Generator Set Data Sheet

Model:
Frequency:
Fuel Type:
Emissions Performance NOx:
LT Water Inlet Temperature:
HT Water Outlet Temp:

Measured Sound Performance Data Sheet:


Prototype Test Summary Data:
Remote Radiator Cooling Outline:

1250GQNA
60 Hz
Natural Gas MI 60 +
500 mg/Nm3 (1.2 g/hp-h)
50oC (122oF)
95oC (203oF)
TBD
PTS-282
0500-4293

100% of Rated
Load

90% of Rated
Load

Fuel Consumption (ISO3046/1)

See Note

Fuel Consumption (LHV) ISO3046/1, kW (MMBTU/hr)


Mechanical Efficiency ISO3046/1, percent
Electrical Efficiency ISO3046/1, percent

2,4,6,7 3391 (11.58) 3105 (10.6)


2,4,7
38.6%
37.9%
2,4,6,7
36.9%
36.2%

75% of Rated
Load

50% of Rated
Load

2662 (9.09)
36.9%
35.2%

N/A
N/A
N/A

Engine
Engine Manufacturer
Engine Model
Configuration
Displacement, L (cu.in)
Aspiration
Gross Engine Power Output, kWm (hp)
BMEP, bar (psi)
Bore, mm (in)
Stroke, mm (in)
Rated Speed, rpm
Piston Speed, m/s (ft/min)
Compression Ratio
Lube Oil Capacity, L (qt)
Overspeed Limit, rpm
Regenerative Power, kW
Full Load Lubricating oil consumption, g/kWe-hr (g/hp-hr)

Cummins
QSV91G
V18
91.6 (5591)
Turbocharged (4)
1309 (1755)
13.9 (202)
180 (7.09)
200 (7.87)
1200
8 (1574)
11.4:1
560 (592)
1440
N/A
0.5 (0.67)

Fuel
Gas supply pressure to engine inlet, bar (psi)
Minimum Methane Index

0.2 (3.0)
60

Starting System(s)
Electric starter voltage, volts
Minimum battery capacity @ 40 deg.C (104 deg.F), AH
Air Starter Pressure, barg (psig)
Air Starter Flow Nm3/s (scfm)

24
720
10.3 (150)
0.37 (780)

Genset Dimensions (see note 1)


6.24 (20.48)
2.10 (76.89)
2.97 (9.75)
19317 (42,587)

Genset Length, m (ft)


Genset Width, m (ft)
Genset Height, m (ft)
Genset Weight (wet), kg (lbs)

2007 Cummins Power Generation

Specifications May Change Without Notice

D-3282c (May 07) Page 1 of 4

Energy Data
Continuous Shaft Power, kWm (bhp)
Continuous Generator Electrical Output kWe @ 1.0 pf
Heat Dissipated in Lube Oil Cooler, kW (MMBTU/h)
Heat Dissipated in Block, kW (MMBTU/h)
Total Heat Rejected in LT Circuit, kW (MMBTU/h)
Total Heat Rejected in HT Circuit, kW (MMBTU/h)
Unburnt, kW (MMBTU/h)
Heat Radiated to Ambient, kW (MMBTU/h)
Available Exhaust heat to 105C, kW (MMBTU/h)
Intake Air Flow
Intake Air Flow Mass, kg/s (lb/hr)
Intake Air Flow Volume, m3/s @ 0oC (scfm)
Maximum Air Cleaner Restriction, mmHG (in H2O)

See
Notes

100% of Rated
Load

90% of Rated
Load

75% of Rated
Load

2,10
6,10
5
5
5
5
13
13
5

1309 (1755)
1250
172 (0.59)
512 (1.75)
313 (1.07)
624 (2.13)
93 (0.32)
235 (0.80)
907 (3.09)

1178 (1579)
1125
163 (0.56)
500 (1.71)
296 (1.01)
578 (1.97)
86 (0.29)
214 (0.73)
844 (2.88)

983 (1317)
937.5
144 (0.49)
516 (1.76)
256 (0.87)
542 (1.85)
77 (0.26)
183 (0.63)
705 (2.40)

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

4
4

1.95 (15468)
1.51 (3382)
36.70 (19.7)

1.77 (14018)
1.37 (3065)
33.03 (17.7)

1.47 (11642)
1.14 (2545)
27.53 (14.8)

