Professional Documents
Culture Documents
LAF 800/1000/1250/1600
Conversion kit
104100
Monteringsanvisning
Assembly instruction
SVENSKA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ENGLISH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
-- 2 --
FRSKRAN OM VERENSSTMMELSE
Esab Welding Equipment AB, 695 81 Lax, Sweden, frskrar under eget ansvar att
svetsstrmklla LAH630/LAE800/1000/1250/1600 LAF630/800/1000/1250/1600
frn serienummer 751 r i verensstmmelse med standard EN 60974--1 enligt villkoren i direktiv (73/23/EEG) med tillgg (93/68/EEG) och standard EN 50199 enligt
villkoren i direktiv 89/336/ EEG med tillgg 93/68/ EEG.
-------------------------------------------------------------------------------------------------------------------------------------DECLARATION OF CONFORMITY
Esab Welding Equipment AB, 695 81 Lax, Sweden, gives its unreserved guarantee
that welding power source LAH630/LAE800/1000/1250/1600
LAF630/800/1000/1250/1600 from serial number 751 complies with standard EN
60974--1, in accordance with the requirements of directive (73/23/EEA) and addendum (93/68/EEA) and standard EN 50199 in accordance with the requirements of
directive 89/336/ EEA and addendum 93/68/ EEA .
-------------------------------------------------------------------------------------------------------------------------------------Lax 98--02--16
Paul Karlsson
Managing Director
Esab Welding Equipment AB
695 81 LAX
SWEDEN
SVENSKA
1 SKERHET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 INTRODUKTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5
7
2.1 Allmnt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.2 Tekniska data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7
7
3 INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.1
3.2
3.3
3.4
Allmnt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Monteringsanvisning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Provning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Anslutningar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8
8
12
13
4 DRIFT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
4.1 Allmnt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
15
5 RESERVDELSBESTLLNING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SCHEMA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
KOMPONENTFRTECKNING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RESERVDELSFRTECKNING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
15
28
30
31
TOCs
-- 4 --
SE
1
SKERHET
2.
3.
Arbetsplatsen skall:
S vara lmplig fr ndamlet
S vara dragfri
4.
Personlig skyddsutrustning:
S Anvnd alltid freskriven personlig skyddsutrustning som t ex skyddsglasgon, flamskra
klder, skyddshandskar.
S Se till att inte anvnda lst sittande plagg ssom skrp, armband, ring etc som kan fastna,
eller ge brnnskador.
5.
vrigt
S Kontrollera att anvisade terledare r vl anslutna.
S Ingrepp i elektriska enheter fr endast gras av behrig personal.
S Ndvndig eldslckningsutrustning skall finnas ltt tillgnglig p vl anvisad plats.
S Smrjning och underhll av svetsutrustningen fr ej utfras under drift.
foe1SafS
-- 5 --
SE
VARNING
BGSVETS OCH SKRNING KAN VARA SKADLIG FR ER SJLV OCH ANDRA. VAR DRFR
FRSIKTIG NR NI SVETSAR. FLJ ER ARBETSGIVARES SKERHETSFRESKRIFTER SOM
SKALL VARA BASERADE P TILLVERKARENS VARNINGSTEXT.
ELEKTRISK CHOCK -- Kan dda
S
Installera och jorda svetsutrustningen enligt tillmplig standard.
S
Rr ej strmfrande delar eller elektroder med bara hnder eller med vt skyddsutrustning.
S
Isolera Er sjlv frn jord och arbetsstycke.
S
Ombesrj att Er arbetsstllning r sker.
RK OCH GAS -- Kan vara farlig fr Er hlsa
S
Hll ansiktet borta frn svetsrken.
S
Ventilera och sug ut svetsrk och gas frn Ert och andras arbetsomrde.
LJUSBGEN -- Kan skada gonen och brnna huden
S
Skydda gonen och kroppen. Anvnd lmplig svetshjlm med filterinsats och br skyddsklder.
S
Skydda kringstende med lmpliga skyddsskrmar eller frhngen.
BRANDFARA
S
Gnistor (svetsloppor) kan orsaka brand. Se drfr till att brnnbara freml inte finns i svetsplatsens nrhet.
BULLER -- Starka ljud kan skada hrseln
S
Skydda ronen. Anvnd ronproppar eller andra hrselskydd.
