Product Guide

BRITISH ENERGY CONTROLS SERVICE TRAINING


MANUFACTURER EFFICIENCY

www.airedale.com
01

Quick reference
Find the right solution for your application
Five product ranges supported by an extensive number of models integrated, they share intelligence and further reduce energy
and exceptional configuration flexibility means that when selecting through combined efficiencies.
an Airedale system, your choice of variants is considerable,
enabling you to precisely match your application. Our breadth of expertise enables us to engineer innovative,
integrated cooling solutions across commercial and public sectors
We apply the latest technology led by smart control logic to ensure - in data centres and other critical environments; industrial process
our products offer you the highest efficiency, resilience and quality. cooling or comfort cooling in retail, leisure and office applications.
First and foremost, they are designed to be stand-alone, but when

Airedale Precision Air Conditioning 6kW 200kW

Your first choice SmartCool™ 16 - 233kW


HFC
AIR WATER D C FREE PAGE 03
DX CW
U O
R410A DX A O EC

Airedale is a British manufacturer INVERTER L L COOL

with nearly 40 years industry EasiCool™ 6 - 64kW


experience. As the UK’s number HFC HFC
AIR WATER
PAGE 03
R410A R407C DX DX CW EC

one provider of chillers, precision


air conditioning and IT cooling AlphaCool™ 8 - 101kW
HFC
AIR FREE PAGE 04
solutions and at the forefront of R407C DX CW COOL

controls software design and


optimisation, we are experts in
integrating our products to reduce
your total cost of ownership. IT Cooling 2kW 60kW

OnRak™ 3 - 35kW
We can help you select the PAGE 05
CW EC
optimum specification tailored
to your application and provide InRak™ 10 - 63kW
the support which will enable you HFC
AIR
PAGE 05
R410A DX CW EC
EC

to manage your cooling system


for best performance, maximum ACE (ECHO) 2 - 20kW per rack SYSTEM SPECIFIC
PAGE 06
longevity and lower operating CW EC

costs.

Global company
Comfort 2kW 77kW
Airedale is a world leader in
the design and manufacture of
StoreMaster™ 50 - 77kW
innovative, high efficiency cooling AIR FREE PAGE 07
HFC
solutions. We manufacture in R410A DX HEAT
PUMP COOL
EC

three continents and export to Cassette 2 - 12kW


customers in over fifty countries CW
PAGE 07

through a network of more than


seventy business partners. *See product pages 3 - 14 inclusive for a reference to which icons represent standard or optional features
02

Chillers 6kW 1300kW Total support,


SCROLL whenever you
DeltaChill™ 110 - 1010kW need it
D/Chill. FreeCool 140 - 1080kW
HFC
AIR FREE
PAGE 09
R410A DX MICRO COOL
EC

Controls PAGE 16
Ultima™ Compact 30 - 450kW
Ult. Compact FreeCool 75 - 450kW
Complete control of your site
HFC
FREE
PAGE 11
R407C
COOL
EC
• Intelligent component optimisation
• Energy analysis and monitoring
Ultima™ Remote Air Cooled &
• ACIS™ building management system
Ultima™ Water Cooled 75 - 450kW PAGE 12
• Chiller sequencing, networking,
HFC
R407C
integration
• Remote monitoring across sites
EcoChill™ 6 - 44kW cooling /
6 - 46kW heating PAGE 10 • Control/component/switchgear
HFC upgrades
R410A HEAT
PUMP

LogiCool™ FreeCool 20 / 40kW


HFC
FREE
EC
PAGE 11
R410A
DIGITAL COOL
CONTROLS

CENTRIFUGAL

TurboChill™ 200 - 1100kW


TurboChill™ FreeCool 200 - 950kW
HFC
FREE
PAGE 09
Service PAGE 18
EC
R134a
COOL

SCREW
24/7 support
• Flexible ChillerGuard™/SafeCool™
OptiChill™ 500 - 1140kW service and maintenance plans;
OptiChill™ FreeCool 750 - 1365kW F Gas compliance
HFC
FREE
EC PAGE 10 • On call engineers for immediate
R134a
COOL
response
• AsNew™ energy upgrades
• Flat pack solutions/unit refurbishment
Genuine spares: Next day delivery
Condensers / CUs / Dry Coolers 3kW 450kW • Genuine components
• Express delivery to UK/overseas
BluCube™ 10 - 48kW locations
HFC EC
PAGE 13 • Manufacturer’s warranty
R410A HEAT
PUMP DIGITAL