N/A
N/A
N/A

50% of Rated
Load

Exhaust Air Flow


Exhaust Gas Flow Mass, kg/s (lb/hr)
Exhaust Gas Flow Volume, m3/s (cfm)
o
o
Exhaust Temperature After Turbine, C ( F)
Max Exhaust System Back Pressure, mmHG (in H2O)

4
4
2,6
6,14

2.02
4.42
500
37.3

Min Exhaust System Back Pressure, mmHG (in H2O)

6,14

18.7 (10.0)

18.7 (10.0)

18.7 (10.0)

18.7 (10.0)

8
8

424
41
82
95
1.0
4.5
0.5

(112)
(181)
(180)
(203)
(15)
(65)
(7)

424
41
82
95
1.0
4.5
0.5

(112)
(181)
(180)
(203)
(15)
(65)
(7)

424
41
82
95
1.0
4.5
0.5

(112)
(181)
(180)
(203)
(15)
(65)
(7)

424
41
82
95
1.0
4.5
0.5

(112)
(181)
(180)
(203)
(15)
(65)
(7)

9
9

295
30.00
50
60.0
1.0
4.5
0.5

(78)
(132)
(122)
(140)
(15)
(65)
(7)

295
30.00
50
60.0
1.0
4.5
0.5

(78)
(132)
(122)
(140)
(15)
(65)
(7)

295
30.00
50
60.0
1.0
4.5
0.5

(78)
(132)
(122)
(140)
(15)
(65)
(7)

295
30.00
50
60.0
1.0
4.5
0.5

(78)
(132)
(122)
(140)
(15)
(65)
(7)

HT Cooling Circuit
HT Circuit Engine Coolant Volume, l (gal)
HT Coolant Flow @ Max Ext Restriction, m3/h (gal/min)
o
o
Max HT Engine Coolant Inlet Temp, C ( F) Reference
o
o
HT Coolant Outlet Temp, C ( F)
Max Pressure Drop in External HT Circuit, bar (psig)
HT Circuit Maximum Pressure, bar (psig)
Minimum Static Head, bar (psig)
LT Cooling Circuit
LT Circuit Engine Coolant Volume, l (gal)
3
LT Coolant Flow @ Max Ext Restriction, m /h (gal/min)
o
o
Maximum LT Engine Coolant Inlet Temp, C ( F)
o
LT Coolant Outlet Temp, oC ( F) Reference Only
Max Pressure Drop in External LT Circuit, bar (psig)
LT Circuit Maximum Pressure, bar (psig)
Minimum Static Head, bar (psig)

(15998)
(9363)
(932)
(20.0)

1.84
4.07
508
37.3

(14573)
(8617)
(946)
(20.0)

1.52
3.38
512
37.3

(12038)
(7155)
(954)
(20.0)

N/A
N/A
N/A
37.3 (20.0)

Emissions
NOx Emissions wet, ppm

152

143

154

N/A

NOx Emissions at Exhaust Condition, mg/Nm3 (g/hp-h)


THC Emissions wet, ppm
THC Exhaust Emissions, mg/Nm3 (g/hp-h)
CH4 Emissions wet, ppm
CH4 Emission, mg/Nm3 (g/hp-h)
NMHC Emissions wet, ppm
NMHC Exhaust Emissions, mg/Nm3 (g/hp-h)
CO Emissions (dry), ppm
CO Emissions Rate at Exhaust Condition, mg/Nm3
O2 Emissions (dry), percent
Particulates PM10, g/hp-h

4
13
13
13
13
13
13
13
13
13
13

493 (1.21)
N/A
N/A
1615
1820 (4.46)
N/A
N/A
647
1100 (2.70)
9.4
N/A

463 (1.16)
N/A
N/A
1660
1860 (4.67)
N/A
N/A
655
1110 (2.80)
9.4
N/A

495 (1.25)
N/A
N/A
1805
2010 (5.08)
N/A
N/A
678
1140 (2.90)
9.2
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