S
Varna personer i nrheten fr riskerna
VID FEL -- Kontakta fackman
LS OCH FRST BRUKSANVISNINGEN FRE INSTALLATION OCH ANVNDNING
SKYDDA ER SJLV OCH ANDRA!
VARNING
Denna produkt r avsedd fr industriell anvndning. I hem-- och kontorsmilj
kan denna produkt orsaka radiostrningar. Det r anvndarens ansvar att vidta
lmpliga tgrder.
foe1SafS
-- 6 --
SE
2
INTRODUKTION
2.1
Allmnt
2.2
Tekniska data
Ndstopp r borttaget
foe1d1sa
-- 7 --
SE
3
INSTALLATION
3.1
Allmnt
VARNING
Roterande delar utgr klmrisk. Iakttag strsta frsiktighet!
3.2
Monteringsanvisning
3.2.1
1. Demontera befintlig kabelstam men behll kablarna 034 och 035 fr matning av
manvertransformatorn.
2. Demontera samtliga elektronikkort med faststtningsdistanser.
3. Demontera manverpanelen.
4. Ta bort bygeln p vilken skringssocklarna r fstade.
5. Ta bort den nedre skringen (K21.2=avskring 42 V AC frn manvertransformatorn K9).
De tv vriga skringarna teranvnds tillsammans med underlggsbrickorna av
gummi, men de monteras p en annan plats i svetsstrmkllan.
6. Ta bort de tv mngpoliga kontaktdonen p den nedre plten och tck hlen
med tv plastpluggar ur monteringssatsen.
foe1i1sa
-- 8 --
SE
7. Demontera skyltarna (en klisterlapp och en fastskruvad skylt, mrkt 42 V) frn
den nedre plten.
8. Demontera plinten p manvertransformatorn.
9. Tck ver kontaktorn och manvertransformatorn innan nya fsthl borras.
10. Borra hl (enl. borrschema) fr faststtning av
S
skringssocklarna (FU1)
elektronikkortet (AP1)
kontaktorn (KM2)
11. Montera ett nytt kretskort (AP1) med lda p plten. Anvnd isoleringsbrickor
och sjlvgngande skruvar fr faststtningen (ingr i monteringssatsen).
12. Anslut avkopplingskondensatorn till jord.
13. Stll in de tv DIP switcharna (SW1 och SW2) p kortet enligt anvisning i
bruksanvisningen fr LAF.
14. Montera den nya uttagsplten.
15. Montera den 28--poliga kontakten (XS4) och isolerkortet p uttagsplten.
16. Koppla in en ny ledningsstam enl. kopplingsschemat.
17. Montera kablar till manverpanelen och anslut sedan manverpanelen till
ledningsstammen.
18. Ta bort (kapa) ledaren 077 mellan kortet K45.3 och strmskenan.
19. Montera tillbaka endast det RC--filter som sitter i den gamla strmkllan.
20. Ta bort det gamla elschemat som sitter p insidan av tckplten.
foe1i1sa
-- 9 --
SE
3.2.2
1. Demontera befintlig kabelstam men lmna kvar kablarna 034 och 035 ur
kabelstammen (anslutning till manvertransformatorn).
2. Klipp av anslutningen till synktransformatorernas ena sida (kablar mrkta 001,
002, 003) som ligger i kabelstammen.
3. Demontera samtliga elektronikkort med faststtningsdistanserna.
4. Demontera manverpanelen.
5. Ta bort skringshllaren K21.2 till hger och ovanfr manvertransformatorn.
Den nedre skringen (K21.2=avskring 42 V AC frn manvertransformatorn
K9) utgr helt och erstts av en automatskring p den nya manverpanelen.
6. Ta bort de tv mngpoliga kontaktdonen p den nedre plten och tck hlen
med tv plastpluggar ur monteringssatsen.
7. Demontera skyltarna (en klisterlapp och en fastskruvad skylt, mrkt 42 V) frn
den nedre plten.
8. Demontera plinten p manvertransformatorn.
9. Demontera shunt (1500 A, 60 mV). OBS! Gller endast fr LAE 1600.
10. Demontera strmrel (K25) som r fst p + skenan, till hger om
manvertransformatorn.
