You are on page 1of 17

EPON vs.

GPON
A Comparative Study

November 22, 2004

EPON vs. GPON

Table Of Contents

INTRODUCTION ...............................................................................................................................................3

EPON AND GPON OVERVIEW ......................................................................................................................4


2.1

PON CONCEPTS..............................................................................................................................................5

2.1.1

Layering and Multiplexing ....................................................................................................................5

2.1.2

Media Access .........................................................................................................................................7

2.1.3

ONT Discovery & Activation .................................................................................................................8

2.1.4

Encryption .............................................................................................................................................9

2.1.5

Protection Switching..............................................................................................................................9

2.1.6

PHY Related Features ...........................................................................................................................9

2.2

DEPLOYMENT ASPECTS ................................................................................................................................10

2.2.1

Quality of Service ................................................................................................................................10

2.2.2

Services................................................................................................................................................10

2.2.3

Bandwidth and Efficiency ....................................................................................................................11

2.2.4

Migration from BPON .........................................................................................................................12

2.2.5

Network Management..........................................................................................................................12

2.2.6

OSS Integration Options......................................................................................................................13

2.2.7

Network Uplink Options ......................................................................................................................13

2.3

PON DEVELOPMENTS...................................................................................................................................13

CONCLUSIONS................................................................................................................................................15

APPENDIX ........................................................................................................................................................17

Page 2 of 17

EPON vs. GPON

1 Introduction
Background
PON standardization activities have been going on for about ten years. With the continuing availability of more
advanced technology, PON line rates have increased from 155Mbps up to 2.4Gbps. The timeline is shown in Fig. 1.
FSAN starts first formal PON
activity. 155Mbps APON ITU G.983
series

Enhanced to BPON 622/155Mbps


with 3rd lambda, protection and DBA

EPON Ratified by IEEE

ITU approves GPON

1995

1996

1997

1998

1999

2000

2001

2002

2003

2004

FSAN starts GPON work G.984


series = extension of G.983 series,
up to 2.4Gbps

EFM starts work on 802.3ah incl


EPON

Figure 1:

PON standardization timetable

With the explosion of the Internet, it didnt take too long before ATM-based BPON systems proved to be very
inefficient, as the vast majority of traffic through the access network consists of large, variable-sized IP frames.
This created the opportunity for the development of the pure-Ethernet based EPON, taking advantage of emerging
QOS-aware GigE switches and cost-effective integration with other Ethernet equipment. Ethernet has proven over
time to be the ideal transport for IP traffic.
EPON and GPON
As a result, the IEEE 802.3 tasked the 802.3ah Ethernet in the First Mile work group with the development of
standards for point-to-point and point-to-multipoint access networks, the latter specifying Ethernet PONs. EPON is
currently part of standard Ethernet.
Development of the Gigabit-capable Passive Optical Network (GPON) standard (G.984 series) really started after
proposals by FSAN members (Quantum Bridge et. al) for a protocol-independent ATM/Ethernet Gbps PON
solution were not very popular within the IEEE 802.3ah work group. FSAN then decided to continue this as a
different competing standard in the ITU.
EPON and GPON both draw heavily from G.983, the BPON standard, when it comes to general concepts that work
well (PON operation, Optical Distribution Network (ODN), wavelength plan, and application). They both offer their
own version of enhancements in order to better accommodate variable sized IP/Ethernet frames at Gbps rates.
Deployments
Today, BPON has gained a decent level of maturity representing about a quarter of the over 1.5 million FTTH
(data-only) lines deployed in Japan so far. Maturity and stability may have motivated SBC, Verizon, and Bellsouth
to commit to BPON for their multi-$Billion FTTP deployments, in spite of its obvious shortcomings.
In the mean time, however, as a clear testimony to the future of PON, NTT is already upgrading and further
expanding their FTTH network with EPON, not GPON. This is the common trend elsewhere in Asia. EPON is
clearly taking off!

Page 3 of 17

EPON vs. GPON

This begs the question: Do we really need GPON next to EPON? In order to answer this question we will take a
closer look at these two flavors, and compare their different approaches on technical and practical merits. We will
show that EPON represents a far more elegant solution that is well in line with the evolution of the rest of the
network towards an all-IP/Ethernet strategy.

