Professional Documents
Culture Documents
HIGH STABILITY
PA-6700
SENSITIVITY SELECTABLE
Sensitivity is adjustable by 4 steps : 60%, 80%, 100, 120.
EASY INSTALLATION
Easy separation of the sensor unit and the base unit eases
installation and maintenance.
The sensor unit can be snapped into and out of the base unit. One
touch operation eases installation in high places.
SILENT RELAY
Photo-mos FET switch relay adopted at alarm output. Completely
noiseless by eliminating the movable part which is inside of the relay.
OTHER FEATURES
Distinguishable operation LED.
Alarm LED : Red, Memory LED : Yellow
Wall / Ceiling mounted with optional attachment BCW-401.
Sensor unit
3.88"(98.5mm)
Protection
3.29"(83.5mm)
R0.59"
(R15mm)
8.5'
3
(2.6m) 0
16'
(4.9m)
50' (15.2m)
40'
(12m)
20'
(6m)
35
5-0.17" (4.2mm)
OPTIONAL
Wall mount attachmentBCW-401
PA-6805E (Spot)
53
0'
.2
5
35
"(4
25
Variable range
35
Release lever
67.5
42
Side view
0.
17
35
Side view
0.35"
(9mm)
0.41"
(10.5mm) 1.34"(34mm)
Wire hole
84
30
2.60"(66.7mm)
35
1.85"(47mm)
Top view
Top view
Base unit
4.72"(120mm)
PA-6810E (360
Round)
0.31"
(8mm)
Top view
Top view
45
SPECIFICATIONS
Product name
31
23
29.5'
(9m)
30
41
61
53
15
0'
50'
(15.2m)
Side view
Model
PA-6812E
PA-6810E
Detection system
8.5'
(2.6m)
Variable range
2
32
Side view
66'
(20m)
13'
(4.0m)
25mA Max.
(+2mA at L/C use)
Current consumption
Alarm memory
Red
Alarm LED
Vertically : 30
Adjustment
1 / 2 / 3 / 4 selectable
Alarm output
Dry contact (Semi-Conductor)
N.C./N.O. selectable
Reset : approx. 2 sec.
24V (AC/DC) 0.25A
(Protective resistor 3.3)
Power (non-polarity)
10.528V DC 25mA or less
(+2mA at L/C use)
The power supply used with this unit
must have a minimum 4 hours standby power capbillity.
Vertically : 30
Count changeover
: Flashing at warming up
Lighting at alarm (LED disabled)
Memory LED
Tamper N.C.
30V (AC/DC) 0.25A
8 pairs
10.528V DC (non-polarity)
Alarm signal
TERMINAL ARRANGEMENT
9 pairs
33 pairs
17 pairs
Sensitive zone
Supply voltage
Maximum mounting
height : 16' (4.9m)
PA-6820E
Spot
360Round
Wide angle
Vertical curtain
40' (12m) Max. 50' (15.2m) Max. 13' (4m) Max. 66' (20m) Max.
Coverage
16'
(4.9m)
PA-6805E
Passive infrared
67.5
+5
F to +131
F (-15
C to +55
C ) without condensation
Mounting position
Wiring connection
Weight
Appearance
Accessory
3.85oz (110g)
Body : ABS resin
Tapping screw : 2 pcs.
Cover : PE resin
Sensor locking screw : 1 pce.
Please Note : This sensor is designed to detect intrusion and to initiate an alarm; it is not a burglary-preventing device. TAKEX is not
responsible for damage, injury or losses caused by accident, theft, Acts of God (including inductive surge by lightning),
abuse, misuse, abnormal usage, faulty installation or improper maintenance.
In Japan
In the U.S.
In Australia
In the U.K.
Takex America Inc.
Brisbane office : 1/50 Logan
Road, Woolloongabba
Queensland
4102, Australia
Tel : 07-3891-3344
Fax : 07-3891-3355
LEAF 10-04P12-15