2007 Cummins Power Generation

Specifications May Change Without Notice

D3282c (May 07) Page 2 of 4

Genset De-rating
Altitude and Temperature Derate Multiplication Factor
Barometer

Altitude

In Hg

mbar

Feet

20.7
21.4
22.1
22.8
23.5
24.3
25.0
25.8
26.6
27.4
28.3
29.1
29.5
30.0

701
723
747
771
795
820
846
872
899
926
954
983
995
1012

9843
9022
8202
7382
6562
5741
4921
4101
3281
2461
1640
820
492
0

Table A *

Meters

3000
2750
2500
2250
2000
1750
1500
1250
1000
750
500
250
150
0
C
F

Derate Multiplier with Grid Parallel Operation


0.93
0.96
0.99
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00

0.89
0.92
0.95
0.98
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00

0.85
0.88
0.91
0.94
0.97
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00

0.81
0.84
0.87
0.90
0.93
0.96
0.99
1.00
1.00
1.00
1.00
1.00
1.00
1.00

N/A
0.80
0.83
0.86
0.89
0.93
0.95
0.98
1.00
1.00
1.00
1.00
1.00
1.00

N/A
N/A
0.79
0.82
0.85
0.88
0.91
0.95
0.98
1.00
1.00
1.00
1.00
1.00

N/A
N/A
N/A
0.78
0.81
0.84
0.87
0.90
0.93
0.96
1.00
1.00
1.00
1.00

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

20

25

30

35

40

45

50

55

60

68

77

86
95
104
113
Air Filter Inlet Temperature

122

131

140

Temperature & Altitude Derate


1. Determine derate multiplier vs.
temperature and altitude in Table A
or B depending upon your operating
condition.
2. Assumes the LT return
temperature is 10 deg C above the
air filter inlet with a maximum LT
temperature of 50 deg C.
3. If the LT temperature exceeds 50
deg C, consult factory for
recommendations.
4. Altitude is based upon SAE
standard ambient pressure vs.
altitude. For low barometric
conditions add 150m (500 ft) to site
altitude.

* Based on SAE standard ambient pressure vs. altitude. Assumes LT return temperature is 10C above air filter inlet.

Barometer

Altitude

In Hg

mbar

Feet

Meters

20.7
21.4
22.1

701
723
747
771
795
820
846
872
899
926
954
983
995
1012

9843
9022
8202
7382
6562
5741
4921
4101
3281
2461
1640
820
492
0

3000
2750
2500
2250
2000
1750
1500
1250
1000
750
500
250
150
0

22.8
23.5
24.3
25.0
25.8
26.6
27.4
28.3
29.1
29.5
30.0

C
F

Table B *
Derate Multiplier Off Grid (Island or Load Share)
0.84
0.88
0.91
0.94
0.97
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00

0.81
0.84
0.87
0.91
0.94
0.97
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00

20
68

25
77

0.78
0.81
0.84
0.87
0.90
0.94
0.97
1.00
1.00
1.00
1.00
1.00
1.00
1.00

N/A
N/A
0.80
0.84
0.87
0.90
0.93
0.96
1.00
1.00
1.00
1.00
1.00
1.00

N/A
N/A
N/A
N/A
0.80
0.83
0.86
0.90
0.93
0.96
0.99
1.00
1.00
1.00

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
0.78
0.86

Methane Number Capability

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

30
35
40
45
50
86
95
104
113
122
Air Filter Inlet Temperature

55
131

60
140

Load (Percent of Rated)


75%
50%
100%
90%
60
55
52
52

* Based on SAE standard ambient pressure vs. altitude. Assumes LT return temperature is 10C above air filter inlet.

Heat Rejection Factor (altitude and ambient) for HT and LT Circuits


Barometer

Altitude

In Hg

mbar

Feet

Meters

20.7
21.4
22.1
22.8
23.5
24.3
25.0
25.8
26.6
27.4
28.3
29.1

701
723
747
771
795
820
846
872
899
926
954
983
995
1012

9843
9022
8202
7382
6562
5741
4921
4101
3281
2461
1640
820
492
0

3000
2750
2500
2250
2000
1750
1500
1250
1000
750
500
250
150
0

29.5
30.0

C
F

Table C
Multiplier for HT & LT Heat Rejection vs Alt & Temp.
1.11
1.10
1.09
1.08
1.07
1.06
1.05
1.04
1.02
1.01
1.00
0.99
0.99
0.98

