Professional Documents
Culture Documents
Overview - Channels
Upper Layers
DL
UL
RLC
DCCH
DTCH
CCCH
MTCH
MCCH
DTCH
DCCH
CCCH
PCCH
BCCH
Logical channels
MAC
UL-SCH
RACH
MCH
DL-SCH
PCH
BCH
Transport channels
PHY
PUSCH
PUCCH
PRACH
PMCH
PDCCH
PCFICH
PHICH
PDSCH
PBCH
Air interface
eNode B
DL control
configuration
1x per cell
RNTI
DL scheduling
UL Grant
UL PWRC
n x per cell
HARQ Info
Resource Block
Physical Resource Block or Resource Block (PRB or RB):
12 subcarriers in frequency domain (180kHz) x 1 slot period in time domain
(0.5ms)
Capacity allocation is based on Resource
Subcarrier 1 0 1 2 3 4 5 6 0 1 2 3 4 5 6
Blocks
0 1 2 3 4 5 6 0 1 2 3 4 5 6
0 1 2 3 4 5 6 0 1 2 3 4 5 6
180 KHz
0 1 2 3 4 5 6 0 1 2 3 4 5 6
0 1 2 3 4 5 6 0 1 2 3 4 5 6
0 1 2 3 4 5 6 0 1 2 3 4 5 6
0 1 2 3 4 5 6 0 1 2 3 4 5 6
0 1 2 3 4 5 6 0 1 2 3 4 5 6
0 1 2 3 4 5 6 0 1 2 3 4 5 6
0 1 2 3 4 5 6 0 1 2 3 4 5 6
0 1 2 3 4 5 6 0 1 2 3 4 5 6
Subcarrier 12 0 1 2 3 4 5 6 0 1 2 3 4 5 6
1 slot
1 slot
1 ms subframe
For internal use
8
Nokia Siemens Networks
Resource
Element
Frequency
symbols
subcarriers
subcarriers
Antenna 1
For internal use
10
Nokia Siemens Networks
Antenna 2
168 Cell ID
groups
Cell ID Group i
(3 L1 ids)
Primary
Synchronization Signal
Secondary
Synchronisation Signal
Group 167
Phy L Cell ID
Physical Layer
Cell ID, Frame
Alignment
For internal use
12
Nokia Siemens Networks
PDCCH:
Occupies the REs not used by PCFICH and PHICH
and Reference Signals within the first 1, 2 or 3
symbols of each TTI (case 1.4 MHz: within the first 2,
3 or 4 symbols)
In RL09/10: configuration static by
MaxNbrOfOFDMSymsForPDCCH
PDSCH:
Is allocated the RE not used by signals or other
physical channels
For internal use
13
Nokia Siemens Networks
RB
UL Physical Channels
PUSCH: Physical Uplink Shared Channel
Intended for user data (carries traffic for multiple
UEs) and control data
If control data is to be sent when traffic data is being
transmitted, UE multiplexes both streams together
CCCH
DCCH
DTCH
Logical
RLC
Transport
RACH
UL-SCH
MAC
PHYS.
PRACH
PUSCH
PUCCH
UL Channels
The mapping of transport channels and UL control information (UCI) to physical
channels is a task of the physical layer (PHY). Furthermore reference signals are
provided by the physical layer which do not transfer any higher layer information.
Logical channel mapping is provided by the MAC layer.
Physical channel for data and signalling from higher layers:
Physical Uplink Shared Channel, PUSCH.
Physical Random Access Channel, PRACH.
Physical channels with UL control - related signalling:
Physical Uplink Control Channel, PUCCH.
and signals with no information of higher layers:
Demodulation Reference Signals (DRS).
Sounding Reference Signal (SRS).
(1) eNodeB
transmission
(3) UE
feedback