You are on page 1of 3

Features supported

Inventory
Details

Storage
Processors

Logical Details

Report Details

LUNs

SP Status

Raid Groups

SP Port status

Host-Port

Disk Drive status

LUN status

SP Ports

Disk
Drives

Monitors

Mappings

Storage Groups

Disk Array

Enclosures

Storage
Processor Enclosures

Capacity
Summary
Availability for
SP / SP Ports

Raid Group status

SP statistics

Disk Array

LUN statistics

Enclosure Status

Disk statistics

Storage Processor
Enclosure Status

Prerequisites for monitoring EMC VNX(Block)

Interconnect
details

OpStor uses command line utility (NaviCLI.exe/NaviSecCLI.exe) available as part


ofNaviSphere suite of EMC VNX(Block)

NaviCLI/NaviSecCLI should be installed in the server in which OpStor is


installed.

Include the directory containing NaviCLI.exe/NaviSecCLI.exe in the PATH system


environment variable. (This is normally C:\Program Files\EMC\Navisphere CLI\ ) by going
into My Computer -> Properties -> Advanced -> Environmental Variables

Ensure that OpStor is restarted (shutdown & started) after including


NaviCLI/NaviSecCLI in the path. This is required for the latest path changes to take
effect for OpStor

Now open a command prompt to execute the navicli command to check for the
proper response from EMC VNX(Block)

Command : navicli -h <array name> getall (for systems with NaviCLI


installed)

Command : naviseccli -h <array name> -scope 0 -user <storage


system username> -password <storage system password> getall (for systems
with NaviSecCLI installed)

Command: naviseccli -h <array name> -scope 0 -user <storage


system username> -password <storage system password> storagepool
-list (for systems with NaviSecCLI installed)

Command: naviseccli -h <array name> -scope 0 -user <storage


system username> -password <storage system password> lun -list (for
systems with NaviSecCLI installed)

Ensure that, OpStor Installed machine is reachable from the Storage system

Steps to add EMC VNX(BLock) in OpStor

In the OpStor client go to Admin Tab --> 'Discovery' Tab

Provide IP Address of EMC VNX Storage Processor

Choose the Device Type as 'RAID'

Choose the Vendor as 'EMC'

Choose the Model as 'VNX-BLOCK'

Provide the NaviSecCLI Username and Password

Change the Timeout if needed

Click on Add Device

Repeat the above procedure to add the second array IP in case of dual Storage
Processors
Note : If the Ping facility is disabled for the device, then please uncheck 'Ping the given IP' field.
Note : In case of non discovery of the device, please follow the troubleshooting tips displayed in
the webclient and try re-adding the device.

You might also like