2013 1st Edition

Rigid PVC Pipe and Fittings with anti water condensation layer for air conditioning drainage

AC DRAIN PIPE
ESLON AC DRAIN Fittings
ESLON Transparent AC DRAIN Fittings
ESLON AC DRAIN Flexible Unit
ESLON

NEW
NEW

l
a
i
r
e
t
a
pi i n g m

p
e
l
b
a
t
i
u
s
t
s
Mo
for
e
g
a
n
i
a
r
d
g
n
i
n
o
i
t
i
d
n
o
air c

Most suitable piping material for air conditioning drainage is


Eslon AC Drain Pipe and Fittings prevent water condensation and do not require any insulation work.
It is a perfect fit for air conditioning drainage in office, hotel and hospital, etc.

Problems

Eslon AC Drain Pipe & Fittings solve all problems!

on conventional air conditioning drainage.

Secure the installation

Insulation work

It is a time consuming
for insulation work.

Threading work

Cannot check joint


and slope angle.

Threading is painful work.

o not need insulation work

Eslon AC Drainage Pipe and Fittings have a function of thermal insulation. Therefore you do not need any insulation work.

with
AC Drain

Conventional
Multiple operations were required.
Method
In case of Packaging Air Conditioning

Insulation Work

Drainage Work

Refrigerant,
Drainage,
Insulation Work,

In case of Fan Coil Unit

Refrigerant
Arrangement

Multiple works can be eliminated.


AC Drains is effective to reduce installation time.

Cold and Hot Water


Drainage Work

Insulation Work

Cold and Hot Water,


Drainage and
Insulation Work,

asy to Install and Improve the Quality

Installation is identical to a conventional DV connection. There is no outer insulation material. Therefore, inspection work on joint and
slope setting is much easy. In addition, visual inspection and securing the joint works are feasible by using Transparent Fittings.

ost Saving
Installation Cost Comparison (assume 2 sets of fan coil unit)

Eslon AC Drain Pipe and Fittings System is economical because


of easy installation and elimination of insulation work.

Example of AC Drain Pipe Plumbing [In case plumbing length is 13meter]


5,00

0
50

1,

25

Adapter

25 Elbow

56%

3025 90 Tee

30

25 Socket

500

109%

44%

Installation
Labor
Insulation
Material

86%

Plumbing
Labor

60%

Plumbing
Material

12%
50%

30

13%

AC Drain
(Fitting : Ivory)

0
50

Adapter

34%

34%

3,00

3025 Socket

25

192%

12%
100%
0%

1,00

25 Elbow

AC Drain Pipe plumbing


is set as 100.

1,

500

VP Pipe +
SGP (Steel) +
Insulation Material Insulation Material

The above is based


on publicly announced cost information in Japan.

25 Elbow

AC Drain Pipe and Fittings!


Water condensation is prevented by foamed layer.
Both Pipe and Fittings have a foamed insulation layer. This prevents whole
plumbing from water condensation without having outer insulation material.

Fitting (Injection Molded Foam Products)


Same size with standard socket

Pipe

Feasible to connect pipe


and fittings by adhesive.

ABS Foamed Layer


PVC Surface Layer

PVC Foamed Layer

Provide a good
connection with fitting.

Have superior function in thermal


insulation and prevention of water
condensation.

Increase insulation
property to prevent
moisture
condensation.

Outer Diameter
Identical to VP pipe
which is 1 size larger.
Cross Linked PE Foam
Provide smooth transition
between pipe and fittings for
smooth flow of drainage.

Rigid PVC Layer


Secure flow property for drainage.

Main Body of Fitting(ABS)

Can be applied for air conditioning drainage regardless whether the system is packaged air conditioner or fan coil unit.
Packaged Air Conditioner

Pipe for refrigerant liquid

Fi-Block/Fire Protection
PVC Pipe

AC Drain Pipe

Pipe for refrigerant gas


Drainage Hose, etc.

Eslon AC Drain
Pipe and Fittings
Eslon AC Drain
Flexible Unit

Fi-Block/Fire Protection
PVC Pipe

Packaged Air Conditioner

Fan Coil Unit

Pipe for Hot and Cold Water

Fi-Block/Fire Protection
PVC Pipe

AC Drain Pipe
Drain Hose, etc.

Eslon AC Drain
Pipe and Fittings
Fi-Block/Fire Protection
PVC Pipe

Caution

Fan Coil Unit

Separately heat up or use AC Drain Flexible Unit for pump up section.


