Professional Documents
Culture Documents
505
Nokia Flexi WCDMA Base Station, Rel. Flexi
WBTS4.0, Product Documentation, v.1
DN70305645
Issue 2-0 en
17/10/2007
1 (97)
Installing Flexi WCDMA BTS Modules for Stack, Wall, and Pole
Configurations
The information in this document is subject to change without notice and describes only the
product defined in the introduction of this documentation. This documentation is intended for the
use of Nokia Siemens Networks customers only for the purposes of the agreement under which
the document is submitted, and no part of it may be used, reproduced, modified or transmitted in
any form or means without the prior written permission of Nokia Siemens Networks. The
documentation has been prepared to be used by professional and properly trained personnel,
and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes
customer comments as part of the process of continuous development and improvement of the
documentation.
The information or statements given in this documentation concerning the suitability, capacity, or
performance of the mentioned hardware or software products are given as is and all liability
arising in connection with such hardware or software products shall be defined conclusively and
finally in a separate agreement between Nokia Siemens Networks and the customer. However,
Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions
contained in the document are adequate and free of material errors and omissions. Nokia
Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which
may not be covered by the document.
Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO
EVENT WILL NOKIA SIEMENS NETWORKS BE LIABLE FOR ERRORS IN THIS
DOCUMENTATION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL,
DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT
NOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS
OPPORTUNITY OR DATA, THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE
INFORMATION IN IT.
This documentation and the product it describes are considered protected by copyrights and
other intellectual property rights according to the applicable laws.
The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark of
Nokia Corporation. Siemens is a registered trademark of Siemens AG.
Other product names mentioned in this document may be trademarks of their respective owners,
and they are mentioned for identification purposes only.
Copyright Nokia Siemens Networks 2007. All rights reserved.
2 (97)
DN70305645
Issue 2-0 en
17/10/2007
Contents
Contents
Contents 3
1
7
7.1
7.2
9
9.1
9.2
10
10.1
10.2
11
12
12.1
12.2
13
Appendix
A.1
A.2
A.3
A.4
A.5
A.6
A Contents of
Contents of the
Contents of the
Contents of the
Contents of the
Contents of the
Contents of the
deliveries 79
System Module delivery 79
RF Module delivery 80
mounting kit for floor, wall and pole (FMFA) delivery
pole mounting kit delivery (optional) 82
transmission sub-module deliveries 83
transmission cable deliveries 89
81
DN70305645
Issue 2-0 en
17/10/2007
3 (97)
Installing Flexi WCDMA BTS Modules for Stack, Wall, and Pole
Configurations
4 (97)
DN70305645
Issue 2-0 en
17/10/2007
DN70305645
Issue 2-0 en
17/10/2007
5 (97)
Installing Flexi WCDMA BTS Modules for Stack, Wall, and Pole
Configurations
6 (97)
DN70305645
Issue 2-0 en
17/10/2007
Caution
Electrostatic discharge (ESD) may damage the modules. Wear an ESD
wrist strap or use a corresponding method when handling the modules.
to ESD stud
Wrist strap
DN7050727
Figure 1.
DN70305645
Issue 2-0 en
17/10/2007
7 (97)
Installing Flexi WCDMA BTS Modules for Stack, Wall, and Pole
Configurations
Summary
Unpack and check the delivery carefully before the installation to make
sure that all the required items are available and undamaged.
Steps
8 (97)
1.
2.
3.
4.
5.
DN70305645
Issue 2-0 en
17/10/2007
Steps
DN70305645
Issue 2-0 en
17/10/2007
1.
2.
3.
4.
5.
6.
7.
8.
9 (97)
Installing Flexi WCDMA BTS Modules for Stack, Wall, and Pole
Configurations
10 (97)
DN70305645
Issue 2-0 en
17/10/2007
DN7050715
Figure 2.
DN70305645
Issue 2-0 en
17/10/2007
11 (97)
Installing Flexi WCDMA BTS Modules for Stack, Wall, and Pole
Configurations
Steps
1.
