Professional Documents
Culture Documents
420
Acvatix
VXF31..
Use
For use in heating, ventilating and air conditioning systems as a control valve for
"mixing" or "diverting" functions.
For closed circuits only.
CM1N4420en
2013-09-06
Building Technologies
Type summary
Product number
DN
VXF31.15-2.5
kvs [m / h]
15
VXF31.15-4
Sv
2,5
4
VXF31.24
VXF31.25-6.3
6,3
25
VXF31.25
7,5
VXF31.25-10
> 50
10
VXF31.39
12
VXF31.40-16
16
40
VXF31.40
19
VXF31.40-25
25
VXF31.50
31
50
VXF31.50-40
VXF31.65
40
49
65
VXF31.65-63
VXF31.80
63
78
80
VXF31.80-100
VXF31.90
100
124
100
VXF31.100-160
VXF31.91
160
200
125
VXF31.125-250
VXF31.92
250
300
150
VXF31.150-315
> 100
315
DN = Nominal size
kvs = Nominal flow rate of cold water (530 C) through the fully open valve (H100) by a differential pressure
of 100 kPa (1 bar)
Sv = Rangeability kvs / kvr
= Smallest kv value, at which the flow characteristic tolerances can still be maintained, by a differential
kvr
pressure of 100 kPa (1 bar)
Accessories
Product number
Stock No.
Description
ASZ6.5
ASZ6.5
ASZ6.6
S55845-Z108
Ordering
Example:
Product number
VXF31.50
Stock number
VXF31.50
Designation
3-port seat valve PN10 with flanged connection
Delivery
Quantity
1
2/10
Siemens
Building Technologies
CM1N4420en
2013-09-06
Equipment combinations
Valves
Actuators
SAX..
H100
3)
Mixing Diverting
SKD..
2)
Mixing
1)
SKB..
Diverting
2)
Mixing
SKC..
Diverting
2)
Mixing
Diverting
2)
pmax [kPa]
[mm]
VXF31.15-2.5
VXF31.15-4
VXF31.24
VXF31.25-6.3
VXF31.25
VXF31.25-10
300
VXF31.39
VXF31.40-16
VXF31.40
100
300
100
100
20
300
VXF31.40-25
VXF31.50
VXF31.50-40
VXF31.65
VXF31.65-63
VXF31.80
VXF31.80-100
175
60
275
60
100
40
175
40
VXF31.90
VXF31.100-160
VXF31.91
VXF31.125-250
40
VXF31.92
VXF31.150-315
1)
2)
3)
70
200
70
150
60
100
50
3/10
Siemens
Building Technologies
CM1N4420en
2013-09-06
Actuator overview
Product
Actuator
Operating
Positioning
Spring
number
type
voltage
signal
return
SAX31.00
SAX31.03
SAX81.00
SAX81.03
motoric
SKD82.50
SKD82.51
AC 230 V
DC 010 V
SKB32.50
1)
Yes
SKB82.50
Electro-
SKB82.51
hydraulic
SKB60
Yes
AC 24 V
DC 010 V
SKC32.60
SKC82.60
Electro-
SKC82.61
hydraulic
SKC60
120 s
2800 N
N4566
Yes
Yes
3- position
Yes
AC 24 V
DC 0...10 V
SKC62..
N4564
1)
AC 230 V
SKC32.61
2800 N
Yes
3- position
SKB62..
120 s
30 s
AC 230 V
SKB32.51
N4561
Yes
AC 24 V
SKD62..
1000 N
30 s
120 s
hydraulic
SKD60
N4501
120 s
Yes
3- position
Electro-
800 N
30 s
1)
SKD32.50
SKD32.51
sheet
120 s
AC/DC 24 V
DC 010 V
SKD32.21
Data
force
30 s
3- position
SAX61.03
time
120 s
AC 230 V
Electro-
Positioning Positioning
1)
Yes
Pneumatic actuators
or DC 420 mA or 01000
AB
AB A
B
DN 15 40
closes against pressure
4410Z02
4410Z01
AB A
AB
B
B
DN 50150
closes against pressure
Guided plug which is integrated in the valve stem. The seats are machined in the valve
body. Schematic representation, design variations are possible.
