You are on page 1of 25

Intelligent

Carrier
Power
Off/On Feature Guide
WCDMA RAN

Intelligent Carrier Power Off/On Feature Guide

Intelligent Carrier Power Off/On Feature Guide


Version

Date

Author

Reviewer

Revision History
1.

According to ZTE UMTS Node B


Management Feature
Guide_V6.0_201110.docx, added the
description of intelligent carrier power
off/on based on the number of users in a
cell.

7.0

2012-4-20

He Chao

Xu Junping

2.

In section 2.1, modified maximum


transmit power to CPICH power.

3.

In section 3.1.1, modifies the description


of the timer.

4.

In section 3.2.1, modified < to <= in


the formula .

1.

CloseFreFunSwit is modified from cell


level to RNC level, and related
description is modified.

2.

Added three parameters omitted in the


previous revision: PcpiPwrDnStep,

8.0

2013-04-28

He Chao

Xu Junping

PcpiPwrDnTmWin, and
PcpiPwrDnStepTm.

8.5

2013-11-28

Zhang
Haiyan

3.

Supplemented "3.3

Carrier Power off".

4.

Modified the counters.

1.

Corrected edit errors.

2.

Added Feature ID

Xu Junping

2014 ZTE Corporation. All rights reserved.


ZTE CONFIDENTIAL: This document contains proprietary information of ZTE and is not to be disclosed or used
without the prior written permission of ZTE.
Due to update and improvement of ZTE products and technologies, information in this document is subjected to
change without notice.

ZTE Confidential Proprietary

Intelligent Carrier Power Off/On Feature Guide

TABLE OF CONTENTS
1

Feature Attributes.............................................................................................. 4

2
2.1

Overview ............................................................................................................ 4
ZWF21-20-017 Intelligent Carrier Power Off/On .................................................. 4

3
3.1
3.1.1
3.1.2
3.2
3.3
3.4

Technical Descriptions ..................................................................................... 5


Carrier Power-Off Checking Strategies ................................................................ 5
Strategy Based on the Number of In-Cell Users................................................... 5
Strategy Based on Cell Load ............................................................................... 6
Carrier Power-On Checking Strategies ................................................................ 8
Carrier Power Off Procedure .............................................................................. 10
Carrier Power On Procedure .............................................................................. 11

4
4.1
4.1.1
4.1.2

Parameters and Configurations ..................................................................... 11


Intelligent Carrier Power Off/On Parameters ...................................................... 11
Intelligent Carrier Power off/on Parameters List ................................................. 11
Intelligent Carrier Power Off/On Parameters Configurations .............................. 12

5
5.1
5.2

Counters and Alarms ...................................................................................... 23


Counters List...................................................................................................... 23
Alarms List ......................................................................................................... 23

Glossary ........................................................................................................... 24

ZTE Confidential Proprietary

Intelligent Carrier Power Off/On Feature Guide

FIGURES
Figure 3-1 Flow Chart for Carrier Closing Decision ............................................................. 6
Figure 3-2 Carrier Power Off Procedure.............................................................................10

ZTE Confidential Proprietary

Intelligent Carrier Power Off/On Feature Guide

Feature Attributes
System version: [RNC V4.11.20, Node B V4.12.10, OMMR V12.12.41, and OMMB
V12.12.40 ]
Attribute: [Optional]
Involved NEs:
UE
-

Node B

RNC

MSCS
-

MGW
-

SGSN
-

GGSN
-

HLR
-

Note:
*-: Not involved
* : Involved
Dependency: [None]
Mutually exclusion: [None].
Note: [None]

Overview

2.1

ZWF21-20-017 Intelligent Carrier Power Off/On


The load in a mobile telecommunication system varies during a day. In rush hours,
multiple carries may be required to carry services. But late at night, one carrier may be
enough to satisfy the service demand. If multiple carriers are used when the traffic is low,
the load of each carrier is low but still occupies about 20% of the maximum transmit
power due to the transmission of common channels (such as pilot channels).
This feature is designed to automatically monitor the network traffic and close part
carriers when the traffic is low. If it is detected that the traffic increases and may exceed
the handling capacity of the current working carriers, the closed carriers are
automatically opened.

