Field
Patient
Patient
Patient
Patient
lD
Last name
First name
Ml
Sample date
Sample time start
Sample time end
Channel number
Sample description
Sample type
Site lD
Operator lD
Ordered By
lnterpretation reported
Temperature
lnterpretation reported by
lnterpretation date
Surgeon
Anesthesiologist
Pathologist
Hemotologist
Perfusionist
Cardiologist
Procedure name
Comment
Flag
Flag2
Flas 3
Angle
MA
PMA
G
PG
EPL
cl
cL30
LY3O
String
String
String
String
(S0char)
(5Ochar)
(S0char)
(5Ochar)
Integer (zbyte)
Integer (2byte)
Integer (2byte)
lnteger (2byte)
lnteger (2byte)
Long (4byte)
lnteger (2byte)
Integer (2byte)
Integer (2byte)
Integer (2byte)
Integer (2byte)
Integer (zbyte)
Integer (2byte)
Integer (2byte)
Integer (2byte)
Integer (2byte)
Integer (2byte)
Integer (2byte)
Integer {2byte)
Example
P1A34Z
Anderson
Bob
K
1t11t2001
11:12:O2
11:12:02
baseline
Kaolin
oR-3
ER
Todd
hypercoagulable
37
Bob
1t11t2001
Joe Doe
Rick Smith
MichaelSmith
Tom Doe
Darek Smith
Anna Doe
CABG
patient treated with anticoagulants
Anything 1
Anything 2
Anythins 3
1.0
80.
49.
0.
4800.
1.
15.
47.
0.
49.
100.0
8.
49.0
100.0
0.0
79.5
2.0
1.0
lrun
le
llnteger
ltnteqer
(2byte)
(2bvte)
Test properties
Format
AbnormalFlags
Status
Range
String
String
String
Strino
Value
16.01
96.01
Example
(S0char)
(S0char)
Anything 4
lnterim
(5Ochar)
(5Ochar)
.5 -- 13.7
10.0
o
o
o
r
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
PatientName
Sample
Sample
Sample
Sample
Sample
Site ID
Date
Start/End time
channel number
description
type
Operator ID
Ordered By
Inteqpretation reported
Interpretation reported by
Interpretation date
Temperature
Surgeon
Anesthesiologist
Pathologist
Hernatologist
Perfusionist
Cardiologist
Procedure name
Comment
t
This list is for informational purposes only, and is not meant to be used to develop the actual LIS
interface. Field availabilrty may be subject to TAS version and continued development.
Q: What computer requirements are necessary for using the LIS interface?
A: No specific computer specifications are needed to run the LIS interface. If the computer can
run the TAS and connect to the LIS server, then the LIS interface will work.
Q: What versions include the LIS interface?
A: Version 4.2,3 of the TEG@ Analytical Software and above include the LIS interface.
Q: How do I use the LIS interface?
A: The first thing to do is to contact your LIS provider about interfacing with the TAS.2 your
provider can then contact Haemoscope directly to get the LIS interface specificationso and work
through any issues that may arise. Dependrng on your LIS provider, they may already have an
interface developed for the TAS.
Q; My LIS provider has an interface to the TAS, what is the next step?
A: You will need to run the LIS activation utility and get an activation code from Haemoscop,
and then set some LIS specific settings. Detailed instructions are available &om Haemoscope
upon request, as details may change as new versions are developed.
field.
Q: Our LIS server was unavailable when the sample terminated, how do we get the sample record
to our seryer once it is available again?
A: If a record was not sent to the LIS server at termination for any reason (e.g. computer crash,
network trouble, the LIS was not yetaclrivate$ etc,) it cannot be sent to the LIS interface. There
is not currently an option to manually initiate a sample transfer.
Q: A sample had the wrong patient name when sent to the LIS server. We fixed the problem in
the TAS, how can we change the record on our LIS server?
A: Once the TAS sends a record, you cannot modiff that record on the server by going through
the TAS. You will have to go through your LIS interface, and change the record manually, if
your LIS server supports modifications.
Q: Is the LIS interface two way? Can the TAS retrieve orders or patient names from the LIS
server?
A: No, the TAS can only send data. Except for the acknowledgement that
the LIS server, the TAS cannot receive any data from the LIS server.
2
Please be aware thd your LIS provider may charge a fee for creating an interface to the
not be covered by Haemoscope, and is the customer's responsibility.
will
Activation
To activate the Laboratory Information System (LtS):
1.