2 EPON and GPON Overview


As pointed out earlier, EPON and GPON both draw heavily from the BPON specification. This is evident in the
table in Appendix A. In this section we take a closer look at the areas where they differ.
The following table shows the key features of EPON and GPON.
EPON and GPON Features
EPON

GPON

Service

Full service, triple-play + RF video

Same

Layering and
Multiplexing

Native Ethernet (includes TDM)

ATM and Generic Frame


(including Ethernet and
TDM )

Media Access

TDMA via granting -- derived from BPON

Equivalent

ONT Discovery and


Activation

Auto-discovery of new ONTs

Equivalent

Comments

(see sec 2.1)

PHY related features:

Number of
branches

Wavelength
arrangement

Spec: > 16; 64 feasible


# logical splits not specified
Downstream:
1480-1500 nm
Upstream: 12601360 nm

Capable of multiplexing
downstream for video
distribution (1550-1560 nm)

Max 64 at the PHY


Max 128 at the TC layer
(logical splits)

Same

(BPON)

ODN class
classification

Class A(5-20 dB), 10 km; Class B(10-25 dB), 20 km

Class A; Class B; Class


C (15-30 dB), 20 km

GPON adds Class C

FEC (optional)

Reed Solomon

Same

FEC (forward error correction) reduces an


optical module cost, and aims to ease Tx power
and Rx optical sensitivity

Encryption
(optional)

AES-128 on Ethernet payload planned

AES-128 on ATM and


GEM frame payload

Equivalent strategy, slightly different scope

Down: 1.2, 2.4 Gbps

Bit rate

Other (optional)

Downstream: 1 Gbps
Upstream: 1 Gbps

Up: 155 Mbps, 622


Mbps, 1.2 Gbps, 2.4
Gbps

OLT informs ONT of receiver stabilization time at


discovery

ONT optical output


power leveling

In GPON, the ONT optical output can be


adjusted in 2 steps to relieve automatic power
distribution (APD) tolerance of OLT.

The gray areas indicate similarities.


The strategy of GPON is to continue to support legacy ATM as in BPON, but additionally support Gbps rates,
better encryption, as well as a new frame-orientated mode that can better accommodate native TDM and variable
sized IP/Ethernet frames. The justification for the continued support of ATM is often explained as serving the
need for backhauling of first-generation DSL traffic. This remains to be seen, considering that todays IP DSLAMs
are all Ethernet based.

Page 4 of 17

EPON vs. GPON

2.1 PON Concepts


This section presents several key concepts and how they have been addressed in EPON and GPON. Since these two
PON flavors really have a lot in common, we focus on conceptual differences in the following areas.
1.

Layering and Multiplexing

2.

Media Access

3.

ONT Discovery and Activation

4.

Encryption

5.

Protection Switching

2.1.1 Layering and Multiplexing


In EPON, Ethernet frames are carried in their native format on the PON. This greatly simplifies the layering model
and the associated management. Services are all mapped over Ethernet (directly or via IP).
In order to accomplish the same in GPON, two layers of encapsulation are required. First, TDM and Ethernet
frames are wrapped into GTC Encapsulation Method (GEM) frames, which have a GFP-like format (derived from
Generic Frame Procedure ITU G.7401). Secondly, ATM and GEM frames are both encapsulated into GTC frames
that are finally transported over the PON. See the figure below.

Layer 5+

T1/E1
TDM

POTS

Data

Video

Layer 5+

Layer 4

TCP+UDP etc

Layer 4

Layer 3

IP

Layer 3

Various
services

T1/E1
TDM

POTS

Layer 2

IP
Ethernet

ATM cell

GEM frame

Ethernet frame

GTC TC frame
MAC layer

Layer 1

Video

TCP+UDP etc

AAL 1/2/5

Layer 2

Data

PON-PHY

GTC sub-layer
Layer 1

PON-PHY

GPON Layering

EPON Layering

Figure 2:

EPON vs. GPON Layering

The main purpose of the GEM frame is to provide a frame-oriented service, as an alternative to ATM, in order to
efficiently accommodate Ethernet and TDM frames. Both ATM and GEM modes are mandatory at the OLT, but an
ONT can be configured to support either one, or both.
As an evolution step from the ATM-based BPON, this may sound like a big improvement. However, when
compared to the simple EPON model, it becomes clear that the GEM/GTC encapsulation and inclusion of ATM are
adding unnecessary complexity to solve the same problem. The different transport schemes are illustrated in Figure
3.

Page 5 of 17

EPON vs. GPON

uplink

ingress

transport

OLT

ODN

ONU

Service
adaptation

Service
adaptation
IP/Ethernet

IP/ATM

ATM
XC

ATM
XC

TDM

TDM

ATM

BPON

Service
adaptation

Service
adaptation
?

ATM & GEM


XC

TDM

ATM & GEM


XC
TDM

GEM

ATM
Ethernet

IP/Ethernet
GTC frame

GFP/SONET?

Ethernet

TDM

GPON

Service
adaptation

Service
adaptation
TDM

TDM

Ethernet
XC

IP/Ethernet

Ethernet
XC

IP/Ethernet

Ethernet

TDM/
Ethernet

EPON

Figure 3:

Frame Transport in BPON, GPON, and EPON

EPON clearly offers a much simpler and more straightforward solution than GPON. The support of ATM
and the double encapsulation of GPON serve no real benefit over a pure Ethernet transport scheme.