ZTE Confidential Proprietary

Intelligent Carrier Power Off/On Feature Guide

During the intelligent carrier closing period, the P-CPICH power of the cell is reduced
gradually until the cell is completely closed, and the services of the cell are handed over
to the adjacent cell smoothly.

Technical Descriptions
In a multi-carrier network, the operator can enable or disable the Intelligent Carrier Power
Off/On feature via the RNC-level switch closeFreFunSwit.
When closeFreFunSwit is set to On, if the number of subscribers or load at a carrier is
low, the RAN automatically closes the carrier to save power. The power of pilot channel
is reduced gradually to avoid call drops when the carrier is being closed. The subscribers
in this cell are handed over to other carriers based on radio quality. If the working carrier
is in congestion, the RAN immediately opens the closed carrier.

3.1

Carrier Power-Off Checking Strategies


There are two algorithms for intelligent carrier power off checking, one is based on the
number of users in the cell, and the other is based on the cell load. Operators can
choose either algorithm via the parameter closeFreAlg for each cell.
freCloseAllowedInd is used to control whether the current carrier is allowed to be closed.
This parameter is configured for each cell.

When freCloseAllowedInd is equal to 0, the current carrier is not allowed to be closed.


The network planning personnel must ensure that the first carrier (which is used to
provide continuous coverage) is not allowed to be closed.

3.1.1

When freCloseAllowedInd is equal to 1, the current carrier is allowed to be closed.

Strategy Based on the Number of In-Cell Users


When closeFreFunSwit is set to on, for the cells for which carriers are allowed to be
closed (indicated by freCloseAllowedInd) and the closeFreAlg is set as Based on the
User Number on CELL_DCH State to Switch Off Frequency, the RNC checks whether

ZTE Confidential Proprietary

Intelligent Carrier Power Off/On Feature Guide

the condition is fulfilled for closing carriers during the time between startTimetoClsF and
endTimetoClsF.
When the time indicated by startTimetoClsF is reached, the RNC counts the number of
subscribers in Cell_DCH state in the cell. If the number is lower than the threshold
indicated by ueNumThreshCls in the duration indicated by freClsOpnTrigTm, a carrier
closing procedure is triggered.
Figure 3-1 shows the decision procedure for carrier closing.

Figure 3-1

Flow Chart for Carrier Closing Decision

The time indicated by


startTimetoClsF is reached?
Y

Count the number of


users (UserNum) in
Cell_DCH

UserNum < ueNumThreshCls?


Y

Start the timer


CellCloseTime
(initial value =
freClsOpnTrigTm)

UserNum is decreased?
Y
N

UserNum is greater than or


equal to ueNumThreshCls
before CellCloseTimer expires?
Y

Start closing the


carrier

3.1.2

Stop the timer


CellCloseTime

Strategy Based on Cell Load


When there are many flat tariff users in the network, who are always online for 24 hours a
day to download audio or video., Intelligent Carrier Power Off/On Based on the Number

ZTE Confidential Proprietary

Intelligent Carrier Power Off/On Feature Guide

of In-Cell Users is hard to take effect. Intelligent Carrier Power Off/On Based on Cell
Load is presented, which allows the carrier to be closed when the remained carriers can
fulfill the current users basic QoS requirement.
In the scenario of multi-layer, the RNC sets a priority for each carrier according to the
strategy of Intelligent Carrier Power Off/On Checking Based on Cell Load. The priority is
indicated by freClosePri, which can be configured for each cell according to the
operators requirement.
In a certain area covered by multi-layer cells (having Overlap or Covers relationship
indicated by ShareCover), the selection of the carrier to be closed always begins from
the cell with the lowest priority. If more than one cell has the same priority, the one with
the fewest users in CELL_DCH state is selected. If more than one cell has the same
number of users in CELL_DCH state, the one with the smallest Cell ID is selected.
When closeFreFunSwit is set to on, for the cell for which the carrier is allowed to be
closed (indicated by freCloseAllowedInd) and the closeFreAlg is set as Based on the
Cell Load to Switch Off Frequency, the RNC checks whether the condition is fulfilled for
closing a carrier during the time between startTimetoClsF and endTimetoClsF.
In order to guarantee that the load of the current cell can be carried by neighboring cells,
cell resources are all evaluated before the carrier closing. The carrier closing is triggered
only if all the resources fulfill the following condition in the duration indicated by
freClsOpnTrigTm:
Effective load of the cell to be closed <= (Admission threshold of the neighboring cells
with Overlap or Covers relationship - LoadMarginClose current resource consumption
of the neighboring cells with Overlap or Covers relationship
LoadMarginClose is the load margin configured respectively for different kinds of cell
resources. For the downlink transmit power, uplink interference, channelization code,
uplink CE resource, downlink CE resource, number of users on HSDPA, and the number
of

