You are on page 1of 34

TEMPERATURE CONTROLS

Robertshaw proprietary and confidential 2014

Refrigeration Overview

Refrigeration System Basics


Differentials
Cut-in and Cut-outs
Capillary Tubes

ETC Product Features


Cold Controls
Troubleshooting
Literature
Website
Q&A

Feature Sets
Electronic Accuracy
Wide Range (-30 to 220F)
Wide Differential Selection
Easy Installation
Easy Programming
Clear Temperature Display
No Jumpers
Contractor Preferred
Sensor up to 400 Feet
Averages Multiple Sensors
Applications
Ice Machines
Reach-In Refrigerator/Freezers
Walk-In Refrigerator/Freezers
Beverage Coolers
Condensing Units
Display Cases

It Just Makes Sense

Scientific principals are same, however


refrigeration systems are:
Operation Time 24 / 7
Defrost Cycles
Load Changes

Energy Conservation Important on A/C


Systems
However, more critical on Commercial
Refrigeration Applications

Defrost Control
Pressure Control

Temperature Control

Differentials
Narrow Differential (10F or less)
When a narrow differential is desired
Closely maintain within 5 to 6F
Typically used for air sensing applications
Wide Differential (10F or more)
Required due to swing in evaporator temperatures
between compressor ON and OFF
Household refrigerators and room air conditioners
Typically used to sense evaporator coil temperature

Cut-out mode: Differential is above set point


Output relay energizes when temperature rises to set point plus the
differential value
When temperature drops to set point, the relay de-energizes

Cut-in mode: Differential is below set point


The output relay energizes when the temperature rises to set point
When the temperature drops to setpoint minus the differential value, the
relay de-energizes

Constant cut-in controls (A30 series)


Designed for frost free refrigerators
Used in coolers and display cases

Differential cut-in controls (A12 series)


This type of control offers an adjustable differential
Rotating the dial indicator to the colder position changes the
cut-out temperature only and widens the differential

Capillary tube
The gas within the capillary tube reacts to temperature changes
Actuates the power element diaphragm to trip the toggle
mechanism

Desired Temp
(Cut-Out Mode)

Desired Temp

(Cut-In Mode)

Two Types of Cold Controls:


Constant Differential
Constant Cut-in
Applications
Water coolers
Beverage dispensers
Display cases
Constant Differential also called straight range controls
Designed for household refrigerators and freezers

Capillary-only bellows sense from the coldest exposure point


Capillary with bulb senses from the bulb only
The bulb portion of the A22 & A30 capillaries must be
mounted with tip end pointing upward within 65 of vertical
Sensing elements of A22 & A30 contain saturated vapor liquid
refrigerant and are sensitive to barometric pressure changes
Sensing elements C12 & C17 contain liquid filled bulbs for
accurate temperature control
C12 & C17 bulbs may be oriented in any position

Limited vapor-fill sensing element


Sense directly by the capillary
May be used where the desired sensing is at the coldest point
along the capillary (including the control body itself)
Entire control located where it will sense fixture temperature

Ice Machines
Display Cases
Reach-In Refrigerator/Freezers
Walk-In Refrigerator/Freezers
Beverage Coolers
Condensing Units

Electronic Accuracy
Wide Range (-30 to 220F)
Wide Differential Selection
Easy Installation
Easy Programming
Clear Temperature Display
No Jumpers
Contractor Preferred
Sensor up to 400 Feet
Averages Multiple Sensors

It Just Makes Sense

Retail store display freezers and reach-in coolers


Supermarket display cases for produce/meats
Retail store walk-in coolers and freezers
Boiler operating control (used as a thermostat)
Condenser fan cycling or staging
Cooling tower pump and fan control
Space and return air temperature control
Bulk milk coolers
Poultry houses and livestock barns

Microprocessor based electronic temperature control


Designed to provide ON and OFF control for commercial HVACR
Part Number

Voltage (AC)

Stages

Enclosure

ETC-111000-000

120/240

Standard

ETC-112000-000

24

Standard

ETC-212000-000

24

Standard

ETC-211000-000

120/240

Standard

ETC-141000-000

120/240

NEMA 4X

Ranco Electronic Temperature Control is Easier to Use!


No jumpers required
Simple programming
Johnson A419
Short cycle protection
Optional external setpoint change switch
LED lights when relay energized
Includes 3 configuration jumpers
Hard to remember programming

Johnson Controls Penn


White-Rodgers
Saganomia (Danfoss)
G.E. - Art series
Asian knock-offs
Sunne Peco
Ranco

Ice Maker

Ice Bin Level Control


Ice Harvest
Commercial Refrigeration
Household
Water Coolers

Cold Control

A and CC Series
K and RC Series
9500 Series Cold Controls
3030 Series Uni-Kits

Order Cold Control Sell Sheet


English and Spanish 150-2300

Order Commercial Refrigeration Brochure


150-2282

Mount unit to wall or flat surface


Review typical line voltage wiring diagram
Determine location of sensor
Program 4 simple steps

Instructions for wiring:


Open case by removing four screws
Connect black wire to COM
Connect white wire to 120 or 240
Attach common wire
Connect voltage to NO or NC switch
Close case and screws closed

Setting up Temperature Control is as Easy as 1-2-3-4!


1.
2.
3.
4.

Set, F or C
Set, S1 (setpoint) 70
Set, DIF1 (differential) 5
Set, C1 (cooling) or H1 (heating)

Done!

E1 appears when up or down keys are pressed


If E1 appears when no keys are being pressed, replace the control

E2 appears if control settings are not properly stored in memory


Check all settings and correct if necessary

EP appears when the probe is open, shorted or sensing a


temperature that is out of range
Check if the sensed temp is out of range.
If not, check for probe damage by comparing it to a known ambient
temp between -30 F and 220 F. Replace the probe if necessary.

EE appears if the EEPROM data has been corrupted


This condition cannot be field repaired. Replace control

CL appears if calibration mode has been entered.


Remove power to the control for at least five seconds. Reapply power.
If CL message still appears, replace control

What is the temperature range of the Ranco Electronic


Temperature Control (ETC)?
A. -50F to 0F
B. -30F to 220F
C. -30C to 220C

What voltages are available within the ETC family of products?


A. 120V AC
B. 240V AC
C. 24V AC
D. All of the above

What rule of heat transfer is mostly used in refrigeration?


A. Conduction
B. Convection
C. Radiation

32

Invensys 2014

Telephones:
Technical Service

1-800-445-8299

Technical Service Fax

1-630-260-7294

Customer Service

1-800-304-6563

Customer Service Fax

1-800-426-0804

Websites:
Uni-Line Catalog: www.Uni-Line.com
Cross Reference: www.uni-line.com/modules/xref/xrefsearch.aspx
Toolbox: www.ToolBox.InvensysControls.com

General Information for:


Robertshaw, Paragon, Ranco, Uni-Line and Publication Zone
Robertshaw, Paragon, Ranco, Uni-Line, and Make the Connection are propriety marks of Robertshaw or its subsidiaries.
All third party trademarks and service marks are the proprietary marks of their respective owners.
2014 Robertshaw. All rights reserved.

You might also like