• Rapid parts identification and


Air Cooled Condensers technical support
& Dry Coolers
CR 12 - 174kW (R410A)
C/CS 11 - 105kW (R407C)
DR 10 - 100kW
HFC HFC PAGE 13
R410A R407C EC
SERVICE

Ultima™ Compact Condensing


Unit 30 - 450kW THR PAGE 14
HFC EC
R407C

Training PAGE 18
Condensing Units 3 - 80kW THR
HFC
R407C HEAT
PAGE 14 Develop your skills
PUMP

• AC&R Modules 1, 2 and 3


• Regulatory industry courses including
- F Gas J11
- JO4 & JO5 Pipework & Brazing
PRODUCT KEY* - Essential & Refrigeration Electrics
More details of courses on page 18
AIR WATER Book online:
HFC HFC HFC
R410A R134a R407C DX DX CW HEAT
PUMP
www.airedale.com/training-events

HFC R410A HFC R134a HFC R407C AIR COOLED WATER COOLED CHILLED WATER HEAT PUMP UPFLOW DOWNFLOW UPFLOW/
DOWNFLOW

D C FREE
U O EC
A O TRAINING
EC INVERTER DIGITAL MICRO L L COOL
SCROLL SCREW CENTRIFUGAL EC INVERTER INVERTER DIGITAL MICROCHANNEL DUAL COOL FREE-COOLING EC FAN
COMPRESSOR COMPRESSOR COMPRESSOR COMPRESSOR COMPRESSOR COMPRESSOR COIL
03

Precision air conditioning

SmartCool™ 16 - 233kW EasiCool™ 6 - 64kW

46% energy saving in free-cooling 50 - 100% variable capacity control


KEY SPECIFICATIONS:

KEY SPECIFICATIONS:

HFC HFC
R410A dual cool variant R410A with suction throttle valve option
Up to 88% saving in power input Up to 70% more efficiency with EC fans
AIR AIR
with hot gas re-heat option optional upgrade on all indoor and outdoor units
DX DX
+ DX air (16 – 137 kW); water cooled (60 – 137kW); chilled + 76 DX (38 air cooled and 38 water cooled) and 34 chilled
WATER water (16 – 233kW) and free-cooling models; single and WATER water models, in 6 case sizes
DX dual circuits DX + Tandem scroll compressors for reduced sound and part
+ Up to 6 stages of tandem scroll compressor DX cooling load efficiencies (models 20 - 64kW)
+ Direct drive, speed controllable AC fans + AV mounted, direct drive, speed controllable EC fan
CW OPTIONS INCLUDE
CW technology (models 6 - 27kW)
+ Automatic adjustment of air volume: Faced with system + Variable humidification for precisely conditioned air
resistance, fan speed modulates to give constant air + Full 360° service and maintenance access
volume
OPTIONS INCLUDE
+ High efficiency de-humidification + Hot gas re-heat efficiently re-heats cool air during
+ Electronic expansion valves for up to 30% increase in dehumidification
system efficiency + Electric heating can be upgraded with thyristor control
+ Thyristor-controlled electric heating for precise control + Direct drive backward curved EC fan upgrade for all
OPTIONS

D C
U O + Suction throttle valve technology for variable capacity HFC indoor and outdoor units
A O R407C
L L + Dual power supply for redundancy and flexibility
FREE + Optimised for EC fan
EC
COOL
OPTIONS

INVERTER

EC
04

Data centres
Computer rooms
Base stations
Clean rooms
Laboratories

“ Continued operation of our clients’ IT infrastructure and


ensuring availability of their data is paramount. Airedale
provides us with a fully integrated cooling solution designed
for maximum efficiency and critical redundancy. Airedale’s
latest chilled water and DX cooling technologies enable us to


achieve our PUE target of less than 1.3.
Rob Garbutt, CEO, LDeX
AlphaCool™ 8 - 101kW

