You are on page 1of 40

DriveIT Low Voltage AC Drive

ACS800 Catalogue
Related tools and accessories

3AFE 64572504 REV E EN 17.10.2003

Contents
pages

General
ABB

5
IT

Industrial for drives

AC drives

Products
ACS800 for AC motors, compact and complete

6-7

ACS800 Wall-mounted single drive

8 - 10

ACS800 Free standing single drive

8 - 10

ACS800 Single drive modules

11 - 12

ACS800 Cabinet built single drive

13 - 15

ACS800 4-Quadrant drive

16 - 17

Standard application software

18

Start-up Assistant

19

Adaptive Programming

20

Control Solutions
ABBs ready-made Control Solutions for specific drive applications

21

Centrifuge Control

22

Extruder Control

22

Pump and Fan Control

23

Spinning Control & Traverse Control

24

Crane Drive Control

25

Others
ACS800 I/O

26

Control Panel

27

Fieldbus Control

28

Dynamic Braking

29 - 30

Output filters

31 - 32

Programming Tool - DriveAP

33

Integration Tool - DriveOPC

34

Engineering Tool - DriveSize

35

Start-up and Maintenance Tool - DriveWindow 2

36

Start-up and Maintenance Tool - DriveWindow Light 2.1

37

Remote Monitoring Tool

38

Energy saving with ACS800

39

3AFE 64572504 REV E EN 17.10.2003

DriveIT Low Voltage AC Drive


ACS800

3AFE 64572504 REV E EN 17.10.2003

DriveIT Low Voltage AC Drive


ACS800

ABB
ABB is one of the largest technology
companies in the world with broad
industry knowledge and geographic
scope. It has about 133,000 employees in around 100 countries and
occupies a leading position (1, 2 or
3) in each industry and product
areas it serves.
ABB offers complete industry and
process specific solutions, from
products to turnkey projects in
utilities, oil, gas and petrochemicals,
manufacturing and consumer
industries, and process industries.
ABB offers world-class collaborative
business platforms and solutions
based on IndustrialIT open architecture software.

IndustrialIT for drives


As a key element of its business
strategy, ABB has committed to a
broad program of product development and positioning under the
Industrial IT umbrella. This initiative
is geared towards increasing standardization of ABB products as the
building blocks of larger solutions,
while building in functionality that
will allow multiple products to
interact seamlessly as components
of real-time automation and information systems.
At the product level ABB's Industrial IT
architecture ensures that ABB
products can interoperate perfectly.
Only products that satisfy a complete list of requirements stipulated
by Industrial IT are certified to bear
the Industrial IT enabled symbol, a
special mark that indicates that the
product can be easily integrated
into the Industrial IT architecture, in
a plug & produce manner.

Standardization and an architecture


based on open standards increase
engineering efficiency, speed of
implementation and quality. The
final result is higher productivity
and more output from your plant.
Through versatile connectivity the
drives made by ABB can be easily
integrated with different process
automation systems fulfilling the
requirements of Industrial IT.
Our DriveIT drive products provide
the performance, energy savings
and life extension that the customers have come to expect from ABB.

AC drives
AC drives are used to control the
speed and torque of a standard
induction motor, the workhorse of
the industry. ABB is a market leader
in both motors and drives worldwide.
AC drive technology extends the
motor speed range from zero to
high above the rated speed, increasing the productivity of the driven
process. When a low capacity is
enough, the drive reduces the
machine speed and saves energy.
Accurate speed control of the
manufacturing process optimizes
the quality of the end product. The
Direct Torque Control (DTC)
developed by ABB has improved
control accuracy by making speed
encoders unnecessary.

3AFE 64572504 REV E EN 17.10.2003

ACS800
up to 2800 kW AC motors,
compact and complete.

Common technology for


different applications
One of the main benefits of the
ACS800 series is a wide range of
drive products with common
technologies. This includes Start-up
Assistant, Adaptive Programming
and DTC, common user and process interfaces, software tools for
sizing, commissioning and maintenance and common spare parts.

Premium Technology - DTC

Start-up Assistant

The heart of the ACS800 is DTC Direct Torque Control, its first class
motor control system. The consistently excellent performance of the
ACS800 guarantees that the drive
is not the limiting factor in your
process.

The ABB AC drives have always


been top of their class in userfriendliness. The new product series
brings a whole new meaning to
user-friendliness. Thanks to the
Start-up Assistant, the commissioning and tuning of a high
performance drive could not be
easier.

DTC technology is well proven in


various applications and demanding
environments guaranteeing the high
reliability of the drive.

ACS800 voltage power range


Motor
[kW]
2800
1900
1450

The ACS800 goes one step further


compared to normal parameter
programming with the addition of
Adaptive Programming. It is like
having a small PLC inside your
drive. Adaptive Programming needs
no additional hardware or software
but is always there when needed.

Integration and Compact


Design

800
200
110
37
5.5
1.5
1.1
0.55
200

Adaptive Programming

240

380

3AFE 64572504 REV E EN 17.10.2003

415

500

690

Supply [V]

Anything that is required from an


AC drive, like EMC and harmonic
filters, is inside the drive, so no
extra space or cabling is needed.
Furthermore, there is always space
inside the ACS800 for three option
modules for I/O extensions,
fieldbuses, pulse encoder interface
or a PC connection.

Environmentally sound
products

Technical specifications for the


ACS800-01/-02/-04/-07/-17

ABB is a signatory to the ICC


(International Chamber of Commerce) Business Charter for
Sustainable Development and is
working towards fulfilling its requirements. ABB AC drives follow
all 16 ICC principles and the basic
function of variable speed drives
is to minimize the environmental
impact by matching the speed of
the driven machine to the actual
need in the process. This often
means that the environmental load
reduction in the process is ten times
more than the environmental load
caused by the manufacture, transport and disposal of the drives.

Mains connection

The manufacturing of AC drives


complies with ISO 14001 standards.

3-Phase supply voltage: U2IN = 208240 V 10%


U3IN = 380415 V 10%
U5IN = 380500 V 10%
U7IN = 525690 V 10%
Frequency:

48...63 Hz

Power factor:

cos1 = 0.98 (fundamental)


cos = 0.93...0.95 (total)

Power factor (ACS800-17): cos1 = 1 (fundamental)


cos = 0.99 (total)

Efficiency
At nominal power:
ACS800-0x
ACS800-17

98%
97%

Motor connection
3-Phase output voltage: 0...U2IN/U3IN/U5IN//U7IN
Frequency control:

0...300 Hz
0...120 Hz with du/dt filters

Field weakening point:

8...300 Hz

Motor control software:

ABBs Direct Torque Control (DTC)

Torque control:
Open loop
Closed loop

Torque step rise time:


<5 ms with nominal torque
<5 ms with nominal torque
Non-linearity:
4% with nominal torque
1% with nominal torque

Open loop
Closed loop
Speed control:
Open loop
Closed loop
Open loop
Closed loop

Static accuracy:
10% of motor slip
0.01% of nominal speed
Dynamic accuracy:
0.3...0.4%sec. with 100% torque step
0.1...0.2%sec. with 100% torque step

Environmental limits
Ambient temperature:
Transportation:
Storage:
Operation:

Common software features,


please see pages 18 - 20.

-40...+70C
-40...+70C
-15...+50C, no frost allowed
40...50C at reduced output current (1%/1C).

Operation (ACS800-17):

0...+50C

Relative humidity:

40...50C at reduced output current (1.5%/1C).


5 to 95%, no condensation allowed.

Cooling method:

Dry clean air

Altitude:

0...1000 m without derating


1000...4000 m with derating (690 V units 1000...2000 m
with derating)
3AFE 64572504 REV E EN 17.10.2003

ACS800 Wall-mounted single drive


ACS800-01, up to 110 kW

ACS800 Free standing single drive


ACS800-02, up to 500 kW

Compact and Complete


single drives
ACS800-01 and -02 single drives
offer you all that you need. They
are available in IP 21 or IP 55
(ACS800-01 only) degrees of protection. The drives up to 110 kW are
compact, wall-mounted ACS800-01
drives and from 90 kW up to 500 kW
bookshelf-style ACS800-02 drives
with a new innovative free-standing
enclosure. The difference between
the ACS800-01 and the ACS800-02
is the mechanical construction otherwise the drives are similar.

Fits anywhere
Both ACS800-01 and ACS800-02
drives are extremely compact
without sacrificing user-friendliness.
The ACS800-02 has a unique,
extremely compact bookshelf
design. When using bookshelf
mounting, even side-by-side installation is possible. In addition to
bookshelf mounting, the ACS800-02
offers a possibility for flat type
mounting enabling you to optimise
the width or depth depending on
your needs.

for harmonic filtering and drive


protection, extensive and flexible
I/O, user-friendly control panel with
a Start-up Assistant feature and a
silent long-lifetime cooling fan.
If even more features are needed, a
wide selection of inbuilt options is
available. An enclosure extension
is also available for the ACS800-02,
further enhancing its versatility.

Main standard hardware


features:
Common in-built features:
IP 21 protection class
Compact design
Harmonic filtering choke inside
Long life time cooling fan and
capacitors
Extensive, programmable I/O
Inputs galvanically isolated
Three I/O and fieldbus extension
slots inside
Alphanumeric, multilingual
control panel with a Start-up
Assistant feature
Large power terminals allowing
use of over sized or aluminium
cable

Everything inside
From the smallest ACS800-01 to
the biggest ACS800-02 there is an
extensive selection of in-built
features and accessories. The
standard features include a choke

3AFE 64572504 REV E EN 17.10.2003

Additionally in ACS800-02:
Free standing
Two mounting directions as
standard
Very narrow bookshelf design

Accessories for the


ACS800-01 and -02:
Brake chopper
EMC filter / two alternatives:
EN 61800-3, 2nd environment,
unrestricted distribution
EN 61800-3, 1st environment,
restricted distribution
Analogue and digital I/O
extension modules
Fieldbus modules
Pulse encoder interface module
Accessories for the ACS800-01:
IP 55
Accessories for the ACS800-02:
Common mode filters for motor
protection
Accessories requiring enclosure
extension for the ACS800-02:
Fuse switch
Contactor with emergency stop
pushbutton
1 or 2 thermistor relays
3 Pt100 relays
Cable top entry and exit
Customer terminal block
In addition several external accessories available like du/dt filter,
brake resistor.

Cooling air flow


requirements
Type

Nominal

No-overload

Light-overload

Heavy-duty

Noise

Heat

ratings

use

use

use

level

dissipation

dBA

m3/h

V).
62
62
62
62
62
62
62
62
62
62
65
65
65
65
65
65
71
71
71
72
72
72
72
72
72

100
100
100
120
140
160
200
250
340
440
530
610
810
1190
1190
1440
2750
3350
3950
5300
6050
6550
7450
7850
8300

35
35
35
35
35
69
69
69
103
103
168
168
168
405
405
405
540
540
540
1220
1220
1220
1220
1220
1220

62
62
62
62
62
62
62
62
62
62
65
65
65
65
65
65
71
71
71
72
72
72
72
72

100
120
140
160
200
250
340
440
530
610
810
990
1190
1440
1940
2310
3050
3700
4300
6600
7200
8100
8650
9100

35
35
35
35
35
69
69
69
103
103
168
168
168
405
405
405
540
540
540
1220
1220
1220
1220
1220

