You are on page 1of 16

Miniature Pressure Switches and

Vacuum Switches

Table of Contents

P550 Value Low Pressure Switch

ISO9001:2008 Certified

Cat. 100 Rev 001

2245 A Street, Santa Maria, CA 93455 USA


www.wascoinc.com
e-mail: sales@wascoinc.com
(805) 739-2747 * FAX (805) 739-2751

Technical Specifications
No.

Name

Requirements

Activation Point Range

0.5 - 15 PSI

Activation Point Tolerance

See Table I

Temperature Range

Leak Rate

Weight

RoHS compliant

-65 F to + 225 F
1.0 x 10-3 cc/min Air
2.0 oz (typical with 12 inch W3 electrical interface)

Electrical Rating
Max. Amp Rating

Volts
AC/DC

Amp
Resistive

Amp
Inductive

Contact
Material

115/28

1/1

1/0.5

Gold

250/28

5/5

5/3

Silver

250/28

7/7

7/4

Silver

Material Specifications P550


Wetted

Non Wetted

Body/Fitting

6061-T6 Aluminium
Anodized

Electrical Interface Steel (zinc chromate


finish)

Diaphragm

300 Series Stainless


Steel

Lock Ring

O-Ring

Buna N, other
compounds available

O-Ring Retainer

300 Series Stainless


Steel

Steel (zinc chromate


finish)

This Model is Not Adjustable


Operating Pressure Range and Standard Tolerances
Table I - Positive Pressure Activation Points P550 Series
Sensor

Max Operating
Pressure (PSI)

Activation Point
Range (PSI)

Activation Point
Tolerance () (PSI)

Reset Band
(PSI)

75

0.5 - 15

0.5

0.4 - 1.8

Custom specifications available

3
ISO9001:2008 Certified

Cat. 100 Rev 001

2245 A Street, Santa Maria, CA 93455 USA


www.wascoinc.com
e-mail: sales@wascoinc.com
(805) 739-2747 * FAX (805) 739-2751

Value

Table of Contents ............................................................................... 2


P550 Value Pressure Switch ............................................................. 3
P500 Value Pressure Switch .............................................................. 4
V500 Value Vacuum Switch .............................................................. 5
P110 Standard Pressure Switch ........................................................ 6
V110 Standard Vacuum Switch ......................................................... 7
SP120 Super Purity Pressure Switch ............................................... 8
SV120 Super Purity Vacuum Switch ................................................ 9
UHP150 Ultra High Purity Pressure Switch .................................... 10
UHP160 Ultra High Purity Vacuum Switch ..................................... 11
TP700 Dual Pressure Switch .......................................................... 12
TV700 Dual Vacuum Switch ........................................................... 13
P250 Pressure Switch w/ Overpressure Protection ........................ 14
V250 Vacuum Switch w/ Overpressure Protection .......................... 15
P325 Pressure Switch w/ Overpressure Protection ........................ 16
P400 Pressure Switch w/ Overpressure Protection ........................ 17
DP30 Solid State Differential Pressure Switch ................................ 18
DV40 Solid State Differential Vacuum Switch ................................. 19
Solid State Technical Data .............................................................. 20
Solid State Low Pressure Switches ................................................. 20
Solid State High Pressure Switches ................................................ 21
Solid State Vacuum Switches ......................................................... 21
How to Order: Capsule Switches ....................................................... 22
How to Order: Overpressure Protected Switches .............................. 23
How to Order: High Purity Switches ................................................... 24
How to Order: Differential Switches.................................................... 25
How to Order: Solid State Switches ................................................... 26
Electrical Interface ............................................................................. 27
Process Fittings ................................................................................. 27
Enclosures ......................................................................................... 29
Glossary ............................................................................................. 30
Return Policy ..................................................................................... 30
Warranty ............................................................................................. 30

P500 Value Pressure Switch

V500 Value Vacuum Switch


Technical Specifications

Requirements

Activation Point Range

2 - 500 PSI

Activation Point Tolerance

See Table II

Temperature Range

Leak Rate

Weight

RoHS compliant

-65 F to + 225 F
1.0 x 10 cc/min Air
-3

2.5 oz (typical with 12 inch W3


electrical interface)

Value

Name

No.

Name

Activation Point Range

Activation Point Tolerance

Temperature Range

Leak Rate

Weight

Electrical Rating
Max. Amp Rating

Requirements
2.0 - 29.5 inHg

RoHS compliant

See Table III


-65 F to + 225 F
1.0 x 10-3 cc/min Air
2.5 oz (typical with 12 inch W3
electrical interface)

Electrical Rating

Volts
AC/DC

Amp
Resistive

Amp
Inductive

Contact
Material

Max. Amp Rating

115/28

1/1

250/28

5/5

250/28

7/7

Volts
AC/DC

Amp
Resistive

Amp
Inductive

1/0.5

Gold

5/3

Silver

7/4

Silver

Contact
Material

115/28

1/1

1/0.5

Gold

250/28

5/5

5/3

Silver

250/28

7/7

7/4

Silver

Material Specifications P500

Material Specifications V500

Wetted

Wetted

Non Wetted

Non Wetted

Body/Fitting

Brass

Electrical Interface Steel (zinc chromate


finish)

Body/Fitting

Brass

Electrical Interface

Steel (zinc chromate


finish)

Locking Compound

Loctite 277

Lock Ring

Locking Compound

Loctite 277

Lock Ring

Steel (zinc chromate


finish)

O-Ring

Buna N, other
compounds available

O-Ring

Buna N, other
compounds available

Sensor

17-7PH Stainless
Steel and 300
Stainless Steel

Sensor

17-7PH Stainless
Steel and 300
Stainless Steel

Steel (zinc chromate


finish)

Pressure Switch Adjustment (if field adjustable)


This model may be adjusted by loosening the Lock Ring and turning the electric switch housing counter clockwise
to raise the activation point, clockwise to lower the activation point. Holding the electric switch housing in position,
tighten the Lock Ring and check the activation point. Repeat preceding adjustment instructions if necessary.

Operating Pressure Range and Standard Tolerances


Max Operating
Pressure (PSI)

Activation Point
Range (PSI)

Note: V500 Series sensor will be damaged if positive pressure is applied

Operating Vacuum Range and Standard Tolerances

Table II - Positive Pressure Activation Points P500 Series


Sensor

Vacuum Switch Adjustment (if field adjustable)


This model may be adjusted by loosening the Lock Ring and turning the electric switch housing clockwise to raise
the activation point, counter clockwise to lower the activation point. Holding the electric switch housing in position,
tighten the Lock Ring and check the activation point. Repeat preceding adjustment instructions if necessary.

Activation Point
Tolerance () (PSI)

Reset Band
(PSI)

30

2 - 30

1.0

1.0 - 2.0

125

5 - 125

3.0

2.0 - 3.0

250

10 - 250

7.0

15

500

22 - 500

10.0

Table III - Vacuum Activation Points V500 Series


Sensor

Max Operating
Pressure (inHg)

3.0 - 8.0

30.0

8.0 - 18.0

30.0

Custom specifications available

4
ISO9001:2008 Certified

Cat. 100 Rev 001

Activation Point
Range (inHg)

Activation Point
Tolerance () (inHg)

Reset Band
(inHg)

2.0 - 29.5

2.0

1.0 - 4.6

10.0 - 29.5

4.0

1.4 - 7.6

Custom specifications available


2245 A Street, Santa Maria, CA 93455 USA
www.wascoinc.com
e-mail: sales@wascoinc.com
(805) 739-2747 * FAX (805) 739-2751

5
ISO9001:2008 Certified

Cat. 100 Rev 001

2245 A Street, Santa Maria, CA 93455 USA


www.wascoinc.com
e-mail: sales@wascoinc.com
(805) 739-2747 * FAX (805) 739-2751

Value

Technical Specifications
No.

V110 Standard Vacuum Switch

P110 Standard Pressure Switch


Name

Activation Point Range

1.0 - 500 PSI

Activation Point Tolerance

See Table IV

Temperature Range

Leak Rate

Weight

Technical Specifications

Requirements

RoHS compliant

Standard

-65 F to + 225 F
1.0 x 10 cc/min Air
-3

3.5 oz (typical with 12 inch W3


electrical interface)

Electrical Rating
Max. Amp Rating

Volts
AC/DC

Amp
Resistive

Amp
Inductive

Contact
Material

115/28

1/1

1/0.5

Gold

250/28

5/5

5/3

Silver

250/28

7/7

7/4

Silver

No.