users

on

HSUPA,

powerMarginClose,

the

corresponding

intMarginClose,

LoadMarginClose

codeMarginClose,

parameters

are

ulCeMarginClose,

dlCeMarginClose, hsNumMarginClose, and eNumMarginClose respectively.


The parameter freClsCeEvaInd is used to control whether CE resources are evaluated.

ZTE Confidential Proprietary

Intelligent Carrier Power Off/On Feature Guide

Note: The carrier cannot be closed if there is a neighboring cell with Overlap or Covers
relationship in congestion.

3.2

Carrier Power-On Checking Strategies


After a carrier is closed via this feature, there are four algorithms to power on the cell.
Which algorithm is adopted depends on the parameter openFreAlg.

If the value of openFreAlg is 0, the algorithm based on time is adopted. When the
time indicated by endTimetoClsF is reached, the intelligently closed cell is opened.

If the value of openFreAlg is 1, the algorithm based on congestion is adopted. If the


working carrier is in congestion, the RNC opens all the closed adjacent cells.
Whether the cell is congested is determined by the congestion algorithm. Refer to
the congestion control feature guide.

If the value openFreAlg is 2, the algorithm based on time or congestion is adopted.

If the value of openFreAlg is 3, the algorithm based on time or cell load is adopted.

When either of the following conditions is fulfilled, the closed carrier is switched on
immediately.
Condition 1: The time indicated by endTimetoClsF is reached.
Condition 2: (Effective load of the working carrier) > (Admission threshold of the
working carrier - LoadMarginOpen).
LoadMarginOpen is the load margin configured respectively for different kinds of
resources. For the downlink transmit power, uplink interference, channelization code,
uplink CE resource, downlink CE resource, number of users on HSDPA, and the number
of

users

on

HSUPA,

powerMarginOpen,

the

corresponding

intMarginOpen,

LoadMarginOpen

codeMarginOpen,

parameters

are

ulCeMarginOpen,

dlCeMarginOpen, hsNumMarginOpen, and eNumMarginOpen respectively.


The parameter freClsCeEvaInd determines whether CE resources are evaluated.
If more than one inter-frequency neighboring cell can be opened, these cells are opened

ZTE Confidential Proprietary

Intelligent Carrier Power Off/On Feature Guide

one by one in the following order:


1.

Neighboring cell with Overlap relationship

2.

Neighboring cell with Covers relationship

3.

Neighboring cell with Contained in relationship


For example, in the following figure, cell 1 and cell 2 have an Overlap relationship
with each other, cell 4 has a Covers relationship with cell 3, and cell 3 has a
Contained in relationship with cell 4.

Cell 1/2

Cell 4
Cell 3

For the neighboring cell with an Overlap or Covers relationship, only one carrier
is opened at a time and the carrier with the highest priority is firstly opened
according to the freClosePri. If more than one carrier has the highest priority, the
carrier to be opened is chosen randomly.
For the neighboring cell with a Contained in" relationship, all the carriers are
opened at the same time. For example, in the following figure, cell 1 and cell 2 have
a Contained in relationship with cell 3. When cell 3 is in congestion, cell 1 and cell
2 are opened at the same time.