I cont.max
A

P cont.max
kW

max

IN
A

PN
kW

P hd
kW

hd

Frame
size

Three phase supply voltage 208, 220, 230 or 240 V. The power ratings are valid at nominal voltage (230
ACS800-01-0001-2
5.1
6.5
1.1
4.7
0.75
3.4
0.55
R2
ACS800-01-0002-2
6.5
8.2
1.5
6.0
1.1
4.3
0.75
R2
ACS800-01-0003-2
8.5
10.8
1.5
7.7
1.5
5.7
1.1
R2
ACS800-01-0004-2
10.9
13.8
2.2
10.2
2.2
7.5
1.5
R2
ACS800-01-0005-2
13.9
17.6
3
12.7
3
9.3
2.2
R2
ACS800-01-0006-2
19
24
4
18
4
14
3
R3
ACS800-01-0009-2
25
32
5.5
24
5.5
19
4
R3
ACS800-01-0011-2
34
46
7.5
31
7.5
23
5.5
R3
ACS800-01-0016-2
44
62
11
42
11
32
7.5
R4
ACS800-01-0020-2
55
72
15
50
11
37
7.5
R4
ACS800-01-0025-2
72
86
18.5
69
18.5
49
11
R5
ACS800-01-0030-2
86
112
22
80
22
60
15
R5
ACS800-01-0040-2
103
138
30
94
22
69
18.5
R5
ACS800-01-0050-2
141
164
37
132
37
97
30
R6
ACS800-01-0060-2
166
202
45
155
45
115
30
R6
ACS800-01-0070-2
202
282
55
184
55
141
37
R6
ACS800-02-0080-2
214
326
55
211
55
170
45
R7
ACS800-02-0100-2
253
404
75
248
75
202
55
R7
55
R7
ACS800-02-0120-2
295
432
90
290
90
240 1)
ACS800-02-0140-2
405
588
110
396
110
316
90
R8
ACS800-02-0170-2
447
588
132
440
132
340
90
R8
ACS800-02-0210-2
528
588
160
516
160
370
110
R8
ACS800-02-0230-2
613
840
160
598
160
480
132
R8
160
R8
ACS800-02-0260-2
693
1017
200
679
200
590 2)
3)
ACS800-02-0300-2
720
1017
200
704
200
635
200
R8
Three phase supply voltage 380, 400 or 415 V. The power ratings are valid at nominal voltage (400 V).
ACS800-01-0003-3
5.1
6.5
1.5
4.7
1.5
3.4
1.1
R2
ACS800-01-0004-3
6.5
8.2
2.2
5.9
2.2
4.3
1.5
R2
ACS800-01-0005-3
8.5
10.8
3
7.7
3.0
5.7
2.2
R2
ACS800-01-0006-3
10.9
13.8
4
10.2
4.0
7.5
3.0
R2
ACS800-01-0009-3
13.9
17.6
5.5
12.7
5.5
9.3
4.0
R2
ACS800-01-0011-3
19
24
7.5
18
7.5
14
5.5
R3
ACS800-01-0016-3
25
32
11
24
11
19
7.5
R3
ACS800-01-0020-3
34
46
15
31
15
23
11
R3
ACS800-01-0025-3
44
62
22
41
18.5
32
15
R4
ACS800-01-0030-3
55
72
30
50
22
37
18.5
R4
ACS800-01-0040-3
72
86
37
69
30
49
22
R5
ACS800-01-0050-3
86
112
45
80
37
60
30
R5
ACS800-01-0060-3
103
138
55
94
45
69
37
R5
ACS800-01-0070-3
141
164
75
132
55
97
45
R6
ACS800-01-0100-3
166
202
90
155
75
115
55
R6
ACS800-01-0120-3
202
282
110
184
90
141
75
R6
ACS800-02-0140-3
206
326
110
202
110
163
90
R7
ACS800-02-0170-3
248
404
132
243
132
202
110
R7
1)
ACS800-02-0210-3
289
432
160
284
160
240
132
R7
ACS800-02-0260-3
445
588
200
440
200
340
160
R8
ACS800-02-0320-3
521
588
250
516
250
370
200
R8
ACS800-02-0400-3
602
840
315
590
315
477
250
R8
315
R8
ACS800-02-0440-3
693
1017
355
679
355
590 2)
ACS800-02-0490-3
720
1017
400
704
400
635 3)
355
R8

Air flow

Enclosure
Degree of Protection:
IP 21 (Standard)
IP 55 (Optional) for ACS800-01
Paint color:
NCS 1502-Y (RAL 90021/PMS 420C)

Type

R2
R3
R4
R5
R6
R7
R8
*)

IP 21

IP 55

H1
mm

H2
mm

W1
mm

W2
mm

Depth
mm

Weight
kg

Weight with
enclosure
extension *) kg

H1
mm

W1
mm

Depth
mm

Weight
kg

405
471
606
739
880
1507
2024

370 C)
420 C)
490 C)
602 C)
700 C)
N/A
N/A

165
173
240
265
300
250 A)
347 A)

N/A
N/A
N/A
N/A
N/A
602
793

226
265
274
286
400
520 A) B)
617 A) B)

9
12
26
37
67
110
240

N/A
N/A
N/A
N/A
N/A
234
450

528
528
774
775
923
N/A
N/A

263
263
377
377
420
N/A
N/A

242
273
278
308
427
N/A
N/A

16
18
32
50
77
N/A
N/A

H1 = Height with cable connection box


H2 = Height without cable connection box
W1 = Width of the standard unit
W2 = Width with enclosure extension
N/A = not available
A)
The dimensions apply to bookshelf
mounting. In flat type mounting the
width and depth change places.
B)
With enclosure extension the depth is
increased by 25 mm due to the switch
fuse handle.
C)
ACS800-01 without cable connection box
does not fulfill IP 21 requirements.

Weights are for the basic configuration with switch fuse, but without contactor and other options.

3AFE 64572504 REV E EN 17.10.2003

Cooling air flow


requirements
Type

Nominal

No-overload

Light-overload

Heavy-duty

Noise

Heat

ratings

use

use

use

level

dissipation

dBA

I cont.max
A

max

P cont.max
kW

IN
A

PN
kW

hd

P hd
kW

Frame
size

Three phase supply voltage 380, 400, 415, 440, 460, 480 or 500 V. The power ratings are valid at nominal voltage (500 V).
ACS800-01-0004-5
4.9
6.5
2.2
4.5
2.2
3.4
1.5
R2
62
120
ACS800-01-0005-5
6.2
8.2
3
5.6
3.0
4.2
2.2
R2
62
140
ACS800-01-0006-5
8.1
10.8
4
7.7
4.0
5.6
3.0
R2
62
160
ACS800-01-0009-5
10.5
13.8
5.5
10
5.5
7.5
4.0
R2
62
200
ACS800-01-0011-5
13.2
17.6
7.5
12
7.5
9.2
5.5
R2
62
250
ACS800-01-0016-5
19
24
11
18
11
13
7.5
R3
62
340
ACS800-01-0020-5
25
32
15
23
15
18
11
R3
62
440
ACS800-01-0025-5
34
46
18.5
31
18.5
23
15
R3
62
530
ACS800-01-0030-5
42
62
22
39
22
32
18.5
R4
62
610
ACS800-01-0040-5
48
72
30
44
30
36
22
R4
62
810
ACS800-01-0050-5
65
86
37
61
37
50
30
R5
65
990
ACS800-01-0060-5
79
112
45
75
45
60
37
R5
65
1190
ACS800-01-0070-5
96
138
55
88
55
69
45
R5
65
1440
ACS800-01-0100-5
124
164
75
115
75
88
55
R6
65
1940
ACS800-01-0120-5
157
202
90
145
90
113
75
R6
65
2310
ACS800-01-0140-5
180
282
110
163
110
141
90
R6
65
2810
ACS800-02-0170-5
196
326
132
192
132
162
110
R7
71
3050
ACS800-02-0210-5
245
384
160
240
160
192
132
R7
71
3850
ACS800-02-0260-5
289
432
200
284
200
224
160
R7
71
4550
ACS800-02-0320-5
440
588
250
435
250
340
200
R8
72
6850
ACS800-02-0400-5
515
588
315
510
315
370
250
R8
72
7850
ACS800-02-0440-5
550
840
355
545
355
490
315
R8
72
7600
355
R8
72
8100
ACS800-02-0490-5
602
840
400
590
400
515 2)
ACS800-02-0550-5
684
1017
450
670
450
590 2)
400
R8
72
9100
ACS800-02-0610-5
718
1017
500
704
500
632 3)
450
R8
72
9700
Three phase supply voltage 525, 575, 600, 660 or 690 V. The power ratings are valid at nominal voltage (690 V).
ACS800-01-0011-7
13
14
11
11.5
7.5
8.5
5.5
R4
62
300
ACS800-01-0016-7
17
19
15
15
11
11
7.5
R4
62
340
ACS800-01-0020-7
22
28
18.5
20
15
15
11
R4
62
440
ACS800-01-0025-7
25
38
22
23
18.5
19
15
R4
62
530
ACS800-01-0030-7
33
44
30
30
22
22
18.5
R4
62
610
ACS800-01-0040-7
36
54
30
34
30
27
22
R4
62
690
ACS800-01-0050-7
51
68
45
46
37
34
30
R5
65
840
ACS800-01-0060-7
57
84
55
52
45
42
37
R5
65
1010
ACS800-01-0070-7
79
104
75
73
55
54
45
R6
65
1220
ACS800-01-0100-7
93
124
90
86
75
62
55
R6
65
1650
ACS800-01-0120-7
113
172
110
108
90
86
75
R6
65
1960
Nominal Ratings:
Icont.max: rated current available continuously without
overloadability at 40C.
Imax: maximum output current. Available for 10 s at
start, otherwise as long as allowed by drive
temperature. Note: max. motor shaft power is
150% Phd.

The current ratings are the same regardless of the


supply voltage within one voltage range.
The ratings apply at 40C ambient temperature.
At higher temperatures (up to 50C) the derating is
1%/1C.
Notes:
50% overload available if Tamb < 25C.
If Tamb = 40C, max overload for 1 min is 37%.

1)

Typical Ratings:
No-overload use
Pcont.max: typical motor power in no-overload use.
Light-overload use
IN: continuous current allowing 110% IN for
1min/ 5 min at 40C.
PN: typical motor power in light-overload use.
Heavy-duty use
Ihd: continuous current allowing 150% Ihd for
1min/ 5 min at 40C.
Phd: typical motor power in heavy-duty use.

10

3AFE 64572504 REV E EN 17.10.2003

2)

50% overload available if Tamb < 30C.


If Tamb = 40C, max overload for 1 min is 40%.

3)

50% overload available if Tamb < 20C.


If Tamb = 40C, max overload for 1 min is 30%.

4)

Higher value available if output frequency is above


41Hz.

Air flow

m3/h
35
35
35
35
35
69
69
69
103
103
168
168
168
405
405
405
540
540
540
1220
1220
1220
1220
1220
1220
103
103
103
103
103
103
168
168
405
405
405

ACS800 Single drive modules


ACS800-04, up to 560 kW

Optimized construction
The ACS800-04 has several benefits
that make it the optimal choice for
panel builders.
No special EMC proof cabinets are
needed. In ACS800-04 drives with
in-built EMC filtering, both radiated
and conducted emissions are
restricted to EN 61800-3 limits
without the need for any extra
hardware.
Innovative fixing mechanics which
minimize the number of bolts facilitate the attachment of the drive
module. Fixing of the control unit
and control panel is easy thanks to
the DIN rail mounting and new type
of mounting platform.
The compact size with plenty of
built-in options minimizes both
space requirements and the amount
of assembly work needed.

Easy cabling
The easily accessible power terminals with plenty of space around
them make power cabling for the
ACS800-04 easy. Moreover, a
separate control unit enables easy
access to the I/O terminals. The
control unit can be optimally sited
inside the cabinet to enable access
to the I/O terminals without needing to open the drive module.

The need for busbars and cables in


the cabinet has been minimized by
having the incoming power terminals on the top of the module. This
enables use of the optimal cabling
route.

Maximised flexibility
Thanks to modular design ACS80004 offers wide variety of installation
possibilities. Both bookshelf
mounting for optimised width and
flat type mounting for optimised
depth are available.
Main standard hardware
features:
Optimised design for cabinet
assembly
EMC compliant module
Modular design allowing wide
variety of variants
Easy access to power terminals
Easy access and free location of
I/O terminals
Compact design
Harmonic filtering choke inside
Long life time cooling fan and
capacitors
Extensive, programmable I/O
Inputs galvanically isolated
Three I/O and fieldbus extension
slots inside
Large power terminals allowing
use of over sized or aluminium
cable

There are several other possibilities


to adapt the drive module to
customer needs as well. As examples
are possibility of wall or floor
mounting and possibility of changing the outputs from left to right.
Naturally also the adaptive software
and other standard and optional
features of the ACS800 series are
available.

