You are on page 1of 4

Portable Analyzer Product Line

Measure

Technologies

VOCs
ppb, ppm,
%
benzene
1,3 BD
ETO
TCE
PCE
VCM
THC
O2
H 2S
NH3
HCl
HCN
Cl2
H2
NO
NO2
SO 2
CO2
CH4
Hg
others:
Call us

Photoionization, windowless (wl) Photoionization, Flame Ionization,


Combustible Gas (CG), Thermal Conductivity, UV absorbance, Infrared
Absorbance, Electrochemical (>25)

Model 102/102+

Models 107-114

Model GC122

PID

Model 115 FID

Model GC121

Model 80-UV Hg

PID Analyzers, LLC

Hydroarbons, VOCs, LEL, CH4, CH2O, C2H2, Cl2, CO, CO2 Freons, H2, H2O, H2S, HCl,
HCN, ETO, O3, NO, NH3, NO2, PH3, SiH4, SO2,

FIELD PORTABLE ANALYZERS

Model 102 - PID -Analyzers for total VOCs &


Inorganics in air -measure VOCs
PID, 9.5, 10.6 or 11.7 eV heads available
Parameters: PID only
FEATURES Fast response-PID- 1 sec. to 90%
10.5 H x 3W x 2.25"D ; 16 bit ADC;

Applications: Safety, IH. Leak Detection, Accelerants at Arson


scenes, Hazardous waste spills and site evaluations,
transportation, Total VOCs in Air, Water and Soil
Detection of : VOCs (ppm,)

Model 102+ - PID- 1-5 parameters


For the industrial hygienist conducting indoor air pollution
surveys.
Features as above- has software and hardware (amplifiers) to
handle PID and 3-4 other sensors
choose from CG (LEL), TCD, IR (CO2, CH4/LEL, N 2O) and/or
electrochemical sensors
Optional ppb range (10-20,000 ppb)
Detection of : VOCs (ppm, ppb) , O2, CO, H S, PH , SlH , Cl ,
2
3
4
2
HCN, HCl, H , SO , NO, NO
2
2
2

Model 107 Stack Gas Analyzer- 1-4 parameters


Simultaneous Measurement of 4 total- CO2. CO,
NO NO2, SO2:
Optional sampling probe that reduces temperature and
removes excess water from the sample

Model 108- Landfill Gas Analyzer


CH4, O2, CO, H2S
Weight: 1.7 pounds; 2 (IR+ 2 EC sensors),

Special sensors for high levels & acid gases


Sampling systems available

Model 113 Gas Analyzer


1 to 3 Electrochemical (EC) sensors (>25) ,+ CG
(LEL) or TCD

Thermal conductivity (TCD),


Combustible Gas Sensor (CG/LEL)

FEATURES/RANGE
102 PID
Snap-on PID Heads
Measure 1 parameter
Wide range 0.1-3,000 ppm
PID Library for >250 cpds
Easy to calibrate, datalogging
Sensors: PID only

102 + PID
Snap-on heads
Measure PID and 1-4 other
parameters
ppb range 10-20,000
Wide range 0.1-500 ppm.
PID Library for >300 cpds
Sensors: PID, EC (15), CG, TC

107-Stack Gas Analyzer


CO2, CH4,-IR
O2-EC- 0-30%
SO2- EC- 0-4,000
CO- EC- 0-4000
NO-EC
NO2-EC

108- Landfill Gases


CH4-0-100% IR/CO2 0-100%
O20-30% EC
CO- 0-4,000 ppm -EC
H2S- 0-1,000 ppm-EC

113- Gas Analyzer


Measure 4 parameters
(2) EC & CG & O2 - (4) parameters for confined space

> 25 EC sensors

PID, FID, CG, EC (25+), IR,TCD, UV, Portable GCs (121,122, 312)

MODEL 114 IR
IR sensor for CO2 (0-2,000, 5,000 or 10,000
ppm)
IR 114+ can add 1-3 optional electrochemical
sensors

Model 115 FID


Flame Ionization Detector-Requires a belt
mounted low pressure cylinder of hydrogen
stored as a hydride (2#). Contains 70L H2.
Uses a H2 air flame to ionize all
Hydrocarbons

