Professional Documents
Culture Documents
Compressor
type
Capacity FAD*
Noise
level**
Atlas Copco
Weight (kg/lbs)***
bar(e)
psi
l/s
m3/h
cfm
kW
hp
dB(A)
Pack
Full Feature
10
10
10
10
7.5
10
13
7.5
10
13
145
145
145
145
109
145
189
109
145
189
4.0
5.3
7.8
10.0
19.6
16.1
12.9
27.0
23.3
19.0
14.4
19.1
28.1
36.0
70.6
58.0
46.4
97.2
83.9
68.4
8.5
11.2
16.5
21.2
41.5
34.1
27.3
57.2
49.4
40.3
2.2
3
4
5.5
7.5
7.5
7.5
11
11
11
3
4
5
7.5
10
10
10
15
15
15
61
61
62
64
65
65
65
68
68
68
165/364
165/364
165/364
165/364
245/540
245/540
245/540
257/567
257/567
257/567
200/441
200/441
200/441
200/441
314/692
314/692
314/692
326/719
326/719
326/719
10.3
10.3
10.3
7.4
9.1
10.8
12.5
7.4
9.1
10.8
12.5
150
150
150
107
132
157
181
107
132
157
181
4.0
7.8
10.0
19.5
17.3
14.9
12.3
27.8
24.7
22.5
20.0
14.4
28.1
36.0
70.2
62.3
53.6
44.3
100.1
88.9
81.0
72.0
8.5
16.5
21.2
41.3
36.7
31.6
26.1
58.9
52.3
47.7
42.4
2.2
4
5.5
7.5
7.5
7.5
7.5
11
11
11
11
3
5
7.5
10
10
10
10
15
15
15
15
61
62
64
67
67
67
67
68
68
68
68
165/364
165/364
165/364
245/540
245/540
245/540
245/540
257/567
257/567
257/567
257/567
200/441
200/441
200/441
314/692
314/692
314/692
314/692
326/719
326/719
326/719
326/719
50 Hz version
GX 11
60 Hz VERSION
GX 2
GX 4
GX 5
GX 7
GX 11
Available options
GX 2-5
GX 2-5 FF
GX 7-11
GX 7-11 FF
Integrated aftercooler
Water separator (shipped loose)
Timer water drain on water separator (shipped loose)
Timer drain on air receiver (tank mounted only)
N/A
N/A
N/A
N/A
Installed
N/A
Installed
Installed
N/A
N/A
Installed
Installed
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
W (mm/in.)
H (mm/in.)
620/24.5
810/31.9
605/23.8
590/23.2
975/38.4
1085/42.7
N/A
1205/47.5
N/A
590/213.2
N/A
1085/42.7
575/22.6
590/23.2
1280/50.4
1332/52.4
1420/55.9
1533/60.4
1420/55.9
1935/76.2
575/22.6
590/23.2
1280/50.4
1463/57.6
Length of GX7-11 tank mounted 500 l/120 gal unit is 1875 mm.
2-11 kW/3-15 hp
Member:
The information contained herein is general in nature and is not intended for specific construction,
installation or application purposes
GX 2-11
Danger: Compressed air should never be supplied as breathing air unless air is properly purified for
breathing. Atlas Copco assumes no responsibility or liability related to the purchasers/users
breathing air system.
L (mm/in.)
GX 2
GX 3
GX 4
GX 5
GX 7
New GX series:
screw compressors built to last
Atlas Copco screw compressors have always set the standard for
reliability and performance in the compressed air industry. With the new
GX 2-11, Atlas Copco brings the power and reliability of an industrial
screw compressor to small and medium sized industries.
Moisture, dirt particles and aerosols in plant air can damage your
piping, compressed air tools and machinery as well your end products.
To keep production operations running smoothly, you are in need
of clean and dry compressed air. An integrated dryer and an in-line air
filter equipped in the GX 2-11 FF variants can do the job perfectly.
Element
Controller
Unloader
Integrated dryer
3
1
4
BUILT-IN RELIABILITY
Rugged screw compressor technology allows for a 100% continuous
duty cycle.
Sophisticated design based on Atlas Copcos experience and long history
of success.