12 (97)
2.
3.
Fix the two external cable entries with two screws each.
DN70305645
Issue 2-0 en
17/10/2007
The plinth can be lifted and mounted first and then each module
lifted separately. When lifting a single module, a lifting bag must be
used.
Warning
The equipment is heavy. Take care when lifting it.
Caution
The rear stopper is fragile. Do not attempt to lift the plinth using the rear
stopper.
DN70305645
Issue 2-0 en
17/10/2007
13 (97)
Installing Flexi WCDMA BTS Modules for Stack, Wall, and Pole
Configurations
Caution
The cable support plates on the sides of the module casings are fragile.
Do not attempt to lift the module casing using the cable support plates.
Steps
1.
Attach the lifting eye bolts to the attachment points in the plinth.
Lifting eye bolts (M12) are not included in the delivery. You can order
the LEKA kit separately from your Nokia supplier.
2.
Attach the hoisting belt or the rope to the lifting eye bolts.
Attach the hoisting belt or rope so that the angle between the belt or
rope and the plinth is minimum 60. The distance between the plinth
and the belt or rope is minimum 400 mm.
14 (97)
DN70305645
Issue 2-0 en
17/10/2007
60
400 mm
DN7096814
Figure 3.
DN70305645
Issue 2-0 en
17/10/2007
3.
4.
5.
15 (97)
Installing Flexi WCDMA BTS Modules for Stack, Wall, and Pole
Configurations
16 (97)
DN70305645
Issue 2-0 en
17/10/2007
Note
When modules are installed inside a cabinet, no separate earthing
(grounding) cable for the modules is required. The cabinet provides
adequate earthing (grounding).
Note
If the base transceiver station (BTS) has more than one plinth, connect
the main earth (ground) to one of the plinths and earth (ground) all the
modules to that plinth. Alternatively, earth (ground) the modules to their
own plinths and then connect the plinths to the main earth (ground).
DN70305645
Issue 2-0 en
17/10/2007
17 (97)
Installing Flexi WCDMA BTS Modules for Stack, Wall, and Pole
Configurations
Summary
System Module
cable entry
2
3
6
RF Module
cable entry
1
AC/DC power module
grounding
Modules grounding
points
DN7037752
Figure 4.
Steps
18 (97)
1.
2.
3.
4.
Connect the other end of the cable to the grounding point in the
plinth.
5.
DN70305645
Issue 2-0 en
17/10/2007
6.
DN70305645
Issue 2-0 en
17/10/2007
Fix the excess cables to the cable support plates with cable
ties.
19 (97)
Installing Flexi WCDMA BTS Modules for Stack, Wall, and Pole
Configurations
20 (97)
DN70305645
Issue 2-0 en
17/10/2007
7
7.1
When choosing the location for the plinth, take into consideration the
required maintenance space. See figure Anchoring plinth on base
with maintenance space in the back for details.
If there are more than five modules in a stack, side access to the
back is needed for back maintenance.
See the following figures for clearances and Earthquake Zones 2
and 4 mounting holes.
DN70305645
Issue 2-0 en
17/10/2007
21 (97)
Installing Flexi WCDMA BTS Modules for Stack, Wall, and Pole
Configurations
Mounting holes
Plinth
Mounting holes
(Earthquake
Zone 2 & 4)
(Earthquake
Zone 2 & 4)
Front
Cover
Facility wall
75 mm
(3.0 in.)
13.5 mm
(0.5 in.)
(4 pcs)
75 mm
(3.0 in.)
360 mm
(14.1 in.)
145 mm
(5.7 in.)
300 mm
(11.8 in.)
DN70131327
Figure 5.
22 (97)
DN70305645
Issue 2-0 en
17/10/2007
Facility wall
Fan maintenance
space
305 mm (12 in.)
13.5 mm
(0.5 in.)
(4 pcs)
75 mm
(3.0 in.)
75 mm
(3.0 in.)