Accessories for the ACS800-04


In-built options:
Brake chopper
EMC filter:
EN 61800-3, 2nd environment,
unrestricted distribution
Common mode filters for
motor protection
Analogue and digital I/O
extension modules
Fieldbus modules
Pulse encoder interface module
Various output busbar options
(ACS800-04M)
Flat type cabling pedestal
enabling sideways mounting
(ACS800-04M)
Other options:
Control panel and mounting
platform

3AFE 64572504 REV E EN 17.10.2003

11

Cooling air flow


requirements
Type

Nominal

No-overload

Light-overload

Heavy-duty

Noise

Heat

ratings

use

use

use

level

dissipation

dBA

I cont.max
A

max

P cont.max
kW

IN
A

PN
kW

hd

P hd
kW

Frame
size

Air flow

m3/h

Three phase supply voltage 208, 220, 230 or 240 V. The power ratings are valid at nominal voltage (230 V).
ACS800-04/04M-0080-2
214
326
55
211
55
170
45
R7
71
2750
ACS800-04/04M-0100-2
253
404
75
248
75
202
55
R7
71
3350
55
R7
71
3950
ACS800-04/04M-0120-2
295
432
90
290
90
240 1)
ACS800-04/04M-0140-2
405
588
110
396
110
316
90
R8
72
5300
ACS800-04/04M-0170-2
447
588
132
440
132
340
90
R8
72
6050
ACS800-04/04M-0210-2
528
588
160
516
160
370
110
R8
72
6550
ACS800-04/04M-0230-2
613
840
160
598
160
480
132
R8
72
7450
ACS800-04/04M-0260-2
693
1017
200
679
200
590 2)
160
R8
72
7850
ACS800-04/04M-0300-2
720
1017
200
704
200
635 3)
200
R8
72
8300
Three phase supply voltage 380, 400 or 415 V. The power ratings are valid at nominal voltage (400 V).
ACS800-04/04M-0140-3
206
326
110
202
110
163
90
R7
71
3050
ACS800-04/04M-0170-3
248
404
132
243
132
202
110
R7
71
3700
132
R7
71
4300
ACS800-04/04M-0210-3
289
432
160
284
160
240 1)
ACS800-04/04M-0260-3
445
588
200
440
200
340
160
R8
72
6600
ACS800-04/04M-0320-3
521
588
250
516
250
370
200
R8
72
7200
ACS800-04/04M-0400-3
602
840
315
590
315
477
250
R8
72
8100
2)
ACS800-04/04M-0440-3
693
1017
355
679
355
590
315
R8
72
8650
3)
ACS800-04/04M-0490-3
720
1017
400
704
400
635
355
R8
72
9250
Three phase supply voltage 380, 400, 415, 440, 460, 480 or 500 V. The power ratings are valid at nominal voltage (500 V).
ACS800-04/04M-0170-5
196
326
132
192
132
162
110
R7
71
3050
ACS800-04/04M-0210-5
245
384
160
240
160
192
132
R7
71
3850
ACS800-04/04M-0260-5
289
432
200
284
200
224
160
R7
71
4550
ACS800-04/04M-0320-5
440
588
250
435
250
340
200
R8
72
6850
ACS800-04/04M-0400-5
515
588
315
510
315
370
250
R8
72
7850
ACS800-04/04M-0440-5
550
840
355
545
355
490
315
R8
72
7600
2)
ACS800-04/04M-0490-5
602
840
400
590
400
515
355
R8
72
8100
2)
ACS800-04/04M-0550-5
684
1017
450
670
450
590
400
R8
72
9100
3)
ACS800-04/04M-0610-5
718
1017
500
704
500
632
450
R8
72
9700
Three phase supply voltage 525, 575, 600, 660 or 690 V. The power ratings are valid at nominal voltage (690 V).
ACS800-04/04M-0140-7
134
190
132
125
110
95
90
R7
71
2800
ACS800-04/04M-0170-7
166
263
160
155
132
131
110
R7
71
3750
294
160
165/195 4)
160
147
132
R7
71
4250
ACS800-04/04M-0210-7 166/203 4)
ACS800-04/04M-0260-7 175/230 4)
326
160/200 4) 175/212 4) 200 4)
163
160
R7
71
4800
ACS800-04/04M-0320-7
315
433
315
290
250
216
200
R8
72
6150
ACS800-04/04M-0400-7
353
548
355
344
315
274
250
R8
72
6650
ACS800-04/04M-0440-7
396
656
400
387
355
328
315
R8
72
7400
ACS800-04/04M-0490-7
445
775
450
426
400
387
355
R8
72
8450
ACS800-04/04M-0550-7
488
853
500
482
450
426
400
R8
72
8300
ACS800-04/04M-0610-7
560
964
560
537
500
482
450
R8
72
9750
Nominal Ratings:
Icont.max : rated current available continuously without
overloadability at 40C.
IMAX : maximum output current. Available for 10 s at
start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd .
Typical Ratings:
No-overload use
Pcont.max: typical motor power in no-overload use.
Light-overload use
IN: continuous current allowing 110% IN for
1min/ 5 min at 40C.
PN: typical motor power in light-overload use.

Notes:
50% overload available if T amb < 25C.
If Tamb = 40C, max overload for 1 min is 37%.
50% overload available if T amb < 30C.
If Tamb = 40C, max overload for 1 min is 40%.

3)

50% overload available if T amb < 20C.


If Tamb = 40C, max overload for 1 min is 30%.

4)

Higher value available if output frequency is


above 41Hz.

540
540
540
1220
1220
1220
1220
1220
540
540
540
1220
1220
1220
1220
1220
1220
540
540
540
540
1220
1220
1220
1220
1220
1220

Enclosure

1)

2)

540
540
540
1220
1220
1220
1220
1220
1220

Degree of Protection:
IP 00
Paint color:
NCS 1502-Y (RAL 90021/PMS 420C)

Type

Height
mm
RDCU control unit *) 282
*)

Width Depth
mm
mm
126
41

coming with every unit

Bookshelf design
Heavy-duty use
Ihd : continuous current allowing 150% Ihd for
1min/ 5 min at 40C.

Type

Phd: typical motor power in heavy-duty use.

R7
R8

The current ratings are the same regardless of the


supply voltage within one voltage range.
The ratings apply at 40C ambient temperature.
At higher temperatures (up to 50C) the derating is
1%/1C.

3AFE 64572504 REV E EN 17.10.2003

Width
mm
426
571

Depth
mm
467
564

Weight
kg
100
205

Width with cable connection plate for output cables.

Flat type design


Type
R7
R8

12

Height
mm
1121
1558

Height
mm
1152
1589

Width
mm
631
779

Depth
mm
259
356

Weight
kg
100
205

ACS800 Cabinet built single drive


ACS800-07, up to 2800 kW

Customised solutions
ACS800-07 is a cabinet built single
drive designed for industrial applications. It covers a wide power range
and is very compact, the 2800 kW
drive is only 3.2 meters wide. It is
available with IP 21, IP 22, IP 42,
IP 54 and IP 54R protection classes.
The ACS800-07 offers a wide variety
of standardized configurations to
adapt to different application
requirements, from line contactor to
the prevention of unexpected motor
start, or ATEX approved motor
protection.
If your application requires more,
ABBs application engineering
services can add special features
to the standard product such as an
additional cabinet for customer
specific devices to ensure exact
suitability for the application.

Smart module concept


The drives up to 500 kW are based
on a compact single module including rectifier and inverter.
Larger drives consist of separate
rectifier and inverter modules, which
have plug-in power connectors
providing easy maintenance and

redundancy with parallel connected units. The rectifier module


provides 6- or 12-pulse operation
as standard.

Extensive range of features


The ACS800-07 has an extensive
range of inbuilt features and accessories. Typical accessory choices
include extended I/O and fieldbus
options, line contactor, EMC filtering, common mode filtering and
du/dt (voltage rise) filtering, all
mountable within the single
cabinet.
Main standard hardware features
Compact design
IP 21 protection class
Inbuilt harmonic filtering choke
Fuse switch (frames R6-R8)
Main switch (frames nxR8i)
Extensive, programmable I/O,
6- or 12-pulse operation (frames
nxR8i)
Long lifetime cooling fan and
capacitors
Inputs galvanically isolated
I/O and fieldbus extension slots
inside
Alphanumeric multilingual
control panel with Start-up
Assistant feature

Accessories for the ACS800-07:


Analogue and digital I/O extension modules
ATEX approved motor protection
Braking chopper and resistor
Cabinet heater
Common mode filters for motor
protection
Customer terminal block
Du/dt filters
Earth fault monitoring for unearthed network
EMC filter
Fieldbus modules
IP 22, 42, 54 or 54R enclosure
classes
Line contactor with emergency
stop push button
Line fuse switch (frames nxR8i)
Output for fan motor
Prevention of unexpected motor
start
Pulse encoder interface module
Top entry and exit of cables
1 or 2 thermistor relays
3, 5 or 8 Pt100 relays
Plus tailor made accessories through
ABBs application engineering.

3AFE 64572504 REV E EN 17.10.2003

13

Cooling air flow


requirements
Type

Nominal

No-overload

Light-overload

Heavy-duty

Noise

Heat

ratings

use

use

use

level

dissipation

dBA

kW

m3/h

65
65
65
71
71
71
72
72
72
72
72
73
74
74
74
75
76
76

1.44
1.94
2.31
3.05
3.70
4.30
6.60
7.20
8.10
8.65
9.10
13.0
17.7
18.9
25.5
28.0
43.7
49.1

405
405
405
540
540
540
1220
1220
1220
1220
1220
3120
3840
3840
3840
5040
5760
6960

65
65
65
71
71
71
72
72
72
72
72
72
73
74
74
74
75
76
76

1.94
2.31
2.81
3.05
3.85
4.55
6.85
7.85
7.60
8.10
9.10
9.70
14.4
18.6
21.1
26.6
31.5
48.1
57.0

405
405
405
540
540
540
1220
1220
1220
1220
1220
1220
3120
3840
3840
3840
5040
5760
6960

65
65
65
71
71
71
71
72
72
72
72
72
72
73
73
73
74
75
75
76
76
78
78

1.22
1.65
1.96
3.00
3.75
4.45
4.80
6.15
6.65
7.40
8.45
8.30
9.75
15.3
18.5
19.4
23.9
29.2
35.4
42.2
56.5
68.3
91.2

405
405
405
540
540
540
540
1220
1220
1220
1220
1220
1220
3120
3120
3120
3840
5040
5040
6240
6960
9360
10080

I cont.max
A

I max
A

P cont.max
kW

IN
A

PN
kW

hd

P hd
kW

Frame
size

Three phase supply voltage 380, 400 or 415 V. The power ratings are valid at nominal voltage (400 V).
ACS800-07-0070-3
141
164
75
132
55
97
45
R6
ACS800-07-0100-3
166
202
90
155
75
115
55
R6
ACS800-07-0120-3
202
282
110
184
90
141
75
R6
ACS800-07-0140-3
206
326
110
202
110
163
90
R7
ACS800-07-0170-3
248
404
132
243
132
202
110
R7
132
R7
ACS800-07-0210-3
289
432
160
284
160
240 1)
ACS800-07-0260-3
445
588
200
440
200
340
160
R8
ACS800-07-0320-3
521
588
250
516
250
370
200
R8
ACS800-07-0400-3
602
840
315
590
315
477
250
R8
2)
ACS800-07-0440-3
693
1017
355
679
355
590
315
R8
ACS800-07-0490-3
720
1017
400
704
400
635 3)
355
R8
ACS800-07-0610-3
879
1313
500
844
500
657
400
1xD4 + 2xR8i
ACS800-07-0770-3
1111
1519
630
1067
630
830
450
2xD4 + 2xR8i
ACS800-07-0870-3
1255
1876
710
1204
710
938
500
2xD4 + 2xR8i
ACS800-07-1030-3
1452
1987
800
1394
800
1086
630
2xD4 + 2xR8i
ACS800-07-1230-3
1770
2648
1000
1700
1000
1324
710
2xD4 + 3xR8i
ACS800-07-1540-3
2156
2950
1200
2070
1200
1612
900
3xD4 + 3xR8i
ACS800-07-1850-3
2663
3983
1450
2557
1450
1992
1120
3xD4 + 4xR8i
Three phase supply voltage 380, 400, 415, 440, 460, 480 or 500 V. The power ratings are valid at nominal voltage (500 V).
ACS800-07-0100-5
124
164
75
115
75
88
55
R6
ACS800-07-0120-5
157
202
90
145
90
113
75
R6
ACS800-07-0140-5
180
282
110
163
110
141
90
R6
ACS800-07-0170-5
196
326
132
192
132
162
110
R7
ACS800-07-0210-5
245
384
160
240
160
192
132
R7
ACS800-07-0260-5
289
432
200
284
200
224
160
R7
ACS800-07-0320-5
440
588
250
435
250
340
200
R8
ACS800-07-0400-5
515
588
315
510
315
370
250
R8
ACS800-07-0440-5
550
840
355
545
355
490
315
R8
2)
ACS800-07-0490-5
602
840
400
590
400
515
355
R8
2)
ACS800-07-0550-5
684
1017
450
670
450
590
400
R8
ACS800-07-0610-5
718
1017
500
704
500
632 3)
450
R8
ACS800-07-0760-5
883
1318
630
847
630
659
500
1xD4 + 2xR8i
ACS800-07-0910-5
1050
1521
710
1008
710
784
560
2xD4 + 2xR8i
ACS800-07-1090-5
1258
1880
900
1208
900
940
630
2xD4 + 2xR8i
ACS800-07-1210-5
1372
1989
1000
1317
1000
1025
710
2xD4 + 2xR8i
ACS800-07-1540-5
1775
2653
1250
1704
1200
1326
900
2xD4 + 3xR8i
ACS800-07-1820-5
2037
2953
1450
1956
1400
1522
1120
3xD4 + 3xR8i
ACS800-07-2310-5
2670
3990
1900
2563
1850
1995
1400
3xD4 + 4xR8i
Three phase supply voltage 525, 575, 600, 660 or 690 V. The power ratings are valid at nominal voltage (690 V).
ACS800-07-0070-7
79
104
75
73
55
54
45
R6
ACS800-07-0100-7
93
124
90
86
75
62
55
R6
ACS800-07-0120-7
113
172
110
108
90
86
75
R6
ACS800-07-0140-7
134
190
132
125
110
95
90
R7
ACS800-07-0170-7
166
263
160
155
132
131
110
R7
ACS800-07-0210-7
166/203 4)
294
160
165/195 4)
160
147
132
R7
ACS800-07-0260-7
175/230 4)
326
160/200 4)
175/212 4)
200
163
160
R7
ACS800-07-0320-7
315
433
315
290
250
216
200
R8
ACS800-07-0400-7
353
548
355
344
315
274
250
R8
ACS800-07-0440-7
396
656
400
387
355
328
315
R8
ACS800-07-0490-7
445
775
450
426
400
387
355
R8
ACS800-07-0550-7
488
853
500
482
450
426
400
R8
ACS800-07-0610-7
560
964
560
537
500
482
450
R8
ACS800-07-0750-7
628
934
630
603
630
467
500
1xD4 + 2xR8i
ACS800-07-0870-7
729
1084
710
700
710
542
560
1xD4 + 2xR8i
ACS800-07-1060-7
885
1318
800
849
800
659
630
1xD4 + 2xR8i
ACS800-07-1160-7
953
1419
900
914
900
710
710
2xD4 + 2xR8i
ACS800-07-1500-7
1258
1874
1200
1208
1200
937
900
2xD4 + 3xR8i
ACS800-07-1740-7
1414
2107
1400
1358
1400
1053
1000
2xD4 + 3xR8i
ACS800-07-2120-7
1774
2643
1700
1703
1700
1322
1250
2xD4 + 4xR8i
ACS800-07-2320-7
1866
2780
1900
1792
1800
1390
1400
3xD4 + 4xR8i
ACS800-07-3190-7
2665
3970
2600
2559
2500
1985
1900
3xD4 + 6xR8i
ACS800-07-3490-7
2770
4127
2800
2659
2700
2063
2100
4xD4 + 6xR8i