Extended working limitation up to 115F ambient temperature
through the selection of robust components.
Reinforced frame which eliminates all resonance and ensures stable
running and long life time.
Vacuum and air pressure operated inlet valve offering superior reliability
compared to a traditional spring driven design.
All oil lines are rigid pipe or high temperature hose.
No plastic oil tubing is used.
All electrical wiring is done with heavy-duty cable and high quality connectors.
The GX package includes the main switch with integrated circuit breaker
to protect the compressor.
SILENT POWER
The GX 2-11 compressors are supplied with full sound enclosures,
which reduce the sound levels as low as 61 dB(A).
Flow chart
AIR FLOW
1. Inlet air filter
2. Inlet valve
3. Compression element
4. Oil separator element
5. Minimum pressure valve
6. Aftercooler
7. Air receiver
OIL FLOW
8. Oil reservoir
9. Oil cooler
10. Thermostatic valve block
11. Oil filter
REFRIGERANT FLOW
12. Evaporator
13. Refrigerant compressor
14. Condenser
15. Capillary tube
16. Water separator
17. Electronic automatic drain
12
Intake air
Air/oil mixture
16
13
Oil
17
C
1
15
14
Options
A - Full Feature
B - PDx high efficiency air filter
C - Electronic receiver drain
Wet air
11
Dry air
Water
10
6
3
8
9
Refrigerant gas
Refrigerant liquid
Capacity FAD*
Noise
level**
Atlas Copco
Weight (kg/lbs)***
bar(e)
psi
l/s
m3/h
cfm
kW
hp
dB(A)
Pack
Full Feature
10
10
10
10
7.5
10
13
7.5
10
13
145
145
145
145
109
145
189
109
145
189
4.0
5.3
7.8
10.0
19.6
16.1
12.9
27.0
23.3
19.0
14.4
19.1
28.1
36.0
70.6
58.0
46.4
97.2
83.9
68.4
8.5
11.2
16.5
21.2
41.5
34.1
27.3
57.2
49.4
40.3
2.2
3
4
5.5
7.5
7.5
7.5
11
11
11
3
4
5
7.5
10
10
10
15
15
15
61
61
62
64
65
65
65
68
68
68
165/364
165/364
165/364
165/364
245/540
245/540
245/540
257/567
257/567
257/567
200/441
200/441
200/441
200/441
314/692
314/692
314/692
326/719
326/719
326/719
10.3
10.3
10.3
7.4
9.1
10.8
12.5
7.4
9.1
10.8
12.5
150
150
150
107
132
157
181
107
132
157
181
4.0
7.8
10.0
19.5
17.3
14.9
12.3
27.8
24.7
22.5
20.0
14.4
28.1
36.0
70.2
62.3
53.6
44.3
100.1
88.9
81.0
72.0
8.5
16.5
21.2
41.3
36.7
31.6
26.1
58.9
52.3
47.7
42.4
2.2
4
5.5
7.5
7.5
7.5
7.5
11
11
11
11
3
5
7.5
10
10
10
10
15
15
15
15
61
62
64
67
67
67
67
68
68
68
68
165/364
165/364
165/364
245/540
245/540
245/540
245/540
257/567
257/567
257/567
257/567
200/441
200/441
200/441
314/692
314/692
314/692
314/692
326/719
326/719
326/719
326/719
50 Hz version
GX 11
60 Hz VERSION
GX 2
GX 4
GX 5
GX 7
GX 11
Available options
GX 2-5
GX 2-5 FF
GX 7-11
GX 7-11 FF
Integrated aftercooler
Water separator (shipped loose)
Timer water drain on water separator (shipped loose)
Timer drain on air receiver (tank mounted only)
N/A
N/A
N/A
N/A
Installed
N/A
Installed
Installed
N/A
N/A
Installed
Installed
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
W (mm/in.)
H (mm/in.)
620/24.5
810/31.9
605/23.8
590/23.2
975/38.4
1085/42.7
N/A
1205/47.5
N/A
590/213.2
N/A
1085/42.7
575/22.6
590/23.2
1280/50.4
1332/52.4
1420/55.9
1533/60.4
1420/55.9
1935/76.2
575/22.6
590/23.2
1280/50.4
1463/57.6
Length of GX7-11 tank mounted 500 l/120 gal unit is 1875 mm.