Cell3
Cell1

Cell2

Note: For algorithm 3, when the working carrier is in congestion state, all the closed
carrier in neighboring cells with Overlap or Covers relationship are opened
immediately.
After a closed cell is opened by any of the above algorithms, a punishment timer
indicated by forbTimAftOpnF is started to avoid ping-pong. Before the expiration of the

ZTE Confidential Proprietary

Intelligent Carrier Power Off/On Feature Guide

timer, the cell will not be closed again even if it meets the carrier closing condition.

3.3

Carrier Power Off Procedure


When the cell is determined to be closed in accordance with a strategy, the RNC informs
the Node B to gradually power down CPICH for a cell via cell reconfiguration procedure.
The carrier power off procedure is shown in Figure 3-2. When the carrier power-off
procedure starts, the CPICH power is decreased step by step. The step size is indicated
by PcpiPwrDnStep. Each time the CPICH power is decreased, a time interval of
PcpiPwrDnTmWin is set. When the time interval is reached, the CPICH power is
decreased again. If the CPICH power is still higher than -10dBm after being decreased
for the maximum of PcpiPwrDnStepTm times, it is configured to -10dBm at the
(PcpiPwrDnStepTm +1) times. Once the CPICH power is down to -10dBm, the Node B
closes the carrier completely. The Node B enters the power saving state.

Figure 3-2

Carrier Power Off Procedure

CPICH Power

Users are handed over to the


adjacent cells gradually
PcpiPwrDnTmWin
PcpiPwrDnStep

-10dBm
t
Carrier power
off starts

Carrier power
off ends

During downgrading the power of a cell, if a cell reconfiguration fails, the RNC stops
closing the cell and the cell remains its current state. When a cell is in power saving state,
if the cell is deleted and then re-established successfully, the cell will operate properly.
After the time when carrier power off is allowed is reached, the RNC determines whether
to close the cell again.

ZTE Confidential Proprietary

10

Intelligent Carrier Power Off/On Feature Guide

3.4

Carrier Power On Procedure


When the cell is determined to be opened in accordance with a strategy, the RNC
configures the transmit power of CPICH to the value indicated by PcpichPwr, via a cell
reconfiguration procedure. If the cell reconfiguration fails to recover the cell from power
saving state, the cell is kept in power saving state until the next check for carrier power
on.

Parameters and Configurations

4.1

Intelligent Carrier Power Off/On Parameters

4.1.1

Intelligent Carrier Power off/on Parameters List


Abbreviated Name

Parameter Name

closeFreFunSwit

Switch of Frequency Intelligently Function

startTimetoClsF

Start Time to Switch Off Frequency Intelligently

endTimetoClsF

End Time to Switch Off Frequency Intelligently

ueNumThreshCls

forbTimAftOpnF

freClsOpnTrigTm

openFreAlg

closeFreAlg

UE Number Threshold Used for Switching Off Frequency


Intelligently
Forbidden Time of Switching Off After Switching On the
Frequency
Trigger Time of Judgment Switching ON/Off Frequency
Intelligently
Switch of Algorithm Used to Switch On the Frequency
Intelligently
Switch of Algorithm Used to Switch Off the Frequency
Intelligently

powerMarginClose

DL Power Margin for Frequency Switch Off Judgement

intMarginClose

UL Interference Margin for Frequency Switch Off Judgement

codeMarginClose

DL Code Margin for Frequency Switch Off Judgement

ulCeMarginClose

UL CE Margin for Frequency Switch Off Judgement

dlCeMarginClose

DL CE Margin for Frequency Switch Off Judgement

ZTE Confidential Proprietary

11

Intelligent Carrier Power Off/On Feature Guide

Abbreviated Name
hsNumMarginClose

eNumMarginClose

Parameter Name
HSDPA User Number Margin for Frequency Switch Off
Judgement
HSUPA User Number Margin for Frequency Switch Off
Judgement

