You are on page 1of 12

ACY Y

IT
CUR BIL
AC GEA
5% AN
.0 07 :1 R
0
12

SERIES
SMART PRESSURE TRANSMITTERS
4 to 20 mA + HART® Digital Communication

smar
FEATURES

9 0.075% accuracy 9 16 MPa and 32 MPa static pressure (2320 psi and 4600 psi)
9 120:1 rangeability NEW 9 Small and lightweight
9 0-125 Pa to 0-40 MPa (0-0.5 inH2O to 0-5800 psi) 9 Explosion proof and weather proof housing
9 Direct digital capacitance sensing (No A/D conversion) 9 Intrinsically safe
9 4-20 mA output plus direct digital communication 9 Constant signal generation for loop tests
(HART® Protocol), according to NAMUR-NE-43 standard
9 Fully interchangeable parts for easy maintenance
9 Updating time of output current in 100ms
9 Optional PID control function with antireset wind-up,
9 Output current resolution of 0.75µA/bit output limitation, rate-of-change limitation, bumpless
auto/manual transfer, etc.
9 With high performance mathematical co-processor
9 16 points table for PID output and input, configurable by the user
9 One single eletronic board for all models
9 EU indication, file configuration, diagnóstics, calibration file,
9 True noninteractive zero and span identification, etc, via Hand Held or PC through CONF301,
CONF401
9 Local zero and span adjustment
9 Fail-safe level
9 Remote calibration
9 Flow totalization with persistence
9 Password protection
9 User unit
9 On-line and off-line programming
9 EMI effects: Conforms to IEC 61000-6-2, IEC 61000-6-4, IEC 61326
9 Multi-drop operation mode
9 FMEDA (Failure Modes Effects and Diagnostic) Analysis
9 Output functions: linear, √x, √x3, √x5, special function and
constant current 9 MTBF (Mean Time Between Failures) of 244 years
9 Optional 4½-digit numerical and 5-character 9 MTTR (Mean Time to Repair) of 18 minutes
alphanumerical LCD indicator
9 MTTF (Mean Time to Failure) of 244 years
9 ISO 9001 certified
9 Applicable in safety areas according to SIL (Safety Integrity
9 Indication in engineering units, configuration file, Level) requirements
diagnosis, etc., available in the Hand-Held Terminal
9 Write protection by hardware
9 16-point freely programmable output characterization
9 Easy update for Foundation Fieldbus and Profibus PA
9 Capable of handling most process fluids Technologies

smar 2
DESCRIPTION

SENSING DIAPHRAGM (1)


ISOLATING DIAPHRAGM (2)
FILLING FLUID (3)
CERAMICS
METALIZED SURFACE (4)
GLASS
STEEL

The LD301 series uses, as its measuring principle, the well- The Electronic Circuit measures the variation of the capacitance
known and field proven technique of capacitance sensing, between the moving and fixed plates, and generates a 4-20 mA
enhanced by a microprocessor based electronics. signal, that can be proportional to the differential pressure applied
or characterized (square root, special function, etc.) to it. Being
Designed for process control applications, these 2-wire microprocessor based, the electronic circuit is extremely
transmitters generate a 4-20 mA signal proportional or versatile and accurate. Besides a "super chip", the HT3012, a
characterized to the applied differential pressure. This signal 4-in-1 processor offloads the regular microprocessor adding
can be transmitted over a pair of twisted wires through tremendous "house power" to the LD301. This chip provides
long distances (limited only by the wire resistance and the floating-point coprocessor, the HART communication
load). Digital communication for remote calibration and controller, the LCD controller and the D/A converter, that
monitoring is also provided, superimposing a digital signal combined with the sensor precision, provides the high accuracy
on the same pair of wires that carries the 4-20 mA signal. and rangeability peculiar of the LD301 series.
The HT3012 chips is a high integration chip that allows that
Remarkable features of the LD301 series are its 0.075% high all LD301 series can be characterizated by one single
accuracy, 120:1 rangeability, compactness and light- eletronic board, simplifying maintenance and with a high
weightiness, PID control capability (optional), etc. MTBF at the market.
Transmitter performance is improved by continuous monitoring
The transmitter consists of two main parts. The sensor (a of the sensor temperature and corresponding corrections.
capacitance variation cell) and the electronic circuit.
The transmitter can also operate as a combination of transmitter
The sensor is schematically shown in the above drawing. A plus controller. In this case, the 4-20 mA signal is used as the
sensing diaphragm (1) is shown at the center of the cell. This output of a PID control function (optional), while the digital
diaphragm deflects, as a result of the difference between the signal may be used for remote monitoring and operation.
pressures applied to the left and right sides of the sensor.
Besides the LD301 series was developed according to the
These pressures are directly applied to the isolating
international safety standards to attend the functional safety
diaphragms (2), that provide isolation and resistance against
requirements in plants that need safety and reliability to protect
process fluid corrosion. The pressure is transmitted to the
people, ambient and assets, etc.
sensing diaphragm through the filling Fluid (3).
The LD301 series has FMEDA analyzes allowing all serie to
work in safety areas according to SIL requirements and making
The sensing diaphragm is also a moving capacitor plate, and
easier to the user the calculation for Safety Integrity Level (SIL).
the two metallized surfaces (4) are fixed plates. The sensing
diaphragm deflection results in a variation on the
capacitances between the moving and fixed plates. MTBF is a basic measure of product and it is calculated adding
the MTTR and MTTF. MTTR is the mean time to execute
maintenance on all of the removable items in a product. It is the
most common measure of maintainability.
MTTF is the mean time expected until the first failure of a piece
of equipament. It is the inverse of the failure rate.