11. Demontera ledningarna (18, 47, 48) som r anslutna till strmrelet.
12. Tck ver kontaktorn och manvertransformatorn innan nya fsthl borras.
13. Borra hl (enl. borrschema) fr faststtning av
S
elektronikkortet (AP1)
kontaktorn (KM2)
foe1i1sa
-- 10 --
SE
14. Montera ett nytt kretskort (AP1) med lda p plten. Anvnd isoleringsbrickor
och sjlvgngande skruvar fr faststtningen (ingr i monteringssatsen).
15. Anslut avkopplingskondensatorn till jord.
16. Stll in de tv DIP switcharna (SW1 och SW2) p kortet enligt anvisning i
bruksanvisningen fr LAF.
17. Montera den nya uttagsplten.
18. Montera den 28--poliga kontakten (XS4) och isolerkortet p mellanplten samt
anslut avkopplingskondensatorn till jord.
19. Koppla in ny ledningsstam enligt kopplingsschemat
20. teranvnd de gamla ledarna 034 och 035 fr anslutning till manvertrans-formatorn (TC1).
21. Anslut ledarna 001, 002 och 003 till de tre synktransformatorernas ena sidor
(TC2).
22. Montera kablar till ndstoppsbrytaren p manverpanelen och anslut sedan
manverpanelen till ledningsstammen.
23. Ta bort (kapa) ledaren 077 mellan kortet K45.3 och strmskenan.
24. Montera tillbaka endast det RC--filter som sitter i den gamla strmkllan.
25. Ta bort det gamla elschemat som sitter p insidan av tckplten.
26. Montera shunt (2000 A, 60 mV). OBS! Gller endast fr LAE 1600.
foe1i1sa
-- 11 --
SE
3.3
Provning
foe1i1sa
-- 12 --
SE
3.4
Anslutningar
3.4.1
Generellt
3.4.2
foe1i1sa
-- 13 --
SE
3.4.3
in
foe1i1sa
-- 14 --
out
SE
4
DRIFT
4.1
Allmnt
Varning:
Har Du lst och frsttt skerhetsinformationen?
Om s ej r fallet fr maskinen inte tas i bruk!
RESERVDELSBESTLLNING
foe1o1sa
-- 15 --
ENGLISH
1 SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
2 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
2.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.2 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
19
19
3 INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
3.1
3.2
3.3
3.4
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Assembly instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
20
20
24
25
4 OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
4.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
27
27
28
30
31
TOCe
-- 16 --
GB
1
SAFETY
Users of ESAB welding equipment have the ultimate responsibility for ensuring that anyone who
works on or near the equipment observes all the relevant safety precautions. Safety precautions
must meet the requirements that apply to this type of welding equipment. The following recommendations should be observed in addition to the standard regulations that apply to the workplace.
All work must be carried out by trained personnel well--acquainted with the operation of the welding
equipment. Incorrect operation of the equipment may lead to hazardous situations which can result
in injury to the operator and damage to the equipment.
1.
2.
3.
4.
5.
General precautions
S Make sure the return cable is connected securely.
S Work on high voltage equipment may only be carried out by a qualified electrician.
S Appropriate fire extinquishing equipment must be clearly marked and close at hand.
S Lubrication and maintenance must not be carried out on the equipment during operation.
foe1SafE
-- 17 --
GB
WARNING
ARC WELDING AND CUTTING CAN BE INJURIOUS TO YOURSELF AND OTHERS. TAKE PRECAUTIONS WHEN WELDING. ASK FOR YOUR EMPLOYERS SAFETY PRACTICES WHICH SHOULD BE
BASED ON MANUFACTURERS HAZARD DATA.
ELECTRIC SHOCK -- Can kill
S
Install and earth the welding unit in accordance with applicable standards.
S
Do not touch live electrical parts or electrodes with bare skin, wet gloves or wet clothing.
S
Insulate yourself from earth and the workpiece.
S
Ensure your working stance is safe.
FUMES AND GASES -- Can be dangerous to health
S
Keep your head out of the fumes.
S
Use ventilation, extraction at the arc, or both, to take fumes and gases away from your breathing zone
and the general area.
ARC RAYS -- Can injure eyes and burn skin.
S
Protect your eyes and body. Use the correct welding screen and filter lens and wear protective
clothing.
S
Protect bystanders with suitable screens or curtains.
FIRE HAZARD
S
Sparks (spatter) can cause fire. Make sure therefore that there are no inflammable materials nearby.
