You are on page 1of 2

MV/LV Prefabricated Substations

Integrated substation

Design
Compliance with
standards

IEC

BS

Discovering our offer at a glance

Compact substation

Walk-in substations

Products and equipment


for Medium Voltage distribution networks up to 5 MVA

Specific

Switching
kiosk

MV/LV

MV/LV

MV/LV
Tailor made
Underground

IEC/HN

IEC/AS

IEC/HN

IEC

Medium Voltage equipment Panorama


Air insulated switchgear

Unisarc

Electrical equipment
Max Rated voltage

IEC

SM6
SM6-24

SM6-36

IEC

IEC

Distribution transformer

Gas insulated switchgear

Fluokit

HVL

HVL/cc

Ringmaster FBX

RM6

CAS36

DV-CAS

Flusarc

IEC

ANSI

ANSI

IEC

IEC

IEC

IEC

IEC / ANSI

IEC / ANSI

1200 A

1200 A

630 A

630 A

630 A

630 A

630 A

630 A

25 kA

20 kA

20 kA

25 kA

SF6 CB
SF6 LBS

SF6 LBS

Vacuum CB

Vacuum CB

Trihal

Minera

Minera HE

Minera PV

Minera ATEX

Vegeta

Siltrim

5 MVA

5 MVA

5 MVA

1.5 MVA

5 MVA

5 MVA

3,3 MVA

Solid
insulation

Insulating Insulating
liquid
liquid

Insulating liquid

Insulating liquid Biodegradable


insulating liquid

Mineral oil Mineral oil

Mineral oil

Mineral oil

Vegetal oil

Synthetic or
natural ester

High Efficiency
Ground
Oil-Immersed
Mounted
Transformer
OilImmersed
Distribution
Transformer

Oil-Immersed
Transformer for
Photovoltaic
Applications

Transformers for
Hazardous Areas

Ecological
Oil-Immersed
Transformer

Compact and
Fire Resistant
Oil-Immersed
Transformer

RATED VOLTAGE
3150 kVA
2000 kVA

Transformer Max
power

1250 kVA
630 KVA

250 kVA

Material of the
enclosure
Metal n
GRC (Glass
ReinforcedCement) n
Concrete n

1 x 1000 kVA
or 2 x 630 Kva

MAX. RATED CURRENT

Design
Use

Application

Indoor

The MV and LV equipment are


delivered directly mounted
ensuring a safety, and fast
solution.They can be installed
in existing building, in a
substation or outdoor.

Outdoor operations type of


substation allows reduce
footprint and speed of
installation. Internal equipment
arrangement can be fitted to
any type of access.

Indoor

Indoor

Indoor operations type of


substation provides to operators
a protection against bad weather
and better working conditions.

630 A

Indoor

These substations
offer modularity of
their dimensions
to respond to
all equipment
requirements.

Reconfiguring the MV network and protecting the MV/LV transformer with our MV switchgear
ranges. Supplying LV energy with Minera and Trihal ranges.
Distributing and protecting the LV network with Opus and Prisma Plus ranges.
Managing functions remotely with Easergy Flair 200C, Easergy T200 and Easergy W200.
Distribution
Industry
Buidings

Distribution
Industry
Buidings

IEC 62271-202
standard

Schneider Electric Industries SAS


89, boulevard Franklin Roosevelt
F-92505 Rueil-Malmaison cedex
Tel : +33 (0) 1 41 29 85 00
www.schneider-electric.com
NRJED111045EN

Outdoor

Indoor/outdoor Outdoor

ART. 838525 - schneider Electric - All rights reserved

Operation

Distribution

Primary distribution,
Large industries, Oil
& Gas, Mine & Metal,
Solar & Wind

Use of equipment conform to IEC standards


Degree of protection
Electromagnetic compatibility
Functional tests
Temperature class
Non-flammable materials
Mechanical resistance of the enclosure
Sound level
Insulation level
Internal arcing withstand
Earthing circuit test
Oil retention

As standards, specifications and designs change from time to time, please ask for
confirmation of the information given in this publication.
This document has been printed
on ecological paper

Publishing: Schneider Electric Industries SAS


Design: Schneider Electric Industries SAS
Printing Altavia

06-2011

630 A & 1250A

630 A

1250 A

630 A

630/
1250A

630 A

option busbar
1250A

MAX. RATED SHORT CIRCUIT CURRENT


20 kA

25 kA

20 kA

Vacuum
CB

SF6/vacuum CB

SF6 CB

25 kA

25 kA

20 kA

20 to
61 kA

32 kA 40 kA 21 kA

Open-air SF6 switch


Switch

SF6 CB
SF6 LBS

25 kA

21 kA

Vacuum CB
SF6 LBS

Complete
system of
modular
cubicles

Complete system of Complete system of Complete system of


modular cubicles
modular cubicles
modular cubicles

Compact and
modular
switchgear
combining all MV
functional units

Compact and modular


switchgear combining
all MV functionnal
units

Compact
and modular
switchgear
combining all MV
functional units

Compact
switchgear
combining all MV
functional units
used in RMU

Compact and modular


Wind dedicated
modular switch- switchgear combining
all MV functionnal units
gear combining
all MV functional
units used in wind
farms