3 smar
BLOCK DIAGRAM

CONSTRUCTION

Wetted parts of the sensor are available in the following


materials:
9 316L Stainless Steel
9 Hastelloy CTM
9 Monel 400TM
9 Tantalum
The isolating diaphragms are made of 316L stainless
steel in the standard versions. They can optionally be
provided in Hastelloy, Monel or Tantalum.
Process flanges and adapters are available in plated carbon
steel, 316 stainless steel, Hastelloy C or Monel.
This ensures compatibility of the transmitter with most
industrial fluids.
Electronic housing is available in the following materials:
9 Aluminum
9 316 Stainless Steel
The electronic housing is a sturdy Explosion Proof and Weather
Proof construction.
The electronic circuit boards are tropicallized and are
intrinsically safe for use in hazardous areas.

smar 4
VERSIONS

The different versions are obtained as follows:

DIFFERENTIAL PRESSURE (DP)


Applying pressure to both sides of the sensor.
This is also used in many level applications. For high static
pressure applications the “H” model is available.

FLOW MEASUREMENT
The 4-20 mA signal can be made proportional to the square
root of the differential pressure applied. It is normally used
together with a primary flow element such as orifice plate,
integral orifice, Venturi tubes, etc.

GAGE PRESSURE
Pressure is applied to one side of the sensor while the other
side is open to atmosphere.

ABSOLUTE PRESSURE
A chamber is welded on one side of the sensor and then
vacuum sealed.
Pressure is applied to the other side of the sensor.

LEVEL
The transmitter is available as a flange mounted unit with a
flush diaphragm, for direct installation on vessels.
Extended diaphragms are also available.
For food grade applications, see SR301 series catalog.

REMOTE SEALS
Separate diaphragm seals are installed in either one or in
both sides of the sensor, providing further chemical and
thermal isolation.
For food grade applications, Tri-clamp and other
connections according 3-A standard compliant
connections are available. See SR301 series catalog.

5 smar
PROGRAMMING AND ADJUSTMENT

CONF401 - CONFIGURATION SOFTWARE

The LD301 can be programmed by a Hand-Held Terminal


or PC (Personal computer) using the software CONF301,
together with a SMAR HI311 interface (HART/RS232C).

The CONF401 is a configuration interface developed


under the application MS Windows, so the human
machine interface is extremely friendly.

Programming, reranging, PID adjustment (optional), setpoint


changing, etc. are performed by both the Hand-Held
Terminal and CONF401, when connected in parallel to
any point of the 4-20 mA line. A single Hand-Held Terminal
or computer can be used for programming any number of
transmitters.

The local adjustment using the magnetic screwdriver


allows, besides the zero and span adjustments, setpoint
and other controller functions changing, totalization
enabling, trim adjustments, etc.

