Professional Documents
Culture Documents
For Use With Fire Rated & Non Fire Rated Exit Devices
Simultaneous Electric Latch Retraction & Dogging*
700 mA Inrush, 200 mA Continuous
Quiet Mechanical and Electric Operation
Patents # US 8,851,530
20
T E CH N O L O G Y I N N OV A T I O N S
12
CSFM, MEA
Listed
Hager
Stanley K2
IDC
TownSteel
Arrow
PHI
Falcon
Detex
Cal-Royal
PDQ
Falcon IR
SDC
Tell
Refer to page 2 to confirm compatibility of Rim, Mortise, Surface & Concealed Vertical Rod for each brand.
Application
Features
The SDC LR100 Series Electric Latch Retraction Kit enables electric
access control and dogging of mechanical exit devices. When
energized the motor retracts the exit device latch and pulls the
pushpad into the dogged (depressed) position enabling momentary or
sustained push and pull operation of the door.
The latch retraction mechanism may be activated by an access
control, remote control device or building automation system. The exit
device always provides uninhibited egress.
UL Classified for use with 3hr fire rated & non-fire rated
exit devices
Benefits
UL Listed for use with 3hr fire rated & non-fire rated exit devices
Distributor sends exit device to SDC for kit installation
SDC is not a licensee of, or affiliated or connected with any of the following companies:
Von Duprin, Yale, Corbin Russwin Dor-O-Matic, Dorma, Hager, Adams Rite, PHI, K2, Cal-Royal
Only 1 Amp SDC brand power supply required for up to 2 exit devices
Low current enables longer wire runs with smaller gauge wire
No door sequencers required for pairs of manual doors
Installs in Von Duprin non-fire rated panic device without removing
from the door
sdcsecurity.com
service@sdcsecurity.com
Price & Installation
Surface Vertical
Device
Rim Device
Ordering Information
Adams Rite
Opening
for
36"
Mortise Device
Concealed Vertical
Device
Exit Device
Design Hardware
Field
Retrofit Kit
Factory Installed
LR100ARK
LR100AR
Opening
for
36"- 48"
Exit Devices
Field
Retrofit Kit
Factory Installed
LR100DHK
LR100DH
Models
Models
Rim Mount
Rim Mount
1000R
1000V
8600 / 3600
* Note: Retracts only the latch
Detex
Exit Device
Opening
for
Field
Retrofit Kit
Factory Installed
LR100DXK
LR100DX
36"
Arrow
Opening
for
Factory Installed
LR100AWK
36" - 48"
LR100AW
Models
Rim Mount
Surface Vertical Rod
Models
Rim Mount
10 / 40 Series
20 / 50 Series
80 / 60 Series
S1250
Dorma
S1150
Opening
for
36"
Cal-Royal
Opening
for
36"
Exit Devices
Factory Installed
LR100CAK
LR100CA
Models
Rim Mount
7700 / F7700
7760 / F7760
Opening
for
36"
42" - 48"
Factory Installed
LR100DAK
LR100DA
Models
Field
Retrofit Kit
Corbin Russwin
Exit Devices
Field
Retrofit Kit
Field
Retrofit Kit
Factory Installed
LR100CRK
LR100CR
LR100CRK-42/48
LR100CR-42/48
Models
Rim Mount
9300
9400
Falcon
Opening
for
36"
Factory Installed
LR100FRK
LR100FR
Models
Rim Mount
Falcon Dor-O-Matic