Name

Activation Point Range

Activation Point Tolerance

Temperature Range

Leak Rate

Weight

1.5 - 29.5 inHg

RoHS compliant

See Table V
-65 F to + 225 F
1.0 x 10-3 cc/min Air
3.5 oz (typical with 12 inch W3
electrical interface)

Electrical Rating
Max. Amp Rating

Volts
AC/DC

Amp
Resistive

Amp
Inductive

115/28

1/1

1/0.5

Gold

250/28

5/5

5/3

Silver

250/28

7/7

7/4

Silver

Material Specifications P110


Wetted

Requirements

Standard

Technical Specifications
No.

Contact
Material

Material Specifications V110

Non Wetted

Wetted

Non Wetted

Body/Fitting

300 Series Stainless


Steel

Electrical Interface Steel (zinc chromate


finish)

Body/Fitting

300 Series Stainless


Steel

Electrical Interface Steel (zinc chromate


finish)

Locking Compound

Loctite 277

Lock Ring

Locking Compound

Loctite 277

Lock Ring

O-Ring

Buna N, other
compounds available

O-Ring

Buna N, other
compounds available

Sensor

17-7PH Stainless
Steel and 300 Series
Stainless Steel

Sensor

17-7PH Stainless
Steel and 300 Series
Stainless Steel

Steel (zinc chromate


finish)

Pressure Switch Adjustment (if field adjustable)


This model may be adjusted by loosening the Lock Ring and turning the electric switch housing counter clockwise
to raise the activation point, clockwise to lower the activation point. Holding the electric switch housing in position,
tighten the Lock Ring and check the activation point. Repeat preceding adjustment instructions if necessary.

Steel (zinc chromate


finish)

Vacuum Switch Adjustment (if field adjustable)


This model may be adjusted by loosening the Lock Ring and turning the electric switch housing clockwise to raise
the activation point, counter clockwise to lower the activation point. Holding the electric switch housing in position,
tighten the Lock Ring and check the activation point. Repeat preceding adjustment instructions if necessary.
Note: V110 Series sensor will be damaged if positive pressure is applied

Operating Pressure Range and Standard Tolerances


Operating Vacuum Range and Standard Tolerances

Table IV - Positive Pressure Activation Points P110 Series


Sensor

Max Operating
Pressure (PSI)

Activation Point
Range (PSI)

Activation Point
Tolerance () (PSI)

Reset Band
(PSI)

30

1 - 30

0.7

0.7 - 2.3

125

3 - 125

2.0

1.3 - 3.8

250

8 - 250

5.0

2.0 - 10.0
5.0 - 21.0

15

500

18 - 500

10.0

Table V - Vacuum Activation Points V110 Series


Max Operating
Pressure (inHg)

Activation Point
Range (inHg)

Activation Point
Tolerance () (inHg)

Reset Band
(inHg)

30.0

1.6 - 29.5

1.5

1.0 - 4.6

30.0

6.0 - 29.5

4.0

1.4 - 7.6

Sensor

Custom specifications available

6
ISO9001:2008 Certified

Cat. 100 Rev 001

Custom specifications available


2245 A Street, Santa Maria, CA 93455 USA
www.wascoinc.com
e-mail: sales@wascoinc.com
(805) 739-2747 * FAX (805) 739-2751

7
ISO9001:2008 Certified

Cat. 100 Rev 001

2245 A Street, Santa Maria, CA 93455 USA


www.wascoinc.com
e-mail: sales@wascoinc.com
(805) 739-2747 * FAX (805) 739-2751

SP120 Super Purity Pressure Switch

SV120 Super Purity Vacuum Switch

Technical Specifications
Name

Activation Point Range

1.0 - 500 PSI

Activation Point Tolerance

See Table VI

Temperature Range

Technical Specifications

Requirements

Leak Rate

Weight

RoHS compliant

-65 F to + 225 F
10-9

1.0 x
Tested)

cc/sec He (Helium Leak

3.5 oz (typical with 12 inch W3


electrical interface)

Max. Amp Rating

Volts
AC/DC

Amp
Resistive

Amp
Inductive

115/28

1/1

1/0.5

Gold

250/28

5/5

5/3

Silver

250/28

7/7

7/4

Silver

High Purity

Electrical Rating
Contact
Material

No.

Name

Activation Point Range

Activation Point Tolerance

Temperature Range

Leak Rate

Weight

1.5 - 29.5 inHg

RoHS compliant

See Table VII


-65 F to + 225 F
1.0 x 10-9 cc/sec He (Helium Leak
Tested)
3.5 oz (typical with 12 inch W3
electrical interface)

Electrical Rating
Max. Amp Rating

Volts
AC/DC

Amp
Resistive

Amp
Inductive

115/28

1/1

1/0.5

Gold

250/28

5/5

5/3

Silver

250/28

7/7

7/4

Silver

Material Specifications SP120


Wetted

Requirements

High Purity

No.

Contact
Material

Material Specifications SV120

Non Wetted

Wetted

Non Wetted

Body/Fitting

316 Stainless Steel

Electrical Interface

Steel (zinc chromate


finish)

Body/Fitting

316 Stainless Steel

Sensor

17-7PH Stainless Steel and


316 Series Stainless Steel

Lock Ring

Steel (zinc chromate


finish)

Sensor

17-7PH Stainless Steel and Lock Ring


316 Series Stainless Steel

Pressure Switch Adjustment (if field adjustable)


This model may be adjusted by loosening the Lock Ring and turning the electric switch housing counter clockwise
to raise the activation point, clockwise to lower the activation point. Holding the electric switch housing in position,
tighten the Lock Ring and check the activation point. Repeat preceding adjustment instructions if necessary.

Electrical Interface

Steel (zinc chromate


finish)
Steel (zinc chromate
finish)

Vacuum Switch Adjustment (if field adjustable)


This model may be adjusted by loosening the Lock Ring and turning the electric switch housing clockwise to raise
the activation point, counter clockwise to lower the activation point. Holding the electric switch housing in position,
tighten the Lock Ring and check the activation point. Repeat preceding adjustment instructions if necessary.
Note: SV120 Series sensor will be damaged if positive pressure is applied

Operating Pressure Range and Standard Tolerances


Operating Vacuum Range and Standard Tolerances

Table VI - Positive Pressure Activation Points SP120 Series


Sensor

Max Operating
Pressure (PSI)

Activation Point
Range (PSI)

Activation Point
Tolerance () (PSI)

Reset Band
(PSI)

30

1 - 30

0.7

0.7 - 2.3

125

3 - 125

2.0

1.3 - 3.8

250

8 - 250

5.0

15

500

18 - 500

10.0

Table VII - Vacuum Activation Points SV120 Series


Sensor

Max Operating
Pressure (inHg)

Activation Point
Range (inHg)

Activation Point
Tolerance () (inHg)

Reset Band
(inHg)

2.0 - 10.0

30.0

1.6 - 29.5

1.2 inHg

1.0 - 4.6

5.0 - 21.0

30.0

6.0 - 29.5

4.0 inHg

1.4 - 7.6

Custom specifications available

8
ISO9001:2008 Certified

Cat. 100 Rev 001

Custom specifications available


2245 A Street, Santa Maria, CA 93455 USA
www.wascoinc.com
e-mail: sales@wascoinc.com
(805) 739-2747 * FAX (805) 739-2751

9
ISO9001:2008 Certified

Cat. 100 Rev 001

2245 A Street, Santa Maria, CA 93455 USA


www.wascoinc.com
e-mail: sales@wascoinc.com
(805) 739-2747 * FAX (805) 739-2751

UHP150 Ultra High Purity Pressure Switch

UHP160 Ultra High Purity Vacuum Switch

Technical Specifications
Name

Activation Point Range

1.0 - 500 PSI

Activation Point Tolerance

See Table VIII

Temperature Range

Technical Specifications

Requirements

Leak Rate

Weight

RoHS compliant

-65 F to + 225 F
10-9

1.0 x
Tested)

cc/sec He (Helium Leak

3.5 oz (typical with 12 inch W3


electrical interface)

Max. Amp Rating

Volts
AC/DC

Amp
Resistive

Amp
Inductive

115/28

1/1

1/0.5

Gold

250/28

5/5

5/3

Silver

250/28

7/7

7/4

Silver

High Purity

Electrical Rating
Contact
Material

No.

Name

Activation Point Range

Activation Point Tolerance

Temperature Range

Leak Rate

Weight

1.6 - 29.5 inHg

RoHS compliant

See Table IX
-65 F to + 225 F
1.0 x 10-9 cc/sec He (Helium Leak
Tested)
3.5 oz (typical with 12 inch W3
electrical interface)

Electrical Rating
Max. Amp Rating

Material Specifications UHP150


Wetted

Requirements

Volts
AC/DC

Amp
Resistive

Amp
Inductive

115/28

1/1

1/0.5

Gold

250/28

5/5

5/3

Silver

250/28

7/7

7/4

Silver

High Purity

No.