powerMarginOpen

DL Power Margin for Frequency Switch On Judgement

intMarginOpen

UL Interference Margin for Frequency Switch On Judgement

codeMarginOpen

DL Code Margin for Frequency Switch On Judgement

ulCeMarginOpen

UL CE Margin for Frequency Switch On Judgement

dlCeMarginOpen

DL CE Margin for Frequency Switch On Judgement

hsNumMarginOpen

eNumMarginOpen
freClosePri
freClsCeEvaInd

freCloseAllowedInd

PcpiPwrDnStep

PcpiPwrDnTmWin

PcpiPwrDnStepTm

HSDPA User Number Margin for Frequency Switch On


Judgement
HSUPA User Number Margin for Frequency Switch On
Judgement
Priority of Frequency Switch Off
Indication of CE Evaluation for Switching Off Frequency
Intelligently
Indication of Whether the Frequency Switch Off is Allowed or
not
P-CPICH Power Down Step Size Used to Switch Off
Frequency Intelligently
Time Interval between Two Downgrade of P-CPICH Power
Used to Switch Off Frequency Intelligently
Times of Downgrade of P-CPICH Power with Equal Step Used
to Switch off Frequency Intelligently

ShareCover

Share Cover Indication

PcpichPwr

P-CPICH Power

4.1.2

Intelligent Carrier Power Off/On Parameters Configurations

4.1.2.1

Switch of Frequency Intelligently Function

OMC path

ZTE Confidential Proprietary

12

Intelligent Carrier Power Off/On Feature Guide

GUI:

Managed

Element->UMTS

Logical

Function

Configuration->UTRAN

Cell->UTRAN Cell

Parameter configuration
This parameter indicates whether the Intelligent Carrier Power Off/On feature is
supported. When it is set to 1, the Intelligent Carrier Power Off/On feature is
enabled. Otherwise, the feature is disabled.

4.1.2.2

Start Time to Switch Off Frequency Intelligently

OMC path
GUI:

Managed

Element->UMTS

Logical

Function

Configuration->UTRAN

Cell->Extended Info of UTRAN Cell

Parameter configuration
This parameter indicates the start time when intelligent carrier powering off is
allowed. It is displayed as an absolute time, in the format of hour, minute, second.
When the indicated time is reached, if this cell is allowed to close the carrier
intelligently, the conditions for carrier power off will be checked.

4.1.2.3

End Time to Switch Off Frequency Intelligently

OMC path
GUI:

Managed

Element->UMTS

Logical

Function

Configuration->UTRAN

Cell->Extended Info of UTRAN Cell

Parameter configuration
This parameter indicates the end time when intelligent carrier powering off is
allowed. It is displayed as an absolute time, in the format of hour, minute, second.
When the indicated time is reached, this cell is not allowed to close the carrier
intelligently. If the cell is in power saving state and the time-based mode is used, the
cell will be powered on when the end time is reached.

ZTE Confidential Proprietary

13

Intelligent Carrier Power Off/On Feature Guide

4.1.2.4

UE Number Threshold Used for Switching Off Frequency Intelligently

OMC path
GUI:

Managed

Element->UMTS

Logical

Function

Configuration->UTRAN

Cell->Extended Info of UTRAN Cell

Parameter configuration
This parameter indicates the threshold for intelligent carrier power off. If the number
of subscribers in Cell_DCH state in a cell is not greater than the value indicated by
the parameter, the condition of carrier power off is met.

4.1.2.5

Forbidden Time of Switching Off After Switching On the Frequency

OMC path
GUI:

Managed

Element->UMTS

Logical

Function

Configuration->UTRAN

Cell->Extended Info of UTRAN Cell

Parameter configuration
This parameter indicates the forbidden time interval for powering off a cell again
after recovering it from power saving state. The unit is hour and the range is from
0.1 to 24 with a step of 0.1. After a cell recovers from power saving state, the timer
forbTimAftOpnF is started. Before the expiry of the timer, the cell cannot be shut
down again even it fulfills the condition of intelligent carrier power off.