INTERFACE
HI311

HPC301
LOCAL
CONF401 - CONFIGURATION SOFTWARE
ADJUSTMENT

CONNECTION DIAGRAM
POWER SUPPLY

AND
OR

For proper operation, the Hand-Held Terminal LD301 SERIES


requires a minimum load of 250 Ohms between TRANSMITTER
the power supply and the transmitter.
LAP TOP

smar 6
APPLICATIONS

Working as a Conventional Transmitter Working as a Local Controller

FIC
POWER SUPPLY 4-20 mA POWER SUPPLY
INPUT 4-20 mA

CONTROL ROOM OUTPUT 4-20 mA


PLANT FLOOR
4-20 mA

LT

I/P I/P

LV
LV

Working as a Controller with Computer Supervision from the Control Room

POWER SUPPLY
INTERFACE

250Ω

CONTROL ROOM

PLANT FLOOR

4-20 mA 4-20 mA 4-20 mA

FT PT FT

FV PV FV

7 smar
TECHNICAL CHARACTERISTICS

Functional Specifications NEW Failure Alarm


In case of sensor or circuit failure, the self diagnostics
Process Fluid drives the output to 3.6 or 21.0 mA, according to the user’s
Liquid, gas or vapor. choice.
Turn-on Time
Output Signal Performs within specifications in less than 5.0 seconds
NEW Two-wire, 4-20 mA controlled according to NAMUR NE43
after power is applied to the transmitter.
Specification, with superimposed digital communication (HART®
Protocol). Volumetric Displacement
Less than 0.15 cm3 (0.01 in3).
Power Supply
12 to 45 Vdc. Overpressure and Static Pressure Limits
From 3.45 kPa abs. (0.5 psia)* to:
Load Limitation 8 MPa (1150 psi) for range 1.
16 MPa (2300 psi) for ranges 2, 3 & 4.
1650
1500
32 MPa (4600 psi) for models H & A5.
40 MPa (5800 psi) for model M5.
rea 52 MPa (7500 psi) for model M6.
ga
ratin
Load [Ohm]

1000 e
Op * except the LD301A model.
Flange Test Pressure: 60 MPa (8570 psi).
500
4-20 mA and Digital Communication For ANSI/DIN Level flanges (LD301L models):
250 150lb: 6 psia to 275 psi at 38 °C (-0.6 to 19 bar).
4-20 mA only
0 300lb: 6 psia to 720 psi at 38 °C (-0.6 to 50 bar).
17
12 20 30 40 45
PN10/16: -60 kPa to 1.4 MPa at 120 °C.
Power Supply [Volt]
PN25/40: -60 kPa to 4 MPa at 120 °C.

Indicator These pressures will not damage the transmitter, but a new
Optional 4½-digit numerical and 5-character alphanumerical LCD calibration may be necessary.
indicator.
Humidity Limits
Hazardous Area Certifications 0 to 100% RH.
Explosion proof, weather proof and intrinsically safe
(NEMKO, DMT, CEPEL, CSA and FM standards). Damping Adjustment
User configurable from any value higher than zero seconds in addition
Zero and Span Adjustments to intrinsic sensor response time (0.2s) (via digital communication).
Noninteractive, via digital communication.
Configuration
Zero Adjustment Limits Can be done through digital communication using the Hart
Protocol or, partially, through local adjustment.
I (mA)

2 0 Performance Specifications
Reference conditions: range starting at zero, temperature 25 °C (77 °F),
atmospheric pressure, power supply of 24 Vdc, silicone oil fill fluid, isolating
diaphragms in 316L SS and digital trim equal to lower and upper range
values.
4

ELEVATION SUPPRESSION Accuracy


LRL 0.9915 URL URL 0.1 URL ≤ span ≤ URL:
LRL = LOWER RANGE LIMIT URL = UPPER RANGE LIMIT ±0.075% of span;
0.025 URL ≤ span ≤ 0.1 URL:
Calibrated span shall not be less than 0.0085 URL and shall not exceed 2 URL. ±0.0375 [1+0.1 URL/span]% of span;
Low range value shall not be below LRL. 0.0085 URL ≤ span ≤ 0.025 URL:
Upper range value shall not be greater than URL.
±[0.0015+0.00465 URL/span]% of span (*).
(LRL = -URL for all models, except absolute, where LRL = vacuum).
(*) - Recommended minimum span for Range 1 is 0.025 URL.
For ranges 5 and 6, Absolute models, diaphragms in Tantalum,
Temperature Limits Monel or fill fluid in Fluorolube:
Ambient: -40 to 85 °C (-40 to 185 °F). 0.1 URL ≤ span ≤ URL:
Process: -40 to 100 °C (-40 to 212 °F) (Silicone Oil). ± 0.1% of span;
0 to 85 °C (-32 to 185 °F) (Fluorolube Oil). 0.025 URL ≤ span ≤ 0.1 URL:
-40 to 150 °C (-40 to 302 °F) for LD301L. ±0.05 [1+0.1 URL/span]% of span;
-25 to 85 °C (-13 to 185 °F) (Viton O-Rings). 0.0085 URL ≤ span ≤ 0.025 URL:
±[0.01+0.006 URL/span]% of span.
Storage: -40 to 100 °C (-40 to 212 °F).
Digital Display: -10 to 60 °C (14 to 140 °F). For Absolute - range 1:
-40 to 85 °C (-40 to 185 °F) without damage. ± 0.2% of span
Linearity, hysteresis and repeatability effects are included.