2-11 kW/3-15 hp
Member:
The information contained herein is general in nature and is not intended for specific construction,
installation or application purposes
GX 2-11
Danger: Compressed air should never be supplied as breathing air unless air is properly purified for
breathing. Atlas Copco assumes no responsibility or liability related to the purchasers/users
breathing air system.
L (mm/in.)
GX 2
GX 3
GX 4
GX 5
GX 7
New GX series:
screw compressors built to last
Atlas Copco screw compressors have always set the standard for
reliability and performance in the compressed air industry. With the new
GX 2-11, Atlas Copco brings the power and reliability of an industrial
screw compressor to small and medium sized industries.
Moisture, dirt particles and aerosols in plant air can damage your
piping, compressed air tools and machinery as well your end products.
To keep production operations running smoothly, you are in need
of clean and dry compressed air. An integrated dryer and an in-line air
filter equipped in the GX 2-11 FF variants can do the job perfectly.
Element
Controller
Unloader
Integrated dryer
3
1
4
BUILT-IN RELIABILITY
Rugged screw compressor technology allows for a 100% continuous
duty cycle.
Sophisticated design based on Atlas Copcos experience and long history
of success.
Extended working limitation up to 115F ambient temperature
through the selection of robust components.
Reinforced frame which eliminates all resonance and ensures stable
running and long life time.
Vacuum and air pressure operated inlet valve offering superior reliability
compared to a traditional spring driven design.
All oil lines are rigid pipe or high temperature hose.
No plastic oil tubing is used.
All electrical wiring is done with heavy-duty cable and high quality connectors.
The GX package includes the main switch with integrated circuit breaker
to protect the compressor.
SILENT POWER
The GX 2-11 compressors are supplied with full sound enclosures,
which reduce the sound levels as low as 61 dB(A).
Flow chart
AIR FLOW
1. Inlet air filter
2. Inlet valve
3. Compression element
4. Oil separator element
5. Minimum pressure valve
6. Aftercooler
7. Air receiver
OIL FLOW
8. Oil reservoir
9. Oil cooler
10. Thermostatic valve block
11. Oil filter
REFRIGERANT FLOW
12. Evaporator
13. Refrigerant compressor
14. Condenser
15. Capillary tube
16. Water separator
17. Electronic automatic drain
12
Intake air
Air/oil mixture
16
13
Oil
17
C
1
15
14
Options
A - Full Feature
B - PDx high efficiency air filter
C - Electronic receiver drain
Wet air
11
Dry air
Water
10
6
3
8
9
Refrigerant gas
Refrigerant liquid
New GX series:
screw compressors built to last
Atlas Copco screw compressors have always set the standard for
reliability and performance in the compressed air industry. With the new
GX 2-11, Atlas Copco brings the power and reliability of an industrial
screw compressor to small and medium sized industries.
Moisture, dirt particles and aerosols in plant air can damage your
piping, compressed air tools and machinery as well your end products.
To keep production operations running smoothly, you are in need
of clean and dry compressed air. An integrated dryer and an in-line air
filter equipped in the GX 2-11 FF variants can do the job perfectly.
Element
Controller
Unloader
Integrated dryer
3
1
4
BUILT-IN RELIABILITY
Rugged screw compressor technology allows for a 100% continuous
duty cycle.
Sophisticated design based on Atlas Copcos experience and long history
of success.
Extended working limitation up to 115F ambient temperature
through the selection of robust components.
Reinforced frame which eliminates all resonance and ensures stable
running and long life time.
Vacuum and air pressure operated inlet valve offering superior reliability
compared to a traditional spring driven design.
All oil lines are rigid pipe or high temperature hose.
No plastic oil tubing is used.
All electrical wiring is done with heavy-duty cable and high quality connectors.
The GX package includes the main switch with integrated circuit breaker
to protect the compressor.
SILENT POWER
The GX 2-11 compressors are supplied with full sound enclosures,
which reduce the sound levels as low as 61 dB(A).