Model GC 121-Portable GC

FEATURES/RANGE
Model 114 IR
CO2- 0-1,000 ppm tp 0-100%
CH4 0-2,500 ppm to 0-100%
N2O- 0-1,000 ppm

Easy to use IR sensor for IH,


IAQ, quality control

Model 115 FID


Ranges: 0-5,000 and 0-50,000 ppm
Detects CH4 and other
hydrocarbons
Measures flame T (oC) + battery
Voltage

Model GC121

Battery operated system (6-8hours)


Dimensions:10.75L x 2.75W X5 H with handle
Weight: 2.7# with 2# carrier gas cylinder

Detectors- PID, wl-PID, FID, FPD (S or P)


Single Detector only
Detects ppb or ppm levels of Hydrocarbons, inorganic
compounds (H2S, NH3, PH3, AsH3 ,,,),
Sulfur compounds, phosphorus compounds, etc.
1-4 compounds, 10 chromatograms stored

ModelGC122 Portable GC

Model GC122

Specs: As above except:


Dimensions: 10 W 4.5: H x 7 D
Weight: 5.2 #
1-10 compounds, 50 chromatograms stored

Model 80- UV Mercury


UV absorbance
Dimensions: 10L x 4.6 H x 6 D
Weight: 7 #
Range: 0.1 to 1,000 ppb
Date storage: 20,000 points

Model 80-UV Mercury

Electrochemical Sensor & General Specifications


Table I
Sensor Specifications
Sensor
Range ppm Det. Limit
Ammonia
0-50
0.1
Carbon Monoxide 0-1,000
0.5
Chlorine
0-10
0.1
ETO
0-100
0.1
Formaldehyde
0-100
0.1
Hydrogen Cyanide 0-100
0.1
Hydrogen Chloride 0-100
0.1
Hydrogen Sulfide 0-100
0.1
Hydrogen Sulfide 0-5,000
0.1
Nitric oxide
0-250
0.1
Nitric oxide-SG
0.1
Nitrogen Dioxide 0-20
0.1
Nitrogen Dioxide-SG
0-200
Oxygen
0-30%
0.1%
Oxygen-SG**
0-30 %
0.1%
Oxygen
0-2%
0.1
Ozone
0-2
0.02
Phosphine
0-5
0.05
Sulfur Dioxide
0-5
0.1
Sulfur Dioxide-SG 0-5000
0.1
Silane
0-5
0.05
Methane
0-100%
1%
Carbon Dioxide 0-5,000
100
PID -ppm
0-3,000
0,1
Combustible Gas 0-100 % LEL
0.1%
Thermal Conductivity 0-100% v/v
0.1%

Resp.Time (s) Interferences/Sensor


30
Acid gases
15
H2, C2H4
30
30
MEK, Ethanol
30
Oxygenated HC
50
C2H4, H2S, SO2
15
SO2, NO2
20
15
SG with filter
10
NO 2
10
with filter
15
NO, H2S
0.1
NO, H2S
8
8
15
75
NO 2
40
SiH2, GH4, B2H6
20
NO 2
20
NO2 filter
30
AsH3, PH3, B2H6
25
___IR Sensor
25
___IR Sensor
1
____
10

15
_____

SG= Stack Gas Sensor, ** Uses acidic electrolyte to prevent interferences from acid gases

General Specifications for non GC Portables


Channels: 1-5 depending on the product; Outputs: 0-1 VDC & RS232; Data storage: 7.500
points, flowrate: 300 cc/min., downloading software to PC included, 1-5 channels,display
2 line by 16 character with backlighting, 16 bit high resolution ADC. all analyzers have
sample pumps.

PID ANALYZERS, LLC


2 Washington Circle, Sandwich, MA 02563
Tel. 1-774-413-5281 USA, Fax. 1-774-413-5298 Web: http://www.hnu.com E-mail: sales@hnu.com
HNU Nordion, Ltd, OY, Atomitie 5 A 3, PL 1, Helsinki, Finland Tel. +358-9-565 7240 Fax +350-9-562 6801
Web: http://www.hnunordion.fi E-mail: Info@hnunordion.fi