14

3AFE 64572504 REV E EN 17.10.2003

Air flow

Nominal Ratings:
Icont.max: rated current available continuously
without overloadability at 40C.

Notes:
1)
50% overload available if Tamb < 25C.
If Tamb = 40C, max overload for 1 min is 37%.

Imax: maximum output current. Available for


10 s at start, otherwise as long as allowed by
drive temperature. Note: max. motor shaft
power is 150% Phd.

2)

50% overload available if Tamb < 30C.


If Tamb = 40C, max overload for 1 min is 40%.

3)

50% overload available if Tamb < 20C.


If Tamb = 40C, max overload for 1 min is 30%.

4)

Higher value available if output frequency is


above 41Hz.

5)

630 mm for types ACS800-07-0120-3 and


0140-5 if equipped with du/dt filter.

Typical Ratings:
No-overload use
Pcont.max: typical motor power in no-overload
use.
Light-overload use
IN: continuous current allowing 110% IN for
1min/ 5 min at 40C.
PN: typical motor power in light-overload use.
Heavy-duty use
Ihd: continuous current allowing 150% Ihd for
1min/ 5 min at 40C.
Phd: typical motor power in heavy-duty use.
The current ratings are the same regardless
of the supply voltage within one voltage
range.
The ratings apply at 40C ambient temperature.
At higher temperatures (up to 50C) the
derating is 1%/1C.

Enclosure
Degr
ee of Pr
otection:
Degree
Protection:
IP 21 (Standard)
IP 22, IP 42, IP 54, IP54R (Optional)
Paint color:
Light beige RAL 7035 semi-gloss

Frame
size
R6
R7
R8
1xD4 + 2xR8i
2xD4 + 2xR8i
2xD4 + 3xR8i
2xD4 + 4xR8i
3xD4 + 3xR8i
3xD4 + 4xR8i
3xD4 + 6xR8i
4xD4 + 6xR8i

Width *)

Width with line


fuse switch *)

1330
1630
1830
2230
2030
2430
2830
3230

430 5)
830
830
1730
2030
2230
2630
2630
3030
3430
4030

Height *)
Height *) Depth *) Depth top
IP 21/22/42
IP 54
entry/exit *)
2130
2130
2130
2130
2130
2130
2130
2130
2130
2130
2130

2315
2315
2315
2315
2315
2315
2315
2315
2315
2315
2315

646
646
646
646
646
646
646
646
646
646
646

646
646
646
730
730
730
730
730
730
730
730

Weight
kg

Weight (kg) with


line fuse switch

890
1200
1350
1680
1540
1870
2170
2520

300
400
500
1100
1410
1560
1890
1800
2130
2430
2940

*) mm

3AFE 64572504 REV E EN 17.10.2003

15

ACS800 4-Quadrant drive


Air cooled regenerative drive.
ACS800-17, up to 1120 kW

Complete 4-Quadrant drive

Energy savings

The high performance ACS800-17


4-Quadrant drive allows full power
flow in motoring and generating.
Transition between modes is fast
due to the ultrafast DTC control
method. Stepping from Pn to -Pn or
vice versa takes only few milliseconds. No dead time in transition is
needed. The drive gives full output
voltage and even more. Output
voltage can be boosted, which
means that 100% output voltage is
available even when the input
voltage is 90%.

Most of the motor drive costs are


energy costs. Often the investment
is only a small fraction of total
costs. Compared with the other
braking methods like mechanical
and resistor braking, the energy
savings can be significant. Braking
resistors also take up installation
space and the handling of waste
heat can be a problem.

Friendly but robust power


line
Power companies set limits for the
permissible harmonic content of
current and voltage in order to
prevent damage to equipment in the
same environment. The ACS800-17
removes low order harmonics with
line converter DTC control and high
order harmonics with an LCL filter.
The result is very clean power for
6, 12, 18 and 24 pulse rectifier
solutions. The ultrafast DTC can
even compensate for fast variations
in line voltage. There is no risk of
component damage due to voltage
drops as in thyristor-based rectifiers
in AC and DC drives.
16

3AFE 64572504 REV E EN 17.10.2003

Easy and flexible


The standard software contains the
Adaptive Programming feature that
enables the user to make small
modifications to the software. Other
software alternatives are also
available for special applications.
There are two features that facilitate
commissioning: the line converter is
a plug and play product, so no
settings are needed. The motor
inverter parameters can be easily
adjusted from control panel with
the new interactive software, Startup Assistant.

LCL filter
ACS800 main modules

Excellent supply side


features
The unique DTC/LCL filter features:
Fundamental power factor unity
Extremely low current and
voltage harmonics
Very small commutating notches
DTC type control has several
advantages:
Ultra-fast response to changes
No fixed switching frequency,
resonating risk avoided
Switching only when needed,
less switching stress
Other features resulting from
the DTCs high stability:
Needs no tuning according to
grid inductance
Plug and play line inverter

Line
inverter
(rectifier)

Motor
inverter

Motor

Excellent motor side


features
The active line rectifier together
with DTC ensures robust behaviour
even in demanding conditions.
Torque is always stable even
with unstable net voltage
Excellent line voltage dip proof
operation
Extremely fast and smooth
operation in motoringregenerating-motoring transitions
Nominal ratings
Type

cont max

P cont max
kW

The motor converter uses the


standard ACS800 DTC motor control. This ultrafast control loop
enables fast responses to load and
line voltage changes. The adjustable
DC voltage boost function makes it
possible to shift the field weakening
point to higher frequencies. In many
cases this feature enables a one size
smaller motor to be selected.

150% duty cycle

200% duty cycle

I_4/5 min

I_50/60 s

I_10/60 s

Frame
size

A (AC)

I max
A (AC)

A (AC)

I_1/5 min
A (AC)

In moderate voltage drops the


control can maintain full DC voltage and the motors get full power.
In heavy voltage drops power
cannot be obtained from the line,
but the drive can be kept ready to
produce power immediately when
voltage returns. The time between
maximum motoring and regenerating power is in the range of
milliseconds.

Information for units and cabinets


Height 1)
mm

Width 2)
mm

Weight

Noise

Ploss

Air flow

kg

level
dB

kW

m3/h

4.1
6.0
7.3
8.9
11.2
13.9
22.0
27.2
31.7
39.3

1920
3650
3650
3650
3650
3650
7280
7280
10330
10330

3.4
4.9
7.2
8.8
11.1
13.7
17.4
27.3
31.7
38.9
48.7

1920
1920
3650
3650
3650
3650
3650
7280
7280
10330
10330

7.2
8.8
10.9
13.4
17.2
27.0
31.3
38.1
48.7

3650
3650
3650
3650
3650
7280
7280
10330
10330

Three phase supply voltage 380, 400 or 415 V. The power ratings are valid at nominal voltage (400 V).
ACS800-17-0120-3
178
90
147
221
147
294
R7i
2130
730
305
63
ACS800-17-0185-3
259
132
194
291
178
356
R8i
2130
1230
625
63
ACS800-17-0225-3
312
160
234
351
216
432
R8i
2130
1230
625
63
ACS800-17-0265-3
379
200
284
426
260
520
R8i
2130
1230
625
63
ACS800-17-0335-3
474
250
356
533
316
632
R9i
2130
1230
655
63
ACS800-17-0405-3
576
315
432
648
395
790
R9i
2130
1230
655
63
ACS800-17-0630-3
907
500
680
1020
600
1200
R11i
2130
3630
1490
68
ACS800-17-0765-3
1094
630
821
1231
751
1502
R11i
2130
3630
1490
68
ACS800-17-0935-3
1336
710
1002
1503
901
1802
R12i
2130
4630
2530
71
ACS800-17-1125-3
1624
900
1218
1827
1126
2252
R12i
2130
4630
2530
71
Three phase supply voltage 380, 400, 415, 440, 460, 480 or 500 V. The power ratings are valid at nominal voltage (500 V).
ACS800-17-0100-5
112
75
84
126
84
168
R6i
2130
730
305
63
ACS800-17-0140-5
164
110
135
203
135
270
R7i
2130
730
305
63
ACS800-17-0215-5
246
160
185
277
164
328
R8i
2130
1230
625
63
ACS800-17-0255-5
295
200
221
332
200
400
R8i
2130
1230
625
63
ACS800-17-0325-5
368
250
276
414
240
480
R8i
2130
1230
625
63
ACS800-17-0395-5
448
315
336
504
300
600
R9i
2130
1230
655
63
ACS800-17-0495-5
565
400
424
636
365
730
R9i
2130
1230
655
63
ACS800-17-0770-5
887
630
665
998
570
1140
R11i
2130
3630
1490
68
ACS800-17-0935-5
1073
710
805
1208
694
1388
R11i
2130
3630
1490
68
ACS800-17-1090-5
1263
900
947
1421
855
1710
R12i
2130
4630
2530
71
ACS800-17-1385-5
1593
1120
1195
1793
1040
2080
R12i
2130
4630
2530
71
Three phase supply voltage 525, 575, 600, 660 or 690 V. The power ratings are valid at nominal voltage (690 V).
ACS800-17-0205-7
176
160
132
198
127
254
R8i
2130
1230
625
63
ACS800-17-0255-7
210
200
158
236
150
300
R8i
2130
1230
625
63
ACS800-17-0315-7
264
250
198
297
179
358
R8i
2130
1230
625
63
ACS800-17-0375-7
310
315
233
349
225
450
R9i
2130
1230
655
63
ACS800-17-0485-7
410
400
308
461
265
530
R9i
2130
1230
655
63
ACS800-17-0750-7
630
630
473
709
428
856
R11i
2130
3630
1730
68
ACS800-17-0900-7
755
710
566
849
504
1008
R11i
2130
3630
1730
68
ACS800-17-1045-7
874
900
656
983
641
1282
R12i
2130
4630
2530
71
ACS800-17-1385-7
1156
1120
867
1301
755
1510
R12i
2130
4630
2530
71

Notes:
1)
Cabinet height is 2130 mm, 2072 mm for IP 54R
2)
An additional 400 mm is required in frame size R11 with top exits
An additional 600 mm is required in frame size R12 with top exits
Cabinet depth is 731 mm
Dimensions limit the number of options in frames R6 / R7 / R8 / R9.

