Project Planning Evolution compact.


Traction Drive Elevator
without Machine Room and Shaft Pit.
Rated Load 6301050 kg.

A Company
of ThyssenKrupp
Elevator

ThyssenKrupp Aufzge

tk

SP

SD

Evolution compact without Machine Room


and Shaft Pit Higher, Faster, Less.
Facts, Data and Dimensions.

Evolution compact, the traction


driven standard passenger
elevator without machine room
and shaft pit, has been
designed for more powerful,
but also economical passenger
service in cases with little
ground clearance (e.g. above
underground carparks, supply
lines and groundwater).
A number of revolutionary innovations concerning the elevator
car and various safety devices
have enabled us to replace the
shaft pit with a reduced shaft pit
depth of only 300 mm.
The Thyssen Mini gearless, a
frequency-controlled, gearless
high-performance drive, moves
standardized elevator cars with
rated loads of 630 or 1000 kg
resp. 675 or 1050 kg with open
through at a speed of 1.0 m/s.

Abbreviations:
A
= right-hand door soffit
CD = car depth
CW = car width
DH = door height
DW = door width
FF = finished floor
O1 = hoisting ring above machine
frame
O2 = hoisting ring(s) above door(s)
Q
= rated load
R
= recess
SD = shaft depth
SH = shaft head
SP = shaft pit
SW = shaft width
UF = unfinished floor
v
= speed

Dimensions
The dimensions indicated are finished
measures if not stated expressly.

Q
[kg]/ open
[pass.] through

door
type

no

central

800

telescopic 900

yes

central

800

1800

1855

20

1780

1795

55

1930

2040

20

1890

1920

900
telescopic 900

1000/
13

no

central

800

55

2500

2555

20

2480

2495

900
telescopic 900

1050/
14

yes

central

800
900

55

900
675/
9

plastering and thus easily be


made to fit the wall plastering of
the building. However, you can
also use wall frames in the case
of altered dimensions. You will
find more details in our project
planning document Door
openings.
Please find information on the
overall design of elevator installations in our separate planning
information.
Should your requirements or
demands exceed the following
range, please contact one of
our experienced consultants.

door recess
with
without
DW
R
SD
SD
SW
A
CD
[mm] [mm] [mm] [mm] [mm] [mm] [mm]

telescopic 900

630/
8

The standard equipment of


our elevator installations implies
the efficient, proven and
convenient S8/K8 doors as twopart telescopic sliding doors in
left-hand execution. However,
they are also available in righthand execution or as central
opening execution. The telescopic
doors are 900 mm in width,
the central opening doors are
available in widths of 800 and
900 mm. And to complete the
range, you can select between
the installation of the landing
doors on the landing in a recess
or entirely in the shaft.
The following shaft ground
plans and vertical sections show
the door openings with gaps
between the wall soffit or lintel
and door frame which can be
filled by means of concreting or

55

2630

2740

20

2590

2620

1650

100

1850

425

2000

450

1650

100

1850

425

2000

450

1650

100

1850

425

2000

450

1650

100

1850

425

2000

450

meas.
in acc.
CW with DIN
[mm] 18024/25

1400

1100

1400

1100

2100

1100

2100

1100

Evolution compact without Machine Room


and Shaft Pit A Cut Above.
Shaft Ground Plans.

With open through

675 kg / 9 passengers

1050 kg / 14 passengers

SW

SW

DW + 200

DW + 200

DW

DW

SD

SD

With central opening sliding doors:

SW

SW

DW + 200

DW + 200

DW

DW

SD

SD

With telescopic sliding doors:

630 kg / 8 passengers

1000 kg / 13 passengers

CW = 1100

CD

SD

SD

CD

CW = 1100

DW

SW

DW + 200
DW
DW + 200

SD
R

With central opening sliding doors:

SD

SW

DW

DW

DW + 200

DW + 200

SW

SW

Evolution compact without Machine Room


and Shaft Pit A Cut Above.
Constructional Ground Plans and Shaft Head Plans.
Occurring Forces.

Occurring forces [kN]

Q [kg]

630 / 675

1000 / 1050

P1

Shaft head recess (machine frame)

P2

Shaft head recess (machine frame)

10

16

P3

Shaft head recess (machine frame)

18

27

P4

Shaft head recess (machine frame)

10

11

O1

Shaft ceiling (hoisting ring for machine)

10

10

O2

Shaft ceiling (hoisting ring for doors)

10

10

UF

UF

 Fill after installation.


(by customer)

Occurring forces [kN]

Q [kg]

630 / 675

1000 / 1050

P7

Shaft pit floor (guide rails)

18

25

P8

Shaft pit floor (car buffer)

73

102

P9

Shaft pit floor (counterweight buffer)

57

78

P10 Shaft pit floor (counterweight guide rails)

29

39

The forces P7P10 never occur simultaneously!

Operating box.
Only in top landing.

SP max. = 400

SP min. = 300

Travel height (TH) min. = DH + 450

Travel height (TH) max. = 40 m (v = 1.0 m/s)

Shaft head (SH) min. = 3550/3650 (v = 1.0 m/s)


Car height (CH) = 2200/2300
DH + 100
Door height (DH) = 2000/2100

Evolution compact without Machine Room


and Shaft Pit Rising to the Top.
Vertical Section.

FF
UF

FF

UF

Recess up to SP floor!

UF

SD

For additional information as well as planning and project data please see
Planning information:
Passenger- and freight elevators (9700 000 1530)
Passenger elevators without machine room (9700 000 1531)
Project planning documents:
Passenger elevators without machine room, arranged in groups (9700 000 1533)
Comfort door S8/K8 planning information and project planning data (9700 000 1529)
Door openings comfort door S8/K8 (9700 000 1534)
Evolution classic traction drive elevator without machine room (9700 000 1537)
Evolution flexible M traction drive elevator without machine room with variable car dimensions,
rated load 6301050 (9700 000 1539)
Evolution flexible L traction drive elevator without machine room with variable car dimensions,
rated load 10001650 (9700 000 1540)

FF
UF

ThyssenKrupp Aufzugswerke GmbH


A Company of ThyssenKrupp Elevator
P.O. Box 23 03 70, 70623 Stuttgart, Germany
Tel.: +49 (0) 7158 12 - 0, Fax: +49 (0) 7158 12 - 2585
E-mail: info@tke-aufzuege-de.thyssenkrupp.com
Internet: www.thyssen-aufzuege.com

Printed in Germany 9700 000 1538-1 01/03