360 mm
(14.1 in.)
Plinth
300 mm
(11.8 in.)
DN7038966
Figure 6.
Steps
DN70305645
Issue 2-0 en
17/10/2007
1.
2.
23 (97)
Installing Flexi WCDMA BTS Modules for Stack, Wall, and Pole
Configurations
DN7038954
Figure 7.
3.
Note
The plinth must be fixed to the floor to meet the Earthquake Zone 4
requirement.
Further information
Next, ground the plinth to the site main ground. For more information, see
Grounding principle of the stand-alone BTS.
24 (97)
DN70305645
Issue 2-0 en
17/10/2007
7.2
Tip
The four module fixing screws between the module core and the
module casing must be tightened to 5 Nm.
If you are going to install Flexi Power Module (FPMA), its recommended
position is at the bottom of the module stack. For more information on
FPMA installation, see Installing Flexi Power Module (FPMA).
Tip
Connect the DC input cable and install the transmission sub-module
before the System Module installation.
DN70305645
Issue 2-0 en
17/10/2007
25 (97)
Installing Flexi WCDMA BTS Modules for Stack, Wall, and Pole
Configurations
System extension
module (optional)
RF Module
RF Module
Transmission
sub-module
System Module
RF Module
Power Module
(optional)
Plinth
DN7038978
Figure 8.
Summary
26 (97)
DN70305645
Issue 2-0 en
17/10/2007
3
1
DN7037667
Figure 9.
DN70305645
Issue 2-0 en
17/10/2007
27 (97)
Installing Flexi WCDMA BTS Modules for Stack, Wall, and Pole
Configurations
Steps
1.
Align the holes on the first module bottom with the fixing studs
on the plinth.
Tip
Line up the locating marks on the side of the module to help aligning the
holes with fixing studs.
2.
Align the module markings and push the module back until it
stops.
3.
4.
5.
Align the holes on the second module bottom with the fixing
studs on the first module.
6.
7.
8.
9.
Expected outcome
The following figure illustrates an example of the basic configuration of one
System Module and three RF Modules installed on the floor.
28 (97)
DN70305645
Issue 2-0 en
17/10/2007
DN7037655
Figure 10.
DN70305645
Issue 2-0 en
17/10/2007
29 (97)
Installing Flexi WCDMA BTS Modules for Stack, Wall, and Pole
Configurations
30 (97)
DN70305645
Issue 2-0 en
17/10/2007
DN70305645
Issue 2-0 en
17/10/2007
31 (97)
Installing Flexi WCDMA BTS Modules for Stack, Wall, and Pole
Configurations
Summary
thread locking compound
Bottom
Torque value: 10 Nm
DN7037043
Figure 11.
32 (97)
DN70305645
Issue 2-0 en
17/10/2007
Bottom
Torque value: 10 Nm
DN70102874
Figure 12.
Tip
Right-hand installation is the recommended installation option.
DN70305645
Issue 2-0 en
17/10/2007
33 (97)
Installing Flexi WCDMA BTS Modules for Stack, Wall, and Pole
Configurations
Steps
1.
DN70319067
Warning
Risk of physical injury. Secure the screws with a thread-locking
compound in pole and wall installations.
34 (97)
DN70305645
Issue 2-0 en
17/10/2007
2.
DN70305645
Issue 2-0 en
17/10/2007
35 (97)
Installing Flexi WCDMA BTS Modules for Stack, Wall, and Pole
Configurations
36 (97)
DN70305645
Issue 2-0 en
17/10/2007
9
9.1
DN70305645
Issue 2-0 en
17/10/2007
37 (97)
Installing Flexi WCDMA BTS Modules for Stack, Wall, and Pole
Configurations
185 mm
482,5 mm
DN7037067
Figure 13.
38 (97)
DN70305645
Issue 2-0 en
17/10/2007
Steps
1.
Mark the mounting screw locations on the wall and drill the
holes for the screws.
2.