Enclosure
Degree of Protection:
IP 21 (Standard)
IP 22, IP 42, IP 54R (Optional)
Paint color:
Light beige RAL 7035 semi-gloss

Alternatives in reducing line harmonics


6 pulse rectifier

12 pulse rectifier

18 pulse rectifier

ACS800-17

Transformer and cabling simple

Transformer and cabling


complicated

Transformer and cabling


complicated

Transformer and cabling simple

Current very distorted >Ithd 30%

Current distorted >Ithd 12%

Current wave form good >Ithd 6%

Current wave form best Ithd 4%

3AFE 64572504 REV E EN 17.10.2003

17

Standard application software

Based on the Direct Torque Control


technology, the ACS800 offers highly
advanced features as standard.
ACS800 standard application software provides solution virtually to
all AC drives applications.

The standard application


macros
The ACS800 features built-in, preprogrammed application macros for
configuration of such parameters as
inputs, outputs and signal processing.
FACTORY SETTINGS for basic
industrilal applications
HAND/AUTO CONTROL for
local and remote operation
PID CONTROL for closed loop
processes
SEQUENTIAL CONTROL for
repetitive cycles
TORQUE CONTROL for processes
where torque control is required
USER MACRO 1 & 2 for users
own parameter settings

18

3AFE 64572504 REV E EN 17.10.2003

Software features
A complete set of standard software
features offers premium functionality and flexibility.
Accurate speed control
Accurate torque control without
speed feedback
Adaptive Programming
Automatic reset
Automatic start
Constant speeds
Controlled torque at zero speed
DC hold
DC Magnetizing
Diagnostics
Flux braking
Flux optimization
IR compensation
Master/follower control
Mechanical brake control
Motor identification
Parameter lock
Power loss ride-through
Process PID control
Programmable I/O
Scalar control
Speed controller tuning
Start-up Assistant
Trim function
User-selectable acceleration and
decelaration ramps

Pre-programmed protection
functions
A wide feature range provides
protection for the drive, motor and
the process.
Ambient temperature
DC overvoltage
DC undervoltage
Drive temperature
Input phase loss
Overcurrent
Power limits
Short circuit

Programmable protection
functions

Adjustable power limits


Control signal supervision
Critical frequencies lock-out
Current and torque limits
Earth fault protection
External fault
Motor phase loss
Motor stall protection
Motor thermal protection
Motor underload protection
Panel loss

Start-up Assistant
The easy way of commissioning.
L <- 0.0 rpm
0
** INFORMATION **
Press FUNC to start
guided motor set up

Basic set up
LANGUAGE ?
[ENGLISH]
Select(arrows)+ENTER

Motor set up
MOTOR NOM CURRENT ?
0A
Press FUNC for info

READY
READY TO
TO START
START

ABB AC drives have always been


top of their class in user- friendliness. The new ACS800 AC drive
brings a whole new meaning to
user-friendliness. Thanks to the
Start-up Assistant, the commissioning and tuning of a high
performance drive could not be
easier.

Faster and easier


commissioning
When you turn on your drive for
the first time the Start-up Assistant
actively guides you through the
commissioning procedure. You do
not need to worry which parameters should be set, the Start-up
Assistant does that.

All this saves your time enabling


you to concentrate on essential
issues.

On-line info system


To make it easier and more informative, there is an on-line info
system available at each step
helping to set the correct values for
each parameter. Just one push of
the button and useful hints and
information for that specific stage
are available to you.

Features
Easy and fast commissioning
procedure
Intelligent guide to assist you
through the commissioning
Your own language
On-line info system always
available
The ACS800 offers you all this as a
standard feature.

Each step also includes reference to


the printed manuals if even more
specific information is needed.

To ensure a convenient commissioning procedure the Start-up


Assistant speaks 14 different languages. It asks for motor nominal
values as well as the I/O configuration and application specific
parameters like acceleration and
deceleration times. After this, the
ACS800 is ready for your process.

3AFE 64572504 REV E EN 17.10.2003

19

Adaptive Programming
No extra hardware or software needed.

The freely programmable I/O and


the extensive parameter selections
make the ACS800 highly suitable as
such for most applications. The
ACS800, however, goes one step
further with the addition of Adaptive
Programming as a standard feature.
It is like having a small PLC inside
your drive. Adaptive Programming
needs no additional hardware or
software but is always there when
needed.

Programming done in a few


minutes
Adaptive Programming consists of a
set of blocks, which can be programmed to perform any of the
predefined set of functions. All the
common functions for making a real
block program are available to you.
The user can freely define inputs to
the blocks, wiring between the
blocks and connections to the drive
I/O or to the drive control. In this
way the user is able to create new
input and/or output signals and
modify the drives speed or torque
control.

20

3AFE 64572504 REV E EN 17.10.2003

Programming the new ACS800 could


not be any easier. All you need is
the control panel and the programming is as simple as setting
parameters. With Adaptive Programming the user is really able to modify
the new ACS800 to suit the process
perfectly.
Because no extra hardware or
software is needed, the programming can be done in a few minutes
even on-site.

Optimal adaptability
Small PLC inside
Program your drive on-site during
commissioning
Create your own I/O signals,
modify speed or torque reference
chain or set a timer
Do it without any additional
hardware or software
As simple as setting a parameter
There is also a PC tool available for
Adaptive Programming.

Features
15 programmable function blocks
Available functions:
Logical: AND, OR and XOR
Mathematical: add, mul, div,
abs, max and min
Other: timer, switch, comparator,
filter, SR, PI and user defined
warnings or faults
Freely definable execution order
Easy documentation
The ACS800 offers you all this as a
standard feature!

Control Solutions
ABBs ready-made Control Solutions for specific drive applications.

Centrifuge Control
Practical programmable sequences
for conventional centrifuges. Decanter Control for accurate speed
difference control of two shafts.

Spinning Control & Traverse


Control

The main advantages of


ABBs control solutions:

Spinning Control and Traverse


Control make a perfect pair for
precise control of spinning and
traverse drives in textile machines.

Extruder Control
High starting torque, accurate
speed/torque control and overload
protection for demanding extruder
applications.

Crane Drive Control


The cost effective crane drive with
optimal operational safety and
outstanding performance already
built in.

Application-dedicated features
Improved production
No external PLC
User-friendly
Easy to use
Energy savings
Smooth power loss ridethrough
Reduced costs
Adaptive protections

Pump and Fan Control


Pump and Fan Control provides
better flow control and cost savings up to 5 parallel motors in
various industrial pump and fan
applications.

Master/Follower Control
Reliable control via fibre optic link
of several drives when motor shafts
are coupled together.

3AFE 64572504 REV E EN 17.10.2003

21

Control Solutions
Centrifuge Control.

Centrifuge Control features


Centrifugation patterns
Common DC-link possibility

Additional Decanter Control


features

Centrifuge &
Decanter Centrifuge as one
The Centrifuge application consists
of programmable sequences for
centrifuges e.g. in the food and
beverage industries. The Decanter
Control is integrated with the
Centrifuge Control. This feature can
be applied in all applications
needing co-ordinated speed difference control.

A decanter (separator, centrifuge) is


used to separate solid particles from
fluid. In a typical decanter two
rotating shafts called bowl and
scroll are used. Direct Torque
Control enables smooth operation
with different kinds of fluid viscosity
and automatically adapts to load
changes.

Control Solutions
Extruder Control.
AC drives designed for
extruder applications
An extruder is an application where
material typically in granulate or
pulverized form is driven through a
screw to achieve a continuous
material form to be further modified
in the manufacturing process. Due
to the material characteristics high
starting torque is often needed. The
screw and also the delicate mechanical parts of the machinery
need to be protected against overload.

22

3AFE 64572504 REV E EN 17.10.2003

Extruder application
features
High starting torque, excellent
speed accuracy without encoder
Adaptive torque limitation feature
Two sets of parameterised stall
protection functions
Digital potentiometer with two
different accelerating and
decelerating ramp times
Four control locations

Direct communication between


bowl and scroll drive through
optical fibres
Automatic scaling of process
speed based on the given gear
box and belt ratio
Speed difference control
Load compensation of scroll
drive

Control Solutions
Pump and Fan Control.

Introduction
There are many pump and fan
installations with quite extensive
flow variations. Such are water and
sewage systems, air conditioning,
district heating and different industrial applications. A common
solution for these is to run several
fixed speed pumps or fans in
parallel and flow control is made by
switching them on and off. This

Mains 400 V/50 Hz

kind of control causes discontinuous flow and there is a risk of


damage caused by pressure strokes.
Better flow control can be achieved
with variable speed drives. The cost
can be reduced by putting a variable speed drive to one unit only
and controlling the fixed speed
units with the Pump and Fan
Control application, PFC.

Alternation
switchgear
cabinet

Pressure
transducer
0...10 bar
4...20 mA

M1
7.5 kW
1450 rpm
14.8 A

Features
The maximum number of units
(pumps or fans) in parallel is 5
(1 with speed control and 4 with
fixed speed)
PI controller with
setpoint adjustment internal or
external
actual value with five selectable
units
Setpoint steps for 4 motors
Sleep and wake up level and
delay settings
Start and low frequency settings
for 4 motors
Start and stop delays
Autochange delay and level
settings
Automatic interlocking between
motors

M2
7.5 kW
1450 rpm
14.8 A

Pumping station for two pumps. ACS800 is installed inside the


alternation switchgear cabinet.

3AFE 64572504 REV E EN 17.10.2003

23

Control Solutions
Spinning Control & Traverse Control.

ACS800 Spinning Control is a


solution for the precise control of
spinning machine and for preventing yarn breakages. The ACS800
drive features allow maximum
production and prevent yarn
breakages during start-up and any
power losses.
The Traverse Control is designed to
run traverse drives guiding yarn into
a package in textile machines. To
avoid layering at the reversal points
of the yarn guide an instantaneous
change, a P-jump, is made at speed.

ACS800
Spinning Control

Speed
Time
Pattern

Yarn
Bobbin

Doff

Motor

Gear

The principle of the Spinning Control.

ACS800
Traverse Control

ACS800 with
Standard program

P-jump
function

Features for Spinning


Control:

Wobbulation function
Shiftwise production calculation
Automatic doff (pattern) selection
4 speed time patterns

Features for Traverse


Control:
Wide selection for base speed
reference
Dynamic quick steps, real or
proportional steps

24

Yarn package

3AFE 64572504 REV E EN 17.10.2003

Gear
Motor
Yarn guide

Yarn

Gear
Motor

The principle of the Traverse Control.

Control Solutions
Crane Drive Control.

Standard ready-to-use crane drive


solution with optimal operational
safety and outstanding crane drive
performance.

Crane Drive Control


The cost-effective crane drive with
safety and performance already
built in.
Easy installation and start-up
reduces the total project costs
Ready to use with proven
modular crane functionality
Accurate and fast torque response
increases the operational
productivity
Smooth crane operation reduces
maintenance and damage costs
Available as single drive and
multi drive with dynamic and
regenerative braking

Flexible user interface

Outstanding performance

Joystick interface, with step or


continuous speed reference
Pendant control, with built in
motor potentiometer
Radio control, with step or
continuous speed reference
Fieldbus communication, for
connection to PLC
Limit switches, to ensure the
crane works within a safe
operation area

Start and stop logic ensures that


torque is available before the
brake is released
4 different ramp times. Individual
settings for acceleration and
deceleration ramp times in both
directions
Torque memory presets torque
when starting the hoist with
suspended load, used for
avoiding load drops when
mechanical brake is released
Power optimization ensures
maximum hoist speed relative to
the load. This optimizes the
cranes capacity
Optical master-follower link,
used for load sharing between
two mechanically connected
motors. This can also be used for
redundancy applications
Electrical shaft function, for
synchronizing two drives without
mechanical connection.
Adjustable control for position
correction

Operational safety
Mechanical brake functions for
controlling and supervising the
brake
Adjustable fast stop procedure in
case of overload or slack rope
etc.
Torque proving ensures that the
motor has produced sufficient
torque when opening the brakes
Speed monitoring ensures that
the speed stays within given
limits. Also zero speed detection
Torque monitoring supervises the
correlation between the speed
ordered and actual motor speed

3AFE 64572504 REV E EN 17.10.2003

25

ACS800 I/O

Analog and digital I/O channels are


used for different functions such as
control, monitoring and measurement
purposes (e.g. motor temperature).

In addition, optional I/O extension


modules are available providing
additional analog or digital connections.