4.1.2.6

Trigger Time of Judgment Switching ON/Off Frequency Intelligently

OMC path
GUI:

Managed

Element->UMTS

Logical

Function

Configuration->UTRAN

Cell->Extended Info of UTRAN Cell

Parameter configuration

ZTE Confidential Proprietary

14

Intelligent Carrier Power Off/On Feature Guide

This parameter indicates the trigger time for a decision of intelligent carrier power
off or on. When the condition is satisfied during the time period specified by
freClsOpnTrigTm, the cell is switched off or on.

4.1.2.7

Switch of Algorithm Used to Switch On the Frequency Intelligently

OMC path
GUI:

Managed

Element->UMTS

Logical

Function

Configuration->UTRAN

Cell->Extended Info of UTRAN Cell

Parameter configuration
This parameter decides the algorithm used to power on a cell in power saving state.
If its value is 0, the time-based algorithm is used. If its value is 1, the
congestion-based algorithm is used. If its value is 2, the algorithm based on time
and congestion is used. If its value is 3, the algorithm based on time or cell load is
used.

4.1.2.8

Switch of Algorithm Used to Switch Off the Frequency Intelligently

OMC path
GUI:

Managed

Element->UMTS

Logical

Function

Configuration->UTRAN

Cell->Extended Info of UTRAN Cell

Parameter configuration
This parameter indicates the algorithm used to power off the carrier intelligently. If
the value is 0, the algorithm based on the number of users in CELL_DCH state is
used to switch off the carrier. If the value is 1, the algorithm based on the cell load is
used to switch off the carrier.

4.1.2.9

DL Power Margin for Frequency Switch Off Judgment

OMC path

ZTE Confidential Proprietary

15

Intelligent Carrier Power Off/On Feature Guide

GUI:

Managed

Element->UMTS

Logical

Function

Configuration->UTRAN

Cell->Extended Info of UTRAN Cell

Parameter configuration
This parameter indicates the DL power margin that must be considered when the
neighboring cell makes a power off decision. A larger value is recommended when
the cell has more than one contained neighboring cell.

4.1.2.10

UL Interference Margin for Frequency Switch Off Judgment

OMC path
GUI:

Managed

Element->UMTS

Logical

Function

Configuration->UTRAN

Cell->Extended Info of UTRAN Cell

Parameter configuration
This parameter indicates the UL interference margin that must be considered when
the neighboring cell makes a power off decision. A larger value is recommended
when the cell has more than one contained neighboring cell.

4.1.2.11

DL Code Margin for Frequency Switch Off Judgment

OMC path
GUI:

Managed

Element->UMTS

Logical

Function

Configuration->UTRAN

Cell->Extended Info of UTRAN Cell

Parameter configuration
This parameter indicates the DL code margin that must be considered when the
neighboring cell makes a power off decision. A larger value is recommended when
the cell has more than one contained neighboring cell.

4.1.2.12

UL CE Margin for Frequency Switch Off Judgment

OMC path

ZTE Confidential Proprietary

16

Intelligent Carrier Power Off/On Feature Guide

GUI:

Managed

Element->UMTS

Logical

Function

Configuration->UTRAN

Cell->Extended Info of UTRAN Cell

Parameter configuration
This parameter indicates the UL CE margin that must be considered when the
neighboring cell makes a power off decision. A larger value is recommended when
the cell has more than one contained neighboring cell.

4.1.2.13

DL CE Margin for Frequency Switch Off Judgment

OMC path
GUI:

Managed

Element->UMTS

Logical

Function

Configuration->UTRAN

Cell->Extended Info of UTRAN Cell

Parameter configuration
This parameter indicates the DL CE margin that must be considered when the
neighboring cell makes a power off decision. A larger value is recommended when
the cell has more than one contained neighboring cell.

4.1.2.14

HSDPA User Number Margin for Frequency Switch Off Judgment

OMC path
GUI:

Managed

Element->UMTS

Logical

Function

Configuration->UTRAN

Cell->Extended Info of UTRAN Cell

Parameter configuration
This parameter indicates the HSDPA user number margin that must be considered
when the neighboring cell makes a power off decision. A larger value is
recommended when the cell has more than one contained neighboring cell.