Fix the upper mounting screws to the wall, lift the plinth on the
wall and fit it to the mounting screws.
Check that the plinth is level.
3.
4.
5.
6.
7.
In case you are installing more than one plinth, repeat steps 1-6
for each plinth.
Note that the required space between the plinths is 100 mm.
DN70305645
Issue 2-0 en
17/10/2007
39 (97)
Installing Flexi WCDMA BTS Modules for Stack, Wall, and Pole
Configurations
DN7047057
Figure 14.
Further information
Next, ground the plinth to the site main ground. For more information, see
Grounding principle of the stand-alone BTS .
40 (97)
DN70305645
Issue 2-0 en
17/10/2007
9.2
Note
To meet the earthquake requirement Telcordia GR-63-CORE and the
vibrational requirements for Earthquake Zone 4, the four module fixing
screws between the module core and the module casing must be
tightened to 5 Nm.
DN70305645
Issue 2-0 en
17/10/2007
41 (97)
Installing Flexi WCDMA BTS Modules for Stack, Wall, and Pole
Configurations
Wall
RF Module
Plinth
System Module
Power Module
(optional)
RF Module
RF Module
DN7055446
Figure 15.
42 (97)
DN70305645
Issue 2-0 en
17/10/2007
Summary
Caution
Excess torsion damages the casings. In wall and pole installation, do
not install more than two modules per plinth.
Caution
Incorrect installation may lead to damage to the modules. The modules
must be installed with the front panels facing left or right. Do not install
the modules with the front panels facing up or down.
DN70360702
DN70305645
Issue 2-0 en
17/10/2007
43 (97)
Installing Flexi WCDMA BTS Modules for Stack, Wall, and Pole
Configurations
Line up the
locating marks
1
3
Line up the
locating marks
5
7
8
DN7037079
Figure 16.
44 (97)
DN70305645
Issue 2-0 en
17/10/2007
Steps
1.
Align the holes on the first module's bottom with the fixing
studs on the plinth.
Tip
Line up the locating marks on the side of the module to help aligning the
holes with fixing studs.
2.
3.
4.
5.
Align the holes on the second module's bottom with the fixing
studs on the first module.
6.
7.
8.
9.
DN70305645
Issue 2-0 en
17/10/2007
45 (97)
Installing Flexi WCDMA BTS Modules for Stack, Wall, and Pole
Configurations
DN70144135
Figure 17.
10.
46 (97)
DN70305645
Issue 2-0 en
17/10/2007
Expected outcome
The following figure illustrates one example of the basic configuration of
one System Module and three RF Modules installed on the wall. The
installation in the figure is a right-hand installation, but the BTS can also be
installed as a left-hand installation.
Tip
Right-hand installation is recommended.
DN70305645
Issue 2-0 en
17/10/2007
47 (97)
Installing Flexi WCDMA BTS Modules for Stack, Wall, and Pole
Configurations
min 100 mm
(3.9 in.)
DN7037094
Figure 18.
48 (97)
DN70305645
Issue 2-0 en
17/10/2007
10
10.1
There are three different lengths of bolts available and four places for the
bolts in the pole mounting brackets. When attaching the brackets to the
pole, use the shortest possible bolts and the holes whose distance is the
closest to the pole diameter. See the following table and figure for more
details.
Table 1.
DN70305645
Issue 2-0 en
17/10/2007
Pole diameter
Bolt length
Hole number*
Torque value
60-90 mm
120 mm
29 Nm
95 - 125 mm
120 mm
29 Nm
126 - 165
200 mm
29 Nm
49 (97)
Installing Flexi WCDMA BTS Modules for Stack, Wall, and Pole
Configurations
Table 1.
Pole diameter
Bolt length
Hole number*
Torque value
166 - 210
200 mm
29 Nm
211 - 255
300 mm
29 Nm
256 - 300
300 mm
29 Nm
DN7038015
Figure 19.
Summary
50 (97)
DN70305645
Issue 2-0 en
17/10/2007
1
2
4
3
7
5
6
tighten the screws
DN7037101
Figure 20.