Up to 30% increase in system efficiency


KEY SPECIFICATIONS:

HFC
R407C with optional electronic expansion valves

AIR + DX, chilled water and glycol free-cooling systems


DX + 102 models in 5 case sizes
+ AV mounted fans
+ Direct drive, speed controllable fans (models 9 - 19kW)
CW + Reduced sound and vibration emission levels
+ Single, dual and triple circuit systems for stage cooling
control
+ Variable humidification for precisely conditioned air
+ G4 as standard filter; optional G3/F6 for higher efficiency
filtration

FREE

COOL

Total support from Airedale

CONTROLS SERVICE TRAINING

SafeCool™ Service Plan


Maximising your system’s efficiency 24/7
www.airedale.com
05

IT Cooling

OnRak™ 3 - 35kW InRak™ 10 - 63kW

88% saving in power input EER up to 94.86


KEY SPECIFICATIONS:

KEY SPECIFICATIONS:

HFC
CW an OnRak™ with EC fan and an EER of 144.7 R410A n + 1, CW
EER 114.45 (n); 183.02 (n+1) 66% energy saving p.a.
AIR
n+1 fan configuration for increased efficiency and resilience with EC fan
EC
Over 50% saving in energy DX 25 - 100% fully modulated cooling
when integrated with a free-cooling chiller for substantial energy savings when operating at part load

+ Efficient rear door heat exchanger with 200mm footprint CW + Efficient in-row cooling solution for medium to high
+ Two configurations: (n) 35kW cooling (100% air volume); density applications
optional (n+1) 30kW cooling (75% air volume) + Positioned next to a single rack or within a row of racks
+ Designed to fit 42 - 47U racks EC + Directs cool air horizontally to the front of the racks,
+ Supplied with integrated rack or adapted to fit a maintaining even cooling
customer specific rack, with simple connections EC + n+1 fan configuration for increased efficiency and
+ Pressure differential management - maintaining pressure resilience
in the rear of the rack within the server design envelope + Aisle differential pressure control for resilience
+ Flexible water connections maintain cooling when door + Hot swappable fan management
is open + Over 50% saving in energy when integrated with a free-
+ Hot swappable fan management cooling chiller
+ Water detection and automatic isolation + Up to 70% more efficiency with EC fans
+ Self-regulating constant flow control eases + Compact design for increased cooling per square metre
commissioning
OPTIONS INCLUDE
+ High efficiency aluminium fin heat exchanger with + Dual power supply/static transfer switch
integral coil guard
06

Airedale ECHO CRAC unit Airedale ECHO


20 - 200kW free-cooling chiller
20 - 1300kW

Active Cabinet
Exhaust (ACE) Airedale ECHO Monitoring
2 - 20kW & Control System (EMCS)

“ Our HPC facility is growing and without the use of the


OnRak™ rear door heat exchangers it would not be possible
to go to such high densities. The OnRak™ has saved us
space in an already densely packed environment. It has also
given us the flexibility to fit rear door heat exchangers to


legacy or new cabinets from any manufacturer.
Dr Jon Summers, Senior Lecturer, The University of Leeds
ECHO High efficiency IT cooling system

67% energy saving


KEY SPECIFICATIONS:

CW compared with a conventional downflow system


50% less air volume, using less power
by varying the air volume
EC
Up to 95% free-cooling per annum
+ Ensures the correct air quantity, temperature and
pressure is fed to the server inlet
+ Variable rack load densities to a maximum of 20kW
per rack
+ No chilled water/refrigerant connections at the rack or
in the IT space
+ Control is led from rack level, rescheduling the
Airedale ECHO CRAC and free-cooling chiller to
optimise performance
Data centres
+ n + 1 fans for complete confidence
High density areas
+ Pressure differential management so ACE fans mirror
the server fans
ISP facilities
+ Eliminates hot spots
Computer rooms
+ With no hot/cold aisle configuration, the technical
space available for IT equipment is increased
Total support from Airedale