Standard I/O on RMIO-01 Board


3 analog inputs: differential, common mode voltage,
galvanically isolated as a group.
- One 0(2)...10 V, resolution 12 bit
- Two 0(4)...20 mA, resolution 12 bit
2 analog outputs:
- 0(4)...20 mA, resolution 10 bit

X20
1
2
X21
1

VREF- Reference voltage -10 VDC, 1 kohm < RL <


AGND 10 kohm

VREF+ Reference voltage 10 VDC, 1 kohm


AGND < RL < 10 kohm

7 digital inputs: galvanically isolated as a group


(can be split in two groups)
- Input voltage 24 V
- Filtering (HW) time 1 ms

AI1+

4
5

AI1-

AI2AI3+

3 relay (digital) outputs:


- Switchover contact
- 24 V or 115/230 V AC
- Max. 2 A
Reference voltage output:
- 10 V 0.5%, max. 10 mA
Auxiliary power output:
- +24 V 10%, max. 250 mA

8
9

AI3-

10

AO1AO2+

Optional I/O
Analog I/O Extension Module RAIO-01
2 analog inputs: galvanically isolated from 24 V supply
and ground
- 0(2)...10 V, 0(4)... 20 mA or 0...2 V, resolution 12 bits
2 analog outputs: galvanically isolated from 24 V supply
and ground
- 0(4)...20 mA, resolution 12 bit

7
rpm

AI2+

AO1+

By default, not in use. 0(4) ... 20 mA,


Rin = 100 ohm
By default, not in use. 0(4) ... 20 mA,
Rin = 100 ohm
^ 0...motor
Motor speed 0(4)...20 mA =
nom. speed, RL < 700 ohm

AO2-

^ 0...motor
Output current 0(4)...20 mA =
nom. current, RL < 700 ohm

DI1
DI2

Stop/Start
Forward/Reverse

3
4

DI3

5
6

DI5
DI6

By default, not in use.


Acceleration & deceleration select
Constant speed select
Constant speed select

7
8

+24VD +24 V DC max. 100 mA


+24VD

DGND1 Digital ground


DGND2 Digital ground
Start interlock (0 = stop)
DIIL

10
11
X23

DI4

3 digital inputs: individually galvanically isolated


- Signal level 24 to 250 V or 115/230 V AC
2 relay (digital) outputs:
- Switchover contact
- 24 V or 115/230 V AC
- Max. 2 A

+24V
GND

X25
1

RO11

Pulse Encoder Interface Module RTAC-01

1 incremental encoder input:


- Channels A, B and Z (zero pulse)
- Signal level and power supply for the encoder is 24 or 15 V
- Single ended or differential inputs
- Maximum input frequency 200 kHz

RO22
RO23

X27
1

RO31

3AFE 64572504 REV E EN 17.10.2003

Speed reference 0(2) ... 10 V, Rin >


200 kohm

12
X22

11

Digital I/O Extension Module RDIO-01

26

Below are the standard control connections of the ACS800 single drive
with Factory Macro. For other ACS800
application macros the functions
may be different.

RO12
RO13

X26
1

RO21

2
3

RO32
RO33

Auxiliary voltage output, non-isolated,


24 V DC 250 mA
Relay output 1: ready

Relay output 2: running

Relay output 3: fault (-1)

Control Panel
ACS800 with user-friendly functionality.

Fault memory

A built-in fault memory


stores information relating
to the latest 64 faults, each
with a time stamp.

The ACS800 control panel provides


a great deal of information in plain,
easy-to-understand language.

Actual value
The ACS800 control panel can
display three separate actual values
simultaneously.
Examples of these are:
Motor speed
Frequency
Current
Torque
Power
References
DC bus voltage
Output voltage
Heatsink temperature
Operating hours
Kilowatt hours

Parameter copying

Parameter copy feature


allows all drive parameters
to be copied from one
frequency converter to
another to simplify
commissioning.

Centralised
control

One panel can


control up to 31
drives.

Simple
arrangement

Parameters are
organised into
groups for easy
programming.

Control Panel
Multilingual alphanumeric display
(4 lines x 20 characters) plain text
messages in 14 languages.
Intelligent removable control panel
can be mounted on the ACS800
enclosure or remotely.

Local drive operation from control


panel, including LOCAL/REMOTE
selection, START/STOP, RESET,
MOTOR ROTATION DIRECTION
and REFERENCE setting.

Start-up Assistant

Easy commissioning with


the Start-up Assistant.
The Start-up Assistant
actively guides you through
the commissioning procedure.
Adaptive Programming

No extra hardware or
software required for
Adaptive Programming.

3AFE 64572504 REV E EN 17.10.2003

27

Fieldbus Control
Gateway to your process.

ABB AC drives have the connectivity to major automation systems.


This is achieved with a dedicated
gateway concept between the
fieldbus systems and ABB drives.
The fieldbus gateway is a snap-on
module that can be easily mounted
inside the drive. As a result of the
wide range of fieldbus gateways,
your choice for an automation
system becomes independent of
your decision to use first-class ABB
AC drives.

Manufacturing Flexibility
Drive control
The drive Control Word (16 bit)
provides a wide variety of functions
from Start, Stop and Reset to Ramp
Generator control. Typical setpoint
values like Speed, Torque and
Position can be transmitted to the
drive with 15 bit accuracy.
Drive monitoring
A set of drive parameters and/or
actual signals, like torque, speed,
position, current etc., can be selected for cyclic data transfer
providing fast data for operators
and the manufacturing process.

28

3AFE 64572504 REV E EN 17.10.2003

Drive diagnostics
Accurate and reliable diagnostic
information can be obtained via the
drive Alarm, Limit and Fault Words
reducing the down time of the drive
and therefore also the down time of
the manufacturing process.

Reduced Installation and


Engineering Effort

Drive parameter handling


Total integration of the drives in the
production process is achieved by
single parameter read/write up to
complete parameter set-up or
download.

Design
The use of Fieldbus Control reduces
engineering time at installation due
to the modular structure of the
hardware and software.

Easy to expand
Serial communication simplifies the
latest trend of modular machine
design enabling expansion of the
installation at a later stage with low
effort.

Cabling
Substituting the large amount of
conventional Drive Control cabling
with a single twisted pair reduces
costs and increases system reliability.

Commissioning and assembly


The modular machine configuration
allows pre-commissioning of single
machine sections and provides easy
and fast assembly of the complete
installation.

Currently Available Gateways

PROFIBUS-DP
DeviceNet
CANopen
ControlNet
ModbusPlus
LONWORKS
Modbus
Ethernet
InterBus-S

Dynamic Braking
Brake Choppers and Resistors.
Brake Chopper

and detects failures such as brake


resistor and resistor cable short
circuits, chopper short circuit, and
calculated resistor overtemperature.

The ACS800 series has in-built


brake choppers for all types.
Therefore, no additional space or
installation time is needed. The
brake chopper is part of the standard delivery for the R2 and R3
frames. For the other frames a
brake chopper is a selectable
option.

For ACS800 units, no separate fuses


in the brake circuit are required if
the following conditions are met:
The ACS800 mains cable is
protected with fuses
No mains cable/fuse overrating
takes place

Brake Resistor
The SACE/SAFUR brake resistors
are separately available for all
ACS800 types. Resistors other than
the standard resistors may be used
providing the specified resistance
value is not decreased, and the heat
dissipation capacity of the resistor is
sufficient for the drive application.

Braking control is integrated into


the ACS800 series. It controls the
braking, supervises the system status

UN = 230 V (208, 220, 230, 240 V)


ACS800 type

ACS800-01-0001-2
ACS800-01-0002-2
ACS800-01-0003-2
ACS800-01-0004-2
ACS800-01-0005-2
ACS800-01-0006-2
ACS800-01-0009-2
ACS800-01-0011-2
ACS800-01-0016-2
ACS800-01-0020-2
ACS800-01-0025-2
ACS800-01-0030-2
ACS800-01-0040-2
ACS800-01-0050-2
ACS800-01-0060-2
ACS800-01-0070-2

Brake Chopper
Power

Brake Resistor(s)

ACS800 type

Continuous
Pbrcont [kW]

Type

R
[Ohm]

Er
[kJ]

P rcont
[kW]

0.6
0.8
1.1
1.5
2.2
3
4
5.5
11
17
23
28
33
45
56
68

SACE08RE44
SACE08RE44
SACE08RE44
SACE08RE44
SACE15RE22
SACE15RE22
SACE15RE22
SACE15RE13
SAFUR90F575
SAFUR90F575
SAFUR80F500
SAFUR125F500
SAFUR125F500
2 x SAFUR125F500
2 x SAFUR125F500
2 x SAFUR125F500

44
44
44
44
22
22
22
13
8
8
6
4
4
2
2
2

248
248
248
248
496
496
496
496
1800
1800
2400
3600
3600
7200
7200
7200

1
1
1
1
2
2
2
2
4.5
4.5
6
9
9
18
18
18

Brake Chopper Power

Brake Resistor(s)

5 / 60 s 10 / 60 s 30/60 s Continuous
Pbr5 [kW] Pbr10 [kW] Pbr30 [kW] Pbrcont [kW]
ACS800-02/04-0080-2
ACS800-02/04-0100-2
ACS800-02/04-0120-2
ACS800-02/04-0140-2
ACS800-02/04-0170-2
ACS800-02/04-0210-2
ACS800-02/04-0230-2
ACS800-02/04-0260-2
ACS800-02/04-0300-2

68
83
105
135
135
165
165
223
223

68
83
67
135
135
165
165
170
170

68
83
60
135
135
165
165
125
125

54
54
40
84
84
98
113
64
64

Type

R
[Ohm]

Er
[kJ]

P rcont
[kW]

SAFUR 160F380
SAFUR 160F380
2xSAFUR200F500
2xSAFUR160F380
2xSAFUR160F380
2xSAFUR160F380
2xSAFUR160F380
4xSAFUR160F380
4xSAFUR160F380

1.78
1.78
1.35
0.89
0.89
0.89
0.89
0.45
0.45

3600
3600
10800
7200
7200
7200
7200
14400
14400

9
9
27
18
18
18
18
36
36

UN = 400 V (380, 400, 415 V)


ACS800 type

ACS800-01-0003-3
ACS800-01-0004-3
ACS800-01-0005-3
ACS800-01-0006-3
ACS800-01-0009-3
ACS800-01-0011-3
ACS800-01-0016-3
ACS800-01-0020-3
ACS800-01-0025-3
ACS800-01-0030-3
ACS800-01-0040-3
ACS800-01-0050-3
ACS800-01-0060-3
ACS800-01/07-0070-3
ACS800-01/07-0100-3
ACS800-01/07-0120-3

Brake Chopper
Power

Brake Resistor(s)

ACS800 type

Continuous
Pbrcont [kW]

Type

R
[Ohm]

Er
[kJ]

P rcont
[kW]

1.1
1.5
2.2
3
4
5.5
7.5
11
23
28
33
45
56
68
83
113

SACE08RE44
SACE08RE44
SACE08RE44
SACE08RE44
SACE08RE44
SACE15RE22
SACE15RE22
SACE15RE22
SACE15RE13
SACE15RE13
SAFUR90F575
SAFUR90F575
SAFUR90F575
SAFUR80F500
SAFUR125F500
SAFUR125F500

44
44
44
44
44
22
22
22
13
13
8
8
8
6
4
4

248
248
248
248
248
496
496
496
496
496
1800
1800
1800
2400
3600
3600

1
1
1
1
1
2
2
2
2
2
4.5
4.5
4.5
6
9
9

Brake Chopper Power

Brake Resistor(s)

5 / 60 s 10 / 60 s 30/60 s Continuous
Pbr5 [kW] Pbr10 [kW] Pbr30 [kW] Pbrcont [kW]
ACS800-02/04/07-0140-3
ACS800-02/04/07-0170-3
ACS800-02/04/07-0210-3
ACS800-02/04/07-0260-3
ACS800-02/04/07-0320-3
ACS800-02/04/07-0400-3
ACS800-02/04/07-0440-3
ACS800-02/04/07-0490-3

135
165
165
240
300
375
473
500

135
150
150
240
300
375
355
355

100
100
100
240
300
273
237
237

80
80
80
173
143
130
120
120

Type

R
[Ohm]

Er
[kJ]

P rcont
[kW]

SAFUR200F500
SAFUR200F500
SAFUR200F500
2XSAFUR210F575
2xSAFUR200F500
4xSAFUR125F500
4xSAFUR210F575
4xSAFUR210F575

2.70
2.70
2.70
1.70
1.35
1.00
0.85
0.85

5400
5400
5400
8400
10800
14400
16800
16800

13.5
13.5
13.5
21
27
36
42
42

3AFE 64572504 REV E EN 17.10.2003

29

UN = 500 V (380, 400, 415, 440, 460, 480 and 500 V)