DN70305645
Issue 2-0 en
17/10/2007
51 (97)
Installing Flexi WCDMA BTS Modules for Stack, Wall, and Pole
Configurations
Steps
1.
Fix the upper pole mounting bracket on the pole and attach the
mounting screws on the bracket.
Make sure that the mounting screws in the upper pole mounting
bracket are on the lower edge of the bracket. Attach the screws
loosely at this point.
2.
Fix one half (the one with threads) of the lower pole mounting
bracket on the plinth adapter mechanics with the mounting
screws.
Make sure that the mounting screws in the lower pole mounting
bracket are in the upper edge of the bracket.
3.
Lift the plinth on the pole and fit it to the pole mounting
bracket's mounting screws.
See Lifting the stand-alone BTS for lifting instructions.
4.
5.
6.
Make sure that the pole mounting brackets are aligned and the
plinth is not twisted.
When the plinth is in a correct position, tighten the three screws in
the lower bracket of the adapter mechanics.
7.
52 (97)
DN70305645
Issue 2-0 en
17/10/2007
Further information
Next, ground the plinth to the site main ground. See Grounding principle of
the stand-alone BTS.
10.2
Note
To meet the earthquake requirement for Zone 4, the four module fixing
screws between the module core and the module casing must be
tightened to 5 Nm.
Tip
Perform the installation as completely as possible before lifting the
modules especially when installing the BTS to a high location.
DN70305645
Issue 2-0 en
17/10/2007
53 (97)
Installing Flexi WCDMA BTS Modules for Stack, Wall, and Pole
Configurations
Pole
RF Module
Plinth
System Module
RF Module
Power Module
(optional)
RF Module
Plinth
DN7056336
Figure 21.
54 (97)
DN70305645
Issue 2-0 en
17/10/2007
Summary
Caution
Excess torsion damages the casings. In wall and pole installation, do
not install more than two modules per plinth.
Caution
Incorrect installation may lead to damage to the modules. The modules
must be installed with the front panels facing left or right. Do not install
the modules with the front panels facing up or down.
Line up the
locating marks
Line up the
locating marks
4
3
DN7037113
DN70305645
Issue 2-0 en
17/10/2007
55 (97)
Installing Flexi WCDMA BTS Modules for Stack, Wall, and Pole
Configurations
Line up the
locating
marks
10
8
DN7056721
Figure 22.
Steps
1.
Align the holes on the first module's bottom with the fixing
studs on the plinth.
Tip
Line up the locating marks on the side of the module to help aligning the
holes with fixing studs.
2.
3.
Attach the module casing to the plinth with screws and spring
washers.
Secure with thread locking compound.
56 (97)
DN70305645
Issue 2-0 en
17/10/2007
4.
5.
Align the holes on the second module's bottom with the fixing
studs on the first module.
Tip
Line up the locating marks on the side of the module to help aligning the
holes with fixing studs.
6.
7.
8.
9.
DN70305645
Issue 2-0 en
17/10/2007
57 (97)
Installing Flexi WCDMA BTS Modules for Stack, Wall, and Pole
Configurations
DN70144135
Figure 23.
10.
58 (97)
DN70305645
Issue 2-0 en
17/10/2007
Expected outcome
The following figure illustrates an example of the basic configuration of one
System Module and three RF Modules installed on a pole. The installation
in the figure is a right-hand installation, however, the BTS can also be
installed as a left-hand installation.
DN7037125
Figure 24.
DN70305645
Issue 2-0 en
17/10/2007
59 (97)
Installing Flexi WCDMA BTS Modules for Stack, Wall, and Pole
Configurations
60 (97)
DN70305645
Issue 2-0 en
17/10/2007
11
DN70305645
Issue 2-0 en
17/10/2007
61 (97)
Installing Flexi WCDMA BTS Modules for Stack, Wall, and Pole
Configurations
3
1
Figure 25.
Steps
1.