2.1.1.1 TDM Support


In both EPON and GPON systems, TDM is supported by assigning sufficient network resources to avoid
unnecessary blocking and latency, by periodic scheduling of upstream bandwidth, and by distributing the CO clock
downstream throughout the PON in order to avoid jitter and drifting.
The Service Adaptation block in Figure 3 is responsible for extracting and transferring native TDM from/to the
associated frames. In EPON these are standard Ethernet frames, while in GPON this is done via GEM frames.
In EPON systems the clock is commonly embedded in the downstream signal, which allows an 8kHz clock to be
recovered at the ONT for synchronization. In a similar way, this is achieved in GPON by transmitting a marker
with downstream GTC frames at 125 sec boundaries.

2.1.1.2 Control messages


EPON is managed like any other Ethernet switch via SNMP through IETF MIBs. Additional control messages are
Multi-Point Control Protocol (MPCP) GATEs/REPORTs for BW granting, as well as EFM OAM messages.
MPCP and EFM OAM frames are multiplexed with regular Ethernet traffic

Page 6 of 17

EPON vs. GPON

In GPON there are three different types of control messages: OMCI, OAM, and PLOAM. Their roles are shown in
the table below. In either case, REPORTs are transported upstream as payload traffic.
Control Messages in EPON and GPON
Control function

EPON

GPON

Provisioning of ONT service defining layers above L2

IETF MIB / SNMP

OMCI (Ethernet or ATM)

BW granting, Encryption key switching, and DBA

MPCP (higher layer for encryption key)

Embedded OAM (Header overhead)

Auto discovery, and all other PMD and GTC mgt info.

MPCP and EFM OAM

PLOAM (ATM)

2.1.1.3 Multiplexing architecture


The multiplexing architecture in EPON is based on the point-to-point emulation concept, where the OLT contains
multiple MACs, each having a 1:1 relationship with an ONT off the PON. This is represented by the Logical Link
ID (LLID), which is used for addressing. The figure below illustrates the roles of LLIDs in point-to-point
emulation. Notice the significance of the bridge at the OLT in this model, which is not present in GPON.

Standard 802.1 Bridge

MAC

MAC

MAC

MAC

MAC

MAC

MAC

LLID
OLT

LLID
MAC

MAC

MAC

MAC

MAC

MAC

MAC

ONT

Figure 4:

Point-to-Point Emulation in EPON

An ONT is identified by the LLID. In addition, the VLAN_ID can be used for further addressing. A given VLAN
is identified as LLIDVLAN_ID. In the downstream direction, the OLT attaches the LLID to the preamble of
frames, which is used to identify the right port on the bridge.
Similar to the LLID, GPON uses a parameter called T-CONT to address ONTs. In the ATM mode, a given VC is
addressed via ONT_IDT-CONTVPI/VCI. In the GEM mode, a port can be identified via ONT_IDTCONTPort_ID.
Both the LLID and T-CONT provide a form of point-to-point emulation, except that GPON has no relationship to
802.1 bridge, and hence bridging has to be achieved upstream of the OLT.

2.1.2 Media Access


2.1.2.1 Granting / Resource Allocation
In EPON, grants are sent per-LLID, as separate MAC-Control client frames (GATEs), in-between regular Ethernet
frames. Each grant specifies an upstream transmission opportunity for a given ONU via {LLID+Start+Length}

Page 7 of 17

EPON vs. GPON

Similarly, GPON grants per T-CONT. Grants are carried in the downstream frame header overhead, via a map that
holds multiple grants specifying {Alloc-ID+Start+End} for each granted upstream Window (timeslot). The two
different schemes are shown in the figure below.
Downstream
Frame header (PBCd)
Downstream

LLID
1

Start
100

Length

LLID

200

Start
400

Length
100

LLID
3

Start
520

Length
80

Payload

US BW Map

Alloc-ID

Start

End

Alloc-ID

Start

End

Alloc-ID

Start

End

100

300

400

500

520

600

Upstream
LLID 1
(ONU1)

LLID 2
(ONU2)

LLID 3
(ONU3)

T-CONT 1
(ONU1)

EPON

Figure 5:

T-CONT 2
(ONU2)

T-CONT 3
(ONU3)

GPON

EPON And GPON Media Access Control

2.1.2.2 Dynamic Bandwidth Allocation


Dynamic Bandwidth Allocation (DBA) refers to an optional flexible upstream timeslot assignment mechanism used
in a PON. It allows a system to assign upstream timeslots in real-time, based on the instantaneous demand of a
given ONT, and hence use the upstream bandwidth more efficiently. In a typical FTTH deployment today where
there is ample upstream bandwidth, DBA is not very effective since traffic patterns are still asymmetric and
upstream bandwidth demands tend to be relatively low. However, in situations where the upstream demand is
relatively high (e.g., FTTB, or emerging gaming services), DBA could be useful.
DBA is optional in EPON, and out of scope. The right hooks are supported, however, allowing ONTs to send
REPORT messages including multiple 802.1p queue states, but its up to the scheduler at the OLT whether / how to
interpret this information.
GPON uses a very similar scheme, but there the DBA is part of the standard. Elements of the two schemes are
outlined in the table below.
DBA Elements in GPON and EPON
GPON DBA