1.13
1.12
1.10
1.09
1.08
1.07
1.06
1.05
1.04
1.03
1.02
1.00
1.00
0.99

20
68

25
77

2007 Cummins Power Generation

1.14
1.13
1.12
1.11
1.09
1.08
1.07
1.06
1.05
1.04
1.03
1.02
1.01
1.01

1.15
1.14
1.13
1.12
1.11
1.10
1.09
1.07
1.06
1.05
1.04
1.03
1.03
1.02

1.17
1.15
1.14
1.13
1.12
1.11
1.10
1.09
1.08
1.07
1.05
1.04
1.04
1.03

1.18
1.17
1.16
1.14
1.13
1.12
1.11
1.10
1.09
1.08
1.07
1.06
1.05
1.05

1.19
1.18
1.17
1.16
1.15
1.14
1.12
1.11
1.10
1.09
1.08
1.07
1.06
1.06

1.20
1.19
1.18
1.17
1.16
1.15
1.14
1.13
1.12
1.10
1.09
1.08
1.08
1.07

1.22
1.21
1.20
1.18
1.17
1.16
1.15
1.14
1.13
1.12
1.11
1.10
1.09
1.08

30
35
40
45
50
86
95
104
113
122
Air Filter Inlet Temperature

55
131

60
140

Specifications May Change Without Notice

LT & HT Circuit Heat Rejection


Calculation
1. Determine derate multiplier vs.
temperature derate per above.
2. Using the multiplier from #1 above
as the percent load factor determine
the Heat rejection from the previous
page.
3. From Table C find the HT and LT
circuit multiplier.
4. Multiply the result of step 2 by the
result of step 3 to obtain the heat
rejection at your altitude and
temperature.

D3282c (May 07) Page 3 of 4

Alternator Data
Voltage Range
440-480
600

Connection
Configuration
Wye, 3 Phase
Wye, 3 Phase

Continuous Rating
Definition

Temp Rise
Degrees C
125
125

Duty11
Cycle
C
C

Single Phase Maximum


Factor
Surge kVA12
N/A
5202
N/A
5202

Alternator
Data Sheet
539
539

Feature
Code
B650-2
B651-2

Applicable for supplying power continuously to a constant load up to the full


output rating for unlimited hours. No sustained overload capability is available
for this rating. Consult authorized distributor for rating. (Equivalent to
Continuous Power in accordance with ISO8528, ISO3046, AS2789, DIN6271, and
BS5514). This rating is not applicable to all generator set models.

Notes
1) Weights and set dimesions represent a generator set with its standard features only. See outline drawing for other configurations.
2) At ISO3046 reference conditions, altitude 1013 mbar (30in Hg), air inlet temperature 25C (77F)
3) Nominal performance +/- 2 %.
4) According to ISO 3046/I with fuel consumption tolerance of +5% -0% or efficiency tolerance of +0% -5%.
5) Production variation/tolerance +5%
6) At electrical output of 1.0 Power Factor
3

7) Tested using pipeline natural gas with LHV of 33.44mJ/Nm (905 BTU/ft3)
8) Outlet temperature controlled by thermostat. Inlet temperature for reference only.
9) Inlet temperature controlled by thermostat. Outlet temperature for reference only.
10) With engine driven coolant pump
11) Standby (S), Prime (P), Continuous (C) ratings.
12) Maximum rated starting kVA that results in minimum of 90% of rated sustained voltage during starting.
13) Tolerance +/- 15%.
14) Exhaust system back pressure is a rated load and will decrease at lower loads.

See your distributor for more information.

Cummins Power Generation


1400 73rd Avenue N.E.
Minneapolis, MN 55432 USA
Telephone: +1 (763) 574-5000
Fax: +1 (763) 574-5298
Email: pgamail@cummins.com
Web: www.cumminspowergeneration.com

Cummins Power Generation


Manston Park, Columbus Avenue
Manston, Ramsgate
Kent CT12 5BF, UK
Telephone: +44 (0) 1843 255000
Fax: +44 (0) 1843 255902
E-Mail: cpg.uk@cummins.com
Web: www.cumminspower.com

Cummins Power Generation


8 Tanjong Penjuru
Singapore 609019
Telephone: +65 265-0155
Fax: +65 264-0664 or 265-6909
Email: mktg@sing.cummins.com

Cummins and PowerCommand are registered trademarks of Cummins Inc. AmpSentry is a trademark of Cummins Inc.
Important: Back feed to a utility system can cause electrocution and/or property damage. Do not connect to any building's electrical system
except through an approved device or after building main switch is open.

2007 Cummins Power Generation

Specifications May Change Without Notice

D-3282c (May 07) Page 4 of 4