Flow chart
AIR FLOW
1. Inlet air filter
2. Inlet valve
3. Compression element
4. Oil separator element
5. Minimum pressure valve
6. Aftercooler
7. Air receiver
OIL FLOW
8. Oil reservoir
9. Oil cooler
10. Thermostatic valve block
11. Oil filter
REFRIGERANT FLOW
12. Evaporator
13. Refrigerant compressor
14. Condenser
15. Capillary tube
16. Water separator
17. Electronic automatic drain
12
Intake air
Air/oil mixture
16
13
Oil
17
C
1
15
14
Options
A - Full Feature
B - PDx high efficiency air filter
C - Electronic receiver drain
Wet air
11
Dry air
Water
10
6
3
8
9
Refrigerant gas
Refrigerant liquid
Capacity FAD*
Noise
level**
Atlas Copco
Weight (kg/lbs)***
bar(e)
psi
l/s
m3/h
cfm
kW
hp
dB(A)
Pack
Full Feature
10
10
10
10
7.5
10
13
7.5
10
13
145
145
145
145
109
145
189
109
145
189
4.0
5.3
7.8
10.0
19.6
16.1
12.9
27.0
23.3
19.0
14.4
19.1
28.1
36.0
70.6
58.0
46.4
97.2
83.9
68.4
8.5
11.2
16.5
21.2
41.5
34.1
27.3
57.2
49.4
40.3
2.2
3
4
5.5
7.5
7.5
7.5
11
11
11
3
4
5
7.5
10
10
10
15
15
15
61
61
62
64
65
65
65
68
68
68
165/364
165/364
165/364
165/364
245/540
245/540
245/540
257/567
257/567
257/567
200/441
200/441
200/441
200/441
314/692
314/692
314/692
326/719
326/719
326/719
10.3
10.3
10.3
7.4
9.1
10.8
12.5
7.4
9.1
10.8
12.5
150
150
150
107
132
157
181
107
132
157
181
4.0
7.8
10.0
19.5
17.3
14.9
12.3
27.8
24.7
22.5
20.0
14.4
28.1
36.0
70.2
62.3
53.6
44.3
100.1
88.9
81.0
72.0
8.5
16.5
21.2
41.3
36.7
31.6
26.1
58.9
52.3
47.7
42.4
2.2
4
5.5
7.5
7.5
7.5
7.5
11
11
11
11
3
5
7.5
10
10
10
10
15
15
15
15
61
62
64
67
67
67
67
68
68
68
68
165/364
165/364
165/364
245/540
245/540
245/540
245/540
257/567
257/567
257/567
257/567
200/441
200/441
200/441
314/692
314/692
314/692
314/692
326/719
326/719
326/719
326/719
50 Hz version
GX 11
60 Hz VERSION
GX 2
GX 4
GX 5
GX 7
GX 11
Available options
GX 2-5
GX 2-5 FF
GX 7-11
GX 7-11 FF
Integrated aftercooler
Water separator (shipped loose)
Timer water drain on water separator (shipped loose)
Timer drain on air receiver (tank mounted only)
N/A
N/A
N/A
N/A
Installed
N/A
Installed
Installed
N/A
N/A
Installed
Installed
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
W (mm/in.)
H (mm/in.)
620/24.5
810/31.9
605/23.8
590/23.2
975/38.4
1085/42.7
N/A
1205/47.5
N/A
590/213.2
N/A
1085/42.7
575/22.6
590/23.2
1280/50.4
1332/52.4
1420/55.9
1533/60.4
1420/55.9
1935/76.2
575/22.6
590/23.2
1280/50.4
1463/57.6
Length of GX7-11 tank mounted 500 l/120 gal unit is 1875 mm.
2-11 kW/3-15 hp
Member:
The information contained herein is general in nature and is not intended for specific construction,
installation or application purposes
GX 2-11
Danger: Compressed air should never be supplied as breathing air unless air is properly purified for
breathing. Atlas Copco assumes no responsibility or liability related to the purchasers/users
breathing air system.
L (mm/in.)
GX 2
GX 3
GX 4
GX 5
GX 7