62 (97)
DN70305645
Issue 2-0 en
17/10/2007
2.
3.
4.
5.
6.
7.
8.
9.
10.
Table 2.
Accepted GE SFPs
Code
Product
Manufacturer ID
Manufacturer's type
4808666
Finisar
FCLF-8521-3
4807974
Finisar
FTLF1319P1BTL
no MCOMPO SFP
Finisar
FTLF8519P2BTL
.
.
DN70305645
Issue 2-0 en
17/10/2007
63 (97)
Installing Flexi WCDMA BTS Modules for Stack, Wall, and Pole
Configurations
The SFP transceiver is optional for the FTIA and FTJA, and
mandatory for the FTOA.
11.
64 (97)
Make sure that the cable connector seals are firmly in place.
DN70305645
Issue 2-0 en
17/10/2007
12
12.1
Steps
1.
Fix the upper mounting bracket on the pole and attach the
mounting bracket screws on the bracket.
DN70414583
2.
DN70305645
Issue 2-0 en
17/10/2007
Fix one half of the lower mounting bracket on the Remote Radio
Head.
65 (97)
Installing Flexi WCDMA BTS Modules for Stack, Wall, and Pole
Configurations
DN70414595
3.
Lift the module on the pole and fit it to the mounting screws of
the pole mounting brackets.
DN70414602
4.
5.
66 (97)
DN70305645
Issue 2-0 en
17/10/2007
DN70414614
6.
DN70414723
7.
DN70305645
Issue 2-0 en
17/10/2007
67 (97)
Installing Flexi WCDMA BTS Modules for Stack, Wall, and Pole
Configurations
DN70420998
8.
9.
10
DN70420986
10.
11.
68 (97)
DN70305645
Issue 2-0 en
17/10/2007
10
11
12
DN70421007
12.
13.
DN70305645
Issue 2-0 en
17/10/2007
69 (97)
Installing Flexi WCDMA BTS Modules for Stack, Wall, and Pole
Configurations
13
DN70421019
12.2
70 (97)
Mark the mounting hole locations on the wall and drill the holes
for the screws (or any other fixing method).
DN70305645
Issue 2-0 en
17/10/2007
185mm
(7.3 in.)
1
3
700mm
(27.6 in.)
DN70421022
2.
3.
Lift the Remote Radio Head on the wall and fit it to the mounting
screws.
Tighten the screws.
4.
4
5
DN70421046
DN70305645
Issue 2-0 en
17/10/2007
71 (97)
Installing Flexi WCDMA BTS Modules for Stack, Wall, and Pole
Configurations
5.
6.
DN70421058
7.
72 (97)
DN70305645
Issue 2-0 en
17/10/2007
DN70421073
8.
9.
10.
10
DN70421085
11.
DN70305645
Issue 2-0 en
17/10/2007
73 (97)
Installing Flexi WCDMA BTS Modules for Stack, Wall, and Pole
Configurations
10
11
12
DN70421097
12.
13.
74 (97)
DN70305645
Issue 2-0 en
17/10/2007
13
DN70421116
DN70305645
Issue 2-0 en
17/10/2007
75 (97)
Installing Flexi WCDMA BTS Modules for Stack, Wall, and Pole
Configurations
76 (97)
DN70305645
Issue 2-0 en
17/10/2007
13
Checked
DN70305645
Issue 2-0 en
17/10/2007
77 (97)
Installing Flexi WCDMA BTS Modules for Stack, Wall, and Pole
Configurations
78 (97)
DN70305645
Issue 2-0 en
17/10/2007
Contents of deliveries
A.1
System Module
2 x cable clamps
20 x cable ties
Note
The transmission sub-module is not included in the delivery package. It
must be ordered separately. Make sure you have the correct type of
sub-module.
See the following figure for more information on the delivery contents.
DN70305645
Issue 2-0 en
17/10/2007
79 (97)
Installing Flexi WCDMA BTS Modules for Stack, Wall, and Pole
Configurations
6 x M5
4 x K30
2x
20 x
DN7090562
Figure 26.
