

Attachment Pattern
2235 2214 2194
2055 2043 2032
2041 2030 2019
2029 2018 2008

2177
2021
2009
1999

2161
2012
2001
1991

2146
2003
1992
1983

2143
2006
1996
1986

2130
1998
1988
1979

Mno/= 26.6 kip-in/ft


Mno= 40.6 kip-in/ft

Vn/ = 3.02 kip/ft


Vn = 4.52 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

ASD & LRFD - Superimposed Load, W (psf)


335 288 250 218 191 169 150
536 461 399 349 306 270 239
-

LRFD - Diaphragm Shear, Sn (plf / ft)


2481 2452 2406 2366 2331 2300
2178 2172 2146 2123 2103 2085
2155 2150 2126 2104 2086 2069
2135 2132 2109 2088 2071 2055

Triple
12' - 4"
12' - 8"
13' - 4"

109
174
-

ASD & LRFD - Superimposed Load, W (psf)


372 317 273 236 206 181 159 141
596 507 436 378 329 289 255 225
-

LRFD - Diaphragm Shear, Sn (plf / ft)


2441 2413 2369 2332 2299 2270
2157 2150 2125 2104 2085 2069
2135 2130 2106 2087 2069 2054
2115 2112 2090 2071 2055 2040

9'-0"

Double
12' - 0"
12' - 11"
14' - 2"

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

6'-6"

Concrete + Deck = 38.1 psf


(Icr+Iu)/2 = 43.14 in4/ft

86

9'-0"

6'-0"

Vertical Load Span (in)

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

8'-6"

LRFD - Diaphragm Shear, Sn (plf / ft)


2362 2335 2298 2265 2237 2212
2115 2107 2086 2067 2051 2037
2095 2089 2069 2052 2037 2023
2077 2072 2054 2037 2023 2011

Concrete + Deck = 38.0 psf


(Icr+Iu)/2 = 42.35 in4/ft

20

8'-0"

ASD & LRFD - Superimposed Load, W (psf)


280 240 208 181 158 139 123
448 384 332 289 253 223 196
-

Concrete + Deck = 37.8 psf


(Icr+Iu)/2 = 40.66 in4/ft
Vertical Load Span (in)

7'-6"

Single
10' - 4"
10' - 8"
11' - 5"

133
213
-

119
190
-

106
170
-

95
152
-

85
137
-

77
123
-

Attachment Pattern
2263 2240 2219
2071 2058 2046
2057 2044 2033
2044 2032 2021

2201
2035
2022
2012

2183
2025
2013
2003

2168
2016
2004
1994

2165
2019
2008
1999

2151
2011
2000
1991

Mno/= 27.9 kip-in/ft


Mno= 42.7 kip-in/ft

Vn/ = 3.02 kip/ft


Vn = 4.52 kip/ft

www.ascsd.com

TABLE OF CONTENTS

2WH-36 Composite Deck 3.3


4" Total Slab Depth
Normal Weight Concrete (145 pcf)

Concrete Volume 0.907yd3/100ft2

Vertical Load Span (in)


ASD, W/
LRFD, W
L/360
Arc Spot Weld 1/2" Effective Dia
PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

6'-6"

549
879
-

ASD & LRFD - Superimposed Load, W (psf)


464 396 341 296 259 228 202 179
742 633 546 474 415 365 323 287
-

7'-0"

18

16

129
206
-

116
185
-

104
167
-

94
151
-

Attachment Pattern
2365 2337 2311
2131 2114 2099
2113 2098 2083
2100 2085 2071

2288
2086
2070
2059

2266
2073
2059
2048

2247
2062
2048
2037

2246
2068
2055
2045

2229
2058
2045
2035

Mno/= 32.6 kip-in/ft


Mno= 50.0 kip-in/ft

6'-0"

6'-6"

603
966
-

ASD & LRFD - Superimposed Load, W (psf)


510 436 376 327 286 252 223 199
816 697 601 523 458 403 357 318
-

7'-0"

7'-6"

8'-0"

8'-6"

LRFD - Diaphragm Shear, Sn (plf / ft)


2731 2700 2635 2579 2530 2486
2311 2312 2275 2243 2215 2190
2280 2284 2249 2218 2192 2168
2259 2264 2230 2201 2176 2153

6'-0"

6'-6"

741 627
1185 1003
-

9'-0"

36/4
2448
2168
2147
2133

7'-0"

7'-6"

8'-0"

8'-6"

9'-0"

177
284
-

159
255
-

143
229
-

129
207
129

114
187
114

101
169
101

Attachment Pattern
2441 2409 2380
2176 2157 2140
2157 2139 2122
2143 2126 2110

2353
2124
2107
2095

2329
2109
2093
2082

2306
2096
2081
2070

2307
2105
2091
2080

2287
2093
2079
2069

Mno/= 35.7 kip-in/ft


Mno= 54.6 kip-in/ft

36/4
2637
2276
2237
2236

Vn/ = 3.02 kip/ft


Vn = 4.52 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

ASD & LRFD - Superimposed Load, W (psf)


536 463 404 354 313 278 242
858 741 646 567 500 444 396
242

LRFD - Diaphragm Shear, Sn (plf / ft)


2996 2967 2882 2809 2744 2688
2453 2466 2417 2375 2337 2305
2396 2413 2368 2329 2294 2264
2394 2412 2366 2327 2293 2263

Vn/ = 3.02 kip/ft


Vn = 4.52 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

Icr = 32.1 in4/ft


Iu = 63.0 in4/ft

Concrete + Deck = 39.3 psf


(Icr+Iu)/2 = 51.77 in4/ft

209
355
209

182
319
182

159
288
159

140
261
140

124
237
124

110
215
110

Attachment Pattern
2636 2594 2555
2294 2268 2245
2257 2234 2212
2256 2233 2211

2520
2224
2192
2192

2488
2205
2175
2174

2458
2187
2158
2157

2464
2204
2177
2176

2438
2188
2161
2161

Mno/= 43.5 kip-in/ft


Mno= 66.5 kip-in/ft

Icr = 37.6 in4/ft


Iu = 65.9 in4/ft

Vn/ = 3.02 kip/ft


Vn = 4.52 kip/ft

LRFD - Diaphragm Shear, Sn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width

3/4" Welded Shear Studs


12 in o.c.
24 in o.c.
36 in o.c.

www.ascsd.com

6x6 W1.4xW1.4

As = 0.028 in2/ft
3060
3060
3060

6x6 W2.9xW2.9

As = 0.058 in2/ft
4410
4410
4410

6x6 W4.0xW4.0

As = 0.080 in2/ft
5400
5400
5170

4x4 W4xW4

As = 0.120 in2/ft
7200
7200
5170

4x4 W6xW6

As = 0.180 in2/ft
9900
7750
5170

Composite and Non-Composite Deck Catalog May 2014

ACUSTADEK

All Gages

143
229
-

D PANEL

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

160
256
-

C PANELS

ASD, W/
LRFD, W
L/360

36/4
2373
2126
2108
2093

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

Icr = 29.9 in4/ft


Iu = 61.8 in4/ft

Concrete + Deck = 38.7 psf


(Icr+Iu)/2 = 47.57 in4/ft
Vertical Load Span (in)

9'-0"

N PANELS

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

8'-6"

B PANELS

ASD, W/
LRFD, W
L/360

8'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


2625 2594 2537 2488 2445 2407
2255 2252 2220 2191 2167 2145
2227 2227 2196 2169 2146 2126
2206 2207 2178 2152 2130 2111

Concrete + Deck = 38.5 psf


(Icr+Iu)/2 = 45.85 in4/ft
Vertical Load Span (in)

7'-6"

2W PANELS

19

6'-0"

3W PANELS

GA

GENERAL INFORMATION

87

TABLE OF CONTENTS

3.3 2WH-36 Composite Deck

412" Total Slab Depth


Normal Weight Concrete (145 pcf)

Gage
22
21
20
GA

22

Concrete Volume 1.061yd3/100ft2

Single
8' - 0"
8' - 11"
9' - 3"

Maximum Unshored Span (in)


Triple
Gage
9' - 3"
19
10' - 1"
18
10' - 6"
16

Double
8' - 11"
9' - 9"
10' - 2"

Vertical Load Span (in)

6'-0"

6'-6"

ASD, W/
LRFD, W
L/360

473
757
-

398
637
-

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

7'-0"

ASD, W/
LRFD, W
L/360
21

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

36/4
2680
2515
2502
2490

Icr = 31.4 in4/ft


Iu = 82.4 in4/ft
7'-0"

7'-6"

8'-0"

8'-6"

118
188
-

105
168
-

93
150
-

84
134
-

75
120
-

Attachment Pattern
2671 2652 2635
2514 2504 2494
2502 2492 2483
2491 2481 2473

2620
2485
2475
2465

2606
2477
2467
2458

2594
2470
2460
2451

2590
2471
2462
2453

2579
2465
2456
2447

Mno/= 28.6 kip-in/ft


Mno= 43.7 kip-in/ft

534
855
-

6'-0"

6'-6"

ASD, W/
LRFD, W
L/360

563
902
-

475
760
-

36/4
2735
2545
2530
2517

Icr = 34.5 in4/ft


Iu = 83.8 in4/ft
7'-0"

7'-6"

8'-0"

8'-6"

9'-0"

36/4
2763
2560
2545
2532

Icr = 36.0 in4/ft


Iu = 84.5 in4/ft

Composite and Non-Composite Deck Catalog May 2014

Vn/ = 3.51 kip/ft


Vn = 5.04 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"


152
243
-

136
217
-

121
194
-

109
174
-

98
156
-

88
140
-

Attachment Pattern
2725 2704 2685
2546 2533 2522
2532 2520 2509
2520 2508 2498

2667
2512
2500
2489

2651
2502
2491
2481

2636
2494
2483
2473

2633
2496
2486
2477

2620
2489
2479
2470

Mno/= 32.0 kip-in/ft


Mno= 49.0 kip-in/ft

Vn/ = 3.51 kip/ft


Vn = 5.26 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

ASD & LRFD - Superimposed Load, W (psf)


405 349 302 264 232 205 182
648 558 484 423 371 328 291
-

LRFD - Diaphragm Shear, Sn (plf / ft)


2972 2942 2896 2856 2821 2790
2668 2662 2636 2613 2593 2576
2645 2641 2616 2595 2576 2560
2625 2623 2599 2579 2561 2546

Triple
11' - 10"
12' - 3"
12' - 11"

132
212
-

ASD & LRFD - Superimposed Load, W (psf)


450 384 330 286 250 219 193 171
720 614 528 458 399 350 309 274
-

LRFD - Diaphragm Shear, Sn (plf / ft)


2932 2903 2860 2822 2789 2760
2647 2640 2616 2594 2576 2559
2625 2620 2597 2577 2559 2544
2606 2602 2580 2562 2545 2530

9'-0"

Double
11' - 5"
12' - 3"
13' - 9"

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

6'-6"

Concrete + Deck = 44.3 psf


(Icr+Iu)/2 = 60.2 in4/ft

88

9'-0"

6'-0"

Vertical Load Span (in)

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

8'-6"

LRFD - Diaphragm Shear, Sn (plf / ft)


2853 2826 2788 2756 2727 2702
2605 2597 2576 2558 2542 2527
2586 2579 2559 2542 2527 2514
2568 2563 2544 2528 2514 2501

Concrete + Deck = 44.2 psf


(Icr+Iu)/2 = 59.2 in4/ft

20

8'-0"

ASD & LRFD - Superimposed Load, W (psf)


339 291 252 219 192 169 149
542 465 402 350 307 270 239
-

Concrete + Deck = 43.9 psf


(Icr+Iu)/2 = 56.9 in4/ft
Vertical Load Span (in)

7'-6"

Single
9' - 10"
10' - 2"
10' - 11"

162
259
-

144
231
-

129
207
-

116
186
-

104
167
-

94
150
-

Attachment Pattern
2754 2731 2710
2562 2548 2536
2547 2535 2523
2535 2523 2512

2691
2525
2513
2502

2674
2515
2503
2493

2658
2506
2495
2485

2655
2510
2498
2489

2641
2501
2491
2482

Mno/= 33.7 kip-in/ft


Mno= 51.6 kip-in/ft

Vn/ = 3.51 kip/ft


Vn = 5.26 kip/ft

www.ascsd.com

TABLE OF CONTENTS

2WH-36 Composite Deck 3.3


412" Total Slab Depth
Normal Weight Concrete (145 pcf)

Concrete Volume 1.061yd3/100ft2

Vertical Load Span (in)


ASD, W/
LRFD, W
L/360
Arc Spot Weld 1/2" Effective Dia
PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

6'-6"

665
1064
-

ASD & LRFD - Superimposed Load, W (psf)


561 480 413 359 314 277 245 218
898 767 661 575 503 443 392 349
-

7'-0"

18

16

157
251
-

141
226
-

127
204
-

115
184
-

Attachment Pattern
2855 2827 2801
2621 2605 2590
2604 2588 2574
2591 2575 2562

2778
2576
2561
2549

2757
2563
2549
2538

2737
2552
2538
2528

2736
2558
2545
2535

2719
2548
2535
2525

Mno/= 39.4 kip-in/ft


Mno= 60.3 kip-in/ft

6'-0"

6'-6"

730
1169
-

ASD & LRFD - Superimposed Load, W (psf)


617 528 455 396 347 306 271 241
988 844 729 634 555 490 434 386
-

7'-0"

7'-6"

8'-0"

8'-6"

LRFD - Diaphragm Shear, Sn (plf / ft)


3222 3190 3125 3069 3020 2977
2802 2803 2765 2733 2705 2680
2771 2774 2739 2709 2682 2659
2749 2754 2721 2692 2666 2643

6'-0"

6'-6"

9'-0"

36/4
2938
2658
2638
2623

7'-0"

7'-6"

8'-0"

8'-6"

9'-0"

216
345
-

194
310
-

174
279
-

157
252
-

142
228
-

129
207
-

Attachment Pattern
2932 2899 2870
2667 2647 2630
2647 2629 2612
2633 2616 2600

2843
2614
2598
2586

2819
2600
2584
2573

2797
2587
2571
2561

2797
2596
2581
2571

2778
2584
2570
2560

Mno/= 43.1 kip-in/ft


Mno= 66.0 kip-in/ft

36/4
3128
2766
2728
2727

Vn/ = 3.51 kip/ft


Vn = 5.26 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

ASD & LRFD - Superimposed Load, W (psf)


898 760 650 562 490 430 380 338 301
1436 1216 1041 900 784 688 608 540 482
LRFD - Diaphragm Shear, Sn (plf / ft)
3486 3457 3372 3299 3235 3178
2944 2956 2907 2865 2828 2795
2886 2903 2858 2819 2785 2755
2885 2902 2857 2818 2784 2754

Vn/ = 3.51 kip/ft


Vn = 5.26 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

Icr = 44.1 in4/ft


Iu = 88.4 in4/ft

Concrete + Deck = 45.5 psf


(Icr+Iu)/2 = 72 in4/ft

270
432
-

243
389
-

220
351
-

195
318
195

172
289
172

153
263
153

Attachment Pattern
3127 3084 3045
2784 2758 2735
2748 2724 2702
2747 2723 2702

3010
2714
2683
2682

2978
2695
2665
2664

2949
2677
2649
2648

2955
2694
2667
2666

2929
2678
2652
2651

Mno/= 52.6 kip-in/ft


Mno= 80.5 kip-in/ft

Icr = 51.6 in4/ft


Iu = 92.4 in4/ft

Vn/ = 3.51 kip/ft


Vn = 5.26 kip/ft

LRFD - Diaphragm Shear, Sn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width

3/4" Welded Shear Studs


12 in o.c.
24 in o.c.
36 in o.c.

www.ascsd.com

6x6 W1.4xW1.4

As = 0.028 in2/ft
3560
3560
3560

6x6 W2.9xW2.9

As = 0.058 in2/ft
4910
4910
4910

6x6 W4.0xW4.0

As = 0.080 in2/ft
5900
5900
5170

4x4 W4xW4

As = 0.120 in2/ft
7700
7700
5170

4x4 W6xW6

As = 0.180 in2/ft
10400
7750
5170

Composite and Non-Composite Deck Catalog May 2014

ACUSTADEK

All Gages

174
279
-

D PANEL

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

195
311
-

C PANELS

ASD, W/
LRFD, W
L/360

36/4
2863
2616
2598
2584

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

Icr = 40.9 in4/ft


Iu = 86.9 in4/ft

Concrete + Deck = 44.9 psf


(Icr+Iu)/2 = 66.3 in4/ft
Vertical Load Span (in)

9'-0"

N PANELS

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

8'-6"

B PANELS

ASD, W/
LRFD, W
L/360

8'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


3116 3085 3028 2978 2935 2897
2745 2742 2710 2682 2657 2636
2717 2717 2686 2660 2637 2616
2696 2697 2668 2643 2621 2601

Concrete + Deck = 44.6 psf


(Icr+Iu)/2 = 63.9 in4/ft
Vertical Load Span (in)

7'-6"

2W PANELS

19

6'-0"

3W PANELS

GA

GENERAL INFORMATION

89

TABLE OF CONTENTS

3.3 2WH-36 Composite Deck


5" Total Slab Depth
Normal Weight Concrete (145 pcf)

Gage
22
21
20
GA

22

Concrete Volume 1.215yd3/100ft2

Single
7' - 8"
8' - 6"
8' - 11"

Maximum Unshored Span (in)


Triple
Gage
8' - 11"
19
9' - 8"
18
10' - 1"
16

Double
8' - 7"
9' - 4"
9' - 9"

Vertical Load Span (in)

6'-0"

6'-6"

ASD, W/
LRFD, W
L/360

558
893
-

470
752
-

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

7'-0"

ASD, W/
LRFD, W
L/360
21

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

36/4
3170
3005
2992
2980

Icr = 41.4 in4/ft


Iu = 112.4 in4/ft
7'-0"

7'-6"

8'-0"

8'-6"

140
224
-

125
199
-

111
178
-

100
160
-

89
143
-

Attachment Pattern
3161 3143 3126
3005 2994 2984
2993 2982 2973
2981 2972 2963

3111
2976
2965
2955

3097
2968
2958
2948

3084
2960
2951
2942

3080
2962
2952
2944

3069
2955
2946
2938

Mno/= 33.7 kip-in/ft


Mno= 51.5 kip-in/ft

631
1010
-

6'-0"

6'-6"

ASD, W/
LRFD, W
L/360

666
1066
-

562
899
-

36/4
3225
3035
3021
3008

Icr = 45.6 in4/ft


Iu = 114.2 in4/ft
7'-0"

7'-6"

8'-0"

8'-6"

9'-0"

36/4
3253
3051
3035
3022

Icr = 47.6 in4/ft


Iu = 115.1 in4/ft

Composite and Non-Composite Deck Catalog May 2014

Vn/ = 3.78 kip/ft


Vn = 5.43 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"


181
289
-

161
258
-

144
231
-

129
207
-

116
186
-

105
168
-

Attachment Pattern
3216 3194 3175
3036 3024 3012
3022 3010 3000
3010 2999 2989

3157
3002
2990
2980

3141
2993
2981
2971

3127
2984
2973
2964

3124
2987
2976
2967

3111
2979
2969
2960

Mno/= 37.8 kip-in/ft


Mno= 57.8 kip-in/ft

Vn/ = 4.03 kip/ft


Vn = 6.04 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

ASD & LRFD - Superimposed Load, W (psf)


479 413 358 313 275 243 216
767 660 573 501 440 389 345
-

LRFD - Diaphragm Shear, Sn (plf / ft)


3462 3433 3387 3347 3311 3281
3159 3153 3126 3104 3084 3066
3136 3131 3107 3085 3066 3050
3116 3113 3090 3069 3052 3036

Triple
11' - 4"
11' - 11"
12' - 6"

157
251
-

ASD & LRFD - Superimposed Load, W (psf)


532 454 390 338 295 259 229 203
851 726 624 542 473 415 366 325
-

LRFD - Diaphragm Shear, Sn (plf / ft)


3422 3393 3350 3313 3280 3251
3137 3131 3106 3085 3066 3050
3116 3110 3087 3067 3050 3034
3096 3093 3071 3052 3035 3021

9'-0"

Double
10' - 11"
11' - 9"
13' - 3"

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

6'-6"

Concrete + Deck = 50.4 psf


(Icr+Iu)/2 = 81.36 in4/ft

90

9'-0"

6'-0"

Vertical Load Span (in)

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

8'-6"

LRFD - Diaphragm Shear, Sn (plf / ft)


3343 3316 3279 3246 3218 3193
3095 3088 3066 3048 3032 3018
3076 3070 3050 3033 3018 3004
3058 3053 3034 3018 3004 2992

Concrete + Deck = 50.3 psf


(Icr+Iu)/2 = 79.92 in4/ft

20

8'-0"

ASD & LRFD - Superimposed Load, W (psf)


400 344 298 259 227 200 177
640 550 476 415 364 320 283
-

Concrete + Deck = 50.1 psf


(Icr+Iu)/2 = 76.88 in4/ft
Vertical Load Span (in)

7'-6"

Single
9' - 6"
9' - 10"
10' - 6"

192
307
-

172
275
-

154
246
-

138
221
-

124
199
-

112
179
-

Attachment Pattern
3244 3221 3200
3052 3039 3027
3038 3025 3014
3025 3013 3002

3181
3016
3003
2992

3164
3006
2994
2983

3148
2997
2985
2975

3146
3000
2989
2979

3132
2992
2981
2972

Mno/= 39.7 kip-in/ft


Mno= 60.8 kip-in/ft

Vn/ = 4.03 kip/ft


Vn = 6.04 kip/ft

www.ascsd.com

TABLE OF CONTENTS

2WH-36 Composite Deck 3.3


5" Total Slab Depth
Normal Weight Concrete (145 pcf)

Concrete Volume 1.215yd3/100ft2

Vertical Load Span (in)


ASD, W/
LRFD, W
L/360
Arc Spot Weld 1/2" Effective Dia
PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

6'-6"

7'-0"

18

6'-0"

6'-6"

16

186
298
-

168
269
-

152
243
-

138
220
-

Attachment Pattern
3346 3318 3292
3112 3095 3080
3094 3079 3064
3081 3066 3052

3269
3066
3051
3040

3247
3054
3039
3028

3228
3042
3029
3018

3227
3049
3036
3025

3209
3038
3026
3016

Mno/= 46.6 kip-in/ft


Mno= 71.3 kip-in/ft

7'-0"

7'-6"

8'-0"

8'-6"

9'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


3712 3681 3616 3560 3511 3467
3292 3293 3256 3224 3196 3171
3261 3265 3230 3199 3173 3149
3240 3245 3211 3182 3156 3134

6'-0"

6'-6"

36/4
3429
3149
3128
3114

257
411
-

230
369
-

208
332
-

187
300
-

170
272
-

154
247
-

Attachment Pattern
3422 3390 3360
3157 3138 3120
3138 3119 3103
3124 3106 3091

3334
3105
3088
3076

3309
3090
3074
3063

3287
3077
3062
3051

3288
3086
3071
3061

3268
3074
3060
3050

Mno/= 51.0 kip-in/ft


Mno= 78.0 kip-in/ft

Icr = 58.4 in4/ft


Iu = 120.3 in4/ft
7'-0"

7'-6"

8'-0"

8'-6"

9'-0"

36/4
3618
3257
3218
3217

Vn/ = 4.03 kip/ft


Vn = 6.04 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

ASD & LRFD - Superimposed Load, W (psf)


1065 901 772 667 582 511 452 401 358
1703 1442 1235 1068 931 818 723 642 573
LRFD - Diaphragm Shear, Sn (plf / ft)
3977 3948 3863 3789 3725 3669
3434 3447 3398 3355 3318 3286
3377 3394 3349 3309 3275 3245
3375 3392 3347 3308 3274 3244

Vn/ = 4.03 kip/ft


Vn = 6.04 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

ASD & LRFD - Superimposed Load, W (psf)


865 731 625 540 470 412 363 322 287
1383 1170 1000 863 751 659 581 515 459
-

Concrete + Deck = 51.7 psf


(Icr+Iu)/2 = 96.95 in4/ft

321
514
-

289
463
-

262
419
-

237
379
-

215
345
-

196
314
-

Attachment Pattern
3617 3574 3536
3274 3249 3226
3238 3214 3193
3237 3214 3192

3501
3205
3173
3173

3468
3185
3155
3155

3439
3168
3139
3138

3445
3185
3157
3157

3419
3169
3142
3142

Mno/= 62.3 kip-in/ft


Mno= 95.3 kip-in/ft

Icr = 68.5 in4/ft


Iu = 125.4 in4/ft

Vn/ = 4.03 kip/ft


Vn = 6.04 kip/ft

LRFD - Diaphragm Shear, Sn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width

3/4" Welded Shear Studs


12 in o.c.
24 in o.c.
36 in o.c.

www.ascsd.com

6x6 W1.4xW1.4

As = 0.028 in2/ft
4050
4050
4050

6x6 W2.9xW2.9

As = 0.058 in2/ft
5400
5400
5170

6x6 W4.0xW4.0

As = 0.080 in2/ft
6390
6390
5170

4x4 W4xW4

As = 0.120 in2/ft
8190
7750
5170

4x4 W6xW6

As = 0.180 in2/ft
10890
7750
5170

Composite and Non-Composite Deck Catalog May 2014

ACUSTADEK

All Gages

207
332
-

D PANEL

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

36/4
3354
3107
3088
3074

231
370
-

C PANELS

ASD, W/
LRFD, W
L/360

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

Icr = 54.2 in4/ft


Iu = 118.2 in4/ft

Concrete + Deck = 51.0 psf


(Icr+Iu)/2 = 89.32 in4/ft
Vertical Load Span (in)

9'-0"

N PANELS

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

8'-6"

B PANELS

ASD, W/
LRFD, W
L/360

8'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


3606 3575 3518 3469 3426 3388
3235 3233 3200 3172 3148 3126
3208 3207 3177 3150 3127 3107
3187 3188 3159 3133 3111 3092

Concrete + Deck = 50.8 psf


(Icr+Iu)/2 = 86.24 in4/ft
Vertical Load Span (in)

7'-6"

ASD & LRFD - Superimposed Load, W (psf)


787 665 568 490 426 373 328 291 259
1259 1063 909 784 681 597 526 465 414
-

2W PANELS

19

6'-0"

3W PANELS

GA

GENERAL INFORMATION

91

TABLE OF CONTENTS

3.3 2WH-36 Composite Deck

5 12" Total Slab Depth


Normal Weight Concrete (145 pcf)

Gage
22
21
20
GA

22

Concrete Volume 1.370yd3/100ft2


1 Hour Fire Rating

Single
7' - 4"
8' - 2"
8' - 7"

Maximum Unshored Span (in)


Triple
Gage
8' - 6"
19
9' - 3"
18
9' - 8"
16

Double
8' - 3"
9' - 0"
9' - 4"

Vertical Load Span (in)

6'-0"

6'-6"

ASD, W/
LRFD, W
L/360

647
1035
-

545
872
-

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

7'-0"

ASD, W/
LRFD, W
L/360
21

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

ASD, W/
LRFD, W
L/360
20

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

9'-0"

36/4
3661
3496
3483
3471

Icr = 53.1 in4/ft


Iu = 149.2 in4/ft
7'-0"

7'-6"

8'-0"

8'-6"

163
261
-

145
233
-

130
208
-

117
186
-

105
167
-

Attachment Pattern
3652 3633 3616
3495 3484 3475
3483 3473 3464
3472 3462 3454

3601
3466
3456
3446

3587
3458
3448
3439

3575
3451
3441
3432

3571
3452
3443
3434

3560
3445
3437
3428

Mno/= 38.9 kip-in/ft


Mno= 59.5 kip-in/ft

731
1170
-

ASD & LRFD - Superimposed Load, W (psf)


617 526 453 393 343 302 266 236
987 842 725 629 549 482 426 378
-

6'-0"

6'-6"

772 652
1236 1043
-

36/4
3716
3526
3511
3498

Icr = 58.6 in4/ft


Iu = 151.5 in4/ft
7'-0"

7'-6"

8'-0"

8'-6"

9'-0"

36/4
3743
3541
3526
3513

Icr = 61.2 in4/ft


Iu = 152.6 in4/ft

Composite and Non-Composite Deck Catalog May 2014

Vn/ = 4.06 kip/ft


Vn = 5.84 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"


210
337
-

188
301
-

168
269
-

151
242
-

136
217
-

122
196
-

Attachment Pattern
3706 3685 3666
3526 3514 3503
3513 3501 3490
3500 3489 3479

3648
3493
3481
3470

3632
3483
3472
3462

3617
3475
3464
3454

3614
3477
3467
3458

3601
3470
3460
3451

Mno/= 43.7 kip-in/ft


Mno= 66.9 kip-in/ft

Vn/ = 4.57 kip/ft


Vn = 6.55 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

ASD & LRFD - Superimposed Load, W (psf)


556 479 416 364 320 283 251
890 766 665 582 511 452 401
-

LRFD - Diaphragm Shear, Sn (plf / ft)


3953 3923 3877 3837 3802 3771
3649 3643 3617 3594 3574 3557
3626 3622 3597 3576 3557 3540
3606 3603 3580 3560 3542 3526

Triple
10' - 11"
11' - 7"
12' - 2"

183
292
-

6'-6"

LRFD - Diaphragm Shear, Sn (plf / ft)


3913 3884 3841 3803 3770 3741
3628 3621 3597 3575 3557 3540
3606 3601 3578 3558 3540 3525
3587 3583 3561 3542 3526 3511

9'-0"

Double
10' - 6"
11' - 4"
12' - 8"

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

6'-0"

Concrete + Deck = 56.6 psf


(Icr+Iu)/2 = 106.9 in4/ft

92

8'-6"

LRFD - Diaphragm Shear, Sn (plf / ft)


3834 3807 3769 3737 3708 3683
3586 3578 3557 3539 3522 3508
3567 3560 3540 3523 3508 3495
3549 3544 3525 3509 3495 3482

Concrete + Deck = 56.5 psf


(Icr+Iu)/2 = 105 in4/ft
Vertical Load Span (in)

8'-0"

ASD & LRFD - Superimposed Load, W (psf)


464 399 345 301 264 233 206
742 638 553 482 422 372 329
-

Concrete + Deck = 56.3 psf


(Icr+Iu)/2 = 101.1 in4/ft
Vertical Load Span (in)

7'-6"

Single
9' - 2"
9' - 5"
10' - 2"

224
358
-

200
320
-

179
287
-

161
258
-

145
232
-

131
210
-

Attachment Pattern
3734 3711 3691
3543 3529 3517
3528 3515 3504
3516 3504 3493

3672
3506
3494
3483

3655
3496
3484
3474

3639
3487
3476
3466

3636
3490
3479
3470

3622
3482
3472
3462

Mno/= 46.0 kip-in/ft


Mno= 70.4 kip-in/ft

Vn/ = 4.57 kip/ft


Vn = 6.86 kip/ft

www.ascsd.com

TABLE OF CONTENTS

2WH-36 Composite Deck 3.3


5 12" Total Slab Depth
Normal Weight Concrete (145 pcf)

Concrete Volume 1.370yd3/100ft2


1 Hour Fire Rating

Vertical Load Span (in)


ASD, W/
LRFD, W
L/360
Arc Spot Weld 1/2" Effective Dia
PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

6'-6"

7'-0"

18

6'-0"

6'-6"

16

218
348
-

196
314
-

178
284
-

161
257
-

Attachment Pattern
3836 3808 3782
3602 3586 3570
3585 3569 3555
3571 3556 3543

3759
3557
3542
3530

3738
3544
3530
3519

3718
3533
3519
3508

3717
3539
3526
3516

3700
3529
3516
3506

Mno/= 54.0 kip-in/ft


Mno= 82.6 kip-in/ft

7'-0"

7'-6"

8'-0"

8'-6"

9'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


4202 4171 4106 4050 4001 3958
3782 3783 3746 3714 3686 3661
3752 3755 3720 3690 3663 3640
3730 3735 3702 3672 3647 3624

6'-0"

6'-6"

36/4
3919
3639
3619
3604

299
478
-

269
430
-

242
387
-

219
350
-

198
317
-

180
288
-

Attachment Pattern
3913 3880 3851
3647 3628 3611
3628 3610 3593
3614 3597 3581

3824
3595
3578
3567

3800
3581
3565
3553

3778
3568
3552
3541

3778
3577
3562
3552

3758
3565
3550
3541

Mno/= 59.1 kip-in/ft


Mno= 90.5 kip-in/ft

Icr = 75.2 in4/ft


Iu = 159.1 in4/ft
7'-0"

7'-6"

8'-0"

8'-6"

9'-0"

36/4
4109
3747
3709
3708

Vn/ = 4.57 kip/ft


Vn = 6.86 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

ASD & LRFD - Superimposed Load, W (psf)


1238 1049 898 777 678 595 526 468 418
1982 1678 1437 1243 1084 953 842 749 669
LRFD - Diaphragm Shear, Sn (plf / ft)
4467 4438 4353 4280 4216 4159
3925 3937 3888 3846 3809 3776
3867 3884 3839 3800 3766 3736
3866 3883 3838 3799 3765 3735

Vn/ = 4.57 kip/ft


Vn = 6.86 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

ASD & LRFD - Superimposed Load, W (psf)


1004 849 726 627 546 479 423 375 334
1607 1359 1162 1004 874 766 676 600 535
-

Concrete + Deck = 57.8 psf


(Icr+Iu)/2 = 127.1 in4/ft

375
600
-

338
541
-

306
489
-

277
443
-

252
403
-

230
367
-

Attachment Pattern
4108 4065 4026
3765 3739 3716
3729 3705 3683
3728 3704 3682

3991
3695
3664
3663

3959
3676
3646
3645

3929
3658
3629
3629

3936
3675
3648
3647

3910
3659
3633
3632

Mno/= 72.4 kip-in/ft


Mno= 110.7 kip-in/ft

Icr = 88.5 in4/ft


Iu = 165.7 in4/ft

Vn/ = 4.57 kip/ft


Vn = 6.86 kip/ft

LRFD - Diaphragm Shear, Sn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width

3/4" Welded Shear Studs


12 in o.c.
24 in o.c.
36 in o.c.

www.ascsd.com

6x6 W1.4xW1.4

As = 0.028 in2/ft
n/a
n/a
n/a

6x6 W2.9xW2.9

As = 0.058 in2/ft
5890
5890
5170

6x6 W4.0xW4.0

As = 0.080 in2/ft
6880
6880
5170

4x4 W4xW4

As = 0.120 in2/ft
8680
7750
5170

4x4 W6xW6

As = 0.180 in2/ft
11380
7750
5170

Composite and Non-Composite Deck Catalog May 2014

ACUSTADEK

All Gages

242
387
-

D PANEL

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

36/4
3844
3597
3579
3565

269
431
-

C PANELS

ASD, W/
LRFD, W
L/360

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

Icr = 69.8 in4/ft


Iu = 156.6 in4/ft

Concrete + Deck = 57.2 psf


(Icr+Iu)/2 = 117.2 in4/ft
Vertical Load Span (in)

9'-0"

N PANELS

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

8'-6"

B PANELS

ASD, W/
LRFD, W
L/360

8'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


4097 4065 4009 3959 3916 3878
3726 3723 3691 3663 3638 3616
3698 3698 3667 3641 3617 3597
3677 3678 3649 3624 3602 3582

Concrete + Deck = 56.9 psf


(Icr+Iu)/2 = 113.2 in4/ft
Vertical Load Span (in)

7'-6"

ASD & LRFD - Superimposed Load, W (psf)


913 772 660 569 495 434 382 339 301
1461 1235 1055 911 792 694 611 542 482
-

2W PANELS

19

6'-0"

3W PANELS

GA

GENERAL INFORMATION

93

TABLE OF CONTENTS

3.3 2WH-36 Composite Deck

6 12" Total Slab Depth


Normal Weight Concrete (145 pcf)

Gage
22
21
20
GA

Concrete Volume 1.687yd3/100ft2


2 Hour Fire Rating

Single
6' - 10"
7' - 7"
8' - 0"
Vertical Load Span (in)
ASD, W/
LRFD, W
L/360

22

Maximum Unshored Span (in)


Triple
Gage
7' - 11"
19
8' - 8"
18
9' - 0"
16

Double
7' - 8"
8' - 4"
8' - 8"

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

6'-0"

6'-6"

830 700
1328 1120
-

7'-0"

ASD, W/
LRFD, W
L/360
21

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

ASD, W/
LRFD, W
L/360
20

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

6'-0"

6'-6"

9'-0"

36/4
4642
4477
4464
4452

Icr = 81.6 in4/ft


Iu = 246.1 in4/ft
7'-0"

7'-6"

8'-0"

8'-6"

9'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


4893 4865 4821 4784 4751 4722
4609 4602 4577 4556 4538 4521
4587 4582 4559 4539 4521 4506
4568 4564 4542 4523 4507 4492

6'-0"

6'-6"

36/4
4696
4507
4492
4479

Icr = 90.2 in4/ft


Iu = 249.7 in4/ft
7'-0"

7'-6"

8'-0"

8'-6"

9'-0"

36/4
4724
4522
4507
4493

Icr = 94.3 in4/ft


Iu = 251.4 in4/ft

Composite and Non-Composite Deck Catalog May 2014

Triple
10' - 2"
10' - 11"
11' - 8"

236
378
-

211
337
-

189
302
-

169
270
-

152
243
-

136
218
-

Attachment Pattern
4632 4614 4597
4476 4465 4456
4464 4454 4445
4452 4443 4434

4582
4447
4436
4427

4568
4439
4429
4419

4555
4432
4422
4413

4552
4433
4424
4415

4541
4426
4417
4409

Mno/= 49.8 kip-in/ft


Mno= 76.2 kip-in/ft

Vn/ = 4.64 kip/ft


Vn = 6.71 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"


272
435
-

243
389
-

218
349
-

196
314
-

177
283
-

160
255
-

Attachment Pattern
4687 4666 4646
4507 4495 4484
4494 4482 4471
4481 4470 4460

4629
4473
4462
4451

4613
4464
4453
4443

4598
4456
4445
4435

4595
4458
4448
4438

4582
4450
4440
4432

Mno/= 56.0 kip-in/ft


Mno= 85.6 kip-in/ft

Vn/ = 5.16 kip/ft


Vn = 7.42 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

ASD & LRFD - Superimposed Load, W (psf)


993 838 716 617 536 469 413 365 324
1588 1341 1145 987 857 750 660 584 519
LRFD - Diaphragm Shear, Sn (plf / ft)
4934 4904 4858 4818 4783 4752
4630 4624 4598 4575 4555 4538
4607 4603 4578 4557 4538 4521
4587 4584 4561 4541 4523 4507

Double
9' - 10"
10' - 6"
11' - 10"

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

ASD & LRFD - Superimposed Load, W (psf)


940 793 677 583 506 442 389 344 305
1503 1269 1083 932 810 708 622 550 488
-

Concrete + Deck = 68.9 psf


(Icr+Iu)/2 = 173 in4/ft

94

8'-6"

LRFD - Diaphragm Shear, Sn (plf / ft)


4814 4787 4750 4718 4689 4664
4567 4559 4538 4519 4503 4489
4547 4541 4521 4504 4489 4476
4529 4524 4506 4490 4475 4463

Concrete + Deck = 68.8 psf


(Icr+Iu)/2 = 170 in4/ft
Vertical Load Span (in)

8'-0"

ASD & LRFD - Superimposed Load, W (psf)


596 513 444 388 340 300 266
954 820 711 621 545 480 426
-

Concrete + Deck = 68.6 psf


(Icr+Iu)/2 = 164 in4/ft
Vertical Load Span (in)

7'-6"

Single
8' - 7"
8' - 11"
9' - 6"

289
463
-

259
415
-

233
372
-

209
335
-

189
302
-

171
273
-

Attachment Pattern
4715 4692 4672
4524 4510 4498
4509 4496 4485
4496 4484 4474

4653
4487
4475
4464

4636
4477
4465
4455

4620
4468
4456
4447

4617
4471
4460
4451

4603
4463
4452
4443

Mno/= 59.0 kip-in/ft


Mno= 90.2 kip-in/ft

Vn/ = 5.45 kip/ft


Vn = 7.81 kip/ft

www.ascsd.com

TABLE OF CONTENTS

2WH-36 Composite Deck 3.3


6 12" Total Slab Depth
Normal Weight Concrete (145 pcf)

Concrete Volume 1.987yd3/100ft2


2 Hour Fire Rating

Vertical Load Span (in)


ASD, W/
LRFD, W
L/360
Arc Spot Weld 1/2" Effective Dia
PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

6'-6"

7'-0"

18

6'-0"

6'-6"

16

282
452
-

255
408
-

231
370
-

210
336
-

Attachment Pattern
4817 4789 4763
4583 4566 4551
4566 4550 4536
4552 4537 4523

4740
4538
4523
4511

4719
4525
4511
4500

4699
4514
4500
4489

4698
4520
4507
4497

4681
4510
4497
4487

Mno/= 69.4 kip-in/ft


Mno= 106.1 kip-in/ft

7'-0"

7'-6"

8'-0"

8'-6"

9'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


5183 5152 5087 5031 4982 4939
4763 4764 4727 4695 4667 4642
4733 4736 4701 4671 4644 4620
4711 4716 4682 4653 4628 4605

6'-0"

6'-6"

36/4
4900
4620
4600
4585

388
620
-

349
558
-

314
503
-

285
455
-

258
413
-

235
376
-

Attachment Pattern
4893 4861 4832
4628 4609 4592
4609 4591 4574
4595 4578 4562

4805
4576
4559
4547

4781
4562
4546
4534

4758
4548
4533
4522

4759
4558
4543
4532

4739
4546
4531
4521

Mno/= 76.1 kip-in/ft


Mno= 116.4 kip-in/ft

Icr = 116.5 in4/ft


Iu = 261.2 in4/ft
7'-0"

7'-6"

8'-0"

8'-6"

9'-0"

36/4
5090
4728
4690
4689

Vn/ = 5.74 kip/ft


Vn = 8.61 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

ASD & LRFD - Superimposed Load, W (psf)


1601 1357 1163 1006 878 771 682 607 543
2562 2171 1860 1609 1404 1234 1092 971 868
LRFD - Diaphragm Shear, Sn (plf / ft)
5448 5419 5334 5261 5197 5140
4905 4918 4869 4827 4790 4757
4848 4865 4820 4781 4747 4716
4847 4864 4819 4780 4745 4715

Vn/ = 5.74 kip/ft


Vn = 8.61 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

ASD & LRFD - Superimposed Load, W (psf)


1295 1095 937 810 705 619 546 485 433
2071 1753 1500 1296 1129 990 874 776 692
-

Concrete + Deck = 70.2 psf


(Icr+Iu)/2 = 204.4 in4/ft

487
780
-

439
703
-

398
636
-

361
577
-

328
526
-

300
480
-

Attachment Pattern
5088 5046 5007
4746 4720 4697
4710 4686 4664
4709 4685 4663

4972
4676
4645
4644

4940
4657
4627
4626

4910
4639
4610
4610

4917
4656
4629
4628

4890
4640
4613
4613

Mno/= 93.4 kip-in/ft


Mno= 142.9 kip-in/ft

Icr = 137.6 in4/ft


Iu = 271.2 in4/ft

Vn/ = 5.74 kip/ft


Vn = 8.61 kip/ft

LRFD - Diaphragm Shear, Sn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width

3/4" Welded Shear Studs


12 in o.c.
24 in o.c.
36 in o.c.

www.ascsd.com

6x6 W1.4xW1.4

As = 0.028 in2/ft
n/a
n/a
n/a

6x6 W2.9xW2.9

As = 0.058 in2/ft
6880
6880
5170

6x6 W4.0xW4.0

As = 0.080 in2/ft
7870
7750
5170

4x4 W4xW4

As = 0.120 in2/ft
9670
7750
5170

4x4 W6xW6

As = 0.180 in2/ft
12370
7750
5170

Composite and Non-Composite Deck Catalog May 2014

ACUSTADEK

All Gages

313
502
-

D PANEL

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

36/4
4825
4578
4560
4546

349
559
-

C PANELS

ASD, W/
LRFD, W
L/360

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

Icr = 107.9 in4/ft


Iu = 257.4 in4/ft

Concrete + Deck = 69.5 psf


(Icr+Iu)/2 = 188.9 in4/ft
Vertical Load Span (in)

9'-0"

N PANELS

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

8'-6"

B PANELS

ASD, W/
LRFD, W
L/360

8'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


5077 5046 4989 4940 4897 4859
4707 4704 4672 4644 4619 4597
4679 4679 4648 4622 4598 4578
4658 4659 4630 4605 4582 4563

Concrete + Deck = 69.3 psf


(Icr+Iu)/2 = 183 in4/ft
Vertical Load Span (in)

7'-6"

ASD & LRFD - Superimposed Load, W (psf)


1176 995 850 734 639 560 494 438 390
1882 1591 1361 1175 1022 896 790 701 624
-

2W PANELS

19

6'-0"

3W PANELS

GA

GENERAL INFORMATION

95

TABLE OF CONTENTS

3.3 2WH-36 Composite Deck

7 14" Total Slab Depth


Normal Weight Concrete (145 pcf)

Gage
22
21
20
GA

Concrete Volume 1.910yd3/100ft2


3 Hour Fire Rating

Single
6' - 7"
7' - 3"
7' - 7"
Vertical Load Span (in)
ASD, W/
LRFD, W
L/360

22

Maximum Unshored Span (in)


Triple
Gage
7' - 7"
19
8' - 3"
18
8' - 7"
16

Double
7' - 4"
8' - 0"
8' - 3"

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

6'-0"

6'-6"

7'-0"

ASD, W/
LRFD, W
L/360
21

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

ASD, W/
LRFD, W
L/360
20

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

6'-0"

6'-6"

9'-0"

36/4
5377
5212
5199
5187

Icr = 107.5 in4/ft


Iu = 342.3 in4/ft
7'-0"

7'-6"

8'-0"

8'-6"

9'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


5629 5600 5557 5520 5487 5458
5344 5338 5313 5292 5273 5257
5322 5317 5294 5274 5257 5241
5303 5300 5278 5259 5242 5228

6'-0"

6'-6"

36/4
5432
5242
5228
5215

Icr = 119.0 in4/ft


Iu = 346.9 in4/ft
7'-0"

7'-6"

8'-0"

8'-6"

9'-0"

36/4
5460
5258
5242
5229

Icr = 124.4 in4/ft


Iu = 349.1 in4/ft

Composite and Non-Composite Deck Catalog May 2014

Triple
9' - 8"
10' - 4"
11' - 4"

278
445
-

248
397
-

222
355
-

199
319
-

179
286
-

161
258
-

Attachment Pattern
5368 5350 5333
5212 5201 5191
5199 5189 5180
5188 5179 5170

5318
5183
5172
5162

5304
5175
5164
5155

5291
5167
5158
5149

5287
5169
5159
5151

5276
5162
5153
5145

Mno/= 58.2 kip-in/ft


Mno= 89.0 kip-in/ft

Vn/ = 5.11 kip/ft


Vn = 7.42 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"