CONTROLS SERVICE TRAINING

SafeCool™ Service Plan


EER: Energy Efficiency Ratio Maximising your system’s efficiency 24/7
www.airedale.com
07

Comfort

StoreMaster™ 50 - 77kW Cassette 2 - 12kW

Up to 70% more efficiency Smaller models fit the space


KEY SPECIFICATIONS:

KEY SPECIFICATIONS:

HFC
R410A with EC fans CW of a standard ceiling tile
0 - 100% free-cooling as standard measuring 600mm2
AIR
using full design air volume
DX + 11 models for flexibility in heating,
+ ETL listed* (models featuring an inverter-driven cooling and air flow
condenser fan and return air fan) + Available in 2 pipe and 4 pipe
HEAT + Cooling and heat pump variants configurations
PUMP
+ 57 - 75kW heating capacity with reverse cycle (dual + Efficient AC backward curved fan
circuit heat pump variant only) technology
+ Packaged or split modules (evaporator / condenser) + Low sound
+ Tandem scroll compressors on a single circuit for + Neat, compact design
FREE improved efficiency at part load (cooling-only version) + Smart, unobtrusive
COOL + Fresh air connection
OPTIONS INCLUDE
EC + Heating based on a LPHW heating
coil
+ Electric heating (two pipe variant
only)

*ETL: Energy Technology List www.eca.gov.uk


08

“ Our priority at the Harrogate Hydro leisure facility is to


provide the comfortable environment which our customers
have come to expect. A major concern was to find a reliable,
appropriate air conditioning system which would keep a cool,
constant temperature within the building. Airedale’s chilled


water chiller and cassette solution is delivering that.
Andy McCulloch, Group Engineer, Harrogate Borough Council

Offices
Shopping malls
Retail outlets
Leisure environments
Commercial applications
Distribution centres

Total support from Airedale

CONTROLS SERVICE TRAINING

SafeCool™ Service Plan


Maximising your system’s efficiency 24/7
www.airedale.com
09

Chillers
Scroll Centrifugal

DeltaChill™ (DCC) 110 - 1010kW TurboChill™ (TCC) 200 - 1100kW


DeltaChill™ FreeCool (DCF) 140 - 1080kW TurboChill™ FreeCool (TCF) 200 - 950kW

ESEER up to 5.03 ESEER up to 6.16


KEY SPECIFICATIONS:

KEY SPECIFICATIONS:

HFC HFC
R410A with EC fan option R134a with TCC, due to excellent part load efficiencies
Class A EER up to 3.60 Free-cooling for up to 95% per annum
AIR
with TCF
DX + ETL listed* (DCC and DCF ) 450kW)
10.0 COP at part load
+ 282 models: 151 models (DCC) and 131 models (DCF)
FREE
+ Single, dual or triple independent refrigeration circuits, + ETL listed
allowing 2 - 9 stages of cooling COOL + Up to two compressors across a single circuit for
+ Up to 95% free-cooling with DCF reduced energy consumption at part load (TCC & TCF);
+ Up to 38% more cooling/m2 than Airedale’s previous EC dual circuit models for resilience (TCC, TCF)
MICRO generation free-cooling chillers + Oil-free compressor enhances heat exchange
+ Low sound ranges: Quiet and Extra Quiet + 25 - 100% variable speed control for exact capacity
FREE
+ E-coated micro-channel coils reduce life cycle costs and match
COOL footprint (all DCF models and DCC 450 - 960kW) MICRO
+ In-built compressor low current start (2A)
+ Modular, efficient ‘V’ frame fan coil module + Low sound: Quiet or Extra Quiet
OPTIONS

EC + Direct Effect Life Cycle (DELC) CO2 equivalent emissions + Interactive head pressure setpoint management
of )1000 kgCO2e/kW cooling capacity enable the
+ Flooded evaporator for optimum system efficiency
DCC and DCF to contribute to a building achieving 1
BREEAM point + Large surface area condenser coils
+ Economiser circuit provides increased cooling and
OPTIONS INCLUDE
enhances EER in full and part load operation
+ Inverter-controlled pump ensures constant water flow
(TCC & TCF)
+ Automatic refrigerant pump down combined with leak
detection enable the DCC and DCF to contribute to a
building achieving 1 BREEAM point