Contact
Material

Material Specifications UHP160

Non Wetted

Wetted

Non Wetted

Body/Fitting

316 Stainless Steel

Electrical Interface

Steel (zinc chromate


finish)

Body/Fitting 316 Stainless Steel

Electrical Interface Steel (zinc chromate


finish)

Sensor

17-7PH Stainless Steel and


316 Stainless Steel

Lock Ring

Steel (zinc chromate


finish)

Sensor

Lock Ring

Pressure Switch Adjustment (if field adjustable)


This model may be adjusted by loosening the Lock Ring and turning the electric switch housing counter clockwise
to raise the activation point, clockwise to lower the activation point. Holding the electric switch housing in position,
tighten the Lock Ring and check the activation point. Repeat preceding adjustment instructions if necessary.

17-7PH Stainless Steel and


316 Stainless Steel

Steel (zinc chromate


finish)

Vacuum Switch Adjustment (if field adjustable)


This model may be adjusted by loosening the Lock Ring and turning the electric switch housing clockwise to raise
the activation point, counter clockwise to lower the activation point. Holding the electric switch housing in position,
tighten the Lock Ring and check the activation point. Repeat preceding adjustment instructions if necessary.
Note: UHP160 Series sensor will be damaged if positive pressure is applied

Operating Pressure Range and Standard Tolerances


Table VIII - Positive Pressure Activation Points UHP150 Series
Sensor

Max Operating
Pressure (PSI)

Activation Point
Range (PSI)

Activation Point
Tolerance () (PSI)

Reset Band
(PSI)

30

1 - 30

0.7

0.7 - 2.3

125

3 - 125

2.0

1.3 - 3.8

250

8 - 250

5.0

15

500

18 - 500

10.0

Operating Vacuum Range and Standard Tolerances


Table IX - Vacuum Activation Points UHP160 Series
Sensor

Max Operating
Pressure (inHg)

Activation Point
Range (inHg)

Activation Point
Tolerance () (inHg)

Reset Band
(inHg)

2.0 - 10.0

30.0

1.6 - 29.5

1.2

1.0 - 4.6

5.0 - 21.0

30.0

6.0 - 29.5

4.0

1.4 - 7.6

Custom specifications available

10
ISO9001:2008 Certified

Cat. 100 Rev 001

Custom specifications available

2245 A Street, Santa Maria, CA 93455 USA


www.wascoinc.com
e-mail: sales@wascoinc.com
(805) 739-2747 * FAX (805) 739-2751

11
ISO9001:2008 Certified

Cat. 100 Rev 001

2245 A Street, Santa Maria, CA 93455 USA


www.wascoinc.com
e-mail: sales@wascoinc.com
(805) 739-2747 * FAX (805) 739-2751

TP700 Dual Pressure Switch

TV700 Dual Vacuum Switch

Technical Specifications
No.

Name

Activation Point Range

1.0 - 500 PSI

Activation Point Tolerance

See Table X

Temperature Range

Leak Rate

Weight

Technical Specifications

Requirements

No.

Name

Activation Point Range

Activation Point Tolerance

-65 F to + 225 F

Temperature Range

1.0 x 10 cc/min Air

Leak Rate

8 oz (typical with 12 inch W3


electrical interface)

Weight

RoHS compliant

-3

Electrical Rating
Amp
Resistive

Amp
Inductive

115/28

1/1

250/28

5/5

250/28

7/7

Contact
Material

Max. Amp Rating

1/0.5

Gold

5/3

Silver

7/4

Silver

Dual

Material Specifications TP700


Body/Fitting

Non Wetted

Brass

Locking Compound Loctite 277

-65 F to + 225 F
1.0 x 10-3 cc/min Air
8 oz (typical with 12 inch W3
electrical interface)

Electrical Interface

Steel (zinc chromate


finish)

Lock Ring

Steel (zinc chromate


finish)

Volts
AC/DC

Amp
Resistive

Amp
Inductive

115/28

1/1

1/0.5

Gold

250/28

5/5

5/3

Silver

250/28

7/7

7/4

Silver

Wetted

Non Wetted

Body

Brass

Electrical Interface

Steel (zinc chromate


finish)

Locking Compound

Loctite 277

Lock Ring

Steel (zinc chromate


finish)

Buna N, other
compounds available

O-Ring

Buna N, other
compounds available

Sensor

17-7PH Stainless
Steel and 300 Series
Stainless Steel

Sensor

17-7PH Stainless
Steel and 300 Series
Stainless Steel

Pressure Switch Adjustment (if field adjustable)


This model may be adjusted by loosening the Lock Ring and turning the electric switch
housing counter clockwise to raise the activation point, clockwise to lower the activation
point. Holding the electric switch housing in position, tighten the Lock Ring and check the
activation point. Repeat preceding adjustment instructions if necessary.

Vacuum Switch Adjustment (if field adjustable)


This model may be adjusted by loosening the Lock Ring and turning the electric switch
housing clockwise to raise the activation point, counter clockwise to lower the activation
point. Holding the electric switch housing in position, tighten the Lock Ring and check the
activation point. Repeat preceding adjustment instructions if necessary.

Operating Pressure Range and Standard Tolerances


Activation Point
Range (PSI)

Note: TV700 Series sensor will be damaged if positive pressure is applied

Operating Vacuum Range and Standard Tolerances

Table X - Positive Pressure Activation Points TP700 Series


Max Operating
Pressure (PSI)

Activation Point
Tolerance () (PSI)

Reset Band
(PSI)

30

1 - 30

0.7

0.7 - 2.3

125

3 - 125

2.0

1.3 - 3.8

250

8 - 250

5.0

15

500

18 - 500

10.0

Table XI - Vacuum Activation Points TV700 Series


Sensor

Max Operating
Pressure (inHg)

2.0 - 10.0

30.0

5.0 - 21.0

30.0

ISO9001:2008 Certified

Cat. 100 Rev 001

Activation Point
Range (inHg)

Activation Point
Tolerance () (inHg)

Reset Band
(inHg)

2.0 - 29.5

1.5

2.0 - 4.0

10.0 - 29.5

5.0

3.0 - 7.0

Custom specifications available

Custom specifications available

12

Contact
Material

Material Specifications TV700

O-Ring

Sensor

RoHS compliant

See Table XI

Electrical Rating

Volts
AC/DC

Wetted

2.0 - 29.5 inHg

Dual

Max. Amp Rating

Requirements

2245 A Street, Santa Maria, CA 93455 USA


www.wascoinc.com
e-mail: sales@wascoinc.com
(805) 739-2747 * FAX (805) 739-2751

13
ISO9001:2008 Certified

Cat. 100 Rev 001

2245 A Street, Santa Maria, CA 93455 USA


www.wascoinc.com
e-mail: sales@wascoinc.com
(805) 739-2747 * FAX (805) 739-2751

P250 Pressure Switch with Overpressure Protection

V250 Vacuum Switch with Overpressure Protection

Technical Specifications
No.

Name

Activation Point Range

1.0 - 100 PSI

Activation Point Tolerance

See Table XII

Burst Pressure

Temperature Range

Leak Rate

Weight

Technical Specifications

Requirements

No.

Name

Activation Point Range

0.5 - 29.5 inHg

Activation Point Tolerance

See Table XIII

6,000 PSI

Burst Pressure

-65 F to + 225 F

Temperature Range

1.0 x 10-3 cc/min Air

Leak Rate

5 oz (typical with 12 inch W3


electrical interface)

Weight

RoHS compliant

RoHS compliant

6,000 PSI
-65 F to + 225 F
1.0 x 10-3 cc/min Air
5 oz (typical with 12 inch W3
electrical interface)

Electrical Rating

Volts
AC/DC

Amp
Resistive

Amp
Inductive

Contact
Material

Max. Amp Rating

115/28

1/1

250/28

5/5

250/28

7/7

Volts
AC/DC

Amp
Resistive

Amp
Inductive

1/0.5

Gold

5/3

Silver

7/4

Silver

Contact
Material

115/28

1/1

1/0.5

Gold

250/28

5/5

5/3

Silver

250/28

7/7

7/4

Silver

Material Specifications P250

Material Specifications V250

Wetted

Wetted

Diaphragm

Kapton or Stainless Steel

Adjusting Nut

Steel

Fitting

300 Series Stainless Steel

Body

300 Series Stainless


Steel

O-Rings

Buna N, other compounds


available

Electrical Interface

Screw

300 Series Stainless Steel

Locking Compound Loctite 277

Washer

300 Series Stainless Steel

Overpressure

Non Wetted

Steel (zinc chromate


finish)

Pressure Switch Adjustment (if field adjustable)


A change in the activation may be made by turning the adjusting ring located in the opening in the side of the body.
Causing the ring to turn left will raise the activation point, and turning it right will lower it. For the best results after
resetting the switch, cycle the system pressure level several times to stabilize the new activation point. Repeat
preceding adjustment instructions if necessary.