320
512
-

286
458
-

257
411
-

231
370
-

208
334
-

188
301
-

Attachment Pattern
5423 5401 5382
5243 5231 5219
5229 5217 5207
5217 5206 5196

5364
5209
5197
5187

5348
5200
5188
5178

5334
5191
5180
5171

5330
5194
5183
5174

5318
5186
5176
5167

Mno/= 65.4 kip-in/ft


Mno= 100.1 kip-in/ft

Vn/ = 5.63 kip/ft


Vn = 8.13 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

ASD & LRFD - Superimposed Load, W (psf)


1163 982 839 723 628 550 484 429 381
1861 1571 1342 1157 1006 880 775 686 610
LRFD - Diaphragm Shear, Sn (plf / ft)
5669 5640 5594 5553 5518 5487
5366 5360 5333 5311 5291 5273
5343 5338 5314 5292 5273 5257
5323 5320 5297 5276 5259 5243

Double
9' - 4"
10' - 0"
11' - 3"

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

ASD & LRFD - Superimposed Load, W (psf)


1100 929 793 683 593 519 456 404 359
1760 1486 1268 1093 949 830 730 646 574
-

Concrete + Deck = 78.2 psf


(Icr+Iu)/2 = 236.8 in4/ft

96

8'-6"

LRFD - Diaphragm Shear, Sn (plf / ft)


5550 5523 5486 5453 5425 5400
5302 5294 5273 5255 5239 5225
5283 5277 5257 5240 5225 5211
5265 5260 5241 5225 5211 5199

Concrete + Deck = 78.0 psf


(Icr+Iu)/2 = 232.9 in4/ft
Vertical Load Span (in)

8'-0"

ASD & LRFD - Superimposed Load, W (psf)


971 819 698 601 521 455 399 352 312
1554 1311 1117 961 833 728 639 564 500
-

Concrete + Deck = 77.8 psf


(Icr+Iu)/2 = 224.9 in4/ft
Vertical Load Span (in)

7'-6"

Single
8' - 3"
8' - 6"
9' - 2"

340
544
-

305
488
-

274
438
-

247
395
-

223
357
-

202
323
-

Attachment Pattern
5451 5428 5407
5259 5246 5234
5245 5232 5221
5232 5220 5209

5388
5223
5210
5199

5371
5213
5201
5190

5355
5204
5192
5182

5353
5207
5196
5186

5339
5199
5188
5179

Mno/= 69.0 kip-in/ft


Mno= 105.5 kip-in/ft

Vn/ = 5.92 kip/ft


Vn = 8.52 kip/ft

www.ascsd.com

TABLE OF CONTENTS

2WH-36 Composite Deck 3.3


7 14" Total Slab Depth
Normal Weight Concrete (145 pcf)

Concrete Volume 1.910yd3/100ft2


3 Hour Fire Rating

Vertical Load Span (in)


ASD, W/
LRFD, W
L/360
Arc Spot Weld 1/2" Effective Dia
PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

6'-6"

7'-0"

18

6'-0"

6'-6"

16

333
532
-

301
481
-

273
436
-

248
396
-

Attachment Pattern
5553 5524 5499
5319 5302 5287
5301 5286 5271
5288 5273 5259

5475
5273
5258
5247

5454
5261
5246
5235

5435
5249
5236
5225

5434
5256
5242
5232

5416
5245
5233
5223

Mno/= 81.2 kip-in/ft


Mno= 124.3 kip-in/ft

7'-0"

7'-6"

8'-0"

8'-6"

9'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


5919 5888 5823 5767 5718 5674
5499 5500 5463 5431 5403 5378
5468 5472 5437 5406 5380 5356
5447 5452 5418 5389 5363 5341

6'-0"

6'-6"

36/4
5636
5356
5335
5321

456
730
-

411
657
-

371
593
-

336
537
-

305
487
-

277
443
-

Attachment Pattern
5629 5597 5567
5364 5345 5327
5345 5326 5310
5331 5313 5298

5541
5312
5295
5283

5516
5297
5281
5270

5494
5284
5269
5258

5495
5293
5278
5268

5475
5281
5267
5257

Mno/= 89.1 kip-in/ft


Mno= 136.4 kip-in/ft

Icr = 154.3 in4/ft


Iu = 362.0 in4/ft
7'-0"

7'-6"

8'-0"

8'-6"

9'-0"

36/4
5825
5463
5425
5424

Vn/ = 6.68 kip/ft


Vn = 10.02 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

ASD & LRFD - Superimposed Load, W (psf)


1883 1595 1367 1183 1033 908 804 715 640
3012 2552 2188 1893 1653 1453 1286 1144 1023
LRFD - Diaphragm Shear, Sn (plf / ft)
6184 6154 6070 5996 5932 5876
5641 5654 5605 5562 5525 5493
5584 5601 5556 5516 5482 5452
5582 5599 5554 5515 5481 5451

Vn/ = 6.68 kip/ft


Vn = 9.59 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

ASD & LRFD - Superimposed Load, W (psf)


1519 1286 1101 951 829 727 642 571 509
2431 2057 1761 1522 1326 1164 1028 913 815
-

Concrete + Deck = 79.4 psf


(Icr+Iu)/2 = 278.9 in4/ft

575
919
-

518
829
-

469
751
-

426
682
-

388
621
-

354
567
-

Attachment Pattern
5824 5781 5743
5481 5456 5433
5445 5421 5400
5444 5420 5399

5707
5412
5380
5379

5675
5392
5362
5362

5646
5375
5346
5345

5652
5392
5364
5364

5626
5376
5349
5348

Mno/= 109.7 kip-in/ft


Mno= 167.8 kip-in/ft

Icr = 182.8 in4/ft


Iu = 375.1 in4/ft

Vn/ = 6.68 kip/ft


Vn = 10.02 kip/ft

LRFD - Diaphragm Shear, Sn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width

3/4" Welded Shear Studs


12 in o.c.
24 in o.c.
36 in o.c.

www.ascsd.com

6x6 W1.4xW1.4

As = 0.028 in2/ft
n/a
n/a
n/a

6x6 W2.9xW2.9

As = 0.058 in2/ft
7620
7620
5170

6x6 W4.0xW4.0

As = 0.080 in2/ft
8610
7750
5170

4x4 W4xW4

As = 0.120 in2/ft
10410
7750
5170

4x4 W6xW6

As = 0.180 in2/ft
13110
7750
5170

Composite and Non-Composite Deck Catalog May 2014

ACUSTADEK

All Gages

369
591
-

D PANEL

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

36/4
5561
5314
5295
5281

411
657
-

C PANELS

ASD, W/
LRFD, W
L/360

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

Icr = 142.8 in4/ft


Iu = 357.0 in4/ft

Concrete + Deck = 78.8 psf


(Icr+Iu)/2 = 258.1 in4/ft
Vertical Load Span (in)

9'-0"

N PANELS

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

8'-6"

B PANELS

ASD, W/
LRFD, W
L/360

8'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


5813 5782 5725 5676 5633 5595
5442 5440 5407 5379 5355 5333
5415 5414 5384 5357 5334 5314
5394 5395 5366 5340 5318 5299

Concrete + Deck = 78.5 psf


(Icr+Iu)/2 = 249.9 in4/ft
Vertical Load Span (in)

7'-6"

ASD & LRFD - Superimposed Load, W (psf)


1380 1167 998 862 750 658 580 515 459
2207 1867 1597 1379 1200 1053 929 824 734
-

2W PANELS

19

6'-0"

3W PANELS

GA

GENERAL INFORMATION

97

TABLE OF CONTENTS

3.3 2WH-36 Composite Deck


4" Total Slab Depth
Light Weight Concrete (110 pcf)

Gage
22
21
20
GA

22

Concrete Volume 0.907yd3/100ft2

Single
11' - 10"
13' - 0"
13' - 2"

Maximum Unshored Span (in)


Triple
Gage
13' - 6"
19
14' - 8"
18
15' - 3"
16

Double
13' - 0"
14' - 2"
14' - 9"

Vertical Load Span (in)

6'-0"

6'-6"

ASD, W/
LRFD, W
L/360

326
521
-

275
439
-

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

7'-0"

ASD, W/
LRFD, W
L/360
21

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

7'-6"

8'-0"

8'-6"

84
134
-

75
120
-

67
108
-

61
97
-

55
87
-

36/4 Attachment Pattern


1014 1004 986 969
846 845 835 825
833 833 823 814
821 821 812 803

953
816
805
795

939
808
798
788

926
800
791
781

922
802
792
783

911
795
786
777

367
587
-

6'-0"

6'-6"

ASD, W/
LRFD, W
L/360

387
619
-

327
523
-

9'-0"

Mno/= 19.4 kip-in/ft


Mno= 29.8 kip-in/ft

ASD & LRFD - Superimposed Load, W (psf)


310 264 228 198 173 152 135 120
496 423 365 317 277 244 216 192
-

LRFD - Diaphragm Shear, Sn (plf / ft)


1271 1242 1198 1160 1126 1097
982 974 950 928 909 893
959 954 931 910 893 877
940 936 914 895 878 863

7'-6"

8'-0"

8'-6"

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"


86
138
-

77
124
-

70
112
-

63
101
-

36/4 Attachment Pattern


1071 1061 1040 1020 1002
878 878 866 854 844
863 864 852 842 832
850 852 841 831 821

986
835
823
813

971
826
815
805

967
828
818
808

954
821
810
801

9'-0"

107
171
-

Mno/= 21.8 kip-in/ft


Mno= 33.3 kip-in/ft

Vn/ = 2.20 kip/ft


Vn = 4.17 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

ASD & LRFD - Superimposed Load, W (psf)


279 241 209 183 161 143 127
447 385 335 293 258 229 204
-

LRFD - Diaphragm Shear, Sn (plf / ft)


1313 1282 1235 1195 1159 1128
1004 997 971 948 928 910
980 976 951 929 910 893
960 957 933 913 895 879

Vn/ = 2.20 kip/ft


Vn = 3.36 kip/ft

96
153
-

Icr = 33.7 in4/ft


Iu = 57.6 in4/ft
7'-0"

Triple
16' - 1"
16' - 6"
17' - 4"

94
150
-

Icr = 30.0 in4/ft


Iu = 55.9 in4/ft
7'-0"

Double
16' - 2"
17' - 1"
18' - 5"

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

6'-6"

Concrete + Deck = 25.4 psf


(Icr+Iu)/2 = 47 in4/ft

98

9'-0"

6'-0"

Vertical Load Span (in)

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

8'-6"

LRFD - Diaphragm Shear, Sn (plf / ft)


1190 1162 1124 1091 1062 1037
938 930 908 889 873 859
918 911 891 874 858 845
900 895 876 859 845 832

Concrete + Deck = 25.3 psf


(Icr+Iu)/2 = 45.6 in4/ft

20

8'-0"

ASD & LRFD - Superimposed Load, W (psf)


234 202 175 153 134 119 105
375 323 280 244 215 190 168
-

Concrete + Deck = 25.1 psf


(Icr+Iu)/2 = 42.9 in4/ft
Vertical Load Span (in)

7'-6"

Single
13' - 9"
14' - 1"
14' - 10"

92
146
-

83
132
-

74
119
74

66
108
66

36/4 Attachment Pattern


1100 1090 1067 1046 1027 1009
894 895 882 870 859 848
878 881 868 856 846 836
865 868 856 845 835 826

993
839
827
817

991
842
831
821

976
834
823
814

Icr = 35.5 in4/ft


Iu = 58.5 in4/ft

Composite and Non-Composite Deck Catalog May 2014

114
182
-

102
163
-

Mno/= 22.9 kip-in/ft


Mno= 35.1 kip-in/ft

Vn/ = 2.20 kip/ft


Vn = 4.41 kip/ft

www.ascsd.com

TABLE OF CONTENTS

2WH-36 Composite Deck 2.3


4" Total Slab Depth
Light Weight Concrete (110 pcf)

Vertical Load Span (in)


ASD, W/
LRFD, W
L/360
Arc Spot Weld 1/2" Effective Dia
PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

6'-6"

459
734
-

ASD & LRFD - Superimposed Load, W (psf)


388 332 287 250 219 193 171 153
621 531 459 399 350 309 274 244
-

7'-0"

18

7'-0"

8'-0"

8'-6"

509
815
-

ASD & LRFD - Superimposed Load, W (psf)


431 369 319 278 244 216 191 170
690 590 510 445 390 345 306 273
170

LRFD - Diaphragm Shear, Sn (plf / ft)


1570 1537 1472 1415 1365 1321
1143 1143 1106 1073 1045 1020
1112 1115 1079 1048 1021 998
1090 1094 1060 1031 1005 982

6'-6"

ASD, W/
LRFD, W
L/360

631
1010
-

535
856
-

9'-0"

7'-6"

8'-0"

8'-6"

82
145
82

73
132
73

Vn/ = 2.20 kip/ft


Vn = 4.41 kip/ft

147
245
147

127
221
127

112
199
112

98
180
98

87
164
87

77
149
77

36/4 Attachment Pattern


1282 1275 1242 1212 1185 1161 1138 1138 1118
997 1005 986 968 952 938 925 933 921
977 986 967 951 935 922 909 918 907
962 972 954 938 923 910 898 908 897
Mno/= 29.9 kip-in/ft
Mno= 45.7 kip-in/ft

9'-0"

88
190
88

146
278
146

128
252
128

Attachment Pattern
1476 1433 1394
1128 1102 1079
1091 1067 1045
1090 1066 1044

1358
1057
1025
1025

1326 1296 1302 1275


1038 1020 1037 1021
1007 991 1009 994
1007 990 1008 993

Mno/= 36.8 kip-in/ft


Mno= 56.3 kip-in/ft

Icr = 57.3 in4/ft


Iu = 68.3 in4/ft

112
228
112

99
208
99

168
308
168

Vn/ = 2.20 kip/ft


Vn = 4.41 kip/ft

D PANEL

36/4
1478
1110
1071
1070

Vn/ = 2.20 kip/ft


Vn = 4.41 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

ASD & LRFD - Superimposed Load, W (psf)


459 397 346 305 266 226 194
734 635 554 487 431 384 343
266 226 194

LRFD - Diaphragm Shear, Sn (plf / ft)


1842 1812 1726 1652 1587 1529
1291 1303 1253 1210 1173 1140
1232 1249 1203 1164 1129 1098
1231 1247 1202 1162 1128 1097

92
160
92

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

Icr = 46.4 in4/ft


Iu = 63.5 in4/ft
7'-0"

105
177
105

C PANELS

6'-0"

120
197
120

Mno/= 27.0 kip-in/ft


Mno= 41.3 kip-in/ft

6'-6"

Concrete + Deck = 26.7 psf


(Icr+Iu)/2 = 62.8 in4/ft

LRFD - Diaphragm Shear, Sn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width

3/4" Welded Shear Studs


12 in o.c.
24 in o.c.
36 in o.c.

www.ascsd.com

6x6 W1.4xW1.4

As = 0.028 in2/ft
1960
1960
1960

6x6 W2.9xW2.9

As = 0.058 in2/ft
3310
3310
3310

6x6 W4.0xW4.0

As = 0.080 in2/ft
4300
4300
4300

4x4 W4xW4

As = 0.120 in2/ft
6100
6100
5170

4x4 W6xW6

As = 0.180 in2/ft
8800
7750
5170

Composite and Non-Composite Deck Catalog May 2014

ACUSTADEK

All Gages

7'-6"

137
219
-

36/4 Attachment Pattern


1204 1196 1167 1141 1118 1096 1076 1075 1057
953 958 941 926 912 899 888 894 883
934 940 924 910 897 885 874 881 871
920 927 911 898 885 873 863 870 861

6'-0"

Vertical Load Span (in)

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

Icr = 41.8 in4/ft


Iu = 61.5 in4/ft

Concrete + Deck = 26.1 psf


(Icr+Iu)/2 = 54.9 in4/ft

16

9'-0"

N PANELS

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

8'-6"

B PANELS

ASD, W/
LRFD, W
L/360

8'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


1461 1429 1371 1321 1277 1239
1084 1081 1048 1020 995 973
1056 1055 1024 997 974 953
1034 1035 1006 980 958 938

Concrete + Deck = 25.8 psf


(Icr+Iu)/2 = 51.6 in4/ft
Vertical Load Span (in)

7'-6"

2W PANELS

19

6'-0"

3W PANELS

GA

Concrete Volume 0.907yd3/100ft2

GENERAL INFORMATION

99

TABLE OF CONTENTS

3.3 2WH-36 Composite Deck

4 12" Total Slab Depth


Light Weight Concrete (110 pcf)

Concrete Volume 1.061yd3/100ft2
1 Hour Fire Rating

Gage
22
21
20
GA

22

Single
8' - 10"
9' - 10"
10' - 2"

Maximum Unshored Span (in)


Triple
Gage
10' - 2"
19
11' - 1"
18
11' - 6"
16

Double
9' - 8"
10' - 8"
11' - 2"

Vertical Load Span (in)

6'-0"

6'-6"

ASD, W/
LRFD, W
L/360

459
735
-

388
620
-

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

7'-0"

ASD, W/
LRFD, W
L/360
21

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

36/4
1899
1734
1721
1709

Icr = 42.5 in4/ft


Iu = 87.7 in4/ft
7'-0"

7'-6"

8'-0"

8'-6"

119
190
-

107
171
-

96
153
-

86
138
-

78
125
-

Attachment Pattern
1890 1872 1855
1734 1723 1713
1721 1711 1702
1710 1701 1692

1840
1705
1694
1684

1826
1697
1686
1677

1813
1689
1680
1671

1809
1691
1681
1673

1798
1684
1675
1667

Mno/= 27.4 kip-in/ft


Mno= 41.9 kip-in/ft

517
827
-

6'-0"

6'-6"

ASD, W/
LRFD, W
L/360

544
870
-

460
736
-

36/4
1955
1766
1751
1738

Icr = 46.5 in4/ft


Iu = 89.8 in4/ft
7'-0"

7'-6"

8'-0"

8'-6"

9'-0"

36/4
1984
1782
1766
1753

Icr = 48.4 in4/ft


Iu = 90.8 in4/ft

Composite and Non-Composite Deck Catalog May 2014

Vn/ = 2.63 kip/ft


Vn = 4.38 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"


152
243
-

136
217
-

122
195
-

110
176
-

99
159
-

90
144
-

Attachment Pattern
1946 1925 1905
1766 1754 1743
1752 1741 1730
1740 1729 1719

1888
1732
1720
1710

1872
1723
1712
1702

1857
1715
1704
1694

1854
1717
1707
1697

1841
1709
1699
1690

Mno/= 30.6 kip-in/ft


Mno= 46.8 kip-in/ft

Vn/ = 2.63 kip/ft


Vn = 5.09 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

ASD & LRFD - Superimposed Load, W (psf)


393 339 295 258 228 202 180
629 542 472 413 364 323 287
-

LRFD - Diaphragm Shear, Sn (plf / ft)


2193 2164 2118 2077 2042 2011
1890 1884 1857 1835 1815 1797
1867 1862 1838 1816 1797 1781
1847 1844 1821 1800 1783 1767

Triple
12' - 9"
13' - 1"
13' - 9"

133
213
-

ASD & LRFD - Superimposed Load, W (psf)


436 373 321 279 245 215 191 170
698 597 514 447 391 345 305 272
-

LRFD - Diaphragm Shear, Sn (plf / ft)


2152 2124 2080 2043 2010 1981
1868 1861 1836 1815 1797 1780
1846 1841 1818 1798 1780 1765
1826 1823 1801 1782 1766 1751

9'-0"

Double
12' - 6"
13' - 5"
14' - 8"

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

6'-6"

Concrete + Deck = 34.0 psf


(Icr+Iu)/2 = 69.6 in4/ft

100

9'-0"

6'-0"

Vertical Load Span (in)

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

8'-6"

LRFD - Diaphragm Shear, Sn (plf / ft)


2072 2045 2008 1975 1947 1922
1824 1816 1795 1777 1761 1747
1805 1799 1779 1762 1746 1733
1787 1782 1763 1747 1733 1721

Concrete + Deck = 33.9 psf


(Icr+Iu)/2 = 68.16 in4/ft

20

8'-0"

ASD & LRFD - Superimposed Load, W (psf)


331 285 247 216 190 168 149
529 456 396 346 304 269 239
-

Concrete + Deck = 33.7 psf


(Icr+Iu)/2 = 65.12 in4/ft
Vertical Load Span (in)

7'-6"

Single
10' - 10"
11' - 2"
11' - 9"

160
257
-

144
230
-

130
207
-

117
187
-

106
169
-

96
153
-

Attachment Pattern
1975 1952 1931
1783 1770 1758
1769 1756 1745
1756 1744 1733

1912
1747
1734
1723

1895
1737
1725
1714

1879
1728
1716
1706

1877
1731
1720
1710

1863
1723
1712
1703

Mno/= 32.2 kip-in/ft


Mno= 49.2 kip-in/ft

Vn/ = 2.63 kip/ft


Vn = 5.26 kip/ft

www.ascsd.com

TABLE OF CONTENTS

2WH-36 Composite Deck 3.3


4 12" Total Slab Depth
Light Weight Concrete (110 pcf)

Concrete Volume 1.061yd3/100ft2


1 Hour Fire Rating

Vertical Load Span (in)


ASD, W/
LRFD, W
L/360
Arc Spot Weld 1/2" Effective Dia
PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

6'-6"

638
1021
-

ASD & LRFD - Superimposed Load, W (psf)


540 462 399 348 305 269 239 213
864 739 639 556 488 431 383 341
-

7'-0"

18

16

151
248
151

133
224
133

118
204
118

105
185
105

Attachment Pattern
2079 2051 2025
1845 1828 1813
1828 1812 1798
1814 1799 1785

2002
1800
1785
1773

1980
1787
1773
1762

1961
1776
1762
1751

1960
1782
1769
1759

1943
1772
1759
1749

Mno/= 37.5 kip-in/ft


Mno= 57.4 kip-in/ft

6'-0"

6'-6"

699
1119
-

ASD & LRFD - Superimposed Load, W (psf)


592 507 438 382 335 296 263 235
947 811 701 611 537 474 421 376
-

7'-0"

7'-6"

8'-0"

8'-6"

LRFD - Diaphragm Shear, Sn (plf / ft)


2447 2415 2351 2295 2245 2202
2027 2028 1991 1959 1931 1906
1996 2000 1964 1934 1908 1884
1975 1980 1946 1917 1891 1869

6'-0"

6'-6"

9'-0"

36/4
2164
1884
1863
1849

7'-0"

7'-6"

8'-0"

8'-6"

9'-0"

207
337
207

180
304
180

157
274
157

138
249
138

122
226
122

109
206
109

Attachment Pattern
2157 2125 2095
1892 1873 1855
1872 1854 1838
1859 1841 1826

2069
1840
1823
1811

2044
1825
1809
1798

2022
1812
1797
1786

2023
1821
1806
1796

2003
1809
1795
1785

Mno/= 41.0 kip-in/ft


Mno= 62.7 kip-in/ft

36/4
2357
1995
1957
1956

Vn/ = 2.63 kip/ft


Vn = 5.26 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

ASD & LRFD - Superimposed Load, W (psf)


853 723 620 537 468 412 359 305 262
1365 1157 992 859 750 659 583 519 464
359 305 262
LRFD - Diaphragm Shear, Sn (plf / ft)
2716 2686 2602 2528 2464 2408
2173 2186 2137 2094 2057 2025
2116 2133 2087 2048 2014 1984
2114 2131 2086 2047 2013 1983

Vn/ = 2.63 kip/ft


Vn = 5.26 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

Icr = 58.5 in4/ft


Iu = 96.3 in4/ft

Concrete + Deck = 35.3 psf


(Icr+Iu)/2 = 84.73 in4/ft

226
417
226

197
377
197

172
341
172

151
310
151

134
282
134

119
258
119

Attachment Pattern
2356 2313 2275
2013 1988 1965
1977 1953 1932
1976 1952 1931

2239
1944
1912
1911

2207
1924
1894
1894

2178
1907
1878
1877

2184
1924
1896
1896

2158
1908
1881
1880

Mno/= 49.7 kip-in/ft


Mno= 76.0 kip-in/ft

Icr = 67.7 in4/ft


Iu = 101.8 in4/ft

Vn/ = 2.63 kip/ft


Vn = 5.26 kip/ft

LRFD - Diaphragm Shear, Sn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width

3/4" Welded Shear Studs


12 in o.c.
24 in o.c.
36 in o.c.

www.ascsd.com

6x6 W1.4xW1.4

As = 0.028 in2/ft
2980
2980
2980

6x6 W2.9xW2.9

As = 0.058 in2/ft
4330
4330
4330

6x6 W4.0xW4.0

As = 0.080 in2/ft
5320
5320
5170

4x4 W4xW4

As = 0.120 in2/ft
7120
7120
5170

4x4 W6xW6

As = 0.180 in2/ft
9820
7750
5170

Composite and Non-Composite Deck Catalog May 2014

ACUSTADEK

All Gages

172
275
-

D PANEL

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

191
306
-

C PANELS

ASD, W/
LRFD, W
L/360

36/4
2087
1840
1822
1807

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

Icr = 54.6 in4/ft


Iu = 94.1 in4/ft

Concrete + Deck = 34.7 psf


(Icr+Iu)/2 = 77.4 in4/ft
Vertical Load Span (in)

9'-0"

N PANELS

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

8'-6"

B PANELS

ASD, W/
LRFD, W
L/360

8'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


2339 2308 2251 2202 2159 2121
1969 1966 1934 1906 1881 1859
1941 1941 1910 1884 1860 1840
1920 1921 1892 1867 1844 1825

Concrete + Deck = 34.4 psf


(Icr+Iu)/2 = 74.37 in4/ft
Vertical Load Span (in)

7'-6"

2W PANELS

19

6'-0"

3W PANELS

GA

GENERAL INFORMATION

101

TABLE OF CONTENTS

3.3 2WH-36 Composite Deck


5" Total Slab Depth
Light Weight Concrete (110 pcf)

Gage
22
21
20
GA

22

Concrete Volume 1.125yd3/100ft2

Single
8' - 5"
9' - 5"
9' - 9"

Maximum Unshored Span (in)


Triple
Gage
9' - 9"
19
10' - 8"
18
11' - 1"
16

Double
9' - 4"
10' - 3"
10' - 8"

Vertical Load Span (in)

6'-0"

6'-6"

ASD, W/
LRFD, W
L/360

543
869
-

459
734
-

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

7'-0"

ASD, W/
LRFD, W
L/360
21

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

36/4
2223
2058
2045
2033

Icr = 56.3 in4/ft


Iu = 119.3 in4/ft
7'-0"

7'-6"

8'-0"

8'-6"

141
226
-

127
203
-

114
183
-

103
165
-

93
149
-

Attachment Pattern
2214 2196 2179
2058 2047 2037
2045 2035 2026
2034 2025 2016

2164
2029
2018
2008

2150
2021
2011
2001

2137
2013
2004
1995

2133
2015
2005
1997

2122
2008
1999
1991

Mno/= 32.3 kip-in/ft


Mno= 49.4 kip-in/ft

612
979
-

6'-0"

6'-6"

ASD, W/
LRFD, W
L/360

644
1031
-

545
872
-

36/4
2279
2090
2075
2062

Icr = 61.7 in4/ft


Iu = 122.0 in4/ft
7'-0"

7'-6"

8'-0"

8'-6"

9'-0"

36/4
2308
2106
2090
2077

Icr = 64.2 in4/ft


Iu = 123.3 in4/ft

Composite and Non-Composite Deck Catalog May 2014

Vn/ = 3.02 kip/ft


Vn = 4.67 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"


180
288
-

162
259
-

145
233
-

131
210
-

119
190
-

108
172
-

Attachment Pattern
2270 2249 2229
2090 2078 2067
2077 2065 2054
2064 2053 2043

2212
2056
2045
2034

2196
2047
2036
2026

2181
2039
2028
2018

2178
2041
2031
2021

2165
2034
2023
2015

Mno/= 36.2 kip-in/ft


Mno= 55.4 kip-in/ft

Vn/ = 3.02 kip/ft


Vn = 5.38 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

ASD & LRFD - Superimposed Load, W (psf)


466 402 350 307 270 240 213
745 643 560 490 432 383 341
-

LRFD - Diaphragm Shear, Sn (plf / ft)


2517 2488 2442 2402 2366 2336
2214 2208 2181 2159 2139 2121
2191 2186 2162 2140 2121 2105
2171 2168 2145 2124 2107 2091

Triple
12' - 4"
12' - 8"
13' - 4"

158
253
-

ASD & LRFD - Superimposed Load, W (psf)


517 442 381 331 290 256 227 202
827 707 610 530 464 409 363 323
-

LRFD - Diaphragm Shear, Sn (plf / ft)


2476 2448 2404 2367 2334 2305
2192 2185 2160 2139 2121 2104
2170 2165 2142 2122 2104 2089
2151 2147 2125 2106 2090 2075

9'-0"

Double
12' - 1"
12' - 11"
14' - 3"

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

6'-6"

Concrete + Deck = 38.7 psf


(Icr+Iu)/2 = 93.72 in4/ft

102

9'-0"

6'-0"

Vertical Load Span (in)

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

8'-6"

LRFD - Diaphragm Shear, Sn (plf / ft)


2396 2369 2332 2299 2271 2246
2148 2141 2119 2101 2085 2071
2129 2123 2103 2086 2071 2057
2111 2106 2087 2071 2057 2045

Concrete + Deck = 38.6 psf


(Icr+Iu)/2 = 91.84 in4/ft

20

8'-0"

ASD & LRFD - Superimposed Load, W (psf)


392 337 293 256 226 199 177
627 540 469 410 361 319 284
-

Concrete + Deck = 38.4 psf


(Icr+Iu)/2 = 87.82 in4/ft
Vertical Load Span (in)

7'-6"

Single
10' - 4"
10' - 9"
11' - 5"

191
305
-

171
274
-

154
247
-

139
223
-

126
202
-

114
183
-

Attachment Pattern
2299 2276 2255
2107 2094 2082
2093 2080 2069
2080 2068 2057

2236
2071
2058
2047

2219
2061
2049
2038

2203
2052
2040
2030

2201
2055
2044
2034

2187
2047
2036
2027

Mno/= 38.0 kip-in/ft


Mno= 58.2 kip-in/ft

Vn/ = 3.02 kip/ft


Vn = 5.77 kip/ft

www.ascsd.com

TABLE OF CONTENTS

2WH-36 Composite Deck 3.3


5" Total Slab Depth
Light Weight Concrete (110 pcf)

Vertical Load Span (in)


ASD, W/
LRFD, W
L/360
Arc Spot Weld 1/2" Effective Dia
PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

6'-6"

7'-0"

18

6'-0"

6'-6"

16

185
296
-

167
268
-

152
243
-

138
221
-

Attachment Pattern
2403 2375 2349
2169 2152 2137
2152 2136 2122
2138 2123 2110

2326
2124
2109
2097

2305
2111
2097
2086

2285
2100
2086
2075

2284
2106
2093
2083

2267
2096
2083
2073

Mno/= 44.4 kip-in/ft


Mno= 67.9 kip-in/ft

7'-0"

7'-6"

8'-0"

8'-6"

9'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


2771 2740 2675 2619 2570 2526
2351 2352 2315 2283 2255 2230
2320 2324 2289 2258 2232 2208
2299 2304 2270 2241 2215 2193

6'-0"

6'-6"

36/4
2488
2208
2187
2173

251
402
-

226
362
-

204
327
-

185
296
-

165
270
165

146
246
146

Attachment Pattern
2481 2449 2419
2216 2197 2179
2197 2178 2162
2183 2165 2150

2393
2164
2147
2135

2368
2149
2133
2122

2346
2136
2121
2110

2347
2145
2130
2120

2327
2133
2119
2109

Mno/= 48.5 kip-in/ft


Mno= 74.2 kip-in/ft

Icr = 77.7 in4/ft


Iu = 130.5 in4/ft
7'-0"

7'-6"

8'-0"

8'-6"

9'-0"

36/4
2681
2319
2281
2280

Vn/ = 3.02 kip/ft


Vn = 6.04 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

ASD & LRFD - Superimposed Load, W (psf)


1007 860 737 638 557 490 434 387 346
1623 1376 1180 1021 892 785 695 619 554
LRFD - Diaphragm Shear, Sn (plf / ft)
3040 3010 2926 2852 2788 2732
2497 2510 2461 2418 2381 2349
2440 2457 2412 2372 2338 2308
2438 2455 2410 2371 2337 2307

Vn/ = 3.02 kip/ft


Vn = 6.04 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

ASD & LRFD - Superimposed Load, W (psf)


830 703 602 520 454 399 352 313 280
1328 1124 963 833 726 638 564 501 448
-

Concrete + Deck = 40.0 psf


(Icr+Iu)/2 = 113.8 in4/ft

304
498
304

264
449
264

231
407
231

203
370
203

180
337
180

160
308
160

Attachment Pattern
2680 2637 2599
2337 2312 2289
2301 2277 2256
2300 2277 2255

2564
2268
2236
2235

2531
2248
2218
2218

2502
2231
2202
2201

2508
2248
2220
2220

2482
2232
2205
2204

Mno/= 59.0 kip-in/ft


Mno= 90.2 kip-in/ft

Icr = 90.1 in4/ft


Iu = 137.6 in4/ft

Vn/ = 3.02 kip/ft


Vn = 6.04 kip/ft

LRFD - Diaphragm Shear, Sn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width

3/4" Welded Shear Studs


12 in o.c.
24 in o.c.
36 in o.c.

www.ascsd.com

6x6 W1.4xW1.4

As = 0.028 in2/ft
3350
3350
3350

6x6 W2.9xW2.9

As = 0.058 in2/ft
4700
4700
4700

6x6 W4.0xW4.0

As = 0.080 in2/ft
5690
5690
5170

4x4 W4xW4

As = 0.120 in2/ft
7490
7490
5170

4x4 W6xW6

As = 0.180 in2/ft
10190
7750
5170

Composite and Non-Composite Deck Catalog May 2014

ACUSTADEK

All Gages

205
327
-

D PANEL

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

36/4
2411
2164
2146
2132

227
364
-

C PANELS

ASD, W/
LRFD, W
L/360

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

Icr = 72.5 in4/ft


Iu = 127.7 in4/ft

Concrete + Deck = 39.3 psf


(Icr+Iu)/2 = 104.1 in4/ft
Vertical Load Span (in)

9'-0"

N PANELS

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

8'-6"

B PANELS

ASD, W/
LRFD, W
L/360

8'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


2663 2632 2575 2526 2483 2445
2293 2290 2258 2230 2205 2183
2265 2265 2234 2208 2184 2164
2244 2245 2216 2191 2168 2149

Concrete + Deck = 39.1 psf


(Icr+Iu)/2 = 100.1 in4/ft
Vertical Load Span (in)

7'-6"

ASD & LRFD - Superimposed Load, W (psf)


757 641 548 474 413 363 320 284 254
1211 1025 877 758 661 580 512 455 406
-

2W PANELS

19

6'-0"

3W PANELS

GA

Concrete Volume 1.125yd3/100ft2

GENERAL INFORMATION

103

TABLE OF CONTENTS

3.3 2WH-36 Composite Deck

5 14" Total Slab Depth


Light Weight Concrete (110 pcf)

Gage
22
21
20
GA

22

Concrete Volume 1.392yd3/100ft2


2 Hour Fire Rating

Single
8' - 4"
9' - 3"
9' - 7"

Maximum Unshored Span (in)


Triple
Gage
9' - 7"
19
10' - 5"
18
10' - 10"
16

Double
9' - 2"
10' - 1"
10' - 6"

Vertical Load Span (in)

6'-0"

6'-6"

ASD, W/
LRFD, W
L/360

587
939
-

495
793
-

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

7'-0"

ASD, W/
LRFD, W
L/360
21

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

36/4
2385
2220
2207
2195

Icr = 64.1 in4/ft


Iu = 137.7 in4/ft
7'-0"

7'-6"

8'-0"

8'-6"

153
245
-

138
220
-

124
198
-

112
179
-

101
162
-

Attachment Pattern
2376 2358 2341
2220 2209 2199
2207 2197 2188
2196 2187 2178

2326
2191
2180
2170

2312
2183
2173
2163

2299
2175
2166
2157

2295
2177
2167
2159

2284
2170
2161
2153

Mno/= 34.9 kip-in/ft


Mno= 53.3 kip-in/ft

661
1057
-

6'-0"

6'-6"

ASD, W/
LRFD, W
L/360

696
1114
-

589
942
-

36/4
2441
2252
2237
2224

Icr = 70.3 in4/ft


Iu = 140.7 in4/ft
7'-0"

7'-6"

8'-0"

8'-6"

9'-0"

36/4
2470
2268
2252
2239

Icr = 73.1 in4/ft


Iu = 142.2 in4/ft

Composite and Non-Composite Deck Catalog May 2014

Vn/ = 3.22 kip/ft


Vn = 4.82 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"


195
312
-

175
280
-

158
252
-

142
227
-

129
206
-

117
187
-

Attachment Pattern
2432 2411 2391
2252 2240 2229
2239 2227 2216
2226 2215 2205

2374
2218
2207
2196

2358
2209
2198
2188

2343
2201
2190
2180

2340
2203
2193
2183

2327
2196
2185
2177

Mno/= 39.0 kip-in/ft


Mno= 59.7 kip-in/ft

Vn/ = 3.22 kip/ft


Vn = 5.53 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

ASD & LRFD - Superimposed Load, W (psf)


503 435 378 332 292 259 231
805 695 605 530 468 415 370
-

LRFD - Diaphragm Shear, Sn (plf / ft)


2679 2650 2604 2564 2528 2498
2376 2370 2343 2321 2301 2283
2353 2348 2324 2302 2283 2267
2333 2330 2307 2286 2269 2253

Triple
12' - 2"
12' - 6"
13' - 2"

171
274
-

ASD & LRFD - Superimposed Load, W (psf)


558 477 412 358 314 277 245 218
894 764 659 573 502 443 392 349
-

LRFD - Diaphragm Shear, Sn (plf / ft)


2638 2610 2566 2529 2496 2467
2354 2347 2322 2301 2283 2266
2332 2327 2304 2284 2266 2251
2313 2309 2287 2268 2252 2237

9'-0"

Double
11' - 10"
12' - 8"
14' - 0"

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

6'-6"

Concrete + Deck = 41.0 psf


(Icr+Iu)/2 = 107.6 in4/ft

104

9'-0"

6'-0"

Vertical Load Span (in)

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

8'-6"

LRFD - Diaphragm Shear, Sn (plf / ft)


2558 2531 2494 2461 2433 2408
2310 2303 2281 2263 2247 2233
2291 2285 2265 2248 2233 2219
2273 2268 2249 2233 2219 2207

Concrete + Deck = 40.9 psf


(Icr+Iu)/2 = 105.5 in4/ft

20

8'-0"

ASD & LRFD - Superimposed Load, W (psf)


423 365 317 277 244 216 192
677 583 507 443 390 345 307
-

Concrete + Deck = 40.7 psf


(Icr+Iu)/2 = 100.9 in4/ft
Vertical Load Span (in)

7'-6"

Single
10' - 2"
10' - 6"
11' - 3"

207
331
-

186
297
-

167
267
-

151
242
-

137
219
-

124
199
-

Attachment Pattern
2461 2438 2417
2269 2256 2244
2255 2242 2231
2242 2230 2219

2398
2233
2220
2209

2381
2223
2211
2200

2365
2214
2202
2192

2363
2217
2206
2196

2349
2209
2198
2189

Mno/= 41.1 kip-in/ft


Mno= 62.8 kip-in/ft

Vn/ = 3.22 kip/ft


Vn = 5.92 kip/ft

www.ascsd.com

TABLE OF CONTENTS

2WH-36 Composite Deck 3.3


5 14" Total Slab Depth
Light Weight Concrete (110 pcf)

Concrete Volume 1.292yd3/100ft2


2 Hour Fire Rating

Vertical Load Span (in)


ASD, W/
LRFD, W
L/360
Arc Spot Weld 1/2" Effective Dia
PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

6'-6"

7'-0"

18

6'-0"

6'-6"

16

200
320
-

181
290
-

165
263
-

150
240
-

Attachment Pattern
2565 2537 2511
2331 2314 2299
2314 2298 2284
2300 2285 2272

2488
2286
2271
2259

2467
2273
2259
2248

2447
2262
2248
2237

2446
2268
2255
2245

2429
2258
2245
2235

Mno/= 48.0 kip-in/ft


Mno= 73.4 kip-in/ft

7'-0"

7'-6"

8'-0"

8'-6"

9'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


2933 2902 2837 2781 2732 2688
2513 2514 2477 2445 2417 2392
2482 2486 2451 2420 2394 2370
2461 2466 2432 2403 2377 2355

6'-0"

6'-6"

36/4
2650
2370
2349
2335

272
435
-

245
392
-

222
354
-

201
321
-

183
292
-

167
266
-

Attachment Pattern
2643 2611 2581
2378 2359 2341
2359 2340 2324
2345 2327 2312

2555
2326
2309
2297

2530
2311
2295
2284

2508
2298
2283
2272

2509
2307
2292
2282

2489
2295
2281
2271

Mno/= 52.4 kip-in/ft


Mno= 80.2 kip-in/ft

Icr = 88.6 in4/ft


Iu = 150.3 in4/ft
7'-0"

7'-6"

8'-0"

8'-6"

9'-0"

36/4
2843
2482
2443
2442

Vn/ = 3.22 kip/ft


Vn = 6.44 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

ASD & LRFD - Superimposed Load, W (psf)


1074 931 798 691 604 531 470 419 375
1757 1489 1277 1106 966 850 753 670 600
LRFD - Diaphragm Shear, Sn (plf / ft)
3202 3173 3088 3014 2950 2894
2659 2672 2623 2580 2543 2511
2602 2619 2574 2534 2500 2470
2600 2617 2572 2533 2499 2469

Vn/ = 3.22 kip/ft


Vn = 6.44 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

ASD & LRFD - Superimposed Load, W (psf)


897 760 651 563 491 431 381 339 303
1436 1216 1041 901 786 690 610 543 485
-

Concrete + Deck = 42.3 psf


(Icr+Iu)/2 = 130.6 in4/ft

337
539
-

303
487
303

265
441
265

233
401
233

207
366
207

184
334
184

Attachment Pattern
2842 2799 2761
2499 2474 2451
2463 2439 2418
2462 2439 2417

2726
2430
2398
2397

2693
2410
2380
2380

2664
2393
2364
2363

2670
2410
2382
2382

2644
2394
2367
2366

Mno/= 63.8 kip-in/ft


Mno= 97.6 kip-in/ft

Icr = 102.9 in4/ft


Iu = 158.3 in4/ft

Vn/ = 3.22 kip/ft


Vn = 6.44 kip/ft

LRFD - Diaphragm Shear, Sn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width

3/4" Welded Shear Studs


12 in o.c.
24 in o.c.
36 in o.c.

www.ascsd.com

6x6 W1.4xW1.4

As = 0.028 in2/ft
3540
3540
3540

6x6 W2.9xW2.9

As = 0.058 in2/ft
4890
4890
4890

6x6 W4.0xW4.0

As = 0.080 in2/ft
5880
5880
5170

4x4 W4xW4

As = 0.120 in2/ft
7680
7680
5170

4x4 W6xW6

As = 0.180 in2/ft
10380
7750
5170

Composite and Non-Composite Deck Catalog May 2014

ACUSTADEK

All Gages

222
355
-

D PANEL

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

36/4
2573
2326
2308
2294

246
394
-

C PANELS

ASD, W/
LRFD, W
L/360

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

Icr = 82.7 in4/ft


Iu = 147.1 in4/ft

Concrete + Deck = 41.7 psf


(Icr+Iu)/2 = 119.5 in4/ft
Vertical Load Span (in)

9'-0"

N PANELS

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

8'-6"

B PANELS

ASD, W/
LRFD, W
L/360

8'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


2825 2794 2737 2688 2645 2607
2455 2452 2420 2392 2367 2345
2427 2427 2396 2370 2346 2326
2406 2407 2378 2353 2331 2311

Concrete + Deck = 41.4 psf


(Icr+Iu)/2 = 114.9 in4/ft
Vertical Load Span (in)

7'-6"

ASD & LRFD - Superimposed Load, W (psf)


818 693 593 513 447 392 347 308 275
1310 1108 949 820 715 628 554 493 440
-

2W PANELS

19

6'-0"

3W PANELS

GA

GENERAL INFORMATION

105

TABLE OF CONTENTS

3.3 2WH-36 Composite Deck


6 316" Total Slab Depth
Light Weight Concrete (110 pcf)

Gage
22
21
20
GA

Concrete Volume 1.582yd3/100ft2


3 Hour Fire Rating

Single
7' - 9"
8' - 7"
9' - 0"
Vertical Load Span (in)
ASD, W/
LRFD, W
L/360

22

Maximum Unshored Span (in)


Triple
Gage
9' - 0"
19
9' - 9"
18
10' - 2"
16

Double
8' - 8"
9' - 5"
9' - 10"

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

6'-0"

6'-6"

755 638
1208 1021
-

7'-0"

ASD, W/
LRFD, W
L/360
21

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

ASD, W/
LRFD, W
L/360
20

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

6'-0"

6'-6"

9'-0"

36/4
2993
2828
2815
2803

Icr = 98.7 in4/ft


Iu = 224.1 in4/ft
7'-0"

7'-6"

8'-0"

8'-6"

9'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


3246 3217 3174 3137 3104 3075
2961 2955 2930 2909 2890 2874
2939 2934 2911 2891 2874 2858
2920 2917 2895 2876 2859 2845

6'-0"

6'-6"

36/4
3049
2859
2845
2832

Icr = 108.4 in4/ft


Iu = 228.6 in4/ft
7'-0"

7'-6"

8'-0"

8'-6"

9'-0"

36/4
3078
2875
2860
2847

Icr = 112.9 in4/ft


Iu = 230.8 in4/ft

Composite and Non-Composite Deck Catalog May 2014

Triple
11' - 5"
12' - 0"
12' - 7"

222
355
-

199
318
-

179
286
-

161
258
-

145
233
-

132
211
-

Attachment Pattern
2984 2965 2949
2827 2817 2807
2815 2805 2796
2804 2794 2786

2933
2798
2788
2778

2919
2790
2780
2771

2907
2783
2773
2764

2903
2784
2775
2766

2892
2778
2769
2760

Mno/= 44.7 kip-in/ft


Mno= 68.5 kip-in/ft

Vn/ = 3.78 kip/ft


Vn = 5.42 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"