*ETL: Energy Technology List www.eca.gov.uk


10

Screw Scroll

OptiChill™ (OPC) 500 - 1140kW


OptiChill™ FreeCool (OFC) 750 - 1365kW EcoChill™ 6 - 44kW cooling / 6 - 46kW heating

ESEER up to 4.21 Heat pump or cooling only


KEY SPECIFICATIONS:

KEY SPECIFICATIONS:

HFC HFC
R134a with OPC, for optimum operating efficiency R410A ESEER up to 4.25
Up to 30% increase in system efficiency due to excellent part load efficiencies
with electronic expansion valves (option) Class A EER up to 3.38
HEAT
PUMP
+ ETL listed* (all OPC models) + 6 - 44kW nominal cooling capacity
FREE
+ 52 models (OPC) and over 200 models (OFC) + 6 - 46kW nominal heating capacity
COOL + Quiet and Extra Quiet ranges + 11 models available
+ Dual independent refrigeration circuits for resilience + Quiet axial fans with fan speed control
OPTIONS

EC + Up to 95% free-cooling with OFC + Compact configuration: greater cooling per m2


+ 12.5°C increase in operational evaporating + Condensate drip tray (heat pump units only)
temperature range allowing supply water
OPTIONS INCLUDE
temperatures to be increased, thus raising the free-
cooling threshold and giving enhanced compressor + Heat pump ideal for comfort applications
efficiency and reduced power input (OFC) + Full and flexible hydronics package available
+ Intelligent head pressure control, optimises + Soft start to reduce transient starting peaks
performance (OFC only)
+ Latest fan technology reduces sound and power input
+ 8 stages of cooling for more precise capacity match
+ Large surface area condensing coils
+ High efficiency shell and tube evaporator Total support from Airedale

CONTROLS SERVICE TRAINING

EER: Energy Efficiency Ratio


ChillerGuard™ Service Plan
ESEER: European Seasonal Energy Efficiency Ratio Maximising your system’s efficiency 24/7
COP: Coefficient of performance www.airedale.com
11

Chillers
Scroll Scroll

Ultima™ Compact (UCC) 30 - 450kW


LogiCool™ FreeCool 20kW / 40kW Ultima™ Compact FreeCool 75 - 450kW

Up to 95% free-cooling Up to 62% free-cooling


KEY SPECIFICATIONS:

KEY SPECIFICATIONS:

HFC HFC
R410A per annum R407C of UCFC DX performance
Over 50% saving in energy + ETL listed*
compared with a conventional chiller
+ 75 models (UCC) and 45 models (UCFC)
DIGITAL Compact footprint from 1.5m2
+ Standard, Quiet and Super Quiet variants
minimises space claim
FREE FREE + Single and dual circuit models (UCC 30 - 80kW); dual
circuit on UCFC and all larger UCC models
COOL + ETL listed* COOL
+ Modulating head pressure control
+ Variable capacity control for exact capacity match
OPTIONS

OPTIONS

EC + Exceptional part load efficiencies EC OPTIONS INCLUDE


+ Electronic expansion valves for up to 30% increase in
+ Direct-drive axial fan
system efficiency
+ Efficient plate evaporator with EEV refrigerant controls
+ Large surface area condensing coils maximise energy
efficiency
+ Connects to direct rack cooling systems (individual or
multi-rack)
+ Expandable, flexible solution as load increases
+ Modular design plus condensing coils and water
connections at the rear, allow close side-by-side
positioning
+ Reduced minimum system water volumes

*ETL: Energy Technology List www.eca.gov.uk


12

Scroll

“ Our target is to reduce building energy costs by 7% annually


which we have achieved over the past two years. Airedale’s
free-cooling chillers are already contributing to 3% of this
annual saving. We make the equipment work through a
complete and positive partnership with Airedale, from design


through to service and maintenance.
Ultima™ Remote Air Cooled** Paul Lovegrove, General Affairs Assistant Manager, Epson