smar 8
Stability Nonwetted Parts
± 0.1% of URL for 24 months for ranges 2, 3, 4, 5 & 6. • Electronic Housing
± 0.2% of URL for 12 months for range 1 & L models. Injected aluminum with polyester painting or 316 SST
± 0.25% of URL for 5 years, at 20 °C temperature change (NEMA 4X, IP67).
and up to 7 MPa (1000 psi) of static pressure.
• Blank Flange
Temperature Effect Plated carbon steel, when the wetted flange is made
± (0.02% URL+0.1% span) per 20 °C (36 °F) for ranges 2, 3, of this same material, and 316 SST in the other cases.
4, 5 & 6.
± (0.05% URL+0.15% span) per 20 °C (36 °F) for range 1. • Level Flange (LD301L)
316 SST.
For LD301L:
6 mmH2O per 20 °C for 4" and DN100. • Fill Fluid
Silicone or Fluorolube Oil.
17 mmH2O per 20 °C for 3" and DN80.
Consult for other flange dimensions and fill fluid. • Cover O-Rings
Buna N.
Static Pressure Effect
Zero error: • Mounting Bracket
± 0.1% URL per 7 MPa (1000 psi) for ranges 2, 3, 4 & 5, or Plated carbon steel with polyester painting or 316 SST.
3.5 MPa (500 psi) for L models or 1.7 MPa (250 psi) for Accessories (bold, nuts, washers and U-clamps) in
range 1. This is a systematic error that can be eliminated by carbon steel or 316 SST.
calibrating at the operating static pressure.
Span error: • Flange Bolts and Nuts
Correctable to ± 0.2% of reading per 7 MPa (1000 psi) for Plated carbon steel:
ranges 2, 3, 4 & 5 or 3.5 MPa (500 psi) for range 1 and L Grade 7, 316 SST or Carbon Steel B7M (for nace
models. applications).
Power Supply Effect • Identification Plate
± 0.005% of calibrated span per volt. 316 SST.
Mounting Position Effect
Mounting
Zero shift of up to 250 Pa (1 inH2O) which can be calibrated
a) Flange mounted for models LD301L.
out. No span effect.
b) Optional universal mounting bracket for surface
Electro-Magnetic Interference Effect or vertical/horizontal (DN 50) 2"-pipe (optional).
Designed to comply with IEC 61000-6-2:1999, c) Via bracket on manifold valve (optional).
IEC 61000-6-4: 1997, IEC 61326: 2000. d) Directly on piping for closely coupled transmitter/orifice
flange combinations.
Vibration Effects
Designed according to SAMA PMC 31.1 standard Approximate Weights
3.15 kg (7 lb): all models, except L models.
Physical Specifications 5.85 to 9.0 kg (13 lb to 20 lb): L models depending on the
Electrical Connection flanges, extension and materials.
½ - 14 NPT, Pg 13,5 or M20 x 1,5 metric.
Control Characteristics (optional)
Process Connection PID
¼ - 18 NPT or ½ -14 NPT (with adapter). For L models see Proportional Gain: 0 to 100.
ordering code. lntegral Time: 0.01 to 999 min/rep.
Derivative Time: 0 to 999 s.
Wetted Parts Direct / Reverse Action.
• Isolating Diaphragms Lower and Upper output limits.
316L SST, Hastelloy C276, Monel 400 or Tantalum. Output rate-of-change limit: 0 to 100%/s.
• Drain/Vent Valves and Plug Power-on safety output.
316 SST, Hastelloy C276 or Monel 400. Antireset windup.
Bumpless Auto/Manual transfer.
• Flanges 16 point table for PID input and output, freely user configurable.
Plated carbon steel, 316 SST, Hastelloy C276
or Monel 400. Hastelloy is a trademark of the Cabot Corp.
Monel is a trademark of International Nickel Co.
• Wetted O-Rings (For Flanges and Adapters) Viton and Teflon are trademarks of E. I. DuPont de Nemours & Co.
Buna N, VitonTM or PTFE. Ethylene-Propylene on Fluorolube is a trademark of Hooker Chemical Corp.
Hart is a trademark of HART Communication Foundation.
request.
Smar Pressure Transmitters are protected by USA patent number 6,433,791
The LD301 is available in NACE MR-01-75 compliant
materials.