253
405
-

227
363
-

205
327
-

185
296
-

167
268
-

152
243
-

Attachment Pattern
3040 3018 2999
2860 2848 2836
2846 2834 2824
2834 2823 2813

2981
2826
2814
2804

2965
2817
2805
2795

2951
2808
2797
2788

2947
2811
2800
2791

2935
2803
2793
2784

Mno/= 50.2 kip-in/ft


Mno= 76.8 kip-in/ft

Vn/ = 4.02 kip/ft


Vn = 6.13 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

ASD & LRFD - Superimposed Load, W (psf)


898 760 650 561 489 429 378 336 299
1437 1215 1040 898 782 686 605 537 479
LRFD - Diaphragm Shear, Sn (plf / ft)
3287 3257 3211 3171 3136 3105
2983 2977 2951 2928 2908 2891
2960 2956 2931 2910 2891 2875
2940 2938 2914 2894 2876 2861

Double
11' - 1"
11' - 11"
13' - 4"

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

ASD & LRFD - Superimposed Load, W (psf)


851 720 616 531 463 406 358 317 283
1362 1152 985 850 740 649 572 508 452
-

Concrete + Deck = 49.8 psf


(Icr+Iu)/2 = 171.8 in4/ft

106

8'-6"

LRFD - Diaphragm Shear, Sn (plf / ft)


3166 3139 3101 3069 3040 3015
2918 2910 2889 2871 2855 2840
2899 2892 2872 2855 2840 2827
2881 2876 2857 2841 2827 2814

Concrete + Deck = 49.7 psf


(Icr+Iu)/2 = 168.5 in4/ft
Vertical Load Span (in)

8'-0"

ASD & LRFD - Superimposed Load, W (psf)


545 470 409 358 315 279 248
872 752 654 572 504 446 397
-

Concrete + Deck = 49.5 psf


(Icr+Iu)/2 = 161.4 in4/ft
Vertical Load Span (in)

7'-6"

Single
9' - 7"
9' - 11"
10' - 7"

268
429
-

241
385
-

217
348
-

196
314
-

178
285
-

162
259
-

Attachment Pattern
3069 3046 3025
2877 2864 2851
2862 2850 2838
2850 2838 2827

3006
2840
2828
2817

2989
2830
2818
2808

2973
2821
2810
2800

2970
2825
2814
2804

2956
2816
2806
2797

Mno/= 52.8 kip-in/ft


Mno= 80.8 kip-in/ft

Vn/ = 4.02 kip/ft


Vn = 6.52 kip/ft

www.ascsd.com

TABLE OF CONTENTS

2WH-36 Composite Deck 3.3


6 316" Total Slab Depth
Light Weight Concrete (110 pcf)

Concrete Volume 1.582yd3/100ft2


3 Hour Fire Rating

Vertical Load Span (in)


ASD, W/
LRFD, W
L/360
Arc Spot Weld 1/2" Effective Dia
PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

6'-6"

7'-0"

18

6'-0"

6'-6"

16

261
417
-

236
378
-

215
344
-

196
313
-

Attachment Pattern
3173 3144 3119
2939 2922 2907
2921 2905 2891
2908 2893 2879

3095
2893
2878
2867

3074
2881
2866
2855

3055
2869
2856
2845

3054
2876
2862
2852

3036
2865
2853
2843

Mno/= 61.9 kip-in/ft


Mno= 94.6 kip-in/ft

7'-0"

7'-6"

8'-0"

8'-6"

9'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


3541 3509 3444 3388 3339 3296
3121 3122 3084 3052 3024 2999
3090 3093 3058 3028 3001 2978
3068 3073 3040 3011 2985 2963

6'-0"

6'-6"

36/4
3257
2977
2957
2943

354
566
-

319
510
-

288
462
-

262
419
-

238
381
-

218
348
-

Attachment Pattern
3251 3218 3189
2986 2966 2949
2966 2948 2932
2953 2935 2919

3162
2933
2917
2905

3138
2919
2903
2892

3116
2906
2890
2880

3116
2915
2900
2890

3097
2903
2889
2879

Mno/= 67.7 kip-in/ft


Mno= 103.6 kip-in/ft

Icr = 137.5 in4/ft


Iu = 243.1 in4/ft
7'-0"

7'-6"

8'-0"

8'-6"

9'-0"

36/4
3451
3089
3051
3050

Vn/ = 4.02 kip/ft


Vn = 8.04 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

ASD & LRFD - Superimposed Load, W (psf)


1341 1209 1037 898 785 691 612 546 489
2281 1934 1659 1438 1256 1106 980 873 782
LRFD - Diaphragm Shear, Sn (plf / ft)
3809 3780 3695 3622 3558 3501
3267 3279 3230 3188 3151 3118
3209 3226 3181 3142 3108 3078
3208 3225 3180 3141 3107 3077

Vn/ = 4.02 kip/ft


Vn = 7.59 kip/ft

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

ASD & LRFD - Superimposed Load, W (psf)


1161 984 843 729 636 559 495 440 394
1857 1574 1349 1167 1018 895 792 704 630
-

Concrete + Deck = 51.1 psf


(Icr+Iu)/2 = 207.8 in4/ft

440
703
-

397
635
-

360
576
-

328
524
-

299
478
-

274
438
-

Attachment Pattern
3450 3407 3368
3107 3081 3058
3071 3047 3025
3070 3046 3025

3333
3037
3006
3005

3301
3018
2988
2987

3272
3000
2972
2971

3278
3018
2990
2989

3252
3001
2975
2974

Mno/= 82.7 kip-in/ft


Mno= 126.5 kip-in/ft

Icr = 160.2 in4/ft


Iu = 255.4 in4/ft

Vn/ = 4.02 kip/ft


Vn = 8.04 kip/ft

LRFD - Diaphragm Shear, Sn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width

3/4" Welded Shear Studs


12 in o.c.
24 in o.c.
36 in o.c.

www.ascsd.com

6x6 W1.4xW1.4

As = 0.028 in2/ft
n/a
n/a
n/a

6x6 W2.9xW2.9

As = 0.058 in2/ft
5580
5580
5170

6x6 W4.0xW4.0

As = 0.080 in2/ft
6570
6570
5170

4x4 W4xW4

As = 0.120 in2/ft
8370
7750
5170

4x4 W6xW6

As = 0.180 in2/ft
11070
7750
5170

Composite and Non-Composite Deck Catalog May 2014

ACUSTADEK

All Gages

288
461
-

D PANEL

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

36/4
3181
2934
2915
2901

320
512
-

C PANELS

ASD, W/
LRFD, W
L/360

9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

Icr = 128.1 in4/ft


Iu = 238.3 in4/ft

Concrete + Deck = 50.4 psf


(Icr+Iu)/2 = 190.3 in4/ft
Vertical Load Span (in)

9'-0"

N PANELS

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"

8'-6"

B PANELS

ASD, W/
LRFD, W
L/360

8'-0"

LRFD - Diaphragm Shear, Sn (plf / ft)


3433 3402 3345 3296 3253 3215
3062 3060 3027 2999 2975 2953
3035 3034 3004 2977 2954 2933
3014 3015 2986 2960 2938 2919

Concrete + Deck = 50.2 psf


(Icr+Iu)/2 = 183.2 in4/ft
Vertical Load Span (in)

7'-6"

ASD & LRFD - Superimposed Load, W (psf)


1058 896 767 663 579 508 449 399 357
1693 1433 1228 1062 926 813 719 639 571
-

2W PANELS

19

6'-0"

3W PANELS

GA

GENERAL INFORMATION

107

TABLE OF CONTENTS

4.1 BH-36
2-3/8

3-5/8

1-3/4

1-1/2

2-3/8

3-5/8

1-1/2

1-3/4

1-3/4

36

36

BH-36 Profile

BHN-36 Profile

36/7 Attachment Patterns


B Series Embossment
Panel Properties

Gage

Weight

22
20
18
16

w
psf
1.70
2.03
2.68
3.35
Compression

Gage

Area

22
20
18
16

Ae
in2/ft
0.179
0.235
0.351
0.330

Base Metal
Thickness Yield Strength
t
in
0.029
0.035
0.047
0.059

Tensile
Strength

Area

Fu
ksi
65
65
65
65

Ag
in2/ft
0.514
0.615
0.814
1.012

Fy
ksi
50
50
50
50

Effective Section Modulus at Fy


Bending
Distance to
Section
N.A. from
Section
Modulus
Bottom
Modulus
Se+
yb
Sein3/ft
in
in3/ft
0.175
0.74
0.187
0.228
0.77
0.236
0.311
0.84
0.329
0.392
0.89
0.404

Gage
22
20
18
16

108

Condition

1"

End
772
Interior
1229
End
1081
Interior
1737
End
1834
Interior
2984
End
2771
Interior
4555
Web Crippling Constraints

960
1482
1336
2078
2239
3525
3351
5329

1223
1832
1690
2551
2802
4276
4158
6405
h=1.32"

Ig
in4/ft
0.200
0.240
0.313
0.383

yb
in
0.94
0.94
0.95
0.95

Sg
in3/ft
0.213
0.053
0.330
0.404

Radius of
Gyration
r
in
0.625
0.623
0.619
0.615

Effective Moment of Inertia for Deflection


Distance to
N.A. from
Bottom
yb
in
0.98
0.96
0.94
0.95

Reactions at Supports (plf) Based on Web Crippling


Allowable (Rn/)
2"
4"

Gross Section Properties


Distance to
Moment of
N.A. from
Section
Inertia
Bottom
Modulus

Moment of
Inertia

Moment of
Inertia

Ie+
in4/ft
0.157
0.197
0.287
0.377

I ein4/ft
0.197
0.237
0.313
0.383

Bearing Length of Webs


6"

1"

1223
1832
1690
2551
2802
4276
4158
6405

1180
1828
1655
2584
2805
4439
4240
6776
r=0.125"

Composite and Non-Composite Deck Catalog May 2014

Uniform Load Only


Id = (2Ie+Ig)/3
I+
in4/ft
0.171
0.211
0.296
0.379

Factored (Rn)
2"
4"
1469
2204
2045
3091
3425
5243
5127
7927

1871
2726
2586
3794
4287
6361
6361
9527

Iin4/ft
0.198
0.238
0.313
0.383

6"
1871
2726
2586
3794
4287
6361
6361
9527

=78.3

www.ascsd.com

TABLE OF CONTENTS

2-3/8

3-5/8

1-1/2

36/7

GENERAL INFORMATION

BHF-36 4.2

1-3/4

36/7 Attachment Patterns

36

BHF-36 Profile

Gage

Gage

Area
Ag
in2/ft
1.057
1.198
1.353
1.243
1.385
1.539
1.427
1.568
1.722

Effective Section Modulus at Fy


Bending
Distance to
N.A. from
Bottom
yb
in
0.43
0.39
0.36
0.53
0.48
0.44
0.61
0.56
0.52

Section
Modulus
Sein3/ft
0.360
0.410
0.432
0.443
0.531
0.559
0.510
0.637
0.681

Effective Moment of Inertia for Deflection


Distance to
N.A. from
Bottom
yb
in
0.81
0.73
0.62
0.84
0.77
0.68
0.87
0.81
0.73

Moment of
Inertia
Ie +
in4/ft
0.334
0.361
0.385
0.460
0.501
0.539
0.584
0.638
0.689

Moment of
Inertia
I ein4/ft
0.365
0.408
0.426
0.457
0.498
0.520
0.548
0.583
0.607

Uniform Load Only


Id = (2Ie+Ig)/3
I+
in4/ft
0.367
0.399
0.427
0.484
0.528
0.568
0.596
0.652
0.704

Iin4/ft
0.388
0.430
0.454
0.481
0.526
0.556
0.572
0.615
0.650

C PANELS

Section
Modulus
Se+
in3/ft
0.255
0.263
0.270
0.382
0.393
0.403
0.526
0.541
0.555

Radius of
Gyration
r
in
0.641
0.629
0.614
0.653
0.648
0.639
0.659
0.658
0.653

N PANELS

20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16

Area
Ae
in2/ft
0.604
0.706
0.868
0.790
0.894
1.058
0.988
1.094
1.260

Tensile
Strength
Fu
ksi
65
65
65
65
65
65
65
65
65

B PANELS

Compression

Base Metal
Thickness Yield Strength
t
Fy
in
ksi
0.0359 / 0.036
50
0.0359 / 0.047
50
0.0359 / 0.059
50
0.0478 / 0.036
50
0.0478 / 0.047
50
0.0478 / 0.059
50
0.0598 / 0.036
50
0.0598 / 0.047
50
0.0598 / 0.059
50

2W PANELS

20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16

Weight
w
psf
3.63
4.10
4.62
4.28
4.76
5.28
4.95
5.43
5.95

Gross Section Properties


Distance to
Moment of
N.A. from
Section
Inertia
Bottom
Modulus
Ig
yb
Sg
in4/ft
in
in3/ft
0.434
0.57
0.435
0.474
0.52
0.446
0.511
0.47
0.456
0.530
0.64
0.561
0.581
0.59
0.576
0.627
0.54
0.590
0.620
0.69
0.683
0.679
0.64
0.702
0.735
0.60
0.719

3W PANELS

Panel Properties

D PANEL
ACUSTADEK

www.ascsd.com

Composite and Non-Composite Deck Catalog May 2014

109

TABLE OF CONTENTS

4.3 BHF-36 Cellular Composite Deck


Normal Weight Concrete (145 pcf)
Maximum Unshored Spans

BHF-36 Cellular Shoring Table


Total Slab Depth
(in)

Volume
cy/100sf

3 1/2

0.776

4 1/2

1.085

5
1 Hour
Fire Rating

1.239

6
2 Hour
Fire Rating

1.548

6 3/4
3 Hour
Fire Rating

1.780

Gage
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16

145 pcf Normal Weight Concrete


Maximum Unshored Span
Slab and Deck
psf
Single
Double
34.0
8' - 5"
10' - 9"
34.5
8' - 7"
10' - 11"
35.0
8' - 8"
11' - 0"
34.7
10' - 5"
12' - 5"
35.2
10' - 8"
13' - 3"
35.7
10' - 11"
13' - 5"
35.4
11' - 1"
13' - 3"
35.8
11' - 4"
13' - 11"
36.3
11' - 6"
14' - 1"
46.1
7' - 7"
9' - 9"
46.6
7' - 9"
9' - 11"
47.1
7' - 10"
10' - 0"
46.8
9' - 6"
11' - 3"
47.2
9' - 9"
12' - 1"
47.8
9' - 11"
12' - 2"
47.4
10' - 1"
12' - 0"
47.9
10' - 5"
13' - 0"
48.4
10' - 7"
13' - 2"
52.1
7' - 3"
9' - 5"
52.6
7' - 5"
9' - 6"
53.1
7' - 6"
9' - 7"
52.8
9' - 1"
10' - 10"
53.3
9' - 4"
11' - 7"
53.8
9' - 7"
11' - 8"
53.5
9' - 9"
11' - 6"
54.0
10' - 0"
12' - 8"
54.5
10' - 3"
12' - 10"
64.2
6' - 9"
8' - 9"
64.7
6' - 10"
8' - 10"
65.2
6' - 11"
8' - 11"
64.9
8' - 7"
10' - 0"
65.4
8' - 9"
10' - 9"
65.9
8' - 10"
10' - 10"
65.6
9' - 2"
10' - 9"
66.0
9' - 5"
11' - 11"
66.6
9' - 7"
12' - 2"
73.3
6' - 5"
8' - 4"
73.8
6' - 6"
8' - 5"
74.3
6' - 8"
8' - 6"
73.9
8' - 2"
9' - 7"
74.4
8' - 4"
10' - 3"
74.9
8' - 5"
10' - 4"
74.6
8' - 9"
10' - 3"
75.1
9' - 0"
11' - 5"
75.6
9' - 3"
11' - 9"

Triple
9' - 9"
9' - 10"
10' - 0"
11' - 11"
12' - 0"
12' - 2"
12' - 11"
13' - 1"
13' - 3"
8' - 10"
9' - 0"
9' - 1"
10' - 10"
10' - 11"
11' - 0"
12' - 1"
12' - 3"
12' - 4"
8' - 6"
8' - 7"
8' - 8"
10' - 4"
10' - 6"
10' - 7"
11' - 9"
11' - 11"
12' - 0"
7' - 11"
8' - 0"
8' - 1"
9' - 8"
9' - 9"
9' - 10"
11' - 1"
11' - 4"
11' - 6"
7' - 6"
7' - 7"
7' - 8"
9' - 2"
9' - 3"
9' - 4"
10' - 8"
10' - 10"
10' - 11"

Shaded area the span is governed by maximum deck panel length of 40 feet; 20 feet for double span, 13 feet 4 inches for triple span.

110

Composite and Non-Composite Deck Catalog May 2014

www.ascsd.com

TABLE OF CONTENTS

BHF-36 Cellular Composite Deck 4.3


Light Weight Concrete (110 pcf)
Maximum Unshored Spans

Volume
cy/100sf

3 1/2

0.776

1 Hour
Fire Rating

1.085

2 Hour
Fire Rating

1.162

3 Hour
Fire Rating

1.452

D PANEL

5 11/16

C PANELS

4 3/4

N PANELS

4 1/2

0.931

Triple
10' - 7"
10' - 9"
10' - 10"
12' - 11"
13' - 1"
13' - 2"
13' - 4"
13' - 4"
13' - 4"
10' - 1"
10' - 3"
10' - 4"
12' - 4"
12' - 6"
12' - 7"
13' - 3"
13' - 4"
13' - 4"
9' - 8"
9' - 10"
9' - 11"
11' - 10"
11' - 11"
12' - 1"
12' - 10"
13' - 0"
13' - 2"
9' - 6"
9' - 7"
9' - 8"
11' - 7"
11' - 8"
11' - 10"
12' - 8"
12' - 10"
13' - 0"
8' - 11"
9' - 0"
9' - 1"
10' - 10"
10' - 11"
11' - 1"
12' - 1"
12' - 3"
12' - 5"

B PANELS

ACUSTADEK

Gage
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16

110 pcf Light Weight Concrete


Maximum Unshored Span
Slab and Deck
psf
Single
Double
26.7
9' - 3"
11' - 9"
27.2
9' - 4"
11' - 10"
27.7
9' - 6"
11' - 11"
27.3
11' - 3"
13' - 6"
27.8
11' - 6"
14' - 4"
28.3
11' - 8"
14' - 5"
28.0
11' - 10"
14' - 5"
28.5
12' - 1"
14' - 9"
29.0
12' - 3"
14' - 11"
31.3
8' - 9"
11' - 2"
31.7
8' - 11"
11' - 4"
32.3
9' - 0"
11' - 5"
31.9
10' - 9"
12' - 10"
32.4
11' - 0"
13' - 9"
32.9
11' - 3"
13' - 11"
32.6
11' - 5"
13' - 9"
33.1
11' - 8"
14' - 3"
33.6
11' - 10"
14' - 5"
35.9
8' - 4"
10' - 8"
36.3
8' - 6"
10' - 10"
36.8
8' - 7"
10' - 11"
36.5
10' - 4"
12' - 3"
37.0
10' - 7"
13' - 2"
37.5
10' - 10"
13' - 4"
37.2
11' - 0"
13' - 2"
37.7
11' - 3"
13' - 10"
38.2
11' - 6"
14' - 0"
38.1
8' - 2"
10' - 6"
38.6
8' - 4"
10' - 7"
39.1
8' - 5"
10' - 8"
38.8
10' - 2"
12' - 1"
39.3
10' - 5"
12' - 11"
39.8
10' - 7"
13' - 0"
39.5
10' - 10"
12' - 10"
39.9
11' - 1"
13' - 8"
40.5
11' - 4"
13' - 10"
46.7
7' - 7"
9' - 10"
47.2
7' - 9"
9' - 11"
47.7
7' - 10"
10' - 0"
47.4
9' - 6"
11' - 3"
47.9
9' - 9"
12' - 1"
48.4
10' - 0"
12' - 2"
48.1
10' - 2"
12' - 1"
48.5
10' - 5"
13' - 0"
49.1
10' - 8"
13' - 2"

2W PANELS

Total Slab Depth


(in)

3W PANELS

BHF-36 Cellular Shoring Table

Shaded area the span is governed by maximum deck panel length of 40 feet; 20 feet for double span, 13 feet 4 inches for triple span.

www.ascsd.com

GENERAL INFORMATION

Composite and Non-Composite Deck Catalog May 2014

111

TABLE OF CONTENTS

4.4 BH-36 Composite Deck

3 12" Total Slab Depth


Normal Weight Concrete (145 pcf)

Concrete Volume 0.776yd3/100ft2

Gage
22
20

GA

22

Single
6' - 7"
7' - 10"

4'-0"

4'-6"

ASD, W/
LRFD, W
L/360

831
1329
-

651
1042
-

2809
2415
2384
2356
32.7
26.57

2712
2361
2334
2309
psf
in4/ft

4'-0"

4'-6"

Single
8' - 11"
9' - 7"

Double
10' - 6"
11' - 10"

Triple
11' - 2"
11' - 9"

5'-6"

6'-0"

6'-6"

7'-0"

7'-6"

8'-0"

8'-6"

9'-0"

9'-6"

523
836
-

428
684
-

356
569
-

299
479
-

255
408
-

219
350
-

189
303
-

165
264
-

144
231
-

127
203
-

112
180
-

2634
2318
2294
2271

2570
2283
2261
2241
Icr =
Iu =

2517 2489
2254 2246
2234 2227
2215 2210
17.4 in4/ft
35.7 in4/ft

2449
2223
2206
2190

2414
2204
2188
2173

2384
2187
2172
2158
Mno/=
Mno=

2358 2334
2172 2159
2158 2145
2144 2133
21.5 kip-in/ft
32.8 kip-in/ft

2324
2158
2145
2133

5'-0" 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0"


ASD & LRFD - Superimposed Load, W (psf)
442
372 317 273 236 206 181 159 141 125
111
ASD, W/
707
596 507 436 378 329 289 255 225 200 178
LRFD, W
L/360
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
2997 2878 2783 2705 2640 2609 2560 2518 2481 2448 2419
PAF Base Steel .25"
2516 2450 2398 2355 2319 2313 2285 2261 2240 2222 2206
PAF Base Steel 0.109"
2479 2418 2369 2328 2295 2290 2264 2242 2222 2205 2189
#12 Screw Base Steel .034"
2448 2390 2344 2306 2274 2271 2247 2225 2207 2190 2176
Concrete + Deck = 33.0 psf
Icr = 19.8 in4/ft
Mno/= 25.1 kip-in/ft
(Icr+Iu)/2 = 28.33 in4/ft
Iu = 36.9 in4/ft
Mno= 38.4 kip-in/ft

9'-6"

2305
2147
2135
2123
Vn/ =
Vn =

100
159
-

89
143
-

2410
2207
2192
2179

9'-6"

2385
2193
2178
2166
Vn/ =
Vn =

171
315
171

146
281
146

2591
2314
2293
2279

9'-6"

2558
2294
2275
2261
Vn/ =
Vn =

186
384
186

159
343
159

2791
2434
2395
2407

2747
2407
2370
2383
Vn/ =
Vn =

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"
Concrete + Deck =
(Icr+Iu)/2 =

ASD & LRFD - Superimposed Load, W (psf)

LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern

5'-0" 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0"


ASD & LRFD - Superimposed Load, W (psf)
951
845 760 638 532 450 384 331 286 238 201
ASD, W/
1426 1267 1141 1021 851 719 615 530 461 404 356
LRFD, W
L/360
286 238 201
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
3384 3221 3091 2984 2895 2861 2794 2735 2684 2639 2598
PAF Base Steel .25"
2725 2635 2563 2504 2455 2456 2417 2384 2354 2328 2305
PAF Base Steel 0.109"
2677 2592 2525 2469 2423 2426 2390 2358 2330 2306 2284
#12 Screw Base Steel .034"
2644 2563 2498 2445 2401 2406 2370 2340 2314 2290 2269
Concrete + Deck = 33.6 psf
Icr = 23.6 in4/ft
Mno/= 31.5 kip-in/ft
4
(Icr+Iu)/2 = 31.31 in /ft
Iu = 39.0 in4/ft
Mno= 48.1 kip-in/ft
Vertical Load Span (in)

4'-0"

4'-0"

4'-6"

4'-6"

5'-0" 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0"


ASD & LRFD - Superimposed Load, W (psf)
951 845 760 691 634 542 464 377
311
259 218
ASD, W/
1426 1267 1141 1037 951 867 742 641 558 490 433
LRFD, W
L/360
377
311
259 218
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
3798 3588 3419 3281 3166 3135 3047 2971 2904 2845 2793
PAF Base Steel .25"
2949 2833 2740 2664 2600 2613 2562 2518 2480 2446 2416
PAF Base Steel 0.109"
2857 2751 2666 2597 2539 2556 2509 2469 2434 2402 2375
#12 Screw Base Steel .034"
2870 2764 2679 2609 2551 2568 2522 2481 2446 2415 2387
Concrete + Deck = 34.3 psf
Icr = 27.0 in4/ft
Mno/= 37.6 kip-in/ft
(Icr+Iu)/2 = 34.04 in4/ft
Iu = 41.0 in4/ft
Mno= 57.6 kip-in/ft

10'-0" 10'-6" 11'-0"


100
159
-

89
142
-

2287 2271
2137 2127
2125 2116
2114 2106
1.90 kip/ft
2.85 kip/ft

10'-0" 10'-6" 11'-0"


80
128
-

72
115
-

2364 2344
2180 2169
2166 2156
2155 2144
1.90 kip/ft
2.85 kip/ft

10'-0" 10'-6" 11'-0"


126
251
126

110
225
110

2527 2499
2276 2259
2257 2242
2245 2230
1.90 kip/ft
2.85 kip/ft

10'-0" 10'-6" 11'-0"


137
307
137

120
276
120

2707 2670
2383 2361
2348 2328
2360 2340
1.90 kip/ft
2.85 kip/ft

All Gages

16

Gage
18
16

5'-0"

Vertical Load Span (in)

18

Triple
7' - 9"
9' - 3"

Vertical Load Span (in)

Vertical Load Span (in)

20

Maximum Unshored Span (in)

Double
6' - 10"
8' - 6"

LRFD - Diaphragm Shear, Sn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4
6x6 W2.9xW2.9
6x6 W4.0xW4.0
4x4 W4xW4
4x4 W6xW6
3/4" Welded Shear Studs
As = 0.028 in2/ft
As = 0.058 in2/ft
As = 0.080 in2/ft
As = 0.120 in2/ft
As = 0.180 in2/ft
6 in o.c.
3200
4550
5540
7340
10040
12 in o.c.
3200
4550
5540
7340
10040
18 in o.c.
3200
4550
5540
7340
8790

112

Composite and Non-Composite Deck Catalog May 2014

www.ascsd.com

TABLE OF CONTENTS

BH-36 Composite Deck 4.4


4" Total Slab Depth
Normal Weight Concrete (145 pcf)



Gage
22
20

22

4'-0"

4'-6"

ASD, W/
LRFD, W
L/360

1051
1681
-

824
1319
-

Double
10' - 1"
11' - 3"

Triple
10' - 7"
11' - 4"

6'-6"

7'-0"

7'-6"

8'-0"

8'-6"

9'-0"

9'-6"

662
1059
-

542
867
-

451
721
-

380
608
-

324
518
-

278
445
-

241
385
-

210
336
-

184
295
-

162
260
-

144
230
-

3402
2953
2918
2886

3313
2905
2873
2844
Icr =
Iu =

3238 3192
2865 2847
2836 2821
2809 2796
25.4 in4/ft
53.4 in4/ft

3137
2817
2792
2769

3090
2791
2768
2746

3048
2768
2746
2726
Mno/=
Mno=

3011 2979
2747 2729
2727 2710
2708 2692
27.1 kip-in/ft
41.5 kip-in/ft

2961
2725
2706
2689

5'-0" 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0"


ASD & LRFD - Superimposed Load, W (psf)
1132 969 780 639 532 449 383 330 287 251 220
ASD, W/
1698 1509 1248 1023 852 719 613 528 459 401 353
LRFD, W
L/360
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
3905 3739 3607 3499 3409 3356 3289 3231 3180 3135 3095
PAF Base Steel .25"
3221 3132 3061 3002 2953 2936 2899 2867 2839 2814 2792
PAF Base Steel 0.109"
3170 3086 3019 2964 2919 2904 2869 2839 2813 2789 2769
#12 Screw Base Steel .034"
3126 3047 2984 2932 2889 2877 2844 2816 2791 2769 2749
Concrete + Deck = 39.2 psf
Icr = 28.8 in4/ft
Mno/= 31.7 kip-in/ft
(Icr+Iu)/2 = 42 in4/ft
Iu = 55.2 in4/ft
Mno= 48.5 kip-in/ft

9'-6"

2934
2710
2692
2676
Vn/ =
Vn =

195
312
-

173
277
-

3076
2788
2766
2748

9'-6"

3043
2770
2749
2731
Vn/ =
Vn =

253
405
-

217
361
217

3318
2923
2895
2875

9'-6"

3272
2897
2870
2851
Vn/ =
Vn =

275
494
275

236
441
236

3580
3072
3016
3029

3520
3038
2985
2998
Vn/ =
Vn =

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"
Concrete + Deck =
(Icr+Iu)/2 =

LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern

3646 3510
3086 3012
3042 2974
3002 2938
38.8 psf
39.4 in4/ft
4'-0"

4'-0"

4'-6"

2909 2887
2696 2683
2679 2668
2664 2653
2.26 kip/ft
3.40 kip/ft

10'-0" 10'-6" 11'-0"


154
247
-

138
220
-

3013 2986
2753 2738
2733 2719
2716 2703
2.26 kip/ft
3.40 kip/ft

10'-0" 10'-6" 11'-0"


187
323
187

163
290
163

3231 3193
2874 2853
2848 2828
2830 2811
2.26 kip/ft
3.40 kip/ft

10'-0" 10'-6" 11'-0"


204
396
204

177
356
177

3467 3418
3007 2979
2957 2931
2969 2944
2.26 kip/ft
3.40 kip/ft

www.ascsd.com

Composite and Non-Composite Deck Catalog May 2014

113

ACUSTADEK

LRFD - Diaphragm Shear, Sn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4
6x6 W2.9xW2.9
6x6 W4.0xW4.0
4x4 W4xW4
4x4 W6xW6
3/4" Welded Shear Studs
As = 0.028 in2/ft
As = 0.058 in2/ft
As = 0.080 in2/ft
As = 0.120 in2/ft
As = 0.180 in2/ft
6 in o.c.
3690
5040
6030
7830
10530
12 in o.c.
3690
5040
6030
7830
10530
18 in o.c.
3690
5040
6030
7830
8790

D PANEL

5'-0" 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0"


ASD & LRFD - Superimposed Load, W (psf)
1132 1006 906 823 755 694 594 514 448 384 323
ASD, W/
1698 1509 1358 1235 1132 1045 951 822 717 629 556
LRFD, W
L/360
384 323
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
4996 4707 4475 4286 4128 4061 3942 3839 3748 3669 3598
PAF Base Steel .25"
3789 3634 3510 3409 3324 3319 3252 3195 3145 3101 3062
PAF Base Steel 0.109"
3658 3518 3405 3313 3237 3238 3178 3125 3080 3039 3003
#12 Screw Base Steel .034"
3672 3531 3418 3326 3249 3251 3190 3138 3092 3052 3016
Concrete + Deck = 40.4 psf
Icr = 39.8 in4/ft
Mno/= 48.0 kip-in/ft
(Icr+Iu)/2 = 50.4 in4/ft
Iu = 61.1 in4/ft
Mno= 73.5 kip-in/ft

114
182
-

C PANELS

4'-6"

128
204
-

N PANELS

5'-0" 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0"


ASD & LRFD - Superimposed Load, W (psf)
1132 1006 906 814 679 574 491 424 369 323 285
ASD, W/
1698 1509 1358 1235 1087 919 786 678 590 517 456
LRFD, W
L/360
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
4436 4210 4029 3882 3759 3697 3605 3525 3455 3393 3338
PAF Base Steel .25"
3499 3377 3280 3200 3134 3120 3069 3025 2986 2952 2922
PAF Base Steel 0.109"
3430 3316 3225 3151 3089 3078 3030 2989 2952 2920 2891
#12 Screw Base Steel .034"
3383 3274 3187 3116 3057 3049 3003 2963 2928 2898 2870
Concrete + Deck = 39.8 psf
Icr = 34.6 in4/ft
Mno/= 40.0 kip-in/ft
4
(Icr+Iu)/2 = 46.4 in /ft
Iu = 58.2 in4/ft
Mno= 61.3 kip-in/ft
4'-0"

4'-6"

10'-0" 10'-6" 11'-0"

B PANELS

6'-0"

ASD & LRFD - Superimposed Load, W (psf)

2W PANELS

All Gages

Single
8' - 5"
9' - 2"

5'-6"

Vertical Load Span (in)

16

Gage
18
16

5'-0"

Vertical Load Span (in)

18

Triple
7' - 5"
8' - 9"

Vertical Load Span (in)

Vertical Load Span (in)

20

Maximum Unshored Span (in)

Double
6' - 8"
8' - 1"

3W PANELS

GA

Single
6' - 3"
7' - 5"

Concrete Volume 0.931yd3/100ft2

GENERAL INFORMATION

TABLE OF CONTENTS

4.4 BH-36 Composite Deck

4 12" Total Slab Depth


Normal Weight Concrete (145 pcf)

Concrete Volume 1.085yd3/100ft2

Gage
22
20

GA

22

Single
6' - 0"
7' - 1"

4'-0"

4'-6"

ASD, W/
LRFD, W
L/360

1282
1987
-

1006
1609
-

3790
3396
3365
3337
45.0
55.87

3693
3342
3315
3290
psf
in4/ft

4'-0"

4'-6"

Single
8' - 1"
8' - 9"

Double
9' - 7"
10' - 9"

Triple
10' - 1"
10' - 10"

5'-6"

6'-0"

6'-6"

7'-0"

7'-6"

8'-0"

8'-6"

9'-0"

9'-6"

808
1293
-

662
1059
-

551
882
-

465
743
-

396
633
-

341
545
-

295
472
-

258
412
-

226
362
-

200
319
-

177
283
-

3615
3299
3275
3252

3551
3264
3242
3221
Icr =
Iu =

3498 3469
3235 3227
3215 3208
3196 3191
35.2 in4/ft
76.6 in4/ft

3430
3204
3187
3171

3395
3185
3169
3154

3365
3168
3153
3139
Mno/=
Mno=

3339 3315
3153 3140
3139 3126
3125 3114
33.0 kip-in/ft
50.5 kip-in/ft

3305
3139
3126
3114

5'-0" 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0"


ASD & LRFD - Superimposed Load, W (psf)
1325 1178 954 782 652 550 470 405 352 308 271
ASD, W/
1987 1766 1526 1251 1043 881 752 648 563 492 433
LRFD, W
L/360
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
3977 3859 3763 3686 3621 3590 3541 3499 3462 3429 3400
PAF Base Steel .25"
3497 3431 3379 3336 3300 3294 3266 3242 3221 3203 3186
PAF Base Steel 0.109"
3460 3399 3349 3309 3276 3271 3245 3223 3203 3186 3170
#12 Screw Base Steel .034"
3429 3371 3325 3287 3255 3252 3228 3206 3188 3171 3156
Concrete + Deck = 45.3 psf
Icr = 40.0 in4/ft
Mno/= 38.7 kip-in/ft
(Icr+Iu)/2 = 59.46 in4/ft
Iu = 78.9 in4/ft
Mno= 59.3 kip-in/ft

9'-6"

3286
3128
3115
3104
Vn/ =
Vn =

240
383
-

213
341
-

3390
3188
3173
3160

9'-6"

3366
3174
3159
3147
Vn/ =
Vn =

312
500
-

278
446
-

3572
3295
3274
3260

9'-6"

3538
3275
3255
3242
Vn/ =
Vn =

382
612
-

334
547
334

3772
3415
3376
3388

3728
3388
3351
3363
Vn/ =
Vn =

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"
Concrete + Deck =
(Icr+Iu)/2 =

ASD & LRFD - Superimposed Load, W (psf)

LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern

5'-0" 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0"


ASD & LRFD - Superimposed Load, W (psf)
1325 1178 1060 963 835 706 604 522 455 399 352
ASD, W/
1987 1766 1590 1445 1325 1130 967 835 727 638 563
LRFD, W
L/360
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
4365 4202 4071 3964 3875 3842 3775 3716 3665 3620 3579
PAF Base Steel .25"
3706 3616 3544 3485 3436 3436 3398 3364 3335 3309 3286
PAF Base Steel 0.109"
3658 3573 3505 3450 3404 3407 3370 3339 3311 3287 3265
#12 Screw Base Steel .034"
3625 3544 3479 3426 3382 3386 3351 3321 3294 3271 3250
Concrete + Deck = 46.0 psf
Icr = 48.2 in4/ft
Mno/= 49.1 kip-in/ft
4
(Icr+Iu)/2 = 65.67 in /ft
Iu = 83.1 in4/ft
Mno= 75.1 kip-in/ft
Vertical Load Span (in)

4'-0"

4'-0"

4'-6"

4'-6"

5'-0" 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0"


ASD & LRFD - Superimposed Load, W (psf)
1325 1178 1060 963 883 815 734 635 553 486 430
ASD, W/
1987 1766 1590 1445 1325 1223 1136 1015 886 778 688
LRFD, W
L/360
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
4779 4568 4400 4262 4147 4116 4028 3952 3885 3826 3774
PAF Base Steel .25"
3930 3814 3721 3645 3581 3594 3543 3499 3461 3427 3397
PAF Base Steel 0.109"
3838 3732 3647 3578 3520 3537 3490 3450 3414 3383 3356
#12 Screw Base Steel .034"
3851 3744 3660 3590 3532 3549 3503 3462 3427 3396 3368
Concrete + Deck = 46.6 psf
Icr = 55.6 in4/ft
Mno/= 59.1 kip-in/ft
(Icr+Iu)/2 = 71.36 in4/ft
Iu = 87.1 in4/ft
Mno= 90.4 kip-in/ft

10'-0" 10'-6" 11'-0"


157
252
-

140
224
-

3268 3252
3118 3108
3106 3097
3095 3087
2.65 kip/ft
3.97 kip/ft

10'-0" 10'-6" 11'-0"


190
304
-

170
272
-

3344 3325
3161 3150
3147 3136
3136 3125
2.65 kip/ft
3.97 kip/ft

10'-0" 10'-6" 11'-0"


249
399
-

224
359
-

3508 3480
3257 3240
3238 3223
3226 3211
2.65 kip/ft
3.97 kip/ft

10'-0" 10'-6" 11'-0"


288
491
288

251
442
251

3688 3651
3364 3342
3329 3309
3341 3321
2.65 kip/ft
3.97 kip/ft

All Gages

16

Gage
18
16

5'-0"

Vertical Load Span (in)

18

Triple
7' - 1"
8' - 4"

Vertical Load Span (in)

Vertical Load Span (in)

20

Maximum Unshored Span (in)

Double
6' - 5"
7' - 10"

LRFD - Diaphragm Shear, Sn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4
6x6 W2.9xW2.9
6x6 W4.0xW4.0
4x4 W4xW4
4x4 W6xW6
3/4" Welded Shear Studs
As = 0.028 in2/ft
As = 0.058 in2/ft
As = 0.080 in2/ft
As = 0.120 in2/ft
As = 0.180 in2/ft
6 in o.c.
4180
5530
6520
8320
11020
12 in o.c.
4180
5530
6520
8320
11020
18 in o.c.
4180
5530
6520
8320
8790

114

Composite and Non-Composite Deck Catalog May 2014

www.ascsd.com

TABLE OF CONTENTS

BH-36 Composite Deck 4.4


5" Total Slab Depth
Normal Weight Concrete (145 pcf)

Concrete Volume 1.239yd3/100ft2


1 Hour Fire Rating


Gage
22
20

22

4'-6"

ASD, W/
LRFD, W
L/360

1521
2294
-

1194
1910
-

4281
3886
3856
3827
51.2
76.31

4183
3833
3805
3780
psf
in4/ft

4'-0"

4'-6"

Double
9' - 3"
10' - 4"

Triple
9' - 8"
10' - 5"

5'-6"

6'-0"

6'-6"

7'-0"

7'-6"

8'-0"

8'-6"

9'-0"

9'-6"

960
1535
-

786
1258
-

655
1047
-

552
883
-

471
753
-

405
648
-

351
562
-

307
491
-

270
431
-

238
381
-

211
338
-

4105
3790
3765
3743

4042
3755
3732
3712
Icr =
Iu =

3988
3725
3705
3686
46.8
105.8

3960
3717
3698
3681
in4/ft
in4/ft

3920
3695
3677
3661

3886
3675
3659
3644

3856
3658
3643
3629
Mno/=
Mno=

3829 3805
3643 3630
3629 3616
3616 3604
39.1 kip-in/ft
59.9 kip-in/ft

3796
3629
3617
3605

5'-0" 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0"


ASD & LRFD - Superimposed Load, W (psf)
1529 1359 1134 930 775 655 559 482 419 367 323
ASD, W/
2294 2039 1814 1488 1241 1048 895 772 671 587 517
LRFD, W
L/360
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
4468 4349 4254 4176 4111 4080 4031 3989 3952 3920 3891
PAF Base Steel .25"
3987 3922 3869 3826 3791 3784 3757 3733 3712 3693 3677
PAF Base Steel 0.109"
3950 3889 3840 3800 3766 3762 3736 3713 3693 3676 3661
#12 Screw Base Steel .034"
3920 3862 3815 3777 3746 3743 3718 3697 3678 3662 3647
Concrete + Deck = 51.5 psf
Icr = 53.4 in4/ft
Mno/= 46.0 kip-in/ft
(Icr+Iu)/2 = 81.12 in4/ft
Iu = 108.9 in4/ft
Mno= 70.3 kip-in/ft

9'-6"

3776
3618
3606
3595
Vn/ =
Vn =

286
458
-

254
407
-

3881
3678
3663
3650

9'-6"

3857
3664
3650
3637
Vn/ =
Vn =

374
599
-

334
534
-

4063
3785
3765
3751

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"
Concrete + Deck =
(Icr+Iu)/2 =

ASD & LRFD - Superimposed Load, W (psf)

LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern

4'-0"

3758 3742
3608 3599
3596 3588
3586 3577
3.06 kip/ft
4.59 kip/ft

10'-0" 10'-6" 11'-0"


227
363
-

204
326
-

3835 3815
3652 3640
3638 3627
3626 3616
3.06 kip/ft
4.59 kip/ft

10'-0" 10'-6" 11'-0"

9'-0"

9'-6"

4029
3765
3746
3732
Vn/ =
Vn =

516
826
-

459
734
-

410
657
-

4264
3887
3846
3858
kip-in/ft
kip-in/ft

4263
3905
3866
3879

4218
3879
3842
3854
Vn/ =
Vn =

299
479
-

269
431
-

3998 3970
3747 3731
3729 3713
3716 3701
3.06 kip/ft
4.59 kip/ft

10'-0" 10'-6" 11'-0"


369
590
-

332
532
-

4178 4142
3855 3833
3819 3799
3832 3811
3.06 kip/ft
4.59 kip/ft

www.ascsd.com

Composite and Non-Composite Deck Catalog May 2014

115

ACUSTADEK

LRFD - Diaphragm Shear, Sn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4
6x6 W2.9xW2.9
6x6 W4.0xW4.0
4x4 W4xW4
4x4 W6xW6
3/4" Welded Shear Studs
As = 0.028 in2/ft
As = 0.058 in2/ft
As = 0.080 in2/ft
As = 0.120 in2/ft
As = 0.180 in2/ft
6 in o.c.
n/a
6030
7020
8820
11520
12 in o.c.
n/a
6030
7020
8820
11520
18 in o.c.
n/a
6030
7020
8790
8790

D PANEL

5'-0" 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6"


ASD & LRFD - Superimposed Load, W (psf)
1529 1359 1223 1112 1019 941 874 760 664 583
ASD, W/
2294 2039 1835 1668 1529 1411 1311 1217 1062 933
LRFD, W
L/360
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
5269 5059 4890 4753 4638 4607 4519 4442 4376 4317
PAF Base Steel .25"
4420 4304 4211 4135 4072 4084 4033 3989 3951 3917
PAF Base Steel 0.109"
4328 4222 4137 4068 4010 4027 3981 3940 3905 3874
#12 Screw Base Steel .034"
4341 4235 4150 4081 4023 4040 3993 3953 3917 3886
Concrete + Deck = 52.8 psf
Icr = 74.7 in4/ft
Mno/= 70.6
(Icr+Iu)/2 = 97.25 in4/ft
Iu = 119.8 in4/ft
Mno= 108.0

168
268
-

C PANELS

4'-6"

188
301
-

N PANELS

5'-0" 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0"


ASD & LRFD - Superimposed Load, W (psf)
1529 1359 1223 1112 997 844 722 624 544 477 421
ASD, W/
2294 2039 1835 1668 1529 1350 1155 998 870 763 674
LRFD, W
L/360
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
4856 4692 4562 4455 4366 4333 4265 4206 4155 4110 4070
PAF Base Steel .25"
4196 4106 4034 3975 3926 3927 3888 3855 3826 3800 3777
PAF Base Steel 0.109"
4148 4064 3996 3940 3894 3897 3861 3829 3801 3777 3755
#12 Screw Base Steel .034"
4115 4034 3969 3916 3872 3877 3842 3811 3785 3761 3741
Concrete + Deck = 52.1 psf
Icr = 64.6 in4/ft
Mno/= 58.5 kip-in/ft
4
(Icr+Iu)/2 = 89.54 in /ft
Iu = 114.5 in4/ft
Mno= 89.5 kip-in/ft
4'-0"

4'-6"

10'-0" 10'-6" 11'-0"

B PANELS

All Gages

Single
7' - 9"
8' - 5"

5'-0"

Vertical Load Span (in)

16

Gage
18
16

2W PANELS

4'-0"

Vertical Load Span (in)

18

Triple
6' - 9"
8' - 0"

Vertical Load Span (in)

Vertical Load Span (in)

20

Maximum Unshored Span (in)

Double
6' - 3"
7' - 6"

3W PANELS

GA

Single
5' - 9"
6' - 10"

GENERAL INFORMATION

TABLE OF CONTENTS

4.4 BH-36 Composite Deck


6" Total Slab Depth
Normal Weight Concrete (145 pcf)
Concrete Volume 1.548yd3/100ft2
2 Hour Fire Rating
Gage
22
20

GA

22

Single
5' - 4"
6' - 4"

4'-0"

4'-6"

ASD, W/
LRFD, W
L/360

1972
2958
-

1581
2530
-

5262
4867
4837
4808
63.5
130.7

5164
4814
4786
4761
psf
in4/ft

4'-0"

4'-6"

Single
7' - 3"
7' - 10"

Double
8' - 7"
9' - 7"

Triple
8' - 11"
9' - 9"

5'-6"

6'-0"

6'-6"

7'-0"

7'-6"

8'-0"

8'-6"

9'-0"

9'-6"

