Professional Documents
Culture Documents
RiT Technologies Ltd. 24 Raoul Wallenberg St., Tel Aviv 69719, Israel
Tel: +972-3-645-5151 Fax: +972-3-647-4115
www.rittech.com
Page 1 of 7
Datasheet
Tight Buffer Fiber-Optic Cables
Description
Water
swelling glass yarns are used with fibers to strengthen and block cable core from water
penetration. Cable core is covered by a Low Smoke, Zero Halogen (LSZH) outer jacket.
RiT Technologies Ltd. 24 Raoul Wallenberg St., Tel Aviv 69719, Israel
Tel: +972-3-645-5151 Fax: +972-3-647-4115
www.rittech.com
Page 2 of 7
Datasheet
Tight Buffer Fiber-Optic Cables
Specifications
Mechanical and Environmental Characteristics
Test
Detail Specifications
1500 N
Maximum Operating
Load
Test Procedure
IEC-60794-1TIA/EIA-455
2 Test Method
FOTP No
E1
33
E1
33
E11
104
20 x cable O.D
10 x cable O.D
Max. Compressive
Loading
2,000N
E3
41
Repeated Impact
E4
25
Twist (Torsion)
E7
85
F1
-20C to +50C
F1
Storage Temperature
Range
Operating Temperature
Range
Nom. Cable
weight
(kg/km)
17
25
33
12
7.5
45
RiT Technologies Ltd. 24 Raoul Wallenberg St., Tel Aviv 69719, Israel
Tel: +972-3-645-5151 Fax: +972-3-647-4115
www.rittech.com
Page 3 of 7
Datasheet
Tight Buffer Fiber-Optic Cables
Specifications
Fiber-Optic Cable Standard Color Code
Unit
Number
Color
Unit
Number
Color
Blue
Red
Orange
Black
Green
Yellow
Brown
10
Violet
Grey
11
Pink
White
12
Turquoise
RiT Technologies Ltd. 24 Raoul Wallenberg St., Tel Aviv 69719, Israel
Tel: +972-3-645-5151 Fax: +972-3-647-4115
www.rittech.com
Page 4 of 7
Datasheet
Tight Buffer Fiber-Optic Cables
Specifications
Single-Mode Fibers Standard Specifications
Parameter
Standard per
ITU-T G.652D
Units
@1310 nm
0.38
dB/km
@1550 nm
0.28
Attenuation
3.5
18
ps/(nm*km)
22
131111
9.20.5
@1550 nm
10.41.0
nm
m
1260
nm
0.2
ps/km1/2
1251.0
0.5
Cladding Non-Circularity
1.0
24510
0.7
GN/m2
Coating Diameter
Proof-Test Level
RiT Technologies Ltd. 24 Raoul Wallenberg St., Tel Aviv 69719, Israel
Tel: +972-3-645-5151 Fax: +972-3-647-4115
www.rittech.com
Page 5 of 7
Datasheet
Tight Buffer Fiber-Optic Cables
Specifications
Multi-Mode Fibers Standard Specifications
Parameter
ISO/IEC 11801
Classification(2)
50/125
m
50/125
m
62.5/125
m
Units
OM2
OM3
OM1
3.5
1.0
db/km
200
500
MHz*km
3.2
1.0
500(3)
800(3)
Numerical Aperture
2000(4)
500
0.20>0.015
0.2750.015
503
62.53
1252
1252
Cladding Non-Circularity
Core/Cladding Offset
24510
24510
0.7
0.7
GN/m2
Core Diameter
Cladding Diameter
Coating Diameter
Proof-Test Level
RiT Technologies Ltd. 24 Raoul Wallenberg St., Tel Aviv 69719, Israel
Tel: +972-3-645-5151 Fax: +972-3-647-4115
www.rittech.com
Page 6 of 7
Datasheet
Tight Buffer Fiber-Optic Cables
Specifications
Multi-Mode Fiber GbE and 10 GbE Link Lengths
Fiber Type
62.5/125 m
50/125 m
50/125 m
OM-1
OM-2
OM-3
200 MHz.km
500 MHz.km
2000 MHz.km
500 MHz.km
500 MHz.km
500 MHz.km
@ 850 nm (1000BASESX)
@ 1300 nm (1000BASELX)
Link Length for 10 GbE(6)
220 m
550 m
550 m
550 m
970 m
550 m
@ 850 nm (10GBASE-SR)
@1300 nm (10GBASELX4)
33 m
300 m
82 m
300 m
300 m (8)
300 m
11801 Classification(2)
Bandwidth (3):
@850 nm
@1300 nm
(5)
1. For other fiber specification and additional details, consult RiTs sales
department.
2. As per ISO/IEC 11801:2002 or EN 50173.
3. Overfill launch measurement as per TIA-455-204
4. Effective Modal Bandwidth as per IEC 60793-2.10
5. Per IEEE 802.3z, assuming the requirements of the standard and associated
documents are met.
6. Per IEEE 802.3ae, assuming the requirements of the standard and associated
documents are met.
7. Calculated using the 10GbE link model
8. This link length is assured provided that:
a. It is installed per the maximum channel insertion loss requirement of 2.6dB
as outlined in the TIA 568 B.3-1, ISO 11801 2nd Ed, and IEEE 802.3ae. The
maximum channel insertion loss requirement of 2.6 dB assumes a maximum
connection loss of 1.5 dB and a maximum cable attenuation of 3.5 dB/km at
850nm.
b. It is used with an IEEE 802.3ae compliant 10GBASE-SR or 10GBASE-SW
ports meeting the specifications, among other, for encircled flux as defined
in Table 52.7 in IEEE 802.3ae.
RiT Technologies Ltd. 24 Raoul Wallenberg St., Tel Aviv 69719, Israel
Tel: +972-3-645-5151 Fax: +972-3-647-4115
www.rittech.com
Page 7 of 7