9 smar
ORDERING CODE

MODEL
DIFFERENTIAL, GAGE, ABSOLUTE AND HIGH STATIC PRESSURE TRANSMITTERS
LD301
CODE Type and Range (1)
D1 Differential 0.125 to 5 kPa 0.5 to 20 inH2O
D2 Differential 0.417 to 50 kPa 1.67 to 200 inH2O
D3 Differential 2.08 to 250 kPa 0.3 to 36 psi
D4 Differential 20.8 to 2500 kPa 3 to 360 psi

M1 Gage 0.125 to 5 kPa 0.5 to 20 inH2O


M2 Gage 0.417 to 50 kPa 1.67 to 200 inH2O
M3 Gage 2.08 to 250 kPa 8.33 to 1000 inH2O
M4 Gage 20.8 to 2500 kPa 3 to 360 psi
M5 Gage 0.208 to 25 MPa 30 to 3600 psi
M6 Gage 0.333 to 40 MPa 48.3 to 5800 psi

A1 Absolute 2 to 5 kPa 14.8 to 37 mmHga


A2 Absolute 2.5 to 50 kPa 0.36 to 7.2 psia
A3 Absolute 5 to 250 kPa 0.3 to 36 psia
A4 Absolute 20.8 to 2500 kPa 3 to 360 psia
A5 Absolute 0.208 to 25 MPa 30 to 3600 psia

H2 Differential - High Static Pressure 0.417 to 50 kPa 1.67 to 200 inH2O


H3 Differential - High Static Pressure 2.08 to 250 kPa 0.3 to 36 psi
H4 Differential - High Static Pressure 20.8 to 2500 kPa 3 to 360 psi
H5 Differential - High Static Pressure 0.208 to 25 MPa 30 to 3600 psi
CODE Diaphragm Material and Fill Fluid (Low Side)
1 316L SST Silicone Oil
2 316L SST Fluorolube Oil
3 Hastelloy C276 Silicone Oil*
Note: Absolute Models are not available with Fluorolube Oil.
4 Hastelloy C276 Fluorolube Oil*
Tantalum and Monel diaphragm are not available for Range 1.
5 Monel 400 Silicone Oil
7 Tantalum Silicone Oil
8 Tantalum Fluorolube Oil
Z Others - Specify
CODE Flange(s), Adapter(s) and Drain/Vent Valves Materials

C Plated CS (Drain/Vent in Stainless Steel)


I 316 SST
H Hastelloy C276*
M Monel 400
N 316 SST (Drain/Vent in Hastelloy C276)*
Z Others - Specify

CODE Wetted O-Rings Materials


0 Without O-Rings
B Buna N
V Viton Note: O-Rings are not available on sides with Remote Seals.
T Teflon
Z Others - Specify
CODE Drain/Vent Position
0 Without Drain/Vent Note: For better drain/vent operation, vent valves are strongly recommended.
U Upper Drain/Vent valve not available on sides with Remote Seals.
D Lower
CODE Local Indicator
0 Without Indicator
1 With Digital Indicator
CODE Process Connections
0 ¼ - 18 NPT (Without Adapter)
1 ½ - 14 NPT (With Adapter)
9 Remote Seal (Specify)
V Valve manifold integrated to the transmitter
Z Others - Specify

