You are on page 1of 15

NEC Confidential

EQUIPMENT CONFIGURATION (1 of 5)

Page 2

PT. NEC Indonesia 2010

NEC Confidential

EQUIPMENT CONFIGURATION (2 of 5)

Equipment Name
Equipment Configuration shows
the mounted option boards.

Connected ODU
information and IDU
(Modem) Settings

Modem SW/ XPIC GRP Configuration


shows how the Modem 1 and 2 are used.

Adaptive Modulation
Radio Settings

Page 3

PT. NEC Indonesia 2010

NEC Confidential

EQUIPMENT CONFIGURATION (3 of 5)
2 (1+0) Configuration

(1+0) Configuration
(1+1) Hot Standby
Configuration

Equipment Current status

Page 4

PT. NEC Indonesia 2010

NEC Confidential

(1+0) XPIC Configuration

EQUIPMENT CONFIGURATION (4 of 5)

1 Click on the Setup Icon to open the setup 1 Setting of Equipment

Name window.
Left side shows the current setting. Click on the Equipment Name
field in the New setting in the right hand of the window. And enter the
new name. (up to 32 characters)
If you exceed the number of characters, the entry field border turns to
red and when the cursor is moved to the entry field pop up will show
the limits
2

Click on the Next Button to go to next setting


window. If the name field characters exceed,
Input Error warning popup appears.

Page 5

PT. NEC Indonesia 2010

Setting of SW/ XPIC Group window allows setting of how the two
modems are used. For (1+1) configuration click on the check box
SW/ XPIC GRP and click on the drop down arrow and select the
required option. Other wise click on modem 1 or modem 2 and select
used or not used.
Click the Next button to go to the next setting window

NEC Confidential

EQUIPMENT CONFIGURATION (5 of 5 )

Modifications to be
applied are highlighted

Click the OK button to


apply the changes

Following warning ask to


confirm the change, click
to continue OK
Information window show
the changes complete,
click OK

Page 6

PT. NEC Indonesia 2010

NEC Confidential

RADIO CONFIGURATION (1 of 4 )
Item
Channel
Spacing
Reference
Modulation
Radio Mode
E1 Mapping

Modem configuration

Page 7

PT. NEC Indonesia 2010

STM-1
Mapping
ETH
Bandwidth
TX RF
Frequency
RX RF
Frequency
Frame ID
TX Power
Control

NEC Confidential

Parameter
7/14/28/56 [MHz]

Description
Specify the radio channel
spacing
QPSK
Specify the reference
16/32/64/128/256[QAM] modulation from the list
Specify the Radio Mode
High Capacity/ High
System Gain
0 to 152 [CH]
Specify the number of E1
CH for mapping. (The
number of CH should not
exceed the limitation of the
specified modulation.)
0 to 1 [CH]
Specify the number of STM1 CH for mapping.
[Mbps]
Display the bandwidth of
the ether traffic
xxxxx.xxx [MHz]
Enter transmit frequency
xxxxx.xxx [MHz]
1 - 32
MTPC/ATPC

receive frequency
(automatically)
Set frame ID
Set transmit power control
mode

RADIO CONFIGURATION (2 of 4)
Click the Equipment Setup Menu and select
Radio Configuration to open the Equipment
Setup Radio configuration window.
Click the Setup Icon to open the Setup 1 Detailed MODEM
Setting of SW/XPIC GRP or Slot Unit window.
Radio configuration window shows
the existing radio configuration
including the ODU frequency,
parameters of radio channel 1 and 2.

Modem 1 and 2 configuration

Page 8

PT. NEC Indonesia 2010

NEC Confidential

RADIO CONFIGURATION (3 of 4)
Specification and information of the ODU
connected to the selected Modem
Green border on the Set
Position section modem
configuration show the
selected modem

Select the channel spacing of


the radio signal

Select the reference Modulation


of the radio signal

Radio Mode: select High capacity or


High system Gain. High system gain
is achieved by better FEC.

Current setup of the selected


modem s radio configuration

Select the number of E1 channels


to be used
Select the number of STM-1
channels to be used (need STM-1
optional Interface card )
Show the available Ether bandwidth
after E1 and STM-1 traffic mapping.

Select the TX Power Control Mode.


ATPC or MTPC. Parameter setting for
each mode is from provisioning menu

Page 9

PT. NEC Indonesia 2010

NEC Confidential

Enter TX/RX point frequency within the


Start and Stop frequency of the ODU
shown above.
Enter the radio signal Frame ID (1 ~ 32)

RADIO CONFIGURATION (4 of 4)

Select the Channel spacing to be used from the drop down list
Select the Reference or fixed modulation to be used from the
drop down list
Change the setting for Modem 2
and click the Next button

Select the High system Gain or High Capacity


Select the maximum number of E1 to be used
Select whether STM-1 is to be used in the through mode

Changed parameters are highlighted in blue.


Confirm the changes and click the Ok button

Confirm the available Ether band width


Set the TX & RX Frequency
Select the Frame ID to be used (1 ~ 32)
TX Power control mode ATPC or MTPC
After changing the setting for Modem 1 and click the Next
button

Page 10

PT. NEC Indonesia 2010

NEC Confidential

AMR Configuration (1 of 4)

Set the AMR Modulation for Modem 1 & Click Next

Show the current Configuration for Modem 1 and 2

Item
E1 Mapping

Parameter
QPSK
16 QAM
32 QAM

- E1 Mapping (Range: 0 - 152)

64 QAM

- STM-1 Mapping (Range: 0 - 1)

128 QAM

- ETH Bandwidth is calculated from E1 and

256 QAM

Set the AMR priority traffic for Modem 1 & Click Next to set the Modem 2.

Page 11

PT. NEC Indonesia 2010

NEC Confidential

Select following items.

STM-1 mapping

AMR CONFIGURATION (2 of 4)
Select AMR Operation by clicking the AMR Mode radio button.
Select Non Operation radio button not to use the AMR function
Reference Modulation selected in Equipment Setup is shown
highlighted in green.
Select the other modulations to be used during AMR operation
by selecting the appropriate Used radio button
Click the Next button to set the E1 / STM-1 mapping.

E1/STM-1 Mapping Settings:


Priorities for preservation of traffic (E1/STM1/Ethernet) as
modulation level (and therefore transmission capacity)
decreases
Enter the priority E1 channels to be used for each modulation
during the AMR operation in E1 Mapping for each modulation

If STM-1 through mode is used select which modulation


schemes to be used during AMR operation provided that the
radio capacity is available.
Capacity remaining for Ethernet bandwidth is shown
automatically.
Click the Next button to set the AMR operation and E1/STM-1
mapping for Modem 2.

Page 12

PT. NEC Indonesia 2010

NEC Confidential

AMR CONFIGURATION (3 of 4)

SET E1/STM-1 MAPPING FOR MODEM-1

SET AMR FOR MODEM-1

SET AMR FOR MODEM-2

AMR CONFIRMATION SCREEN

Page 13

PT. NEC Indonesia 2010

SET E1/STM-1 MAPPING FOR MODEM-2

NEC Confidential

AMR CONFIGURATION (4 of 4)

Page 14

PT. NEC Indonesia 2010

NEC Confidential

You might also like