NOISE -- Excessive noise can damage hearing
S
Protect your ears. Use earmuffs or other hearing protection.
S
Warn bystanders of the risk.
MALFUNCTION -- Call for expert assistance in the event of malfunction.
READ AND UNDERSTAND THE INSTRUCTION MANUAL BEFORE INSTALLING OR OPERATING.
PROTECT YOURSELF AND OTHERS!
WARNING
This product is intended for industrial use. In a domestic environment this
product may cause radio interference. It is the users responsibility to take
adequate precautions.
foe1SafE
-- 18 --
GB
2
INTRODUCTION
2.1
General
The welding power sources LAE (adapted to fit control equipment PEG--1) can be
converted to resemble LAF by way of a conversion kit, and by that be adapted to fit
ESABs control box A2--A6 Process Controller (PEH) or Welding Control unit (PEI).
For rational conversion all components necessary for the work are contained in the
conversion kit.
S
Instruction manual for A2--A6 Process Controller (PEH), order no. 0443 745 xxx
Instruction manual for Welding Control Unit (PEI), order no. 0449 375 xxx
2.2
Technical data
The conversion of the power sources results in the following divergencies with
regard to the technical data, compared to previously issued documentation.
S
foe1d1ea
-- 19 --
GB
3
INSTALLATION
3.1
General
WARNING
Rotating parts can cause injury, take great care.
3.2
Assembly instructions
3.2.1
1. Dismount the cable stem, excluding the cables 034 and 035 for the power supply
of the control transformer.
2. Dismount all electronics boards and their fittings.
3. Dismount the control panel.
4. Remove the support with the attached fuse--bases.
5. Remove the lower fuse (K21.2 = fuse for 42 V AC from the control transformer
K9).
The other two fuses are to be re--used together with the rubber spacers, but
fitted elsewhere in the power source.
6. Remove the multi--pole contact devices on the bottom plate and cover the holes
by way of two plastic plugs from the kit.
foe1i1ea
-- 20 --
GB
7. Remove the signs (a sticker and a screwed sign marked 42 V) from the bottom
plate.
8. Dismount the terminal block on the control transformer.
9. Cover the contactor and the control transformer before drilling new mounting
holes.
10. Drill the holes according to the drilling diagram for the attachment of
S
11. Fit a new (AP1) circuit board with box on the plate, using the insulating washers
and self--tapping screws which form part of the conversion kit.
12. Connect the discharge capacitor to earth.
13. Set the two DIP switches (SW1 and SW2) on the board according to the
instructions in the LAF manual.
14. Mount the new terminal plate.
15. Fit the 28--pole contact (XS4) and the discharging board on the terminal plate.
16. Connect a new cable stem according to the connection diagram.
17. Mount the cables for the control panel. Then connect the control panel to the
cable stem.
18. Remove (cut off) the conductor 077 between the board K45.3 and the collector
rail.
19. Only remount the RC filter fitted in the old power source.
20. Remove the old connection diagram on the inside of the cover plate.
foe1i1ea
-- 21 --
GB
3.2.2
1. Dismount the cable stem, excluding the cables 034 and 035 (for the connection
to the control transformer).
2. Cut off the connection to the synchronising transformers (cables marked 001,
002, 003) in the cable stem.
3. Dismount all electronics boards and their fittings.
4. Dismount the control panel.
5. Remove the fuse holder K21.2 fitted above the control transformer to the right.
The lower fuse (K21.2 = fuse for 42 V AC from the control transformer K9) is
replaced by an automatic fuse on the new control panel.
6. Remove the multi--pole contact devices on the bottom plate and cover the holes
by way of two plastic plugs from the kit.
7. Remove the signs (a sticker and a screwed sign marked 42 V) from the bottom
plate.
8. Dismount the terminal block on the control transformer.
9. Dismount the shunt (1500 A, 60 mV). N.B. Only for LAE 1600
10. Remove the current relay (K25) fixed to the +rail to the right of the auxiliary
transformer.
11. Remove the conductors (18, 47, 48) connected to the current relay.
12. Cover the contactor and the control transformer before drilling new mounting
holes.
foe1i1ea
-- 22 --
GB
13. Drill the holes according to the drilling diagram for the attachment of
S
14. Fit a new (AP1) circuit board with box on the plate, using the insulating washers
and self--tapping screws which form part of the conversion kit.