CODE Electrical Connections


0 ½ - 14 NPT
A M20 x 1,5
B Pg 13,5 DIN
Z Others - Specify
CODE Zero and Span Adjustments
1 With Local Adjustments
CODE Mounting Bracket for 2” Pipe or Surface Mounting
0 Without Bracket
1 Carbon Steel Bracket
2 316 SST Bracket
7 Carbon Steel bracket with 316 SST fasteners
CODE Optional Items **
H1 316 SST Housing
A1 316 SST Bolts and Nuts
C1 Special Cleaning
ZZ Special Options - Specify

LD301 - D2 1 I - B U 1 0 - 0 1 2 / ** TYPICAL MODEL NUMBER

(1) The range can be extended up to 0.75 LRL and 1.2 URL with small degradation of accuracy.
* Meets NACE material recommendations per MR-01-75
** Leave it blank for no optional items

smar 10
ORDERING CODE

MODEL
LEVEL TRANSMITTERS
LD301
CODE Range
L2 Level 1.25 to 50 kPa 5 to 200 inH20
Note: The range can be extended up to 0.75 LRL and 1.2 URL with small degradation of accuracy.
L3 Level 2.08 to 250 kPa 8.33 to 1000 inH20
The Upper Range Value must be limited to the flange rating.
L4 Level 20.8 to 2500 kPa 3 to 360 psi
CODE Diaphragm Material and Fill Fluid (Low Side)
1 316 SST Silicone Oil 7 Tantalum Silicone Oil
2 316 SST Fluorolube Oil 8 Tantalum Fluorolube Oil
3 Hastelloy C276 Silicone Oil* Z Others - Specify
4 Hastelloy C276 Fluorolube Oil*
5 Monel 400 Silicone Oil
CODE Flange, Adapter and Drain/Vent Valves Material (Low Side)
C Plated CS (Drain/Vent in Stainless Steel)
I 316 SST
H Hastelloy C276*
M Monel 400
N 316 SST (Drain/Vent in Hastelloy C276)*
Z Others - Specify
CODE Wetted O-Rings Material (Low Side)
0 Without O-Rings (Remote Seal)
B Buna N
V Viton
T Teflon
Z Others - Specify
CODE Drain/Vent Position (Low Side)
0 Without Drain/Vent
Note: For better drain/vent operation, the side vent or drain valves are standard.
U Upper
If drain/vent valves are not required, use code 0.
D Lower
CODE Local Indicator
0 Without Indicator
1 With Digital Indicator
CODE Process Connection (Low Side)
0 ¼ - 18 NPT (Without Adapter)
1 ½ - 14 NPT (With Adapter)
9 Remote Seal (Specify)
Z Others - Specify
CODE Electrical Connection
0 ½ - 14 NPT
A M20 x 1,5
B Pg 13,5 DIN
Z Others - Specify
CODE Zero and Span Adjustments
1 With Local Adjustment
CODE Process Connection (High Side)
1 3” 150# (ANSI B16.5 RF) 9 2” 150# (ANSI B16.5 RF)
2 3” 300# (ANSI B16.5 RF) A 2” 300# (ANSI B16.5 RF)
3 4” 150# (ANSI B16.5 RF) B 2” 600# (ANSI B16.5 RF)
4 4” 300# (ANSI B16.5 RF) C 3” 600# (ANSI B16.5 RF)
6 DN 80 PN 25/40 D 4” 600# (ANSI B16.5 RF)
7 DN 100 PN 10/16 E DN 50 PN 10/40
8 DN 100 PN 25/40 Z Others - Specify
CODE Flange Material (Level Tap)
2 316 SST
Z Others - Specify
CODE Extension Length
0 0 mm
1 50 mm (2”)
2 100 mm (4”)
3 150 mm (6”)
4 200 mm (8”)
Z Others - Specify
CODE Diaphragm Material (High Side)
1 316L SST
2 Hastelloy C276*
3 Monel 400**
4 Tantalum Note: With 316 SST extension.
5 Titanium
Z Others - Specify
CODE Fill Fluid (High Side)
1 DC200 Silicone Oil
2 Fluorolube Oil
3 DC704 Silicone Oil
A DC200/350 Silicone Oil - Food Grade
Z Others - Specify
CODE Optional Items ***
H1 316 SST Housing
AI 316 SST Bolts and Nuts
C1 Special Cleaning
ZZ Special Options - Specify

LD301 - L2 1 I - B U 1 0 - 0 1 - 1 2 2 1 1 / *** TYPICAL MODEL NUMBER

* Meets NACE material recommendations per MR-01-75.


