Professional Documents
Culture Documents
Model No.
FV-11VH2
FV-11VH2
FV-11VHL2
FV-11VHL2
Thank you very much for having purchased our Ventilating Fan.
I
II
III
Maintenance I (Cleaning)
Maintenance II (Replacement of lamp)
back cover
back cover
UNPACKING
Unpack and carefully remove unit from carton.
Refer to the Supplied Accessories list to verify that all parts are present.
SUPPLIED ACCESSORIES
DESCRIPTION
The Panasonic ceiling mount ventilating fans uses a sirocco fan driven by a capacitor motor. The motor is
designed to have an extended service life with reduced energy consumption. It also incorporates a
thermal cut-off for safety. The grille covering the main body is a spring-loaded, quick-release type. A
damper for preventing counterflow is provided. The blower uses a high-capacity sirocco fan developed to
reduce the noise level.
The heater for this unit is a 1400 W sheathed heater. A thermostat and thermal cut-off switch have been
added for safety in case of an abnormal temperature rise in the heater.
The lighting unit is an energy-saving, lighting device which uses two 18 W fluorescent lamps and produces
almost the same illumination as a standard 100 W incandescent lamp (FV-11VHL2).
7 5/8 (195)
Ventilating unit
2 1/2 (62)
5 (128.7)
11 1/4 (285.5)
2 1/8 (54.8)
7 3/4 (196)
7 5/8 (195)
14 (357.8)
11 7/8 (301)
11 1/4 (285.5)
13 1/4 (337.8)
11 7/8 (301)
2 1/2 (62)
1 (25)
7 3/4 (196)
DIMENSIONS
19 1/2 (497)
16 (407)
18 1/8 (460)
5 (128.7)
16 (407)
19 1/2 (497)
18 1/8 (460)
SPECIFICATIONS
Noise
Vent (0.1" WG)
(cfm)
Exhaust &
Circulation
29.5
Vent
(sone)
650
0.6
15.6
(7.1)
720
0.7
17.8
(8.1)
1540
WIRING DIAGRAM
White
Heater
(1400W)
Fuse Thermal
cut-off
o
o
Black (20A) (230 F (110 C))
Black
Motor(C) Red
White
PCB
Electronic
ballast
White
White
Ventilating fan unit
Red
Motor(V) White
Black
Heater
(1400W)
Thermostat
(140oF (60oC))
Thermostato
(140oF (60C))
Capacitor
Fluorescent lamp
Motor(V)
Black
White
Black
White
Black
ON
ON
White
OFF
ON
Black
ON
OFF
Black
White
White
Black
Black
Junction box
Night lamp
Junction box
Green
Power Supply
AC120V 60Hz
Power Supply
AC120V 60Hz
OFF
Switch(not
included)
OFF
Switch(not
included)
Switch(not
included)
Switch(not
included)
OFF
ON
OFF
ON
Switch(not
included)
Green
Earth ground
Black
Black
PCB
Thermal
cut-off
(230oF (110oC))
White
Black
Motor(C) Red
Lighting unit
Fuse
(3.15A)
Suspension
bracket
Fan body
Suspension
bracket
Tape
Suspension
bracket
Fan body
Fig.2-1
Suspension
bracket
Fig.1
Suspension
Suspension bracket
bracket
Fig.2-2
Suspension
bracket
Fan body
Joists
Joist
Fig.2-3
Fan body
Fig.3
2 Long screws
(ST4.2X20)
2 Screw (ST4.2X8)
Suspension bracket
Joist
Screw
(ST4.2X12)
Suspension bracket
Fig.4-1
Screw
(ST4.2X12)
(Fig.3)
Joist
Fig.4-2
Screw driver
Junction box
plate
Lighting cord
Screw
Hook
Fig.5
Black to black
Junction box plate White to white
White to white
Black to black
Green to green
Wire nut
Black to black
Black to black
Junction box
White to white
Conduit
Fig.6
Circular duct
Conduit
Duct tape
or clamps
Fan body
Joist
Fig.7
9)
17 3/8 (441)
5/8
(31
12
Night lamp
Fluorescent lamp
Slot
(Fig.10)
Fig.8
Mounting spring
Correct
Incorrect
Grille
Switch
labels
Fig.9
Switch
labels
Fig.10
INSTALLATION
Suspension
bracket
Fan body
Suspension
bracket
Suspension
bracket
Fig.11
Joists
Adaptor
Fan body
Junction box
Suspension bracket
Fig.12
Fig.12
INSTALLATION
Fig.13, Fig.14
Joist
2 Long screws
(ST4.2X20)
Fig.13
2-Screw
(ST4.2X12)
Fig.14
4 Long screws
(ST4.2X20)
Joist
Fig.14
INSTALLATION
Ceiling joist
11 3
/8 (
Header
Ceiling joist
290
)
/8
19 7
(505
Adaptor
(Fig.15, Fig.16)
Fan body
Fig.15
Adaptor
Circular
duct
Fig.16
MAINTENANCE
(CLEANING)
Slot
Mounting spring
Gloves
Grille
1
1
2
Fig.17
Fig.17
Fig.18
Fig.18
Fig.19
Vacuum cleaner
Fig.19
Fig.20
5. Replace grille.
Fig.20
MAINTENANCE
(REPLACEMENT OF LAMP)
Night lamp
Fluorescent lamp
Fig.21
Fluorescent lamp
Fig.22
Insulation
Foil tape tightly covers all metal
duct joints (glue PVC joints).
Fig.23
11VH24200