Open the LIS activation. lf the file has not been moved, the default location is
C :\Program Files\TEGV4.
LlS
irdivemtl:
wani}o rersqe;
2.
Enter your activation code in the 'Enter activation code:" field. The Activate
button will be active. Once the LIS feature has been activated, the "LlS is active
until:" field will be populated with the new expiration date. (Note: The Lls
activation code is case sensitive.)
3.
4.
You may enter a custom waming message in the "Enter custom expiration
warning message:'field. The Save button will become active.
Click the Save button and "Cunent expiration warning message:'field changes to
the text you entered.
5.
JAS File
The socket configuration and the Ll$ format must be set in the TAS file. open the
TAS.lNl. lf the file has not been moved, the default location is C:\Program Files\TEGV4.
To set the socket configuration, enter the specific lP address after
after LfSPort=.
lf the Lls is being set up with a version 4.2.3 database, set HLTversion equalto 1
(HLTversion=l). lf the LIS was set up with a database earlier than version 4.2.3, set
HlTVersion equal to 0 (HL7Ve rsi on=0).
After making changes to the file, exit the sofrrrare, and restart the softrvare for the
changes to take effect.
Current Amplitude
mm
A30
mm
460
mm
Angle
deg
BIV
Bivalirudin
pg/ml
ccs
mm/min
CCSG
dcs
cl
Coagulation lndex
cL30
o/o
cL60
Yo
CLT
min
Elasticity Constant
d/sc
EPL
disc
Time from R to 20 mm
mtn
mm/min
LG
dcs
LY3O
o/o
LY6O
o/o
MA
Maximum Amplitude
mm
MRL
mm/min
MRLG
dcs
MRTG
mm/min
MRTGG
dcs
PMA
Projected MA
mln
SP
Split Point
min
TEG ACT
sec
TG
mny'min
TGG
dcs
TMA
Time to MA
min
TMRL
mrn
TMRLG
mtn
TMRTG
mtn
TMRTGG
mrn
TPI
/sec
66s = (dyn/cm2lsec)t2
d/sc = dynlcm2
TEG--SdmFl e-Data
Hemostasi s Anal yzer | | I | 2003081-41-30826 | | oRU^R011 1000011 P | 2 . 1 I
lrEG
PrDl ^-\&
555-xl Iooen:ohnnl
| |1555-xl
oBR i 1 i | | | | | 2O02922217s4A9120020222183s19 |
OBX ri srichannel numberl 1l 1l
sri sample description I 1l (abrogated platelets) I
oBXl 2z |i srl
le type I| r1l Kl
srl samp
sample
oexl J3 I| STI
oBXl
oBXl 4 | srl ordered byl 1l
neported I
reporteol| 1-rl| Report
on reported
Interpretatlon
sr i rnterpretiti
oBXl 5 i| STI
oexi ei srirempei'ature | 1l 37 | degrees celsius I
oBxl 7 I srl rnterpretation date | 1l
oBXl 8 | srl surqeon I 1-l Dr. smith I
oBX i 9 i sr ianesthesi ol osi st | 1- I or . rrank
oex i rO I sr I pathol ogi stl I I Bi cF smi th I
oex i rr i sr i uemotol5si st | 1 | Bob smi th I
oBXi 12 i srl perfusioni st I 1l loe smith
osx i tl i sr lcardi ol ogi st | L l pti ke smi th I
oBXi 14i sri procedure namel l-l some procedurel
MSH
oBX | 15
oexl25 srlPGlLl
oBX | 26
oBX I 27
oex I 28
oBX | 29
OBX 30
OBX 31
OBX 3Z
OBX 33
4l
OBX 34
OBX
OBX
OBX
OBX
OBX
35sl
-- 15lrnteriml
srlcrl1l3.2l l-3 -- 3l
sr lA30 | | 64.4
I rnteri
sricL30l 1l 100 .ol%193 -- 1001 rnteriml
srl lv30l 1l0l%10 -- 8 rnteriml
srlEPLlll0l%10
srlAl1l64.6lmml
I mm
1-
srl460l1l lmml
srlcL60lll l%l
srlLY60lll l%l
srlclrl
1l 19.
5 | mi n
mI
rnteriml
srlsplll2.0lminl
377l srlrPr | 1l 33.61/secl3z
388l srlrurlll20.6lminl
36
6l
-- 527
39
sl srl E I LlL79.Old/cm?lL?0 *- 2641
|
eage 1