1272
2035
-

1043
1669
-

869
1390
-

733
1173
-

626
1001
-

539
862
-

468
748
-

409
654
-

360
575
-

318
509
-

282
452
-

5086
4771
4746
4724

5022
4736
4713
4693
Icr =
Iu =

4969
4706
4686
4667
75.7
185.8

4941
4698
4679
4662
in4/ft
in4/ft

4901
4676
4658
4642

4867
4656
4640
4625

4836
4639
4624
4610
Mno/=
Mno=

4810 4786
4624 4611
4610 4597
4597 4585
51.7 kip-in/ft
79.2 kip-in/ft

4776
4610
4597
4586

5'-0" 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0"


ASD & LRFD - Superimposed Load, W (psf)
1972 1753 1506 1236 1031 872 745 643 559 490 432
ASD, W/
2958 2629 2366 1978 1650 1395 1192 1028 895 784 691
LRFD, W
L/360
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
5449 5330 5235 5157 5092 5061 5012 4970 4933 4900 4871
PAF Base Steel .25"
4968 4902 4850 4807 4771 4765 4737 4714 4693 4674 4658
PAF Base Steel 0.109"
4931 4870 4821 4781 4747 4743 4717 4694 4674 4657 4641
#12 Screw Base Steel .034"
4900 4842 4796 4758 4726 4724 4699 4678 4659 4642 4628
Concrete + Deck = 63.8 psf
Icr = 86.6 in4/ft
Mno/= 60.9 kip-in/ft
(Icr+Iu)/2 = 138.6 in4/ft
Iu = 190.6 in4/ft
Mno= 93.2 kip-in/ft

9'-6"

4757
4599
4587
4576
Vn/ =
Vn =

383
612
-

341
545
-

4862
4659
4644
4631

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"
Concrete + Deck =
(Icr+Iu)/2 =

ASD & LRFD - Superimposed Load, W (psf)

LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern

5'-0" 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6"


ASD & LRFD - Superimposed Load, W (psf)
1972 1753 1577 1434 1315 1129 967 836 729 640
ASD, W/
2958 2629 2366 2151 1972 1806 1547 1338 1166 1024
LRFD, W
L/360
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
5837 5673 5543 5436 5347 5314 5246 5187 5136 5091
PAF Base Steel .25"
5177 5087 5015 4956 4907 4908 4869 4836 4806 4781
PAF Base Steel 0.109"
5129 5044 4977 4921 4875 4878 4842 4810 4782 4758
#12 Screw Base Steel .034"
5096 5015 4950 4897 4853 4858 4823 4792 4766 4742
Concrete + Deck = 64.4 psf
Icr = 105.7 in4/ft
Mno/= 78.0
4
(Icr+Iu)/2 = 152.7 in /ft
Iu = 199.7 in4/ft
Mno= 119.4
Vertical Load Span (in)

4'-0"

4'-0"

4'-6"

4'-6"

5'-0" 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6"


ASD & LRFD - Superimposed Load, W (psf)
1972 1753 1577 1434 1315 1213 1127 1023 893 785
ASD, W/
2958 2629 2366 2151 1972 1820 1690 1577 1429 1257
LRFD, W
L/360
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
6250 6040 5871 5734 5619 5587 5499 5423 5356 5298
PAF Base Steel .25"
5401 5285 5192 5116 5053 5065 5014 4970 4932 4898
PAF Base Steel 0.109"
5309 5203 5118 5049 4991 5008 4962 4921 4886 4855
#12 Screw Base Steel .034"
5322 5216 5131 5061 5004 5021 4974 4933 4898 4867
Concrete + Deck = 65.1 psf
Icr = 122.9 in4/ft
Mno/= 94.5
(Icr+Iu)/2 = 165.6 in4/ft
Iu = 208.3 in4/ft
Mno= 144.7

10'-0" 10'-6" 11'-0"


252
403
-

225
360
-

4739 4723
4589 4580
4577 4568
4566 4558
3.94 kip/ft
5.92 kip/ft

10'-0" 10'-6" 11'-0"

9'-0"

9'-6"

4838
4645
4631
4618
Vn/ =
Vn =

566
905
-

503
805
-

449
719
-

5051
4758
4736
4721
kip-in/ft
kip-in/ft

5043
4766
4746
4732

9'-0"

9'-6"

5010
4746
4727
4713
Vn/ =
Vn =

695
1112
-

619
990
-

554
886
-

5245
4868
4827
4839
kip-in/ft
kip-in/ft

5244
4886
4847
4859

5199
4859
4823
4835
Vn/ =
Vn =

304
487
-

273
437
-

4816 4796
4633 4621
4619 4608
4607 4597
3.94 kip/ft
5.92 kip/ft

10'-0" 10'-6" 11'-0"


403
645
-

363
580
-

4979 4951
4728 4711
4710 4694
4697 4682
3.94 kip/ft
5.92 kip/ft

10'-0" 10'-6" 11'-0"


498
797
-

449
719
-

5159 5122
4835 4814
4800 4780
4812 4792
3.94 kip/ft
5.92 kip/ft

All Gages

16

Gage
18
16

5'-0"

Vertical Load Span (in)

18

Triple
6' - 4"
7' - 5"

Vertical Load Span (in)

Vertical Load Span (in)

20

Maximum Unshored Span (in)

Double
5' - 11"
7' - 1"

LRFD - Diaphragm Shear, Sn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4
6x6 W2.9xW2.9
6x6 W4.0xW4.0
4x4 W4xW4
4x4 W6xW6
3/4" Welded Shear Studs
As = 0.028 in2/ft
As = 0.058 in2/ft
As = 0.080 in2/ft
As = 0.120 in2/ft
As = 0.180 in2/ft
6 in o.c.
n/a
7010
8000
9800
12500
12 in o.c.
n/a
7010
8000
9800
12500
18 in o.c.
n/a
7010
8000
8790
8790

116

Composite and Non-Composite Deck Catalog May 2014

www.ascsd.com

TABLE OF CONTENTS

BH-36 Composite Deck 4.4


6 34" Total Slab Depth
Normal Weight Concrete (145 pcf)

Concrete Volume 1.780yd3/100ft2


3 Hour Fire Rating


Gage
22
20

22

4'-6"

ASD, W/
LRFD, W
L/360

2334
3501
-

1879
3007
-

5997
5603
5572
5544
72.7
184.9

5900
5549
5522
5497
psf
in4/ft

4'-0"

4'-6"

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"
Concrete + Deck =
(Icr+Iu)/2 =

Double
8' - 2"
9' - 1"

5'-0"

5'-6"

6'-0"

6'-6"

7'-0"

7'-6"

8'-0"

8'-6"

9'-0"

9'-6"

1512
2419
-

1240
1984
-

1033
1653
-

872
1396
-

745
1191
-

642
1027
-

557
892
-

487
780
-

429
686
-

379
607
-

337
539
-

5822
5506
5482
5459

5758
5471
5449
5428
Icr =
Iu =

5705
5442
5422
5403
102.5
267.4

5676
5434
5415
5397
in4/ft
in4/ft

5637
5411
5394
5378

5602
5392
5376
5361

5572
5375
5360
5345
Mno/=
Mno=

5512
5346
5333
5321

ASD & LRFD - Superimposed Load, W (psf)

LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern

4'-0"

5546 5522
5360 5347
5346 5333
5332 5320
61.4 kip-in/ft
94.0 kip-in/ft

4'-6"

269
431
-

9'-0"

9'-6"

5492
5335
5322
5311
Vn/ =
Vn =

5475 5459
5324 5315
5313 5304
5302 5294
4.67 kip/ft
7.00 kip/ft

515
825
-

457
731
-

407
651
-

5607
5393
5377
5363
kip-in/ft
kip-in/ft

5597
5395
5380
5367

9'-0"

9'-6"

5573
5381
5366
5354
Vn/ =
Vn =

677
1084
-

602
964
-

538
861
-

5786
5493
5472
5457
kip-in/ft
kip-in/ft

5779
5501
5481
5467

5715 5687
5464 5447
5445 5430
5433 5418
4.67 kip/ft
7.00 kip/ft

9'-0"

9'-6"

5745
5482
5462
5449
Vn/ =
Vn =

834
1335
-

743
1189
-

665
1064
-

598
957
-

5981
5603
5562
5575
kip-in/ft
kip-in/ft

5979
5622
5583
5595

5935
5595
5558
5570
Vn/ =
Vn =

10'-0" 10'-6" 11'-0"


364
583
-

327
523
-

5551 5532
5368 5357
5354 5343
5343 5332
4.67 kip/ft
7.00 kip/ft

10'-0" 10'-6" 11'-0"


483
773
-

435
696
-

10'-0" 10'-6" 11'-0"


540
864
-

5895 5858
5571 5549
5536 5516
5548 5528
4.67 kip/ft
7.00 kip/ft

www.ascsd.com

Composite and Non-Composite Deck Catalog May 2014

117

ACUSTADEK

LRFD - Diaphragm Shear, Sn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4
6x6 W2.9xW2.9
6x6 W4.0xW4.0
4x4 W4xW4
4x4 W6xW6
3/4" Welded Shear Studs
As = 0.028 in2/ft
As = 0.058 in2/ft
As = 0.080 in2/ft
As = 0.120 in2/ft
As = 0.180 in2/ft
6 in o.c.
n/a
7750
8740
10540
13240
12 in o.c.
n/a
7750
8740
10540
13180
18 in o.c.
n/a
7750
8740
8790
8790

D PANEL

5'-0" 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6"


ASD & LRFD - Superimposed Load, W (psf)
2334 2074 1867 1697 1556 1436 1334 1226 1070 942
ASD, W/
3501 3112 2801 2546 2334 2154 2000 1867 1713 1507
LRFD, W
L/360
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
6986 6775 6607 6469 6354 6323 6235 6159 6092 6033
PAF Base Steel .25"
6137 6021 5928 5852 5788 5801 5750 5706 5668 5634
PAF Base Steel 0.109"
6045 5939 5854 5785 5727 5744 5697 5657 5621 5590
#12 Screw Base Steel .034"
6057 5951 5866 5797 5739 5756 5710 5669 5634 5602
Concrete + Deck = 74.3 psf
Icr = 168.1 in4/ft
Mno/= 113.1
(Icr+Iu)/2 = 232.9 in4/ft
Iu = 297.7 in4/ft
Mno= 173.0

301
481
-

C PANELS

4'-6"

10'-0" 10'-6" 11'-0"

N PANELS

5'-0" 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6"


ASD & LRFD - Superimposed Load, W (psf)
2334 2074 1867 1697 1556 1349 1156 1000 872 766
ASD, W/
3501 3112 2801 2546 2334 2154 1849 1599 1395 1226
LRFD, W
L/360
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
6572 6409 6278 6171 6082 6049 5982 5923 5872 5826
PAF Base Steel .25"
5913 5823 5751 5692 5643 5643 5605 5571 5542 5516
PAF Base Steel 0.109"
5865 5780 5712 5657 5611 5614 5577 5546 5518 5494
#12 Screw Base Steel .034"
5831 5750 5686 5633 5589 5593 5558 5528 5501 5478
Concrete + Deck = 73.7 psf
Icr = 144.0 in4/ft
Mno/= 93.1
4
(Icr+Iu)/2 = 215.1 in /ft
Iu = 286.1 in4/ft
Mno= 142.4
4'-0"

Triple
8' - 6"
9' - 4"

B PANELS

All Gages

Single
7' - 0"
7' - 6"

5'-0" 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6"


ASD & LRFD - Superimposed Load, W (psf)
2334 2074 1793 1472 1228 1038 888 766 667 584
ASD, W/
3501 3112 2801 2355 1965 1661 1420 1226 1067 935
LRFD, W
L/360
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
6184 6065 5970 5893 5828 5797 5748 5706 5669 5636
PAF Base Steel .25"
5703 5638 5586 5543 5507 5501 5473 5449 5428 5410
PAF Base Steel 0.109"
5667 5606 5556 5516 5483 5478 5452 5430 5410 5393
#12 Screw Base Steel .034"
5636 5578 5532 5494 5462 5459 5435 5413 5395 5378
Concrete + Deck = 73.1 psf
Icr = 117.5 in4/ft
Mno/= 72.4
(Icr+Iu)/2 = 195.7 in4/ft
Iu = 273.9 in4/ft
Mno= 110.8

Vertical Load Span (in)

16

Gage
18
16

2W PANELS

4'-0"

Vertical Load Span (in)

18

Triple
6' - 0"
7' - 1"

Vertical Load Span (in)

Vertical Load Span (in)

20

Maximum Unshored Span (in)

Double
5' - 8"
6' - 9"

3W PANELS

GA

Single
5' - 1"
6' - 0"

GENERAL INFORMATION

TABLE OF CONTENTS

4.4 BH-36 Composite Deck

3 12" Total Slab Depth


Light Weight Concrete (110 pcf)
Concrete Volume 0.776yd3/100ft2

Gage
22
20

GA

22

Single
7' - 1"
8' - 6"

4'-0"

4'-6"

ASD, W/
LRFD, W
L/360

787
1260
-

618
989
-

2154
1759
1729
1701
25.2
30.97

2056
1706
1679
1654
psf
in4/ft

4'-0"

4'-6"

Single
9' - 9"
10' - 6"

Double
11' - 4"
12' - 10"

Triple
12' - 0"
12' - 6"

5'-6"

6'-0"

6'-6"

7'-0"

7'-6"

8'-0"

8'-6"

9'-0"

9'-6"

497
795
-

408
652
-

339
543
-

286
458
-

244
391
-

210
337
-

183
292
-

156
255
156

131
225
131

112
198
112

96
176
96

1978
1663
1638
1616

1915
1628
1606
1585
Icr =
Iu =

1862 1833
1599 1590
1578 1571
1559 1554
23.1 in4/ft
38.8 in4/ft

1793
1568
1550
1534

1759
1549
1532
1517

1729
1532
1516
1502
Mno/=
Mno=

1702 1679
1517 1503
1502 1490
1489 1477
20.2 kip-in/ft
31.0 kip-in/ft

1669
1503
1490
1478

5'-0" 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0"


ASD & LRFD - Superimposed Load, W (psf)
919
722 581 477 398 336 287 243 200 167 141
ASD, W/
1426 1155 930 763 636 538 459 396 344 302 266
LRFD, W
L/360
243 200 167 141
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
2343 2224 2129 2051 1986 1955 1906 1864 1827 1795 1766
PAF Base Steel .25"
1862 1797 1744 1701 1666 1659 1632 1608 1587 1568 1552
PAF Base Steel 0.109"
1826 1764 1715 1675 1641 1637 1611 1588 1569 1551 1536
#12 Screw Base Steel .034"
1795 1737 1690 1652 1621 1618 1593 1572 1553 1537 1522
Concrete + Deck = 25.5 psf
Icr = 26.0 in4/ft
Mno/= 23.5 kip-in/ft
(Icr+Iu)/2 = 33.23 in4/ft
Iu = 40.5 in4/ft
Mno= 36.0 kip-in/ft

9'-6"

1649
1491
1479
1468
Vn/ =
Vn =

120
235
120

103
209
103

1756
1554
1538
1525

9'-6"

1732
1540
1525
1513
Vn/ =
Vn =

133
300
133

114
267
114

1942
1664
1644
1630

9'-6"

1908
1644
1625
1612
Vn/ =
Vn =

145
361
145

125
323
125

2146
1788
1749
1758

2101
1762
1725
1733
Vn/ =
Vn =

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"
Concrete + Deck =
(Icr+Iu)/2 =

ASD & LRFD - Superimposed Load, W (psf)

LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern

5'-0" 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0"


ASD & LRFD - Superimposed Load, W (psf)
951
845 727 598 499 416 333 271 223 186 157
ASD, W/
1426 1267 1141 956 799 676 578 500 435 382 337
LRFD, W
L/360
416 333 271 223 186 157
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
2735 2572 2441 2334 2245 2212 2144 2086 2034 1989 1949
PAF Base Steel .25"
2075 1985 1913 1854 1805 1806 1767 1734 1705 1679 1656
PAF Base Steel 0.109"
2027 1943 1875 1819 1773 1776 1740 1708 1681 1656 1634
#12 Screw Base Steel .034"
1994 1913 1848 1795 1751 1756 1721 1690 1664 1640 1620
Concrete + Deck = 26.2 psf
Icr = 30.6 in4/ft
Mno/= 29.3 kip-in/ft
Iu = 43.3 in4/ft
(Icr+Iu)/2 = 36.95 in4/ft
Mno= 44.8 kip-in/ft
Vertical Load Span (in)

4'-0"

4'-0"

4'-6"

4'-6"

5'-0" 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0"


ASD & LRFD - Superimposed Load, W (psf)
951 845 760 691 577 454 363 295 243 203 171
ASD, W/
1426 1267 1141 1037 951 808 692 599 522 459 406
LRFD, W
L/360
577 454 363 295 243 203 171
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
3153 2942 2774 2636 2521 2490 2402 2325 2259 2200 2147
PAF Base Steel .25"
2303 2187 2094 2018 1955 1967 1916 1873 1834 1800 1770
PAF Base Steel 0.109"
2211 2105 2020 1951 1893 1910 1864 1823 1788 1757 1729
#12 Screw Base Steel .034"
2220 2114 2029 1960 1902 1919 1872 1832 1796 1765 1737
Concrete + Deck = 26.8 psf
Icr = 34.6 in4/ft
Mno/= 34.8 kip-in/ft
(Icr+Iu)/2 = 40.33 in4/ft
Iu = 46.0 in4/ft
Mno= 53.2 kip-in/ft

10'-0" 10'-6" 11'-0"


83
157
83

72
140
72

1631 1615
1481 1472
1469 1461
1459 1450
1.90 kip/ft
2.85 kip/ft

10'-0" 10'-6" 11'-0"


89
187
89

77
168
77

1710 1690
1527 1515
1513 1502
1501 1491
1.90 kip/ft
2.85 kip/ft

10'-0" 10'-6" 11'-0"


99
240
99

86
216
86

1877 1849
1626 1610
1608 1592
1595 1580
1.90 kip/ft
2.85 kip/ft

10'-0" 10'-6" 11'-0"


108
290
108

94
261
94

2061 2025
1738 1716
1703 1682
1711 1690
1.90 kip/ft
2.85 kip/ft

All Gages

16

Gage
18
16

5'-0"

Vertical Load Span (in)

18

Triple
8' - 5"
10' - 2"

Vertical Load Span (in)

Vertical Load Span (in)

20

Maximum Unshored Span (in)

Double
7' - 2"
9' - 0"

LRFD - Diaphragm Shear, Sn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4
6x6 W2.9xW2.9
6x6 W4.0xW4.0
4x4 W4xW4
4x4 W6xW6
3/4" Welded Shear Studs
As = 0.028 in2/ft
As = 0.058 in2/ft
As = 0.080 in2/ft
As = 0.120 in2/ft
As = 0.180 in2/ft
6 in o.c.
3200
4550
5540
7340
10040
12 in o.c.
3200
4550
5540
7340
10040
18 in o.c.
3200
4550
5540
7340
8790

118

Composite and Non-Composite Deck Catalog May 2014

www.ascsd.com

TABLE OF CONTENTS

BH-36 Composite Deck 4.4


4" Total Slab Depth
Light Weight Concrete (110 pcf)

Concrete Volume 0.931yd3/100ft2


1 Hour Fire Rating


Gage
22
20

22

4'-6"

ASD, W/
LRFD, W
L/360

1001
1601
-

786
1258
-

2478
2083
2053
2025
29.9
45.86

2380
2030
2003
1978
psf
in4/ft

4'-0"

4'-6"

Double
10' - 11"
12' - 3"

Triple
11' - 6"
12' - 1"

5'-6"

6'-0"

6'-6"

7'-0"

7'-6"

8'-0"

8'-6"

9'-0"

9'-6"

632
1012
-

519
830
-

432
692
-

365
584
-

312
499
-

269
430
-

233
373
-

204
327
-

180
288
-

159
254
-

141
226
-

2303
1987
1962
1940

2239
1952
1930
1909
Icr =
Iu =

2186 2157
1923 1914
1902 1896
1883 1878
33.8 in4/ft
57.9 in4/ft

2117
1892
1874
1858

2083
1873
1856
1841

2053
1856
1840
1826
Mno/=
Mno=

2026 2003
1841 1827
1826 1814
1813 1801
25.7 kip-in/ft
39.3 kip-in/ft

1993
1827
1814
1802

5'-0" 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0"


ASD & LRFD - Superimposed Load, W (psf)
1132 920 741 608 507 429 367 317 276 241 208
ASD, W/
1698 1471 1185 973 812 686 587 507 441 386 341
LRFD, W
L/360
208
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
2667 2548 2453 2375 2310 2279 2231 2188 2151 2119 2090
PAF Base Steel .25"
2186 2121 2068 2025 1990 1983 1956 1932 1911 1892 1876
PAF Base Steel 0.109"
2150 2088 2039 1999 1965 1961 1935 1912 1893 1875 1860
#12 Screw Base Steel .034"
2119 2061 2014 1976 1945 1942 1917 1896 1877 1861 1846
Concrete + Deck = 30.2 psf
Icr = 38.1 in4/ft
Mno/= 29.9 kip-in/ft
(Icr+Iu)/2 = 49.16 in4/ft
Iu = 60.3 in4/ft
Mno= 45.8 kip-in/ft

9'-6"

1973
1815
1803
1792
Vn/ =
Vn =

177
302
177

152
269
152

2080
1878
1862
1849

9'-6"

2056
1864
1849
1837
Vn/ =
Vn =

197
386
197

169
345
169

2266
1988
1968
1954

9'-6"

2232
1968
1949
1936
Vn/ =
Vn =

215
467
215

184
418
184

2470
2112
2073
2082

2425
2086
2049
2057
Vn/ =
Vn =

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"
Concrete + Deck =
(Icr+Iu)/2 =

ASD & LRFD - Superimposed Load, W (psf)

LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern

4'-0"

1955 1939
1805 1796
1793 1785
1783 1774
2.26 kip/ft
3.40 kip/ft

10'-0" 10'-6" 11'-0"


131
241
131

114
216
114

2034 2014
1851 1839
1837 1826
1825 1815
2.26 kip/ft
3.40 kip/ft

10'-0" 10'-6" 11'-0"


146
310
146

127
279
127

2201 2174
1950 1934
1932 1916
1919 1904
2.26 kip/ft
3.40 kip/ft

10'-0" 10'-6" 11'-0"


159
375
159

138
339
138

2385 2349
2062 2040
2027 2006
2035 2015
2.26 kip/ft
3.40 kip/ft

www.ascsd.com

Composite and Non-Composite Deck Catalog May 2014

119

ACUSTADEK

LRFD - Diaphragm Shear, Sn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4
6x6 W2.9xW2.9
6x6 W4.0xW4.0
4x4 W4xW4
4x4 W6xW6
3/4" Welded Shear Studs
As = 0.028 in2/ft
As = 0.058 in2/ft
As = 0.080 in2/ft
As = 0.120 in2/ft
As = 0.180 in2/ft
6 in o.c.
3690
5040
6030
7830
10530
12 in o.c.
3690
5040
6030
7830
10530
18 in o.c.
3690
5040
6030
7830
8790

D PANEL

5'-0" 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0"


ASD & LRFD - Superimposed Load, W (psf)
1132 1006 906 823 755 650 537 437 360 300 253
ASD, W/
1698 1509 1358 1235 1132 1040 891 772 674 592 524
LRFD, W
L/360
537 437 360 300 253
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
3477 3266 3098 2960 2845 2814 2726 2649 2583 2524 2471
PAF Base Steel .25"
2628 2511 2418 2342 2279 2291 2241 2197 2158 2124 2094
PAF Base Steel 0.109"
2535 2429 2345 2275 2217 2234 2188 2147 2112 2081 2053
#12 Screw Base Steel .034"
2544 2438 2353 2284 2226 2243 2196 2156 2120 2089 2061
Concrete + Deck = 31.5 psf
Icr = 51.0 in4/ft
Mno/= 44.6 kip-in/ft
(Icr+Iu)/2 = 59.64 in4/ft
Iu = 68.2 in4/ft
Mno= 68.3 kip-in/ft

106
181
106

C PANELS

4'-6"

122
202
122

N PANELS

5'-0" 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0"


ASD & LRFD - Superimposed Load, W (psf)
1132 1006 906 766 640 542 464 400 330 275 232
ASD, W/
1698 1509 1358 1226 1024 867 743 642 560 492 435
LRFD, W
L/360
400 330 275 232
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
3059 2896 2765 2658 2569 2536 2468 2410 2358 2313 2273
PAF Base Steel .25"
2399 2309 2237 2179 2129 2130 2091 2058 2029 2003 1980
PAF Base Steel 0.109"
2351 2267 2199 2144 2097 2100 2064 2032 2005 1980 1958
#12 Screw Base Steel .034"
2318 2237 2172 2119 2075 2080 2045 2015 1988 1965 1944
Concrete + Deck = 30.8 psf
Icr = 45.0 in4/ft
Mno/= 37.5 kip-in/ft
4
(Icr+Iu)/2 = 54.67 in /ft
Iu = 64.4 in4/ft
Mno= 57.3 kip-in/ft
4'-0"

4'-6"

10'-0" 10'-6" 11'-0"

B PANELS

All Gages

Single
9' - 3"
10' - 0"

5'-0"

Vertical Load Span (in)

16

Gage
18
16

2W PANELS

4'-0"

Vertical Load Span (in)

18

Triple
8' - 1"
9' - 8"

Vertical Load Span (in)

Vertical Load Span (in)

20

Maximum Unshored Span (in)

Double
7' - 0"
8' - 8"

3W PANELS

GA

Single
6' - 9"
8' - 1"

GENERAL INFORMATION

TABLE OF CONTENTS

4.4 BH-36 Composite Deck

4 12" Total Slab Depth


Light Weight Concrete (110 pcf)
Concrete Volume 1.085yd3/100ft2

Gage
22
20

GA

22

Single
6' - 6"
7' - 9"

4'-0"

4'-6"

ASD, W/
LRFD, W
L/360

1227
1962
-

964
1542
-

2802
2408
2377
2349
34.5
64.87

2705
2354
2327
2302
psf
in4/ft

4'-0"

4'-6"

Single
8' - 10"
9' - 7"

Double
10' - 6"
11' - 9"

Triple
11' - 1"
11' - 8"

5'-6"

6'-0"

6'-6"

7'-0"

7'-6"

8'-0"

8'-6"

9'-0"

9'-6"

776
1241
-

637
1018
-

531
849
-

448
717
-

383
613
-

330
529
-

287
460
-

251
402
-

221
354
-

196
314
-

174
279
-

2627
2311
2287
2264

2563
2276
2254
2233
Icr =
Iu =

2510 2481
2247 2238
2226 2220
2207 2202
47.1 in4/ft
82.6 in4/ft

2441
2216
2199
2182

2407
2197
2180
2165

2377
2180
2164
2150
Mno/=
Mno=

2350 2327
2165 2151
2150 2138
2137 2125
31.4 kip-in/ft
48.1 kip-in/ft

2317
2151
2138
2126

5'-0" 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0"


ASD & LRFD - Superimposed Load, W (psf)
1325 1130 910 748 624 528 451 390 340 298 263
ASD, W/
1987 1766 1456 1196 998 844 722 624 543 476 420
LRFD, W
L/360
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
2991 2872 2777 2699 2634 2603 2555 2512 2475 2443 2414
PAF Base Steel .25"
2510 2445 2392 2350 2314 2307 2280 2256 2235 2217 2200
PAF Base Steel 0.109"
2474 2412 2363 2323 2289 2285 2259 2236 2217 2199 2184
#12 Screw Base Steel .034"
2443 2385 2338 2300 2269 2266 2241 2220 2201 2185 2170
Concrete + Deck = 34.9 psf
Icr = 53.1 in4/ft
Mno/= 36.7 kip-in/ft
(Icr+Iu)/2 = 69.5 in4/ft
Iu = 85.9 in4/ft
Mno= 56.2 kip-in/ft

9'-6"

2297
2139
2127
2116
Vn/ =
Vn =

233
373
-

208
333
-

2404
2202
2186
2173

9'-6"

2380
2188
2173
2161
Vn/ =
Vn =

279
479
279

239
429
239

2590
2312
2292
2278

9'-6"

2556
2292
2273
2260
Vn/ =
Vn =

304
581
304

261
520
261

2794
2436
2397
2406

2749
2410
2373
2381
Vn/ =
Vn =

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"
Concrete + Deck =
(Icr+Iu)/2 =

ASD & LRFD - Superimposed Load, W (psf)

LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern

5'-0" 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0"


ASD & LRFD - Superimposed Load, W (psf)
1325 1178 1060 947 791 670 574 497 433 381 328
ASD, W/
1987 1766 1590 1445 1266 1072 919 795 694 609 539
LRFD, W
L/360
328
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
3383 3220 3089 2982 2893 2860 2792 2734 2682 2637 2597
PAF Base Steel .25"
2724 2634 2561 2503 2453 2454 2415 2382 2353 2327 2304
PAF Base Steel 0.109"
2675 2591 2523 2468 2421 2425 2388 2356 2329 2304 2283
#12 Screw Base Steel .034"
2642 2561 2496 2443 2399 2404 2369 2339 2312 2289 2268
Concrete + Deck = 35.5 psf
Icr = 63.0 in4/ft
Mno/= 46.2 kip-in/ft
4
(Icr+Iu)/2 = 77.32 in /ft
Iu = 91.6 in4/ft
Mno= 70.7 kip-in/ft
Vertical Load Span (in)

4'-0"

4'-0"

4'-6"

4'-6"

5'-0" 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0"


ASD & LRFD - Superimposed Load, W (psf)
1325 1178 1060 963 883 806 691 599 509 424 357
ASD, W/
1987 1766 1590 1445 1325 1223 1106 958 837 736 652
LRFD, W
L/360
509 424 357
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
3801 3590 3422 3284 3169 3138 3050 2974 2907 2848 2796
PAF Base Steel .25"
2952 2835 2742 2666 2603 2615 2565 2521 2482 2448 2418
PAF Base Steel 0.109"
2859 2753 2669 2599 2541 2559 2512 2471 2436 2405 2377
#12 Screw Base Steel .034"
2868 2762 2677 2608 2550 2567 2520 2480 2444 2413 2385
Concrete + Deck = 36.1 psf
Icr = 71.7 in4/ft
Mno/= 55.2 kip-in/ft
(Icr+Iu)/2 = 84.35 in4/ft
Iu = 97.0 in4/ft
Mno= 84.5 kip-in/ft

10'-0" 10'-6" 11'-0"


156
249
-

140
224
-

2279 2263
2129 2120
2118 2109
2107 2099
2.65 kip/ft
3.97 kip/ft

10'-0" 10'-6" 11'-0"


185
298
185

161
268
161

2358 2338
2175 2163
2161 2150
2149 2139
2.65 kip/ft
3.97 kip/ft

10'-0" 10'-6" 11'-0"


206
385
206

179
347
179

2525 2498
2274 2258
2256 2240
2243 2228
2.65 kip/ft
3.97 kip/ft

10'-0" 10'-6" 11'-0"


225
468
225

196
422
196

2709 2673
2386 2364
2351 2330
2359 2339
2.65 kip/ft
3.97 kip/ft

All Gages

16

Gage
18
16

5'-0"

Vertical Load Span (in)

18

Triple
7' - 9"
9' - 2"

Vertical Load Span (in)

Vertical Load Span (in)

20

Maximum Unshored Span (in)

Double
6' - 10"
8' - 5"

LRFD - Diaphragm Shear, Sn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4
6x6 W2.9xW2.9
6x6 W4.0xW4.0
4x4 W4xW4
4x4 W6xW6
3/4" Welded Shear Studs
As = 0.028 in2/ft
As = 0.058 in2/ft
As = 0.080 in2/ft
As = 0.120 in2/ft
As = 0.180 in2/ft
6 in o.c.
4180
5530
6520
8320
11020
12 in o.c.
4180
5530
6520
8320
11020
18 in o.c.
4180
5530
6520
8320
8790

120

Composite and Non-Composite Deck Catalog May 2014

www.ascsd.com

TABLE OF CONTENTS

BH-36 Composite Deck 4.4


4" Total Slab Depth
Light Weight Concrete (110 pcf)

Concrete Volume 1.162yd3/100ft2


2 Hour Fire Rating


Gage
22
20

22

4'-6"

ASD, W/
LRFD, W
L/360

1343
2138
-

1055
1688
-

2964
2570
2539
2511
36.9
76.06

2867
2516
2489
2464
psf
in4/ft

4'-0"

4'-6"

Double
10' - 3"
11' - 7"

Triple
10' - 10"
11' - 6"

5'-6"

6'-0"

6'-6"

7'-0"

7'-6"

8'-0"

8'-6"

9'-0"

9'-6"

849
1359
-

697
1115
-

581
930
-

491
786
-

420
672
-

362
579
-

315
504
-

276
441
-

243
389
-

215
344
-

192
307
-

2789
2473
2449
2426

2725
2438
2416
2395
Icr =
Iu =

2672 2643
2409 2400
2388 2382
2369 2364
54.7 in4/ft
97.4 in4/ft

2603
2378
2361
2344

2569
2359
2342
2327

2539
2342
2326
2312
Mno/=
Mno=

2512 2489
2327 2313
2312 2300
2299 2287
34.4 kip-in/ft
52.6 kip-in/ft

2479
2313
2300
2288

5'-0" 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0"


ASD & LRFD - Superimposed Load, W (psf)
1426 1238 997 819 684 579 495 428 373 327 289
ASD, W/
2138 1901 1596 1311 1095 926 792 684 596 523 462
LRFD, W
L/360
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
3153 3034 2939 2861 2796 2765 2717 2674 2637 2605 2576
PAF Base Steel .25"
2672 2607 2554 2512 2476 2469 2442 2418 2397 2379 2362
PAF Base Steel 0.109"
2636 2574 2525 2485 2451 2447 2421 2398 2379 2361 2346
#12 Screw Base Steel .034"
2605 2547 2500 2463 2431 2428 2403 2382 2363 2347 2332
Concrete + Deck = 37.2 psf
Icr = 61.7 in4/ft
Mno/= 40.2 kip-in/ft
(Icr+Iu)/2 = 81.45 in4/ft
Iu = 101.2 in4/ft
Mno= 61.5 kip-in/ft

9'-6"

2459
2301
2289
2278
Vn/ =
Vn =

256
410
-

228
365
-

2566
2364
2348
2335

9'-6"

2542
2350
2335
2323
Vn/ =
Vn =

327
528
327

280
472
280

2752
2474
2454
2440

9'-6"

2718
2454
2435
2422
Vn/ =
Vn =

356
640
356

305
573
305

2956
2598
2560
2568

2911
2572
2535
2543
Vn/ =
Vn =

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"
Concrete + Deck =
(Icr+Iu)/2 =

ASD & LRFD - Superimposed Load, W (psf)

LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern

4'-0"

2442 2425
2291 2282
2280 2271
2269 2261
2.85 kip/ft
4.28 kip/ft

10'-0" 10'-6" 11'-0"


205
327
-

184
294
-

2520 2500
2337 2325
2323 2312
2311 2301
2.85 kip/ft
4.28 kip/ft

10'-0" 10'-6" 11'-0"


242
424
242

210
382
210

2687 2660
2436 2420
2418 2402
2405 2390
2.85 kip/ft
4.28 kip/ft

10'-0" 10'-6" 11'-0"


264
516
264

230
466
230

2871 2835
2548 2526
2513 2492
2521 2501
2.85 kip/ft
4.28 kip/ft

www.ascsd.com

Composite and Non-Composite Deck Catalog May 2014

121

ACUSTADEK

LRFD - Diaphragm Shear, Sn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4
6x6 W2.9xW2.9
6x6 W4.0xW4.0
4x4 W4xW4
4x4 W6xW6
3/4" Welded Shear Studs
As = 0.028 in2/ft
As = 0.058 in2/ft
As = 0.080 in2/ft
As = 0.120 in2/ft
As = 0.180 in2/ft
6 in o.c.
n/a
5780
6770
8570
11270
12 in o.c.
n/a
5780
6770
8570
11270
18 in o.c.
n/a
5780
6770
8570
8790

D PANEL

5'-0" 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0"


ASD & LRFD - Superimposed Load, W (psf)
1426 1267 1140 1037 950 877 761 659 576 497 419
ASD, W/
2138 1901 1711 1555 1426 1316 1218 1055 922
811
719
LRFD, W
L/360
497 419
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
3963 3752 3584 3446 3331 3300 3212 3136 3069 3010 2958
PAF Base Steel .25"
3114 2997 2904 2828 2765 2777 2727 2683 2644 2610 2580
PAF Base Steel 0.109"
3021 2915 2831 2761 2703 2721 2674 2633 2598 2567 2539
#12 Screw Base Steel .034"
3030 2924 2839 2770 2712 2729 2682 2642 2606 2575 2547
Concrete + Deck = 38.5 psf
Icr = 83.7 in4/ft
Mno/= 60.7 kip-in/ft
(Icr+Iu)/2 = 98.88 in4/ft
Iu = 114.0 in4/ft
Mno= 92.9 kip-in/ft

154
246
-

C PANELS

4'-6"

171
274
-

N PANELS

5'-0" 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0"


ASD & LRFD - Superimposed Load, W (psf)
1426 1267 1140 1037 870 737 631 546 477 419 371
ASD, W/
2138 1901 1711 1555 1391 1179 1010 874 763 670 593
LRFD, W
L/360
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
3545 3382 3251 3144 3055 3022 2954 2896 2844 2799 2759
PAF Base Steel .25"
2886 2796 2724 2665 2615 2616 2577 2544 2515 2489 2466
PAF Base Steel 0.109"
2837 2753 2685 2630 2583 2587 2550 2518 2491 2466 2445
#12 Screw Base Steel .034"
2804 2723 2658 2605 2561 2566 2531 2501 2474 2451 2430
Concrete + Deck = 37.8 psf
Icr = 73.4 in4/ft
Mno/= 50.7 kip-in/ft
4
(Icr+Iu)/2 = 90.62 in /ft
Iu = 107.8 in4/ft
Mno= 77.6 kip-in/ft
4'-0"

4'-6"

10'-0" 10'-6" 11'-0"

B PANELS

All Gages

Single
8' - 8"
9' - 4"

5'-0"

Vertical Load Span (in)

16

Gage
18
16

2W PANELS

4'-0"

Vertical Load Span (in)

18

Triple
7' - 7"
9' - 0"

Vertical Load Span (in)

Vertical Load Span (in)

20

Maximum Unshored Span (in)

Double
6' - 9"
8' - 3"

3W PANELS

GA

Single
6' - 4"
7' - 7"

GENERAL INFORMATION

TABLE OF CONTENTS

4.4 BH-36 Composite Deck


5 1116" Total Slab Depth
Light Weight Concrete (110 pcf)
Concrete Volume 1.452yd3/100ft2
3 Hour Fire Rating
Gage
22
20

GA

22

Single
6' - 0"
7' - 1"

4'-0"

4'-6"

ASD, W/
LRFD, W
L/360

1793
2743
-

1409
2255
-

3572
3177
3147
3118
45.6
128.9

3474
3124
3096
3071
psf
in4/ft

4'-0"

4'-6"

Single
8' - 1"
8' - 9"

Double
9' - 8"
10' - 10"

Triple
10' - 1"
10' - 10"

5'-6"

6'-0"

6'-6"

7'-0"

7'-6"

8'-0"

8'-6"

9'-0"

9'-6"

1135
1816
-

932
1491
-

778
1244
-

658
1052
-

562
900
-

485
777
-

423
676
-

370
593
-

327
523
-

290
463
-

258
413
-

3396
3081
3056
3034

3332
3046
3023
3003
Icr =
Iu =

3279
3016
2996
2977
89.2
168.7

3251
3008
2989
2972
in4/ft
in4/ft

3211
2986
2968
2952

3177
2966
2950
2935

3146
2949
2934
2920
Mno/=
Mno=

3120 3096
2934 2921
2920 2907
2907 2895
45.9 kip-in/ft
70.2 kip-in/ft

3086
2920
2907
2896

5'-0" 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0"


ASD & LRFD - Superimposed Load, W (psf)
1829 1625 1337 1099 918 777 665 575 501 440 389
ASD, W/
2743 2438 2139 1758 1468 1243 1064 920 802 704 622
LRFD, W
L/360
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
3761 3642 3547 3469 3404 3373 3324 3282 3245 3212 3183
PAF Base Steel .25"
3280 3214 3162 3119 3083 3077 3049 3026 3005 2986 2970
PAF Base Steel 0.109"
3243 3182 3133 3093 3059 3055 3029 3006 2986 2969 2953
#12 Screw Base Steel .034"
3212 3154 3108 3070 3038 3036 3011 2990 2971 2954 2940
Concrete + Deck = 46.0 psf
Icr = 101.1 in4/ft
Mno/= 53.8 kip-in/ft
(Icr+Iu)/2 = 137.9 in4/ft
Iu = 174.7 in4/ft
Mno= 82.3 kip-in/ft

9'-6"

3067
2909
2897
2886
Vn/ =
Vn =

345
553
-

308
493
-

3174
2971
2956
2943

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"
Concrete + Deck =
(Icr+Iu)/2 =

ASD & LRFD - Superimposed Load, W (psf)

LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern

5'-0" 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6"


ASD & LRFD - Superimposed Load, W (psf)
1829 1625 1463 1330 1175 996 854 739 646 568
ASD, W/
2743 2438 2194 1995 1829 1593 1366 1183 1033 908
LRFD, W
L/360
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
4153 3989 3859 3752 3663 3630 3562 3503 3452 3407
PAF Base Steel .25"
3493 3403 3331 3272 3223 3224 3185 3152 3122 3096
PAF Base Steel 0.109"
3445 3360 3293 3237 3191 3194 3158 3126 3098 3074
#12 Screw Base Steel .034"
3412 3331 3266 3213 3169 3174 3139 3108 3082 3058
Concrete + Deck = 46.6 psf
Icr = 121.2 in4/ft
Mno/= 68.3
4
(Icr+Iu)/2 = 153.4 in /ft
Iu = 185.6 in4/ft
Mno= 104.5
Vertical Load Span (in)

4'-0"

4'-0"

4'-6"

4'-6"

5'-0" 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6"


ASD & LRFD - Superimposed Load, W (psf)
1829 1625 1463 1330 1219 1125 1035 897 784 690
ASD, W/
2743 2438 2194 1995 1829 1688 1567 1435 1254 1104
LRFD, W
L/360
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
4570 4360 4191 4053 3939 3907 3819 3743 3676 3617
PAF Base Steel .25"
3721 3605 3512 3436 3373 3385 3334 3290 3252 3218
PAF Base Steel 0.109"
3629 3523 3438 3369 3311 3328 3281 3241 3206 3174
#12 Screw Base Steel .034"
3638 3532 3447 3377 3320 3337 3290 3249 3214 3183
Concrete + Deck = 47.2 psf
Icr = 138.9 in4/ft
Mno/= 82.2
(Icr+Iu)/2 = 167.4 in4/ft
Iu = 195.8 in4/ft
Mno= 125.8

10'-0" 10'-6" 11'-0"


231
369
-

207
332
-

3049 3033
2899 2890
2887 2878
2876 2868
3.66 kip/ft
5.49 kip/ft

10'-0" 10'-6" 11'-0"

9'-0"

9'-6"

3150
2957
2943
2930
Vn/ =
Vn =

503
804
-

448
716
-

401
641
-

3367
3074
3052
3037
kip-in/ft
kip-in/ft

3359
3082
3062
3048

9'-0"

9'-6"

3326
3062
3043
3029
Vn/ =
Vn =

612
979
-

546
873
-

489
782
-

3565
3188
3147
3155
kip-in/ft
kip-in/ft

3563
3206
3167
3175

3519
3179
3143
3151
Vn/ =
Vn =

276
442
-

249
398
-

3128 3108
2945 2933
2931 2920
2919 2909
3.66 kip/ft
5.49 kip/ft

10'-0" 10'-6" 11'-0"


360
576
-

325
520
-

3295 3267
3044 3027
3026 3010
3013 2998
3.66 kip/ft
5.49 kip/ft

10'-0" 10'-6" 11'-0"


440
704
-

388
637
388

3479 3442
3155 3134
3120 3100
3128 3108
3.66 kip/ft
5.49 kip/ft

All Gages

16

Gage
18
16

5'-0"

Vertical Load Span (in)

18

Triple
7' - 1"
8' - 5"

Vertical Load Span (in)

Vertical Load Span (in)

20

Maximum Unshored Span (in)

Double
6' - 6"
7' - 10"

LRFD - Diaphragm Shear, Sn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4
6x6 W2.9xW2.9
6x6 W4.0xW4.0
4x4 W4xW4
4x4 W6xW6
3/4" Welded Shear Studs
As = 0.028 in2/ft
As = 0.058 in2/ft
As = 0.080 in2/ft
As = 0.120 in2/ft
As = 0.180 in2/ft
6 in o.c.
n/a
6700
7690
9490
12190
12 in o.c.
n/a
6700
7690
9490
12190
18 in o.c.
n/a
6700
7690
8790
8790

122

Composite and Non-Composite Deck Catalog May 2014

www.ascsd.com

TABLE OF CONTENTS
GENERAL INFORMATION
3W PANELS
2W PANELS
B PANELS
N PANELS
C PANELS
D PANEL
ACUSTADEK

www.ascsd.com

Composite and Non-Composite Deck Catalog May 2014

123

TABLE OF CONTENTS

5.1 NH-32
3-7/8

4-1/8

3-7/8

4-1/8

2-1/8

2-1/8

32

32
NHN-32 Profile

NH-32 Profile

36/5

32/5 Attachment Patterns

N Series Embossment
Panel Properties

Gage

Weight

22
20
18
16

w
psf
1.70
2.03
2.68
3.35
Compression

Gage

Area

22
20
18
16

Ae
in2/ft
0.272
0.372
0.604
0.871

Base Metal
Thickness Yield Strength
t
in
0.029
0.035
0.047
0.059

Fy
ksi
50
50
50
50

Tensile
Strength

Area

Fu
ksi
65
65
65
65

Ag
in2/ft
0.569
0.681
0.902
1.123

Effective Section Modulus at Fy


Bending
Distance to
Section
N.A. from
Section
Modulus
Bottom
Modulus
Se+
yb
Sein3/ft
in
in3/ft
0.346
1.37
0.402
0.446
1.41
0.505
0.661
1.48
0.715
0.879
1.54
0.927

Gage
22
20
18
16

124

Condition

1"
End
500
Interior
876
End
709
Interior
1240
End
1221
Interior
2133
End
1864
Interior
3260
Web Crippling Constraints

Ig
in4/ft
0.814
0.968
1.275
1.575

yb
in
1.68
1.68
1.69
1.69

Sg
in3/ft
0.483
0.576
0.755
0.931

Radius of
Gyration
r
in
1.195
1.193
1.189
1.185

Effective Moment of Inertia for Deflection


Distance to
N.A. from
Bottom
yb
in
1.78
1.76
1.72
1.70

Reactions at Supports (plf) Based on Web Crippling


Allowable (Rn/)
1.5"
2"
566
622
973
1056
799
876
1371
1482
1367
1490
2343
2519
2076
2254
3560
3814
h=3.06"

