Tank diameter
Tank Height
Calculated Tank Capacity
Required Tank Capacity
D
H
8.20
9.50
501.70
425.00
Width of
each
strake
in m
Level from
base
of tank
in m
1
2
3
4
2.40
2.40
2.40
2.30
0.00
2.40
4.80
7.20
9.50
Sum
9.50
22-17058
m
m
cu.m
cu.m
OK
6.0 mm
1.0 mm
Project No.
Design
Liquid
Level
in m
hp
9.50
7.10
4.70
2.30
Design
shell
thickness
in mm
t
5.3
4.2
3.1
2.1
103.4 MPa
1.00
1.0 mm
Adopted
Shell
Plate
thickness
in mm
Weight of
Shell
Plate
excluding
CA
6
6
6
6
24.27
24.27
24.27
23.26
96.06
20.73
116.78
115.27 kN
24.87 kN
1.19 m
Formula
s -> Allowable Design stress in shell plate as per Table 5 , AWWA D100-05
s=
103.4 Mpa
E -> Joint Efficiency
From table15, Joint Efficiency for single -groove butt joint in shell =
85
Required shell thickness t = { 4.9 * hp * D * G / ( s *E) } + CA
Eq. 3-40
From table 16 , AWWA D100-05
Minimum thickness of tank shell plate in contact with water =
4.76
Required shell thickness including C.A
=
5.76
Minimum adopted shell plate thickness
=
6
Hence OK
mm
mm
mm
Project :
1
2
3
4
0.00
2.40
4.80
7.20
9.50
2400
2400
2400
2300
6
6
6
6
Actual shell
thickness
minus corrosion
thickness
t actual - CA
8.20 m
9.50 m
A2
141 km / h
6 mm
5 mm
Transposed
width of
each shell
in mm
W tr
5.0
5.0
5.0
5.0
2400.00
2400.00
2400.00
2300.00
Sum
9500.00 mm
9.500 m
Height of Transformed Shell
=
Maximum Height of unstiffened shell H1 =
40.938 m
H1
greater than
Height of Transformed Shell
Intermediate Wind Girder NOT Required
3
0.00 cm
Formula
0.06713HD2Paw
Project :
=
=
8.20 m
9.50 m
6 mm
2.0 mm
8.0 mm
6.35 mm
1.0 mm
7.4 mm
8 mm
1 deg.
132.41 MPa
61.61 MPa
9.50 m
8 excluding CA
10.0 mm
10.0 mm
600 mm
650 mm
750 mm
50 mm
OK
cl. 5.4.2
OK
Project :
8.20 m
9.50 m
425.00 cu.m
V
pshell
=0.86(V/190)2
141.00 km / h
0.47 kPa
proof
=1.44(V/190)2
0.79 kPa
0.78 kPa
0.73 kPa
W roof plate
96.06 kN
20.73
11.10
31.83
0
W roof
kN
kN
kN
kPa
Mw =
460.33 kNm
Mpi =
0 kNm
MDL =
524.3305 kNm
wL =
Weight of band of liquid at the shell using
G=0.7 and height of one-half of design liquid height
wL = 59 (tb - CA) (Fby. H)1/2
MF
2429.525 kNm
0.6Mw + Mpi
<
276.20
Check 2
23002.43 N/m
Mw + 0.4 Mpi
460.3293
<
<
<
MDL / 1.5
349.5537
OK
(MDL + MF ) / 2
1476.928
OK
36.89 kN
51.15 kN
Project :
Project No.
Tank diameter
Tank Height
Tank Capacity
Tank Content Specific Gravity
D=
H=
G
Sp =
Ss =
S1 =
S0 =Sp
8.20 m
9.50 m
425.00 cu.m
1.00
0.40
0.4
0.218
0.40
I
D
Mechanically Anchored
1.48
1.98
1.00
3.00
1.50
0.67
Ks =
Tc =
TL =
(for outside USA )
Ai =
22-17085
clause E4.3-1
clause E4.3-2
Eqn. 13-8
0.58
2.98 sec
4 sec
0.329
Ai > 0.007 OK
0.121
Ac < Ai OK
Eqn. 13-24
Eqn. 13-25
Eqn 13-26
Eqn. 3-27
Xi =
3.98 m
Eqn. 13-28
Eqn. 13-29
7.33 m
7.39 m
Ws =
Xs =
115,267.86 N
1.19 m
Wr =
Xr =
31,828.95 N
9.84 m
Eqn 13-31
4,934,403.12 Nm
Eqn 13-32
6,328,037.91 Nm
Eqn 13-23
Int.Pr
wint
0 kPa
0 N/m
wt
Anchorage Ratio
J = Ms / [D2 (wt (1 - 0.4Av) + wa ]
J=
5,710.04 N/m
If J < 0.785
If J > 1.54
wAB =
88024.478 N/m
Provide
15
Nos. of
36
1.72 m
=
=
=
=
240
192
36
195.43
N/mm2
N/mm2
mm
kN
Eqn 13-31
0.35
8.0 mm
1438.22 kN
F < Vs OK
( Sliding check is OK )
N=
15
Dac =
8.36 m
Eqn 3-41
OK
E.6.2.3
The overturning stability ratio for mechanically-anchored tank system excluding vertical seismic effects
shall be 2.0 or greater
0.5 D [W p + W f + W T + W fd + W g] / Ms > 2.0
where
Eqn. 6.2.3-1
D -->
Nominal diameter of Tank
Wp -->
Weight of contents of the tank
Wf -->
Weight of Tank bottom
WT -->
Weight of Tank shell, roof
=Ws+Wr
Wfd -->
Weight of tank foundation
Concrete slab size B= 9000
Dp =
500
Weight of foundation = pi()*D*B*Dp*25000
in m =
in N =
in N =
in N =
8.2
4,169,250
33,165
147,097
mm
in N =
2,898,119
Wg -->
Ms -->
in N =
in Nm =
8,563,722
0.5 D [W p + W f + W T + W fd + W g]
=
Ms =
0.5 D [W p + W f + W T + W fd + W g] / Ms =
29,715,286.37 Nm
6,328,038 Nm
4.7