You are on page 1of 5

187

( Logging of True RMS digital multimeter with


Accuracy: +-0.05% 187)

Features
l

Measurements: AC voltage,
DC voltage, AC current ,DC
current, OHM,
Frequency, Period, Pulse
width,Capacitance, Beep, Diode,
dBm, Thermocouple (TC),
Thermal resistance (RTD),
AC+ DC, AC +
Hz measurement, Maximum,
Minimum, Average
measurement (MAX / MIN /
AVG), The relative value
measurement (REL_%)
l
Measurements show that 55,000 words, the basic accuracy 0.02% (VICTOR 189) / 0.05%
(VICTOR 187)
l
Three measurement rate: FAST, SLOW, SMOOTH, the fastest refresh rate of simulation
bar: 14 / sec
l
Manual range or automatic range selection

Specifications:
Measurements

Range

Measuring
range

Resolution

DCV

5.0000V

0.0001V

50.000V

0.001V

Input impedance
10M

500.00V

0.01V

1000.0V

0.1V

50.000mV

0.001mV

500.00mV

0.01mV

DCmV

2200.0mV

www.ttbvision.com

0.1mV

Input impedance
approx. 100M

ACV

ACmV

OHM

DCA

DCmA

DCuA

ACmA

ACuA

www.ttbvision.com

5.0000V

0.0001V

50.000V

0.001V

500.00V

0.01V

760.0V

0.1V

50.000mV

0.001mV

500.00mV

0.01mV

500.00

0.01

5.0000K

0.0001K

50.000K

0.001K

500.00K

0.01K

5.0000M

0.0001 M

50.000M

0.001 M

500.0M

0.1 M

5.0000A

0.0001 A

20.000A

0.001 A

50.000mA

0.001mA

500.00mA

0.01 mA

500.00uA

0.01 uA

5000.0uA

0.1 uA

5.0000A

0.0001 A

50.000mA

0.001mA

500.00mA

0.01 mA

500.00uA

0.01uA

50000uA

0.1uA

Input
impedance
10M /
50pF

Input
impedance
1M / 50pF

CF3
187
20Hz
30kHz
10
110%
Range)
189
20Hz
100kHz
5
110%
Range)

Open circuit voltage


2.5V

Voltage Drop 0.04


V/A

Voltage Drop
1.8 mV/mA

Voltage Drop
103uV/uA

FREQ

9.9999Hz

0.0001Hz

99.999Hz

0.001Hz

999.99Hz

0.01Hz

9.9999KHz

0.0001KHz

99.999KHz

0.001KHz

999.99KHz
0.01KHz
9.9999MHz
99.999MHz

0.0001MHz

0.001MHz

DUTY

0.1%99.9%

0.1%

0.5Hz1KHz
Square Wave

199.99ms

0.01ms

1999.9ms

0.1ms

DIODE

2.2000V

0.0001V

Open circuit voltage


<3.5V
Short circuit0.8mA

CHCNT

500.0

0.1

Open circuit voltage


<3.5V
Short circuit<0.8mA
Short alarmapprox.
<20
Open alarmapprox.
>120

CAP

9.999nF

0.001nF

99.99nF

0.01nF

999.9nF

0.1nF

9.999F

0.001uF

99.99F

0.01uF

999.9F

0.1uF

9.999mF

0.001mF

99.99mF

0.01mF

PULSE

TC

www.ttbvision.com

-40C
1760C

1C

ITS-90

RTD

-40C
1760C

-270.0
1370.0

0.1C

-270.0
720.0

0.1C

-210.0
850.0

0.1C

-270.0
400.0

0.1C

-270.0
1300.0

0.1C

4001800

1C

Pt100

-200.0
850.0

0.1C

Pt1000

-200.0
630.0

0.1C

Pt100-385

Other Features:
l

DC Voltage measurement
CMRR50Hz / 60Hz 120dB
SMRR50Hz / 60HzRs=1k 80dB
AC Voltage measurement
CMRR50Hz / 60HzRs=1k 80 dB
A residual reading with input shorted, will not affect stated accuracy above 5 % of range.
OHM measurement
For relative humidity greater than 70 %, resistance accuracy is 0.5 % over 1 Mand 2.5 %
over 10 M.
Internal temperature compensation sensor RJC:
temperature range: -10 ~ 50, compensation error 0.5 , compensation time for 10
seconds each time
Maximum voltage between any Terminal and Earth Ground :
1000V DC / AC rms
Fuse protection for mA input: 500 mA / 250V FAST fuse
fuse protection for 20A input: 20 A / 250V FAST fuse
Can be as high as 20 A continuous measurement of the current, if the signal detected in 10
A ~ 20 A of maintaining maximum of 30 seconds, then specified the need to increase the
accuracy of 0.5%
Real-Time Clock
1min / 1month
Temp. Influence 50 ppm per C

www.ttbvision.com

Measured rate
Functional range

Measuring rate
FAST

SLO
W

SMOOTH

DC voltage and current

14

AC voltage and current

14

1.8

1.8

Resistors, diodes, on-off

General Specifications:
l
Operating Temperature and Humidity
0 to 50oC,(no condensation 10oC) 85%RH
l
Storage Temperature and Relative Humidity
-20oC to 60oC90%RH
l
Altitude
2000m max. above sea level
l
Rated transient over-voltage
6KV1.2*50usCAT, CAI , CAT peak measurement
l
Vibration and Shock
Random 2g, 5 to 500Hz
1 meter drop test
l
Period of calibration and warm-up time
Accuracy is specified for a period of one year after calibration or other
Warm-up time is 10 minutes or other
l
Display and LED
* LCD36.368.0mm
* white LEDable to set time 09999S
l
Supply
* 4 x 1.5V Alkaline batteries supply
* 4 x 1.2V Ni-Hi batteries supply
* Auto Power-offable to set time 09999minutes
l
Safety Standards
IEC 61010-1, 2000
Overvoltage category III (Max. input voltage:AC/DC600V)
Overvoltage category II (Max. input voltage:AC/DC1000V)
Pollution degree 2
l
Weight and Size
205 95 42mm approximate 500g

www.ttbvision.com