** Fluorolube fill fluid is not avaliable for Monel Diaphragm.
*** Leave it blank for no optional items.
11 smar
DIMENSIONS

Allow 150mm minimum for local zero


113 Dimensions are mm (in)
and span adjustment with magnetic tool
(4.44)

Electrical Connection
(Both Sides)

(∅3.26)
∅83
TERMINAL
Mounting

(3.81)
CONNECTION

97
Bracket

186,5
(7.34)
(7.12)
181

(1.62)
41,3

(3.7)
94
47,5 72,5 54* DN-50
(1.87) (2.85) (2.13) (Tubo 2")
100,5 179
(3.95) (7.04)
* 56 mm (2.20in) for D4-H4 models
113 * 57.2 mm (2.25in) for H5 model 83
(4.44) (3.26)
(∅3.26)

(3.81)
∅83

97

Screw
(7.16)
182

1/2 - 14 NPT
With Adapters Dimensions for LD301L
Nominal N Bolt
O

Rating A B C E
Flange Size Holes
∅B
∅C

2" 150 lb 152 92 48 22 4


∅A

Vent / Drain
2" 300 lb 165 92 48 23 8
2" 600 lb 165 92 48 32 8
1/2 - 18 NPT 3" 150 lb 190 127 73 24 4
Without Adapters 3" 300 lb 210 127 73 29 8
4" 150 lb 229 157 96 24 8
Label 1/4 - 18 NPT
Without Adapter 4" 300 lb 254 157 96 32 8
DN50 PN10/40 165 102 48 22 4
Level Diaphragm
DN80 PN25/40 200 138 73 24 8
DN100 PN10/16 220 157 96 22 8
72,5 E DN100 PN25/40 235 162 96 24 8
(2.85) Dimension "D" - Extension: 0, 50, 100, 150 or 200 mm
100,5 D 173 27
(3.95) (6.81) (1.06)

USA GERMANY
Smar International Corporation Smar Research Corporation Smar Laboratories Corporation Smar GmbH
6001 Stonington Street, Suite 100 4250 Veterans Memorial Hwy.Suite 156 10960 Millridge North, Suite 107 Rheingaustrasse 9
Houston, TX 77040 Holbrook , NY 11741 Houston, TX 77070 55545 Bad Kreuznach
Tel.: +1 713 849-2021 Tel.: +1 631 737-3111 Tel.: +1 281 807-1501 Tel: + 49 671-794680
Fax: +1 713 849-2022 Fax: +1 631 737-3892 Fax: +1 281 807-1506 Fax: + 49 671-7946829
e-mail: sales@smar.com e-mail: sales@smarresearch.com e-mail: smarlabs@swbell.net e-mail: infoservice@smar.de

FRANCE MEXICO BRAZIL CHINA


Smar France S. A. R. L. Smar Mexico Smar Equipamentos Ind. Ltda. Smar China Corp.
42, rue du Pavé des Gardes Cerro de las Campanas #3 desp 119 Rua Dr. Antonio Furlan Jr., 1028 3 Baishiqiao Road, Suite 30233
F-92370 Chaville Col. San Andrés Atenco Sertãozinho SP 14170-480 Beijing 100873, P.R.C.
Tel.: +33 1 41 15-0220 Tlalnepantla Edo. Del Méx - C.P. 54040 Tel.: +55 16 3946-3510 Tel.: +86 10 6849-8643
Fax: +33 1 41 15-0219 Tel.: +52 555 378 4600 al 02 Fax: +55 16 3946-3554 Fax: +86 10 6894-0898
e-mail: smar.adm@wanadoo.fr Fax: +52 555 378 4603 e-mail: smarinfo@smar.com e-mail: info@smar.com.cn
e-mail: ventas@smar.com

SINGAPORE ARGENTINA Plus a network of


Smar Singapore Pte. Ltd. Smar Argentina representatives in 58 countries.
315 Outram Road Soldado de La Independencia, 1259 For your nearest representative
#06-07, Tan Boon Liat Building (1429) Capital Federal - Argentina please contact:
Singapore 169074 Telefax: 00 (5411) 4776-1300 / 3131 smarinfo@smar.com
Tel.: +65 6324-0182 e-mail: smarinfo@smarperifericos.com
Fax: +65 6324-0183
e-mail: info@smar.com.sg

www.smar.com
© Copyright 2003 - Smar International - all rights reserved. - September/2003