ACS800 type

ACS800-01-0004-5
ACS800-01-0005-5
ACS800-01-0006-5
ACS800-01-0009-5
ACS800-01-0011-5
ACS800-01-0016-5
ACS800-01-0020-5
ACS800-01-0025-5
ACS800-01-0030-5
ACS800-01-0040-5
ACS800-01-0050-5
ACS800-01-0060-5
ACS800-01-0070-5
ACS800-01/07-0100-5
ACS800-01/07-0120-5
ACS800-01/07-0140-5

Brake Chopper
Power

Brake Resistor(s)

ACS800 type

Continuous
Pbrcont [kW]

Type

R
[Ohm]

Er
[kJ]

P rcont
[kW]

1.5
2.2
3
4
5.5
7.5
11
15
28
33
45
56
68
83
113
135

SACE08RE44
SACE08RE44
SACE08RE44
SACE08RE44
SACE08RE44
SACE15RE22
SACE15RE22
SACE15RE22
SACE15RE13
SACE15RE13
SAFUR90F575
SAFUR90F575
SAFUR90F575
SAFUR125F500
SAFUR125F500
SAFUR125F500

44
44
44
44
44
22
22
22
13
13
8
8
8
4
4
4

248
248
248
248
248
496
496
496
496
496
1800
1800
1800
3600
3600
3600

1
1
1
1
1
2
2
2
2
2
4.5
4.5
4.5
9
9
9

Brake Chopper Power

Brake Resistor(s)

5 / 60 s 10 / 60 s 30/60 s Continuous
Pbr5 [kW] Pbr10 [kW] Pbr30 [kW] Pbrcont [kW]
ACS800-02/04/07-0170-5
ACS800-02/04/07-0210-5
ACS800-02/04/07-0260-5
ACS800-02/04/07-0320-5
ACS800-02/04/07-0400-5
ACS800-02/04/07-0440-5
ACS800-02/04/07-0490-5
ACS800-02/04/07-0550-5
ACS800-02/04/07-0610-5

165
198
198 1)
300
375
473
480
600
600 3)

132 2)
132 2)
132 2)
300
375
473
480
400 4)
400 4)

120
120
120
300
375
450
470
300
300

80
80
80
300
234
195
210
170
170

Type

R
[Ohm]

Er
[kJ]

P rcont
[kW]

SAFUR200F500
SAFUR200F500
SAFUR200F500
2xSAFUR125F500
2XSAFUR210F575
2xSAFUR200F500
2xSAFUR200F500
4xSAFUR125F500
4xSAFUR125F500

2.70
2.70
2.70
2.00
1.70
1.35
1.35
1.00
1.00

5400
5400
5400
7200
8400
10800
10800
14400
14400

13.5
13.5
13.5
18
21
27
27
36
36

UN = 690 V (525, 575, 600, 660 and 690 V)


ACS800 type

ACS800-01-0011-7
ACS800-01-0016-7
ACS800-01-0020-7
ACS800-01-0025-7
ACS800-01-0030-7
ACS800-01-0040-7
ACS800-01-0050-7
ACS800-01-0060-7
ACS800-01/07-0070-7
ACS800-01/07-0100-7
ACS800-01/07-0120-7

Brake Chopper
Power

Brake Resistor(s)

Continuous
Pbrcont [kW]

Type

R
[Ohm]

Er
[kJ]

P rcont
[kW]

5.5
7.5
11
15
18.5
22
30
37
45
55
75

SACE08RE44
SACE08RE44
SACE08RE44
SACE15RE22
SACE15RE13
SACE15RE13
SACE15RE13
SACE15RE13
SAFUR90F575
SAFUR90F575
SAFUR90F575

44
44
44
22
13
13
13
13
8
8
8

248
248
248
496
496
496
496
496
1800
1800
1800

1
1
1
2
2
2
2
2
4.5
4.5
4.5

Maximum braking power of the ACS800 equipped


with the standard chopper and the standard resistor.
P br5 = 5 s/ 1 min.
P br10 = 10 s/ 1 min.
P br30 = 30 s/ 1 min.
The drive and the chopper will withstand this
braking power for 5/10/30 seconds every one
minute. Note: The braking energy transmitted
to the resistor during any period shorter than
400 seconds may not exceed Er . (Er varies
depending on the resistor).
Pbrcont = Continuous brake chopper power. The value
applies to the minimum resistance value. With a
higher resistance value the Pbrcont may increase
in some ACS800-02/04/07 units.
R
= Resistance value for the listed resistor type.
Note: This is also the minimum allowable
resistance value for the brake resistor.
Er
= Energy pulse that the resistor assembly will
withstand (400 s duty cycle). This energy will
heat the resistor element from 40C to the
maximum allowable temperature.
Prcont = Continuous power (heat) dissipation of the
resistor when placed correctly. Energy Er
dissipates in 400 seconds.

30

ACS800 type

3AFE 64572504 REV E EN 17.10.2003

Brake Chopper Power

Brake Resistor(s)

5 / 60 s 10 / 60 s
30/60 s Continuous
Pbr5 [kW] Pbr10 [kW] Pbr30 [kW] Pbrcont [kW]
ACS800-04/07-0140-7
ACS800-04/07-0170-7
ACS800-04/07-0210-7
ACS800-04/07-0260-7
ACS800-04/07-0320-7
ACS800-04/07-0400-7
ACS800-04/07-0440-7
ACS800-04/07-0490-7
ACS800-04/07-0550-7
ACS800-04/07-0610-7

125 5)
125 6)
125 6)
135 7)
300
375
430
550
550
550

1)

240 kW possible if Ambient below 33C

2)

160 kW possible if Ambient below 33C

3)

630 kW possible if Ambient below 33C

4)

450 kW possible if Ambient below 33C

5)

135 kW possible if Ambient below 33C

6)

148 kW possible if Ambient below 33C

7)

160 kW possible if Ambient below 33C

110
110
110
120
300
375
430
400
400
400

All brake resistors are to be installed outside the


converter module.
The SACE brake resistors are built in an IP 21 metal
housing.
The SAFUR brake resistors are built in an IP 00 metal
frame.

90
90
90
100
300
375
430
315
315
315

75
75
75
80
260
375
385
225
225
225

Brake Resistor
SACE08RE44
SACE15RE22
SACE15RE13
SAFUR80F500
SAFUR90F575
SAFUR180F460
SAFUR125F500
SAFUR200F500
SAFUR210F575

Type

R
[Ohm]

Er
[kJ]

P rcont
[kW]

SAFUR80F500
SAFUR80F500
SAFUR80F500
SAFUR80F500
SAFUR200F500
SAFUR200F500
SAFUR200F500
2xSAFUR125F500
2xSAFUR125F500
2xSAFUR125F500

6.00
6.00
6.00
6.00
2.70
2.70
2.70
2.00
2.00
2.00

2400
2400
2400
2400
5400
5400
5400
7200
7200
7200

6
6
6
6
13.5
13.5
13.5
18
18
18

Height
mm
365
365
365
600
600
1320
1320
1320
1320

Width
mm
290
290
290
300
300
300
300
300
300

Depth Weight
mm
kg
131
6.1
131
6.1
131
6.8
345
14
345
12
345
32
345
25
345
30
345
27

Output filters
Factory installed and external filters.

As with all frequency converters


employing the most modern IGBT
inverter technology, the ACS800
output comprises - regardless of
output frequency - pulses of approximately 1.35 times the mains
network voltage with a very short
rise time. The voltage can be almost
double at the motor terminals,
depending on motor cable properties.

Du/dt filtering suppresses inverter


output voltage spikes and rapid
voltage changes that stress motor
insulation. Additionally, du/dt
filtering reduces capacitive leakage
currents and high frequency emission of the motor cable as well as
high frequency losses and bearing
currents in the motor.
When to Use? The need of du/dt
filtering depends on the motor
insulation. For information on the

construction of the motor insulation, consult its manufacturer. If the


motor does not fulfil the following
requirements, the lifetime of the
motor might shorten.
Additionally insulated N-end (nondriven end) bearings and / or
common mode filters are required
to motor bearing currents with
motors bigger than 100 kW. For
more information see ACS800
hardware manuals.

Filter selection table for ACS800


Motor type
ABB M2 and
M3 motors
ABB form-wound
HXR and AM motors
ABB random-wound
HXR and AM motors
Non-ABB
Random-wound

Nominal mains
voltage (UN)
UN 500 V
500 V < UN 600 V
600 V < UN 690 V
380 V < UN 690 V
380 V < UN 690 V
UN 420 V
420 V < UN 500 V
500 V < UN 600 V

600 V < UN 690 V


Non-ABB Form-wound 600 V < UN 690 V

Symbol
UN
LL
t

Motor insulation requirement


Standard insulation system.
Standard insulation system in conjunction with du/dt filtering or reinforced insulation.
Reinforced insulation system in conjunction with du/dt filtering.
Standard insulation system.
Check motor insulation system with the motor manufacturer.
du/dt filtering with voltages over 500 V.
Insulation system must withstand LL=1300 V.
If the insulation system withstands LL =1600 V and t=0.2 s, du/dt filtering is
not required. With du/dt filtering, the insulation system must withstand LL=1300 V.
If the insulation system withstands LL =1800 V, du/dt filtering is not required.
With du/dt filtering, the insulation system must withstand LL=1600 V.
If the motor insulation system withstands LL=1800 V, du/dt filtering is not required.
If the motor insulation system withstands LL =2000 V and t=0.3 s,
du/dt filtering is not required.

Explanation
Nominal mains voltage.
Peak line to line voltage at motor terminals.
Rise time, i.e. interval during which line to line voltage at motor terminals changes from 10% to 90% of full
voltage range.

3AFE 64572504 REV E EN 17.10.2003

31

External du/dt filters for ACS800-01 and ACS800-04


du/dt filter type (3 filters included in kits marked *)

Applicability
Factory-installed du/dt filters are
available for ACS800-07/-17. They
are installed inside the converter
cubicle. The filters are also separately available for other ACS800
types.
Then they need to be mounted
externally. Unprotected (IP 00)
filters must be encased.

-0004-5
-0005-5
-0006-5
-0009-5
-0011-5 -0011-7
-0016-5
-0016-3 -0020-5 -0016-7
-0020-3
-0020-7
-0025-7
-0025-3 -0025-5 -0030-7
-0030-3 -0030-5 -0040-7
-0040-3 -0040-5 -0050-7
-0050-3 -0050-5 -0060-7
-0060-5
-0060-3 -0070-5 -0070-7
-0070-3 -0100-5 -0100-7
-0120-7
-0100-3 -0120-5
-0120-3 -0140-5
-0140-3 -0170-5 -0140-7
-0170-3 -0210-5 -0170-7
-0210-3 -0260-5 -0210-7
-0260-3 -0320-5 -0260-7
-0320-3 -0400-5 -0320-7
-0400-7
-0400-3 -0440-5 -0440-7
-0440-3 -0490-5 -0490-7
-0490-3 -0550-5 -0550-7
-0610-5 -0610-7

3AFE 64572504 REV E EN 17.10.2003

1
1
1
2

Height
mm

Width
mm

Depth
mm

Weight
kg

NOCH0016-60

195

140

115

2.4

NOCH0016-62/65

323

199

154

NOCH0030-60

215

165

130

4.7

NOCH0030-62/65

348

249

172

NOCH0070-60

261

180

150

9.5
15.5

NOCH0070-62/65

433

279

202

NOCH0120-60**

200

154

106

NOCH0120-62/65

765

308

256

45

AOCH0260-70**

190

340

242

15.9

AOCH0400-70**

190

340

257

20.7

NOCH0120-65

NOCH0070-65

NOCH0030-65

NOCH0016-65

NOCH0120-62

NOCH0070-62

** 3 filters included, dimensions apply for one filter.

32

NOCH0030-62

Dimensions and Weights of the


du/dt filters
du/dt filter

NOCH0016-62

*AOCH0400-70

*AOCH0260-70

*NOCH0260-60

*NOCH0120-60

690 V

NOCH0070-60

500 V

NOCH0030-60

400 V
-0003-3
-0004-3
-0005-3
-0006-3
-0009-3
-0011-3

NOCH0016-60

ACS800

Protected
to IP 54

Protected
to IP 22

Unprotected (IP 00)

Programming Tool
DriveAP for Adaptive Programming.

Easy to use PC tool

Upload or download

DriveAP is a PC tool to create,


document, edit and download
Adaptive Programs. Adaptive
Programming can be done with the
standard control panel or with
DriveAP. DriveAP offers a clear and
easy way to develop, test and
document Adaptive Programs with
a PC.

Adaptive Programs can be uploaded


from connected drives and displayed
graphically on a PC screen e.g. for
service or documentation purposes.
Ready made Adaptive Programs can
be downloaded to any of the
connected drives.