4/10
Siemens
Building Technologies
CM1N4420en
2013-09-06
Sizing
Flow diagram
"Mixing"
DN
pmax
Maximum permissible differential pressure across the valve (mixing: port A-AB, B-AB, diverting:
port AB-A, AB-B), valid for the entire actuating range of the motorized valve
pv100
Differential pressure across the fully open valve and the valves control path A AB, B AB
by a volume flow V100
1 bar 10 mWC
1 m3/h
Valve flow
characteristic
4430D02
100
100 kPa
-A
B
Flow kv / kvs
B
0.8
0.6
A
0.4
AB
B
0.2
0
Through-port
0...30 % linear
30...100 % ngl = 3 as per VDI / VDE 2173
A0
AB
0.2
0.4
0.6
0.8
Stroke H / H100
Bypass
0...100 %:
Mixing:
Diverting:
Port AB =
Port A =
Port B =
linear
Flow from port A and port
B to port AB
Flow from port AB
to port A and port B
constant flow
variable flow
bypass (variable flow)
5/10
Siemens
Building Technologies
CM1N4420en
2013-09-06
4320D03
1
0
-60
-40
-20 -10 0
20
80
100
120
150 160
Notes
Engineering
We recommend installation in the return pipe, as the temperatures in this pipe are lower
for applications in heating systems, which in turn, extends the stem sealing gland's life.
Always use a strainer upstream of the valve to increase the valve's functional safety.
For media below 0 C, use the electric stem heating element to prevent the valve stem
from freezing in the sealing gland. For safety reasons, the stem heating element has
been designed for AC 24 V / 30 W operating voltage.
Mounting
Both valve and actuator can easily be assembled at the mounting location. Neither
special tools nor adjustments are required.
The valve is supplied with Mounting Instructions 74 319 0519 0.
90
90
4362Z01
Orientation
Mixing from
A / B to AB
Commissioning
AB
B
Diverting from
AB to A / B
AB
B
4430Z03
4430Z02
Direction of flow
Commission the valve only if the actuator has been mounted correctly.
Valve stem retracts:
Valve stem extends:
6/10
Siemens
Building Technologies
CM1N4420en
2013-09-06
Maintenance
VXF31.. valves require no maintenance.
Warning
The glands can be exchanged without removing the valve, provided the pipes are
depressurized and cooled off and the stem surface is unharmed.
If the stem is damaged in the gland range, replace the entire stem-plug-unit.
Contact your local office or branch.
Disposal
Before disposal the valve must be dismantled and separated into its various constituent
materials.
Legislation may demand special handling of certain components, or it may be sensible
from an ecological point of view.
Warranty
The technical data given for these applications is valid only in conjunction with the
Siemens actuators as detailed under "Equipment combinations", page 3.
All terms of the warranty will be invalidated by the use of actuators from other
manufacturers.
7/10
Siemens
Building Technologies
CM1N4420en
2013-09-06
Technical data
Functional data
PN class
Working pressure
Flow characteristic
through-port
bypass
Leakage rate
through-port
bypass
Permissible media
PN 10 to ISO 7268
to ISO 7005 within the permissible medium
temperature range according to the diagram on
page 6
030 %
30100 %
0100 %
Medium temperature 2)
Rangeability Sv
Nominal stroke
Industry standards
Materials
Dimensions / Weight
Valve body
DN15 .. DN80
DN100 .. DN150
Stem
Plug
Sealing gland
Gland materials
Refer to "Dimensions", page 9
Flange connections
linear
equal percentage; ngl = 3 to VDI / VDE 2173 1)
linear
00.02 % of kvs value to DIN EN 1349
0.52 % of kvs value
chilled water, low temperature hot water, high
temperature hot water, water with anti-freeze,
brine;
recommendation: water treatment to VDI 2035
-10+150 C
DN 1540:
>50
DN 50150: >100
DN 1580:
20 mm
DN 100150: 40 mm
PED 97/23/EC
as per article 1, section 2.1.4
without CE-marking as per article 3, section 3
(sound engineering practice)
category I, with CE-marking
ISO 14001 (Environment)
ISO 9001 (Quality)
SN 36350 (Environmentally compatible
products)
RL 2002/95/EG (RoHS)
grey cast iron
EN-GJL-200
EN-GJL-250
stainless steel
DN 1540: brass
DN 50150: bronze
Brass, silicon-free
EPDM O rings, silicon-free
to ISO 7005
1)
kvs-values 100, 160, 250, 315 m /h: flow characteristic is over 75 % stroke optimized for maximal flow kv100,
see page 5.