Diaphragm

Kapton or Stainless Steel

Actuator/Springs

Steel

Fitting

300 Series Stainless Steel

Adjusting Nut

Steel

O-Rings

Buna N, other compounds


available

Body

300 Series Stainless


Steel

Screw

300 Series Stainless Steel

Electrical Interface

Steel (zinc chromate


finish)

Washer

300 Series Stainless Steel

Locking Compound Loctite 277

Vacuum Switch Adjustment (if field adjustable)


A change in the activation may be made by turning the adjusting ring located in the opening in the side of the body.
Causing the ring to turn right will raise the activation point, and left will lower it. For the best results after resetting
the switch, cycle the system pressure level several times to stabilize the new activation point. Repeat preceding
adjustment instructions if necessary.

Operating Pressure Range and Standard Tolerances


Table XII - Positive Pressure Activation Points P250 Series
Sensor

Max Operating
Pressure (PSI)

Proof
Pressure (PSI)

Activation Point
Range (PSI)

Activation Point
Tolerance () (PSI)

Reset Band
(PSI)

4,000

5,000

1 - 10

0.2

0.5 - 1.5

4,000

5,000

10 - 20

0.4

Non Wetted

Overpressure

Electrical Rating
Max. Amp Rating

Requirements

Operating Vacuum Range and Standard Tolerances


Table XIII - Vacuum Activation Points V250 Series
Sensor

Max Operating
Pressure (PSI)

Activation Point
Range (inHg)

Activation Point
Tolerance () (inHg)

Reset Band
(inHg)

1.0 - 4.0

0*

3,000

0.5 - 2.0

0.3

1.0 - 3.5

3,000

2.0 - 5.0

0.3

1.0 - 3.5

4,000

5,000

20 - 35

0.7

2.0 - 5.0

4,000

5,000

35 - 60

1.2

4.5 - 8.0

3,000

2.5 - 12.0

0.4

1.5 - 6.0

7.0 - 15.0

3,000

10.0 - 29.5

0.4

3.0 - 8.0

4,000

5,000

60 - 100

2.0

Custom specifications available

14
ISO9001:2008 Certified

Cat. 100 Rev 001

2245 A Street, Santa Maria, CA 93455 USA


www.wascoinc.com
e-mail: sales@wascoinc.com
(805) 739-2747 * FAX (805) 739-2751

*Activation Point Range 0.5-2.0 inHg is decreasing vacuum only

Custom specifications available

15
ISO9001:2008 Certified

Cat. 100 Rev 001

2245 A Street, Santa Maria, CA 93455 USA


www.wascoinc.com
e-mail: sales@wascoinc.com
(805) 739-2747 * FAX (805) 739-2751

P325 High Pressure Switch with Overpressure Protection

P400 High Pressure Switch with Overpressure Protection

Technical Specifications
Name

Activation Point Range

Activation Point Tolerance

Burst Pressure

Temperature Range

Leak Rate

Weight

Technical Specifications

Requirements

No.

Name

Activation Point Range

Activation Point Tolerance

6,000 PSI

Burst Pressure

-65 F to + 225 F

Temperature Range

1.0 x 10-3 cc/min Air

Leak Rate

4.5 oz (typical with 12 inch W3


electrical interface)

Weight

400 - 6,000 PSI

RoHS compliant

See Table XIV

Electrical Rating
Max. Amp Rating

100 - 6,000 PSI

RoHS compliant

See Table XV
12,000 PSI
-65 F to + 225 F
1.0 x 10-3 cc/min Air
6.5 oz (typical with 12 inch W3
electrical interface)

Electrical Rating

Volts
AC/DC

Amp
Resistive

Amp
Inductive

115/28

1/1

250/28

5/5

250/28

7/7

Contact
Material

Max. Amp Rating

Volts
AC/DC

Amp
Resistive

Amp
Inductive

1/0.5

Gold

5/3

Silver

115/28

1/1

1/0.5

Gold

250/28

5/5

5/3

Silver

7/4

Silver

250/28

7/7

7/4

Silver

Material Specifications P325

Contact
Material

Material Specifications P400

Non Wetted

Wetted

Fitting

300 Series
Stainless Steel

Actuator/Springs

Steel

O-Ring

Buna N, other
compounds available

Body

300 Series Stainless


Steel

Piston

17-4 Stainless Steel

Electrical Interface

Steel (zinc chromate


finish)

Locking Compound

Loctite 277

Lock Ring

Steel (zinc chromate


finish)

Overpressure

Wetted

Requirements

Non Wetted

Diaphragm

Kapton or Stainless Steel

Actuator/Springs

Steel

Fitting

300 Series Stainless


Steel

Body

300 Series Stainless


Steel

O-Ring

Buna N, other
Electrical Interface
compounds available

Overpressure

No.

Steel (zinc chromate


finish)

Locking Compound Loctite 277


Piston

17-4 Stainless Steel

Pressure Switch Adjustment (if field adjustable)


This model may be adjusted by loosening the Lock Ring and turning the electric switch housing counter clockwise
to raise the activation point, clockwise to lower the activation point. Holding the electric switch housing in position,
tighten the Lock Ring and check the activation point. Repeat preceding adjustment instructions if necessary.

Pressure Switch Adjustment (if field adjustable)


A change in the activation may be made by turning the adjusting ring located in the opening in the side of the body.
Causing the ring to turn left will raise the activation point, and turning it right will lower it. For the best results after
resetting the switch, cycle the system pressure level several times to stabilize the new activation point. Repeat
preceding adjustment instructions if necessary.

Operating Pressure Range and Standard Tolerances

Operating Pressure Range and Standard Tolerances

Table XIV - Positive Pressure Activation Points P325 Series

Table XV - Positive Pressure Activation Points P400 Series

Sensor

Max Operating
Pressure (PSI)

Activation Point
Range (PSI)

Activation Point
Tolerance () (PSI)

Reset Band
(PSI)

Sensor

Max Operating
Pressure (PSI)

Activation Point
Range (PSI)

Activation Point
Tolerance () (PSI)

Reset Band
(PSI)

3,000

400 - 3,000

4%

40 - 150

6,000

900 - 6,000

4%

50 - 350

6,000

2
3

Custom specifications available

100 -

500

3%

15 - 60

6,000

400 - 2,500

3%

20 - 200

6,000

1,500 - 6,000

3%

100 - 600

Custom specifications available

16
ISO9001:2008 Certified

Cat. 100 Rev 001

2245 A Street, Santa Maria, CA 93455 USA


www.wascoinc.com
e-mail: sales@wascoinc.com
(805) 739-2747 * FAX (805) 739-2751

17
ISO9001:2008 Certified

Cat. 100 Rev 001

2245 A Street, Santa Maria, CA 93455 USA


www.wascoinc.com
e-mail: sales@wascoinc.com
(805) 739-2747 * FAX (805) 739-2751

DP30 Solid State Differential Pressure Switch

DV40 Solid State Differential Vacuum Switch

Technical Specifications
No.

Name

Activation Point Range

1.0 - 500 PSI

Activation Point Tolerance

See Table XVI

Temperature Range

Leak Rate

Weight

Technical Specifications

Requirements

No.

Name

Activation Point Range

2.0 - 29.5 inHg

Activation Point Tolerance

See Table XVII

0 F to + 150 F

Temperature Range

0 F to + 150 F

1.0 x 10 cc/min Air

Leak Rate

7.8 oz (typical with 12 inch W3 electrical interface)

Weight

RoHS compliant

-3

7.8 oz (typical with 12 inch W3 electrical interface)

Amp
Inductive

Contact
Material

Max. Amp Rating

115/28

1/1

250/28

5/5

250/28

7/7

1/0.5

Gold

5/3

Silver

7/4

Silver

Material Specifications DP30


Wetted

Non Wetted

Body/Fitting

300 Series Stainless


Steel

Electrical Interface

Steel (zinc chromate


finish)

Locking Compound

Loctite 277 (P1)

Lock Ring

Steel (zinc chromate


finish)

O-Ring

Buna N, other
compounds available

Sensor

17-7PH Stainless
Steel

Magnet

Neodymium, nickel
plated finish (P2)

Magnet Carrier

303 Stainless Steel

Spring

Stainless Steel (P2)

P2
P1

Pressure Switch Adjustment (if field adjustable)


This model may be adjusted by loosening the Lock Ring and turning the electric switch housing counter clockwise
to raise the activation point, clockwise to lower the activation point. Holding the electric switch housing in position,
tighten the Lock Ring and check the activation point. Repeat preceding adjustment instructions if necessary.