A.2
RF Module
Optical cable
Power cable
2 x optical transceivers
10 x cable ties
See the following figure for more information on the delivery contents.
80 (97)
DN70305645
Issue 2-0 en
17/10/2007
Contents of deliveries
6 x M5
10 x
DN7090605
Figure 27.
A.3
Contents of the mounting kit for floor, wall and pole (FMFA) delivery
The FMFA mounting kit is an optional item that has to be ordered
separately, when needed.
The plinth delivery contains the following items:
.
Spring washers (18 pcs for M5 screws and 8 pcs for M8 screws)
12 x M5 screws
6 x M8 screws
See the following figure for more information on the delivery contents.
DN70305645
Issue 2-0 en
17/10/2007
81 (97)
Installing Flexi WCDMA BTS Modules for Stack, Wall, and Pole
Configurations
12 x M5
18 x
6 x M8
8x
DN7090632
Figure 28.
A.4
82 (97)
DN70305645
Issue 2-0 en
17/10/2007
Contents of deliveries
Blocks
M10x120 bolts
M8x25 bolts
M10x200 bolts
M10x300 bolts
Washers
DN0484483
Figure 29.
A.5
4 x screws
See the following figure for more information on the delivery contents.
DN70305645
Issue 2-0 en
17/10/2007
83 (97)
Installing Flexi WCDMA BTS Modules for Stack, Wall, and Pole
Configurations
4 x M5
FCM-FTM
connection card
DN70269818
Figure 30.
FTEB
.
4 x screws
8 x grounding isolators
See the following figure for more information on the delivery contents.
84 (97)
DN70305645
Issue 2-0 en
17/10/2007
Contents of deliveries
8 x grounding
isolators
4 x M5
FCM-FTM
connection card
DN70269872
Figure 31.
FTFA
.
4 x screws
See the following figure for more information on the delivery contents.
DN70305645
Issue 2-0 en
17/10/2007
85 (97)
Installing Flexi WCDMA BTS Modules for Stack, Wall, and Pole
Configurations
4 x M5
FCM-FTM
connection card
DN70269857
Figure 32.
FTIA
.
4 x screws
See the following figure for more information on the delivery contents.
86 (97)
DN70305645
Issue 2-0 en
17/10/2007
Contents of deliveries
4 x M5
FCM-FTM
connection card
DN70269845
Figure 33.
FTOA
.
4 x screws
See the following figure for more information on the delivery contents.
DN70305645
Issue 2-0 en
17/10/2007
87 (97)
Installing Flexi WCDMA BTS Modules for Stack, Wall, and Pole
Configurations
4 x M5
SFP
FCM-FTM
connection card
DN70269821
Figure 34.
FTJA
.
4 x isolators
See the following figure for more information on the delivery contents.
4 x M5
FCM-FTM
connection card
DN70328061
88 (97)
DN70305645
Issue 2-0 en
17/10/2007
Contents of deliveries
A.6
Table 3.
Cable type
Description
Table 4.
470309A
Cable type
Product code
Description
470313A
470310A
Table 5.
DN70305645
Issue 2-0 en
17/10/2007
Product code
Cable type
Product code
Description
FTCH OD CABLE LC SM
1310 15 m (49.2 ft)
470311A
LC to LC fiber
89 (97)
Installing Flexi WCDMA BTS Modules for Stack, Wall, and Pole
Configurations
Table 6.
Cable type
Product code
Description
470311A
Table 7.
90 (97)
FTCR transmission cable delivery (used with the FTIA and FTJA)
Cable type
Product code
Description
471408A
DN70305645
Issue 2-0 en
17/10/2007
B.1
Table 8.
Installation tools
Allen key: 8 mm (0.31 in.)
ESD wrist strap and cable
TORX screwdriver set: T10, T20, T25
Screwdriver set: Phillips 0 , 1, 2 and flathead
Wrench 13 mm (0.51 in.)
