Diesel
Generator set
QSK50 series
engine
1125 kVA-1700 kVA 50 Hz
Description
Permanent magnet generator (PMG) - Offers
enhanced motor starting and fault clearing shortcircuit capability.
Features
Cummins heavy-duty engine - Rugged 4cycle, industrial diesel delivers reliable power,
low emissions and fast response to load
changes.
Alternator - Several alternator sizes offer
selectable motor starting capability with low
reactance 2/3 pitch windings, low waveform
distortion with non-linear loads and fault
clearing short-circuit capability.
Standby rating
Prime rating
Continuous rating
Data sheets
50 Hz
kVA (kW)
50 Hz
kVA (kW)
50 Hz
kVA (kW)
50 Hz
DQGAK
1540 (1232)
1400 (1120)
1125 (900)
D-3520
DQGAJ
1700 (1360)
1540 (1232)
1250 (1000)
D-3522
Model
cumminspower.com
2012 Cummins Power Generation Inc. | S-1646 (6/12)
Engine specifications
Bore
Stroke
Displacement
Configuration
Battery capacity
Battery charging alternator
Starting voltage
Fuel system
Fuel filter
Air cleaner type
Lube oil filter type(s)
Standard cooling system
Alternator specifications
Design
Stator
Rotor
Insulation system
Standard temperature rise
Exciter type
Phase rotation
Alternator cooling
AC waveform total harmonic distortion
Telephone influence factor (TIF)
Telephone harmonic factor (THF)
Available voltages
60 Hz line-neutral/line-line
50 Hz line-neutral/line-line
220/380
230/400
1905/3300
3637/6300
240/415
3810/6600
254/440
6350/11000
Control panel
PowerCommand 3.3
Multiple language support
120/240 V 100 W control anticondensation heater
Exhaust pyrometer
Ground fault indication
Remote annunciator panel
Paralleling relay package
Shutdown alarm relay package
Audible engine shutdown alarm
AC output analog meters
(bargraph
Exhaust system
Industrial grade exhaust
silencer
Residential grade exhaust
silencer
Critical grade exhaust silencer
Exhaust packages
Cooling system
Remote cooling
Enhanced high ambient
temperature (50 C)
Generator set
Battery
Battery charger
Bottom entry chute
Circuit breaker skid mounted up
to 3000 Amp
Circuit breaker auxiliary and trip
contacts
IBC and OSHPD seismic
certification
In-skid AVM
LV and MV entrance box
Manual language English, French
and Spanish
Spring isolators
2 year warranty
5 year warranty
10 year major components warranty
Note: Some options may not be available on all models - consult factory for availability.
cumminspower.com
2012 Cummins Power Generation Inc. | S-1646 (6/12)
Operator/display functions
Displays paralleling breaker status
Provides direct control of the paralleling breaker
320 x 240 pixels graphic LED backlight LCD
Auto, manual, start, stop, fault reset and lamp test/panel lamp
switches
Alpha-numeric display with pushbuttons
LED lamps indicating genset running, remote start, not in
auto, common shutdown, common warning, manual run
mode, auto mode and stop
Paralleling control functions
First Start Sensor System selects first genset to close to bus
Phase Lock Loop Synchronizer with voltage matching
Sync check relay
Isochronous kW and kVar load sharing
Load govern control for utility paralleling
Extended Paralleling (baseload/peak shave) Mode
Digital power transfer control, for use with a breaker pair to
provide open transition, closed transition, ramping closed
transition, peaking and base load functions.
Alternator data
Line-to-neutral and line-to-line AC volts
3-phase AC current
Frequency
kW, kvar, power factor kVA (three phase and total)
Engine data
DC voltage
Engine speed
Lube oil pressure and temperature
Coolant temperature
Comprehensive FAE data (where applicable)
Other data
Genset model data
Start attempts, starts, running hours, kW hours
Load profile (operating hours at % load in 5% increments)
Fault history
Data logging and fault simulation (requires InPower)
cumminspower.com
2012 Cummins Power Generation Inc. | S-1646 (6/12)
Ratings definitions
Emergency standby power (ESP):
Applicable for supplying power to varying electrical
loads for the duration of power interruption of a reliable
utility source. Emergency Standby Power (ESP) is in
accordance with ISO 8528. Fuel Stop power in
accordance with ISO 3046, AS 2789, DIN 6271 and BS
5514.
Limited-time running power (LTP):
Applicable for supplying power to a constant electrical
load for limited hours. Limited Time Running Power
(LTP) is in accordance with ISO 8528.
Prime power (PRP):
Applicable for supplying power to varying electrical
loads for unlimited hours. Prime Power (PRP) is in
accordance with ISO 8528. Ten percent overload
capability is available in accordance with ISO 3046, AS
2789, DIN 6271 and BS 5514.
Base load (continuous) power (COP):
Applicable for supplying power continuously to a
constant electrical load for unlimited hours. Continuous
Power (COP) in accordance with ISO 8528, ISO 3046,
AS 2789, DIN 6271 and BS 5514.
No sustained overload capability is available at this rating.
Dim A
Dim B
Dim C
Set Weight*
Model
mm (in.)
mm (in.)
mm (in.)
dry kg (lbs)
DQGAK
6381 (251)
2285 (90)
2474 (97)
11293 (24897)
DQGAJ
6381 (251)
2285 (90)
2474 (97)
11551 (25465)
* Weights represent a set with standard features. See outline drawings for weights of other configurations.
Set Weight*
wet kg (lbs)
11926 (26292)
12184 (26861)
2000/14/EC
ISO8528
Warning: Back feed to a utility system can cause electrocution and/or property damage. Do not connect to any buildings electrical system
except through an approved device or after building main switch is open.
North America
1400 73rd Avenue N.E.
Minneapolis, MN 55432
USA
Phone 763 574 5000
Fax 763 574 5298
cumminspower.com