See page 20 for Solid State technical data regarding this switch

Operating Pressure Range and Standard Tolerances


Table XVI - Positive Pressure Activation Points DP30
Sensor

Max System
Pressure Differential*
(PSID)

Max Operating
Pressure (PSIG)

Activation Point
Range (PSID)

Activation Point
Tolerance () (PSID)

Reset Band
(PSID)

30

500

1 - 30

0.7

0.7 - 2.3

125

500

3 - 125

2.0

1.3 - 3.8

250

500

8 - 250

5.0

2.0 - 10.0

15

500

500

18 - 500

10.0

5.0 - 21.0

*Example: P1 at 107 PSI, P2 at 64, Pressure Differential = (107-64) = 43 PSID

Volts
AC/DC

Amp
Resistive

Amp
Inductive

115/28

1/1

1/0.5

Gold

250/28

5/5

5/3

Silver

250/28

7/7

7/4

Silver

Material Specifications DV40


Wetted

Cat. 100 Rev 001

2245 A Street, Santa Maria, CA 93455 USA


www.wascoinc.com
e-mail: sales@wascoinc.com
(805) 739-2747 * FAX (805) 739-2751

Non Wetted

Body/Fitting

300 Series Stainless


Steel

Electrical Interface

Steel (zinc chromate


finish)

Locking Compound

Loctite 277 (P1)

Lock Ring

Steel, (zinc chromate


finish)

O-Ring

Buna N, other
compounds available

Sensor

17-7PH Stainless
Steel

Magnet

Neodymium, nickel
plated finish (P2)

Magnet Carrier

303 Stainless Steel

Spring

Stainless Steel (P2)

P2
P1

Vacuum Switch Adjustment (if field adjustable)


This model may be adjusted by loosening the Lock Ring and turning the electric switch housing clockwise to raise
the activation point, counter clockwise to lower the activation point. Holding the electric switch housing in position,
tighten the Lock Ring and check the activation point. Repeat preceding adjustment instructions if necessary.

See page 20 for Solid State technical data regarding this switch

Operating Pressure Range and Standard Tolerances


Table XVII - Vacuum Activation Points DV40
Sensor

Max System
Pressure Differential*
(PSID)

Max Operating
Pressure (PSIG)

Activation Point
Range (inHg)

Activation Point
Tolerance () (inHg)

Reset Band
(inHg)

15

100

2.0 - 29.5

1.0

1.0 - 4.0

*Example: P1 at 12.0 inHg, P2 at 3.0 inHg, Pressure Differential = (12.0-3.0) = 9.0 inHg

Custom specifications available

Custom specifications available

18

Contact
Material

Solid State

Amp
Resistive

Solid State

Volts
AC/DC

ISO9001:2008 Certified

1.0 x 10-3 cc/min Air

Electrical Rating

Differential

Max. Amp Rating

RoHS compliant

19
ISO9001:2008 Certified

Cat. 100 Rev 001

2245 A Street, Santa Maria, CA 93455 USA


www.wascoinc.com
e-mail: sales@wascoinc.com
(805) 739-2747 * FAX (805) 739-2751

Differential

Electrical Rating

Requirements

Solid State Technical Data

Solid State High Pressure


RoHS compliant

HE 903 Series | 400 - 6,000 PSI RANGE | Burst 6,000 PSI

Features:

Stainless Steel Construction


Piston With O-Ring Style Sensor
Miniature Size
Excellent Accuracy and Repeatability
Mid-range/Field Adjustable, Factory
Calibrated, or Factory Calibrated & Locked

Sensor

Max. System
Pressure (PSI)

Activation Point
Range (PSI)

Activation Point
Tolerance (PSI)

Reset Band
(PSI)

Burst
Pressure (PSI)

3,000

400 - 3,000

4%

40 - 150

6,000

6,000

900 - 6,000

4%

50 - 350

6,000

Notes:All values given in PSI (gage).


Media type must accompany orders.

ELECTRONICS SPECIFICATION
INPUT VOLTAGE Vcc: +4.5 TO 24 VDC

INPUT CURRENT Icc: 9 MILLIAMPS MAX.



(OUTPUT VOLTAGE HI)
OUTPUT SATURATION VOLTAGE: 400 MILLIVOLTS MAX.
OUTPUT ON CURRENT

OUTPUT RISE TIME: 1 MICROSECOND


OUTPUT FALL TIME: 1 MICROSECOND
OUTPUT LEAKAGE CURRENT: 10 MICROAMPS
MAX. WHEN SWITCH IS NORMALLY OPEN: LOGIC IS HI
WHEN SWITCH IS CLOSED: LOGIC IS LO AT Activation

TEMPERATURE RANGE: 0 F to +160 F, a slight change up to 2% in the activation may occur below +40 F and above +125 F.

Solid State Low Pressure


HE 901 Series | 1 - 500 PSI RANGE
Features:

Stainless Steel Construction


Capsule Type Pressure Sensor
Miniature Size
Excellent Accuracy and Repeatability
Mid-range/Field Adjustable, Factory
Calibrated, or Factory Calibrated & Locked

Note: All values given in PSI (gage).

Stainless Steel Construction


Sensitive Limp Diaphragm Sensor
Miniature Size
Excellent Accuracy and Repeatability
Mid-range/Field Adjustable, Factory
Calibrated, or Factory Calibrated & Locked

Sensor

Max. System
Pressure (PSI)

6,000

2
3

Activation Point
Range (PSI)

Reset
Band (PSI)

Burst
Pressure (PSI)

500

3%

15 - 60

12,000

6,000

400 - 2,500

3%

20 - 200

12,000

6,000

1,500 - 6,000

3%

100 - 600

12,000

100 -

Pressure Switch Adjustment (if field adjustable)


A change in the activation may be made by turning the adjusting ring located in the opening in the side of the body.
Causing the ring to turn left will raise the activation point, and turning it right will lower it. For the best results after
resetting the switch, cycle the system pressure level several times to stabilize the new activation point. Repeat preceding
adjustment instructions if necessary.

Max. System
Pressure (PSI)

Activation Point
Range (PSI)

Activation Point
Tolerance (PSI)

Reset Band
(PSI)

30

1 - 30

0.7

0.7 - 2.5

125

3 - 125

2.0

1.2 - 3.5

250

8 - 250

5.0

2.0 - 10.0

15

500

18 - 500

10.0

5.0 - 20.0

RoHS compliant

HE 905 Series | 1.6 - 29.9 inHg RANGE


Features:

Stainless Steel Construction


Capsule Type Vacuum Sensor
Miniature Size
Excellent Accuracy and Repeatability
Mid-range/Field Adjustable, Factory
Calibrated, or Factory Calibrated & Locked

Max. System
Pressure (inHg)

Activation Point
Range (inHg)

Activation Point
Tolerance (inHg)

Reset Band
(inHg)

30.0

1.6 - 29.9

1.0

1.0 - 4.0

NOTE: The HE905 series vacuum switches may be damaged if exposed


to positive pressure

Wetted Materials:

Capsule - 17-7 PH Stainless Steel


O-Ring - Buna-N, other compounds available
Body - 300 Series Stainless Steel

RoHS compliant

Vacuum Switch Adjustment (if field adjustable)


This model may be adjusted by loosening the Lock Ring and turning the electric switch housing clockwise to raise the
activation point, counter clockwise to lower the activation point. Holding the electric switch housing in position, tighten the
Lock Ring and check the activation point. Repeat preceding adjustment instructions if necessary.

Stainless Steel Construction


Sensitive Limp Diaphragm Sensor
Miniature Size
Excellent Accuracy and Repeatability
Mid-range/Field Adjustable, Factory
Calibrated, or Factory Calibrated & Locked

UL 353 Recognized
</= 125 PSI

Sensor

Max. System
Pressure

Activation Point
Range (PSI)

Activation Point
Tolerance (PSI)

Reset Band
(PSI)

Burst Pressure
(PSI)

3,000

1 - 10

0.5

1.0 - 3.0

6,000

3,000

5 - 50

1.0

1.2 - 3.5

6,000

3,000

10 - 100

2.0

5.0 - 9.0

6,000

Note: All values given in PSI (gage).


Pressure Switch Adjustment (if field adjustable)
A change in the activation may be made by turning the adjusting ring located in the opening in the side of the body.
Causing the ring to turn left will raise the activation point, and turning it right will lower it. For the best results after
resetting the switch, cycle the system pressure level several times to stabilize the new activation point. Repeat preceding
adjustment instructions if necessary.