EPON DBA

Granting unit

GTC Overhead

MPCP GATE frame

Control unit

T-CONT

LLID

Identification of control unit

Alloc_ID

LLID

Reporting unit

ATM: ATM cell / GEM: fixed length block

MPCP REPORT frame

Reporting mechanism

Embedded OAM

Separate REPORT frame

Negotiation procedure

GPON OMCI

N/a

2.1.3 ONT Discovery & Activation


EPON supports a discovery mechanism that allows the OLT to automatically detect a newly added ONT, learn its
MAC Address, assign an LLID, and activate the ONT. At this point it is up to the provisioning application to
configure it with appropriate user bandwidth and other subscriber parameters.
Standard EPON does not require the ONT Serial Number for authentication; however, higher-level authentication
schemes can do so.
GPON uses the Serial Number for ONT authentication. This can be either pre-provisioned, or discovered by the
OLT. Once the Serial Number is detected, an ONT-ID is assigned, and the ONT is activated.

Page 8 of 17

EPON vs. GPON

2.1.4 Encryption
Both EPON and GPON have endorsed 128-bit Advanced Encryption Standard (AES) encryption. 128-bit keys
means that there are 3.4 x 1038 possible keys, i.e., very strong encryption.
The GPON standard already includes this scheme and encrypts the GEM payload, which means that Ethernet frames
and TDM data are completely encrypted. Key management messages are exchanged via PLOAM cells.
EPON is expected to include this in the standard in 2005, encrypting the Ethernet payload. This includes complete
IP payloads as well as TDM data. A group key protocol is additionally required for multicasting (e.g., IPTV).
Details, including key management are still under discussion.
Notice that some may consider the GPON approach stronger than that of EPON, citing concerns about exposing
MAC addresses over the PON link. However the true severity of this threat has always been a controversial topic.

2.1.5 Protection Switching


GPON survivability features are derived from G.983, so there is the benefit of a standardized scheme. Upon
detecting downstream signal loss, an ONT and sends a Loss of Window (LOW) alarm to the OLT. As a result,
either the OLT switches all ONTs to the protection fiber, or the OLT switches itself.
Protection switching is out of scope for EPON. Vendors offer various proprietary solutions, and interoperability
can potentially be an obstacle in deployments where multi-vendor solutions are required by the service providers.

2.1.6 PHY Related Features


2.1.6.1 Physical Medium Dependent layer (PMD)
EPON and GPON both support the same wavelength plan as BPON, i.e., Upstream {1260-1360 nm}, Downstream
{1480-1500 nm} and Video distribution {1550-1560 nm}.
Three different PMD classes, defined in G.982, are specified for transceivers in GPON. Key parameters are shown
in the table below, compared with EPON . <Review this table w/Ketan>
ODN Classes
GPON
Class A

Class B

Class C

EPON

Rates

155, 622Mbps; 1.25Gbps

1.25Gbps

Reach

10km

10km

Splits

16

16

OLT Rx sensitivity

ONT Tx on/off time

16ns

512ns

Rates

155, 622Mbps; 1.25Gbps

1.25Gbps

Reach

20km

20km

Splits

32

32

OLT Rx sensitivity

ONT Tx on/off time

16ns

512ns

Rates

155, 622Mbps; 1.25Gbps 2.4Gbps

N/S

Reach

> 20km

N/S

Splits

64

N/S

OLT Rx sensitivity

N/S

ONT Tx on/off time

16ns

N/S

Note
EPON 1000PX-10

EPON 1000PX-20

Page 9 of 17

EPON vs. GPON

2.1.6.2 Line Coding


As part of standard Ethernet, EPON uses 8B10B line coding for DC balancing to allow reasonable clock recovery.
This implies an overhead of 20% of the 1.25Gbps line rate, i.e., a maximum capacity of 1Gbps
GPON uses NRZ line coding, and frames are scrambled using a frame-synchronous scrambling polynomial. As a
result, there is no line-coding overhead, and the maximum available capacity is 1.25Gbps.

2.1.6.3 Power Leveling


GPON supports an optional power leveling mechanism, where the OLT can instruct the ONT to change its power
level to one of three states (Normal, Normal-3dB, or Normal-6dB), based on the measured levels.
In EPON systems only one state is supported. Notice that during EPON auto discovery, the OLT informs the ONTs
of its synchronization time, allowing ONTs to adjust their upstream transmission timing accordingly.