Folding knife
Monkey wrench
Side cutters
Crimping tool for 16 mm grounding cable
Torque wrench for antenna cables
Lint-free swab or wipe and 99% alcohol for cleaning optical connectors
Cable ties for routing cables
Tape measure
Flashlight, pocket lamp or torch
Hammer drill
Marker pen or comparable tool
Pliers
B.2
Torque values
Nokia Siemens Networks strongly recommends that you tighten to the
following torque values. These values assume the use of a lubricated bolt
or fastener. Use these values unless stated otherwise.
The torque wrench is presented in the following figure.
DN70305645
Issue 2-0 en
17/10/2007
91 (97)
Installing Flexi WCDMA BTS Modules for Stack, Wall, and Pole
Configurations
DN70234447
Figure 35.
Torque wrench
Table 9.
Bolt/Screw Type
DIN
Size
Torque
7985 F1-60
M3
0.7 - 1.0 Nm
7985 F1-60
7985 F1-60
7985 F1-60
933-12-70
Allen screw
912-A2-70
1.2 - 1.6 Nm
(0.9 - 1.2 ft-lb)
M5
2.0 - 2.5 Nm
(1.5 - 1.8 ft-lb)
M8
10.0 Nm
(7.4 ft-lb)
M12
49.0 Nm
(36.1 ft-lb)
M8
8.0 - 10.0 Nm
(5.9 - 7.4 ft-lb)
Nut
934 A2
M5
3.7 Nm
(2.7 ft-lb)
934 A2
M12
49 Nm
(36.1 ft-lb)
92 (97)
Knurled-head screw
(finger tightening)
-NA-
-NA-
M5
approx. 1 Nm
(0.7 ft-lb)
M4
0.7 Nm
(0.5 ft-lb)
DN70305645
Issue 2-0 en
17/10/2007
Table 9.
DN70305645
Issue 2-0 en
17/10/2007
Bolt/Screw Type
DIN
Size
Torque
-NA-
M4
1.2 Nm
(0.9 ft-lb)
93 (97)
Installing Flexi WCDMA BTS Modules for Stack, Wall, and Pole
Configurations
C.1
94 (97)
DN70305645
Issue 2-0 en
17/10/2007
DN70305645
Issue 2-0 en
17/10/2007
Operating wavelength
range
nm
dB
dBm
dB
- minimum
dB
ps/nm
dB
Attenuation range
Max. dispersion
dBm
- maximum
nm
Spectral characteristics:
Source type
Transmitter at reference
point S
1)
18
40
MLM
NA
0-7
8.2
-15
-8
25
80
LED
1260 -1360
I-1
nm
kbit/s
NA
96
0-12
8.2
-15
-8
7.7
MLM
1261 1360
1)
S-1.1
Values
296
2.5
MLM
NA
0-12
8.2
-15
-8
NA
30
SLM
1430-1576 1430-1580
S-1.2
246
MLM
NA
10-28
10
-5
1)
L-1.1
NA
30
SLM
1263 -1360
155 520
L-1.2
20
NA
10-28
10
-5
30
SLM
14801580
Application code
Digital signal
Unit
Table 10.
10
-5
NA
NA
30
SLM
1480-1580
10-28
246/296
3/2.5
MLM
1523-1577
1534-1566/
L-1.3
95 (97)
96 (97)
dB
dB
Max. reflectance of
receiver, measured at
R
NA
-8
-23
NA
NA
-8
-28
NA
NA
-8
-28
NA
dBm
Min. overload
1)
dBm
dB
Min. sensitivity
Receiver at reference
point R
Max. discrete
reflectance between S
and R
Table 10.
NA
-10
-34
NA
-25
-10
-34
-25
NA
-10
-34
NA
Installing Flexi WCDMA BTS Modules for Stack, Wall, and Pole
Configurations
DN70305645
Issue 2-0 en
17/10/2007
DN70305645
Issue 2-0 en
17/10/2007
97 (97)