Opening
for
36"
Field
Retrofit Kit
ED5200 / ED4200
Models
ED5400
Rim Mount
ED5800
LRCR1L
LRCR1R
36"
Factory Installed
LR100FAK
Rim Mount
Options
Exit Devices
LR100FA
1790
1690
Field
Retrofit Kit
Factory Installed
LR100DMK
LR100DM
Models
Rim Mount
1590
1490
Hager
Opening
for
Factory Installed
LR100H
LR100HEM
LR100HEM
Models
Sargent
Exit Devices
Opening
for
36"- 48"
Field
Retrofit Kit
Factory Installed
LR100SGK
LR100SG
Models
Rim Mount
8800
Rim Mount
4501 - Rim
8700
4501 - SVR
8600
Options
LRH1L
LRH1R
SDC
Opening
for
Opening
for
Field
Retrofit Kit
Field
Retrofit Kit
Factory Installed
LR100IDC
30" LR100IDCKEM
LR100IDCEM
36"-48"
30"
Factory Installed
LR100SDCK
LR100SDC
LR100SDCKEM
LR100SDCEM
Models
Models
Rim Mount
Rim Mount
S6100
S6200
Mortise
8620 / 8820
Mortise
S6300
S6800
Options
Options
LRIDC1L
LRIDC1R
LRSDC1L
LRSDC1R
Marshall Best
Opening
for
Exit Devices
Field
Retrofit Kit
Factory Installed
36" LR100MBSK
LR100MBS
Models
Stanley K2
Opening
for
36"- 48"
Rim Mount
Q1100/QF1100
30"
Q1200/QF1200
Models
PDQ
Field
Retrofit Kit
36"- 48 LR100PDQK
LR100K2
LR100K2KEM
LR100K2EM
QED111
QED114
Factory Installed
QED124
LR100PDQ
Options
Models
LRK2R
Rim Mount
6200R
6200V
Factory Installed
LR100K2K
Rim Mount
Exit Devices
Opening
for
Field
Retrofit Kit
Field
Retrofit Kit
36" LR100PDK
Exit Devices
Factory Installed
LR100PD
Models
Tell Mfg.
Opening
for
36"
Exit Devices
Field
Retrofit Kit
Factory Installed
LR100TEK
LR100TE
Models
Rim Mount
2101 / 2400
Rim Mount
9500
2201
9400
2801 / 2600
Rim Mount
5100
5200
Options
LRP1L
LRP2L
LRP1R
sdcsecurity.com service@sdcsecurity.com
TownSteel
Opening
for
Field
Retrofit Kit
Opening
for
Factory Installed
Von Duprin
LR100TS
LR100TSKEM
36"- 48"
LR100TSEM
30"
Models
Field
Retrofit Kit
Factory Installed
LR100VDK
LR100VD
LR100VDKEM
LR100VDEM
Models
Rim Mount
ED1100 / ED6500
Rim Mount
98/99
ED1200
9827/9927
ED1300 / ED6700
9847/9947
Mortise
9875/9975
9857/9957
Von Duprin
Opening
for
Field
Retrofit Kit
LR100VD22
LR100VDKEM22
Opening
for
Factory Installed
Yale
36"
LR100VDEM22
42" - 48"
Field
Retrofit Kit
Factory Installed
LR100YDK
LR100YD
LR100YDK-42/48
LR100YD-42/48
Models
Models
Rim Mount
22
Rim Mount
2227
7110, 7210
7120, 7220
Options
LRVD1L
Options
LRVD2L
LRY1L
LRVD1R
LRY1R
LRVD2R
LR100 series
Power Supplies
602RF 1 Amp, 12/24VDC Power Supply, UL 294 Listed
For use with up to two 24VDC devices
CSFM, MEA
Listed
DEVICE
33
32
ENDDEVICE
RAIL
32
END RAIL
18 TYP
TOUCH PAD
18 TYP
TOUCH PAD
DEVICE
28
29-1/4
ENDDEVICE
RAIL
END RAIL
8-1/2
8-1/2
LR100VD-EM
LR100VD-EM
LIT-LR100
www.sdcsecurity.com service@sdcsecurity.com
[t] 800.413.8783 805.494.0622
801 Avenida Acaso, Camarillo CA 93012 PO Box 3670, Camarillo CA 93011-3670
Each EMC provides interface and sequencing for two single or one double
automatic door. Not required for manual doors.
11-1/4
11-1/4
LR100VD
LR100VD
28
03/15