2.2 Deployment Aspects


In order to further understand the differences between GPON and EPON, we next take a look at how they fare when
it comes to actual deployment. The following aspects are briefly addressed:

Quality of Service (QoS)

Bandwidth and efficiency

Network management

Services

Migration from BPON

OSS integration options


Network uplink options

2.2.1 Quality of Service


Traditionally, BPON solutions were often referred to as having better QoS features than EPON, based on the fact
that historically ATM-based solutions enjoyed a set of QoS features that were not supported in Ethernet-based ones.
Not anymore, though, as switches available today use common QoS engines and offer similar features. A good
example is the fact that GPON, which was designed as a superset of BPON, uses GEM cross-connects for TDM
services, not ATM. In a very similar way, EPON systems utilize state-of-the-art QoS-aware Ethernet switches.
At the end, effective QoS is really a product of systems architecture fundamentals, not the PON flavor.

2.2.2 Services
It is sometimes claimed that EPON is only appropriate for data-only services and GPON for triple-play. The reality
is however, that today EPON-based systems are being deployed worldwide, successfully delivering carrier-grade
triple-play services.
The EPON protocol was deliberately designed to allow the simultaneous support of loss- and delay-sensitive traffic.
Combining this with versatile QoS-aware switches and proper system architecture techniques (including VLANs,
queue design, priority-based scheduling, etc) results in powerful solutions, capable of transporting any type of
service (IP Data, TDM, POTS, VOIP, IPTV, RF Video). In fact, when it comes to certain IP/Ethernet services, it
turns out that GPON is the one that fall short, as is shown below.

Page 10 of 17

EPON vs. GPON

2.2.2.1 IPTV support


IPTV consists of Video on Demand (VOD) and Switched Digital Video (SDV). With VOD, each IP stream is
viewed by one viewer, while with SDV multiple users can view a single IP stream.
VOD relies on IP Unicast and SDV on IP Multicast. Both require high bandwidth to minimize frame loss, and fast
system response to minimize channel change times.
IPTV SDV solutions that utilize IGMP work very well over the broadcast topology of a PON. A key benefit is its
inherent single-copy broadcast capability, resulting in bandwidth consumption as a function of channels, rather than
the number of viewers. However, the overall performance scalability of the service relies heavily on the
multicasting and broadcast capabilities of the underlying transport network.
This is where Ethernet-based networks have a strong advantage, as these features are inherent to Ethernet
switches. In an EPON system, additional efficiency can be achieved by implementing filtering and proxy
functions at strategic points within the PON subnetwork.
Even though GPON systems are designed to transport Ethernet frames efficiently, they cannot benefit from the
multicast advantages of Ethernet, since they do not switch Ethernet traffic (but rather GEM and/or ATM frames).

2.2.2.2 Bridging
Since in the GPON architecture the cross-connect at the OLT is not an Ethernet switch, GPON cannot support
standard Bridging, which can be of interest in FTTB deployments. Some form of GEM-bridging could probably
be implemented that allows port-port bridging (TDM or Ethernet), but this would not be very inefficient.
In order to support standard bridging, there would be the need for an Ethernet switch upstream of the OLT crossconnect, either in an aggregation point in the same chassis, or externally.
Bridging is a standard feature of EPON systems, supported via point-to-point emulation (see figure 4).

2.2.2.3 Transparent LAN Services (TLS)


TLS is another popular business application that is not directly supported by a standard GPON system, as it is
achieved via VLAN tunneling (Q-in-Q) in Ethernet switches. Without these in the OLT chassis, one would need to
use external Ethernet switches in order to achieve the same result.
TLS is commonly supported in EPON systems implemented in the Ethernet switches at the OLT and ONTs.

2.2.3 Bandwidth and Efficiency


2.2.3.1 Bandwidth
Probably the most heralded benefit of GPON is the fact that it is specified to scale up to 2.448 Gbps in both the
upstream and downstream directions. Rates are shown in the table below.
GPON Rates
Downstream (Mbps)

Upstream (Mbps)

1,244

155.52; 622.08; 1,24416

2,488

155.52; 622.08; 1,24416; 2.48832

One apparent advantage of the multi-tiered bandwidth scheme is that it can be configured for 1.2 or 2.4 Gbps
downstream and 622 Mbps upstream, and take advantage of lower cost lasers at the ONT.
Today, however, rates of 1.2Gbps/622Mbs for downstream vs. upstream are a more realistic target (similar to
extended BPON), sharing similar technology with EPON. <any comments on the cost of 1.2G/622M vs. 1G/1G?>

Page 11 of 17

EPON vs. GPON

Notice also that 2.4 Gbps is not a common rate, and lacks volumes to draw from in order to drive down ONT
transceiver costs. Upstream rates higher than 622Mbps are also not economical due to mode partition noise, until
narrow spectral width FP lasers become economical.