Indoor

Indoor

Indoor

Indoor

Indoor and
outdoor

Indoor

Indoor

Indoor

Indoor

Indoor

IAC

IAC

IAC

IAC

IAC

IAC

IAC

IAC

IAC

IAC

IAC

IAC

SelfExtinguishing
Cast
Resin Dry
Transformer

Hire fire point


insulating liquid
Compact design

Medium Voltage products Panorama


SCADA

Substation
Control unit

Remote
monitoring

Fault passage indicator

Easergy
Flite 116-SA/G200

Easergy
Flite

LBSkit

ISR

ISARC

L-TRI 5

TRI

Detection

Detection

IEC

IEC

IEC

IEC/EN

IEC/EN

Easergy
T200I - T200E

Easergy
Flair 200C

Easergy
Flair

DAX

Easergy
Flair 2xd

Easergy
T200P

Remote control system

Switch
monitoring and
control unit

Detection

Detection

Detection

Detection

Phase and earth fault

phase and earth fault

phase and earth fault

phase and earth fault

Setting

Setting

Setting

on site by dip switch

on site by HMI through


push buttons

on site by dip switch


or with keyboard

Switch or sectionaliser Control


monitoring and control Controls recloser
unit
Protection
Fault indicator: phase

Installation
Wall-mounted
Fault indicator:
Network and substation views phase and earth fault
500 Easergy type devices

Alarm logs, archives

Data configuration
Professional communications
and database editor
Data creation via dialogue
boxes

Capacity
1-16 switches

Battery
autonomy

Earthing
system: direct,
impedent,
compensated, isolated

wall mounted
3 phases or / and
earth CT

Measurement

Motorisation

U,I, P, Q, S, cos
6 D.I., 3 D.O.

Earthing system
direct,
impedant,
compensated, isolated

Protocols

Protocols

Protocols

Modbus, Modbus IP,


IEC 101/104

Modbus/IP,
IEC 870-5-101/104,
DNP3, DNP3/IP

IEC 870-5-101, DNP3,


Modbus

Communication

Communication

Communication

Permanent and non permanent: telephone/GSM, radio,


direct public and dedicated
private line
Periodic call management

Radio, PSTN, GSM,


GPRS

1 Communcation port ,
Transmission interfaces:
PSTN, Radio,GSM,GPRS,
Ethernet, RS232, RS485...

Webview, Multistation and


Horn/Lamp indication options

Installation

wall mounted
3 phases or / and
earth CT

16 h

24 - 48 Vdc

Option

Installation

Installation

and earth fault

Measurement

ADVC

Capacity

Measurement

2 switches

16h

Current, voltage, real power,


power factor, demand,
harmonics, supply outages,
waveform capture

Motorisation voltage

Setting

Battery autonomy

Measurement

24-48 Vdc

ammeter,
maximeter

Protocols

Mounted on the pole or


substation frame

Modbus, Modbus/IP,
IEC 870-5-101/104, DNP3,
DNP3/IP

Protocols

Communication

Communication

Radio, PSTN, GSM, GPRS

Radio, modem, GSM, V23,


RS232, RS485, 10BaseT Ethernet

DNP3, IEC 870-5-101/104


Modbus/IP and DNP3/IP

Modbus IEDs
concentrator

digital

digital

digital

digital

digital

digital

digital

Associated with all types


of MV switchgear

MV substation remote
monitoring unit

Phase and earth fault


indicator for
underground network

Phase and earth fault


indicator for
underground network

Phase and earth fault


indicator for
underground network

Associated with a pole


mounted switch

T200E associated with


Ringmaster only;
limited to 4 switches.