4.1.2.15

HSUPA User Number Margin for Frequency Switch Off Judgment

OMC path

ZTE Confidential Proprietary

17

Intelligent Carrier Power Off/On Feature Guide

GUI:

Managed

Element->UMTS

Logical

Function

Configuration->UTRAN

Cell->Extended Info of UTRAN Cell

Parameter configuration
This parameter indicates the HSUPA user number margin that must be considered
when the neighboring cell makes a power off decision. A larger value is
recommended when the cell has more than one contained neighboring cell.

4.1.2.16

DL Power Margin for Frequency Switch On Judgment

OMC path
GUI:

Managed

Element->UMTS

Logical

Function

Configuration->UTRAN

Cell->Extended Info of UTRAN Cell

Parameter configuration
This parameter indicates the DL power margin that must be considered when the
neighboring cell makes a power off decision. A larger value is recommended when
the cell has more than one contained neighboring cell.

4.1.2.17

UL Interference Margin for Frequency Switch On Judgment

OMC path
GUI:

Managed

Element->UMTS

Logical

Function

Configuration->UTRAN

Cell->Extended Info of UTRAN Cell

Parameter configuration
This parameter indicates the UL interference margin that must be considered when
the neighboring cell makes a power off decision. A larger value is recommended
when the cell has more than one contained neighboring cell.

4.1.2.18

DL Code Margin for Frequency Switch On Judgment

OMC path

ZTE Confidential Proprietary

18

Intelligent Carrier Power Off/On Feature Guide

GUI:

Managed

Element->UMTS

Logical

Function

Configuration->UTRAN

Cell->Extended Info of UTRAN Cell

Parameter configuration
This parameter indicates the DL code margin that must be considered when the
neighboring cell makes a power on decision. A larger value is recommended when
the cell has more than one contained neighboring cell.

4.1.2.19

UL CE Margin for Frequency Switch On Judgment

OMC path
GUI:

Managed

Element->UMTS

Logical

Function

Configuration->UTRAN

Cell->Extended Info of UTRAN Cell

Parameter configuration
This parameter indicates the UL CE margin that must be considered when the
neighboring cell makes a power on decision. A larger value is recommended when
the cell has more than one contained neighboring cell.

4.1.2.20

DL CE Margin for Frequency Switch On Judgment

OMC path
GUI:

Managed

Element->UMTS

Logical

Function

Configuration->UTRAN

Cell->Extended Info of UTRAN Cell

Parameter configuration
This parameter indicates the DL CE margin that must be considered when the
neighboring cell makes a power on decision. A larger value is recommended when
the cell has more than one contained neighboring cell.

4.1.2.21

HSDPA User Number Margin for Frequency Switch On Judgment

OMC path

ZTE Confidential Proprietary

19

Intelligent Carrier Power Off/On Feature Guide

GUI:

Managed

Element->UMTS

Logical

Function

Configuration->UTRAN

Cell->Extended Info of UTRAN Cell

Parameter configuration
This parameter indicates the HSDPA user number margin that must be considered
when the neighboring cell makes a power on decision. A larger value is
recommended when the cell has more than one contained neighboring cell.

4.1.2.22

HSUPA User Number Margin for Frequency Switch On Judgment

OMC path
GUI:

Managed

Element->UMTS

Logical

Function

Configuration->UTRAN

Cell->Extended Info of UTRAN Cell

Parameter configuration
This parameter indicates the HSUPA user number margin that must be considered
when the neighboring cell makes a power on decision. A larger value is
recommended when the cell has more than one contained neighboring cell.

4.1.2.23

Priority of Frequency Switch Off

OMC path
GUI:

Managed

Element->UMTS

Logical

Function

Configuration->UTRAN

Cell->UTRAN Cell

Parameter configuration
This parameter indicates the priority of the carrier to be powered off intelligently. 0
indicates the highest priority. The lower the priority of a carrier, the more probable
the carrier is to be powered off. It is recommended to set higher priorities for cells
supporting R99+R5+R6 than those supporting R99 only, and set higher priorities for
larger cells than smaller ones.