Ultima™ Water Cooled 75 - 450kW

Up to 30% increase in system efficiency Data centres


KEY SPECIFICATIONS:

HFC
R407C with optional electronic expansion valves Clean rooms
Offices
+ ETL listed*
Retail outlets
+ 75 - 450kW nominal cooling capacities
Leisure environments
+ 45 models
Process cooling
+ Standard, Quiet and Extra Quiet variants
+ Dual independent refrigeration circuits
+ Compact unit footprint
+ High efficiency plate heat exchangers

**Pictured

Total support from Airedale

CONTROLS SERVICE TRAINING

ChillerGuard™ Service Plan


EER: Energy Efficiency Ratio Maximising your system’s efficiency 24/7
ESEER: European Seasonal Energy Efficiency Ratio www.airedale.com
13

Condensers
Condensing Units

Air Cooled Condensers


BluCube™ & Dry Coolers
Heat pump (10 - 48kW) / Cooling only (13 - 40kW) CR 12 - 174kW (R410A), C/CS 11 - 105kW (R407C), DR 10 - 100kW

Up to 30% increase in system efficiency Up to 70% more efficiency with EC fans


KEY SPECIFICATIONS:

KEY SPECIFICATIONS:

HFC HFC
R410A with remote electronic expansion valve (REEV); standard with R410A option on R410A models
digital scroll compressor, an option on fixed capacity models
44% more cooling per m2 HFC + CR: 8 models (R410A)
R407C + C/CS: 10 models ( R407C)
HEAT
PUMP average compared with a conventional CU system
+ Dry coolers: 14 models
OPTIONS

+ ETL listed* (cooling only models) EC + Small footprint, low profile for minimum space claim
+ Integrates with industry standard air handling units + Floor-mounted
+ 2 case sizes; 24 models + Horizontal or vertical unit design for flexibility
OPTIONS

+ Operating envelope -20°C to +25°C in heating or -20°C + Coil guards


DIGITAL
to +48°C in cooling + Low sound levels
+ Two pipe system reducing installation time and cost + Discharge and liquid shut-off valves
EC
+ Digital scroll compressor for 16 - 100% variable capacity
(model dependent)
+ Modulating head pressure control for increased
efficiency
+ Short-cased axial fan to overcome external static
pressure when ductwork is required
+ Fits into a standard lift facilitating easy installation
OPTIONS INCLUDE
+ Compressor attenuation reducing compressor sound by
up to 12dBA
+ Integrated condensate drip tray (heat pump models)

*ETL: Energy Technology List www.eca.gov.uk


14

Ultima™ Compact
Condensing Units (CU) Condensing Unit
3 - 80kW 30 - 450kW THR

CU1 - CUS4 Up to 30% increase in system efficiency


KEY SPECIFICATIONS:

KEY SPECIFICATIONS:

HFC HFC
R407C 3 - 13kW total heat rejection R407C with remote electronic expansion valve (REEV) option
+ 8 models: Cooling only and heat pump variants
+ Reciprocating compressor + 75 models for configuration flexibility
HEAT
PUMP
+ Wall mountable, freeing up floor space + Standard, Quiet and Super Quiet variants
+ Small footprint with slimline design + Dual independent refrigeration circuit for resilience
OPTIONS

+ Head pressure control optimising efficiency and reduced operating costs (single circuit option on
EC
30 - 80kW)

CUS5 - 12
KEY SPECIFICATIONS:

HFC
R407C 14 - 35kW total heat rejection
+ 5 models: Cooling only and heat pump variants
Data centres
+ Floor mounted for external location
Clean rooms
HEAT + Low profile
PUMP
Offices
Retail outlets
Leisure environments

CUS15 - 30D
KEY SPECIFICATIONS:

HFC
R407C 40 - 80kW total heat rejection
+ 7 models: Cooling only
Total support from Airedale
+ Scroll compressors for reduced sound, higher
efficiency and lower electrical starting currents
+ Floor-mounted for external locations CONTROLS SERVICE TRAINING
+ Small footprint
SafeCool™ Service Plan
Maximising your system’s efficiency 24/7
THR: Total Heat of Rejection www.airedale.com
15

