You are on page 1of 6

Control panel CP1

RE 95255
Edition: 12.2013
Replaces: 07.2006

For Electrohydraulic Hitch Control EHC

Contents
Control elements

Analog control panel

CAN control panel

Mating connector

Safety instructions

RE 95255/12.2013, Bosch Rexroth AG

Control panel CP1 |


Control elements

Control elements
Excavation lever (4 positions)
a Transport, lift
b Stop
c Regulate, lower
d Neutral, quick retract
2 Lock (transport)
3 Lowering speed setting
4 Setpoint setting for hitch position
5 Limitation to upper end position
6 Mixture
Innitely variable setting between tractive
force and position control
7 Light: diagnosis
8 Light: lift
9 Light: lower
10 Button for vibration damping
11 Light: vibration damping
1

abcd

10 11 7

9 8 4

Bosch Rexroth AG, RE 95255/12.2013

| Control panel CP1


Analog control panel

Analog control panel


Pin assignment

Technical data

Pin

Functions

Pin

Functions

Ambient temperature range

-20C to +80C

10

10

Supply voltage

9Vto18V

11

Installation position

see oer drawing

11

12

Type of protection

IP66

Supply

13

Symbols

Illuminated

14

Electric connection

Connector, 17-pin

Ground

15

Ground

Weight

1.8kg

16

17

Material number for analog control panel


0538201611

Dimensions
Lock in transport position

90

28.2

20.7
3.2

3.5

4,5
(49)

52.3

33+1

8.6

30020

1690.5

62

1730.5

2240.5
Company Amphenol-Tuchel

16.5

Order no.: CO16 10D017 002 1


14x contact N 02 015 0005 1

14

700.3

150

26.5

150
150

360.2

270

24

26.5

2040.2

63.5

RE 95255/12.2013, Bosch Rexroth AG

Control panel CP1 |


CAN control panel

CAN control panel


Pin assignment

Technical data

Pin

Functions

Ambient temperature range

-20C to +80C

Supply

Supply voltage

9Vto18V

CAN Low

Installation position

see oer drawing

CAN High

Type of protection

IP66

Ground

Symbols

Illuminated

Material number for CAN control panel

Electric connection

Connector, 4-pin

Weight

1.8kg

R917000349

Dimensions
Lock in transport position

52.3
(49)

3.3

3.2

20.7

8.6

28.2

33.4 +0.7
0.4

90

4.5
Z
Manufacturing date

62
1660.5
1730.5

View Z
2:1

1
2240.5
2040.5
172
139.5
135
125
108
102

Foil lettering
see right

2
3
4

63.5
31.5

R4

Neutral, quick retract

Bosch Rexroth AG, RE 95255/12.2013

63.5

8
17.5
20
360.2
700.3

24

8
14

15

15

Regulate, lower (engaged)

15

0
0

26.5

Stop (engaged)

270

16.5

26.5

Transport, lift (engaged)

| Control panel CP1


Mating connector

Mating connector
Wiring harness connector, comprising:
Designation

Material number

Compact connector 1.a

1928403913

Supplier
Robert Bosch GmbH
2

Junior Power Timer contact (pre-galvanized)

929941-3 (0.19mm to 0.38mm ) or


929939-3 (0.50mm2 to 1.00mm2)

Tyco

Single-wire seal

828904 (0.19mm2 to 0.38mm2) or


828905(0.50mm2 to 1.00mm2)

Tyco

Safety instructions
General instructions

Notes on the installation location and position

The proposed circuits do not imply any technical liability

Do not install the control panel CP1 close to parts

for the system on the part of Bosch Rexroth.

that generate considerable heat (e.g. exhaust).

It is not permissible to open the control panel CP1 or to

Radio equipment and mobile telephones must not be

modify or repair the control panel CP1. Modications or

used in the driver's cab without a suitable antenna or

repairs to the wiring could result in dangerous malfunc-

near the control electronics.

tions. Repairs on the control panel CP1 may only be


performed by Bosch Rexroth or by an authorized partner.
System developments, installation and commissioning of
electronic systems for controlling hydraulic drives must
only be carried out by trained and experienced specialists who are suciently familiar with both the components

A suciently large distance to radio systems must be


maintained.
All connectors must be unplugged from the electronics
during electrical welding and painting operations.
Cables/wires must be sealed individually to prevent
water from entering the device.

used and with the complete system.


While commissioning and maintenance the control panel
CP1, the machine may pose unforeseen dangers. Before
commissioning the system, you must therefore ensure
that the vehicle and the hydraulic system are in
a safe condition.
Make sure that nobody is in the machine's danger zone.

Notes on transport and storage


If it is dropped, the control panel CP1 must not be used
any longer as invisible damage could have a negative
impact on reliability.
When cleaning the control panel CP1, do not use any
coarse or abrasive cleaning utensils.

No defective or incorrectly functioning components may


be used. If the components should fail or demonstrate
faulty operation, repairs must be performed immediately.

RE 95255/12.2013, Bosch Rexroth AG

Control panel CP1 |


Safety instructions

Notes on wiring and circuitry

Improper use

The control panel CP1 may only be wired when it is

Any use of the control panel CP1 other than that

de-energized.
Lines to the electronics must not be routed close to
other power-conducting lines in the machine or vehicle.
The wiring harness should be xated mechanically in the

described in chapter "Intended use" is considered to


be improper.
The control panel CP1 is not suitable for use in
safety-related functions.

area in which the control panel CP1 is installed (spacing

Use in explosive areas is not permissible.

< 100mm). The wiring harness should be xated so that

Damages which result from improper use and/or from

in-phase excitation with the control panel CP1 occurs

unauthorized, interference in the component not

(e.g. at the control panel CP1 mounting points).

described in this data sheet render all warranty and

If possible, lines should be routed in the vehicle interior.

liability claims with respect to the manufacturer void.

If the lines are routed outside the vehicle, make sure


that they are securely xed.
Lines must not be kinked or twisted, must not rub
against edges and must not be routed through
sharpedged ducts without protection.
Lines are to be routed with sucient distance from hot

Further information
Further information about the control panel CP1 can be
found at www.boschrexroth.com/mobile-electronics.
The control panel CP1 must be disposed according to
the national regulations of your country.

or moving vehicle parts.


Intended use
The control panel CP1 is only intended for use in applications featuring hitch control with Rexroth controller
and with EHC software installed.
Operation of the control panel CP1 must generally occur
within the operating ranges specied and released in
this data sheet, particularly with regard to voltage,
temperature, vibration, shock and other described
environmental inuences.
Use outside of the specied and released boundary
conditions may result in danger to life and/or cause
damage to components which could result in consequential damage to the mobile working machine.

Bosch Rexroth AG
Mobile Applications
Robert-Bosch-Strae 2
71701 Schwieberdingen, Germany
Tel. +49 711 811 430 80
info.bodas@boschrexroth.de
www.boschrexroth.com/mobile-electronics

Bosch Rexroth AG, RE 95255/12.2013

This document, as well as the data, specications and other information


set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be
reproduced or given to third parties without its consent. The data specied
above only serve to describe the product. No statements concerning a
certain condition or suitability for a certain application can be derived from
our information. The information given does not release the user from the
obligation of own judgment and verication. It must be remembered that our
products are subject to a natural process of wear and aging.

You might also like