ZTE Confidential Proprietary

20

Intelligent Carrier Power Off/On Feature Guide

4.1.2.24

Indication of CE Evaluation for Switching Off Frequency Intelligently

OMC path
GUI:

Managed

Element->UMTS

Logical

Function

Configuration->UTRAN

Cell->Extended Info of UTRAN Cell

Parameter configuration
This parameter indicates whether the CE is evaluated during the decision of the cell
load based intelligent carrier power off. If its value is 0, the CE will be evaluated
during the decision. If its value is 1, the CE will not be evaluated during the decision.

4.1.2.25

Indication of Whether the Frequency Switch Off is Allowed or not

OMC path
GUI:

Managed

Element->UMTS

Logical

Function

Configuration->UTRAN

Cell->Extended Info of UTRAN Cell

Parameter configuration
This parameter indicates whether the carrier power off is allowed. The carrier that is
used to provide continuous coverage is not allowed to be closed.

4.1.2.26

P-CPICH Power Down Step Size Used to Switch Off Frequency Intelligently

OMC path
GUI: Managed Element->UMTS Logical Function Configuration->UTRAN Cell->

Extended Info of UTRAN Cell

Parameter configuration
This parameter indicates the size of P-CPICH power down step used to power off
carrier intelligently. In order to avoid call drops of UEs due to fast decrease of
P-CPICH power, this step cannot be set too big.

ZTE Confidential Proprietary

21

Intelligent Carrier Power Off/On Feature Guide

4.1.2.27

Time Interval between Two Downgrade of P-CPICH Power Used to Switch


Off Frequency Intelligently

OMC path
GUI: Managed Element->UMTS Logical Function Configuration->UTRAN Cell->

Extended Info of UTRAN Cell

Parameter configuration
This parameter indicates the time interval between two downgrade of P-CPICH
power used to power off carrier intelligently. This time must be long enough to
complete the cell reconfiguration and hand over UEs to other cells.

4.1.2.28

Times of Downgrade of P-CPICH Power with Equal Step Used to Switch off
Frequency Intelligently

OMC path
GUI: Managed Element->UMTS Logical Function Configuration->UTRAN Cell->

Extended Info of UTRAN Cell

Parameter configuration
This parameter indicates the number of times that P-CPICH power is downgraded
with equal steps for intelligent carrier power off. After the PcpiPwrDnStepTm times
downgrade steps of P-CPICH power, the power is decreased to the lowest value
immediately.

4.1.2.29

Share Cover Indication

OMC path
GUI: Managed Element->UMTS Logical Function Configuration->UTRAN Cell
->Adjacent Relation Configuration->Neighbouring Cell

Parameter configuration

ZTE Confidential Proprietary

22

Intelligent Carrier Power Off/On Feature Guide

This parameter describes the relationship between the current cell and the
neighboring cell. The relationship between the neighboring cell and the current cell
may be Neighbor, Overlap, Covers, or Contained in.

4.1.2.30

P-CPICH Power

OMC path
GUI:

Managed

Element->UMTS

Logical

Function

Configuration->UTRAN

Cell->UTRAN Cell

Parameter configuration
This parameter indicates the P-CPICH power of a cell.

Counters and Alarms

5.1

Counters List
Counter No.

5.2

Description

313046

Ratio of successful CS RAB establishment

313073

Ratio of successful PS RAB establishment

313465

Success Rate of Intra-RNC Inter-Frequency Hard Handover

313249

Ratio of CS Call Drop

313294

Ratio of PS Call Drop

313020

Ratio of successful RRC connection establishment

C310464564

Intelligent Carrier Power Off Duration

C310464565

Number of Intelligent Carrier Power Off

Alarms List
This feature has no related alarm.

ZTE Confidential Proprietary

23

Intelligent Carrier Power Off/On Feature Guide

Glossary
C
CE

Channel Element

CPICH

Common Pilot Channel

D
DCH

Dedicated Channel

H
HSDPA

High Speed Downlink Packet Access

HSUPA

High Speed Uplink Packet Access

R
RAN

Radio Access Network

RNC

Radio Network Controller

ZTE Confidential Proprietary

24

You might also like