Performance tested
And proven

“ Airedale gives us support


Quality is assured by our on-site world class
testing and production facilities and the
application of the latest manufacturing and reassurance throughout
techniques and continuous improvement. A factor influencing selection of Airedale
was its transparency and facility to
Airedale’s dedicated test facility is the only witness test. We prefer working with a UK
purpose-built one of its kind in the UK. Here all manufacturer who is carrying out product
our product lines are performance tested for a development work and can give us support


global market. Accurate test data is produced and reassurance throughout.
anywhere from -5°C to +55°C in controlled
ambient environments. The climate test Steve Vandyke
Head of Technical Services, National Gallery
chambers include a hemi-anechoic chamber
for accurate measurement of sound data.

Load conditions are simulated from early


development of a new product through to
final assembly. Customers can witness-
test products to verify duty and energy
performance to ensure they will meet
operational requirements.

“ We have a positive,
responsible partnership “ Energy efficiency was
the crucial factor “ EDF Energy is already
seeing a PUE of 1.2 “ Iceland Frozen Foods (IFF)
has realised savings of
with Airedale in which we £1.5m to date
Airedale proved that its free- I believe we are the first
share knowledge
cooling chiller can save energy company in the world to install The typical payback is between
and is the right system for us. Airedale’s advanced technology, six and nine months per store,
It is only through Airedale’s
Anything that improves payback the TurboChill™ FreeCool making Airedale Controls’
continued site involvement that
is of interest to the Society. We chiller. When the data centre is solution extremely attractive
we can fine tune the system to
have also had good service operating in free-cooling mode, operationally and financially.
such an extent. We don’t mind


from other Airedale products. the PUE has been measured Its flexibility has enabled IFF
spending capital expenditure to
at 1.2 and we expect that to to carry out a progressive
recoup such significant energy
Steven Ward reduce further as we install more implementation strategy,


savings as these. Premises Engineer,


Yorkshire Building Society
equipment. integrating existing Airedale
Paul Lovegrove equipment, as well as new and
Bob Finn


General Affairs Assistant Manager, old systems from other OEMs.
Epson Programme Manager, EDF Energy

Graham Ireland
Building Services Manager, IFF
16

Intelligent controls
Seamlessly managing your system
The control centre of each of our cooling systems is a
sophisticated electronic microprocessor specially developed by
Taking building
Airedale. The intelligent microprocessor uses sensors to send
and receive messages to and from active components so they management to
another level
respond and interact. By integrating and sequencing components,
the controller manages and optimises the system’s performance,
availability and power draw, giving the operator complete system
control. ACIS™ building management system developed
by Airedale, enables you to manage smart
Fully-programmable via the control panel’s user-friendly display, the cooling and other building services, from any
microprocessor can be linked with all standard BMS protocols to: manufacturer, in a single, integrated system
across multiple sites and communication
Trigger alarm Send alarm/service protocols. ACIS™ sits at the front end of a
messages messages via email or building system, putting you in control of
SMS using an interface reducing operating costs.

Operate time ˚C Allow adjustment of With the click of a button on a PC, tablet or
scheduling temperature setpoints phone, intelligent information can be pulled back
automatically for remote 24/7 monitoring and
maintenance; enhanced system operation and
improved decision-making.