15. Connect the discharge capacitor to earth.
16. Set the two DIP switches (SW1 and SW2) on the board according to the
instructions in the LAF manual.
17. Mount the new terminal plate.
18. Fit the 28--pole contact (XS4) and the discharging board on the terminal plate
and connect the discharge capacitor to earth.
19. Connect a new cable stem according to the connection diagram.
20. Re--use the conductors 034 and 035 for the connection to the control
transformer (TC1).
21. Connect (by soldering) the conductors 001, 002 and 003 in the cable stem to the
three synchronising transformers (TC2).
22. Mount the cables for the control panel. Then connect the control panel to the
cable stem.
23. Remove (cut off) the conductor 077 between the board K45.3 and the collector
rail.
24. Only remount the RC filter fitted in the old power source.
25. Remove the old connection diagram on the inside of the cover plate.
26. Mount the shunt (2000 A, 60 mV). N.B. Only for LAE 1600
foe1i1ea
-- 23 --
GB
3.3
Testing
foe1i1ea
-- 24 --
GB
3.4
Connections
3.4.1
General
3.4.2
Connect the control cable (4) between power source (3) and control box PEH or
PEI (2).
Connect return cable (7) between power source (3) and workpiece (8).
Connect measuring cable (5) between power source (3) and workpiece (8).
foe1i1ea
-- 25 --
GB
3.4.3
Connect control cable (4) between power source (3) and control box
PEH or PEI (2).
Connect return cable (7) between power source (3) and workpiece (8).
Connect welding cable (6) between power source (3) and welding machine (1).
Connect gas hose (9) between reducing valve (10) and gas valve (11) on the
welding machine.
Connect the cooling water hoses (12) between cooling unit (13) and welding
machine (1).
Connect measuring cable (5) between power source (3) and workpiece (8).
in
foe1i1ea
-- 26 --
out
GB
4
OPERATION
4.1
General
Caution:
Have you read and understood the safety information ?
You must not operate the machine beforehand !
General safety regulations for the handling of the equipment can be found on
page 17. Read through before you start using the equipment!
Spare parts are ordered through your nearest ESAB representative, see back cover.
When ordering spare parts, please state machine type and number as well as designation and spare part number as shown in the spare parts list on page 31.
This will simplify dispatch and ensure you get the right part.
foe1o1ea
-- 27 --
Schema Diagram
dia3e11a
-- 28 --
dia3e11a
-- 29 --
LAE/LAF
800/1000
Denomination
LAE/LAF
Remarks
1250/1600
AP1 (K70.1)
Circuit board
AP2
C1
Capacitor
C2
Capacitor
C4
Capacitor
FU1 (K.35)
FU2 (K21.2)
Fuse
Fuse
X
X
X
X
20 A
HL1
42--48 V
HL2
28 V
KM1 (K8)
Contactor
KM2
L1
Contactor
Inductor
X
X
X
X
M1
Fan
QF (K6)
R1
Power resistor
R2
Power resistor
R3
Power resistor
RS1 (K18)
Shunt
ST1
Thermal relay
TC1
Control transformer
TC2
Control transformer
TM1
V1
Transformer
Thyristor
X
X
X
X
V2
Thyristor
V3
Thyristor
V4
Thyristor
XS4
Burndy socket
XT1
Connection block
XT2
Connection block
XT3
Connection block
XT4
Connection block
Z1, Z2
Z3, Z4
Contact protection
Contact protection
X
X
X
X
compdok
-- 30 --
28--pole
Conversion kit
Edition 2003--08--19
Ordering no.
Denomination
LAE 800
LAE 1000
LAE 1250
LAE 1600
Notes
foespare
-- 31 --
Item
no.
Qty
Ordering no.
Denomination
0456795880
LAE 800
Notes
0456433881
0805586131
Contactor
0805586113
Contact block
LAF 800
KM2
0456361882
Cable set
0193260155
Connector
7--pol.
0193260152
Connector
4--pol.
0193260150
Connector
2--pol.
0368544003
28--pol.
0456361883
Cable set
10
11
0193260154
Connector
6--pol.
12
0193260151
Connector
3--pol.