2.2.3.2 Efficiency
Due to its use of NRZ scrambling as opposed to 8B10B encoding, GPON does not pay the 20% overhead penalty as
in Ethernet. This makes it appear even more attractive, with efficiency potentially in the upper 90% (of 1.244
Gbps). This is often contrasted to EPON, which is frequently incorrectly claimed to be only 50% efficient.
Efficiency has to be considered in both directions of a PON. Each PON protocol introduces its own overhead in
either direction. The downstream efficiency is significantly more important because of the asymmetric nature of
PON bandwidth usage. Notice e.g., that for data services in a typical FTTH deployment at least 40% of the
upstream BW consists of a low load of small packets (internet TCP ACKs). In addition, one has to take in
consideration the actual upstream demand.
PON efficiency is a function of protocol encapsulation and scheduling efficiencies. In the downstream direction,
the impact of either one is relatively low.
EPON efficiency can be shown [3] to reach theoretically up to about 72% (downstream) and 68% (upstream) of
1.25Gps (i.e., about 900Mbps/850Mbps) while GPON in GEM mode can achieve about 95% of 1.25Gbps in either
direction [4].
In practice, upstream efficiency values are often much lower due to vendors design choices and component
selection. Often, however, a few 100s Mbps upstream is sufficient for standard FTTH applications, especially
when DBA is used. Of course, what actually matters is the remaining usable bandwidth, and whether or not it is
sufficient for the intended PON application (e.g., FTTH, 32 splits, triple play, HDTV or regular IPTV, etc.).

2.2.4 Migration from BPON


Since BPON, GPON and EPON are based on different technologies, their OLTs and ONTs are not interoperable.
Migration from BPON therefore requires replacing the OLT and all associated ONTs, i.e., significant truck rolls.
The good news is that the common ODN in-between remains untouched, which is one of the main attractive
features of FTTP.
The least painful migration scenario is probably a same-vendor one, i.e., replacing BPON OLT blades and their
associated ONTs with GPON or EPON ones off the same chassis. A clever BPONGPON strategy is what many
BPON vendors are selling today; it validates the investment in outdated BPON gear, creates a future for GPON, and
at the same time locks in the customer.
For service providers with large investments in their ATM-based core networks, GPON may initially have some
appeal because of its support of ATM. However, notice that existing ATM core networks are quickly running out
of capacity and are simply too expensive, and too complicated to manage, and are being replaced by GigE systems.
On the access side, most operators are installing IP DSLAMs today that support GigE uplinks, eliminating the need
for ATM altogether.
Migration to EPON, not GPON, as a true IP/Ethernet solution, is therefore a far more realistic and futureproof scenario, consistent with the evolution of the rest of the network.

2.2.5 Network Management


Conventional Ethernet, traditionally used exclusively in enterprise environments, has historically been relatively
weak in areas of network management that are important to large-scale subscriber access networks. Key areas of
concern have been:
Limited performance monitoring and servicelevel agreement (SLA) assurance metrics
Limited or non-existent diagnostics, fault management and isolation capabilities
Lack of a clear service demarcation point

Page 12 of 17

EPON vs. GPON

Non-standard provisioning and control architectures


Incompatible network management interfaces
These areas have been addressed with the introduction of Ethernet in the First Mile (802.3ah), and continue to be
the focus in different standards organizations. EPON system vendors have been successful in filling any remaining
gaps with innovative solutions.
These areas should also be reasonably well covered in GPON, as it inherits some of the ATM functionality and was
designed with the input of a few service providers.
For an EPON system, management of PON operation and OLT/ONT interoperability are defined through EFM
OAM and IETF MIBs. Equivalently, GPON has outlined its management capabilities through a series of OMCI
specs.
Because of its inherent Ethernet simplicity and collapsed layering model, management should be much
simpler for EPON than GPON. Regardless of the flavor of PON, the rest of the system is commonly managed
through traditional telecom system models using MIBs that include management functions for equipment, service
cards, services, alarms, PM data, etc. (ITU, Telcordia, ANSI, ETSI, etc)

2.2.6 OSS Integration Options


OSS options vary widely. However, a common trend is that many operators are updating their OSS software in
favor of next generation 3rd party software. Common choices are Micromuse Netcool for assurance and Syndesis
Netprovision for inventory and provisioning. These systems are very flexible to customize, and typically well
positioned for supporting IP/Ethernet based systems and services, as they have been for the many routers and
switches in todays carrier networks.
EPON management is added as an extension to the already widely supported Ethernet MIB. Integrating an
EPON system is therefore a very reasonable effort, significantly easier than GPON.