20
ISO9001:2008 Certified

Cat. 100 Rev 001

Wetted Materials:

Fitting - 300 Series Stainless Steel


O-Ring - Buna-N, other compounds available
Diaphragm - Kapton
Washer - 300 Series Stainless Steel
Screw - 300 Series Stainless Steel

2245 A Street, Santa Maria, CA 93455 USA


www.wascoinc.com
e-mail: sales@wascoinc.com
(805) 739-2747 * FAX (805) 739-2751

Stainless Steel Construction


Sensitive Limp Diaphragm Sensor
Miniature Size
Excellent Accuracy and Repeatability
Mid-range/Field Adjustable, Factory
Calibrated, or Factory Calibrated & Locked

Sensor

Max. System
Pressure (PSI)

1
2

Capsule - 17-7 PH Stainless Steel


O-Ring - Buna-N, other compounds available
Body - 300 Series Stainless Steel
Locking Compound - Loctite 277

UL 353 Recognized
</= 125 PSI

Activation Point
Range (inHg)

Activation Point
Tolerance (inHg)

Reset Band
(inHg)

Burst
Pressure (PSI)

3,000

1.0 - 5.0

0.3

0.5 - 2

6,000

3,000

2.0 - 29.9

0.5

1.0 - 3

6,000

Vacuum Switch Adjustment (if field adjustable)


A change in the activation may be made by turning the adjusting ring located in the opening in the side of the body.
Causing the ring to turn right will raise the activation point, and left will lower it. For the best results after resetting the
switch, cycle the system pressure level several times to stabilize the new activation point. Repeat preceding adjustment
instructions if necessary.

21
ISO9001:2008 Certified

Wetted Materials:

RoHS compliant

HE 906 Series | 1 - 29.9 inHg RANGE | Burst 6,000 PSI


Features:

UL 353 Recognized
</= 125 PSI

Sensor

Note: HE905 Series sensor will be damaged if positive pressure is applied

Features:

Wetted Materials:
Fitting - 300 Series Stainless Steel
O-Ring - Buna-N, other compounds available
Diaphragm - Kapton

Solid State Vacuum

Sensor

HE 902 Series | 1 - 100 PSI RANGE | Burst 6,000 PSI

UL 353 Recognized
</= 125 PSI

Activation Point
Tolerance (PSI)

Note:All values given in PSI (gage).

RoHS compliant

Pressure Switch Adjustment (if field adjustable)


This model may be adjusted by loosening the Lock Ring and turning the electric switch housing counter clockwise to raise
the activation point, clockwise to lower the activation point. Holding the electric switch housing in position, tighten the Lock
Ring and check the activation point. Repeat preceding adjustment instructions if necessary.

Piston - 17-4 Stainless Steel


O-Ring - Buna-N, other compounds available
Body - 300 Series Stainless Steel

RoHS compliant

HE 904 Series | 100 - 6,000 PSI RANGE | Burst 12,000 PSI


Features:

Wetted Materials:

Cat. 100 Rev 001

Wetted Materials:

Fitting - 300 Series Stainless Steel


O-Ring - Buna-N, other compounds available
Diaphragm - Kapton

2245 A Street, Santa Maria, CA 93455 USA


www.wascoinc.com
e-mail: sales@wascoinc.com
(805) 739-2747 * FAX (805) 739-2751

Solid State

OPTIONS ON ALL SOLID STATE SWITCHES:


REVERSE POLARITY PROTECTION
OUTPUT SHORT CIRCUIT PROTECTION
PNP OUTPUT CAPABILITY (NPN output is
standard)

Solid State

Pressure Switch Adjustment (if field adjustable)


This model may be adjusted by loosening the Lock Ring and turning the electric switch housing counter clockwise to raise
the activation point, clockwise to lower the activation point. Holding the electric switch housing in position, tighten the Lock
Ring and check the activation point. Repeat preceding adjustment instructions if necessary.

How to Order: Capsule Sensor Switches

How to Order: Overpressure Protected Switches

(P110, V110, P500, V500, P550, TP700, TV700 Series)

(P250, V250, P325, P400 Series)

P110
Switch
Series

-3
Sensor

W3

Max
Amperage

Interface

Activation
Adjustability

-X

/9999

Options
Callout

Application
Number

V250
Switch
Series

Switch Series

Switch Series

Sensor

Sensor

Amperage

Amperage

P110, V110, P500, V500, P550, TP700 or TV700

-3, -5, -8, -15 (see switch series specification sheet for individual pressure/vacuum range)

-X

/9999

Sensor

Amperage

Interface

Activation
Adjustability

Options
Callout

Application
Number

P250, V250, P325 or P400


-0, -1, -2, -3, -4, -5 (see switch series specification sheet for individual pressure/vacuum range)

Amp Resistive

Amp Inductive

Contact Material

Max. Amp Rating

Volts AC/DC1

Amp Resistive

Amp Inductive

Contact Material

115/28

1/1

1/0.5

Gold

115/28

1/1

1/0.5

Gold

250/28

5/5

5/3

Silver

250/28

5/5

5/3

Silver

250/28

7/7

7/4

Silver

250/28

7/7

7/4

Silver

W2 = 2 Jacketed Wire Leads (Standard)


W3 = 3 Jacketed Wire Leads (Standard)
F2 = 2 Screw Terminals (#8-32 screws)
F3 = 3 Screw Terminals (#8-32 screws)
Q2 = 2 1/4 Blade Terminals
Q3 = 3 1/4 Blade Terminals
A
B
C

Volts AC/DC1

L2 = 2 Unjacketed Wire Leads


L3 = 3 Unjacketed Wire Leads
S2 = 2 Solder Pins
S3 = 3 Solder Pins

Interface

Activation Adjustability



W3

Max. Amp Rating

Interface

-3

= Factory calibrated and field adjustable


= Factory calibrated and permanently locked
= Switch calibrated at the middle of its range and field adjustable (customer calibrates switch to final
activation)

W2 = 2 Jacketed Wire Leads (Standard)


W3 = 3 Jacketed Wire Leads (Standard)
F2 = 2 Screw Terminals (#8-32 screws)
F3 = 3 Screw Terminals (#8-32 screws)
Q2 = 2 1/4 Blade Terminals
Q3 = 3 1/4 Blade Terminals

Activation Adjustability



A
B
C

= Factory calibrated and field adjustable


= Factory calibrated and permanently locked
= Switch calibrated at the middle of its range and field adjustable (customer calibrates switch to final
activation)

Options Callout

Options Callout

Application Number

Application Number

Example: P110-31W3C-X/9999

Example: V250-31W3C-X/9999

-X = Special Options; this will only be inserted when your application calls for special options. On initial
order, include what X indicates following the part number; example (X= Electrical Connector Assembly).
Insert the four digit number (sometimes called file number) that Wasco has supplied to you. This number
identifies all the unique properties of your application. Note, this number is issued by the factory or your
distributor/representative. Do not insert anything other than what has been issued to you. If the requirements
for your application changes, check with Wasco to see if this four digit number needs to change.
This part number indicates that this is a (P110) series switch with a (-3) sensor (Maximum pressure of
30PSI) with an electrical switch max amperage of (1) amp. Interface is (W3) three Jacketed Wire Leads.
The switch is (C) calibrated at the middle of its range and field adjustable. (-X) Options callout indicated (for
this switch only) that a 9-Pin enclosure is included, (9999) is the Application Number Wasco has issued to
you.

22
ISO9001:2008 Certified

Cat. 100 Rev 001

2245 A Street, Santa Maria, CA 93455 USA


www.wascoinc.com
e-mail: sales@wascoinc.com
(805) 739-2747 * FAX (805) 739-2751

L2 = 2 Unjacketed Wire Leads


L3 = 3 Unjacketed Wire Leads
S2 = 2 Solder Pins
S3 = 3 Solder Pins

-X = Special Options; this will only be inserted when your application calls for special options. On initial
order, include what X indicates following the part number; example (X= Electrical Connector Assembly).
Insert the four digit number (sometimes called file number) that Wasco has supplied to you. This number
identifies all the unique properties of your application. Note, this number is issued by the factory or your
distributor/representative. Do not insert anything other than what has been issued to you. If the requirements
for your application changes, check with Wasco to see if this four digit number needs to change.
This part number indicates that this is a (V250) series switch with a (-3) sensor and an electrical switch
max amperage of (1) amp. Interface is (W3) three Jacketed Wire Leads. The switch is (C) calibrated at the
middle of its range and field adjustable (-X) Options callout indicated (for this switch only) that there is a
Stainless Steel enclosure. (9999) is the Application Number Wasco has issued to you.