13
0486466880
0456348880
14
AP1.H
XS4
15
0320746001
Main switch
16
0192576004
42--48 V
HL1
17
0192576303
28 V
HL2
18
0567200610
Fuse
16 A 500 V
FU1
19
0193586104
Automatic fuse
20 A
FU2
20
0486368880
Circuit board
AP1
21
0486224880
AP2
22
0193358102
Contactor
23
0319470016
Control transformer
f456795s
QF
KM1
42 V 900 VA
-- 32 --
TC1
Item
no.
Qty
Ordering no.
Denomination
0456795881
LAE 1000
Notes
0456423881
0805586131
Contactor
0805586113
Contact block
LAF 800
KM2
0456861882
Cable set
0193260155
Connector
7--pol.
0193260152
Connector
4--pol.
0193260150
Connector
2--pol.
0368544003
28--pol.
0456361883
Cable set
10
11
0193260154
Connector
6--pol.
12
0193260151
Connector
3--pol.
13
0486466880
0456348881
14
AP1.H
XS4
15
0320746001
Main switch
16
0192576004
42--48 V
HL1
17
0192576303
28 V
HL2
18
0567200610
Fuse
16 A 500 V
FU1
19
0193586104
Automatic fuse
20 A
FU2
20
0486368880
Circuit board
AP1
21
0486224880
AP2
22
0193358102
Contactor
23
0319470016
Control transformer
f456795s
QF
KM1
42 V 900 VA
-- 33 --
TC1
Item
no.
Qty
Ordering no.
Denomination
0456796880
LAE 1250
Notes
0456434881
0805586131
Contactor
0805586113
Contact block
LAF 800
KM2
0456373882
Cable set
0193260155
Connector
7--pol.
0193260152
Connector
4--pol.
0193260150
Connector
2--pol.
0368544003
28--pol.
0456373883
Cable set
10
11
0193260154
Connector
6--pol.
12
0193260151
Connector
3--pol.
13
0486466880
0456322880
14
AP1.H
XS4
15
0320746001
Main switch
16
0192576004
42--48 V
HL1
17
0192576303
28 V
HL2
18
0567200610
Fuse
16 A 500 V
FU1
19
0193586104
Automatic fuse
20 A
FU2
20
0486368880
Circuit board
AP1
21
0486224880
AP2
22
0442849880
Contactor
23
0319470016
Control transformer
24
0319828001
Transformer
f457796s
QF
KM1
42 V 900 VA
TC1
TC2
-- 34 --
Item
no.
Qty
Ordering no.
Denomination
0456796881
LAE 1600
Notes
0456434881
0805586131
Contactor
0805586113
Contact block
LAF 800
KM2
0456373882
Cable set
0193260155
Connector
7--pol.
0193260152
Connector
4--pol.
0193260150
Connector
2--pol.
0368544003
28--pol.
0456373883
Cable set
10
11
0193260154
Connector
6--pol.
12
0193260151
Connector
3--pol.
13
0486466880
0456322881
14
AP1.H
XS4
15
0320746001
Main switch
16
0192576004
42--48 V
HL1
17
0192576303
28 V
HL2
18
0567200610
Fuse
16 A 500 V
FU1
19
0193586104
Automatic fuse
20 A
FU2
20
0486368880
Circuit board
AP1
21
0486224880
AP2
22
0442849880
Contactor
23
0319470016
Control transformer
24
0319828001
Transformer
f457796s
QF
KM1
42 V 900 VA
TC1
TC2
-- 35 --
AUSTRIA
ESAB Ges.m.b.H
Vienna--Liesing
Tel: +43 1 888 25 11
Fax: +43 1 888 25 11 85
BELGIUM
S.A. ESAB N.V.
Brussels
Tel: +32 2 745 11 00
Fax: +32 2 726 80 05
THE CZECH REPUBLIC
ESAB VAMBERK s.r.o.
Prague
Tel: +420 2 819 40 885
Fax: +420 2 819 40 120
DENMARK
Aktieselskabet ESAB
Copenhagen--Valby
Tel: +45 36 30 01 11
Fax: +45 36 30 40 03
FINLAND
ESAB Oy
Helsinki
Tel: +358 9 547 761
Fax: +358 9 547 77 71
FRANCE
ESAB France S.A.