2.2.7 Network Uplink Options


Network uplink options are similar for EPON and GPON. Once switched at the OLT, services are adapted to
the familiar service interfaces (DS3, T1E1, ATM, SONET/SDH, GigE, 100BT, etc).
An area where GPONs GEM format is sometimes said to offer some benefit is that, because of its similarity to
GFP, GPON vendors could design the OLT to pass native GFP frames to the uplink via SONET/SDH payloads (see
figure 3). This could help accomplish transparent trunking of Ethernet or TDM payloads. Of course, TLS is a more
elegant way of doing this, as supported in EPON systems.

2.3 PON Developments


Today, there are about twice as many BPON vendors than there are EPON ones (see table below). About half of the
BPON vendors have indicated they are developing GPON products (although they dont seem to be in a rush); only
two companies have released GPON products today. The table below shows the state of PON developments of
over 30 vendors today.
Notice how this growing pool of PON vendors can roughly be divided into broad camps:
-

Early generation, sub-rate APON and EPON systems by Japanese vendors (e.g., Fujitsu and Fujikura)

BPON an GPON systems by FSAN members (Alcatel, Quantum Bridge (now Motorola), Hitachi)

EPON systems by Asian or Asian-focused vendors (Hitachi, Sumitomo, UTStarcom)

Traditional DSLAM, DLC etc. vendors integration BPON/GPON blades Lucent, Calix, AFC etc.

Pioneering private companies with mostly US-focus (Alloptic, OSI, Wave7, Flexlight)

Page 13 of 17

EPON vs. GPON

Product-wise, the common trend is still: Triple play in the North America; data-only in Asia.
PON Vendors
Loc.

BPON

GPON

EPON

USA

(incl. Marconi product) Embarking on large BPON deployment in 2005 (Verizon)

Alcatel

France

Embarking on large BPON deployment in 2005 (SBC)

Alloptic

USA

C-COR reselling

Calix

USA

Blade in C7

Carrier Access

USA

ONT vendor

Ciena

USA

(Old Catena Networks BPON product) Working on a GPON blade

ECI Telecom

Israel

Nortel reselling

Entrisphere

USA

ONT vendor; Partnering with Fujitsu

Fiberhome Networks

China

Teknovus chipset

Flexlight

Israel

Key author of GPON spec

Fujikura / Alcoa

Japan

S*

Half-Gig EPON

Fujitsu

Japan

155Mbps APON product did fairly well for NTT

GW Technologies

China

Hitachi

Japan

iamba

Israel

LG

Korea

Lucent

USA

(S)

GPON blade for Stinger planned; Reselling Salira EPON

Mitsubishi

Japan

S*/L

Working with Passave awarded NTT contract

Motorola (QB)

USA

L?

Nayna

USA

NEC

Japan

S*

Oki

Japan

Oki+Fujitsu venture OFN working with Centillium awarded NTT contract

Optical Solutions

USA

CWDM PON shares GPON market with Flexlight today

Salira

USA

Teknovus chipset; Lucent reselling

Samsung

Korea

S?

Doing something with ETRI

Siemens

Germany

Sumitomo

Japan

S*/L

Terawave

USA

L?

L?

TTS Communications

USA

Hybrid PON?

UTStarcom

USA

Working With Passave / huge presence in China

Vinci Systems

USA

ONT only AnyPON

Wave7

USA

S*/L

Zhone

USA

AFC

*) lower-rate pre-standard version

Comments

200k data-only ONTs deployed by NTT . Partners with Wave7 for triple-play ONT.

Co-author of GPON spec (with Flexlight)

S*

Broadlight chipset
Working with Passave
Active participant in 802.3ah WG

Apparently upgrading to EFM compliant system.


(old NEC eLumnant BPON)

<Q: what about Chinas ZTE and Huawei?>

Page 14 of 17

EPON vs. GPON

Notice that AFC, ECI, Entrisphere, Calix, Siemens, Zhone and Ciena are currently all developing BPON systems
using Broadlights chipset, which includes 1.25Gbps/622Mbps extended BPON rates as well as pin-compatible
GPON options. This provides them with a built-in migration path to GPON.

3 Conclusions
Key advantages vs. disadvantages of GPON and EPON are compared in the table below.
GPON vs. EPON
Advantages
GPON

-Can be operated at different rates w/different transceivers


-Higher theoretical BW, up to 2x that of EPON
-Can be configured in asymmetric fashion and take advantage of lower
ONT laser costs, e.g., 1.2G/622M or 2.4G/622M
-Encrypts the full payload, ie., full Ethernet frames -- no exposed MAC
addresses

Disadvantages
-Complex layering model Ethernet/GEM/GTC
encapsulation means complex management
-More expensive at comparable rates as EPON
-Transceivers at 2.4Gbps rates are expensive today,
no volumes
-upstream BW limited to 622Mbps today

Better chances for interoperability


-Standard supports TDM
-Standard ONT service-level management
EPON

-Native transport of Ethernet frames

Mostly interoperability obstacles:

-Simple and familiar, lower cost management

-Non-standard service-level interoperability

-Benefits from true Ethernet switching

- non-standard TDM

-Fully compatible with IP

-non-standard encryption

-Supports TLS

-non-standard protection switching

-Broadcast, Multicast --IGMP


-IGMP support means better support for IPTV with high scalability
-lower costs optics due to relaxed timing parameters

In conclusion, GPON can be seen as a me-too specification that duplicates EPON functionality, but than in a
rather complex way. The actual practical need for the GPON standard in addition to EPON remains questionable.
Notice the following observations:

Ethernet can be transported in its native format and support all services very well, as demonstrated with
carrier-grade TDM suport in EPON
ATM traffic is insignificant or not-existent in todays access networks, adding unnecessary complication to
GPON
GPON and EPON are equally capable of providing the QoS capabilities required for triple play service
differentiation

I.e., EPON is not limited to data-only services, but can support triple-play services as well as GPON

Even though GPON is capable of transporting Ethernet traffic, it lacks several key capabilities inherent to pure
Ethernet switches. EPON is more appropriate for IP/Ethernet services:

Page 15 of 17

EPON vs. GPON

EPON solutions are more popular with service providers where IPTV and VOIP strategies are
important. Today this is mostly the case in Asia.

EPON is part of standard Ethernet, which is very simple to manage


The collapsed layering model of EPON results in less complex management than GPON
OSS integration is much easier with EPON due to the wide support of IP/Ethernet in most NextGen
OSS systems.

EPON is receiving considerable endorsements in Asia today, while in the US leading RBOCs are embarking
on large-scale, ATM-limited BPON deployments
The lack of any significant GPON RFP clearly illustrates its relevance today
Most key BPON vendors are working on GPON follow-on products, often sold as a future-proof strategy
Most key Asian vendors are focused on EPON
GPONs flagship Class-C ODN and 2.4Gbps transceivers are in reality very expensive and do not have the
advantage of volumes that can help drive down costs. Partition Noise currently limits the GPON upstream
speed to 622 Mbps, until narrow spectral width FP lasers become economical

Business applications that include TLS, Bridging

Management and OSS integration of EPON is much easier than GPON, due to the following

Large-scale IPTV deployment, which is often seen as a key driver for Gbps PON deployments

I.e., in reality, GPON and EPON solutions offer about the same bandwidth today with GPON
slightly better in the downstream direction, and EPON slightly better upstream

GPON, in reality, represents an evolutionary step from BPON to EPON

References
[1]
[2]
[3]
[4]

GPON spec ITU G.984.3


EPON spec IEEE 8023ah
How efficient is PON? By Glen Kramer/Teknovus
GPON efficiency paper by Alcatel

Page 16 of 17

EPON vs. GPON

4 Appendix
Recommendations for BPON and GPON
Rec.

Title

GPON comments

EPON comments

BPON
G.983.1

Broadband optical access systems based on Passive Optical Networks (PON)

Based on this
framework

Based on this framework

G.983.2

ONT management and control interface specification for B-PON

Included

Equivalent MIBs via IETF

G.983.3

A broadband optical access system with increased service capability by


wavelength allocation

Based on this
framework

Based on this framework

G.983.4

A broadband optical access system with increased service capability using


dynamic bandwidth assignment (DBA)

Based on this
framework

Out of IEEE scope

G.983.5

A broadband optical access system with enhanced survivability

Included

Out of IEEE scope

G.983.6

ONT management and control interface specifications for B-PON system with
protection features

Included

Out of IEEE scope

G.983.7

ONT management and control interface specification for dynamic bandwidth


assignment (DBA) B-PON system

Based on this
framework

Out of IEEE scope, controls


supported

G.983.8

B-PON OMCI support for IP, ISDN, video, VLAN tagging, VC cross-connections
and other select functions

Included

Equivalent MIBs via IETF

G.983.9

B-PON ONT management and control interface (OMCI) support for wireless Local
Area Network interfaces

Included

Equivalent MIBs via IETF

G.983.10

B-PON ONT management and control interface (OMCI) support for Digital
Subscriber Line interfaces

Included

Equivalent MIBs via IETF

GPON
G.984.1

Gigabit-capable Passive Optical Networks (GPON): General characteristics

(=GPON)

See table 1

G.984.2

Gigabit-capable Passive Optical Networks (GPON): Physical Media Dependent


(PMD) layer specification

(=GPON)

Class A and B, relaxed


parameters

G.984.3

Gigabit-capable Passive Optical Networks (G-PON): Transmission convergence


layer specification

(=GPON)

Pure-Ethernet based

G.984.4

Gigabit-capable Passive Optical Networks (G-PON): ONT management and


control interface specification

(=GPON)

Equivalent MIBs via IETF

The gray areas indicate where GPON and EPON are more or less equivalent.

Page 17 of 17