Integration protocols

Generator/ Energy
UPS/Server Manager

Sequencer

Building lighting
17

Tailor-made for you


Working in partnership
Customer focus is central to
our core principles at Airedale.
We will work closely with you
to adapt our flexible systems
to fit exactly to your specific
cooling needs and energy
requirements. Communication
is key to understanding your
requirements so we ensure you
are kept informed and actively
involved every step of the way. London Data Exchange National Gallery
£5m colocation facility > 6 x TurboChill™ chillers supplying chilled water
Our ability to handle complex > 4 x 280kW DeltaChill™ FreeCool chillers to a primary circuit
projects worldwide and meet supplying chiiled water to 10 x chilled water The TurboChill™ replace existing R22 chillers with
the toughest of deadlines 110kW SmartCool™ precision air conditioning a bespoke, sequenced chiller solution, integrating
ensures we always deliver units, each providing under floor cold aisle new technologies; modern refrigerant and design
quality assured products delivery at a constant 22°C to contained aisles criteria and increased control
and service, no matter how Benefits: Benefits:
challenging the task. • PUE less than 1.3 • ESEER 5.87
• Free-cooling for up to 95% of the year • £16,000 energy saving in first year
• 13% less space claim • Enhanced reliability and less maintenance
• N + 1 redundancy • Matches existing rooftop space and
connections

The University of Leeds Victoria & Albert Museum


HPC facility Computer room
> 3 x OnRak™ rear door heat exchangers each > 4 x 40kW EasiCool™ downflow precision air
providing 28kW high density cooling conditioning units
> 2 x 240kW Ultima™ Compact FreeCool chillers Each EasiCool™ provides under-floor cold
Benefits: aisle delivery of 120kW cooling and reliable
• OnRak™ is ideal for high density HPC facilities environmental control of the data centre space.
• Slots into existing cooling loop; expandable Benefits:
• Eliminated need to build a new computer room • N+1 redundancy
• Extremely compact 200mm profile • Scalable and future proof
• Free-cooling for up to 95% of the year
• 35% savings in energy
18

Total support
Whenever you need it
Sharing our expertise
By investing in an Airedale cooling system, you can benefit from our advice, expertise and support all along the way.
From design and selection through to commissioning and beyond, we make sure your cooling system reduces your
total cost of ownership and gives you maximum system availability and longevity.

1 2 3 4
Talk directly with Have complete 24/7 support; Develop
an experienced control of your maintenance and your skills
engineer site spares

Customers with critical Knowing you have Learn more about


+44 (0)113 239 1000 sites can benefit from immediate help on your cooling system
our remote monitoring hand day or night, is by attending an air
Find out how we design facility. After-sales services reassuring particularly if you are conditioning and refrigeration
our systems to reduce your include chiller sequencing, responsible for keeping critical course in our purpose-built
whole life costs. Our highly network setup and integration systems operational 24/7. training school. Train on high-
experienced engineers are as well as a live demonstration Realise the full potential of your tech cooling systems and
adept at tailoring our systems to and training centre at our head- system; improve its longevity fully operational rigs in our
suit your solution. office. and efficiency and be F Gas dedicated workshops. Industry-
compliant. Avoid downtime with recognised courses also
our fast, efficient spares service. available.

Air conditioning & refrigeration courses Regulatory industry courses


+ Module 1 - Basic refrigeration & air conditioning + CITB F-Gas J11 Category 1, 2, 3 & 4
+ Module 2 - Air conditioning installation, commissioning & + CITB JO4 & JO5 Pipework & Brazing
maintenance + CITB Essential & Refrigeration Electrics
+ Module 3 - Design principles

Book online: www.airedale.com/training-events

ChillerGuard™ and SafeCool™ Service Plans


maximising your system’s efficiency 24/7

An Airedale service plan provides a planned, call-out service is on hand throughout the year
preventative maintenance package to sustain the with guaranteed response by a fully qualified
optimum efficiency of your system and enable Airedale engineer. The service plan also ensures
the user to see real savings in energy costs F Gas compliance and incorporates a full parts
and reduced carbon emissions. A priority, 24/7 and labour warranty for the first 12 months.
emergency helpline; professional support and For more information visit www.airedale.com

* For customers outside the UK, our international distributors trained by Airedale would be pleased to offer service on Airedale units
Distributed by:

ISO 14001 ISO 9001


EMS52086 FM00542

Airedale International Air Conditioning Limited | Leeds Road, Rawdon, Leeds LS19 6JY, England
Tel: +44 (0) 113 239 1000 Fax: +44 (0) 113 250 7219 E-Mail: enquiries@airedale.com

All specifications are subject to change without prior notice | ENG-PRODG-07-13