May not needed, but please check the condition and determine properly.
AC Drain Flexible Unit
for pump up area.

Applicable Range
Category

Condition

Application

for Air Conditioning Drainage

Water Pressure

Under no pressure (Note)

Water Temperature

Normal Temperature (5-35C)

Nominal Diameter

20-50

Note: Except pump up whose length is less than 1meter


Mark in this brochure
In case left hand mark is stated, it may cause serious

Air Conditioning Unit

AC Drain Pipe

Caution injury or burn wound unless properly treated.

Items with left hand mark is precaution statement to


secure the performance of material

Caution

New
Line Up!!

Transparent
AC Drain Fittings
Structure

Transparent Material(ABS)
Easy to conduct visual check to avoid insufficient
adhesive or insufficient insertion.

ABS Foamed Layer

Main Body
Same size to
DV socket

Cross linked PE foam

Easy to check connecting condition

Refer Page 5, 6, 7
for product line and specification.

Feature
Feasible to check visually about the
adhesive condition between pipe and
fittings with the use of blue adhesive.

Proper
connecting condition

Not inserted
sufficiently

No adhesive
was applied

Use Eslon Adhesive No. 73S Blue or No. 75S Blue N


for the use of transparent AC drain fitting.
Adhesive
No. 73S
Blue

Adhesive
No. 75S
Blue N

Feasible to check connecting condition visually.


Example of plumbing

AC Drain Pipe

Transparent AC Drain Fittings

For pump up section

AC Drain
Flexible Unit

New
Line Up!!

Structure

Protective Tape

Heat insulated flexible pipe

Equipment side elbow


Pipe Socket
AC Drain
25

Extended View
Hose Band

Flexible Hose

Socket for Pipe Connection


Socket for AC Drain

VP25

Easy installation for pump up section

Please refer
to page 7 for specification.

Characteristics
Superior in thermal insulation

Feasible to connect to AC Drain

High thermal insulation property allows not


to use insulation material even in full of water section.
*In case of identical use condition to AC Drain

It has an identical sealing material. Connection


to AC Drain Pipe is feasible.

Heat
insulation

AC Drain Pipe

Prevent
water
condensation

Sealing Material

Socket

Strap support structure

Easy installation by flexible structure

Feasible to conduct proper plumbing by fixing


both fitting and hose.

Thermal insulated flexible pipe is much easy for installation.

Thermal Insulated Flexible Hose

Fix Flexible Pipe


Fix Fitting
*Please use 65A for vinyl SU pipe
to fix fitting, and 32A to fix flexible pipe.

Thermal Insulation is not required.


No insulation work is required for entire pipeline by use
of AC Drain Flexible Unit and AC Drain Pipe & Fittings.

No insulation
work is needed

Lineup of Eslon AC Drain Pipe and Fittings


L

d1

d
d 2

Pipe

t1

Injection Molded Foam Products

ACD20P
ACD25P
ACD30P
ACD40P
ACD50P

20
25
30
40
50

Injection Molded Product

Unit:mm

20
25
30
40
50

t1

t2

d1

d
d 2

d1

t2

d
d 2

Nominal
Diameter

t1

Unit:mm
Outer Thickness Thickness of rigid Approximate Length Reference Weight Quantity
Diameter
PVC layer Inner Diameter
(kg/m)
per package
T
L
(Reference)
D
t
16
0.41
19.0
1.7
6.5
32.0
12
0.50
25.0
2.0
6.5
38.0
9
0.72
31.0
2.0
8.5
48.0
4,000
6
1.00
42.0
2.2
9.0
60.0
4
1.41
57.0
2.5
9.5
76.0

t2

Fittings Socket Dimension (Common)