Gross Section Properties


Distance to
Moment of
N.A. from
Section
Inertia
Bottom
Modulus

Moment of
Inertia

Moment of
Inertia

Ie+
in4/ft
0.626
0.788
1.121
1.474

I ein4/ft
0.758
0.934
1.275
1.575

Bearing Length of Webs


3"
716
1194
1004
1669
1697
2816
2554
4239

1"
764
1303
1084
1844
1868
3173
2852
4849
r=0.125"

Composite and Non-Composite Deck Catalog May 2014

Uniform Load Only


Id = (2Ie+Ig)/3
I+
in4/ft
0.689
0.848
1.173
1.508

Factored (Rn)
1.5"
2"
866
952
1448
1570
1223
1340
2040
2205
2092
2280
3485
3748
3176
3449
5296
5673
=70.7

Iin4/ft
0.776
0.945
1.275
1.575

3"
1095
1776
1536
2482
2597
4189
3907
6305

www.ascsd.com

TABLE OF CONTENTS

3-7/8

4-1/8

8
3
36/5

2-1/8

32/5 Attachment Patterns

32

Panel Properties

Gage

Area
Ag
in2/ft
1.129
1.273
1.429
1.343
1.487
1.643
1.557
1.700
1.856

Effective Section Modulus at Fy


Bending
Distance to
N.A. from
Bottom
yb
in
0.80
0.75
0.66
1.00
0.91
0.83
1.13
1.04
0.96

Section
Modulus
Sein3/ft
0.710
0.802
0.837
0.907
1.045
1.087
1.104
1.280
1.332

Effective Moment of Inertia for Deflection


Distance to
N.A. from
Bottom
yb
in
1.60
1.46
1.31
1.62
1.52
1.39
1.64
1.56
1.45

Moment of
Inertia
Ie +
in4/ft
1.399
1.481
1.574
1.868
2.008
2.136
2.346
2.527
2.697

Moment of
Inertia
I ein4/ft
1.133
1.298
1.496
1.471
1.647
1.866
1.810
1.992
2.226

Uniform Load Only


Id = (2Ie+Ig)/3
I+
in4/ft
1.518
1.618
1.721
1.964
2.116
2.253
2.407
2.596
2.772

Iin4/ft
1.341
1.497
1.669
1.700
1.874
2.073
2.050
2.239
2.459

C PANELS

Section
Modulus
Se+
in3/ft
0.535
0.580
0.575
0.817
0.836
0.852
1.092
1.118
1.140

Radius of
Gyration
r
in
1.247
1.220
1.188
1.267
1.252
1.231
1.275
1.268
1.255

N PANELS

20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16

Area
Ae
in2/ft
0.902
0.970
1.073
1.279
1.343
1.444
1.636
1.711
1.820

Tensile
Strength
Fu
ksi
65
65
65
65
65
65
65
65
65

B PANELS

Compression

Base Metal
Thickness Yield Strength
t
Fy
in
ksi
0.0359 / 0.036
50
0.0359 / 0.047
50
0.0359 / 0.059
50
0.0478 / 0.036
50
0.0478 / 0.047
50
0.0478 / 0.059
50
0.0598 / 0.036
50
0.0598 / 0.047
50
0.0598 / 0.059
50

2W PANELS

20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16

Weight
w
psf
3.63
4.10
4.62
4.28
4.76
5.28
4.95
5.43
5.95

Gross Section Properties


Distance to
Moment of
N.A. from
Section
Inertia
Bottom
Modulus
Ig
yb
Sg
in4/ft
in
in3/ft
1.756
1.06
0.872
1.894
0.95
0.890
2.016
0.87
0.904
2.156
1.18
1.131
2.330
1.08
1.155
2.488
0.99
1.176
2.530
1.26
1.382
2.733
1.17
1.412
2.923
1.09
1.439

3W PANELS

NHF-32 Profile

Gage

GENERAL INFORMATION

NHF-32 5.2

D PANEL
ACUSTADEK

www.ascsd.com

Composite and Non-Composite Deck Catalog May 2014

125

TABLE OF CONTENTS

5.3 NHF-36 Cellular Composite Deck


Normal Weight Concrete (145 pcf)
Maximum Unshored Spans

NHF-36 Cellular Shoring Table


Total Slab Depth
(in)

Volume
cy/100sf

0.979

1.288

6 1/2
1 Hour
Fire Rating

1.442

7 1/2
2 Hour
Fire Rating

1.751

8 1/4
3 Hour
Fire Rating

1.982

Gage
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16

145 pcf Normal Weight Concrete


Maximum Unshored Span
Slab and Deck
psf
Single
Double
42.0
12' - 5"
14' - 8"
42.4
13' - 0"
15' - 2"
42.9
12' - 10"
15' - 1"
42.6
14' - 4"
16' - 7"
43.1
14' - 7"
17' - 7"
43.6
14' - 9"
18' - 0"
43.3
15' - 1"
18' - 0"
43.8
15' - 4"
18' - 4"
44.3
15' - 6"
18' - 9"
54.0
11' - 4"
13' - 5"
54.5
11' - 10"
13' - 11"
55.0
11' - 9"
13' - 10"
54.7
13' - 6"
15' - 3"
55.2
13' - 9"
16' - 4"
55.7
13' - 11"
16' - 7"
55.4
14' - 2"
16' - 9"
55.8
14' - 5"
17' - 4"
56.4
14' - 8"
17' - 8"
60.1
10' - 10"
12' - 11"
60.6
11' - 4"
13' - 5"
61.1
11' - 3"
13' - 4"
60.7
13' - 2"
14' - 8"
61.2
13' - 5"
15' - 9"
61.7
13' - 7"
16' - 0"
61.4
13' - 10"
16' - 2"
61.9
14' - 1"
16' - 11"
62.4
14' - 4"
17' - 3"
72.2
10' - 1"
12' - 1"
72.6
10' - 7"
12' - 7"
73.2
10' - 6"
12' - 6"
72.8
12' - 8"
13' - 9"
73.3
12' - 10"
14' - 9"
73.8
13' - 0"
15' - 0"
73.5
13' - 3"
15' - 1"
74.0
13' - 6"
16' - 2"
74.5
13' - 8"
16' - 6"
81.2
9' - 7"
11' - 7"
81.7
10' - 1"
12' - 0"
82.2
10' - 0"
11' - 11"
81.9
12' - 3"
13' - 2"
82.4
12' - 4"
14' - 1"
82.9
12' - 5"
14' - 4"
82.6
12' - 11"
14' - 5"
83.0
13' - 2"
15' - 6"
83.5
13' - 4"
15' - 10"

Triple
13' - 3"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
12' - 2"
12' - 8"
12' - 6"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
11' - 9"
12' - 2"
12' - 1"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
10' - 11"
11' - 4"
11' - 3"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
10' - 6"
10' - 10"
10' - 10"
12' - 11"
13' - 0"
13' - 1"
13' - 4"
13' - 4"
13' - 4"

Shaded area the span is governed by maximum deck panel length of 40 feet; 20 feet for double span, 13 feet 4 inches for triple span.

126

Composite and Non-Composite Deck Catalog May 2014

www.ascsd.com

TABLE OF CONTENTS

NHF-36 Cellular Composite Deck 5.3


Light Weight Concrete (110 pcf)
Maximum Unshored Spans

Volume
cy/100sf

0.979

1 Hour
Fire Rating

1.288

2 Hour
Fire Rating

1.365

3 Hour
Fire Rating

1.654

D PANEL

7 3/16

C PANELS

6 1/4

N PANELS

1.133

Triple
13' - 4"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
13' - 2"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
12' - 4"
12' - 10"
12' - 9"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
13' - 4"
13' - 4"

B PANELS

5 1/2

ACUSTADEK

Gage
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16

110 pcf Light Weight Concrete


Maximum Unshored Span
Slab and Deck
psf
Single
Double
32.7
13' - 9"
15' - 11"
33.2
14' - 5"
16' - 7"
33.7
14' - 3"
16' - 5"
33.4
15' - 4"
18' - 1"
33.8
15' - 6"
18' - 9"
34.4
15' - 9"
19' - 2"
34.0
16' - 0"
19' - 2"
34.5
16' - 3"
19' - 6"
35.0
16' - 6"
19' - 11"
37.3
13' - 1"
15' - 4"
37.8
13' - 8"
15' - 11"
38.3
13' - 7"
15' - 9"
37.9
14' - 10"
17' - 5"
38.4
15' - 1"
18' - 3"
38.9
15' - 3"
18' - 7"
38.6
15' - 7"
18' - 7"
39.1
15' - 10"
19' - 0"
39.6
16' - 0"
19' - 4"
41.9
12' - 7"
14' - 9"
42.3
13' - 1"
15' - 4"
42.9
13' - 0"
15' - 2"
42.5
14' - 5"
16' - 9"
43.0
14' - 8"
17' - 9"
43.5
14' - 10"
18' - 2"
43.2
15' - 2"
18' - 1"
43.7
15' - 5"
18' - 6"
44.2
15' - 7"
18' - 10"
44.2
12' - 4"
14' - 6"
44.6
12' - 10"
15' - 0"
45.2
12' - 9"
14' - 11"
44.8
14' - 3"
16' - 6"
45.3
14' - 6"
17' - 6"
45.8
14' - 8"
17' - 11"
45.5
14' - 11"
17' - 11"
46.0
15' - 2"
18' - 3"
46.5
15' - 5"
18' - 7"
52.8
11' - 6"
13' - 8"
53.2
12' - 0"
14' - 2"
53.7
11' - 11"
14' - 1"
53.4
13' - 8"
15' - 6"
53.9
13' - 11"
16' - 7"
54.4
14' - 1"
16' - 10"
54.1
14' - 4"
17' - 0"
54.6
14' - 7"
17' - 6"
55.1
14' - 9"
17' - 11"

2W PANELS

Total Slab Depth


(in)

3W PANELS

NHF-36 Cellular Shoring Table

Shaded area the span is governed by maximum deck panel length of 40 feet; 20 feet for double span, 13 feet 4 inches for triple span.

www.ascsd.com

GENERAL INFORMATION

Composite and Non-Composite Deck Catalog May 2014

127

TABLE OF CONTENTS

5.3 NH-32 Composite Deck


5" Total Slab Depth
Normal Weight Concrete (145 pcf)

Concrete Volume 0.979yd3/100ft2

Gage
22
20

GA

22

Single
9' - 7"
11' - 2"

9'-0"

9'-6"

ASD, W/
LRFD, W
L/360

212
339
-

187
299
-

2315
2149
2136
2124
41.0
65.45

2306
2149
2136
2125
psf
in4/ft

9'-0"

9'-6"

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"
Concrete + Deck =
(Icr+Iu)/2 =

Single
12' - 8"
13' - 3"

Double
14' - 10"
16' - 6"

166
265
-

148
236
-

132
211
-

118
189
-

106
169
-

95
152
-

86
137
-

2287
2138
2126
2116

2271
2128
2117
2107
Icr =
Iu =

2255 2241
2119 2111
2109 2101
2099 2092
38.1 in4/ft
92.8 in4/ft

2228
2104
2094
2085

2225
2105
2096
2088

2214
2099
2090
2082
Mno/=
Mno=

77
123
-

LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern

9'-0"

2203 2194
2093 2087
2084 2079
2076 2071
30.8 kip-in/ft
47.2 kip-in/ft

9'-6"

9'-6"

70
111
-

10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6"


ASD & LRFD - Superimposed Load, W (psf)
402 358 320 287 259 234 212 193 176 160
ASD, W/
644 573 512 459 414 375 340 309 282 258
LRFD, W
L/360
160
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
2754 2754 2712 2673 2638 2606 2577 2584 2558 2534
PAF Base Steel .25"
2396 2416 2390 2367 2346 2326 2309 2327 2311 2295
PAF Base Steel 0.109"
2357 2379 2355 2333 2314 2296 2280 2299 2284 2270
#12 Screw Base Steel .034"
2370 2391 2367 2346 2326 2308 2292 2311 2296 2282
Concrete + Deck = 42.8 psf
Icr = 61.6 in4/ft
Mno/= 55.2
(Icr+Iu)/2 = 83.94 in4/ft
Iu = 106.3 in4/ft
Mno= 84.5

63
100
-

57
91
-

2185
2082
2074
2066

2176
2077
2069
2062
Vn/ =
Vn =

51
82
-

46
74
-

2175 2168
2079 2074
2071 2067
2064 2060
3.12 kip/ft
4.67 kip/ft

14'-0" 14'-6" 15'-0" 15'-6" 16'-0"


86
138
-

78
125
-

71
114
-

2251
2120
2110
2102
kip-in/ft
kip-in/ft

2239
2114
2104
2096

2229
2107
2098
2090
Vn/ =
Vn =

65
104
-

59
94
-

2229 2220
2112 2106
2103 2097
2095 2090
3.12 kip/ft
4.67 kip/ft

14'-0" 14'-6" 15'-0" 15'-6" 16'-0"


117
188
-

107
172
-

98
157
-

2374
2195
2182
2173
kip-in/ft
kip-in/ft

2358
2185
2173
2164

2343
2176
2164
2156
Vn/ =
Vn =

90
144
-

83
132
-

2347 2333
2186 2177
2174 2166
2166 2158
3.12 kip/ft
4.67 kip/ft

14'-0" 14'-6" 15'-0" 15'-6" 16'-0"


143
236
143

129
217
129

116
199
116

2511
2281
2256
2269
kip-in/ft
kip-in/ft

2490
2268
2244
2256

2471
2256
2233
2245
Vn/ =
Vn =

105
183
105

96
169
96

2480 2462
2273 2261
2250 2239
2262 2251
3.12 kip/ft
4.67 kip/ft

All Gages

9'-0"

Triple
15' - 2"
15' - 11"

10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" 15'-6" 16'-0"

ASD & LRFD - Superimposed Load, W (psf)

10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6"


ASD & LRFD - Superimposed Load, W (psf)
329
292 260 233 210 189 171 155 141 129
ASD, W/
526
467 417 373 336 303 274 248 226 206
LRFD, W
L/360
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
2567 2562 2530 2500 2474 2449 2427 2429 2409 2391
PAF Base Steel .25"
2290 2299 2280 2262 2246 2232 2219 2229 2217 2205
PAF Base Steel 0.109"
2269 2280 2261 2245 2230 2216 2204 2214 2203 2192
#12 Screw Base Steel .034"
2255 2266 2249 2233 2218 2205 2193 2204 2193 2183
Concrete + Deck = 42.0 psf
Icr = 52.9 in4/ft
Mno/= 45.8
(Icr+Iu)/2 = 77.02 in4/ft
Iu = 101.1 in4/ft
Mno= 70.1
Vertical Load Span (in)

16

Gage
18
16

10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6"


ASD & LRFD - Superimposed Load, W (psf)
253
224 199 178 159 143 129
116
105
95
ASD, W/
405
358 318 284 255 229 206 186 168 152
LRFD, W
L/360
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
2396 2388 2365 2344 2325 2308 2292 2289 2275 2263
PAF Base Steel .25"
2194 2196 2182 2170 2159 2149 2140 2144 2135 2128
PAF Base Steel 0.109"
2178 2181 2169 2157 2147 2137 2128 2132 2125 2117
#12 Screw Base Steel .034"
2165 2169 2157 2146 2136 2127 2118 2123 2116 2109
Concrete + Deck = 41.3 psf
Icr = 43.5 in4/ft
Mno/= 36.1
4
(Icr+Iu)/2 = 69.59 in /ft
Iu = 95.7 in4/ft
Mno= 55.2
Vertical Load Span (in)

18

Triple
11' - 4"
12' - 11"

Vertical Load Span (in)

Vertical Load Span (in)

20

Maximum Unshored Span (in)

Double
10' - 9"
12' - 6"

LRFD - Diaphragm Shear, Sn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4
6x6 W2.9xW2.9
6x6 W4.0xW4.0
4x4 W4xW4
4x4 W6xW6
3/4" Welded Shear Studs
As = 0.028 in2/ft
As = 0.058 in2/ft
As = 0.080 in2/ft
As = 0.120 in2/ft
As = 0.180 in2/ft
8 in o.c.
3200
4550
5540
7340
10040
16 in o.c.
3200
4550
5540
7340
9890
24 in o.c.
3200
4550
5540
6590
6590

128

Composite and Non-Composite Deck Catalog May 2014

www.ascsd.com

TABLE OF CONTENTS

NH-32 Composite Deck 5.3


512" Total Slab Depth
Normal Weight Concrete (145 pcf)



Gage
22
20

22

9'-0"

9'-6"

ASD, W/
LRFD, W
L/360

252
402
-

222
355
-

Double
14' - 2"
16' - 0"

10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" 15'-6" 16'-0"

ASD & LRFD - Superimposed Load, W (psf)


197
315
-

175
281
-

157
251
-

140
225
-

126
202
-

113
181
-

102
163
-

2778
2628
2617
2606

2761
2619
2607
2597
Icr =
Iu =

2746
2610
2599
2589
49.7
122.6

2732
2602
2591
2582
in4/ft
in4/ft

2719
2594
2584
2575

2715
2596
2587
2578

2704
2589
2580
2572
Mno/=
Mno=

92
147
-

LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern

2805 2797
2639 2639
2626 2627
2614 2616
47.1 psf
86.2 in4/ft
9'-0"

9'-0"

9'-6"

9'-6"

68
109
-

2675
2572
2564
2557

2667
2567
2559
2552
Vn/ =
Vn =

61
98
-

55
89
-

2666 2658
2569 2565
2562 2557
2555 2551
3.58 kip/ft
5.37 kip/ft

14'-0" 14'-6" 15'-0" 15'-6" 16'-0"


103
165
-

94
150
-

85
137
-

2741
2611
2601
2592
kip-in/ft
kip-in/ft

2730
2604
2595
2586

2719
2598
2589
2581
Vn/ =
Vn =

78
124
-

71
113
-

2720 2710
2602 2596
2593 2588
2585 2580
3.58 kip/ft
5.37 kip/ft

14'-0" 14'-6" 15'-0" 15'-6" 16'-0"


140
225
-

128
205
-

118
188
-

2864
2685
2672
2663
kip-in/ft
kip-in/ft

2848
2676
2663
2654

2833
2667
2655
2646
Vn/ =
Vn =

108
173
-

99
158
-

2837 2824
2676 2668
2664 2656
2656 2648
3.58 kip/ft
5.37 kip/ft

14'-0" 14'-6" 15'-0" 15'-6" 16'-0"


162
259
-

149
238
-

3002
2772
2747
2759
kip-in/ft
kip-in/ft

2981
2759
2735
2747

2961
2747
2723
2735
Vn/ =
Vn =

137
219
-

126
202
126

2971 2953
2763 2751
2740 2730
2752 2742
3.58 kip/ft
5.37 kip/ft

www.ascsd.com

Composite and Non-Composite Deck Catalog May 2014

129

ACUSTADEK

LRFD - Diaphragm Shear, Sn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4
6x6 W2.9xW2.9
6x6 W4.0xW4.0
4x4 W4xW4
4x4 W6xW6
3/4" Welded Shear Studs
As = 0.028 in2/ft
As = 0.058 in2/ft
As = 0.080 in2/ft
As = 0.120 in2/ft
As = 0.180 in2/ft
8 in o.c.
3690
5040
6030
7830
10530
16 in o.c.
3690
5040
6030
7830
9890
24 in o.c.
3690
5040
6030
6590
6590

D PANEL

176
282
-

C PANELS

10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6"


ASD & LRFD - Superimposed Load, W (psf)
478 426 381 342 308 279 253 230 210 192
ASD, W/
766 681 609 547 493 446 405 369 336 308
LRFD, W
L/360
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
3244 3245 3202 3164 3129 3097 3067 3075 3049 3024
PAF Base Steel .25"
2887 2906 2880 2857 2836 2817 2799 2817 2801 2786
PAF Base Steel 0.109"
2848 2869 2845 2824 2804 2786 2770 2789 2774 2760
#12 Screw Base Steel .034"
2860 2881 2858 2836 2816 2799 2782 2801 2786 2772
Concrete + Deck = 48.9 psf
Icr = 80.4 in4/ft
Mno/= 65.5
(Icr+Iu)/2 = 110 in4/ft
Iu = 139.7 in4/ft
Mno= 100.2

75
120
-

N PANELS

9'-6"

83
133
-

2694 2684
2583 2577
2574 2569
2566 2561
36.4 kip-in/ft
55.8 kip-in/ft

10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6"


ASD & LRFD - Superimposed Load, W (psf)
391
347 310 278 250 225 204 185 169 154
ASD, W/
625
555 496 444 400 361 326 296 270 246
LRFD, W
L/360
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
3058 3052 3020 2991 2964 2940 2918 2919 2899 2881
PAF Base Steel .25"
2780 2789 2770 2753 2737 2722 2709 2719 2707 2696
PAF Base Steel 0.109"
2760 2770 2752 2735 2720 2707 2694 2704 2693 2682
#12 Screw Base Steel .034"
2746 2757 2739 2723 2709 2696 2684 2694 2683 2673
Concrete + Deck = 48.2 psf
Icr = 69.1 in4/ft
Mno/= 54.3
(Icr+Iu)/2 = 101 in4/ft
Iu = 133.2 in4/ft
Mno= 83.0
9'-0"

Triple
14' - 8"
15' - 5"

B PANELS

All Gages

Single
12' - 3"
12' - 10"

10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6"


ASD & LRFD - Superimposed Load, W (psf)
300
266 237
211
189 170 153 139 125
114
ASD, W/
481
426 379 338 303 272 245 222 201 182
LRFD, W
L/360
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
2887 2878 2855 2834 2815 2798 2782 2780 2766 2753
PAF Base Steel .25"
2684 2686 2673 2661 2650 2639 2630 2634 2626 2618
PAF Base Steel 0.109"
2669 2672 2659 2647 2637 2627 2619 2623 2615 2608
#12 Screw Base Steel .034"
2656 2659 2647 2636 2626 2617 2609 2614 2606 2599
Concrete + Deck = 47.5 psf
Icr = 56.7 in4/ft
Mno/= 42.7
4
(Icr+Iu)/2 = 91.5 in /ft
Iu = 126.3 in4/ft
Mno= 65.3

Vertical Load Span (in)

16

Gage
18
16

2W PANELS

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"
Concrete + Deck =
(Icr+Iu)/2 =

Vertical Load Span (in)

18

Triple
10' - 9"
12' - 4"

Vertical Load Span (in)

Vertical Load Span (in)

20

Maximum Unshored Span (in)

Double
10' - 4"
12' - 0"

3W PANELS

GA

Single
9' - 2"
10' - 8"

Concrete Volume 1.133yd3/100ft2

GENERAL INFORMATION

TABLE OF CONTENTS

5.3 NH-32 Composite Deck


6" Total Slab Depth
Normal Weight Concrete (145 pcf)

Concrete Volume 1.288yd3/100ft2

Gage
22
20

GA

22

Single
8' - 9"
10' - 2"

9'-0"

9'-6"

ASD, W/
LRFD, W
L/360

294
470
-

260
415
-

3296
3130
3117
3105
53.3
110.9

3287
3130
3117
3106
psf
in4/ft

9'-0"

9'-6"

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"
Concrete + Deck =
(Icr+Iu)/2 =

All Gages

130

Single
11' - 11"
12' - 6"

Double
13' - 7"
15' - 5"

230
369
-

205
328
-

183
294
-

164
263
-

148
236
-

133
213
-

120
192
-

3268
3119
3107
3096

3251
3109
3098
3088
Icr =
Iu =

3236
3100
3090
3080
63.3
158.6

3222
3092
3082
3073
in4/ft
in4/ft

3209
3085
3075
3066

3206
3086
3077
3068

3195
3080
3071
3062
Mno/=
Mno=

108
173
-

LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern

9'-0"

9'-0"

Triple
14' - 0"
15' - 0"

10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" 15'-6" 16'-0"

ASD & LRFD - Superimposed Load, W (psf)

9'-6"

9'-6"

98
157
-

3184 3175
3073 3068
3065 3059
3057 3052
42.4 kip-in/ft
64.9 kip-in/ft

10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6"


ASD & LRFD - Superimposed Load, W (psf)
457
406 363 325 293 264 239 218 198 181
ASD, W/
732
650 580 520 468 423 383 348 317 289
LRFD, W
L/360
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
3548 3543 3510 3481 3455 3430 3408 3409 3390 3371
PAF Base Steel .25"
3271 3280 3261 3243 3227 3213 3200 3209 3197 3186
PAF Base Steel 0.109"
3250 3261 3242 3226 3211 3197 3185 3195 3183 3173
#12 Screw Base Steel .034"
3236 3247 3230 3214 3199 3186 3174 3185 3174 3163
Concrete + Deck = 54.4 psf
Icr = 88.3 in4/ft
Mno/= 63.3
(Icr+Iu)/2 = 130 in4/ft
Iu = 171.7 in4/ft
Mno= 96.9
Vertical Load Span (in)

16

Gage
18
16

10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6"


ASD & LRFD - Superimposed Load, W (psf)
351
311
277 247 222 199 180 163 147 134
ASD, W/
562
498 443 396 355 319 288 260 236 214
LRFD, W
L/360
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
3377 3369 3346 3325 3306 3288 3272 3270 3256 3243
PAF Base Steel .25"
3174 3177 3163 3151 3140 3130 3121 3124 3116 3108
PAF Base Steel 0.109"
3159 3162 3149 3138 3127 3118 3109 3113 3105 3098
#12 Screw Base Steel .034"
3146 3150 3138 3127 3117 3108 3099 3104 3096 3089
Concrete + Deck = 53.7 psf
Icr = 72.4 in4/ft
Mno/= 49.7
4
(Icr+Iu)/2 = 117.8 in /ft
Iu = 163.2 in4/ft
Mno= 76.1
Vertical Load Span (in)

18

Triple
10' - 4"
11' - 10"

Vertical Load Span (in)

Vertical Load Span (in)

20

Maximum Unshored Span (in)

Double
9' - 11"
11' - 6"

10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6"


ASD & LRFD - Superimposed Load, W (psf)
560 499 446 401 362 327 297 271 247 226
ASD, W/
897 798 714 641 578 524 475 433 395 362
LRFD, W
L/360
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
3735 3735 3693 3654 3619 3587 3558 3565 3539 3515
PAF Base Steel .25"
3377 3396 3371 3348 3326 3307 3290 3308 3291 3276
PAF Base Steel 0.109"
3338 3360 3336 3314 3295 3277 3260 3280 3265 3250
#12 Screw Base Steel .034"
3351 3372 3348 3326 3307 3289 3273 3292 3277 3262
Concrete + Deck = 55.1 psf
Icr = 102.7 in4/ft
Mno/= 76.5
(Icr+Iu)/2 = 141.4 in4/ft
Iu = 180.0 in4/ft
Mno= 117.0

89
142
-

80
128
-

3165
3062
3054
3047

3157
3057
3050
3043
Vn/ =
Vn =

73
116
-

66
105
-

3156 3149
3060 3055
3052 3048
3045 3041
4.07 kip/ft
6.10 kip/ft

14'-0" 14'-6" 15'-0" 15'-6" 16'-0"


121
194
-

111
177
-

101
161
-

3231
3101
3091
3083
kip-in/ft
kip-in/ft

3220
3095
3085
3077

3210
3088
3079
3071
Vn/ =
Vn =

92
147
-

84
134
-

3210 3201
3092 3087
3083 3078
3076 3071
4.07 kip/ft
6.10 kip/ft

14'-0" 14'-6" 15'-0" 15'-6" 16'-0"


165
264
-

151
242
-

139
222
-

3354
3176
3163
3154
kip-in/ft
kip-in/ft

3339
3166
3154
3145

3324
3157
3145
3137
Vn/ =
Vn =

127
204
-

117
187
-

3328 3314
3166 3158
3155 3147
3147 3139
4.07 kip/ft
6.10 kip/ft

14'-0" 14'-6" 15'-0" 15'-6" 16'-0"


207
332
-

191
305
-

175
281
-

3492
3262
3237
3249
kip-in/ft
kip-in/ft

3471
3249
3225
3237

3452
3237
3214
3226
Vn/ =
Vn =

162
259
-

149
239
-

3461 3443
3253 3242
3231 3220
3243 3232
4.07 kip/ft
6.10 kip/ft

LRFD - Diaphragm Shear, Sn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4
6x6 W2.9xW2.9
6x6 W4.0xW4.0
4x4 W4xW4
4x4 W6xW6
3/4" Welded Shear Studs
As = 0.028 in2/ft
As = 0.058 in2/ft
As = 0.080 in2/ft
As = 0.120 in2/ft
As = 0.180 in2/ft
8 in o.c.
4180
5530
6520
8320
11020
16 in o.c.
4180
5530
6520
8320
9890
24 in o.c.
4180
5530
6520
6590
6590

Composite and Non-Composite Deck Catalog May 2014

www.ascsd.com

TABLE OF CONTENTS

NH-32 Composite Deck 5.3


6 12" Total Slab Depth
Normal Weight Concrete (145 pcf)

Concrete Volume 1.442yd3/100ft2


1 Hour Fire Rating


Gage
22
20

22

9'-6"

ASD, W/
LRFD, W
L/360

338
541
-

299
478
-

3786
3620
3607
3595
59.5
140.2

3777
3620
3608
3597
psf
in4/ft

9'-0"

9'-6"

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"
Concrete + Deck =
(Icr+Iu)/2 =

Double
13' - 1"
14' - 10"

10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" 15'-6" 16'-0"

ASD & LRFD - Superimposed Load, W (psf)


265
425
-

237
378
-

212
339
-

190
304
-

171
273
-

154
246
-

139
222
-

3759
3609
3598
3587

3742
3599
3588
3578
Icr =
Iu =

3726
3591
3580
3570
79.0
201.5

3712
3582
3572
3563
in4/ft
in4/ft

3700
3575
3565
3556

3696
3577
3567
3559

3685
3570
3561
3553
Mno/=
Mno=

125
201
-

LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern

9'-0"

9'-6"

93
149
-

3656
3553
3545
3537

3648
3548
3540
3533
Vn/ =
Vn =

84
135
-

76
122
-

3647 3639
3550 3546
3543 3538
3536 3532
4.58 kip/ft
6.74 kip/ft

14'-0" 14'-6" 15'-0" 15'-6" 16'-0"


141
225
-

128
205
-

117
187
-

3722
3592
3582
3573
kip-in/ft
kip-in/ft

3711
3585
3575
3567

3700
3579
3569
3562
Vn/ =
Vn =

107
171
-

97
156
-

3700 3691
3583 3577
3574 3568
3566 3561
4.58 kip/ft
6.88 kip/ft

14'-0" 14'-6" 15'-0" 15'-6" 16'-0"


191
306
-

175
281
-

161
257
-

3845
3666
3653
3644
kip-in/ft
kip-in/ft

3829
3657
3644
3635

3814
3648
3635
3627
Vn/ =
Vn =

148
236
-

136
217
-

3818 3805
3657 3648
3645 3637
3637 3629
4.58 kip/ft
6.88 kip/ft

14'-0" 14'-6" 15'-0" 15'-6" 16'-0"


221
354
-

204
326
-

3983
3753
3728
3740
kip-in/ft
kip-in/ft

3962
3740
3716
3728

3942
3728
3704
3716
Vn/ =
Vn =

188
300
-

173
277
-

3951 3933
3744 3732
3721 3710
3733 3722
4.58 kip/ft
6.88 kip/ft

www.ascsd.com

Composite and Non-Composite Deck Catalog May 2014

131

ACUSTADEK

LRFD - Diaphragm Shear, Sn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4
6x6 W2.9xW2.9
6x6 W4.0xW4.0
4x4 W4xW4
4x4 W6xW6
3/4" Welded Shear Studs
As = 0.028 in2/ft
As = 0.058 in2/ft
As = 0.080 in2/ft
As = 0.120 in2/ft
As = 0.180 in2/ft
8 in o.c.
n/a
6030
7020
8820
11520
16 in o.c.
n/a
6030
7020
8820
9890
24 in o.c.
n/a
6030
6590
6590
6590

D PANEL

240
385
-

C PANELS

10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6"


ASD & LRFD - Superimposed Load, W (psf)
647 576 515 463 418 379 344 313 286 262
ASD, W/
1035 922 825 741 669 606 550 501 458 419
LRFD, W
L/360
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
4225 4226 4183 4145 4110 4078 4048 4056 4029 4005
PAF Base Steel .25"
3868 3887 3861 3838 3817 3798 3780 3798 3782 3767
PAF Base Steel 0.109"
3829 3850 3826 3805 3785 3767 3751 3770 3755 3741
#12 Screw Base Steel .034"
3841 3862 3838 3817 3797 3779 3763 3782 3767 3753
Concrete + Deck = 61.3 psf
Icr = 128.7 in4/ft
Mno/= 88.1
(Icr+Iu)/2 = 178.3 in4/ft
Iu = 227.8 in4/ft
Mno= 134.7

103
165
-

N PANELS

9'-6"

114
182
-

3675 3665
3564 3558
3555 3550
3547 3542
48.6 kip-in/ft
74.4 kip-in/ft

10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6"


ASD & LRFD - Superimposed Load, W (psf)
528
469 419 376 338 306 277 252 229 209
ASD, W/
844
750 670 601 541 489 443 403 367 335
LRFD, W
L/360
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
4039 4033 4001 3972 3945 3921 3898 3900 3880 3862
PAF Base Steel .25"
3761 3770 3751 3734 3718 3703 3690 3700 3688 3677
PAF Base Steel 0.109"
3741 3751 3733 3716 3701 3688 3675 3685 3674 3663
#12 Screw Base Steel .034"
3727 3738 3720 3704 3690 3677 3664 3675 3664 3654
Concrete + Deck = 60.5 psf
Icr = 110.5 in4/ft
Mno/= 72.8
4
(Icr+Iu)/2 = 164.1 in /ft
Iu = 217.7 in4/ft
Mno= 111.4
9'-0"

Triple
13' - 6"
14' - 7"

B PANELS

All Gages

Single
11' - 7"
12' - 2"

10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6"


ASD & LRFD - Superimposed Load, W (psf)
404
358 319 285 256 230 208 188 170 155
ASD, W/
647
573 510 456 409 368 333 301 273 248
LRFD, W
L/360
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
3867 3859 3836 3815 3796 3779 3763 3761 3747 3734
PAF Base Steel .25"
3665 3667 3654 3641 3630 3620 3611 3615 3607 3599
PAF Base Steel 0.109"
3650 3653 3640 3628 3618 3608 3599 3604 3596 3589
#12 Screw Base Steel .034"
3637 3640 3628 3617 3607 3598 3590 3594 3587 3580
Concrete + Deck = 59.8 psf
Icr = 90.4 in4/ft
Mno/= 57.1
(Icr+Iu)/2 = 148.8 in4/ft
Iu = 207.1 in4/ft
Mno= 87.3

Vertical Load Span (in)

16

Gage
18
16

2W PANELS

9'-0"

Vertical Load Span (in)

18

Triple
9' - 11"
11' - 5"

Vertical Load Span (in)

Vertical Load Span (in)

20

Maximum Unshored Span (in)

Double
9' - 6"
11' - 0"

3W PANELS

GA

Single
8' - 5"
9' - 9"

GENERAL INFORMATION

TABLE OF CONTENTS

5.3 NH-32 Composite Deck

7 12" Total Slab Depth


Normal Weight Concrete (145 pcf)
Concrete Volume 1.751yd3/100ft2
2 Hour Fire Rating
Gage
22
20

GA

22

Single
7' - 10"
9' - 1"

9'-0"

9'-6"

ASD, W/
LRFD, W
L/360

431
690
-

382
610
-

4767
4601
4588
4576
71.8
213.9

4758
4601
4589
4577
psf
in4/ft

9'-0"

9'-6"

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"
Concrete + Deck =
(Icr+Iu)/2 =

Single
11' - 1"
11' - 8"

Double
12' - 2"
13' - 10"

339
543
-

303
484
-

271
433
-

243
389
-

219
350
-

198
316
-

179
286
-

4740
4590
4578
4568

4723
4580
4569
4559
Icr =
Iu =

4707
4571
4561
4551
116.8
311.1

4693
4563
4553
4544
in4/ft
in4/ft

4680
4556
4546
4537

4677
4558
4548
4540

4666
4551
4542
4534
Mno/=
Mno=

162
259
-

LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern

9'-0"

4655 4646
4545 4539
4536 4531
4528 4523
61.6 kip-in/ft
94.3 kip-in/ft

9'-6"

9'-6"

147
235
-

10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6"


ASD & LRFD - Superimposed Load, W (psf)
831 740 663 596 538 488 443 404 370 339
ASD, W/
1330 1184 1060 953 861 780 709 647 591 542
LRFD, W
L/360
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
5206 5206 5164 5125 5090 5058 5029 5036 5010 4986
PAF Base Steel .25"
4848 4868 4842 4819 4798 4779 4761 4779 4763 4748
PAF Base Steel 0.109"
4810 4831 4807 4786 4766 4748 4732 4751 4736 4722
#12 Screw Base Steel .034"
4822 4843 4819 4798 4778 4760 4744 4763 4748 4734
Concrete + Deck = 73.6 psf
Icr = 192.0 in4/ft
Mno/= 112.6
(Icr+Iu)/2 = 270.6 in4/ft
Iu = 349.2 in4/ft
Mno= 172.3

133
213
-

121
193
-

4637
4534
4526
4518

4628
4529
4521
4514
Vn/ =
Vn =

110
176
-

100
159
-

4627 4620
4531 4526
4523 4519
4517 4512
5.28 kip/ft
7.58 kip/ft

14'-0" 14'-6" 15'-0" 15'-6" 16'-0"


182
291
-

166
265
-

151
242
-

4703
4572
4563
4554
kip-in/ft
kip-in/ft

4691
4566
4556
4548

4681
4560
4550
4543
Vn/ =
Vn =

138
221
-

126
202
-

4681 4672
4564 4558
4555 4549
4547 4542
5.70 kip/ft
8.55 kip/ft

14'-0" 14'-6" 15'-0" 15'-6" 16'-0"


247
396
-

227
363
-

208
333
-

4826
4647
4634
4625
kip-in/ft
kip-in/ft

4810
4637
4625
4616

4795
4628
4616
4608
Vn/ =
Vn =

192
307
-

177
282
-

4799 4785
4638 4629
4626 4618
4618 4610
5.70 kip/ft
8.55 kip/ft

14'-0" 14'-6" 15'-0" 15'-6" 16'-0"


311
498
-

286
458
-

264
422
-

4963
4734
4709
4721
kip-in/ft
kip-in/ft

4943
4721
4696
4708

4923
4708
4685
4697
Vn/ =
Vn =

244
390
-

225
360
-

4932 4914
4725 4713
4702 4691
4714 4703
5.70 kip/ft
8.55 kip/ft

All Gages

9'-0"

Triple
12' - 7"
14' - 0"

10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" 15'-6" 16'-0"

ASD & LRFD - Superimposed Load, W (psf)

10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6"


ASD & LRFD - Superimposed Load, W (psf)
676
601 537 482 434 393 356 324 296 270
ASD, W/
1082 962 860 771 695 629 570 519 473 432
LRFD, W
L/360
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
5020 5014 4982 4952 4926 4902 4879 4881 4861 4843
PAF Base Steel .25"
4742 4751 4732 4714 4699 4684 4671 4681 4669 4658
PAF Base Steel 0.109"
4722 4732 4714 4697 4682 4668 4656 4666 4655 4644
#12 Screw Base Steel .034"
4708 4719 4701 4685 4671 4657 4645 4656 4645 4635
Concrete + Deck = 72.9 psf
Icr = 164.3 in4/ft
Mno/= 92.8
4
(Icr+Iu)/2 = 249.4 in /ft
Iu = 334.5 in4/ft
Mno= 142.0
Vertical Load Span (in)

16

Gage
18
16

10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6"


ASD & LRFD - Superimposed Load, W (psf)
516
458 408 365 328 295 267 242 219 199
ASD, W/
826
733 653 584 525 473 427 387 351 319
LRFD, W
L/360
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
4848 4840 4817 4796 4777 4760 4744 4742 4728 4715
PAF Base Steel .25"
4646 4648 4635 4622 4611 4601 4592 4596 4587 4580
PAF Base Steel 0.109"
4630 4633 4621 4609 4599 4589 4580 4585 4577 4569
#12 Screw Base Steel .034"
4617 4621 4609 4598 4588 4579 4571 4575 4568 4561
Concrete + Deck = 72.1 psf
Icr = 133.9 in4/ft
Mno/= 72.5
(Icr+Iu)/2 = 226.6 in4/ft
Iu = 319.2 in4/ft
Mno= 110.9
Vertical Load Span (in)

18

Triple
9' - 2"
10' - 7"

Vertical Load Span (in)

Vertical Load Span (in)

20

Maximum Unshored Span (in)

Double
8' - 11"
10' - 4"

LRFD - Diaphragm Shear, Sn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4
6x6 W2.9xW2.9
6x6 W4.0xW4.0
4x4 W4xW4
4x4 W6xW6
3/4" Welded Shear Studs
As = 0.028 in2/ft
As = 0.058 in2/ft
As = 0.080 in2/ft
As = 0.120 in2/ft
As = 0.180 in2/ft
8 in o.c.
n/a
7010
8000
9800
12500
16 in o.c.
n/a
7010
8000
9800
9890
24 in o.c.
n/a
6590
6590
6590
6590

132

Composite and Non-Composite Deck Catalog May 2014

www.ascsd.com

TABLE OF CONTENTS

NH-32 Composite Deck 5.3


8 14" Total Slab Depth
Normal Weight Concrete (145 pcf)

Concrete Volume 1.982yd3/100ft2


3 Hour Fire Rating


Gage
22
20

22

9'-6"

ASD, W/
LRFD, W
L/360

504
807
-

446
714
-

5503
5337
5324
5312
81.0
283.9

5494
5337
5324
5313
psf
in4/ft

9'-0"

9'-6"

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"
Concrete + Deck =
(Icr+Iu)/2 =

Double
11' - 8"
13' - 3"

10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" 15'-6" 16'-0"

ASD & LRFD - Superimposed Load, W (psf)


397
635
-

354
567
-

317
508
-

285
456
-

257
411
-

232
371
-

210
336
-

190
304
-

173
276
-

157
251
-

143
228
-

5475
5326
5314
5303

5458
5316
5305
5295
Icr =
Iu =

5443
5307
5296
5287
150.7
417.2

5429
5299
5289
5280
in4/ft
in4/ft

5416
5291
5282
5273

5413
5293
5284
5275

5402
5287
5278
5269
Mno/=
Mno=

5391
5280
5272
5264
71.8
109.8

5381
5275
5266
5259
kip-in/ft
kip-in/ft

5372
5269
5261
5254

5364
5264
5257
5249
Vn/ =
Vn =

LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern

9'-0"

9'-6"

5363 5355
5267 5262
5259 5255
5252 5248
5.73 kip/ft
8.26 kip/ft

14'-0" 14'-6" 15'-0" 15'-6" 16'-0"


214
342
-

195
312
-

178
286
-

5438
5308
5298
5290
kip-in/ft
kip-in/ft

5427
5301
5292
5284

5417
5295
5286
5278
Vn/ =
Vn =

163
261
-

149
239
-

5417 5407
5299 5294
5290 5285
5283 5278
6.61 kip/ft
9.91 kip/ft

14'-0" 14'-6" 15'-0" 15'-6" 16'-0"


291
466
-

267
428
-

246
393
-

5561
5383
5370
5361
kip-in/ft
kip-in/ft

5546
5373
5361
5352

5531
5364
5352
5344
Vn/ =
Vn =

226
362
-

209
334
-

5535 5521
5373 5365
5362 5354
5353 5346
6.61 kip/ft
9.91 kip/ft

14'-0" 14'-6" 15'-0" 15'-6" 16'-0"


367
587
-

338
540
-

311
498
-

5699
5469
5444
5456
kip-in/ft
kip-in/ft

5678
5456
5432
5444

5659
5444
5421
5433
Vn/ =
Vn =

288
460
-

266
426
-

5668 5650
5460 5449
5438 5427
5450 5439
6.61 kip/ft
9.91 kip/ft

www.ascsd.com

Composite and Non-Composite Deck Catalog May 2014

133

ACUSTADEK

LRFD - Diaphragm Shear, Sn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4
6x6 W2.9xW2.9
6x6 W4.0xW4.0
4x4 W4xW4
4x4 W6xW6
3/4" Welded Shear Studs
As = 0.028 in2/ft
As = 0.058 in2/ft
As = 0.080 in2/ft
As = 0.120 in2/ft
As = 0.180 in2/ft
8 in o.c.
n/a
7750
8740
10540
13240
16 in o.c.
n/a
7750
8740
9890
9890
24 in o.c.
n/a
6590
6590
6590
6590

D PANEL

10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6"


ASD & LRFD - Superimposed Load, W (psf)
976 869 778 700 633 573 522 476 435 399
ASD, W/
1561 1391 1245 1120 1012 918 835 761 696 639
LRFD, W
L/360
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
5942 5942 5900 5861 5826 5794 5765 5772 5746 5722
PAF Base Steel .25"
5584 5603 5578 5555 5533 5514 5497 5515 5498 5483
PAF Base Steel 0.109"
5545 5566 5543 5521 5502 5484 5467 5487 5471 5457
#12 Screw Base Steel .034"
5557 5579 5555 5533 5514 5496 5480 5499 5484 5469
Concrete + Deck = 82.8 psf
Icr = 249.6 in4/ft
Mno/= 131.9
(Icr+Iu)/2 = 357.7 in4/ft
Iu = 465.8 in4/ft
Mno= 201.7

118
189
-

C PANELS

9'-6"

130
207
-

N PANELS

10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6"


ASD & LRFD - Superimposed Load, W (psf)
792
705 630 566 510 462 419 381 348 318
ASD, W/
1268 1128 1008 905 816 738 670 610 556 509
LRFD, W
L/360
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
5755 5750 5717 5688 5662 5637 5615 5616 5597 5578
PAF Base Steel .25"
5478 5487 5467 5450 5434 5420 5407 5416 5404 5393
PAF Base Steel 0.109"
5457 5467 5449 5433 5418 5404 5391 5402 5390 5380
#12 Screw Base Steel .034"
5443 5454 5437 5421 5406 5393 5381 5392 5381 5370
Concrete + Deck = 82.1 psf
Icr = 213.1 in4/ft
Mno/= 108.5
4
(Icr+Iu)/2 = 330.1 in /ft
Iu = 447.0 in4/ft
Mno= 166.0
9'-0"

Triple
12' - 1"
13' - 7"

B PANELS

All Gages

Single
10' - 8"
11' - 4"

10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6"


