TrueNet Fiber Optic Cable

In/Outdoor Dry Loose Tube Cables: Riser and Plenum

Spec Sheet

ADCs innovative line of indoor/outdoor loose tube cables are designed to meet all the rigors
of the outside plant environment and have the necessary fire ratings to be installed inside the
building. These cables eliminate the messy gel filler of traditional loose tube style cables with
super absorbent polymers. The installer can place the cable anywhere in the network, bypassing
the transition points required in most installations. Cables are available with fiber counts from
2 to 144.

Features:

Applications:

Dry cable core and dry buffer tubes provide


effective water blocking without the need
for traditional gel filler

Between buildings in campus


backbone cabling

Can be placed anywhere in the network,


bypassing transition points from outdoor to
indoor

Outside plant

Installation times reduced because there is


no need to clean gels

Riser or plenum rated environments

Compliances:
Telcordia GR-20-CORE

Excellent flame retardancy

Telcordia GR-409-CORE

Flexible design for easy installation

EIA/TIA FOTPs

Color-coded buffer tubes and fibers

ETL, (UL) 910, NEC OFNP, FT-6

Wide operating temperature range:


-40 to 75 C (-40 to 167 F)

ETL, (UL) 1666, NEC OFNR, FT-4


ISO/IEC 11801
EIA/TIA 568-B
ANSI/ICEA S-104-696

www.adc.com

+1-952-938-8080

1-800-366-389 1

TrueNet Fiber Optic Cable

In/Outdoor Dry Loose Tube Cables: Riser and Plenum

12 Fiber Cable

144 Fiber Cable


250 m UV Colored
Optical Fiber

250 m UV Colored
Optical Fiber

3.0 mm Thermoplastic
Tube Drygel Water
Blocked

3.0 mm Thermoplastic
Tube Drygel Water
Blocked

Strength Member

Central Strength
Members

Flame Retardant Inner


and Outer Jacket

Strength Member
Flame Retardant Inner
and Outer Jacket

Environmental Characteristics
Storage Temperature:
-40 to 85 C (-40 to 180 F)
Operating Temperature:
-40 to 75 C (-40 to 167 F)
Installation Temperature:
0 to 60 C (-32 to 140 F)
Mechanical Characteristics
Riser:

Fiber Count
2-12

Maximum Tensile Load N (ibf)


Short Term (install):
Long Term:
Minimum Bend Radius cm (in)
Short Term (install):
Long Term:

18-24

36-48

60-72

84

96

108

120

132

144

1335 (300) 1335 (300) 2670 (600) 2670 (600) 2670 (600) 2670 (600) 2670 (600) 2670 (600) 2670 (600) 2670 (600)
400 (90)
400 (90) 890 (200) 890 (200) 890 (200) 890 (200) 890 (200) 890 (200) 890 (200) 890 (200)

9.7 (3.8)
6.5 (2.6)

18.9 (7.4)
12.6 (5.0)

15.1 (5.9)
10.1 (4.0)

17.8 (7.0)
11.9 (4.7)

Plenum:

19.4 (7.7)
13.0 (5.1)

20.6 (8.1)
13.7 (5.4)

22.5 (8.9)
15.0 (5.9)

24.2 (9.5) 25.6 (10.1) 27.2 (10.7)


16.2 (6.4) 17.1 (6.7) 18.1 (7.1)

Fiber Count
2-12

Maximum Tensile Load N (ibf)


Short Term (install):
Long Term:
Minimum Bend Radius cm (in)
Short Term (install):
Long Term:

18-24

36-48

60-72

84

96

108

120

132

144

1335 (300) 1335 (300) 2670 (600) 2670 (600) 2670 (600) 2670 (600) 2670 (600) 2670 (600) 2670 (600) 2670 (600)
400 (90)
400 (90) 890 (200) 890 (200) 890 (200) 890 (200) 890 (200) 890 (200) 890 (200) 890 (200)

9.9 (3.9)
6.6 (2.6)

18.9 (7.4)
12.6 (5.0)

14.1 (5.6)
9.4 (3.7)

17.5 (6.9)
11.7 (4.6)

18.5 (7.3)
12.3 (4.9)

20.0 (7.9)
13.4 (5.3)

21.6 (8.5)
14.4 (5.7)

23.1 (9.1)
15.4 (6.1)

24.7 (9.7) 26.4 (10.4)


16.5 (6.5) 17.6 (6.9)