23
ISO9001:2008 Certified

Cat. 100 Rev 001

2245 A Street, Santa Maria, CA 93455 USA


www.wascoinc.com
e-mail: sales@wascoinc.com
(805) 739-2747 * FAX (805) 739-2751

How to Order: High Purity Switches

How to Order: Differential Switches

(SP120, SV120, UHP150, UHP160)

(DP30, DV40 Series)

SP120
Switch
Series

Fitting

-3

Sensor

Max
Amperage

W3
Interface

-X

/9999

Activation
Adjustability

Options
Callout

Application
Number

Switch Series

4
7
0

= 1/4 NPT Male


= 7/16-20 UNF
= Custom Fittings

-3, -5, -8, -15 (see switch series specification sheet for individual pressure/vacuum range)

Max. Amp Rating

Volts AC/DC1

Amp Resistive

Amp Inductive

Contact Material

115/28

1/1

1/0.5

Gold

250/28

5/5

5/3

Silver

250/28

7/7

7/4

Silver

W2 = 2 Jacketed Wire Leads (Standard)


W3 = 3 Jacketed Wire Leads (Standard)
F2 = 2 Screw Terminals (# 8-32 screws)
F3 = 3 Screw Terminals (# 8-32 screws)
Q2 = 2 1/4 Blade Terminals
Q3 = 3 1/4 Blade Terminals
A
B
C

Sensor

Fitting
(P1)

Fitting
(P2)

Activation

Activation Activation
Indicator Adjustability

-X

/9999

Options
Callout

Application
Number

DP30, DV40
-3, -5, -8, -15 (see switch series specification sheet for individual pressure/vacuum range)

A
B
C
D

= Cartridge (7/8 - 14)


E = 1/4 Male VCR
= 1/4 tube with Swagelok Nut & Ferrule
F = M12 x 1.5 Male
= 1/8 NPT Male
G = 7/16 - 20 Male
= 1/4 NPT Male

Activation Indicator

For DP30 only


R = Activation is RISING presure
F = Activation is FALLING pressure
For DV40 only
H = Activation on increasing vacuum (measuring vacuum with inches of mercury (inHg))
J = Activation on decreasing vacuum (measuring vacuum with inches of mercury (inHg))
K = Activation on decreasing Torr (incr vacuum), where 760 Torr = atmosphere and 0 Torr = perfect vacuum
L = Activation on increasing Torr (decr vacuum), where 760 Torr = atmosphere and 0 Torr = perfect vacuum

Activation Adjustability

= Factory calibrated and field adjustable


= Factory calibrated and permanently locked
= Switch calibrated at the middle of its range and field adjustable (customer calibrates switch to final
activation)

Options Callout

-X = Special Options; this will only be inserted when your application calls for special options. On initial
order, include what X indicates following the part number; example (X= Electrical Connector Assembly).

Application Number

Insert the four digit number (sometimes called file number) that Wasco has supplied to you. This number identifies all the unique
properties of your application. Note, this number is issued by the factory or your distributor/representative. Do not insert anything other
than what has been issued to you. If the requirements for your application changes, check with Wasco to see if this four digit number
needs to change.

Example: SP120-31W3C-X/9999

This part number indicates that this is a (SP120) series switch with a (-3) sensor (Maximum pressure of 30PSI) with an electrical
switch max amperage of (1) amp. Interface is (W3) three Jacketed Wire Leads. The switch is (A) Factory set and field adjustable. (-X)
Options callout indicated (for this switch only) that there is a Stainless Steel enclosure. (9999) is the Application Number Wasco has
issued to you.

24
ISO9001:2008 Certified

Using a three digit number, insert what your desired Activation (in psid) is. For a mid-range Activation,
insert MDR

L2 = 2 Unjacketed Wire Leads


L3 = 3 Unjacketed Wire Leads
S2 = 2 Solder Pins
S3 = 3 Solder Pins

Activation Adjustability



080

Activation

Interface

Fitting (P1) & (P2) Select one of the following for each fitting. See page 20? for optional fittings.

Switch Series

8 = 1/8 NPT Male


9 = 1/4 Face Seal

Amperage

-5

Sensor

Sensor

Switch
Series

SP120, SV120, UHP150 or UHP160

Fitting

DP30

Cat. 100 Rev 001

2245 A Street, Santa Maria, CA 93455 USA


www.wascoinc.com
e-mail: sales@wascoinc.com
(805) 739-2747 * FAX (805) 739-2751

A
B
C

= Factory calibrated and field adjustable


= Factory calibrated and permanently locked
= Switch calibrated at the middle of its range and field adjustable (customer calibrates switch to final
activation)

Options Callout

-X = Special Options; this will only be inserted when your application calls for special options. On initial
order, include what X indicates following the part number; example (X= Electrical Connector Assembly).

Application Number

Insert the four digit number (sometimes called file number) that Wasco has supplied to you. This number identifies all the unique
properties of your application. Note, this number is issued by the factory or your distributor/representative. Do not insert anything other
than what has been issued to you. If the requirements for your application changes, check with Wasco to see if this four digit number
needs to change.

Example: DP30-05BB080RA-X/9999

This part number indicates that this is a (DP30) series switch with a (-5) sensor (Maximum pressure of 125 PSID). P1 fitting is (B) 1/4
tube with Swagelok Nut & Ferrule; P2 fitting is also a (B) 1/4 tube with Swagelok Nut & Ferrule. The Activation is (080) 80 PSID
on (R) RISING pressure, the switch is (A) Factory set and field adjustable. (-X) Options callout indicated (for this switch only) that
the switch includes a BX1-1 enclosure (see page 20 of this catalog for optional enclosure information). (9999) is the unique four digit
Application number issued to you.

25
ISO9001:2008 Certified

Cat. 100 Rev 001

2245 A Street, Santa Maria, CA 93455 USA


www.wascoinc.com
e-mail: sales@wascoinc.com
(805) 739-2747 * FAX (805) 739-2751

Electrical Switch Characteristics

How to Order: Solid State Switches


(Solid State Series)

HE901
Switch
Series

-3

Sensor

Fitting

Activation
Adjustability

-X
Options
Callout

/9999

Max. Amp Rating


1
5
7

Amp Resistive
1/1
5/5
7/7

Amp Inductive
1/0.5
5/3
7/4

Contact material
Gold
Silver
SIlver

Application
Number

Standard & Optional Electrical Interfaces

Switch Series

Volts AC/DC
115/28
250/28
250/28

HE901, HE902, HE903, HE904, HE905 or HE906

Sensor

-1, -2, -3, -4, -5, -8, -15 (see switch series specification sheet for individual pressure/vacuum range)

Fitting




4
7
8
9
0

= 1/4 NPT Male


= 7/16-20 UNF
= 1/8 NPT Male
= 1/4 Face Seal
= Custom Fittings

F2

A
B
C

Q2

2 Terminals
3 Terminals
Potted with #8-32 screws.

Activation Adjustability



F3

Screw Terminals

= Factory calibrated and field adjustable


= Factory calibrated and permanently locked
= Switch calibrated at the middle of its range and field adjustable (customer calibrates switch to final
activation)

Options Callout

Q3

Quick-Connect

Application Number

Example: HE901-30C-X/9999

Switch Set Point Setting Options


A = Factory set and field adjustable
B = Factory set and permanately locked
C = Set mid-range and field adjustable,
customer to set final set point

Insert the four digit number (sometimes called file number) that Wasco has supplied to you. This number
identifies all the unique properties of your application. Note, this number is issued by the factory or your
distributor/representative. Do not insert anything other than what has been issued to you. If the requirements
for your application changes, check with Wasco to see if this four digit number needs to change. This
number is used as a revision control.
This part number indicates that this is a (HE901) series switch with a (-3) sensor (Maximum pressure of
30PSI.) The switch is (C) set at the middle of its range and is field adjustable. (-X) Options callout indicated
(for this switch only) that a BX1-3 Enclosure has been added. (9999) is the Application Number Wasco has
issued to you.

Interface

Solid State switches come with a three lead, electrically shielded jacketed wire with a fourth grounding wire.

W3

Jacketed Wires
(standard interface)

L2

L3

Flying Wire Leads

S2

S3

Solder Pins

2 Terminals
3 Terminals
2 Terminals
3 Terminals
2 Terminals 3 Terminals
Potted, standard terminals
Potted, low profile style,
Potted with .060 dia. pins.
2 Terminals
3 Terminals
that accept the ark-les or
flying leads only, Standard Also accepts AMP #60789-2
Potted to full height for strain
equal female terminals.
#20 AWG x 12long. Polyvinyl
PIN receptacles.
relief. Standard #20 AWG
chloride insulated.
x 12 long jacketed wire.
Polyvinyl chloride insulated.