Cergy Pontoise
Tel: +33 1 30 75 55 00
Fax: +33 1 30 75 55 24
GERMANY
ESAB GmbH
Solingen
Tel: +49 212 298 0
Fax: +49 212 298 204
GREAT BRITAIN
ESAB Group (UK) Ltd
Waltham Cross
Tel: +44 1992 76 85 15
Fax: +44 1992 71 58 03
ESAB Automation Ltd
Andover
Tel: +44 1264 33 22 33
Fax: +44 1264 33 20 74
HUNGARY
ESAB Kft
Budapest
Tel: +36 1 20 44 182
Fax: +36 1 20 44 186
ITALY
ESAB Saldatura S.p.A.
Mesero (Mi)
Tel: +39 02 97 96 81
Fax: +39 02 97 28 91 81
THE NETHERLANDS
ESAB Nederland B.V.
Utrecht
Tel: +31 30 248 59 22
Fax: +31 30 248 52 60
NORWAY
AS ESAB
Larvik
Tel: +47 33 12 10 00
Fax: +47 33 11 52 03
POLAND
ESAB Sp.z.o.o
Warszaw
Tel: +48 22 813 99 63
Fax: +48 22 813 98 81
PORTUGAL
ESAB Lda
Lisbon
Tel: +351 1 837 1527
Fax: +351 1 859 1277
SLOVAKIA
ESAB Slovakia s.r.o.
Bratislava
Tel: +421 7 44 88 24 26
Fax: +421 7 44 88 87 41
SPAIN
ESAB Ibrica S.A.
Alcobendas (Madrid)
Tel: +34 91 623 11 00
Fax: +34 91 661 51 83
SWEDEN
ESAB Sverige AB
Gothenburg
Tel: +46 31 50 95 00
Fax: +46 31 50 92 22
ESAB International AB
Gothenburg
Tel: +46 31 50 90 00
Fax: +46 31 50 93 60
SWITZERLAND
ESAB AG
Dietikon
Tel: +41 1 741 25 25
Fax: +41 1 740 30 55
Asia/Pacific
CHINA
Shanghai ESAB A/P
Shanghai
Tel: +86 21 6539 7124
Fax: +86 21 6543 6622
INDIA
ESAB India Ltd
Calcutta
Tel: +91 33 478 45 17
Fax: +91 33 468 18 80
INDONESIA
P.T. Esabindo Pratama
Jakarta
Tel: +62 21 460 01 88
Fax: +62 21 461 29 29
MALAYSIA
ESAB (Malaysia) Snd Bhd
Selangor
Tel: +60 3 703 36 15
Fax: +60 3 703 35 52
SINGAPORE
ESAB Singapore Pte Ltd
Singapore
Tel: +65 861 43 22
Fax: +65 861 31 95
ESAB Asia/Pacific Pte Ltd
Singapore
Tel: +65 861 74 42
Fax: +65 863 08 39
Representative offices
BULGARIA
ESAB Representative Office
Sofia
Tel/Fax: +359 2 974 42 88
EGYPT
ESAB Egypt
Dokki--Cairo
Tel: +20 2 390 96 69
Fax: +20 2 393 32 13
ROMANIA
ESAB Representative Office
Bucharest
Tel/Fax: +40 1 322 36 74
RUSSIA-- CIS
ESAB Representative Office
Moscow
Tel: +7 095 937 98 20
Fax: +7 095 937 95 80
ESAB Representative Office
St Petersburg
Tel: +7 812 325 43 62
Fax: +7 812 325 66 85
Distributors
SOUTH KOREA
ESAB SeAH Corporation
Kyung--Nam
Tel: +82 551 289 81 11
Fax: +82 551 289 88 63
UNITED ARAB EMIRATES
ESAB Middle East
Dubai
Tel: +971 4 338 88 29
Fax: +971 4 338 87 29
ARGENTINA
CONARCO
Buenos Aires
Tel: +54 11 4 753 4039
Fax: +54 11 4 753 6313
BRAZIL
ESAB S.A.
Contagem--MG
Tel: +55 31 3369 4333
Fax: +55 31 3369 4440
CANADA
ESAB Group Canada Inc.
Missisauga, Ontario
Tel: +1 905 670 02 20
Fax: +1 905 670 48 79
MEXICO
ESAB Mexico S.A.
Monterrey
Tel: +52 8 350 5959
Fax: +52 8 350 7554
USA
ESAB Welding & Cutting Products
Florence, SC
Tel: +1 843 669 44 11
Fax: +1 843 664 44 58
ESAB AB
SE-- 695 81 LAX
SWEDEN
Phone +46 584 81 000
www.esab.com
031021