Battery
220 Vac backed-up supply

Advanced controller associated


with N, U and W Series
reclosers, and RL Series
sectionaliser

Lithium
battery power

Lithium battery power


and/or
LV power

Self powered by CTs

Embedded web server


Local and remote
configuration

Ensures remote control


and automated
management

Remote setting with WSOS monitoring and control software


Electronics sealed to IP65, 316
grade stainless steel enclosure

VEIVacuum L

Fluvac

Instrument
transformer

Fuse

SF1, SFset

Fusarc CF

Solefuse Tepefuse, Fusarc CF MGK

IEC/ANSI

DIN/IEC

IEC/UTE

IEC/DIN/UTE

CT, VT

LPCT

Power factor
correction

CT, VT

Propivar

Pole mounted switchgear

CP 200 series PM6

IEC

AFNOR

PM6 52

Flusarc-PLA

RL series N series

U series

W series

SBC

TRLF

IEC

IEC

ANSI

ANSI

ANSI

IEC

IEC

ANSI

phase and earth fault

on site by dip switch

38

Installation

38

clip on or pole
mounted

Earthing system
Protocols

By laptop, operator control panel, IEC 870-5-101, Serial


DNP3 and TCP/IP,
Scada
Modbus

Installation

Circuit breaker

Setting

Phase and earth current,


directional, voltage, frequency,
harmonics

Modbus IEDs
concentrator

Ensure remote control


and automated
management
Embedded web server
Local and remote
configuration

Phase-to-phase and
phase-to-earth fault

Current, voltage, real power,


Installation
DIN format
reactive power, power
Detection
integrated into switch- factor, demand, cos
Phase and earth faults, directional clip on or G200 pole
mounted
gear

direct,
impedant

AIR Switch /
disconnector AIR disconnector

Fault passage indicator

Easergy L500

Capacity

Switch /
disconnector

Overhead network control units

direct,
impedant,
compensated,
isolated

630/1250 A

630 A

400 A
630 A

630 A
1600 A
2500 A

25 kA

25 kA

25 kA

20 kA

digital

SF6

SF6

Air

Earth and
phase-to-phase fault
indicators
for overhead
distribution lines

Indoor load break


switch,
disconnector and
accessories

Indoor load
break switch
disconnector
and accessories

Indoor load
break switch
disconnector
and
accessories

1600 A max

630 A

1250 A

20 kA

25 kA

25 kA

25 kA

Air

Air

Vacuum

Vacuum
CB/SF6

SF6

Indoor load
break switch
disconnector
and
accessories

Indoor
disconnector
and
accessories

Fixed, removable,
or withdrawable
circuit breaker
Side mounted
mechanism

Fixed circuit
breaker,
integrating:
Vacuum circuit
breaker,
Disconnector
earthing
switch,
Reduced width
insulated in
SF6
(SF6 can be
replaced by
Nitrogen for
12 kV) and
accessories

Fixed circuit
breaker

250A

125 A

2.5 A

250 A

5000 A

2500 A

2500 A

50 kA

40 kA

50 kA

dry

dry

dry

Ring type
and medium
voltage
Current
Transformer,
Voltage
Transformer

Ring type
and medium
voltage
Low Power
Current
Transformer
(LPCT)

Outdoor
Current
Transformer
and Voltage
Transformer

600 kvar

14400 kvar

630 A

630 A

630 A

630 A

800 A

630 A

400 A

630 A

1250 A

31.5 kA

16 kA

12.5 kA/3 s 25 kA

16 kA

16 kA

12.5 kA

6 kA

20 kA

16 kA

"all film"
with or
without
internal
fuses

vacuum / SF6

SF6

SF6

SF6

vacuum/
SF6

vacuum/
epoxy

vacuum/
epoxy

Air

Air

Power factor
correction on
MV networks
or devices

Power factor
correction and
harmonic filtering
on MV networks

Load break switch

Load break switch

Load break
switch

Recloser

Recloser

Single Wire
Earth Return
(SWER)
Recloser

Air break
switch

Air disconnector or
switch-disconnector

Manualy
operated

Manualy operated

Communication
915 MHz short range
radio communication
1 SCADA communication
port
Transmission interface:
radio, GSM, GPRS

Communicating fault current detector for overhead


lines
Single-phase
ammetric detector

Lithium
battery power

Front or side
mounted
mechanism
VIP integrated
trip unit (without
auxiliary power
supply) in SFset
up to 24 kV

l1

l1

l1

l1

63 kA

50 kA

63 kA

50 kA

Fuses for
distribution
transformer
from 3.6 kV to
36 kV

Fuse for measurement


Motor
transformer protection up to protection
24 kV (Tepefuse) and up to fuse range
36 kV (Fusarc CF)
Back-up technology

Fixed or automatic Remote controlled with


capacitor banks for Easergy T200 P control
motor, substation, unit
or global
distribution
Indoor or outdoor
installation

Remote controlled with ADVC controller

Manualy operated

Manual or automatic
load break switch

Manual or
automatic
load break
switch

Sectionaliser capabilities

Sectionaliser
capabilities
on voltage
and current

Advanced protection, control and


communication

You might also like