Important: If your choice of electrical


interface is other than W3, replace the
W# with the style of your choice. (i.e.
P110-31-W3A becomes P110-31-F2A)

-X = Special Options; this will only be inserted when your application calls for special options. On initial
order, include what X indicates following the part number; example (X= Electrical Connector Assembly).

W2

Wire Color Code


Pressure Switch

Common - Black

Normally Open (NO) - White

Normally Closed (NC) - Red
Vacuum Switch

Common - Black

Normally Open (NO) - Red

Normally Closed (NC) - White

Available Options and Special Modifications


To modify a part, add -X at the end of the part number. A full description must accompany your order.
If our standard line of switches does not meet your special requirements, please consult our Sales Department. We understand your needs in special situations when a standard product will not do the job. We will be glad to review your special
requirements and advise you accordingly
Let Wasco eliminate your final assembly. We can save you time by offering a wide variety of pin and connector assemblies
for our switches. We utilize AMP, Molex, Cannon, Burndy, Hirschmann, Packard, Bendix, and other connector suppliers.
We have a certified class 100 cleanroom for manufacturing and welding. Other diaphragm materials are available such as
Kalrez (tm), Teflon (tm) or Stainless Steel.

26
ISO9001:2008 Certified

Cat. 100 Rev 001

2245 A Street, Santa Maria, CA 93455 USA


www.wascoinc.com
e-mail: sales@wascoinc.com
(805) 739-2747 * FAX (805) 739-2751

27
ISO9001:2008 Certified

Cat. 100 Rev 001

2245 A Street, Santa Maria, CA 93455 USA


www.wascoinc.com
e-mail: sales@wascoinc.com
(805) 739-2747 * FAX (805) 739-2751

Standard Process Fittings


4

1/4 NPT Male

7/16-20 UNF

Enclosures
All enclosures are factory installed only, and are usually installed on switches that are factory set and locked (option B
under the Activation Adjustability category.) This will assure protection to the equivalent minimum level of NEMA 4 or IP 65.

1/8 NPT Male

BX1 Series Enclosures

BX1 Series Enclosures (except


BX1-2X) come standard with 20
AWG x 18 long jacketed wire.

1/4 Face Seal

Custom Process Fittings

BX1-1

BX1-3

BX1
NPT Female

1 1/2 Surface
Mount

NPT Female

1 1/8 Surface
Mount

BX1-2

BX1 Series Enclosure Material:


Body - 300 Series Stainless Steel
Strain Relief - (BX1-3) nylon with
BUNA-N gasket/gland

BX1-2X
BX1-2X terminal pin-out
#1 pole - Normally open
#2 pole - Normally closed
Ground pole - common

BX1-3
BX1-3 Includes Heyco
Liquid tight pigtail fitting
with strain relief.

Custom Enclosures

KF-16

1/4 Tube

M12 x 1.5

Your
fitting
here
5/16-24 UNF

KF-25

28
ISO9001:2008 Certified

Cat. 100 Rev 001

Additional Fittings
Available

2245 A Street, Santa Maria, CA 93455 USA


www.wascoinc.com
e-mail: sales@wascoinc.com
(805) 739-2747 * FAX (805) 739-2751

9-Pin Enclosure

Cannon 3-Pin
Connector

Applicable Switch Models:


P/V110, P/V250, P325, P400, SP/SV120, UHP150,
UHP160, HE901-906, DP30, and DV40 series.

ISO9001:2008 Certified

Material:
Body - 300 Series Stainless Steel

29

Cat. 100 Rev 001

2245 A Street, Santa Maria, CA 93455 USA


www.wascoinc.com
e-mail: sales@wascoinc.com
(805) 739-2747 * FAX (805) 739-2751

Glossary of Terms

Activation Point: The point at which a sensor changes mechanical or electrical output state as a result of change to its input. Sometimes referred to as
Cut-in. (i.e. the pressure at which a switch will change from OFF to ON) See also: Deactivation Point, Activation Point.
Auto Reset: Automatic Reset switches, which are the most common type, will change the state of the electrical poles (cut-in/cut-out) when the pressure
crosses the activation point (Activation Point). The electrical state will return to the previous state when the pressure crosses the deactivation point. These
switches do not need human interaction to operate.
Burst Pressure: Pressure which causes failure of pressure sensing element. Exceeding the burst pressure results in permanent damage and mechanical
breach of process media.
Deadband: The difference in pressure between the activation point (Activation Point) and deactivation point (Reset Point). See also: hysteresis.
Deactivation Point: The point at which a sensor changes mechanical or electrical output state as a result of change to its input. Sometimes referred to as
Cut-out. (i.e. the pressure at which a switch will change from ON to OFF) See also: Activation Point, Activation Point.
Dielectric Strength: The maximum electric field strength that an insulator can withstand intrinsically without breaking down, i.e., without experiencing
failure of its insulating properties.
Helium Leak Tested:
Hysteresis: The difference in readings of an instrument when the value of the measured quantity is approached from two different directions.
IP 65: Product is totally protected from dust and protected against low pressure jets of water from all directions - limited ingress permitted.
Maximum Operating Pressure: The designed safe pressure limit of a sensing element at which regular use will cause no damage.
Maximum Operating Temperature: The designed safe temperature below which a sensor may be operated without loss of accuracy or integrity.
NEMA 4: Water-tight and dust-tight enclosures intended for use indoors or outdoors to protect the equipment against splashing, falling, or hose directed
water, external condensation and water seepage. They are also sleet-resistant.
Operating Pressure Range: The pressure range (minimum and maximum pressure) in which a sensor can be safely operated and maintain actuation
point and mechanical integrity.
Proof Pressure: Pressure exceeding the Maximum Operating Pressure to which a sensor may be occasionally subjected to and cause no mechanical
loss of integrity.
Repeatability: The exactness with which a sensor duplicates its Activation Point after successive cycles within the same operating conditions.
Reset Band: The difference in pressure between the activation point (Activation Point) and deactivation point (reActivation Point). See also: hysteresis.
Reset Point: Point at which a switch will return to its original or normal operating position.
Sensor: A primary measuring device (bellows, diaphragm, piston) for detecting either the absolute or variable pressure.
Set Point: The calibrated point at which a sensor will activate. Activation Point can be specified including the intended direction of pressure change
(increasing or decreasing) to account for hysteresis.
Set Point Tolerance: The range expressing the largest variation of activation of a sensor while operating within the listed operating conditions.
SPDT: An acronym meaning Single Pole Double Throw, referring to an electrical switch contain common, normally open and normally closed terminals.
See also: SPST.
SPST: An acronym meaning Single Pole Single Throw, referring to an electrical switch containing a common terminal and either a normally open or a
normally closed terminal. See also: SPDT
Vacuum Pressure: The range of pressure identified as below atmospheric pressure.
Wetted Parts: Sensor components that come into direct contact with the process media.

Return Policy
Should one of our products be suspected of malfunction, return it as soon as possible, with shipping charges prepaid. An RMA (Return Material Authorization)
number must be issued for your return. Please do not attempt to disassemble or repair as this action may destroy evidence of malfunction. Your cooperation
in this regard will save both time and money.

Warranty Policy
WASCO warrants the differential, pressure and vacuum switch products in this catalog to be free from defects in material and workmanship in normal use
and service for a period of 3 years or 1,000,000 cycles from date of shipment, which ever occurs first. This warranty is limited to the repair or replacement
of the product or part thereof which the Sellers inspection finds to be defective. This warranty shall not apply if the product has been subjected to misuse,
negligence, accident, modification or repair by unauthorized persons. Repairs NOT covered under this Warranty will be subjected to a standard service
charge. No other warranty or guarantee is expressed or implied.
Note: Please consider all the possible failure modes in your system that could occur with the use of our product. The switch you are considering could fail
mechanically or electrically and the user must bear full responsibility for its misapplication and misuse, including but not limited to any losses or damages
caused by your use of that switch in your products, and by your customers use of your products. Wasco, Inc. accepts no responsibility or liability for failures
resulting from any misapplication of its product.
Disclaimer: Precautions have been taken to assure accuracy of the information in this catalog. Wasco is not responsible for any typographic or pictorial errors. Product
dimensions in this catalog are nominal and are provided for the convenience of our customers. Wasco reserves the right to make product changes from time to time, without prior
notification, which may change the dimensions shown. We therefore recommend they be checked before using for customer projects or product development and specification.
The designs and dimensions of the products listed in this catalog were correct at the date of publication and are subject to change without notice.

30
ISO9001:2008 Certified

Cat. 100 Rev 001

2245 A Street, Santa Maria, CA 93455 USA


www.wascoinc.com