Part #

Nominal
Diameter

Inner Diameter
d1
d2
31.85
32.25
37.85
38.25
47.80
48.30
59.75
60.35
75.70
76.40

d
19.0
25.0
31.0
42.0
57.0

Length of Pipe Thickness Pipe Thickness


Socket
t1(Minimum) t2(Minimum)
2.7
2.7
2.7
3.1
3.1

8.5
8.5
8.7
9.1
9.4

23
23
27
30
40

<ABS Injection Molded Foam Products>


d1

d
d 2

90Elbow

Unit:mm

t2

10
91

t1

Nominal
Diameter

Effective
Length Z

20
25
30
40
50

23
26
31
37
46

Nominal
Diameter

Effective
Length Z

20
25
30
40
50

14
16
18
22
26

Length Quantity
L
per package
42
45
54
63
82

80
160
100
50
20

Ivory
Part #

Transparent
Part #

ACL20N
ACL25N
ACL30N
ACL40N
ACL50N

ACL20S
ACL25S
ACL30S
ACL40S
ACL50S

Ivory
Part #

Transparent
Part #

AC4L20N
AC4L25N
AC4L30N
AC4L40N
AC4L50N

AC4L20S
AC4L25S
AC4L30S
AC4L40S
AC4L50S

Ivory
Part #

Transparent
Part #

ACT20N
ACT25N
ACT251N
ACT30N
ACT302N
ACT301N
ACT40N
ACT403N
ACT402N
ACT401N
ACT50N
ACT504N
ACT503N
ACT502N
ACT501N

ACT20S
ACT25S
ACT251S
ACT30S
ACT302S
ACT301S
ACT40S
ACT403S
ACT402S
ACT401S
ACT50S
ACT504S
ACT503S
ACT502S
ACT501S

45Elbow

45

Unit:mm
Length Quantity
L
per package
33
35
41
48
62

80
160
100
60
30

90Tee

Unit:mm
Nominal
Diameter

10
91

Z3

L3

20
25
2520
30
3020
3025
40
4020
4025
4030
50
5020
5025
5030
5040

Z1
L1

Z2
L2

Effective Length
Z1 Z2 Z3
23 23 23
26 26 26
23 23 26
31 31 31
23 23 31
26 26 31
38 38 38
23 23 38
26 26 37
31 31 37
46 47 46
23 24 46
26 27 46
31 32 46
38 39 46

Length
Quantity
L1 L2 L3 per package
40
42 42 42
100
45 45 45
40
42 42 45
60
54 54 54
24
46 46 50
60
49 49 50
30
64 64 64
20
49 49 57
40
52 52 56
40
57 57 60
20
82 83 82
20
59 60 65
20
62 63 64
20
67 68 69
20
74 75 72

45Y

Unit:mm
Length
Ivory
Quantity
L2 L3 per package Part #
30
ACY30N
85 89
25
ACY40N
102 108
14
ACY50N
132 138
15
ACY501N
120 118

Transparent
Part #

Length
Quantity
L
per package

Ivory
Part #

Transparent
Part #

ACS20N
ACS25N
ACS251N
ACS30N
ACS301N
ACS40N
ACS401N
ACS50N
ACS501N

ACS20S
ACS25S
ACS251S
ACS30S
ACS301S
ACS40S
ACS401S
ACS50S
ACS501S

Inlet
Length Spigot
Quantity
Ivory
L
side Fitting per package Part #
D
41
20
100 ACDA20
26.0 34 60
TS20
46
25
80 ACDA25
32.0 39 65
TS25
24
30
80 ACDA30
38.0 17 47.5 DV30
29
40
50 ACDA40
48.0 21 55
DV40
32
50
30 ACDA50
60.0 24 64.5 DV50
Remarks: 1. Refer to Page 8 how to apply
2. Connect same nominal diameter of AC Drain for female socket.
Use TS fitting for spigot side in nominal diameter 20, 25 and
DV fitting in nominal diameter of 30, 40 and 50
(TS fitting is not applicable for those diameters).

Transparent
Part #

Z2

L2

Nominal Effective Length


Diameter Z1 Z2 Z3
30
16 62 66
40
24 76 82
50
24 96 102
5040 12 84 92

ACY30S
ACY40S
ACY50S
ACY501S

L1

L3

Z1

Z3

45

L1
39
50
60
48

<Rigid PVC Injection Molded Product>


Socket

Unit:mm
L

Nominal
Diameter

Effective
Length Z

20
25
2520
30
3025
40
4030
50
5040

11
11
13
11
12
11
13
11
13

49
49
51
57
54
63
62
83
75

120
240
80
160
180
80
100
40
60

Adapter (Transition Fitting to PVC Pipe)


L

Nominal Diameter 20, 25

Unit:mm

Nominal Effective
Diameter Length Z

Nominal Diameter 30, 40, 50

NEW
Unit:mm
Nominal Effective
Diameter Length Z

L
Z

40
50

80
84

Spigot Length Spigot Quantity


Ivory
per
L
Part #
side Fitting Package
D
ACMD40
48 72 105 MD Fitting40 12
ACMD50
60 76 119 MD Fitting50 25