ASD & LRFD - Superimposed Load, W (psf)
604
536 478 428 384 346 313 284 258 235
ASD, W/
967
858 764 684 615 554 501 454 412 375
LRFD, W
L/360
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
5584 5576 5552 5532 5513 5495 5479 5477 5463 5450
PAF Base Steel .25"
5381 5384 5370 5358 5347 5337 5328 5331 5323 5315
PAF Base Steel 0.109"
5366 5369 5356 5345 5334 5325 5316 5320 5312 5305
#12 Screw Base Steel .034"
5353 5357 5345 5334 5324 5315 5306 5311 5303 5296
Concrete + Deck = 81.4 psf
Icr = 173.1 in4/ft
Mno/= 84.5
(Icr+Iu)/2 = 300.3 in4/ft
Iu = 427.5 in4/ft
Mno= 129.3

Vertical Load Span (in)

16

Gage
18
16

2W PANELS

9'-0"

Vertical Load Span (in)

18

Triple
8' - 9"
10' - 1"

Vertical Load Span (in)

Vertical Load Span (in)

20

Maximum Unshored Span (in)

Double
8' - 6"
9' - 10"

3W PANELS

GA

Single
7' - 6"
8' - 8"

GENERAL INFORMATION

TABLE OF CONTENTS

5.3 NH-32 Composite Deck


5" Total Slab Depth
Light Weight Concrete (110 pcf)

Concrete Volume 0.979yd3/100ft2

Gage
22
20

GA

22

Single
10' - 7"
12' - 4"

9'-0"

9'-6"

ASD, W/
LRFD, W
L/360

207
332
-

184
294
-

1659
1493
1480
1468
31.5
76.03

1651
1493
1481
1470
psf
in4/ft

9'-0"

9'-6"

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"
Concrete + Deck =
(Icr+Iu)/2 =

Single
13' - 6"
14' - 2"

Double
16' - 2"
17' - 7"

163
261
-

146
234
-

131
209
-

118
188
-

106
170
-

96
154
-

87
139
-

1632
1482
1471
1460

1615
1473
1461
1451
Icr =
Iu =

1600
1464
1453
1443
51.6
100.4

1586
1456
1445
1436
in4/ft
in4/ft

1573
1448
1438
1430

1569
1450
1441
1432

1558
1443
1434
1426
Mno/=
Mno=

79
126
-

LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern

9'-0"

1548 1538
1437 1431
1428 1423
1420 1415
29.3 kip-in/ft
44.9 kip-in/ft

9'-6"

9'-6"

72
115
-

10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6"


ASD & LRFD - Superimposed Load, W (psf)
383 341 305 268 233 204 179 159 141 126
ASD, W/
612 546 488 439 397 360 327 298 273 250
LRFD, W
L/360
268 233 204 179 159 141 126
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
2108 2109 2066 2028 1993 1961 1931 1939 1913 1888
PAF Base Steel .25"
1751 1770 1744 1721 1700 1681 1663 1681 1665 1650
PAF Base Steel 0.109"
1712 1733 1709 1688 1668 1650 1634 1653 1638 1624
#12 Screw Base Steel .034"
1720 1741 1717 1696 1676 1658 1642 1661 1646 1632
Concrete + Deck = 33.3 psf
Icr = 81.3 in4/ft
Mno/= 51.8
(Icr+Iu)/2 = 100.3 in4/ft
Iu = 119.4 in4/ft
Mno= 79.3

65
104
-

59
95
-

1529
1426
1418
1411

1521
1421
1413
1406
Vn/ =
Vn =

54
87
-

49
79
-

1520 1512
1423 1419
1416 1411
1409 1405
2.34 kip/ft
4.67 kip/ft

14'-0" 14'-6" 15'-0" 15'-6" 16'-0"


87
140
-

80
128
-

73
117
-

1597
1467
1457
1448
kip-in/ft
kip-in/ft

1586
1460
1451
1442

1575
1454
1445
1437
Vn/ =
Vn =

67
107
-

61
98
-

1576 1566
1458 1452
1449 1444
1441 1436
2.34 kip/ft
4.67 kip/ft

14'-0" 14'-6" 15'-0" 15'-6" 16'-0"


103
186
103

93
170
93

84
157
84

1724
1545
1532
1523
kip-in/ft
kip-in/ft

1708
1536
1523
1514

1693
1527
1515
1506
Vn/ =
Vn =

76
144
76

69
133
69

1697 1684
1536 1528
1524 1516
1516 1508
2.34 kip/ft
4.67 kip/ft

14'-0" 14'-6" 15'-0" 15'-6" 16'-0"


113
230
113

102
211
102

92
195
92

1866
1636
1611
1619
kip-in/ft
kip-in/ft

1845
1623
1599
1607

1825
1611
1587
1595
Vn/ =
Vn =

83
180
83

76
166
76

1835 1817
1627 1615
1604 1593
1612 1602
2.34 kip/ft
4.67 kip/ft

All Gages

9'-0"

Triple
16' - 2"
17' - 0"

10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" 15'-6" 16'-0"

ASD & LRFD - Superimposed Load, W (psf)

10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6"


ASD & LRFD - Superimposed Load, W (psf)
315
280 251 225 203 184 163 144 128
115
ASD, W/
504
449 401 360 325 294 267 243 221 202
LRFD, W
L/360
163 144 128
115
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
1918 1912 1880 1851 1824 1800 1778 1779 1759 1741
PAF Base Steel .25"
1640 1649 1630 1613 1597 1582 1569 1579 1567 1556
PAF Base Steel 0.109"
1620 1630 1612 1595 1580 1567 1554 1564 1553 1542
#12 Screw Base Steel .034"
1606 1617 1599 1583 1569 1556 1544 1554 1543 1533
Concrete + Deck = 32.6 psf
Icr = 70.5 in4/ft
Mno/= 43.2
4
(Icr+Iu)/2 = 91.29 in /ft
Iu = 112.1 in4/ft
Mno= 66.0
Vertical Load Span (in)

16

Gage
18
16

10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6"


ASD & LRFD - Superimposed Load, W (psf)
245
218 194 174 156 141 128
116
105
96
ASD, W/
393
348
311
278 250 226 204 185 168 153
LRFD, W
L/360
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
1743 1734 1711 1690 1671 1654 1638 1636 1622 1609
PAF Base Steel .25"
1540 1542 1529 1517 1506 1495 1486 1490 1482 1474
PAF Base Steel 0.109"
1525 1528 1515 1503 1493 1483 1475 1479 1471 1464
#12 Screw Base Steel .034"
1512 1515 1503 1492 1482 1473 1465 1470 1462 1455
Concrete + Deck = 31.9 psf
Icr = 58.5 in4/ft
Mno/= 34.2
(Icr+Iu)/2 = 81.52 in4/ft
Iu = 104.5 in4/ft
Mno= 52.3
Vertical Load Span (in)

18

Triple
12' - 6"
14' - 2"

Vertical Load Span (in)

Vertical Load Span (in)

20

Maximum Unshored Span (in)

Double
11' - 9"
13' - 8"

LRFD - Diaphragm Shear, Sn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4
6x6 W2.9xW2.9
6x6 W4.0xW4.0
4x4 W4xW4
4x4 W6xW6
3/4" Welded Shear Studs
As = 0.028 in2/ft
As = 0.058 in2/ft
As = 0.080 in2/ft
As = 0.120 in2/ft
As = 0.180 in2/ft
8 in o.c.
2710
4060
5050
6850
9550
16 in o.c.
2710
4060
5050
6850
9550
24 in o.c.
2710
4060
5050
6590
6590

134

Composite and Non-Composite Deck Catalog May 2014

www.ascsd.com

TABLE OF CONTENTS

NH-32 Composite Deck 5.3


5 12" Total Slab Depth
Light Weight Concrete (110 pcf)

Concrete Volume 1.982yd3/100ft2


3 Hour Fire Rating


Gage
22
20

22

9'-6"

ASD, W/
LRFD, W
L/360

246
394
-

218
349
-

1983
1817
1804
1793
36.2
99.79

1975
1817
1805
1794
psf
in4/ft

9'-0"

9'-6"

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"
Concrete + Deck =
(Icr+Iu)/2 =

Double
15' - 6"
17' - 1"

10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" 15'-6" 16'-0"

ASD & LRFD - Superimposed Load, W (psf)


194
311
-

174
278
-

156
249
-

140
224
-

127
202
-

114
183
-

104
166
-

1956
1806
1795
1784

1939
1797
1786
1775
Icr =
Iu =

1924
1788
1777
1767
67.3
132.2

1910
1780
1769
1760
in4/ft
in4/ft

1897
1772
1762
1754

1893
1774
1765
1756

1882
1767
1758
1750
Mno/=
Mno=

94
151
-

LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern

9'-0"

9'-6"

71
114
-

1853
1750
1742
1735

1845
1745
1737
1730
Vn/ =
Vn =

65
104
-

59
95
-

1844 1836
1747 1743
1740 1735
1733 1729
2.68 kip/ft
5.31 kip/ft

14'-0" 14'-6" 15'-0" 15'-6" 16'-0"


104
167
-

95
153
-

87
140
-

1921
1791
1781
1773
kip-in/ft
kip-in/ft

1910
1784
1775
1766

1899
1778
1769
1761
Vn/ =
Vn =

80
128
-

73
118
-

1900 1890
1782 1776
1773 1768
1766 1760
2.68 kip/ft
5.37 kip/ft

14'-0" 14'-6" 15'-0" 15'-6" 16'-0"


134
221
134

121
203
121

109
187
109

2048
1869
1856
1847
kip-in/ft
kip-in/ft

2032
1860
1847
1839

2017
1851
1839
1830
Vn/ =
Vn =

99
172
99

90
159
90

2021 2008
1860 1852
1848 1840
1840 1832
2.68 kip/ft
5.37 kip/ft

14'-0" 14'-6" 15'-0" 15'-6" 16'-0"


133
252
133

120
233
120

2190
1960
1935
1943
kip-in/ft
kip-in/ft

2169
1947
1923
1931

2149
1935
1911
1919
Vn/ =
Vn =

109
215
109

99
199
99

2159 2141
1951 1939
1928 1918
1936 1926
2.68 kip/ft
5.37 kip/ft

www.ascsd.com

Composite and Non-Composite Deck Catalog May 2014

135

ACUSTADEK

LRFD - Diaphragm Shear, Sn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4
6x6 W2.9xW2.9
6x6 W4.0xW4.0
4x4 W4xW4
4x4 W6xW6
3/4" Welded Shear Studs
As = 0.028 in2/ft
As = 0.058 in2/ft
As = 0.080 in2/ft
As = 0.120 in2/ft
As = 0.180 in2/ft
8 in o.c.
3080
4430
5420
7220
9920
16 in o.c.
3080
4430
5420
7220
9890
24 in o.c.
3080
4430
5420
6590
6590

D PANEL

147
274
147

C PANELS

10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6"


ASD & LRFD - Superimposed Load, W (psf)
455 405 363 326 295 266 234 207 184 164
ASD, W/
727 648 581 522 472 428 389 355 325 298
LRFD, W
L/360
266 234 207 184 164
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
2432 2433 2390 2352 2317 2285 2255 2263 2237 2212
PAF Base Steel .25"
2075 2094 2068 2045 2024 2005 1987 2005 1989 1974
PAF Base Steel 0.109"
2036 2057 2033 2012 1992 1974 1958 1977 1962 1948
#12 Screw Base Steel .034"
2044 2065 2042 2020 2000 1983 1966 1985 1970 1956
Concrete + Deck = 38.0 psf
Icr = 105.8 in4/ft
Mno/= 61.4
(Icr+Iu)/2 = 130.9 in4/ft
Iu = 156.1 in4/ft
Mno= 93.9

78
125
-

N PANELS

9'-6"

86
137
-

1872 1862
1761 1755
1752 1747
1745 1739
34.7 kip-in/ft
53.1 kip-in/ft

10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6"


ASD & LRFD - Superimposed Load, W (psf)
375
333 298 268 242 219 198 181 165 150
ASD, W/
599
533 477 428 386 350 318 289 264 242
LRFD, W
L/360
150
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
2242 2236 2204 2175 2148 2124 2102 2103 2083 2065
PAF Base Steel .25"
1964 1973 1954 1937 1921 1907 1893 1903 1891 1880
PAF Base Steel 0.109"
1944 1954 1936 1919 1904 1891 1878 1888 1877 1866
#12 Screw Base Steel .034"
1930 1941 1923 1907 1893 1880 1868 1878 1867 1857
Concrete + Deck = 37.3 psf
Icr = 91.8 in4/ft
Mno/= 51.2
4
(Icr+Iu)/2 = 119.4 in /ft
Iu = 147.0 in4/ft
Mno= 78.3
9'-0"

Triple
15' - 8"
16' - 5"

B PANELS

All Gages

Single
13' - 1"
13' - 8"

10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6"


ASD & LRFD - Superimposed Load, W (psf)
291
259 231 207 186 168 152 138 125
114
ASD, W/
466
414 369 331 298 269 243 221 201 183
LRFD, W
L/360
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
2067 2058 2035 2014 1995 1978 1962 1960 1946 1933
PAF Base Steel .25"
1864 1866 1853 1841 1830 1819 1810 1814 1806 1798
PAF Base Steel 0.109"
1849 1852 1839 1827 1817 1807 1799 1803 1795 1788
#12 Screw Base Steel .034"
1836 1839 1827 1816 1806 1797 1789 1794 1786 1779
Concrete + Deck = 36.6 psf
Icr = 76.3 in4/ft
Mno/= 40.5
(Icr+Iu)/2 = 106.9 in4/ft
Iu = 137.4 in4/ft
Mno= 62.0

Vertical Load Span (in)

16

Gage
18
16

2W PANELS

9'-0"

Vertical Load Span (in)

18

Triple
11' - 11"
13' - 7"

Vertical Load Span (in)

Vertical Load Span (in)

20

Maximum Unshored Span (in)

Double
11' - 3"
13' - 1"

3W PANELS

GA

Single
10' - 2"
11' - 10"

GENERAL INFORMATION

TABLE OF CONTENTS

5.3 NH-32 Composite Deck


6" Total Slab Depth
Light Weight Concrete (110 pcf)

Concrete Volume 1.288yd3/100ft2

Gage
22
20

GA

22

Single
9' - 9"
11' - 4"

9'-0"

9'-6"

ASD, W/
LRFD, W
L/360

288
460
-

255
408
-

2307
2141
2128
2117
40.9
128.3

2299
2141
2129
2118
psf
in4/ft

9'-0"

9'-6"

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"
Concrete + Deck =
(Icr+Iu)/2 =

Single
12' - 9"
13' - 4"

Double
14' - 11"
16' - 7"

227
364
-

203
325
-

182
292
-

164
263
-

148
237
-

134
215
-

122
195
-

2280
2130
2119
2108

2263
2121
2110
2099
Icr =
Iu =

2248
2112
2101
2091
85.9
170.6

2234
2104
2094
2084
in4/ft
in4/ft

2221
2096
2087
2078

2218
2098
2089
2080

2206
2091
2082
2074
Mno/=
Mno=

111
177
-

LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern

9'-0"

2196 2186
2085 2079
2077 2071
2069 2063
40.4 kip-in/ft
61.9 kip-in/ft

9'-6"

9'-6"

101
161
-

10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6"


ASD & LRFD - Superimposed Load, W (psf)
533 475 426 383 346 314 286 261 236
211
ASD, W/
853 760 681 613 554 503 457 417 382 351
LRFD, W
L/360
236
211
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
2756 2757 2714 2676 2641 2609 2579 2587 2561 2536
PAF Base Steel .25"
2399 2418 2392 2369 2348 2329 2311 2329 2313 2298
PAF Base Steel 0.109"
2360 2381 2357 2336 2316 2298 2282 2301 2286 2272
#12 Screw Base Steel .034"
2368 2389 2366 2344 2324 2307 2290 2309 2294 2280
Concrete + Deck = 42.7 psf
Icr = 135.1 in4/ft
Mno/= 71.8
(Icr+Iu)/2 = 167.7 in4/ft
Iu = 200.3 in4/ft
Mno= 109.9

92
147
-

84
134
-

2177
2074
2066
2059

2169
2069
2061
2054
Vn/ =
Vn =

77
123
-

70
112
-

2168 2160
2071 2067
2064 2060
2057 2053
3.05 kip/ft
5.59 kip/ft

14'-0" 14'-6" 15'-0" 15'-6" 16'-0"


123
196
-

112
180
-

103
165
-

2245
2115
2105
2097
kip-in/ft
kip-in/ft

2234
2108
2099
2091

2223
2102
2093
2085
Vn/ =
Vn =

94
151
-

87
139
-

2224 2214
2106 2100
2097 2092
2090 2084
3.05 kip/ft
6.10 kip/ft

14'-0" 14'-6" 15'-0" 15'-6" 16'-0"


163
261
-

150
240
-

138
221
-

2372
2193
2180
2171
kip-in/ft
kip-in/ft

2356
2184
2171
2163

2341
2175
2163
2154
Vn/ =
Vn =

127
203
127

116
188
116

2345 2332
2184 2176
2172 2164
2164 2156
3.05 kip/ft
6.10 kip/ft

14'-0" 14'-6" 15'-0" 15'-6" 16'-0"


189
322
189

170
297
170

154
274
154

2514
2284
2259
2267
kip-in/ft
kip-in/ft

2493
2271
2247
2255

2473
2259
2235
2243
Vn/ =
Vn =

139
254
139

126
235
126

2483 2465
2275 2263
2252 2242
2260 2250
3.05 kip/ft
6.10 kip/ft

All Gages

9'-0"

Triple
15' - 3"
16' - 0"

10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" 15'-6" 16'-0"

ASD & LRFD - Superimposed Load, W (psf)

10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6"


ASD & LRFD - Superimposed Load, W (psf)
439
391 350 314 283 257 233 212 194 178
ASD, W/
702
625 559 503 453
411
373 340 310 284
LRFD, W
L/360
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
2566 2560 2528 2499 2472 2448 2426 2427 2407 2389
PAF Base Steel .25"
2288 2297 2278 2261 2245 2231 2217 2227 2215 2204
PAF Base Steel 0.109"
2268 2278 2260 2243 2228 2215 2202 2213 2201 2190
#12 Screw Base Steel .034"
2254 2265 2247 2231 2217 2204 2192 2202 2191 2181
Concrete + Deck = 42.0 psf
Icr = 117.3 in4/ft
Mno/= 59.8
4
(Icr+Iu)/2 = 153.2 in /ft
Iu = 189.0 in4/ft
Mno= 91.4
Vertical Load Span (in)

16

Gage
18
16

10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6"


ASD & LRFD - Superimposed Load, W (psf)
341
303 270 242 218 197 178 162 147 134
ASD, W/
546
485 432 388 349 315 285 259 236 215
LRFD, W
L/360
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
2391 2382 2359 2338 2319 2302 2286 2284 2270 2257
PAF Base Steel .25"
2188 2190 2177 2165 2154 2144 2134 2138 2130 2122
PAF Base Steel 0.109"
2173 2176 2163 2152 2141 2131 2123 2127 2119 2112
#12 Screw Base Steel .034"
2160 2163 2151 2140 2130 2121 2113 2118 2110 2103
Concrete + Deck = 41.2 psf
Icr = 97.5 in4/ft
Mno/= 47.3
(Icr+Iu)/2 = 137.2 in4/ft
Iu = 177.0 in4/ft
Mno= 72.3
Vertical Load Span (in)

18

Triple
11' - 5"
13' - 1"

Vertical Load Span (in)

Vertical Load Span (in)

20

Maximum Unshored Span (in)

Double
10' - 10"
12' - 8"

LRFD - Diaphragm Shear, Sn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4
6x6 W2.9xW2.9
6x6 W4.0xW4.0
4x4 W4xW4
4x4 W6xW6
3/4" Welded Shear Studs
As = 0.028 in2/ft
As = 0.058 in2/ft
As = 0.080 in2/ft
As = 0.120 in2/ft
As = 0.180 in2/ft
8 in o.c.
3450
4800
5790
7590
10290
16 in o.c.
3450
4800
5790
7590
9890
24 in o.c.
3450
4800
5790
6590
6590

136

Composite and Non-Composite Deck Catalog May 2014

www.ascsd.com

TABLE OF CONTENTS

NH-32 Composite Deck 5.3


6 14" Total Slab Depth
Light Weight Concrete (110 pcf)

Concrete Volume 1.369yd3/100ft2


2 Hour Fire Rating


Gage
22
20

22

9'-6"

ASD, W/
LRFD, W
L/360

309
495
-

274
439
-

2470
2303
2290
2279
43.2
144.4

2461
2303
2291
2280
psf
in4/ft

9'-0"

9'-6"

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"
Concrete + Deck =
(Icr+Iu)/2 =

Double
14' - 8"
16' - 5"

10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" 15'-6" 16'-0"

ASD & LRFD - Superimposed Load, W (psf)


244
391
-

219
350
-

196
314
-

177
283
-

160
256
-

145
232
-

131
210
-

2442
2292
2281
2270

2425
2283
2272
2261
Icr =
Iu =

2410
2274
2263
2254
96.3
192.4

2396
2266
2256
2246
in4/ft
in4/ft

2383
2258
2249
2240

2380
2260
2251
2242

2368
2253
2244
2236
Mno/=
Mno=

120
191
-

LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern

9'-0"

9'-6"

91
145
-

2339
2236
2228
2221

2331
2231
2223
2216
Vn/ =
Vn =

83
133
-

76
121
-

2330 2322
2233 2229
2226 2222
2219 2215
3.24 kip/ft
5.73 kip/ft

14'-0" 14'-6" 15'-0" 15'-6" 16'-0"


132
212
-

121
194
-

111
178
-

2407
2277
2267
2259
kip-in/ft
kip-in/ft

2396
2270
2261
2253

2385
2264
2255
2247
Vn/ =
Vn =

102
163
-

94
150
-

2386 2376
2268 2262
2259 2254
2252 2246
3.24 kip/ft
6.48 kip/ft

14'-0" 14'-6" 15'-0" 15'-6" 16'-0"


176
281
-

162
259
-

149
238
-

2534
2356
2343
2333
kip-in/ft
kip-in/ft

2518
2346
2333
2325

2503
2337
2325
2316
Vn/ =
Vn =

137
220
-

127
203
-

2507 2494
2346 2338
2334 2326
2326 2318
3.24 kip/ft
6.48 kip/ft

14'-0" 14'-6" 15'-0" 15'-6" 16'-0"


191
321
191

173
296
173

2676
2446
2421
2429
kip-in/ft
kip-in/ft

2655
2433
2409
2417

2635
2421
2397
2405
Vn/ =
Vn =

156
274
156

142
254
142

2645 2627
2437 2425
2414 2404
2422 2412
3.24 kip/ft
6.48 kip/ft

www.ascsd.com

Composite and Non-Composite Deck Catalog May 2014

137

ACUSTADEK

LRFD - Diaphragm Shear, Sn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4
6x6 W2.9xW2.9
6x6 W4.0xW4.0
4x4 W4xW4
4x4 W6xW6
3/4" Welded Shear Studs
As = 0.028 in2/ft
As = 0.058 in2/ft
As = 0.080 in2/ft
As = 0.120 in2/ft
As = 0.180 in2/ft
8 in o.c.
n/a
4990
5980
7780
10480
16 in o.c.
n/a
4990
5980
7780
9890
24 in o.c.
n/a
4990
5980
6590
6590

D PANEL

212
348
212

C PANELS

10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6"


ASD & LRFD - Superimposed Load, W (psf)
574 512 459 413 373 339 308 281 258 236
ASD, W/
919 819 734 661 597 542 493 450 412 378
LRFD, W
L/360
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
2918 2919 2876 2838 2803 2771 2741 2749 2723 2698
PAF Base Steel .25"
2561 2580 2554 2531 2510 2491 2473 2491 2475 2460
PAF Base Steel 0.109"
2522 2543 2519 2498 2478 2460 2444 2463 2448 2434
#12 Screw Base Steel .034"
2530 2551 2528 2506 2486 2469 2452 2471 2456 2442
Concrete + Deck = 45.0 psf
Icr = 151.7 in4/ft
Mno/= 77.3
(Icr+Iu)/2 = 188.6 in4/ft
Iu = 225.5 in4/ft
Mno= 118.2

99
159
-

N PANELS

9'-6"

109
174
-

2358 2348
2247 2241
2239 2233
2231 2225
43.4 kip-in/ft
66.4 kip-in/ft

10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6"


ASD & LRFD - Superimposed Load, W (psf)
473
421 377 338 305 277 251 229 209 192
ASD, W/
756
673 602 541 489 443 402 366 335 307
LRFD, W
L/360
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
2728 2722 2690 2661 2634 2610 2588 2589 2569 2551
PAF Base Steel .25"
2450 2459 2440 2423 2407 2393 2379 2389 2377 2366
PAF Base Steel 0.109"
2430 2440 2422 2405 2390 2377 2364 2375 2363 2352
#12 Screw Base Steel .034"
2416 2427 2409 2393 2379 2366 2354 2364 2353 2343
Concrete + Deck = 44.3 psf
Icr = 131.7 in4/ft
Mno/= 64.3
4
(Icr+Iu)/2 = 172.3 in /ft
Iu = 212.9 in4/ft
Mno= 98.3
9'-0"

Triple
15' - 0"
15' - 9"

B PANELS

All Gages

Single
12' - 7"
13' - 2"

10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6"


ASD & LRFD - Superimposed Load, W (psf)
367
326 291 261 235 212 192 174 159 145
ASD, W/
587
521 465 417 376 339 307 279 254 232
LRFD, W
L/360
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
2553 2544 2521 2500 2481 2464 2448 2446 2432 2419
PAF Base Steel .25"
2350 2352 2339 2327 2316 2306 2296 2300 2292 2284
PAF Base Steel 0.109"
2335 2338 2325 2314 2303 2294 2285 2289 2281 2274
#12 Screw Base Steel .034"
2322 2326 2313 2302 2292 2283 2275 2280 2272 2265
Concrete + Deck = 43.6 psf
Icr = 109.3 in4/ft
Mno/= 50.8
(Icr+Iu)/2 = 154.5 in4/ft
Iu = 199.6 in4/ft
Mno= 77.7

Vertical Load Span (in)

16

Gage
18
16

2W PANELS

9'-0"

Vertical Load Span (in)

18

Triple
11' - 2"
12' - 10"

Vertical Load Span (in)

Vertical Load Span (in)

20

Maximum Unshored Span (in)

Double
10' - 8"
12' - 5"

3W PANELS

GA

Single
9' - 6"
11' - 1"

GENERAL INFORMATION

TABLE OF CONTENTS

5.3 NH-32 Composite Deck

7 12" Total Slab Depth


Light Weight Concrete (110 pcf)

Concrete Volume 1.654yd3/100ft2


3 Hour Fire Rating

Gage
22
20

GA

22

Single
8' - 11"
10' - 4"

9'-0"

9'-6"

ASD, W/
LRFD, W
L/360

395
632
-

350
561
-

3077
2911
2898
2886
52.0
217.1

3068
2911
2899
2887
psf
in4/ft

9'-0"

9'-6"

Arc Spot Weld 1/2" Effective Dia


PAF Base Steel .25"
PAF Base Steel 0.109"
#12 Screw Base Steel .034"
Concrete + Deck =
(Icr+Iu)/2 =

Single
12' - 0"
12' - 7"

Double
13' - 9"
15' - 7"

312
500
-

280
448
-

251
402
-

227
363
-

205
328
-

186
297
-

169
270
-

3050
2900
2888
2878

3033
2890
2879
2869
Icr =
Iu =

3017
2881
2871
2861
142.0
292.2

3003
2873
2863
2854
in4/ft
in4/ft

2990
2866
2856
2847

2987
2868
2858
2850

2976
2861
2852
2844
Mno/=
Mno=

154
246
-

LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern

9'-0"

2965 2956
2855 2849
2846 2841
2838 2833
55.1 kip-in/ft
84.3 kip-in/ft

9'-6"

9'-6"

140
224
-

10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6"


ASD & LRFD - Superimposed Load, W (psf)
738 658 590 532 481 436 398 363 333 306
ASD, W/
1181 1053 944 851 769 698 636 581 532 489
LRFD, W
L/360
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
3526 3526 3484 3445 3410 3378 3349 3356 3330 3306
PAF Base Steel .25"
3168 3188 3162 3139 3118 3098 3081 3099 3083 3068
PAF Base Steel 0.109"
3130 3151 3127 3105 3086 3068 3052 3071 3056 3042
#12 Screw Base Steel .034"
3138 3159 3135 3114 3094 3076 3060 3079 3064 3050
Concrete + Deck = 53.8 psf
Icr = 225.3 in4/ft
Mno/= 98.9
(Icr+Iu)/2 = 282.6 in4/ft
Iu = 339.9 in4/ft
Mno= 151.3

128
205
-

117
187
-

2947
2844
2836
2828

2938
2839
2831
2824
Vn/ =
Vn =

107
172
-

98
157
-

2937 2930
2841 2836
2833 2829
2827 2822
4.00 kip/ft
6.30 kip/ft

14'-0" 14'-6" 15'-0" 15'-6" 16'-0"


171
273
-

156
250
-

144
230
-

3015
2884
2875
2866
kip-in/ft
kip-in/ft

3004
2878
2868
2860

2993
2872
2862
2855
Vn/ =
Vn =

132
211
-

122
194
-

2993 2984
2876 2870
2867 2861
2859 2854
4.00 kip/ft
8.01 kip/ft

14'-0" 14'-6" 15'-0" 15'-6" 16'-0"


227
363
-

209
334
-

193
308
-

3142
2963
2950
2941
kip-in/ft
kip-in/ft

3126
2953
2941
2932

3111
2944
2932
2924
Vn/ =
Vn =

178
285
-

165
263
-

3115 3101
2954 2945
2942 2934
2934 2926
4.00 kip/ft
8.01 kip/ft

14'-0" 14'-6" 15'-0" 15'-6" 16'-0"


281
450
-

260
415
-

240
384
-

3283
3054
3029
3037
kip-in/ft
kip-in/ft

3262
3041
3016
3024

3243
3028
3005
3013
Vn/ =
Vn =

222
355
-

206
330
-

3252 3234
3045 3033
3022 3011
3030 3019
4.00 kip/ft
8.01 kip/ft

All Gages

9'-0"

Triple
14' - 3"
15' - 2"

10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0" 15'-6" 16'-0"

ASD & LRFD - Superimposed Load, W (psf)

10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6"


ASD & LRFD - Superimposed Load, W (psf)
606
540 483 435 393 356 324 295 270 247
ASD, W/
970
864 773 696 628 569 518 472 432 396
LRFD, W
L/360
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
3336 3330 3298 3268 3242 3218 3195 3197 3177 3159
PAF Base Steel .25"
3058 3067 3048 3030 3015 3000 2987 2997 2985 2973
PAF Base Steel 0.109"
3038 3048 3030 3013 2998 2984 2972 2982 2971 2960
#12 Screw Base Steel .034"
3024 3034 3017 3001 2987 2973 2961 2972 2961 2951
Concrete + Deck = 53.1 psf
Icr = 195.2 in4/ft
Mno/= 82.1
4
(Icr+Iu)/2 = 258.5 in /ft
Iu = 321.7 in4/ft
Mno= 125.6
Vertical Load Span (in)

16

Gage
18
16

10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6"


ASD & LRFD - Superimposed Load, W (psf)
469
417 372 334 301 272 247 224 204 187
ASD, W/
750
667 596 534 481 435 394 359 327 299
LRFD, W
L/360
LRFD - Diaphragm Shear, Sn (plf / ft) 36/4 Attachment Pattern
Arc Spot Weld 1/2" Effective Dia
3160 3152 3129 3108 3089 3072 3056 3054 3040 3027
PAF Base Steel .25"
2958 2960 2947 2934 2923 2913 2904 2908 2899 2892
PAF Base Steel 0.109"
2942 2945 2933 2921 2911 2901 2892 2897 2889 2881
#12 Screw Base Steel .034"
2929 2933 2921 2910 2900 2891 2883 2887 2880 2873
Concrete + Deck = 52.4 psf
Icr = 161.4 in4/ft
Mno/= 64.6
(Icr+Iu)/2 = 232 in4/ft
Iu = 302.6 in4/ft
Mno= 98.8
Vertical Load Span (in)

18

Triple
10' - 6"
12' - 0"

Vertical Load Span (in)

Vertical Load Span (in)

20

Maximum Unshored Span (in)

Double
10' - 0"
11' - 8"

LRFD - Diaphragm Shear, Sn (plf / ft) for all vertical load spans, WWF Designation or Area of Steel per foot width
6x6 W1.4xW1.4
6x6 W2.9xW2.9
6x6 W4.0xW4.0
4x4 W4xW4
4x4 W6xW6
3/4" Welded Shear Studs
As = 0.028 in2/ft
As = 0.058 in2/ft
As = 0.080 in2/ft
As = 0.120 in2/ft
As = 0.180 in2/ft
8 in o.c.
n/a
5680
6670
8470
11170
16 in o.c.
n/a
5680
6670
8470
9890
24 in o.c.
n/a
5680
6590
6590
6590

138

Composite and Non-Composite Deck Catalog May 2014

www.ascsd.com

TABLE OF CONTENTS
GENERAL INFORMATION
3W PANELS
2W PANELS
B PANELS
N PANELS
C PANELS
D PANEL
ACUSTADEK

www.ascsd.com

Composite and Non-Composite Deck Catalog May 2014

139

TABLE OF CONTENTS

6.1 C0.9-32

7/8

2-11/16
32

Panel Properties

Gage
26
24
22
20

Weight
w
psf
1.1
1.4
1.7
2.0

Compression
Gage
26
24
22
20

Area
Ae
in2/ft
0.285
0.390
0.482
0.574

Base Metal
Thickness Yield Strength
t
Fy
in
ksi
0.0195
80
0.0254
80
0.0314
80
0.0374
80

Tensile
Strength
Fu
ksi
82
82
82
82

Area
Ag
in2/ft
0.299
0.390
0.482
0.574

Effective Section Modulus at Fy


Bending
Section
Modulus
Se+
in3/ft
0.061
0.080
0.098
0.116

Distance to
N.A. from
Bottom
yb
in
0.45
0.45
0.46
0.45

Section
Modulus
Sein3/ft
0.060
0.080
0.098
0.116

26

End
Interior

1"
377
473

Allowable (Rn/)
1.5"
2"
431
460
532
562

24

End
Interior

699
950

795
1060

22

End
Interior

1117
1585

20

End
Interior

1627
2370

Condition

Web Crippling Constraints

140

Radius of
Gyration
r
in
0.306
0.306
0.305
0.305

Effective Moment of Inertia for Deflection


Distance to
N.A. from
Bottom
yb
in
0.46
0.45
0.46
0.45

Reactions at Supports (plf) Based on Web Crippling


Gage

Gross Section Properties


Distance to
Moment of
N.A. from
Section
Inertia
Bottom
Modulus
Ig
yb
Sg
in4/ft
in
in3/ft
0.028
0.44
0.062
0.036
0.44
0.080
0.045
0.46
0.098
0.053
0.46
0.116

Moment of
Inertia
Ie+
in4/ft
0.028
0.036
0.045
0.053

Bearing Length of Webs

Moment of
Inertia
I ein4/ft
0.028
0.036
0.045
0.053

Uniform Load Only


Id = (2Ie+Ig)/3
I+
in4/ft
0.028
0.036
0.045
0.053

Iin4/ft
0.028
0.036
0.045
0.053

3"
460
562

1"
577
724

Factored (Rn)
1.5"
2"
660
703
814
860

3"
703
860

844
1117

844
1117

1069
1453

1216
1622

1292
1710

1292
1710

1264
1760

1341
1850

1341
1850

1710
2425

1935
2692

2052
2831

2052
2831

1833
2619

1940
2749

1940
2749

2489
3626

2804
4007

2968
4206

2968
4206

h=0.6"

r=0.63"

Composite and Non-Composite Deck Catalog May 2014

=48.8

www.ascsd.com

TABLE OF CONTENTS

C0.9-32 6.2

Inward Allowable (fb/) and Factored (fb) Distributed Load (lbs/ft2)


Gage

Span

Limit
Condition

SS

fb

L/360
L/240
fb /

26

DS

fb

L/360
fb /

TS

fb

L/360
L/240
fb /

SS

L/360
L/240
fb /

24

DS

fb

L/360
L/240
fb /
fb

L/360
L/240
fb /

SS

fb

L/360
L/240
fb /

DS

fb

L/360
L/240
fb /

TS

fb

L/360
L/240
fb /
fb

L/360
L/240
fb /

20

DS

fb

L/360
L/240

TS

fb

L/360
L/240

www.ascsd.com

Composite and Non-Composite Deck Catalog May 2014

141

ACUSTADEK

fb /

6' - 0"
41
65
6
9
40
63
14
21
50
79
13
19
53
84
7
11
53
84
18
27
67
106
16
24
65
104
9
14
65
104
22
33
82
129
20
30
77
122
11
16
77
122
26
38
96
153
23
35

D PANEL

SS

5' - 6"
49
77
7
11
47
75
18
27
59
94
16
24
63
101
10
14
63
101
23
35
79
126
21
32
78
123
12
18
78
123
28
43
97
154
26
39
92
146
14
21
92
146
33
50
115
182
30
46

C PANELS

22

5' - 0"
59
93
10
15
57
91
24
36
71
113
22
33
77
122
13
19
77
122
31
46
96
152
28
42
94
149
16
24
94
149
38
57
118
186
35
52
111
176
18
28
111
176
44
66
139
220
41
61

N PANELS

TS

Panel Span (Support Spacing)


3' - 6"
4' - 0"
4' - 6"
120
92
73
190
146
115
29
19
13
43
29
20
116
89
70
185
141
112
69
46
32
104
69
49
146
111
88
231
177
140
63
42
30
95
64
45
156
120
95
248
190
150
37
25
17
56
37
26
156
120
95
248
190
150
89
60
42
134
90
63
196
150
118
310
238
188
82
55
39
123
82
58
192
147
116
304
233
184
46
31
22
69
46
32
192
147
116
304
233
184
110
74
52
166
111
78
240
184
145
381
291
230
101
68
48
152
102
71
227
174
137
360
275
218
54
36
25
80
54
38
227
174
137
360
275
218
129
86
61
193
130
91
283
217
171
450
344
272
118
79
56
177
119
83

B PANELS

fb

3' - 0"
163
259
46
68
158
251
110
198
314
100
151
213
338
59
88
213
338
142
213
266
422
130
195
261
414
73
109
261
414
175
326
518
161
241
309
490
85
127
309
490
205
307
386
612
188
281

2W PANELS

L/240

2' - 6"
235
373
79
118
228
362
189
285
453
174
260
307
487
102
153
307
487
245
383
608
225
337
376
597
126
189
376
597
303
470
746
278
417
445
705
147
220
445
705
354
556
882
324
486

3W PANELS

fb /

2' - 0"
367
582
154
230
357
566
446
707
339
479
760
199
298
479
760
479
599
950
439
588
932
246
369
588
932
735
1165
543
695
1102
287
430
695
1102
691
868
1377
633
-

GENERAL INFORMATION

TABLE OF CONTENTS

6.3 C0.9-32

Normal Weight Concrete (145 pcf)


Maximum Unshored Spans

C0.9-32 Shoring Table


Total Slab Depth
(in)

Volume
cy/100sf

2.5

0.637

3.5

4.5

5.5

6.5

142

Gage
26
24
22
20

145 pcf Normal Weight Concrete


Maximum Unshored Span
Slab and Deck
psf
Single
Double
26.0
3' - 9"
4' - 4"
26.3
4' - 7"
5' - 5"
26.6
5' - 1"
6' - 3"
26.9
5' - 4"
7' - 0"

Triple
4' - 6"
5' - 6"
6' - 4"
6' - 7"

0.791

26
24
22
20

32.0
32.3
32.7
33.0

3' - 7"
4' - 4"
4' - 10"
5' - 0"

4' - 2"
5' - 2"
5' - 11"
6' - 8"

4' - 3"
5' - 2"
5' - 11"
6' - 3"

0.945

26
24
22
20

38.1
38.4
38.7
39.0

3' - 5"
4' - 2"
4' - 7"
4' - 9"

4' - 0"
4' - 11"
5' - 8"
6' - 4"

4' - 1"
5' - 0"
5' - 8"
5' - 11"

1.100

26
24
22
20

44.1
44.4
44.7
45.1

3' - 4"
4' - 0"
4' - 4"
4' - 7"

3' - 10"
4' - 8"
5' - 5"
6' - 0"

3' - 11"
4' - 9"
5' - 5"
5' - 8"

1.254

26
24
22
20

50.2
50.5
50.8
51.1

3' - 2"
3' - 10"
4' - 2"
4' - 5"

3' - 8"
4' - 6"
5' - 2"
5' - 9"

3' - 10"
4' - 7"
5' - 2"
5' - 5"

1.408

26
24
22
20

56.2
56.5
56.8
57.1

3' - 1"
3' - 9"
4' - 0"
4' - 3"

3' - 7"
4' - 4"
5' - 0"
5' - 7"

3' - 8"
4' - 5"
5' - 0"
5' - 3"

1.563

26
24
22
20

62.2
62.6
62.9
63.2

3' - 0"
3' - 7"
3' - 11"
4' - 1"

3' - 6"
4' - 3"
4' - 10"
5' - 5"

3' - 7"
4' - 3"
4' - 10"
5' - 1"

1.717

26
24
22
20

68.3
68.6
68.9
69.2

2' - 11"
3' - 6"
3' - 10"
4' - 0"

3' - 4"
4' - 1"
4' - 8"
5' - 3"

3' - 6"
4' - 2"
4' - 8"
4' - 11"

1.871

26
24
22
20

74.3
74.6
74.9
75.3

2' - 10"
3' - 5"
3' - 8"
3' - 11"

3' - 3"
4' - 0"
4' - 7"
5' - 1"

3' - 5"
4' - 1"
4' - 7"
4' - 10"

Composite and Non-Composite Deck Catalog May 2014

www.ascsd.com

TABLE OF CONTENTS

C0.9-32 6.3

Light Weight Concrete (110 pcf)


Maximum Unshored Spans

3W PANELS

C0.9-32 Shoring Table


Volume
cy/100sf

2.5

0.637

5.5

6.5

4' - 5"
5' - 6"
6' - 5"
7' - 2"

4' - 7"
5' - 7"
6' - 6"
6' - 10"

0.945

26
24
22
20

29.1
29.5
29.8
30.1

3' - 8"
4' - 6"
5' - 0"
5' - 3"

4' - 3"
5' - 4"
6' - 1"
6' - 10"

4' - 5"
5' - 4"
6' - 2"
6' - 6"

1.100

26
24
22
20

33.7
34.0
34.3
34.7

3' - 7"
4' - 4"
4' - 9"
5' - 0"

4' - 1"
5' - 1"
5' - 11"
6' - 7"

4' - 3"
5' - 2"
5' - 11"
6' - 2"

1.254

26
24
22
20

38.3
38.6
38.9
39.2

3' - 5"
4' - 2"
4' - 7"
4' - 10"

4' - 0"
4' - 11"
5' - 8"
6' - 4"

4' - 2"
5' - 0"
5' - 8"
5' - 11"

1.408

26
24
22
20

42.9
43.2
43.5
43.8

3' - 4"
4' - 1"
4' - 5"
4' - 8"

3' - 10"
4' - 9"
5' - 6"
6' - 1"

4' - 0"
4' - 10"
5' - 6"
5' - 9"

1.563

26
24
22
20

47.5
47.8
48.1
48.4

3' - 3"
3' - 11"
4' - 3"
4' - 6"

3' - 9"
4' - 8"
5' - 4"
5' - 11"

3' - 11"
4' - 8"
5' - 3"
5' - 7"

1.717

26
24
22
20

52.1
52.4
52.7
53.0

3' - 2"
3' - 10"
4' - 2"
4' - 4"

3' - 8"
4' - 6"
5' - 2"
5' - 9"

3' - 10"
4' - 7"
5' - 2"
5' - 5"

1.871

26
24
22
20

56.6
57.0
57.3
57.6

3' - 1"
3' - 8"
4' - 1"
4' - 3"

3' - 6"
4' - 4"
5' - 0"
5' - 7"

3' - 8"
4' - 5"
5' - 1"
5' - 8"

Composite and Non-Composite Deck Catalog May 2014

ACUSTADEK

www.ascsd.com

3' - 10"
4' - 8"
5' - 3"
5' - 6"

D PANEL

24.6
24.9
25.2
25.5

C PANELS

0.791

26
24
22
20

N PANELS

4.5

Triple
4' - 9"
5' - 10"
6' - 10"
7' - 3"

B PANELS

3.5

Gage
26
24
22
20

110 pcf Normal Weight Concrete


Maximum Unshored Span
Slab and Deck
psf
Single
Double
20.0
4' - 0"
4' - 7"
20.3
4' - 10"
5' - 10"
20.6
5' - 7"
6' - 9"
20.9
5' - 10"
7' - 7"

2W PANELS

Total Slab Depth


(in)

GENERAL INFORMATION

143

TABLE OF CONTENTS

6.4 C1.4-32

4-9/16

1-3/8

15/16
32
RD16

CP-32

Panel Properties

Gage
26
24
22
20
18

Weight
w
psf
1.1
1.4
1.7
2.0
2.6

Compression
Gage
26
24
22
20
18

Area
Ae
in2/ft
0.172
0.265
0.367
0.473
0.722

Base Metal
Thickness Yield Strength
t
Fy
in
ksi
0.0195
80
0.0254
80
0.0314
80
0.0374
80
0.0480
40

Tensile
Strength
Fu
ksi
82
82
82
82
55

Area
Ag
in2/ft
0.302
0.393
0.485
0.576
0.737

Effective Section Modulus at Fy


Bending
Section
Modulus
Se+
in3/ft
0.101
0.139
0.175
0.206
0.261

Distance to
N.A. from
Bottom
yb
in
0.65
0.67
0.68
0.68
0.68

Section
Modulus
Sein3/ft
0.106
0.141
0.174
0.206
0.261

26

End
Interior

1"
315
559

Allowable (Rn/)
2"
4"
399
517
686
865

24

End
Interior

533
936

668
1136

22

End
Interior

807
1410

20

End
Interior

18

End
Interior

Condition

Distance to
N.A. from
Bottom
yb
in
0.69
0.68
0.67
0.68
0.68

Moment of
Inertia
Ie+
in4/ft
0.078
0.103
0.128
0.150
0.191

Bearing Length of Webs

Moment of
Inertia
I ein4/ft
0.078
0.103
0.128
0.150
0.191

Uniform Load Only


Id = (2Ie+Ig)/3
I+
in4/ft
0.079
0.103
0.128
0.150
0.191

Iin4/ft
0.078
0.103
0.128
0.150
0.191

6"
522
873

1"
482
855

Factored (Rn)
2"
4"
610
791
1049
1324

6"
798
1335

858
1419

959
1568

815
1432

1021
1738

1313
2171

1467
2399

1003
1696

1280
2101

1439
2333

1235
2158

1535
2595

1958
3214

2201
3569

1134
1974

1399
2357

1773
2898

1988
3209

1735
3021

2140
3606

2713
4434

3042
4909

1223
2124

1493
2508

1875
3052

2094
3364

1871
3250

2284
3838

2868
4669

3204
5147

Web Crippling Constraints

144

Radius of
Gyration
r
in
0.512
0.511
0.511
0.510
0.509

Effective Moment of Inertia for Deflection

Reactions at Supports (plf) Based on Web Crippling


Gage

Gross Section Properties


Distance to
Moment of
N.A. from
Section
Inertia
Bottom
Modulus
Ig
yb
Sg
in4/ft
in
in3/ft
0.079
0.67
0.118
0.103
0.67
0.153
0.128
0.67
0.188
0.150
0.68
0.222
0.191
0.68
0.280

h=1.82"

r=0.125"