2)
8/10
Siemens
Building Technologies
CM1N4420en
2013-09-06
Dimensions
Dimensions in mm
D2
K
L3
D4
H2
H1
D
4420M01
L2
L1
Product number
VXF31.15-2.5
VXF31.15-4
DN
D2
D4
VXF31.25
L1
L2
L3
H1
H2
kg
SAX..
SKD..
SKB..
SKC..
[kg]
46
65
130
65
65
40,5
137
> 483.5
> 540
> 615
3,3
115
65
85
160
80
80
34
130,5
> 476
> 534
> 609
6,3
150
84
135,5
> 481
> 539
> 614
15
14
95
25
16
40
18
VXF31.24
VXF31.25-6.3
14 (4x)
VXF31.25-10
VXF31.39
VXF31.40-16
VXF31.40
VXF31.40-25
VXF31.50
VXF31.50-40
VXF31.65
VXF31.65-63
VXF31.80
VXF31.80-100
VXF31.90
VXF31.100-160
VXF31.91
VXF31.125-250
VXF31.92
VXF31.150-315
10,4
19 (4x)
50
165
99
185
13,8
20
65
18,5
60
80
22
200
100
24
220
125
156,5
> 502
> 560
> 635
250
24,1
93
209,5
> 666
36,5
104
220,5
> 677
50
120
236,5
> 693
70
26
150
285
23 (8x)
DN = Nominal size
H
= Total actuator height plus minimum distance to the wall or the ceiling for mounting, connection,
operation, maintenance etc.
H1 = Dimension from the pipe centre to install the actuator (upper edge)
H2 = Valve in the "Closed" position means that the stem is fully extended
9/10
Siemens
Building Technologies
CM1N4420en
2013-09-06
Spare parts
Order numbers for spare parts
Set
4310Z02
Sealing gland
4 284 8806 0
4 284 8806 0
4 284 8806 0
4 284 8806 0
4 284 8806 0
4 284 8806 0
4 284 8806 0
4 284 8806 0
4 284 8806 0
4 284 8806 0
4 284 8806 0
4 284 8806 0
4 284 8806 0
4 284 8806 0
4 284 8806 0
4 284 8806 0
4 679 5629 0
4 679 5629 0
4 679 5629 0
4 679 5629 0
4 679 5629 0
4 679 5629 0
74 676 0198 0
74 676 0199 0
74 676 0034 0
74 676 0200 0
74 676 0035 0
74 676 0201 0
74 676 0036 0
74 676 0202 0
74 676 0037 0
74 676 0203 0
74 676 0038 0
74 676 0204 0
74 676 0039 0
74 676 0205 0
74 676 0040 0
74 676 0206 0
74 676 0088 0
74 676 0207 0
74 676 0089 0
74 676 0208 0
74 676 0090 0
74 676 0090 0
Revision numbers
Product number
Valid from
Product number
Valid from
rev. no.
Product number
rev. no.
Valid from
rev. no.
VXF31.15-2.5
..C
VXF31.40
..C
VXF31.90
..C
VXF31.15-4
..C
VXF31.40-25
..C
VXF31.100-160
..C
VXF31.24
..C
VXF31.50
..C
VXF31.91
..C
VXF31.25-6.3
..C
VXF31.50-40
..C
VXF31.125-250
..C
VXF31.25
..C
VXF31.65
..C
VXF31.92
..C
VXF31.25-10
..C
VXF31.65-63
..C
VXF31.150-315
..C
VXF31.39
..C
VXF31.80
..C
VXF31.40-16
..C
VXF31.80-100
..C
10/10
Siemens
Building Technologies
Subject to alteration
CM1N4420en
2013-09-06