Professional Documents
Culture Documents
PROCEDURE FOR
INSTALLATION OF THE GOVERNOR
SN POWER
CHEVES HEPP
PELTON TURBINE
Unit 1 and 2
0
Rev
2013-03-15
Date
E. Larsen
Written by
Dept
J. Jensen
Appr
Document
PROCEDURE
Document no.: ARA000273-O1N
SN POWER
KH doc. no.:
Revision No.:
Page
0
2 of 11
Subject:
2013-03-15
This document and the design is the property of Rainpower and must not be used nor disclosed to any third party without Rainpower
permission.
Order no.
Index
221304
R010
Activity
Code
Customer
SN Power
Site
File Name
CONTENT
1
PURPOSE ........................................................................................................ 3
DEFINITIONS ................................................................................................. 3
DESCRIPTION ............................................................................................... 5
4.1
4.2
REFERENCES ................................................................................................ 6
5.1
Drawings............................................................................................................ 7
5.2
DEVIATIONS .................................................................................................. 7
ENCLOSURES ................................................................................................ 7
Document
PROCEDURE
Document no.: ARA000273-O1N
SN POWER
KH doc. no.:
Revision No.:
Page
0
3 of 11
Subject:
2013-03-15
This document and the design is the property of Rainpower and must not be used nor disclosed to any third party without Rainpower
permission.
PURPOSE
The procedure describes the installation steps for the Pelton turbine governors
supplied by Rainpower AS, hereafter named RP, for SN Power - Cheves HEPP
turbine 1 and 2, hereafter named SNP.
The procedure is designed to ensure that the installation will be performed in
accordance with Contractual requirements and to a high standard of
workmanship. Sketches and diagrams are included to support the installation
sequences described herein.
The procedure is made for the 1st unit, and may be revised for the next unit if
changes are regarded as favourable for the progress of work.
DEFINITIONS
Site Installation Control Form (SICF) forms to verify and record
performance of the installation steps. Tolerances, as built dimensions from
drawings and measured dimensions at site are included in the forms as
appropriate. The sheets are designated as Form 1, Form 2, etc.
Control comparison with specified requirements to verify compliance.
Technical information documents that specify detailed requirements.
This may be the Contract, drawings and other relevant information in order to
secure the performance of the installation work.
Inspection Plan (TP) document describing the various inspections to be
performed during site installation with reference to the Installation Procedure
and applicable SICF.
Document
PROCEDURE
Document no.: ARA000273-O1N
SN POWER
KH doc. no.:
Revision No.:
Page
0
4 of 11
Subject:
2013-03-15
This document and the design is the property of Rainpower and must not be used nor disclosed to any third party without Rainpower
permission.
Document
PROCEDURE
Document no.: ARA000273-O1N
SN POWER
KH doc. no.:
Revision No.:
Page
0
5 of 11
Subject:
2013-03-15
This document and the design is the property of Rainpower and must not be used nor disclosed to any third party without Rainpower
permission.
DESCRIPTION
4.1
Instruction manual
The sequences of the installation work are given in the Instruction Manual that
is included in the procedure refer section 8.
The Instruction Manual expresses the specific steps of work for installation of
the equipment, and provides reference to relevant documents and SICF as
appropriate.
The Instruction Manual includes columns for:
The actual item and activity number
The specific activity to be carried out with number
The company responsible for the activity
Detailed description of the activity
Sketches and references to relevant drawings, documents and SICF
To avoid confusion or conflicts, no design values or tolerances that are
stated on the drawings are repeated in the manual, however nominal
values and tolerances may be included in the SICF
Document
PROCEDURE
Document no.: ARA000273-O1N
SN POWER
KH doc. no.:
Revision No.:
Page
0
6 of 11
Subject:
2013-03-15
This document and the design is the property of Rainpower and must not be used nor disclosed to any third party without Rainpower
permission.
4.2
Rotating equipment/machinery
Electrical hazards
Flood/drowning hazards
Pressurized substances (oil, nitrogen, air, water)
Fire (cable/electrical fire, oil fire)
Noise
Overhead/lifting hazards
For safety purposes SNP should check, test or certify, as appropriate, all
handling and lifting equipment to be used during the installation work.
This equipment is supposed to be permanent equipment installed at site.
IC shall present valid certificates for handling of lifting tools for SNP and RP.
REFERENCES
Contract between SN Power and the Consortium Rainpower AS, Jeumont and
ABB.
General requirements for welded constructions, RP doc. No. 30103.
Procedure for flushing of oil pipes to governor and main inlet valve MIV
RP doc. 24993
Document
PROCEDURE
Document no.: ARA000273-O1N
SN POWER
KH doc. no.:
Revision No.:
Page
0
7 of 11
Subject:
2013-03-15
This document and the design is the property of Rainpower and must not be used nor disclosed to any third party without Rainpower
permission.
5.1
Drawings
INDEX
R670
R510
R010
5.2
TITLE
Mech./Hydraulic Over Speed Device
Piping Arrangement
Hydraulic diagram
DRAWING NUMBER
RP-D-N-I-P-014
RP-D-N-I-P-001
RP-D-N-I-P-013
Form No
Cable check
DEVIATIONS
None.
ENCLOSURES
None.
