Professional Documents
Culture Documents
PROBLEM INDICATOR
SYMPTOM
Faulty RRU
Faulty boards
Hardware issues
Faulty connectors
Faulty cables
Faulty filters
External
interference
radio stations
SYMPTOM INDICATOR
TROUBLESHOOTING
not all cells of the same from the antenna ports, connect the jumper cable of
site affected, but all cells another cell of the same site that is not affected by
of the same RRU are
the RTWP to the suspected RRU, high RTWP appears
affected
on that cell during a trace then RRU is bad
all cells affected of the
nodeB are affected
SOLUTION
change RRU
change board
tighten connectors
change cables
change filters
Report to operator
Report to operator
1. restore the
availability of
neighboring cells 2.
carry out traffic
balancing between
neighboring cells 3.
reduce power ramp
step and initial access
power parameters of
the cell
4. carry out
physical optimization
i.e downtilt the cell