Transparent
Part #
ACMD40S
ACMD50S

Remarks: 1. Connect identical nominal diameter AC Drain Pipe for socket side.
Connect MD Fitting for spigot side
(Do not apply TS Fitting or DV Fitting for spigot side)
2. Do not cut and use spigot
3. Conduct thermal insulation for spigot side

Adapter for MD Fitting

ACA20S
ACA25S
ACA30S
ACA40S
ACA50S

Lineup of Eslon AC Drain Pipe and Fittings


Related Products
Screw type cleaning hole <Rigid PVC Injection Molded Product>
Unit:mm
AC Drain
Clamp Torque Quantity
Nominal D1 D2 D3 L1
L2
L3
(N m)
per package
Diameter
41 27 32 19 42.5 17.5
2
20
200
45 32 38 19 41.2 19.5
2
25
200
55 41 48 23 44.5 24
4
30
240
68 51 60 26 47.5 29
5
40
132
84 69 76 36 57.5 36
5
50
68
Remarks: 1. Do not use where contacting water continuously.
It may cause water condensation.
2. 1 Size larger nominal diameter is stated to AC Drain.

Ivory
Part #
JNCO25N
JNCO30N
JNCO40N
JNCO50N
JNCO65N

L3

L1

L2

O Ring

D2
D3

D1

AC Drain Flexible Unit <Equipment Side Elbow: Foamed ABS Injection Molded Product, Plumbing Side Socket: Rigid PVC Injection Molded Product>
Unit:mm
Nominal
Diameter Material
25

d1

Equipment Side 32.25


Pipe Side 38.25

d2
31.85
37.85

Z1
25
18

Z2

L1

35 36
-

60
31

Quantity
Ivory
per
L2
package Transparent

73
-

ACFU25

Remarks: Equipment side meets to VP25 and Pipe side meets AC Drain 25

Protective Tape

Plumbing
Side Socket

L2

d2

d1

L1

d1

d2

1,000

Equipment
Side Elbow

L1

Use it as standard adhesive for AC Drain

Eslon Adhesive
No. 73S Blue
<Colored Adhesive>

No. 75S Blue N


<Colored low viscosity type>

Volume:
500g (w/ Brush)
1 kg (w/ Brush)

Volume:
500g (w/ Brush)
1 kg (w/ Brush)

Remarks: Use either No. 73S Blue or No. 75S Blue N for transparent AC Drain Fitting.

No.73S

No.75S

Volume:
500g (w/ Brush)
1 kg (w/ Brush)

Volume:
500g (w/ Brush)
1 kg (w/ Brush)

Installation procedure of Eslon AC Drain Pipe and Fittings


Installation Process

1
2

Cut
Mark cutting line for whole
circumference and cut at right
angle against axis by saw.

Please use adhesive No. 73S Blue or No.


75S Blue N for transparent AC Drain fitting.
Please apply adhesive not only to inner
surface of fitting, outer surface of pipe but
also to the edge face of pipe.

Chamfer
Conduct light-chamfering for both
inner and outer surface on the
edge of pipe.

Apply adhesive for outer surface of pipe

Apply adhesive
for edge face of pipe

<Ivory>
Insert pipe quickly till marked
section is covered.
<Transparent>
Insert pipe quickly till the end.

Remove sand, soil or dust, etc.


and water content attached to the
inner surface of socket or inserting
section of pipe by cloth.

Hold (wipe off adhesive / ventilation)


Hold pipe and fittings more than 30
seconds.
Wipe off adhesive that comes out of
the section by cloth.
Please provide sufficient ventilation
after insertion.

Mark inserting length


Mark inserting length to the pipe
stated below.

Reference) Inserting Length

The outer diameter of AC Drain Pipe against nominal diameter is identical to 1 size larger
outer diameter of PVC pipe. Thus, supporting claps, etc. for PVC pipe can be used.

Unit: mm

Nominal Diameter

20

25

30

40

50

Inserting Length

19

19

23

26

36

Arrange the pitch of support to AC Drain Pipe identical to standard VP pipe whose
diameter is identical.

Connection to different pipe

Please make sure to use AC Drain Transition Fitting


to connect to the difference pipe.