8
1
Resp
JOB STEPS
INSTRUCTION MANUAL
INSTALLATION OF THE
GOVERNOR
OIL PRESSURE
UNIT (OPS)
WITH
ACCUMULA_
TOR
1-1
Preconditions
SNP/
CW
SNP/
CW
RP/
SNP
1-2
General
IC/RP
2-1
Preparations
RP/IC/
CW
2-2
Installation
REFERENCE
Resp
OVERSPEED
DEVICE
PIPING
JOB STEPS
3-1
Preparations
RP/IC
3-2
Installation
IC/RP
4-1
Preparations
RP/IC
4-2
Installation
RP/IC
4-3
Cleaning
RP/IC
4-4
Bullet cleaning
RP/IC
4-5
Flushing
RP/IC
REFERENCE
OIL TANK
Pressure testing
Resp
RP/IC
JOB STEPS
5-1
Cleaning
RP/IC
5-2
Oil type
RP/IC
5-3
Oil filling
RP/IC
ELECTRONIC
6-1
AND CONTROL
CUBICLES
Installation
RP/IC
CABLING
Installation and
test
RP/IC
7-1
REFERENCE
Rev.
ARA000273PRI
Side / Page
av / of
Kunde / Customer
400409
SN Power
RP-Q-N-I-P-001
Indeks / Index
Anlegg / Site
R010
Cheves
ARA000273-PRI
Rainpower and Rainpowers customer shall be able to inspect all stages in the process at
supplier and sub-suppliers. These inspections might happen any time at any location.
All NDT shall be reported, also indications that has been repaired.
05.01.12
First Issue
TFa
Rev.
Dato / Date
Beskrivelse / Description
Sign.
Avd. / Dept.
Godkj. / Appr.
10
Index
Production
stage
Inspection
Procedure
Location
Responsible
Witness
Report
form
RC Remarks
R010
Governor
Assembled
FINAL
Commissioning
procedure
SITE
RP
CLIENT
PROT
Drytest on
site.
R490
GOPS 600
Hydraulic
controls
Assembled
VI
FUNCT
FAT Report
PRESSURE
SUPL
RP
CLIENT
PROT
Assembled
test.
FAT
R450
Accumulators
Assembled
VI
FUNCT
FAT Report
PRESSURE
SUPL
RP
CLIENT
PROT
Assembled
test.
FAT
R620
Electronic
governor HY14P
Assembled
VI
FUNCT
Assembled
test
FAT
R670
Overspeed trip
device
Assembled
VI
FUNCT
Calibrated
before test at
site.
FAT Report
FAT Report
SUPL
SUPL
RP
RP
CLIENT
CLIENT
PROT
PROT
11
INDEX
Numbering of inspection activity and/or item designation according to Rainpower project index list.
2
The name of the part or the parts. Drawing and item number has to be specified when it is suitable to
identify the part or parts
3
PRODUCTION STAGE
INSPECTION
Chemical analysis
MAT
Material test
TT
Tensile testing
CIT
HT
Heat treatment
BT
Bend test
CR
Contract review
PQR
WPS
Welding procedure
WELDER
Qualification of welders
NDT-OP
CALC
RESSTR
DRAW
PURCH
RECEIPT
Receiving inspection
CERT
Certificate check
VI
Visual inspection
NDT
ACCEPT
Acceptance criteria
UT
Ultrasonic testing
3 of 5
RT
Radiographic testing
MT
PT
Penetrant testing
HB
Hardness test
DT
BAL
Balancing
PRESSURE
Pressure testing
LEAKAGE
Tightness inspection
FUNCT
Function testing
FINAL
Final testing
PROCEDURE
LOCATION
Machine shop
SFS
SUPPL
Supplier's workshop
SITE
Erection site
STOCK
Warehouse department
RESPONSIBILITY
The letter designation, possible group number for the organization unit, who is responsible for the
inspection or test performance.
SUPPL
Suppliers workshop
RP
Rainpower
BUYER
The customer
WITNESSING
Representation, if any, by a party other than he who performs the inspection test.
Internal party is given by the letter designation, external as follows:
RP
Rainpower
CONS
CLIENT
_____
Hold point, i.e. the process must not proceed until passed by the witness
as indicated by underlining.
9
REPORT FORM
PROT
Inspection record
10
REPORT TO BUYER
Indeks/Index
Kunde/Customer
R010/K010
SN Power
Form 1
Byggested/Fab. site
Sak/subject
Side /Page
Cheves HEPP
Uni 1 and 2
Pos. nr /Part No
Del / Part
221304
1
Dato / Date
Unit No.
CLEANING
RESULT
RESULT
CLEANLINESS TEMPERATURE
LEVEL
Servo 1
Servo 2
Other pipe lines (to be determined at site)
Other pipe lines (to be determined at site)
Acceptance criteria:
Cleanliness level
6 m/s
Performed
01_Form 1 _ Cleaning pipes
300 l/min
Witnessed
Approved
Approved
av / of
1
Sign
Indeks/Index
Kunde/Customer
R010/K010
SN Power
Form 2
Byggested/Fab. site
Sak/subject
Side /Page
Cheves HEPP
Unit 1 and 2
Pos. nr /Part No
Del / Part
221304
1
Dato / Date
Unit No.
PIPE LINE
PRESSURE (bar)
Acceptance criteria:
Test pressure
bar
Holding time
min
Medium
Performed
02_Form 2 _ Pressure test pipes
Water
Witnessed
Approved
Approved
av / of
1
Sign
Indeks/Index
Kunde/Customer
SN Power
Form 3
Byggested/Fab. site
Sak/subject
Side /Page
Cheves HEPP
Unit 1 and 2
Pos. nr /Part No
Del / Part
Survey of cabling
221304
K500
1
Dato / Date
Unit No.
Survey of cabling
WIRING DIAGRAM
RESULT
Performed
03_Form 3 _ Survey of cabling
Witnessed
Approved
Approved
av / of
1
Sign