2/07

103936AE

In/Outdoor DLT Cables: Riser and Plenum

Specifications

www.adc.com

+1-952-938-8080

1-800-366-3891

TrueNet Fiber Optic Cable

In/Outdoor Dry Loose Tube Cables: Riser and Plenum


Maximum
Attenuation (dB/km)

Typical Attenuation
(dB/km)

Bandwidth1
(MHz/km)

850 nm/1300 nm

850 nm/1300 nm

850 nm/1300 nm

62.5/125

3.5/1.5

3.0/1.0

200/500

OM1

50/125

3.5/1.5

3.0/1.0

500/500

OM2

50/125 laser optimized


to 150 meters

500/500

OM2

3.5/1.5

3.0/1.0

50/125 laser optimized


to 300 meters

1500/5002

OM3

3.5/1.5

3.0/1.0
47002/5001

OM3

Multimode

50/125 laser optimized


to 550 meters

3.5/1.5

3.0/1.0

1310 nm/1550 nm

1310 nm/1550 nm

1310 nm/1550 nm

1.0/1.0

0.4/0.3

N/A

Singlemode
1
2

ISO/IEC
Type

OS1

Bandwidth measurements specified overfilled launch conditions (OFL)


Bandwidth measurements specified by laser launch

Transmission performance
Guaranteed Minimum Link Lengths

Gigabit Ethernet
10 Gigabit Ethernet
Link Length (SX/LX) Link Length (SR/LX4)3

Jacket
Color

Multimode
62.5/125

300 m/550 m

35 m/300 m

Orange

50/125

750 m/500 m

150 m/300 m

Orange

50/125 Ultra laser optimized to 300 meters

900 m/550 m

300 m/300 m

Aqua

50/125 Ultra laser optimized to 550 meters

900 m/550 m

550 m/550 m

Aqua

NA/5000 m

10 km/40 km

(LR/ER)
Singlemode

Yellow

10 Gigabit Ethernet distance guarantees at the long wavelength are achieved via four 3.125 Gbps channels
multiplexed with WWDM technology.
3

2/07

103936AE

In/Outdoor DLT Cables: Riser and Plenum

optical performance

www.adc.com

+1-952-938-8080

1-800-366-3891

Ordering Information
Diameter

Weight

Cable Type

Fibers

mm

in

kg/km

lb/10001

Catalog Number*

Dry loose tube:


indoor/outdoor,
Riser

2-12

6.6

0.26

48

32

QXXXDLTIORYYY

18-36

10.4

0.41

133

77

48-60

11.5

0.45

110

74

72

12.4

0.49

156

105

84

13.3

0.52

171

115

96

14.3

0.56

206

138

108

15.2

0.60

229

154

120

16.2

0.64

261

175

132

17.2

0.68

295

198

144

18.2

0.72

337

226

2-12

6.6

0.26

48

32

18-72

11.7

0.46

130

87

84

12.6

0.50

138

96

96

13.6

.54

163

110

108

14.6

0.57

192

129

120

15.7

0.62

223

150

132

16.6

0.66

257

172

144

17.6

0.70

294

197

Dry loose tube:


indoor/outdoor,
Plenum

QXXXDLTIOPYYY

Spec Sheet

*Replace XXX with fiber count, i.e. 2 fibers = 002"


*Replace YYY with fiber type:
010 = Singlemode
062 = 62.5/125 m multimode
50E = 50/125 m multimode/orange jacket
50A = 50/125 m multimode laser optimized to 150 meters/aqua jacket
50U = 50/125 m multimode laser optimized to 300 meters
5U5 = 50/125 m multimode laser optimized to 550 meters

Premier infrastructure solutions


Web Site: www.adc.com
From North America, Call Toll Free: 1-800-366-3891 Outside of North America: +1-952-938-8080
Fax: +1-952-917-3237 For a listing of ADCs global sales office locations, please refer to our Web site.
ADC Telecommunications, Inc., P.O. Box 1101, Minneapolis, Minnesota USA 55440-1101
Specifications published here are current as of the date of publication of this document. Because we are continuously
improving our products, ADC reserves the right to change specifications without prior notice. At any time, you may
verify product specifications by contacting our headquarters office in Minneapolis. ADC Telecommunications, Inc.
views its patent portfolio as an important corporate asset and vigorously enforces its patents. Products or features
contained herein may be covered by one or more U.S. or foreign patents. An Equal Opportunity Employer
103936AE 2/07 Revision 2006, 2007 ADC Telecommunications, Inc. All Rights Reserved

You might also like