Composite and Non-Composite Deck Catalog May 2014

=45

www.ascsd.com

TABLE OF CONTENTS

C1.4-32 6.5

Gage

Span

SS
DS
TS
SS
DS
TS
SS
DS
TS

20

DS
TS

18

DS
TS

5' - 6"
80
126
21
31
84
134
50
75
105
167
46
68
110
175
27
40
111
177
65
98
139
221
60
89
138
219
33
50
138
219
81
121
172
274
74
111
163
259
39
59
163
259
95
142
204
324
87
130
138
219
50
75
138
219
121
172
274
111
166

Composite and Non-Composite Deck Catalog May 2014

6' - 0"
67
106
16
24
71
112
38
57
88
140
35
53
92
147
21
31
94
149
50
75
117
186
46
69
116
184
26
39
116
184
62
93
145
230
57
85
137
218
30
46
137
218
73
110
172
272
67
100
116
184
39
58
116
184
93
145
230
85
128

145

ACUSTADEK

www.ascsd.com

5' - 0"
96
153
27
41
102
162
66
99
127
202
61
91
133
211
36
54
135
214
87
130
169
268
79
119
167
265
45
67
167
265
107
161
209
331
98
148
198
314
52
79
198
314
126
189
247
392
116
174
167
265
67
100
167
265
161
209
331
148
-

D PANEL

SS

Panel Span (Support Spacing)


3' - 6"
4' - 0"
4' - 6"
197
151
119
312
239
189
80
54
38
120
81
57
208
159
126
330
253
200
193
129
91
260
199
157
412
316
249
177
118
83
178
125
272
208
164
431
330
261
105
70
49
157
105
74
275
211
167
437
334
264
252
169
119
344
263
208
546
418
330
231
155
109
232
163
341
261
206
542
415
328
130
87
61
195
131
92
341
261
206
540
414
327
313
210
147
426
326
258
676
517
409
287
192
135
288
202
403
309
244
640
490
387
153
102
72
229
154
108
403
309
244
640
490
387
368
247
173
504
386
305
800
612
484
337
226
159
339
238
341
261
206
541
414
327
195
131
92
292
196
138
341
261
206
541
414
327
426
326
258
676
517
409
288
202
-

C PANELS

SS

3' - 0"
268
425
127
191
283
449
354
561
281
370
587
166
249
375
595
468
743
367
465
737
206
310
464
736
580
920
455
549
871
243
364
549
871
686
1089
536
464
736
310
464
736
580
920
-

N PANELS

22

2' - 6"
386
612
220
330
408
647
509
808
485
533
845
287
431
540
856
675
1070
634
669
1061
357
535
668
1059
835
1324
787
791
1254
420
629
791
1254
988
1568
926
668
1059
535
668
1059
835
1324
-

B PANELS

24

fb /
fb
L/360
L/240
fb /
fb
L/360
L/240
fb /
fb
L/360
L/240
fb /
fb
L/360
L/240
fb /
fb
L/360
L/240
fb /
fb
L/360
L/240
fb /
fb
L/360
L/240
fb /
fb
L/360
L/240
fb /
fb
L/360
L/240
fb /
fb
L/360
L/240
fb /
fb
L/360
L/240
fb /
fb
L/360
L/240
fb /
fb
L/360
L/240
fb /
fb
L/360
L/240
fb /
fb
L/360
L/240

2' - 0"
603
957
430
637
1010
796
1263
832
1320
561
843
1338
1054
1672
1045
1658
697
1045
1043
1655
1304
2069
1235
1960
819
1229
1235
1960
1544
2450
1043
1655
1043
1655
1304
2069
-

2W PANELS

26

Limit
Condition

3W PANELS

Inward Allowable (fb/) and Factored (fb) Distributed Load (lbs/ft2)

GENERAL INFORMATION

TABLE OF CONTENTS

6.6 C1.4-32

Normal Weight Concrete (145 pcf)


Maximum Unshored Spans

C1.4-32 Shoring Table


Total Slab Depth
(in)

Volume
cy/100sf

0.714

3.5

4.5

5.5

6.5

146

Gage
26
24
22
20
18

145 pcf Normal Weight Concrete


Maximum Unshored Span
Slab and Deck
psf
Single
Double
29.0
5' - 3"
6' - 5"
29.3
6' - 6"
7' - 10"
29.6
7' - 0"
8' - 11"
29.9
7' - 4"
9' - 8"
30.5
7' - 8"
8' - 10"

Triple
6' - 3"
7' - 10"
8' - 8"
9' - 1"
9' - 1"

0.868

26
24
22
20
18

35.1
35.4
35.7
36.0
36.5

5' - 0"
6' - 2"
6' - 7"
6' - 11"
7' - 3"

6' - 1"
7' - 5"
8' - 5"
9' - 2"
8' - 4"

6' - 0"
7' - 5"
8' - 2"
8' - 7"
8' - 6"

1.022

26
24
22
20
18

41.1
41.4
41.7
42.0
42.6

4' - 10"
5' - 10"
6' - 4"
6' - 8"
6' - 10"

5' - 10"
7' - 0"
8' - 0"
8' - 9"
8' - 0"

5' - 8"
7' - 1"
7' - 9"
8' - 2"
8' - 1"

1.177

26
24
22
20
18

47.1
47.4
47.8
48.1
48.6

4' - 7"
5' - 8"
6' - 0"
6' - 4"
6' - 7"

5' - 7"
6' - 9"
7' - 8"
8' - 4"
7' - 8"

5' - 6"
6' - 9"
7' - 5"
7' - 10"
7' - 9"

1.331

26
24
22
20
18

53.2
53.5
53.8
54.1
54.7

4' - 5"
5' - 5"
5' - 10"
6' - 2"
6' - 4"

5' - 5"
6' - 5"
7' - 4"
8' - 0"
7' - 4"

5' - 3"
6' - 6"
7' - 2"
7' - 7"
7' - 5"

1.485

26
24
22
20
18

59.2
59.5
59.8
60.2
60.7

4' - 3"
5' - 3"
5' - 7"
5' - 11"
6' - 1"

5' - 2"
6' - 3"
7' - 1"
7' - 8"
7' - 1"

5' - 1"
6' - 3"
6' - 11"
7' - 4"
7' - 2"

1.640

26
24
22
20
18

65.3
65.6
65.9
66.2
66.8

4' - 2"
5' - 1"
5' - 5"
5' - 9"
5' - 11"

5' - 0"
6' - 0"
6' - 10"
7' - 5"
6' - 10"

4' - 11"
6' - 0"
6' - 9"
7' - 1"
6' - 11"

1.794

26
24
22
20
18

71.3
71.6
71.9
72.2
72.8

4' - 0"
4' - 11"
5' - 4"
5' - 7"
5' - 8"

4' - 11"
5' - 10"
6' - 8"
7' - 2"
6' - 7"

4' - 9"
5' - 10"
6' - 7"
6' - 11"
6' - 8"

Composite and Non-Composite Deck Catalog May 2014

www.ascsd.com

TABLE OF CONTENTS

C1.4-32 6.6

Light Weight Concrete (110 pcf)


Maximum Unshored Spans

Volume
cy/100sf

0.714

3.5

www.ascsd.com

6' - 8"
8' - 1"
9' - 2"
10' - 0"
9' - 1"

6' - 6"
8' - 1"
8' - 11"
9' - 5"
9' - 4"

1.022

26
24
22
20
18

31.4
31.7
32.1
32.4
32.9

5' - 2"
6' - 5"
6' - 11"
7' - 3"
7' - 6"

6' - 4"
7' - 9"
8' - 9"
9' - 6"
8' - 9"

6' - 3"
7' - 9"
8' - 6"
9' - 0"
8' - 11"

1.177

26
24
22
20
18

36.0
36.3
36.6
37.0
37.5

5' - 0"
6' - 2"
6' - 7"
7' - 0"
7' - 3"

6' - 1"
7' - 5"
8' - 5"
9' - 2"
8' - 4"

6' - 0"
7' - 5"
8' - 2"
8' - 7"
8' - 6"

1.331

26
24
22
20
18

40.6
40.9
41.2
41.5
42.1

4' - 10"
5' - 11"
6' - 4"
6' - 8"
6' - 11"

5' - 11"
7' - 1"
8' - 1"
8' - 10"
8' - 1"

5' - 9"
7' - 2"
7' - 10"
8' - 3"
8' - 2"

1.485

26
24
22
20
18

45.2
45.5
45.8
46.1
46.7

4' - 8"
5' - 9"
6' - 2"
6' - 6"
6' - 8"

5' - 9"
6' - 10"
7' - 10"
8' - 6"
7' - 10"

5' - 7"
6' - 11"
7' - 7"
8' - 0"
7' - 11"

1.640

26
24
22
20
18

49.8
50.1
50.4
50.7
51.3

4' - 7"
5' - 7"
6' - 0"
6' - 4"
6' - 6"

5' - 6"
6' - 8"
7' - 7"
8' - 3"
7' - 7"

5' - 5"
6' - 8"
7' - 5"
7' - 9"
7' - 8"

1.794

26
24
22
20
18

54.4
54.7
55.0
55.3
55.8

4' - 5"
5' - 5"
5' - 10"
6' - 1"
6' - 4"

5' - 5"
6' - 5"
7' - 4"
8' - 0"
7' - 4"

5' - 3"
6' - 6"
7' - 2"
7' - 7"
7' - 5"

Composite and Non-Composite Deck Catalog May 2014

ACUSTADEK

6.5

5' - 5"
6' - 9"
7' - 3"
7' - 7"
7' - 11"

D PANEL

26.9
27.2
27.5
27.8
28.3

C PANELS

5.5

0.868

26
24
22
20
18

N PANELS

4.5

Triple
6' - 10"
8' - 7"
9' - 5"
9' - 11"
9' - 11"

B PANELS

Gage
26
24
22
20
18

110 pcf Normal Weight Concrete


Maximum Unshored Span
Slab and Deck
psf
Single
Double
22.3
5' - 8"
7' - 0"
22.6
7' - 2"
8' - 6"
22.9
7' - 8"
9' - 8"
23.2
8' - 1"
10' - 6"
23.8
8' - 4"
9' - 7"

2W PANELS

Total Slab Depth


(in)

3W PANELS

C1.4-32 Shoring Table

GENERAL INFORMATION

147

TABLE OF CONTENTS

7.1 4.5D-12

4-1/2

12
2 Welds

Panel Properties

Gage
20
18
16
14

Weight
w
psf
2.88
3.84
4.80
6.09

Compression
Gage
20
18
16
14

Area
Ae
in2/ft
0.513
0.801
1.147
1.599

Base Metal
Thickness Yield Strength
t
Fy
in
ksi
0.0359
33
0.0478
33
0.0598
33
0.075
33

Tensile
Strength
Fu
ksi
45
45
45
45

Area
Ag
in2/ft
0.848
1.132
1.432
1.785

Effective Section Modulus at Fy


Bending
Section
Modulus
Se+
in3/ft
0.927
1.335
1.723
2.166

Distance to
N.A. from
Bottom
yb
in
2.20
2.37
2.51
2.63

Section
Modulus
Sein3/ft
1.045
1.398
1.755
2.166

20

End
Interior

1"
222
226

Allowable (Rn/)
2"
4"
294
396
264
318

18

End
Interior

444
444

584
513

16

End
Interior

736
737

14

End
Interior

1227
1241

Condition

Web Crippling Constraints

148

Radius of
Gyration
r
in
1.805
1.799
1.793
1.786

Effective Moment of Inertia for Deflection


Distance to
N.A. from
Bottom
yb
in
2.63
2.62
2.62
2.63

Reactions at Supports (plf) Based on Web Crippling


Gage

Gross Section Properties


Distance to
Moment of
N.A. from
Section
Inertia
Bottom
Modulus
Ig
yb
Sg
in4/ft
in
in3/ft
2.763
2.62
1.056
3.665
2.62
1.398
4.605
2.62
1.755
5.691
2.63
2.166

Moment of
Inertia
Ie+
in4/ft
2.134
3.159
4.330
5.691

Bearing Length of Webs

Moment of
Inertia
I ein4/ft
2.743
3.665
4.605
5.691

Uniform Load Only


Id = (2Ie+Ig)/3
I+
in4/ft
2.344
3.328
4.422
5.691

Iin4/ft
2.750
3.665
4.605
5.691

8"
520
384

1"
333
346

Factored (Rn)
2"
4"
441
594
404
487

8"
780
588

781
611

1060
749

666
680

876
786

1172
935

1590
1146

960
843

1278
994

1727
1206

1104
1127

1440
1290

1917
1520

2590
1846

1590
1407

2102
1641

2827
1972

1841
1899

2384
2153

3153
2511

4240
3017

h=4.2"

r=0.125"

Composite and Non-Composite Deck Catalog May 2014

=90

www.ascsd.com

TABLE OF CONTENTS

4.5D-12 7.2

Inward Allowable (fb/) and Factored (fb) Distributed Load (lbs/ft2)


Gage

Span

Limit
Condition

SS

fb

L/360
L/240
fb /

20

DS

fb

L/360
fb /

TS

fb

L/360
L/240
fb /

SS

L/360
L/240
fb /

18

DS

fb

L/360
L/240
fb /
fb

L/360
L/240
fb /

SS

fb

L/360
L/240
fb /

DS

fb

L/360
L/240
fb /

TS

fb

L/360
L/240
fb /
L/360
L/240
fb /

14

DS

fb

L/360
L/240

TS

fb

L/360
L/240

www.ascsd.com

54
86
25
37

158
250
112
161
255
-

116
184
70
106
118
187
-

89
141
47
71
90
143
-

70
111
33
50

198
314
144
198
314
-

146
231
91
136
146
231
-

111
177
61
91
111
177
-

88
140
43
64

22
36
7
10

20
31
5
8

29
46
9
13

25
40
7
11

36
58
11
17

32
50
9
14

Exceeds
Maximum
Product Length
44
70
18
27

36
58
14
20

31
48
11
16

26
41
8
12

Exceeds
Maximum
Product Length
57
90
24
36

47
74
18
27

39
63
14
21

34
53
11
16

Exceeds
Maximum
Product Length
71
113
31
47

59
94
23
35

50
79
18
27

42
67
14
21

Exceeds
Maximum
Product Length

Composite and Non-Composite Deck Catalog May 2014

ACUSTADEK

fb /

69
109
36
53
72
114
-

30' - 0"
14
22
4
6

D PANEL

SS

fb

90
142
53
79
94
149
-

28' - 0"
16
25
5
7

C PANELS

16

122
194
84
128
203
-

26' - 0"
18
29
6
9

N PANELS

TS

16' - 0"
48
76
25
38
54
85
-

B PANELS

fb

14' - 0"
62
99
37
56
70
111
-

2W PANELS

L/240

Panel Span (Support Spacing)


18' - 0" 20' - 0" 22' - 0" 24' - 0"
38
31
25
21
60
48
40
34
18
13
10
7
26
19
14
11

12' - 0"
85
134
59
96
152
-

3W PANELS

fb /

10' - 0"
122
194
102
138
218
172
273
176
279
145
184
292
230
365
227
360
193
231
367
289
459
285
453
249
285
453
357
566
-

GENERAL INFORMATION

149

TABLE OF CONTENTS

7.3 4.5D-12

Normal Weight Concrete (145 pcf)


Maximum Unshored Spans

4.5D-12 Shoring Table


Total Slab Depth
(in)

Volume
cy/100sf

0.810

6 1/2

0.965

1.119

7 1/2

1.273

1.427

8 1/2

1.582

1.736

9 1/2

1.890

10

2.045

Gage
20
18
16
14
20
18
16
14
20
18
16
14
20
18
16
14
20
18
16
14
20
18
16
14
20
18
16
14
20
18
16
14
20
18
16
14

145 pcf Normal Weight Concrete


Maximum Unshored Span
Slab and Deck
psf
Single
Double
34.6
14' - 6"
15' - 6"
35.6
17' - 1"
16' - 0"
36.5
18' - 3"
16' - 0"
37.8
19' - 3"
16' - 0"
40.6
13' - 8"
14' - 8"
41.6
16' - 6"
16' - 0"
42.6
17' - 7"
16' - 0"
43.8
18' - 7"
16' - 0"
46.7
12' - 11"
14' - 1"
47.6
15' - 9"
16' - 0"
48.6
17' - 1"
16' - 0"
49.9
18' - 1"
16' - 0"
52.7
12' - 4"
13' - 6"
53.7
15' - 2"
15' - 6"
54.6
16' - 7"
16' - 0"
55.9
17' - 7"
16' - 0"
58.8
11' - 10"
13' - 0"
59.7
14' - 6"
14' - 11"
60.7
16' - 2"
16' - 0"
62.0
17' - 2"
16' - 0"
64.8
11' - 5"
12' - 6"
65.8
13' - 11"
14' - 5"
66.7
15' - 10"
16' - 0"
68.0
16' - 9"
16' - 0"
70.8
11' - 0"
12' - 1"
71.8
13' - 5"
13' - 11"
72.8
15' - 5"
15' - 6"
74.1
16' - 5"
16' - 0"
76.9
10' - 8"
11' - 9"
77.9
13' - 0"
13' - 6"
78.8
14' - 11"
15' - 1"
80.1
16' - 1"
16' - 0"
82.9
10' - 4"
11' - 5"
83.9
12' - 7"
13' - 2"
84.9
14' - 5"
14' - 8"
86.1
15' - 10"
16' - 0"

Triple
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"

Shaded area the span is governed by maximum deck panel length of 32 feet; 16 feet for double span, 10 feet 8 inches for triple span.

150

Composite and Non-Composite Deck Catalog May 2014

www.ascsd.com

TABLE OF CONTENTS

4.5D-12 7.3

Light Weight Concrete (110 pcf)


Maximum Unshored Spans

6 1/2

0.965

1.119

7 1/2

1.273

1.427

8 1/2

1.582

1.736

9 1/2

1.890

10

2.045

C PANELS

0.810

Triple
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"

N PANELS

Gage
20
18
16
14
20
18
16
14
20
18
16
14
20
18
16
14
20
18
16
14
20
18
16
14
20
18
16
14
20
18
16
14
20
18
16
14

110 pcf Normal Weight Concrete


Maximum Unshored Span
Slab and Deck
psf
Single
Double
26.9
15' - 7"
16' - 0"
27.9
18' - 2"
16' - 0"
28.9
19' - 5"
16' - 0"
30.1
20' - 5"
16' - 0"
31.5
15' - 1"
16' - 0"
32.5
17' - 7"
16' - 0"
33.4
18' - 9"
16' - 0"
34.7
19' - 9"
16' - 0"
36.1
14' - 5"
15' - 5"
37.1
17' - 0"
16' - 0"
38.0
18' - 2"
16' - 0"
39.3
19' - 2"
16' - 0"
40.7
13' - 9"
14' - 10"
41.7
16' - 7"
16' - 0"
42.6
17' - 8"
16' - 0"
43.9
18' - 8"
16' - 0"
45.3
13' - 2"
14' - 4"
46.2
16' - 1"
16' - 0"
47.2
17' - 3"
16' - 0"
48.5
18' - 3"
16' - 0"
49.9
12' - 9"
13' - 10"
50.8
15' - 6"
15' - 11"
51.8
16' - 10"
16' - 0"
53.1
17' - 10"
16' - 0"
54.4
12' - 3"
13' - 5"
55.4
15' - 1"
15' - 5"
56.4
16' - 6"
16' - 0"
57.6
17' - 6"
16' - 0"
59.0
11' - 11"
13' - 0"
60.0
14' - 7"
15' - 0"
60.9
16' - 3"
16' - 0"
62.2
17' - 2"
16' - 0"
63.6
11' - 7"
12' - 8"
64.6
14' - 2"
14' - 7"
65.5
15' - 11"
16' - 0"
66.8
16' - 11"
16' - 0"

B PANELS

Volume
cy/100sf

2W PANELS

Total Slab Depth


(in)

3W PANELS

4.5D-12 Shoring Table

GENERAL INFORMATION

D PANEL

Shaded area the span is governed by maximum deck panel length of 32 feet; 16 feet for double span, 10 feet 8 inches for triple span.

ACUSTADEK

www.ascsd.com

Composite and Non-Composite Deck Catalog May 2014

151

TABLE OF CONTENTS

7.4 4.5DF-24
4-1/2

24
RD31

4-1/2 Deep Deck Cellular

Panel Properties

Gage

Weight
w
psf
4.53
5.02
5.55
5.49
5.98
6.51
6.45
6.94
7.47

20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16

Compression
Gage

Area
Ae
in2/ft
0.957
1.101
1.249
1.244
1.401
1.548
1.499
1.659
1.820

20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16

Base Metal
Thickness Yield Strength
t
Fy
in
ksi
.0359/.036
33
.0359/.047
33
.0359/.059
33
.0478/.036
33
.0478/.047
33
.0478/.059
33
.0598/.036
33
.0598/.047
33
.0598/.059
33

Tensile
Strength
Fu
ksi
45
45
45
45
45
45
45
45
45

Area
Ag
in2/ft
1.193
1.353
1.514
1.439
1.599
1.760
1.685
1.845
2.005

Effective Section Modulus at Fy


Bending
Section
Modulus
Se+
in3/ft
1.008
1.026
1.038
1.526
1.555
1.576
2.110
2.152
2.184

Distance to
N.A. from
Bottom
yb
in
1.53
1.31
1.15
1.86
1.67
1.52
2.11
1.93
1.78

Section
Modulus
Sein3/ft
1.559
1.581
1.742
1.445
1.835
2.269
1.720
2.110
2.563

Condition

Distance to
N.A. from
Bottom
yb
in
3.05
2.72
2.42
3.12
2.87
2.62
3.14
2.94
2.74

Moment of
Inertia
Ie+
in4/ft
3.649
3.839
3.978
4.987
5.435
5.800
6.264
6.858
7.357

Bearing Length of Webs

Moment of
Inertia
I ein4/ft
3.629
4.299
4.920
4.509
5.266
6.001
5.400
6.213
7.030

Uniform Load Only


Id = (2Ie+Ig)/3
I+
in4/ft
4.008
4.290
4.506
5.252
5.747
6.152
6.427
7.052
7.579

Iin4/ft
3.995
4.597
5.135
4.933
5.634
6.286
5.851
6.622
7.361

8"
520
384

1"
333
346

Factored (Rn)
2"
4"
441
594
404
487

8"
780
588

20

End
Interior

1"
222
226

18

End
Interior

444
444

584
513

781
611

1060
749

666
680

876
786

1172
935

1590
1146

16

End
Interior

736
737

960
843

1278
994

1727
1206

1104
1127

1440
1290

1917
1520

2590
1846

14

End
Interior

1227
1241

1590
1407

2102
1641

2827
1972

1841
1899

2384
2153

3153
2511

4240
3017

Web Crippling Constraints

152

Allowable (Rn/)
2"
4"
294
396
264
318

Radius of
Gyration
r
in
1.991
1.959
1.917
2.004
1.996
1.974
2.002
2.008
2.000

Effective Moment of Inertia for Deflection

Reactions at Supports (plf) Based on Web Crippling


Beam
Gage

Gross Section Properties


Distance to
Moment of
N.A. from
Section
Inertia
Bottom
Modulus
Ig
yb
Sg
in4/ft
in
in3/ft
4.727
1.85
2.559
5.193
1.64
3.161
5.564
1.48
3.753
5.781
2.05
2.817
6.369
1.86
3.424
6.856
1.70
4.022
6.753
2.20
3.070
7.440
2.02
3.680
8.024
1.87
4.282

h=4.2"

r=0.125"

Composite and Non-Composite Deck Catalog May 2014

=90

www.ascsd.com

TABLE OF CONTENTS

4.5DF-24 7.5

Gage

Span

Limit
Condition
fb /

SS

fb

L/360
fb /

20/20

DS

fb

L/360
L/240
fb /
L/360
L/240
fb /

SS

fb

L/360
L/240
fb /

DS

L/360
L/240
fb /

TS

fb

L/360
L/240

SS

fb

L/360
L/240
fb /

20/16

DS

fb

L/360
fb /

TS

fb

L/360
L/240

28' - 0"

30' - 0"

133
211

92
146

68
108

52
82

41
65

33
53

27
44

23
37

20
31

17
27

15
23

64
-

43
-

30
-

22
33

16
25

13
19

10
15

8
12

6
10

205
326

143
226

105
166

80
127

63
101

51
81

135
214

94
149

69
109

53
84

42
66

34
54

28
44

23
37

20
32

17
27

15
24

68
-

46
-

32
-

23
-

18
26

14
20

11
16

9
13

7
10

208
330

145
229

106
169

81
129

64
102

52
83

137
217

95
151

70
111

53
85

42
67

34
54

28
45

24
38

20
32

17
28

15
24

48
-

34
-

25
-

18
28

14
21

11
17

9
13

7
11

229
364

159
253

117
186

90
142

71
112

57
91

Exceeds
Maximum
Product Length

208
329
-

Exceeds
Maximum
Product Length

211
335
-

214
339

Exceeds
Maximum
Product Length

D PANEL

L/240

26' - 0"

C PANELS

fb /

16' - 0"

N PANELS

20/18

fb

14' - 0"

B PANELS

TS

fb

12' - 0"

2W PANELS

L/240

Panel Span (Support Spacing)


18' - 0" 20' - 0" 22' - 0" 24' - 0"

10' - 0"

3W PANELS

Inward Allowable (fb/) and Factored (fb) Distributed Load (lbs/ft2)

GENERAL INFORMATION

ACUSTADEK

www.ascsd.com

Composite and Non-Composite Deck Catalog May 2014

153

TABLE OF CONTENTS

7.5 4.5DF-24

Normal Weight Concrete (145 pcf)


Maximum Unshored Spans

Inward Allowable (fb/) and Factored (fb) Distributed Load (lbs/ft2)


Gage

Span

Limit
Condition
fb /

SS

fb

L/360
L/240
fb /

18/20

DS

fb

L/360
L/240
fb /

TS

fb

L/360
L/240
fb /

SS

fb

L/360
L/240
fb /

18/18

DS

fb

L/360
L/240
fb /

TS

fb

L/360
L/240
fb /

SS

fb

L/360
L/240
fb /

18/16

DS

fb

L/360
L/240
fb /

TS

fb

L/360
L/240

154

Panel Span (Support Spacing)


18' - 0" 20' - 0" 22' - 0" 24' - 0"

10' - 0"

12' - 0"

14' - 0"

16' - 0"

26' - 0"

28' - 0"

30' - 0"

201
319

140
221

103
163

79
125

62
98

50
80

42
66

35
55

30
47

26
41

22
35

133
-

84
-

56
-

39
59

29
43

22
32

17
25

13
20

10
16

9
13

190
302

132
210

97
154

74
118

59
93

48
75

205
325

142
226

104
166

80
127

63
100

51
81

42
67

36
56

30
48

26
41

23
36

92
-

61
-

43
-

31
47

24
35

18
27

14
21

11
17

9
14

242
384

168
266

123
196

94
150

75
118

60
96

208
329

144
229

106
168

81
129

64
102

52
82

43
68

36
57

31
49

26
42

23
37

98
-

66
-

46
-

34
50

25
38

19
29

15
23

12
18

10
15

299
474

208
329

152
242

117
185

92
146

75
119

Exceeds
Maximum
Product Length

238
377
-

Exceeds
Maximum
Product Length

302
479
-

324
515

Exceeds
Maximum
Product Length

Composite and Non-Composite Deck Catalog May 2014

www.ascsd.com

TABLE OF CONTENTS

4.5DF-24 7.5

Light Weight Concrete (110 pcf)


Maximum Unshored Spans

Gage

Span

Limit
Condition
fb /

SS

fb

L/360

16/20

DS

fb

L/360
L/240
fb /

TS

L/360
L/240
fb /

SS

fb

L/360
L/240
fb /

DS

L/360
L/240
fb /

TS

fb

L/360
L/240

SS

fb

L/360
L/240
fb /

16/16

DS

fb

L/360
fb /

TS

fb

L/360
L/240

28' - 0"

30' - 0"

278
441

193
306

142
225

109
172

86
136

69
110

57
91

48
77

41
65

35
56

31
49

163
-

102
-

69
103

48
72

35
53

26
40

20
30

16
24

13
19

10
16

227
360

157
250

116
183

89
140

70
111

57
90

284
450

197
312

145
230

111
176

88
139

71
112

59
93

49
78

42
67

36
57

32
50

178
-

112
-

75
-

53
79

39
58

29
43

22
33

18
26

14
21

11
17

278
441

193
306

142
225

109
172

86
136

70
110

288
456

200
317

147
233

112
178

89
141

72
114

59
94

50
79

43
68

37
58

32
51

192
-

121
-

81
-

57
85

41
62

31
47

24
36

19
28

15
23

12
18

338
536

234
372

172
273

132
209

104
165

84
134

Exceeds
Maximum
Product Length

283
449
-

Exceeds
Maximum
Product Length

348
551
-

422
669

Exceeds
Maximum
Product Length

D PANEL

L/240

26' - 0"

C PANELS

fb /

16' - 0"

N PANELS

16/18

fb

14' - 0"

B PANELS

fb

12' - 0"

2W PANELS

L/240
fb /

Panel Span (Support Spacing)


18' - 0" 20' - 0" 22' - 0" 24' - 0"

10' - 0"

3W PANELS

Inward Allowable (fb/) and Factored (fb) Distributed Load (lbs/ft2)

GENERAL INFORMATION

ACUSTADEK

www.ascsd.com

Composite and Non-Composite Deck Catalog May 2014

155

TABLE OF CONTENTS

7.6 4.5DF-24

Normal Weight Concrete (145 pcf)


Maximum Unshored Spans

4.5DF-24 Shoring Table


Total Slab Depth
(in)

Volume
cy/100sf

0.821

1.130

1.438

1.747

10

2.056

Gage
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16

145 pcf Normal Weight Concrete


Maximum Unshored Span
Slab and Deck
psf
Single
Double
36.6
14' - 11"
17' - 1"
37.2
15' - 0"
17' - 1"
37.8
15' - 0"
17' - 1"
37.5
18' - 3"
17' - 9"
38.1
18' - 4"
19' - 11"
38.8
18' - 4"
20' - 0"
38.5
19' - 9"
19' - 2"
39.1
20' - 2"
20' - 0"
39.7
20' - 5"
20' - 0"
48.7
13' - 5"
15' - 6"
49.2
13' - 6"
15' - 7"
49.9
13' - 6"
15' - 8"
49.6
16' - 8"
16' - 2"
50.2
16' - 9"
18' - 2"
50.8
16' - 9"
19' - 2"
50.6
18' - 6"
17' - 7"
51.2
18' - 11"
19' - 4"
51.8
19' - 3"
20' - 0"
60.7
12' - 3"
14' - 4"
61.3
12' - 4"
14' - 5"
62.0
12' - 5"
14' - 6"
61.7
15' - 5"
15' - 0"
62.3
15' - 6"
16' - 10"
62.9
15' - 7"
17' - 9"
62.7
17' - 7"
16' - 3"
63.2
18' - 0"
17' - 11"
63.9
18' - 2"
19' - 9"
72.8
11' - 5"
13' - 5"
73.4
11' - 6"
13' - 6"
74.1
11' - 6"
13' - 7"
73.8
14' - 4"
14' - 0"
74.4
14' - 5"
15' - 9"
75.0
14' - 6"
16' - 7"
74.7
16' - 10"
15' - 3"
75.3
17' - 0"
16' - 10"
76.0
17' - 1"
18' - 6"
84.9
10' - 8"
12' - 8"
85.5
10' - 9"
12' - 9"
86.1
10' - 10"
12' - 9"
85.9
13' - 5"
13' - 3"
86.5
13' - 7"
14' - 10"
87.1
13' - 7"
15' - 8"
86.8
15' - 11"
14' - 4"
87.4
16' - 0"
15' - 10"
88.1
16' - 1"
17' - 5"

Triple
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"

Shaded area the span is governed by maximum deck panel length of 32 feet; 16 feet for double span, 10 feet 8 inches for triple span.

156

Composite and Non-Composite Deck Catalog May 2014

www.ascsd.com

TABLE OF CONTENTS

4.5DF-24 7.6

Light Weight Concrete (110 pcf)


Maximum Unshored Spans

1.130

1.438

1.747

10

2.056

D PANEL

C PANELS

0.821

Triple
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"

N PANELS

ACUSTADEK

Gage
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16

110 pcf Normal Weight Concrete


Maximum Unshored Span
Slab and Deck
psf
Single
Double
28.8
16' - 2"
18' - 5"
29.4
16' - 3"
18' - 6"
30.0
16' - 3"
18' - 6"
29.8
19' - 8"
19' - 2"
30.4
19' - 9"
20' - 0"
31.0
19' - 10"
20' - 0"
30.8
21' - 0"
20' - 0"
31.3
21' - 4"
20' - 0"
31.9
21' - 8"
20' - 0"
38.0
14' - 10"
17' - 0"
38.6
14' - 11"
17' - 1"
39.2
14' - 11"
17' - 1"
39.0
18' - 2"
17' - 8"
39.5
18' - 3"
19' - 10"
40.1
18' - 3"
20' - 0"
39.9
19' - 9"
19' - 2"
40.5
20' - 1"
20' - 0"
41.1
20' - 5"
20' - 0"
47.2
13' - 8"
15' - 10"
47.7
13' - 9"
15' - 11"
48.4
13' - 9"
15' - 11"
48.1
16' - 11"
16' - 6"
48.7
17' - 0"
18' - 6"
49.3
17' - 1"
19' - 6"
49.1
18' - 9"
17' - 10"
49.7
19' - 2"
19' - 8"
50.3
19' - 5"
20' - 0"
56.3
12' - 9"
14' - 10"
56.9
12' - 10"
14' - 11"
57.5
12' - 10"
15' - 0"
57.3
15' - 11"
15' - 6"
57.9
16' - 0"
17' - 5"
58.5
16' - 1"
18' - 4"
58.3
18' - 0"
16' - 10"
58.8
18' - 5"
18' - 7"
59.4
18' - 8"
20' - 0"
65.5
12' - 0"
14' - 1"
66.1
12' - 1"
14' - 2"
66.7
12' - 1"
14' - 2"
66.5
15' - 1"
14' - 8"
67.0
15' - 2"
16' - 6"
67.6
15' - 3"
17' - 4"
67.4
17' - 5"
15' - 11"
68.0
17' - 9"
17' - 7"
68.6
17' - 10"
19' - 4"

B PANELS

Volume
cy/100sf

2W PANELS

Total Slab Depth


(in)

3W PANELS

4.5DF-24 Shoring Table

Shaded area the span is governed by maximum deck panel length of 32 feet; 16 feet for double span, 10 feet 8 inches for triple span.

www.ascsd.com

GENERAL INFORMATION

Composite and Non-Composite Deck Catalog May 2014

157

TABLE OF CONTENTS

7.7 6D-12
9

12
2 Welds

Panel Properties

Gage
20
18
16
14

Weight
w
psf
3.25
4.33
5.41
6.86

Compression
Gage
20
18
16
14

Area
Ae
in2/ft
0.516
0.810
1.143
1.638

Base Metal
Thickness Yield Strength
t
Fy
in
ksi
0.0359
33
0.0478
33
0.0598
33
0.075
33

Tensile
Strength
Fu
ksi
45
45
45
45

Area
Ag
in2/ft
0.953
1.273
1.591
2.010

Effective Section Modulus at Fy


Bending
Section
Modulus
Se+
in3/ft
1.369
1.981
2.529
3.242

Distance to
N.A. from
Bottom
yb
in
2.93
3.12
3.28
3.44

Section
Modulus
Sein3/ft
1.453
2.085
2.590
3.244

20

End
Interior

1"
194
197

Allowable (Rn/)
2"
4"
256
414
230
314

18

End
Interior

400
400

525
462

16

End
Interior

674
675

14

End
Interior

1141
1154

Condition

Web Crippling Constraints

158

Radius of
Gyration
r
in
2.379
2.372
2.366
2.358

Effective Moment of Inertia for Deflection


Distance to
N.A. from
Bottom
yb
in
3.55
3.44
3.44
3.44

Reactions at Supports (plf) Based on Web Crippling


Gage

Gross Section Properties


Distance to
Moment of
N.A. from
Section
Inertia
Bottom
Modulus
Ig
yb
Sg
in4/ft
in
in3/ft
5.393
3.43
1.572
7.165
3.44
2.085
8.906
3.44
2.590
11.173
3.44
3.244

Moment of
Inertia
Ie+
in4/ft
4.211
6.180
8.304
11.144

Bearing Length of Webs

Moment of
Inertia
I ein4/ft
5.154
7.165
8.906
11.173

Uniform Load Only


Id = (2Ie+Ig)/3
I+
in4/ft
4.605
6.508
8.505
11.154

Iin4/ft
5.234
7.165
8.906
11.173

8"
453
335

1"
290
301

Factored (Rn)
2"
4"
385
620
352
480

8"
680
512

839
617

954
674

600
612

788
707

1259
944

1431
1031

880
772

1394
1016

1582
1105

1011
1033

1319
1182

2091
1554

2373
1691

1478
1308

2319
1692

2628
1833

1711
1766

2216
2001

3479
2589

3941
2805

h=5.7"

r=0.125"

Composite and Non-Composite Deck Catalog May 2014

=90

www.ascsd.com

TABLE OF CONTENTS

6D-12 7.8

Inward Allowable (fb/) and Factored (fb) Distributed Load (lbs/ft2)


Gage

Span

Limit
Condition

SS

fb

L/360
L/240
fb /

20

DS

fb

L/360
fb /

TS

fb

L/360
L/240
fb /

SS

L/360
L/240
fb /

18

DS

fb

L/360
L/240
fb /
fb

L/360
L/240
fb /

SS

fb

L/360
L/240
fb /

DS

fb

L/360
L/240
fb /

TS

fb

L/360
L/240
fb /
L/360
L/240
fb /

14

DS

fb

L/360
L/240

TS

fb

L/360
L/240

www.ascsd.com

81
128
49
73

231
367
215
237
376
-

170
270
135
174
276
-

130
206
91
133
211
-

103
163
64
96

297
470
282
297
471
-

218
346
178
218
346
-

167
265
119
167
265
-

132
209
84
125

33
53
13
19

29
46
11
16

42
67
17
25

37
59
14
21

54
86
22
33

47
75
18
27

Exceeds
Maximum
Product Length
65
104
36
53

54
86
27
40

45
72
21
31

39
61
16
24

Exceeds
Maximum
Product Length
83
132
46
70

69
109
35
52

58
92
27
40

49
78
21
32

Exceeds
Maximum
Product Length
107
169
61
91

88
140
46
69

74
118
35
53

63
100
28
42

Exceeds
Maximum
Product Length

Composite and Non-Composite Deck Catalog May 2014

ACUSTADEK

fb /

102
162
69
107
170
-

30' - 0"
20
32
7
11

D PANEL

SS

fb

133
211
104
140
222
-

28' - 0"
23
37
9
14

C PANELS

16

181
288
165
191
303
-

26' - 0"
27
42
11
17

N PANELS

TS

16' - 0"
70
112
49
75
119
-

B PANELS

fb

14' - 0"
92
146
73
98
155
-

2W PANELS

L/240

Panel Span (Support Spacing)


18' - 0" 20' - 0" 22' - 0" 24' - 0"
56
45
37
31
88
72
59
50
35
25
19
15
52
38
28
22

12' - 0"
125
199
116
133
211
-

3W PANELS

fb /

10' - 0"
180
286
191
304
239
379
261
414
275
436
343
545
333
529
341
541
426
677
427
677
427
678
534
848
-

GENERAL INFORMATION

159

TABLE OF CONTENTS

7.9 6D-12

Normal Weight Concrete (145 pcf)


Maximum Unshored Spans

6D-12 Shoring Table


Total Slab Depth
(in)

Volume
cy/100sf

7 1/2

0.926

1.080

8 1/2

1.235

1.389

9 1/2

1.543

10

1.698

10 1/2

1.852

11

2.006

11 1/2

2.160

Gage
20
18
16
14
20
18
16
14
20
18
16
14
20
18
16
14
20
18
16
14
20
18
16
14
20
18
16
14
20
18
16
14
20
18
16
14

145 pcf Normal Weight Concrete


Maximum Unshored Span
Slab and Deck
psf
Single
Double
39.5
17' - 0"
16' - 0"
40.6
19' - 7"
16' - 0"
41.7
20' - 10"
16' - 0"
43.1
22' - 1"
16' - 0"
45.5
16' - 3"
16' - 0"
46.6
18' - 11"
16' - 0"
47.7
20' - 2"
16' - 0"
49.2
21' - 5"
16' - 0"
51.6
15' - 7"
16' - 0"
52.7
18' - 5"
16' - 0"
53.7
19' - 7"
16' - 0"
55.2
20' - 10"
16' - 0"
57.6
14' - 11"
15' - 5"
58.7
17' - 10"
16' - 0"
59.8
19' - 1"
16' - 0"
61.2
20' - 4"
16' - 0"
63.7
14' - 4"
14' - 10"
64.7
17' - 3"
16' - 0"
65.8
18' - 8"
16' - 0"
67.3
19' - 11"
16' - 0"
69.7
13' - 10"
14' - 4"
70.8
16' - 8"
16' - 0"
71.9
18' - 3"
16' - 0"
73.3
19' - 6"
16' - 0"
75.7
13' - 4"
13' - 11"
76.8
16' - 2"
16' - 0"
77.9
17' - 11"
16' - 0"
79.4
19' - 1"
16' - 0"
81.8
12' - 11"
13' - 6"
82.9
15' - 8"
16' - 0"
84.0
17' - 7"
16' - 0"
85.4
18' - 9"
16' - 0"
87.8
12' - 6"
13' - 2"
88.9
15' - 3"
15' - 8"
90.0
17' - 2"
16' - 0"
91.4
18' - 6"
16' - 0"

Triple
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"

Shaded area the span is governed by maximum deck panel length of 32 feet; 16 feet for double span, 10 feet 8 inches for triple span.

160

Composite and Non-Composite Deck Catalog May 2014

www.ascsd.com

TABLE OF CONTENTS

6D-12 7.9

Light Weight Concrete (110 pcf)


Maximum Unshored Spans

1.080

8 1/2

1.235

1.389

9 1/2

1.543

10

1.698

10 1/2

1.852

11

2.006

11 1/2

2.160

C PANELS

0.926

Triple
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"

N PANELS

7 1/2

D PANEL

110 pcf Normal Weight Concrete


Maximum Unshored Span
Volume
cy/100sf
Single
Double
30.7
18' - 6"
16' - 0"
31.8
20' - 10"
16' - 0"
32.9
22' - 2"
16' - 0"
34.4
23' - 5"
16' - 0"
35.3
17' - 9"
16' - 0"
36.4
20' - 3"
16' - 0"
37.5
21' - 6"
16' - 0"
38.9
22' - 9"
16' - 0"
39.9
17' - 1"
16' - 0"
41.0
19' - 8"
16' - 0"
42.1
20' - 11"
16' - 0"
43.5
22' - 2"
16' - 0"
44.5
16' - 6"
16' - 0"
45.6
19' - 2"
16' - 0"
46.7
20' - 4"
16' - 0"
48.1
21' - 8"
16' - 0"
49.1
15' - 11"
16' - 0"
50.2
18' - 9"
16' - 0"
51.2
19' - 11"
16' - 0"
52.7
21' - 2"
16' - 0"
53.7
15' - 5"
15' - 11"
54.7
18' - 4"
16' - 0"
55.8
19' - 6"
16' - 0"
57.3
20' - 9"
16' - 0"
58.2
15' - 0"
15' - 5"
59.3
17' - 11"
16' - 0"
60.4
19' - 2"
16' - 0"
61.9
20' - 4"
16' - 0"
62.8
14' - 6"
15' - 0"
63.9
17' - 5"
16' - 0"
65.0
18' - 10"
16' - 0"
66.4
20' - 0"
16' - 0"
67.4
14' - 1"
14' - 8"
68.5
17' - 0"
16' - 0"
69.6
18' - 6"
16' - 0"
71.0
19' - 8"
16' - 0"

B PANELS

Gage

Slab and Deck


psf
20
18
16
14
20
18
16
14
20
18
16
14
20
18
16
14
20
18
16
14
20
18
16
14
20
18
16
14
20
18
16
14
20
18
16
14

2W PANELS

Total Slab Depth


(in)

3W PANELS

6D-12 Shoring Table

GENERAL INFORMATION

Shaded area the span is governed by maximum deck panel length of 32 feet; 16 feet for double span, 10 feet 8 inches for triple span.