(1) Connecting AC Drain Pipe to PVC


pipe in nominal diameter of 20
and 25 (use TS Fitting)

(2) Connecting AC Drain Pipe to PVC


pipe in nominal diameter of 30,
40 and 50 (use DV Fitting)

Connect with the combination of adapter fitting


and TS fitting.

Connect with the combination of adapter fitting


and DV fitting.

Thermal insulation is required for VP Pipe and TS Fitting.


Caution
*Can
be used to connect to drain hose as well.

Caution
Caution

<In case the size is 25>

VP Pipe 25

VP
25 25
TSPipe
Fitting

Thermal insulation is required for VP Pipe and DV Fitting.


The dimension of inserting section is for DV fitting. TS fitting
cannot be used.

<In case the size is 50>

AC Drain Pipe
AC
Pipe50
VP 25
Pipe 25
VPDrain
Pipe
Adapter
TS Fitting
TS Fitting
25
25 Adapter
25
25
25

Marking
for inserting section

Insert

Wipe off

* Clean with slight amount of industrial alcohol in


case oil is attached to the connecting section.

Apply Eslon adhesive (No. 73S Blue, No. 75S


Blue N, No. 73S, No. 75S) evenly to inner
surface of fitting, at the edge face of pipe
and outer surface of pipe.

Do not use PVC cutter, etc.


that may cause crack or chap.

In case of rough surface, it would remove


adhesive on the socket and cause loose.

Apply adhesive

AC Drain
Pipe
Pipe
Drain
Pipe
DV
Fitting
DV Fitting
DV Fitting
Adapter
VP
Pipe AC
50
VPAdapter
Pipe 50 AC Drain
Adapter
50
25
50
50
50 50 50 50
25

Use MD Fitting Adapter.


Caution
Caution
Caution

Do not cut spigot.


Do not connect to TS or DV Fitting for spigot side.
Need thermal insulation treatment on inserting area of MD
Fitting Adapter and MD Fitting

<In case the size is 40>

Adapter AC Drain Pipe


50
50

MD Fitting
Fitting
MDMD
Fitting
TS Socket in sameTS
nominal
Socketdiameter
in same nominalTS
diameter
Socket in same nominal
DV Socket
diameter
in sameDV
nominal
Socketdiameter
in same nominalDV
diameter
Socket in same
diameter
40 nominalConnecting
40
Adapter 40

(3) In case connecting MD Fitting and


AC Drain Pipe

AC MD
Drain
AC Drain MD Fitting
Fitting MD Fitting
Pipe
40
Pipe 40 Connecting
40
Connecting
Adapter 40
Adapter 40

AC Drain
Pipe 40

Installation Procedure of AC Drain Flexible Unit


Installation Process

Air conditioner and horizontal drain plumbing


Arrange the distance of plumbing below 700mm between
flexible hose attached to air conditioner and horizontal drain
plumbing. Also, please arrange the maximum height of AC
Drain Flexible Unit less than the maximum height specified
by air conditioner manufacturer.

Fix support of elbow on device side


Fix support firmly to dent of elbow on device side
(Supporting clasp: 65A for Vinyl SU pipe)

Dent
Support and Fix

Extended View

Air Conditioner

Hose Band

Chamfer
Flexible Hose

Socket

VP25

AC Drain Pipe,
Fitting

Air Conditioner

Flexible Hose

Connect supporting clasp to the dent of elbow on device side, and fix flexible hose
not to deflect it.

Height

Elbow

Below 700mm
Length of horizontal plumbing

In case of bringing up AC Drain Flexible Unit from air conditioner, the height should
be arranged less than the maximum height air conditioner manufacturer specifies.
Also, the length of horizontal plumbing should not have excess tension (less than
700mm).

Connect socket to pipe side


Apply Eslon adhesive evenly to socket on pipe side and Drain
horizontal plumbing (AC Drain Pipe 25A), and insert till the
end.

Check the position of support


Check connecting position of elbow on air conditioner side to
decide the position of support.

Air Conditioner

Horizontal Drain Plumbing.


(AC Drain Pipe, Fitting)

Apply
adhesive to
edge face of pipe

Plumbing
side socket

Air Conditioner

Flexible Hose

Flexible Hose

AC Drain Pipe
Socket
on pipe side

Socket on pipe side

Apply adhesive to outer surface of pipe

Secure
the hanging position
of support

AC Drain Pipe
Indicating mark for insertion

Do not drag or bend from elbow too much.


