You are on page 1of 2

Materials:

All the materials and workmanship shall be according to the AASHTO specifications and ASTM
standards except where modified below, or in particular specifications and special provisions of
tender documents.
Bearing Pads:
Bearing pads shall conform to section 14, Elastomeric Bearing of AASHTO specifications for
highway bridges 1995.
Construction & Erection:
Concrete in deck slab shall be placed in full width and construction joint shall be permitted
and deck slab shall be cast monolithically.
Concrete for the barriers and sidewalls shall be placed no sooner than 20 days after placing of
concrete in the deck slab.
Girders shall be installed in their correct position on bearings by lifting or launching and shall be
temporarily braced until casting of diaphragms.
If lifted method is used, girder shall be lifted from both ends using lifting holes/sleeves by means
approved by the engineer.
If launching is used the maximum cantilever overhang shall not exceed 2m.
All faces of concrete in abutments and wing walls in contact with soil shall be damp proofed
with two layers of bituminous material with no extra cost.
All exposed surfaces shall have fair faced finish unless otherwise specified.
Behind the abutment and wing walls a selected granular fill shall be provided.
Post-Tensioning:
All cables shall be stressed simultaneously from both ends in the order specified in the drawings.
The jacking force, cable elongation and locking slippage shall be in accordance with the
drawings. Any deviation or variation must be reported to the engineer before continuing stressing
work.
The cable axis must coincide with the anchorage axis behind the anchorage for a length of at
least 400 mm or trumpet length, whichever is greater.
Suitable steel chairs/frames to hold the Prestressing cable ducts and reinforcement in true
position at adequate intervals (Ranging from 08 to 12 meters) shall be provided.
Provisions shall be made in the end anchorage for grouting the cable immediately after
tensioning. After securing the end anchorages, all cables shall be pressure grouted in their ducts
in accordance with the specifications.

Intermediate grout vents shall be provided near the lowest end of the cable profile at about midlength of the cables. Cables shall be grouted after stressing with the FEB-Flow cable/Flowcable50 or equivalent as approved by the engineer. Anchorage pockets shall be filled with 210 KG/ 50
CM (3000 psi) concrete using 10mm down aggregate after grouting and trimming cables.
The following shall be assumed in the calculation of theoretical elongation, Ao:
Modulus of Elasticity, E = 193,000 Mpa (26000 ksi)
Coefficient of friction = 0.25/radian
Wobble coefficient = 0.0033/meter
Draw-in of wedges for, 0.5 (12.7mm) strand = 5mm.
Unless otherwise noted the cylinder strength of concrete in Prestressed concrete post-tension
girder at transfer shall not be less than
Expansion Joints:
Expansion joints system shall be approved by the engineer. Allowable movement between
maximum and minimum gap ae 25mm in the direction of traffic except as indicated. E system
shall be installed at least one month after completing the deck. By saw cutting in the continuous
wearing course contractor shall submit necessary installation details for engineers approval
before starting the work.