ACUSTADEK

www.ascsd.com

Composite and Non-Composite Deck Catalog May 2014

161

TABLE OF CONTENTS

7.10 6DF-24

24

Panel Properties

Gage

Weight
w
psf
4.89
5.38
5.92
5.98
6.46
7.00
7.06
7.55
8.08

20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16

Compression
Gage

Area
Ae
in2/ft
1.007
1.146
1.291
1.361
1.498
1.640
1.676
1.836
1.997

20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16

Base Metal
Thickness Yield Strength
t
Fy
in
ksi
.0359/.036
33
.0359/.047
33
.0359/.059
33
.0478/.036
33
.0478/.047
33
.0478/.059
33
.0598/.036
33
.0598/.047
33
.0598/.059
33

Tensile
Strength
Fu
ksi
45
45
45
45
45
45
45
45
45

Area
Ag
in2/ft
1.298
1.458
1.619
1.580
1.740
1.901
1.862
2.022
2.182

Effective Section Modulus at Fy


Bending
Section
Modulus
Se+
in3/ft
1.476
1.508
1.532
2.198
2.250
2.288
3.004
3.077
3.132

Distance to
N.A. from
Bottom
yb
in
2.07
1.84
1.65
2.48
2.24
2.05
2.78
2.56
2.38

Section
Modulus
Sein3/ft
1.709
2.208
2.357
2.094
2.593
3.133
3.546
3.005
3.575

20

End
Interior

1"
194
197

Allowable (Rn/)
2"
4"
256
414
230
314

18

End
Interior

400
400

525
462

16

End
Interior

674
675

14

End
Interior

1141
1154

Condition

Web Crippling Constraints

162

Radius of
Gyration
r
in
2.596
2.567
2.523
2.602
2.601
2.582
2.593
2.608
2.605

Effective Moment of Inertia for Deflection


Distance to
N.A. from
Bottom
yb
in
3.92
3.56
3.22
4.00
3.73
3.46
4.01
3.81
3.60

Reactions at Supports (plf) Based on Web Crippling


Beam
Gage

Gross Section Properties


Distance to
Moment of
N.A. from
Section
Inertia
Bottom
Modulus
Ig
yb
Sg
in4/ft
in
in3/ft
8.747
2.49
0.788
9.611
2.23
4.304
10.308
2.03
5.090
10.701
2.75
3.896
11.772
2.51
4.696
12.668
2.31
5.488
12.517
2.93
4.278
13.750
2.71
5.080
14.809
0.58
1.249

Moment of
Inertia
Ie+
in4/ft
6.676
7.232
7.671
9.065
9.882
10.556
11.405
12.462
13.361

Bearing Length of Webs

Moment of
Inertia
I ein4/ft
6.693
7.856
8.948
8.371
9.671
10.951
10.069
11.457
12.870

Uniform Load Only


Id = (2Ie+Ig)/3
I+
in4/ft
7.366
8.025
8.550
9.611
10.512
11.260
11.776
12.891
13.844

Iin4/ft
7.378
8.441
9.401
9.148
10.371
11.524
10.885
12.221
13.516

8"
453
335

1"
290
301

Factored (Rn)
2"
4"
385
620
352
480

8"
680
512

839
617

954
674

600
612

788
707

1259
944

1431
1031

880
772

1394
1016

1582
1105

1011
1033

1319
1182

2091
1554

2373
1691

1478
1308

2319
1692

2628
1833

1711
1766

2216
2001

3479
2589

3941
2805

h=5.7"

r=0.125"

Composite and Non-Composite Deck Catalog May 2014

=90

www.ascsd.com

TABLE OF CONTENTS

3W PANELS

Inward Allowable (fb/) and Factored (fb) Distributed Load (lbs/ft2)


Gage

Span

Limit
Condition
fb /
L/360
L/240
fb /

20/20

DS

fb

L/360
L/240
fb /
L/360
L/240
fb /

SS

fb

L/360
L/240

20/18

DS

fb

L/360
L/240
fb /

TS

fb

L/360
fb /

SS

fb

L/360
L/240
fb /

20/16

DS

L/360
L/240
fb /

TS

fb

L/360
L/240

26' - 0"

28' - 0"

30' - 0"

194
309

135
214

99
157

76
121

60
95

49
77

40
64

34
54

29
46

25
39

22
34

55
-

40
-

30
-

23
-

18
27

15
22

12
18

225
357

156
248

115
182

88
140

70
110

56
89

199
315

138
219

101
161

78
123

61
97

50
79

41
65

34
55

29
47

25
40

22
35

60
-

44
-

33
-

25
-

20
-

16
24

13
19

291
462

202
320

148
235

114
180

90
142

73
115

202
320

140
222

103
163

79
125

62
99

50
80

42
66

35
56

30
47

26
41

22
36

47
-

35
-

27
-

21
-

17
26

14
21

310
493

216
342

158
251

121
192

96
152

78
123

Exceeds
Maximum
Product Length

281
447
-

Exceeds
Maximum
Product Length

310
493
-

315
500

Exceeds
Maximum
Product Length

D PANEL

fb

16' - 0"

C PANELS

L/240

14' - 0"

N PANELS

fb /

12' - 0"

B PANELS

TS

fb

10' - 0"

2W PANELS

SS

fb

Panel Span (Support Spacing)


18' - 0" 20' - 0" 22' - 0" 24' - 0"

GENERAL INFORMATION

6DF-24 7.11

ACUSTADEK

www.ascsd.com

Composite and Non-Composite Deck Catalog May 2014

163

TABLE OF CONTENTS

7.11 6DF-24

Inward Allowable (fb/) and Factored (fb) Distributed Load (lbs/ft2)


Gage

Span

Limit
Condition
fb /

SS

fb

L/360
L/240
fb /

18/20

DS

fb

L/360
L/240
fb /

TS

fb

L/360
L/240
fb /

SS

fb

L/360
L/240
fb /

18/18

DS

fb

L/360
L/240
fb /

TS

fb

L/360
L/240
fb /

SS

fb

L/360
L/240
fb /

18/16

DS

fb

L/360
L/240
fb /

TS

fb

L/360
L/240

164

Panel Span (Support Spacing)


16' - 0" 18' - 0" 20' - 0" 22' - 0" 24' - 0"

10' - 0"

12' - 0"

14' - 0"

26' - 0"

28' - 0"

30' - 0"

290
459

201
319

148
234

113
179

89
142

72
115

60
95

50
80

43
68

37
59

32
51

103
-

72
-

53
-

39
59

30
46

24
36

19
29

16
23

276
438

192
304

141
223

108
171

85
135

69
109

296
470

206
327

151
240

116
184

91
145

74
118

61
97

51
82

44
70

38
60

33
52

112
-

79
-

57
-

43
-

33
50

26
39

21
31

17
26

342
542

237
376

174
276

133
212

105
167

85
135

301
478

209
332

154
244

118
187

93
148

75
120

62
99

52
83

45
71

38
61

33
53

84
-

62
-

46
-

36
-

28
42

22
34

18
27

413
655

287
455

211
334

161
256

127
202

103
164

Exceeds
Maximum
Product Length

345
547
-

Exceeds
Maximum
Product Length

427
677
-

471
747

Exceeds
Maximum
Product Length

Composite and Non-Composite Deck Catalog May 2014

www.ascsd.com

TABLE OF CONTENTS

3W PANELS

Inward Allowable (fb/) and Factored (fb) Distributed Load (lbs/ft2)


Gage

Span

Limit
Condition
fb /

SS

L/360
L/240
fb /

16/20

DS

fb

L/360
L/240
fb /
L/360
L/240
fb /

SS

fb

L/360
L/240

16/18

DS

fb

L/360
L/240
fb /

TS

fb

L/360

SS

fb

L/360
L/240
fb /

16/16

DS

L/360
L/240
fb /

TS

fb

L/360
L/240

28' - 0"

30' - 0"

155
245

122
194

99
157

82
130

69
109

59
93

50
80

44
70

188
-

126
-

88
-

64
96

48
72

37
56

29
44

23
35

19
29

467
741

324
515

238
378

182
289

144
229

117
185

405
643

281
447

207
328

158
251

125
198

101
161

84
133

70
112

60
95

52
82

45
71

205
-

138
-

97
-

70
-

53
79

41
61

32
48

26
38

21
31

396
628

275
436

202
320

155
245

122
194

99
157

413
655

287
455

211
334

161
256

127
202

103
164

85
135

72
114

61
97

53
83

46
73

148
-

104
-

76
-

57
85

44
66

34
52

28
41

22
34

471
747

327
519

240
381

184
292

145
231

118
187

Exceeds
Maximum
Product Length

584
926
-

Exceeds
Maximum
Product Length

495
785
-

589
934

Exceeds
Maximum
Product Length

D PANEL

fb

26' - 0"

202
320

C PANELS

L/240
fb /

14' - 0"

275
436

N PANELS

fb /

12' - 0"

396
628

B PANELS

TS

fb

10' - 0"

2W PANELS

fb

Panel Span (Support Spacing)


16' - 0" 18' - 0" 20' - 0" 22' - 0" 24' - 0"

GENERAL INFORMATION

6DF-24 7.11

ACUSTADEK

www.ascsd.com

Composite and Non-Composite Deck Catalog May 2014

165

TABLE OF CONTENTS

7.12 6DF-24

Normal Weight Concrete (145 pcf)


Maximum Unshored Spans

6DF-24 Shoring Table


Total Slab Depth
(in)

Volume
cy/100sf

7 1/2

0.937

8 1/2

1.246

9 1/2

1.554

10 1/2

1.863

11 1/2

2.171

Gage
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16

145 pcf Normal Weight Concrete


Maximum Unshored Span
Slab and Deck
psf
Single
Double
41.5
17' - 4"
18' - 8"
42.1
17' - 6"
19' - 11"
42.7
17' - 6"
20' - 0"
42.6
21' - 0"
20' - 0"
43.1
21' - 2"
20' - 0"
43.8
21' - 3"
20' - 0"
43.6
22' - 2"
20' - 0"
44.2
22' - 7"
20' - 0"
44.9
23' - 1"
20' - 0"
53.6
15' - 11"
17' - 2"
54.1
16' - 1"
18' - 4"
54.8
16' - 1"
18' - 5"
54.6
19' - 4"
18' - 10"
55.2
19' - 6"
20' - 0"
55.9
19' - 7"
20' - 0"
55.7
20' - 11"
20' - 0"
56.3
21' - 4"
20' - 0"
57.0
21' - 10"
20' - 0"
65.6
14' - 9"
15' - 11"
66.2
14' - 11"
17' - 0"
66.9
15' - 0"
17' - 1"
66.7
18' - 0"
17' - 6"
67.3
18' - 1"
19' - 5"
68.0
18' - 2"
20' - 0"
67.8
19' - 11"
20' - 0"
68.4
20' - 4"
20' - 0"
69.0
20' - 10"
20' - 0"
77.7
13' - 9"
14' - 11"
78.3
13' - 11"
16' - 0"
79.0
14' - 0"
16' - 1"
78.8
16' - 10"
16' - 6"
79.4
17' - 0"
18' - 3"
80.0
17' - 1"
19' - 6"
79.9
19' - 2"
20' - 0"
80.5
19' - 7"
19' - 7"
81.1
19' - 11"
20' - 0"
89.8
12' - 11"
14' - 2"
90.4
13' - 1"
15' - 1"
91.0
13' - 2"
15' - 2"
90.9
15' - 11"
15' - 7"
91.5
16' - 1"
17' - 3"
92.1
16' - 2"
18' - 6"
92.0
18' - 7"
20' - 0"
92.6
18' - 9"
18' - 6"
93.2
18' - 10"
20' - 0"

Triple
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"

Shaded area the span is governed by maximum deck panel length of 32 feet; 16 feet for double span, 10 feet 8 inches for triple span.

166

Composite and Non-Composite Deck Catalog May 2014

www.ascsd.com

TABLE OF CONTENTS

Light Weight Concrete (110 pcf)


Maximum Unshored Spans

1.246

9 1/2

1.554

10 1/2

1.863

11 1/2

2.171

D PANEL

8 1/2

C PANELS

0.937

Triple
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"

N PANELS

7 1/2

ACUSTADEK

Gage
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16

110 pcf Light Weight Concrete


Maximum Unshored Span
Slab and Deck
psf
Single
Double
32.6
18' - 10"
20' - 0"
33.2
19' - 0"
20' - 0"
33.8
19' - 0"
20' - 0"
33.7
22' - 4"
20' - 0"
34.3
22' - 9"
20' - 0"
34.9
23' - 0"
20' - 0"
34.8
23' - 6"
20' - 0"
35.4
23' - 11"
20' - 0"
36.0
24' - 6"
20' - 0"
41.8
17' - 5"
18' - 9"
42.4
17' - 7"
20' - 0"
43.0
17' - 7"
20' - 0"
42.9
21' - 1"
20' - 0"
43.5
21' - 3"
20' - 0"
44.1
21' - 4"
20' - 0"
44.0
22' - 3"
20' - 0"
44.5
22' - 8"
20' - 0"
45.2
23' - 2"
20' - 0"
51.0
16' - 4"
17' - 7"
51.5
16' - 5"
18' - 9"
52.2
16' - 6"
18' - 10"
52.1
19' - 9"
19' - 4"
52.6
19' - 11"
20' - 0"
53.2
20' - 0"
20' - 0"
53.1
21' - 3"
20' - 0"
53.7
21' - 8"
20' - 0"
54.3
22' - 2"
20' - 0"
60.1
15' - 5"
16' - 7"
60.7
15' - 6"
17' - 8"
61.3
15' - 7"
17' - 9"
61.2
18' - 8"
18' - 2"
61.8
18' - 10"
20' - 0"
62.4
18' - 11"
20' - 0"
62.3
20' - 5"
20' - 0"
62.9
20' - 10"
20' - 0"
63.5
21' - 4"
20' - 0"
69.3
14' - 7"
15' - 8"
69.9
14' - 8"
16' - 9"
70.5
14' - 9"
16' - 10"
70.4
17' - 8"
17' - 3"
71.0
17' - 10"
19' - 2"
71.6
17' - 11"
20' - 0"
71.5
19' - 9"
20' - 0"
72.0
20' - 2"
20' - 0"
72.7
20' - 8"
20' - 0"

B PANELS

Volume
cy/100sf

2W PANELS

Total Slab Depth


(in)

3W PANELS

6DF-24 Shoring Table

Shaded area the span is governed by maximum deck panel length of 32 feet; 16 feet for double span, 10 feet 8 inches for triple span.

www.ascsd.com

GENERAL INFORMATION

6DF-24 7.12

Composite and Non-Composite Deck Catalog May 2014

167

TABLE OF CONTENTS

7.13 7.5D-12
9

7-1/2

12
2 Welds

Panel Properties

Gage

Weight
w
psf
3.60
4.80
6.00
7.60

20
18
16
14

Compression
Gage

Area
Ae
in2/ft
0.519
0.816
1.154
1.661

20
18
16
14

Base Metal
Thickness Yield Strength
t
Fy
in
ksi
0.0359
33
0.0478
33
0.0598
33
0.075
33

Tensile
Strength
Fu
ksi
45
45
45
45

Area
Ag
in2/ft
1.058
1.414
1.768
2.235

Effective Section Modulus at Fy


Bending
Section
Modulus
Se+
in3/ft
1.718
2.702
3.454
4.440

Distance to
N.A. from
Bottom
yb
in
3.50
3.87
4.05
4.23

Section
Modulus
Sein3/ft
1.791
2.548
3.316
4.360

20

End
Interior

1"
169
171

Allowable (Rn/)
2"
4"
223
360
200
273

18

End
Interior

361
361

474
417

16

End
Interior

620
621

14

End
Interior

1065
1077

Condition

Web Crippling Constraints

168

Radius of
Gyration
r
in
2.931
2.924
2.917
2.908

Effective Moment of Inertia for Deflection


Distance to
N.A. from
Bottom
yb
in
4.60
4.47
4.38
4.29

Reactions at Supports (plf) Based on Web Crippling


Beam
Gage

Gross Section Properties


Distance to
Moment of
N.A. from
Section
Inertia
Bottom
Modulus
Ig
yb
Sg
in4/ft
in
in3/ft
9.088
4.23
2.148
12.089
4.24
2.853
15.040
4.24
3.547
18.900
4.25
4.451

Moment of
Inertia
Ie+
in4/ft
6.863
10.457
14.003
18.778

Bearing Length of Webs

Moment of
Inertia
I ein4/ft
8.231
11.389
14.524
18.700

Uniform Load Only


Id = (2Ie+Ig)/3
I+
in4/ft
7.605
11.001
14.349
18.819

Iin4/ft
8.517
11.622
14.696
18.767

8"
395
292

1"
253
262

Factored (Rn)
2"
4"
335
540
307
418

8"
592
446

757
557

861
608

541
552

711
638

1136
852

1291
931

809
710

1282
934

1455
1016

930
950

1213
1087

1923
1430

2182
1555

1380
1221

2166
1580

2453
1711

1598
1648

2069
1868

3248
2417

3680
2619

h=7.2"

r=0.125"

Composite and Non-Composite Deck Catalog May 2014

=90

www.ascsd.com

TABLE OF CONTENTS

7.5D-12 7.14

Inward Allowable (fb/) and Factored (fb) Distributed Load (lbs/ft2)


Gage

Span

Limit
Condition

SS

fb

L/360
L/240
fb /

20

DS

fb

L/360
fb /

TS

fb

L/360
L/240
fb /

SS

L/360
L/240
fb /

18

DS

fb

L/360
L/240
fb /
fb

L/360
L/240
fb /

SS

fb

L/360
L/240
fb /

DS

fb

L/360
L/240
fb /

TS

fb

L/360
L/240
fb /
L/360
L/240
fb /

14

DS

fb

L/360
L/240

TS

fb

L/360
L/240

www.ascsd.com

110
174
82
-

316
501
303
481
-

232
368
229
223
354
-

178
282
153
171
271
-

140
223
108
-

406
644
399
633
-

298
473
293
465
-

228
362
201
224
356
-

181
286
141
-

45
72
22
33

40
63
18
27

58
92
29
43

51
80
23
35

75
118
37
56

65
103
30
46

Exceeds
Maximum
Product Length
89
141
60
-

74
117
45
68

62
98
35
52

53
84
27
41

Exceeds
Maximum
Product Length
114
180
78
-

94
149
59
88

79
125
45
68

67
107
36
54

Exceeds
Maximum
Product Length
146
232
103
-

121
192
77
116

102
161
59
89

87
137
47
70

Exceeds
Maximum
Product Length

Composite and Non-Composite Deck Catalog May 2014

ACUSTADEK

fb /

139
221
117
131
208
-

30' - 0"
25
40
12
18

D PANEL

SS

fb

182
288
175
171
272
-

28' - 0"
29
46
15
23

C PANELS

16

247
392
233
370
-

26' - 0"
33
53
19
28

N PANELS

TS

16' - 0"
88
140
81
92
146
-

B PANELS

fb

14' - 0"
115
183
120
191
-

2W PANELS

L/240

Panel Span (Support Spacing)


18' - 0" 20' - 0" 22' - 0" 24' - 0"
70
57
47
39
111
90
74
62
57
42
31
24
36

12' - 0"
157
249
164
260
-

3W PANELS

fb /

10' - 0"
226
359
236
374
295
468
356
565
336
532
420
666
455
722
437
693
546
866
585
928
574
911
718
1139
-

GENERAL INFORMATION

169

TABLE OF CONTENTS

7.15 7.5D-12

Normal Weight Concrete (145 pcf)


Maximum Unshored Spans

7.5D-12 Shoring Table


Total Slab Depth
(in)

Volume
cy/100sf

1.042

9 1/2

1.196

10

1.350

10 1/2

1.505

11

1.659

11 1/2

1.813

12

1.968

12 1/2

2.122

13

2.276

Gage
20
18
16
14
20
18
16
14
20
18
16
14
20
18
16
14
20
18
16
14
20
18
16
14
20
18
16
14
20
18
16
14
20
18
16
14

145 pcf Normal Weight Concrete


Maximum Unshored Span
Slab and Deck
psf
Single
Double
44.4
18' - 4"
16' - 0"
45.6
21' - 9"
16' - 0"
46.8
23' - 1"
16' - 0"
48.4
24' - 6"
16' - 0"
50.4
17' - 7"
16' - 0"
51.6
21' - 1"
16' - 0"
52.8
22' - 5"
16' - 0"
54.4
23' - 10"
16' - 0"
56.5
16' - 11"
16' - 0"
57.7
20' - 7"
16' - 0"
58.9
21' - 10"
16' - 0"
60.5
23' - 3"
16' - 0"
62.5
16' - 3"
16' - 0"
63.7
20' - 1"
16' - 0"
64.9
21' - 4"
16' - 0"
66.5
22' - 9"
16' - 0"
68.5
15' - 9"
16' - 0"
69.7
19' - 7"
16' - 0"
70.9
20' - 11"
16' - 0"
72.5
22' - 3"
16' - 0"
74.6
15' - 3"
15' - 7"
75.8
19' - 0"
16' - 0"
77.0
20' - 6"
16' - 0"
78.6
21' - 10"
16' - 0"
80.6
14' - 9"
15' - 1"
81.8
18' - 5"
16' - 0"
83.0
20' - 2"
16' - 0"
84.6
21' - 5"
16' - 0"
86.7
14' - 4"
14' - 8"
87.9
17' - 11"
16' - 0"
89.1
19' - 10"
16' - 0"
90.7
21' - 1"
16' - 0"
92.7
13' - 11"
14' - 3"
93.9
17' - 5"
16' - 0"
95.1
19' - 6"
16' - 0"
96.7
20' - 9"
16' - 0"

Triple
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"

Shaded area the span is governed by maximum deck panel length of 32 feet; 16 feet for double span, 10 feet 8 inches for triple span.

170

Composite and Non-Composite Deck Catalog May 2014

www.ascsd.com

TABLE OF CONTENTS

7.5D-12 7.15

Light Weight Concrete (110 pcf)


Maximum Unshored Spans

9 1/2

1.196

10

1.350

10 1/2

1.505

11

1.659

11 1/2

1.813

12

1.968

12 1/2

2.122

13

2.276

C PANELS

1.042

Triple
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"

N PANELS

D PANEL

Gage
20
18
16
14
20
18
16
14
20
18
16
14
20
18
16
14
20
18
16
14
20
18
16
14
20
18
16
14
20
18
16
14
20
18
16
14

145 pcf Light Weight Concrete


Maximum Unshored Span
Slab and Deck
psf
Single
Double
34.5
20' - 0"
16' - 0"
35.7
23' - 2"
16' - 0"
36.9
24' - 7"
16' - 0"
38.5
26' - 0"
16' - 0"
39.1
19' - 3"
16' - 0"
40.3
22' - 6"
16' - 0"
41.5
23' - 10"
16' - 0"
43.1
25' - 4"
16' - 0"
43.7
18' - 7"
16' - 0"
44.9
21' - 11"
16' - 0"
46.1
23' - 3"
16' - 0"
47.7
24' - 9"
16' - 0"
48.3
17' - 11"
16' - 0"
49.5
21' - 5"
16' - 0"
50.7
22' - 9"
16' - 0"
52.3
24' - 2"
16' - 0"
52.9
17' - 5"
16' - 0"
54.1
21' - 0"
16' - 0"
55.3
22' - 3"
16' - 0"
56.9
23' - 8"
16' - 0"
57.5
16' - 11"
16' - 0"
58.7
20' - 7"
16' - 0"
59.9
21' - 10"
16' - 0"
61.5
23' - 3"
16' - 0"
62.0
16' - 5"
16' - 0"
63.2
20' - 2"
16' - 0"
64.4
21' - 6"
16' - 0"
66.0
22' - 10"
16' - 0"
66.6
16' - 0"
16' - 0"
67.8
19' - 10"
16' - 0"
69.0
21' - 1"
16' - 0"
70.6
22' - 6"
16' - 0"
71.2
15' - 7"
15' - 11"
72.4
19' - 5"
16' - 0"
73.6
20' - 10"
16' - 0"
75.2
22' - 2"
16' - 0"

B PANELS

Volume
cy/100sf

2W PANELS

Total Slab Depth


(in)

3W PANELS

4.5D-12 Shoring Table

GENERAL INFORMATION

Shaded area the span is governed by maximum deck panel length of 32 feet; 16 feet for double span, 10 feet 8 inches for triple span.

ACUSTADEK

www.ascsd.com

Composite and Non-Composite Deck Catalog May 2014

171

TABLE OF CONTENTS

7.16 7.5DF-24

7-1/2

24
RD33

7-1/2 Deep Deck Cellular

Panel Properties

Gage

Weight
w
psf
5.24
5.73
6.27
6.44
6.93
7.47
7.64
8.13
8.67

20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16

Compression
Gage

Area
Ae
in2/ft
1.056
1.191
1.332
1.456
1.589
1.728
1.853
1.998
2.136

20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16

Base Metal
Thickness Yield Strength
t
Fy
in
ksi
.0359/.036
33
.0359/.047
33
.0359/.059
33
.0478/.036
33
.0478/.047
33
.0478/.059
33
.0598/.036
33
.0598/.047
33
.0598/.059
33

Tensile
Strength
Fu
ksi
45
45
45
45
45
45
45
45
45

Area
Ag
in2/ft
1.403
1.563
1.724
1.721
1.881
2.042
2.039
2.199
2.359

Effective Section Modulus at Fy


Bending
Section
Modulus
Se+
in3/ft
1.821
2.048
2.087
2.936
3.017
3.078
3.977
4.087
4.172

Distance to
N.A. from
Bottom
yb
in
2.61
2.40
2.17
3.16
2.88
2.65
3.51
3.25
3.03

Section
Modulus
Sein3/ft
2.252
2.890
3.119
2.824
3.429
4.077
3.396
4.000
4.687

Condition

Distance to
N.A. from
Bottom
yb
in
4.84
4.40
4.03
4.85
4.58
4.30
4.87
4.66
4.44

Moment of
Inertia
Ie+
in4/ft
10.687
11.874
12.639
14.741
16.088
17.215
18.505
20.203
21.667

Bearing Length of Webs

Moment of
Inertia
I ein4/ft
10.905
12.701
14.417
13.702
15.694
17.683
16.533
18.647
20.823

Uniform Load Only


Id = (2Ie+Ig)/3
I+
in4/ft
11.859
13.117
14.010
15.624
17.092
18.326
19.128
20.909
22.448

Iin4/ft
12.005
13.669
15.195
14.932
16.829
18.638
17.813
19.872
21.886

8"
395
292

1"
253
262

Factored (Rn)
2"
4"
335
540
307
418

8"
592
446

20

End
Interior

1"
169
171

18

End
Interior

361
361

474
417

757
557

861
608

541
552

711
638

1136
852

1291
931

16

End
Interior

620
621

809
710

1282
934

1455
1016

930
950

1213
1087

1923
1430

2182
1555

14

End
Interior

1065
1077

1380
1221

2166
1580

2453
1711

1598
1648

2069
1868

3248
2417

3680
2619

Web Crippling Constraints

172

Allowable (Rn/)
2"
4"
223
360
200
273

Radius of
Gyration
r
in
3.182
3.159
3.117
3.179
3.186
3.172
3.660
3.186
3.190

Effective Moment of Inertia for Deflection

Reactions at Supports (plf) Based on Web Crippling


Beam
Gage

Gross Section Properties


Distance to
Moment of
N.A. from
Section
Inertia
Bottom
Modulus
Ig
yb
Sg
in4/ft
in
in3/ft
14.204
3.16
4.502
15.605
2.84
5.486
16.751
2.59
6.460
17.391
3.45
5.040
19.100
3.17
6.027
20.549
2.93
7.007
20.374
3.66
5.573
22.320
3.40
6.562
24.010
3.18
7.544

h=7.2"

r=0.125"

Composite and Non-Composite Deck Catalog May 2014

=90

www.ascsd.com

TABLE OF CONTENTS

7.5DF-24 7.17

Gage

Span

Limit
Condition
fb /

SS

fb

L/360
fb /

20/20

DS

fb

L/360
L/240
fb /
L/360
L/240
fb /

SS

fb

L/360
L/240
fb /

DS

L/360
L/240
fb /

TS

fb

L/360
L/240

SS

fb

L/360
L/240
fb /

20/16

DS

fb

L/360
fb /

TS

fb

L/360

28' - 0"

30' - 0"

240
381

167
264

122
194

94
149

74
117

60
95

50
79

42
66

35
56

31
49

27
42

49
-

37
-

29
-

24
-

19
-

297
471

206
327

151
240

116
184

92
145

74
118

270
428

187
297

138
218

105
167

83
132

67
107

56
88

47
74

40
63

34
55

30
48

54
-

41
-

33
-

26
-

21
-

381
604

264
419

194
308

149
236

118
186

95
151

275
436

191
303

140
223

107
170

85
135

69
109

57
90

48
76

41
65

35
56

31
48

44
-

35
-

28
-

23
-

411
652

285
453

210
333

161
255

127
201

103
163

Exceeds
Maximum
Product Length

371
588
-

Exceeds
Maximum
Product Length

422
669
-

430
682

Exceeds
Maximum
Product Length

D PANEL

L/240

26' - 0"

C PANELS

fb /

16' - 0"

N PANELS

20/18

fb

14' - 0"

B PANELS

TS

fb

12' - 0"

2W PANELS

L/240

Panel Span (Support Spacing)


18' - 0" 20' - 0" 22' - 0" 24' - 0"

10' - 0"

3W PANELS

Inward Allowable (fb/) and Factored (fb) Distributed Load (lbs/ft2)

GENERAL INFORMATION

ACUSTADEK

www.ascsd.com

Composite and Non-Composite Deck Catalog May 2014

173

TABLE OF CONTENTS

7.17 7.5DF-24

Normal Weight Concrete (145 pcf)


Maximum Unshored Spans

Inward Allowable (fb/) and Factored (fb) Distributed Load (lbs/ft2)


Gage

Span

Limit
Condition
fb /

SS

fb

L/360
L/240
fb /

18/20

DS

fb

L/360
L/240
fb /

TS

fb

L/360
L/240
fb /

SS

fb

L/360
L/240
fb /

18/18

DS

fb

L/360
L/240
fb /

TS

fb

L/360
L/240
fb /

SS

fb

L/360
L/240
fb /

18/16

DS

fb

L/360
L/240
fb /

TS

174

fb

L/360

Panel Span (Support Spacing)


16' - 0" 18' - 0" 20' - 0" 22' - 0" 24' - 0"

10' - 0"

12' - 0"

14' - 0"

26' - 0"

28' - 0"

30' - 0"

387
614

269
426

197
313

151
240

119
189

97
153

80
127

67
107

57
91

49
78

43
68

117
-

85
-

64
-

49
-

39
-

31
47

25
38

372
590

258
410

190
301

145
231

115
182

93
148

397
631

276
438

203
322

155
246

123
195

99
158

82
130

69
109

59
93

51
80

44
70

93
-

70
-

54
-

43
-

34
-

28
41

452
717

314
498

230
366

176
280

139
221

113
179

406
643

282
447

207
328

158
251

125
199

101
161

84
133

70
112

60
95

52
82

45
71

100
-

75
-

58
-

46
-

36
-

30
44

537
852

373
592

274
435

210
333

166
263

134
213

Exceeds
Maximum
Product Length

465
738
-

Exceeds
Maximum
Product Length

565
896
-

634
1005

Exceeds
Maximum
Product Length

Composite and Non-Composite Deck Catalog May 2014

www.ascsd.com

TABLE OF CONTENTS

7.5DF-24 7.17

Light Weight Concrete (110 pcf)


Maximum Unshored Spans

3W PANELS

Inward Allowable (fb/) and Factored (fb) Distributed Load (lbs/ft2)


Gage

Span

Limit
Condition
fb /

SS

L/360
L/240
fb /

16/20

DS

fb

L/360
L/240
fb /
L/360
L/240
fb /

SS

fb

L/360
L/240

16/18

DS

fb

L/360
L/240
fb /

TS

fb

L/360

SS

fb

L/360
L/240
fb /

16/16

DS

L/360
L/240
fb /

TS

fb

L/360

28' - 0"

30' - 0"

205
325

162
257

131
208

108
172

91
144

77
123

67
106

58
92

204
-

143
-

104
-

79
-

60
91

48
71

38
57

31
46

447
710

311
493

228
362

175
277

138
219

112
177

538
854

374
593

275
436

210
334

166
264

135
214

111
176

93
148

80
126

69
109

60
95

157
-

114
-

86
-

66
-

52
78

42
62

34
51

527
836

366
581

269
426

206
327

163
258

132
209

550
872

382
606

280
445

215
341

170
269

137
218

114
180

95
151

81
129

70
111

61
97

168
-

123
-

92
-

71
-

56
-

45
67

36
55

617
979

429
680

315
500

241
383

191
302

154
245

Exceeds
Maximum
Product Length

559
887
-

Exceeds
Maximum
Product Length

659
1045
-

772
1224

Exceeds
Maximum
Product Length

D PANEL

fb

26' - 0"

267
424

C PANELS

L/240
fb /

14' - 0"

364
577

N PANELS

fb /

12' - 0"

524
831

B PANELS

TS

fb

10' - 0"

2W PANELS

fb

Panel Span (Support Spacing)


16' - 0" 18' - 0" 20' - 0" 22' - 0" 24' - 0"

GENERAL INFORMATION

ACUSTADEK

www.ascsd.com

Composite and Non-Composite Deck Catalog May 2014

175

TABLE OF CONTENTS

7.18 7.5DF-24

Normal Weight Concrete (145 pcf)


Maximum Unshored Spans

7.5DF-24 Shoring Table


Total Slab Depth
(in)

Volume
cy/100sf

1.053

10

1.361

11

1.670

12

1.979

13

2.287

Gage
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16

145 pcf Normal Weight Concrete


Maximum Unshored Span
Slab and Deck
psf
Single
Double
46.3
18' - 7"
20' - 0"
46.9
19' - 8"
20' - 0"
47.6
19' - 9"
20' - 0"
47.6
23' - 5"
20' - 0"
48.1
23' - 8"
20' - 0"
48.8
23' - 9"
20' - 0"
48.8
24' - 7"
20' - 0"
49.3
25' - 1"
20' - 0"
50.0
25' - 5"
20' - 0"
58.4
17' - 2"
19' - 1"
59.0
18' - 2"
20' - 0"
59.7
18' - 3"
20' - 0"
59.6
21' - 8"
20' - 0"
60.2
21' - 10"
20' - 0"
60.9
22' - 0"
20' - 0"
60.8
23' - 4"
20' - 0"
61.4
23' - 9"
20' - 0"
62.1
24' - 2"
20' - 0"
70.5
16' - 0"
17' - 10"
71.1
16' - 11"
19' - 4"
71.7
17' - 0"
19' - 5"
71.7
20' - 2"
19' - 10"
72.3
20' - 5"
20' - 0"
72.9
20' - 7"
20' - 0"
72.9
22' - 4"
20' - 0"
73.5
22' - 9"
20' - 0"
74.1
23' - 2"
20' - 0"
82.6
15' - 1"
16' - 9"
83.2
15' - 11"
18' - 2"
83.8
16' - 1"
18' - 4"
83.8
19' - 0"
18' - 8"
84.4
19' - 3"
20' - 0"
85.0
19' - 4"
20' - 0"
85.0
21' - 6"
20' - 0"
85.6
21' - 11"
20' - 0"
86.2
22' - 4"
20' - 0"
94.7
14' - 3"
15' - 11"
95.3
15' - 1"
17' - 3"
95.9
15' - 2"
17' - 4"
95.9
18' - 0"
17' - 8"
96.5
18' - 3"
19' - 5"
96.5
18' - 3"
19' - 5"
97.1
20' - 10"
19' - 4"
97.7
21' - 1"
20' - 0"
98.3
21' - 3"
20' - 0"

Triple
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"

Shaded area the span is governed by maximum deck panel length of 32 feet; 16 feet for double span, 10 feet 8 inches for triple span.

176

Composite and Non-Composite Deck Catalog May 2014

www.ascsd.com

TABLE OF CONTENTS

7.5DF-24 7.18

Light Weight Concrete (110 pcf)


Maximum Unshored Spans

1.361

11

1.670

12

1.979

13

2.287

D PANEL

10

C PANELS

1.053

Triple
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"
10' - 8"

N PANELS

ACUSTADEK

Gage
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16
20/20
20/18
20/16
18/20
18/18
18/16
16/20
16/18
16/16

145 pcf Light Weight Concrete


Maximum Unshored Span
Slab and Deck
psf
Single
Double
36.4
20' - 4"
20' - 0"
37.0
21' - 5"
20' - 0"
37.6
21' - 7"
20' - 0"
37.6
25' - 0"
20' - 0"
38.2
25' - 5"
20' - 0"
38.8
25' - 9"
20' - 0"
38.8
26' - 1"
20' - 0"
39.4
26' - 7"
20' - 0"
40.0
26' - 11"
20' - 0"
45.6
18' - 10"
20' - 0"
46.2
19' - 11"
20' - 0"
46.8
20' - 0"
20' - 0"
46.8
23' - 8"
20' - 0"
47.4
23' - 11"
20' - 0"
48.0
24' - 1"
20' - 0"
48.0
24' - 9"
20' - 0"
48.6
25' - 3"
20' - 0"
49.2
25' - 8"
20' - 0"
54.8
17' - 8"
19' - 8"
55.3
18' - 8"
20' - 0"
55.9
18' - 9"
20' - 0"
56.0
22' - 3"
20' - 0"
56.5
22' - 6"
20' - 0"
57.1
22' - 8"
20' - 0"
57.2
23' - 9"
20' - 0"
57.7
24' - 3"
20' - 0"
58.3
24' - 7"
20' - 0"
63.9
16' - 9"
18' - 7"
64.5
17' - 8"
20' - 0"
65.1
17' - 9"
20' - 0"
65.1
21' - 1"
20' - 0"
65.7
21' - 3"
20' - 0"
66.3
21' - 5"
20' - 0"
66.3
22' - 11"
20' - 0"
66.9
23' - 5"
20' - 0"
67.5
23' - 9"
20' - 0"
73.1
15' - 11"
17' - 8"
73.7
16' - 10"
19' - 2"
74.3
16' - 11"
19' - 3"
74.3
20' - 0"
19' - 8"
74.9
20' - 3"
20' - 0"
75.5
20' - 5"
20' - 0"
75.5
22' - 2"
20' - 0"
76.1
22' - 8"
20' - 0"
76.7
23' - 0"
20' - 0"

B PANELS

Volume
cy/100sf

2W PANELS

Total Slab Depth


(in)

3W PANELS

7.5DF-24 Shoring Table

Shaded area the span is governed by maximum deck panel length of 32 feet; 16 feet for double span, 10 feet 8 inches for triple span.

www.ascsd.com

GENERAL INFORMATION

Composite and Non-Composite Deck Catalog May 2014

177

TABLE OF CONTENTS

8.1 Acustadek
Acustadek
Acustadek provides the extraordinary beauty of exposed steel,
while providing the same noise reduction performance of
common Mineral Fiber, Fiberglass, and Bio Acoustic ceiling
tile systems. It is an excellent option for reducing noise
inside buildings, increasing the comfort for the occupants.
Acustadek is a dual-purpose panel that helps lower costs
by providing an interior finish while contributing to the
structural performance of the building. This is accomplished
by perforating the structural steel decks and adding fiberglass
batt acoustic media in the webs or in the cells of cellular deck,
turning the profile into Acustadek.
Cellular Acustadek
Cellular Acustadek has 0.157 diameter holes spaced 0.433
inches on center in the sections of the pan below the top
flutes of the steel deck. Fiberglass batts are factory inserted in
the cells of the deck before shipping to the project locations.
Any roof system utilizing structural or insulating concrete
fill, rigid insulation board, or other roof substrate material
suitable for installation on a steel roof deck may be applied
to the cellular Acustadek.

of audible sound. In buildings with equipment that creates a


specific frequency, the sound absorption coefficient for that
frequency range should determine the type of deck rather than
the overall NRC rating.
The NRC should not be confused with the Sound Transmission
Coefficient (STC). STCs measure the blocking of sound through
an assembly as it relates to the decibel drop in the intensity of
the sound. Acustadek may not be a good choice if a high STC is
required. As an example, consider a room with noisy equipment.
The Acustadek may be a good solution to reduce the noise level
in the room for the occupants, but may not be a good material
to block the noise from escaping the room. The holes in the
perforated Acustadek may in fact let more sound escape the
room than a conventional deck.
Detailing and Installation of Acustadek
Acustadek provides an exposed finish in the building. Steel deck
is a structural element in the building and is subject to incidental
dents in the handling and steel erection process. To minimize
the potential damage, use 20 gage or heavier. 22 gage may be
an economical option when minor dents can be tolerated; dark
paint finishes or high roof structures can mask these types of
minor blemishes.
Acustadek can be specified with a galvanized finish or factory
prime painted over galvanized steel. Most Acustadeks will receive
finish paint to meet the aesthetic requirements of the building.
The galvanized steel can be field painted following the paint
manufacturers preparation and application recommendations.
As an option, factory-applied primer can be specified, which
may reduce the surface preparation of the deck.

Fiberglass Batts
Fiberglass batts are used to absorb sound in the Acustadek
assemblies. ASC Steel Deck supplies the fiberglass batts that
are cut to size for the specified profile. The standard batts are
unfaced. Optional batts encapsulated with 0.75 mil clear pvc
plastic can be specified.
Acoustical Performance
All Acustadeks have been tested for the sound absorption
characteristics of the assemblies. This is commonly presented
as a Noise Reduction Coefficient (NRC). The NRC is the average
of the 250, 500, 1000, and 2000 hertz sound absorption
coefficients. Acustadeks have between a 0.6 and 1.0 NRC.
Acustadek should be a portion of a holistic approach to
reducing the noise level in a building. Simply specifying
an NRC rating for a single material may not get the level
of sound control you require. In general, steel decks tend
to have better sound absorption coefficients in the higher
audible range. Other materials such as fabric wall treatments
and carpet tend to have better sound absorption coefficients
in the lower audible frequency ranges. The use of Acustadek
in combination with other materials may create the best
overall quiet environment. An experienced acoustic designer
is key to developing the best overall performance using ASC
Steel Deck Acustadek products.
The sound absorption coefficient varies across the spectrum

178

Attaching the Acustadek to the structure and connection of the


side laps of the deck can impact the appearance of the installed
product. Side lap top seam welds will leave burn marks on
the galvanized finish and an occasional burn through should
be expected. This may be unsightly if the galvanized finish is
intended to be left exposed. The burns can be easily cleaned
up prior to prime painting the deck after installation. A better
solution is to use the DeltaGrip side lap connection. This
mechanical interlock connection provides high strength similar
to a weld without any thermal damage to the deck or galvanized
coating, and is not visible from the underside of the deck. Arc
spot and arc seam welds may also leave visible burn marks on
the deck near the support or on the underside of the supporting
steel. A good alternative to welding the deck to supports is
to attach the deck with self-drilling screws or power-actuated
fasteners (PAF), such as the high shear nails manufactured by
Hilti, Inc. or fasteners manufactured by Pneutek Inc. that are
intended for decking applications.
Structural Performance of Acustadek
The perforation of the pans of the Acustadeks has a small impact
on the structural performance of the deck profiles. Section
properties are reduced from the non-Acustadek version of the
profiles leading to reduced vertical load capacity. The reactions
at supports are unaffected by the perforations in the Acustadek.

Composite and Non-Composite Deck Catalog May 2014

www.ascsd.com

TABLE OF CONTENTS

Sound Absorption Data


Absorption Coefficient1

Acustadek Profile

(Perforation Type)

1000 Hz 2000 Hz 4000 Hz

Noise Reduction
Coefficient1

125 Hz

250 Hz

500 Hz

Unfaced

0.20

0.45

0.77

1.09

0.84

0.56

0.80

Encapsulated

0.16

0.37

0.70

1.01

0.64

0.49

0.70

Unfaced

0.44

0.57

1.08

1.00

0.82

0.63

0.85

Encapsulated

0.49

0.63

1.17

0.93

0.72

0.48

0.85

Unfaced

0.43

0.49

0.80

0.86

0.67

0.56

0.70

Encapsulated

0.38

0.42

0.79

0.79

0.48

0.41

0.60

Unfaced

0.58

0.53

0.98

0.85

0.66

0.52

0.75

Encapsulated

0.60

0.79

0.66

0.50

0.46

0.46

0.60

Unfaced

0.40

0.75

0.83

0.68

0.70

0.54

0.75

Encapsulated

0.58

0.91

0.93

0.68

0.59

0.46

0.80

Unfaced

0.40

0.89

0.85

0.72

0.70

0.53

0.80

Encapsulated

0.53

0.88

0.82

0.70

0.63

0.52

0.75

Unfaced

0.78

0.99

0.86

0.79

0.72

0.52

0.85

Encapsulated

0.84

0.93

0.79

0.75

0.65

0.93

0.80

3W PANELS

Batt

GENERAL INFORMATION

Acustadek 8.2

BHF-36A

2W PANELS

NHF-32A

B PANELS

2WHF-36A

3WHF-36A

N PANELS

4.5DF-24A

C PANELS

6DF-24A

D PANEL

7.5DF-24A

www.ascsd.com

Composite and Non-Composite Deck Catalog May 2014

ACUSTADEK

Table Notes:
1. Noise reduction coefficient testing was conducted in accordance with ASTM C423 and ASTM E795.
2. Unfaced or encapsulated fiberglass batts wrapped with clear plastic film.

179

TABLE OF CONTENTS

Metric Conversion Chart

Metric Conversions

Spans, length & thickness

Multiply

By

To Obtain

Inches

25.4

Millimeters

Feet

304.8

Millimeters

Inches

0.0254

Metres

Feet

0.3048

Metres

psf

0.0479

kPa

psi

6.8948

kPa

Square feet

0.0929

Square Metre

Square

9.2903

Square Metre

Diaphragm Shear

plf

0.0146

KN/m

Section Properties

in3/ft

53,763

mm3/m

in /ft

1,365,588

mm4/m

in3/ft

53.763

cm3/m

in4/ft

136.559

cm4/m

Pounds

0.00445

kN

psf

4.8824

kg/m2

pcf

16.018

kg/m3

Vertical Load & Superimposed Load


Area

Weight
Volume

180

Composite and Non-Composite Deck Catalog May 2014

www.ascsd.com

TABLE OF CONTENTS

Evolution of Company
ASC Steel Deck has provided structural steel roof and floor
deck all through the Western United States since the 1970s.
Throughout the years, ASC Steel Deck has undergone a few
ownership changes and operated under different business
names (ASC Pacific, BHP Steel Building Products, and IMSA
Building Products). Since 2002, however, we have operated
under the name ASC Steel Deck, a division of ASC Profiles
LLC. While the name of the company has changed over
the years, the continuous dedication to product innovation,
high quality steel deck products, and customer service has
positioned ASC Steel Deck as a leader in the industry.

Industry Innovator
With an outward focus on the steel deck industry, ASC Steel Deck has led the way and established itself as a leader having
accomplished many industry-firsts. ASC Steel Deck was the first West Coast manufacturer to incorporate superimposed
load tables based on ANSI/SDI C-2011 Standard for Composite Steel Floor Deck-Slabs. This standard has been adopted for
inclusion in the forthcoming 2015 IBC. Moreover, ASC Steel Deck was the first on the West Coast to adopt the SDI C-2011
Standard for Composite Steel Floor Deck-Slabs.
ASC Steel Deck has also led the way in providing innovative products that reduce installation costs, while offering some of the
highest diaphragm shear values in the market. For example:
36/7/4 Attachment Pattern - reduces attachment requirements for 112" roof deck by up to 30%.
N-32 Roof Deck - an entirely new 3" deep roof deck profile providing a 10% improvement in steel utilization and up to
20% reduction in installation costs as compared to the industry standard N-24 panel.
Whether through product re-engineering or new product development, ASC Steel Deck strives for constant improvement
through innovation.

TABLE OF CONTENTS

Manufacturing Facilities

ASCSteel Deck Sacramento, CA


2110 Enterprise Boulevard
West Sacramento, CA 95691
916-372-6851
800-726-2727
ASCSteel Deck Fontana, CA
8432 Almeria Avenue
Fontana, CA 92335
Visit us at:
www.ascsd.com

2014 ASC Profiles LLC All trademarks are the property of their respective owners. All rights reserved. June 2014 (DL021)

You might also like