Also, do not twist heat insulating flexible pipe.
*Apply adhesive to edge face of AC Drain Pipe in case of
connecting AC Drain Pipe to socket on pipe side.

Elbow

Elbow on device side requires support. Please make sure to arrange support to it.

Elbow on device side


Supporting clasp: 65A for Vinyl SU pipe

Flexible Hose

Twist of heat insulating flexible pipe

Connection of Elbow on device side


Apply Eslon adhesive (No. 73S Blue, No. 75S Blue N, No.
73S, No. 75S) evenly to elbow on device side and VP 25
connected to the edge of flexible hose.
Then, insert till the end.

Fix support for heat insulating flexible pipe


Wrap protective tape at the top of bring up section, and
firmly fix the support.
(Applicable supporting claps : 32A for SGP Pipe)
Fix and support heat insulating
flexible pipe + wrap by protective tape
included in the package

Flexible Hose

Protective Tape

Flexible Hose

Air Conditioner

Air Conditioner

Elbow

Flexible Hose

Elbow

Socket
on pipe side

Heat insulating flexible pipe

Wrap by protective tape included in the package before fixing heat insulating flexible
pipe by claps.
Please do not cause back draft from brought up section.
Please do not drag or bend heat insulating flexible pipe too much.
Please do not bend heat insulating flexible pipe less than minimum bending radius of
111mm.

Please pay attention not to apply adhesive to thermal insulating flexible pipe.
Please check VP25A short pipe is feasible to connect in case of using flexible
hose included as attachment to an air conditioner. Also, please note insulation
treatment is needed for that short pipe section.
*Please follow standard procedure for DV fitting in case connecting by adhesive.

Performance of Eslon AC Drain Pipe, Fitting and AC Drain Flexible Unit


<Design>

Capability to prevent moisture condensation

Water Temperature
Water Temperature
15C
15C
100

90
85

85

80
75
70

75

to cause
not to cause
70Area not Area
water condensation
water condensation
65

65
60

80

10

60
15
10
15
20
20
25
30
25
Outer Temperature
Outer Temperature
( C )
( C )

80
75
70

Pipe Slope 1/50

100
95
Relative Humidity (%)

95

90

Relative Humidity (%)

95

Area water
Area water 95
condensation
condensation
occurs occurs 90

85

Nominal diameter 25, Flow amount 3 liter/hour,

Water Temperature
Water Temperature
10C
10C

100

Relative Humidity (%)

Relative Humidity (%)

100

Condition:

65
60
3010

90

Area water
Area water
condensation
condensation
occurs occurs

Performance of AC Drain Pipe and Fittings in horizontal


Caution

85

plumbing, and AC Drain Flexible Unit on brought up section.


Please conduct thermal insulation separately in case AC

80

Drain Pipe and Fittings are applied for full water area

75

including brought up section.

to cause
not to cause
70Area not Area

It may not needed depends on the condition. Please check

water condensation
water condensation
65
60
15
10
15
20
20
25
30
25
Outer Temperature
Outer Temperature
( C )
( C )

the condition to determine.


30

[Note]
VP Pipe......... Standard PVC Pipe which is durable for water hammer pressure of 1.0MPa
DV Fitting...... PVC fitting for non pressure application including drainpipe
TS Fitting...... PVC fitting for pressure application
MD Fitting..... Cast finishing fitting for non pressure application
SU Pipe........ Thin walled PVC Pipe
Those definitions come from Japanese Industrial Standards. Please consult in case detailed information is needed.

10

Precautions to use
1.Cautions at the stage of planning

Please pay attention not to cause buckling in case supporting


material is used.

This is piping material for drainage of air conditioner. Do not use


for pressure application except air conditioner pump up application
(below 1mm).

Do not use hose which had buckling or stepped on even there is


no visual damage.

Please arrange thermal insulation for the section where water is


full such as at the top of pump up section. Water condensation
may occurr in that area. It may not happen depends on the
condition, but please check it.

Please replace to new hose in case of re-arranging plumbing such


as renewal of air conditioner. It is not feasible for reuse once
installed.
Arrange minimum bending radius within 3 times of outer diameter
for Drain Pipe.

The applicable area is for indoor only. Do not apply for exterior.
Treatment with Fi-Block is required for area where fire proof is
required.