Three operating modes


DriveAP is a user-friendly tool to
modify function blocks and their
connections. No special programming skills are required. Basic
knowledge about block programming is enough.
Adaptive Programming results are
easy to document as hard copies or
store as PC files with DriveAP.

Stand Alone Mode - DriveAP


is not connected to a drive.
Adaptive Programming can be
carried out e.g. in the office and
downloaded later on
Off-Line Mode - DriveAP is
connected to a drive. Adaptive
Programming is carried out in
batch mode
On-Line Mode - DriveAP is
connected to a drive. Changes
to the program are written
immediately to the drive and
actual values are shown on the
screen in real time

Features
Easy to use tool, no special skills
required
Create and download new
programs
Document your programs
Upload existing programs from
the drive
Operating modes
Stand Alone
Off-Line
On-Line

DriveAP is part of the DriveIT folder


of the IndustrialIT.

3AFE 64572504 REV E EN 17.10.2003

33

Integration Tool
DriveOPC for Windows based monitoring.

DriveOPC
DriveOPC is a software package
which allows OLE for Process
Control (OPC) communication
between Windows applications and
ABB drives. It is an ideal tool for
integrating commercial PC monitoring software and ABB drives.
DriveOPC can access all drives
connected to the fast optical link
of the drives. The number of
measuring points is unlimited.

OPC based software


OPC stands for Ole for Process
Control, an open architecture
interface design defined by the
international OPC Task Force. It is
an open interface for Factory
Automation.

Remote monitoring
DriveOPC enables remote connection over LAN (local area
networks). The remote PC can be
connected by its IP address (e.g.
"164.12.43.33") or by the DNS name
(e.g. "Gitas213").

34

3AFE 64572504 REV E EN 17.10.2003

Read access to:


Drive status: local, running,
direction, fault, warning, homing,
reference
Signals and parameters
Fault logger contents
Event logger contents
General drive information
Data logger settings, status and
contents
Write access to:
Drive Control: local, start, stop,
forward, reverse, coast stop, reset
fault, home, teach-in, contactoron/off, reference
Parameters
Fault logger clear
Data logger init, start, trig, clear
DriveOPC is part of the DriveIT
folder of the IndustrialIT.

Features:
To control and monitor with PCbased process control software
Standard interface
Remote connection over LAN
(local area networks)
Access to
Drive control
Signals and parameters
Data and Fault loggers

Engineering Tool
DriveSize for dimensioning motors and drives.

Quality dimensioning
DriveSize is a PC program for
helping the user to select an optimal motor, frequency converter and
transformer, especially in those
cases where a straightforward
selection from a catalogue is not
possible. Additionally it can be used
to compute currents, network
harmonics and to create documents
about the dimensioning based on
actual load. DriveSize contains a
current version of ABB motor and
frequency converter catalogues.
The default values make DriveSize
simple to use, but the user is provided with ample options for drive
selection. The shortcut keys make
drive selection easy while still
honouring the relatively complicated rules. A manual selection
mode is also supported.
DriveSize is currently used by more
than 1000 engineers globally.

DriveSize is for drive system


components
3-phase standard, customized,
Ex and user defined motors
ABB low voltage AC drives
ACS400
ACS600
ACS800
Transformers

DriveSize functions
The software performs dimensioning based on the following input:
Speed range and mechanical load
with overloads
Ambient temperature and
altitude
Required IP-class and allowed
temperature rise
Supply network characteristics
Load type and duty cycle
Optionally current requirements
for inverters
DC power requirement for line
supply unit
Apparent power requirement for
the transformer

Additional functions
The software also enables you to:
Calculate the network harmonics
of individual drive or set of
drives
Obtain efficiency values
See your selections in graphical
or numeric form
Select manually unit from the
database
Print out reports
Save the dimensioning results
into files

Benefits
Select an optimal motor,
frequency converter and
transformer
Dimensioning based on actual
shaft load
Documents dimensioning
results, graphical and numerical
presentation
Network harmonic and power
factor calculaton
Print out and save the results

3AFE 64572504 REV E EN 17.10.2003

35

Start-up and Maintenance Tool


DriveWindow 2

WindowsTM -based, userfriendly


ABB's DriveWindow is an advanced, easy-to-use tool for the
commissioning and maintenance of
drive systems in different industries.
Its host of features and clear,
graphical presentation of the operation make it a valuable addition to
your system providing information
necessary for troubleshooting,
maintenance and service, as well
as training.
DriveWindow is fully 32 bit and
runs in the newer Microsoft Windows
environments. DriveWindow has
connection kits for both laptop and
desktop PCs.
With DriveWindow the user is able
to follow the co-operation of two
or more drives simultaneously by
collecting the actual values from
the drives onto a single screen or
printout.
Additionally, the client part of
DriveWindow may reside on one
Local Area Network PC, and the
server side on another PC closer to
the drives. This enables plant-wide
monitoring to be easily accomplished with two PCs.
36

3AFE 64572504 REV E EN 17.10.2003

Powerful and versatile


DriveWindow can access all
drives connected to the high
speed fiber optic network
Signal values can be viewed as
graphs from the drive/drives
A screenful of signals and
parameters from the drive can be
monitored and edited at one time
(off-line or on-line)
View data collected and stored in
the drive
Fault diagnosis; DriveWindow
indicates the status of drives, and
also reads fault history data from
the drive
Remote monitoring, plant wide
monitoring with two PCs
Back-up of drive parameters; in
fault situations the file can be
easily reloaded, resulting in time
savings
Back-up parameters or software
from the drive into PC files. This
version allows the entire control
board content to be saved and
restored later - even to empty
control boards. One empty spare
control card can function as a
spare part for many different
sizes of drives
DriveWindow is part of the DriveIT
folder of the IndustrialIT.

Features
Easy-to-use tool for
commissioning and maintenance
Several drives connected and
monitored at the same time
Monitor, edit or save signals and
parameters, clear graphical
presentation
High speed communication
between PC and drive
Versatile back-up functions

Start-up and Maintenance Tool


DriveWindow Light 2.1

Simple to use
The DriveWindow Light 2.1 is a
comprehensive commissioning and
maintenance tool for ABB drives.
This easy-to-use software is for
editing, uploading and downloading drive parameters and, for
example, monitoring the actual
values and status information of
the drive system.
DriveWindow Light 2.1 enables most
drive parameters to be set offline in
the office when uploaded from the
drive, and then saved in the drivespecific files. The files can be further
modified and downloaded to the
respective drives at the installation
site.

The configuration can then be tested


and fine-tuned using the software's
monitoring feature. The final parameter settings can be saved for
back-up purposes and also printed
out easily for customer documentation.
The DriveWindow Light 2.1 package
consists of the software tool, based
on 32-bit architecture of Microsoft
Windows environment, and the RS232/RS-485 PC connection unit kit
hardware. DriveWindow Light can
also be used for the ACS140 and
ACS400 with RS-485/232 adapter.

Practical functions
Parameter browser for editing
(online/offline) and viewing
parameter values online
Parameter compare function for
parameters in a drive and a
parameter file
Parameter back-up and restore
Easy adjustment of pointer type
parameters, e.g. Adaptive
Programming
Graphical and numerical
monitoring of signals
Control panel with step function

DriveWindow Light is part of the


DriveIT folder of the IndustrialIT.

3AFE 64572504 REV E EN 17.10.2003

37

Remote Monitoring Tool


The intelligent Ethernet module NETA-01.

Browser-based, user-friendly
The intelligent Ethernet module
gives simple access to the drive via
the Internet communicating via a
standard web browser. The user
can set up a virtual monitoring
room wherever there is a PC with
an Internet connection or via a
simple dial-up modem connection.
This enables remote monitoring,
configuration, diagnostics and,
when needed, control. The drive
can also provide process related
information, such as load level, run
time, energy consumption and I/O
data, the bearing temperature of
the driven machine, for instance.

No PC needed at local end


The intelligent Ethernet module has
an embedded server with the
necessary software for the user
interface, communication and data
storage. This gives ease of access,
real time information and the
possibility for two-way communication with the drive, enabling
immediate response and actions,
saving time and money. This is
possible without using a PC at the
local end, as required by other
remote solutions.

E-mail alerts
The module can also send condition
triggered event alerts to predefined
38

3AFE 64572504 REV E EN 17.10.2003

email addresses. This opens new


possibilities for the monitoring and
maintenance of unmanned applications across a range of industries, for
instance water, wind power, building
services and oil & gas, as well as
any decentralised application where
the user needs access to the drives
from more than one location. It also
provides an opportunity for OEMs
and system integrators to support
their installed base globally.

Powerful and versatile


Up to nine drives can be connected
to the intelligent Ethernet module via
fibre optic links. It is available as an
option for new drives, as well as an
upgrade for existing systems.
Ethernet allows the integration of
office and process environments
into a global network. The module
supports the usual HTTP, IP, TCP,
SMTP, BOOTP, UDP, Telnet and FTP
protocols, as well as Modbus/TCP
based process control. Access to the
module is secured by user ID and
passwords. Multiple security level
enables the allocation of different
access rights to normal users and
administrators. Even higher levels
of security can be achieved using a
Virtual Private Network (VPN)
connection.

The module is mounted onto a


standard mounting rail inside or
outside the drive unit, depending
on drive type and configuration. It
connects to the drive with fibre
optic cables. The size of the module
is 93 (h) x 35 (w) x 76.5 (d) mm.
The IP address of the Ethernet
module can be freely allocated. The
user interface with the drive is
created using embedded Java
applets. The web page of the
module is opened like any other
web address. The home page
shows a general overview of the
system with traffic lights and action
buttons to guide the user through
the different sections.

Features
Virtual monitoring room for
Monitoring
Configuration of parameters
Diagnostics
Control, if needed
Browser based access via
Intra-/extra-/Internet or
Simple dial-up modem
connection
E-mail alerts to predefined
addresses
No PC needed at the local end
Can be used as a Modbus/TCP
bridge for control purposes

Energy saving with ACS800


Environmental Product Declarations.
How much air pollution is caused
by an electric motor or drive? How
does the manufacture and use of
electric motors and drives affect
water quality? Or influence global
warming? These were some of the
questions ABB asked itself when it
decided to assess and improve the
environmental impact of its electric
motors and drives.
The solution was to provide Environmental Product Declarations
(EPDs) for all core ABB products.
EPDs describe the environmental
aspects and impacts of a product
line over its entire life cycle.

The EPD program aims


To enable ABB designers to assess
and improve the environmental
performance of a product over its
full life cycle
To facilitate a sound comparison
of the environmental performance
of alternative products, using
available environmental criteria
To provide ABBs customers with
LCA data of ABB products to
facilitate environmental
assessments of their processes
To promote the environmental
performance of ABB products and
services among its stakeholders
and to enhance ABBs business
The declarations are based on Life
Cycle Assessment (LCA) studies and
conform to ISO 14025.

flow control applications such as


pumps, fans and compressors.
Companies having installed AC
drives have already reaped huge
savings when mechanical control
devices such as throttling valves,
dampers or hydraulic clutches have
been replaced with electronic speed
control.
Even more energy savings are
obtainable when older AC drives
are replaced by ABB AC drives. The
additional energy saving can be 10%
or even more. This is a result of
ABB's uninterrupted product development focus on reducing losses in
drive components and motors.
ABBs unparalleled Direct Torque
Control (DTC) technology has
become a landmark in the drives
industry thanks to its superior

Energy saving tools


The software tools, PumpSave and
FanSave, have been developed by
ABB for predicting the energy
savings. They are available for
download on the web at
www.abb.com/motors&drives ->
AC drives -> Energy saving
or email energy@fi.abb.com

AC drive efficiency
Motor efficiency in
AC drive use
Total efficiency

Efficiency, %

One of the most tangible benefits of


using AC drives has always been
the saving in energy-related operating costs. AC drives save energy in
many cases, first and foremost in

The new industrial drive, the


ACS800, is equipped with DTC
motor control and exhibits topclass energy efficiency found in the
marketplace today. It is a safe
investment for a company which
values high performance, reliability
and low operating costs.

AC drive efficiency vs. time (75 kW)

ABB has published three EPD


brochures for the ACS800 for the
18.5, 250 and 703 kW power ratings.

Reduce plant operating


costs with the ACS800

control accuracy and frugality in


power usage.

Year - drive technology

3AFE 64572504 REV E EN 17.10.2003

39

ABB Oy
Drives
P. O. Box 184
FIN - 00381 Helsinki
Finland
Telephone
+358 10 22 11
Telefax
+358 10 222 2681
Internet
http://www.abb.com/motors&drives
3AFE 64572504 REV E EN 17.10.2003 Specifications subject to change without notice.