6. Other cautions
Cut and remove the section in case there is crack, dint or
deflection.

Steel bar hook (all screw bolt hook) is standard procedure for
horizontal plumbing.

In case pipe and fittings are attacked by creosote, asphalt,


antiseptic, waterproof agent or ketone, it may swell and break.
Please avoid contact of those materials to pipe and fittings.

Straight plumbing should be less than 30 meter. Arrange elbow


every 30 meters (more than 2 elbows: Pitch of elbow more than
0.5 meter).

Do not run liquid that containts solvent, ethanol, chlorine,


glycoether or ricinus. It may break pipe and result in leakage of
liquid. Please pay attention especially when cleaning inside of air
conditioner by chemical solution.

2.Caution at storage
Arrange the pitch of support to AC Drain Pipe identical to same
size of PVC pipe (VP).
Store pipe and fittings inside of a room. Cover by sheet with
avoiding to retain heat in case it needs to store outside.

Do not step on or hang on pipe.


Avoid fire cause near this product that comes from spark by
electric welding, torch lamp or gas barner, etc.

Do not use fire in storage room. Fire spark or heat may cause
damage to pipe and fittings.

Follow the instruction from gas equipment manufacturer and


association concerning the distance to gas equipment such as gas
water heater. The condition may differ by the type of equipment.
Thus, please consult the distance with gas business operator or
manufacturer.

Do not store solvent or paint in storage room. Attack by organic


solvent, etc. may cause damage.
3. Caution for transportation
Whole coverage by corrugate board is required, since AC Drain
pipe has foamed layer and soft. Need to be handled more carefully
than PVC pipe. Never drag or throw.

Do not allocate pipes near direct heat such as stove burner.


Do not flush chemical content such as solvent, ethanol or chlorine
based material. It may break pipe and results in leakage. Please
pay attention especially when cleaning the equipment by chemical
solution.

4.Caution for installation of AC Drain Pipe and Fittings


Use Eslon Adhesive No. 73S Blue, No. 75S Blue N, No. 73S, No.
75S.
Use Eslon Adhesive No. 73S Blue or No. 75S Blue N for
transparent AC Drain Fitting.

Cautions

Please follow instruction to install Eslon AC Drain Pipe and Fittings


on page 8.

In case the volume of adhesive exceeds allowable level, regulation


of intoxiation prevention may apply. Detail needs to be checked
with local labor standards inspection office.
Please pay attention to fire during installation, since organic
solvent such as adhesive is used.

Please follow the requirements stated below for connection


between AC Drain and PVC pipe.The gap at the joint may cause
accumulation of water or moisture condensation.

Please conduct sufficient ventilation when adhesive is used.


Remove adhesive immediately in case it contacts to skin. Please
see doctor if feel sick or unusual.

** Make sure to use AC Drain plumbing system with combination


of AC Drain Pipe and AC Drain Fittings.

Some sealing material contains plasticizer (phthalate, DOP, etc.) or


organic solvent (xylene, toluene) that may have negative effect on
PVC pipe or fitting. Please do not use sealing material that contains
those component.

** Make sure to use adapter fitting (refer to page 6) to connect AC


Drain Pipe and PVC pipe.
Use 1 size larger fitting of PVC pipe for screw type cleaning hole
(joint section needs another thermal insulation).

Cable that contains plasticizer may have negative effect on pipe or


fitting. Please avoid direct contact of those cables to pipe and
fittings.

5. Caution for installation of AC Drain Flexible Unit


Do not drag or bend from the point of fitting.

Please consut us in case there is some skeptical use but not


specified in this.

Do not step on fitting, hose or area where is close to joint. Do not


use hose once it has been stepped on even there is no damage
visually.
Please minimize the twist for plumbing.
Do not flush chemical liquid (surface activating agent, organic
solvent, acid, alkali, etc) or solid content except drain.

Please follow the instruction and conduct safe and secured


installation for Eslon AC Drain Pipe and Fittings.

11

*Please note we cannot take responsibility for damage or accident in case


of use without following the instruction stated here.

Urban Infrastructure & Environmental Products Company

http://www.eslontimes.com/en/

Colors of the actual products may vary from the


colors shown in this printed material.
Information in this document is subject to change
without notice.

All rights reserved.

Oct. 2013 First Edition


Eslon AC Drain Pipe and Fittings
Catalog

SEKISUI CHEMICAL CO.,LTD.


Urban Infrastructure &
Environmental Products Company