You are on page 1of 110

INDIAN COUNCIL OF AGRICULTURAL

RESEARCH, NEW DELHI


TENDER AND CONTRACT DOCUMENT
Name of Work: Construction of Auditorium at NASC Complex, Pusa Road,
New Delhi

TENDER NO.: RITES/CP/ICAR/AUDI/2011

PART 2: FINANCIAL BID


JUNE 2011

RITESLtd.
(AGovt.ofIndiaEnterprise)
PlotNo.144,Sector44,
Gurgaon(Haryana)122003

Project Name: Construction of Auditorium/Convention Centre at NASC Complex, PUSA, New Delhi.
FINAL ABSTRACT OF COST
Tender No. RITES/CP/ICAR/AUDI/2011
Percentage and Amount to be quoted by the contractor
S.NO.

Particulars

Estimated Cost
(in Rupes)

Civil work (Based on DSR 2007)

Electrical work
2007)

Civil work
Rate)

Electrical work (Based on Market


Rate)

Quoted %age
above/below
(in Figures &
Words)

Quoted
Rupes)

Amount (in

(Based on DSR

(Based

on Market

Total Amount
Un-conditional rebate if any

Amount after rebate in figure

Amount after rebate in Words

(Signature of Contractor with Seal)

CONSTRUCTION OF AUDITORIUM AT NASC COMPLEX, PUSA, NEW DELHI


Abstract of Cost for Civil Works
PART-I Scheduled Items based on DSR 2007 (Reprint DSR 2010)
S.No.

Description of Work

DSR Amount (in Rs.)

Earthwork

Concrete

Masonary Works

9288358.41

Wood, Iron and Steel Works

7096289.05

Joinery works

Flooring Works

10688110.95

Internal & External Finshes

10480714.72

Roofing Works

1416485.00

Water proofing Works

6702770.10

Road Works

2039791.55

Stone works

15582688.52

Plumbing And Sanitation Works


Total Amount

9002619.40
234414451.15

121762.40

1393953.15
308,227,994.40

Remarks

CONSTRUCTION OF AUDITORIUM AT NASC COMPLEX, PUSA, NEW DELHI


BILL OF QUANTITY
PART-I Scheduled Items based on DSR 2007 (Reprint DSR 2010)
Item
No.

DSR Item
No.

Description of Item

Unit

Quantity

Rate (in
Rs.)

Amount in (Rs)

cum

31725.00

101.85

3231191.25

cum

33018.00

18.90

624040.20

cum

650.00

103.40

67210.00

DSR 2.25 Filling available excavated earth (excluding rock) in


trenches, plinth, sides of foundation etc, in layers of not
exceeding 20 cm in depth, consolidating each deposited cum
layer by rammiing and watering lead upto 50 m and lift
upto 1.5 m.

5665.00

45.70

258890.50

DSR 2.27 Supplying and filling in plinth with Jamuna sand under
floors including, watering, ramming consolidating and cum
dressing complete.

972.00

301.50

293058.00

37000.00

76.48

2829760.00

EARTHWORK

Earth work in excavation by mechanical means


(Hydraulic excavator )manual means over areas
(exceeding 30cm in depth. 1.5m in width as well as 10
sqm on plan) including disposal of excavated earth, lead
upto 50m and lift upto 1.5m, disposed earth to be
levelled and neatly dressed.
All kinds of soil

1.1
2
3

3.1
4

6.1

7.1
8

8.1
9
9.1
10

10.1

DSR 2.6.1 up to 1.5 m below G.L.


DSR 2.26.1 Extra for every aditional lift of 1.5m
Earth work in excavation by mechanical means
(Hydraulic excavator )/manual means in foundation
trenches or drains (not exceeding 1.5m in width or 10
sqm on plan) including dressing of sides and ramming of
bottoms, lift upto 1.5 m, including getting out the
excavated soil and disposal of surplus excavated soil as
directed, within a lead of 50 m.
DSR 2.8.1 All kinds of soil.

Disposal of excavated excess earth away from the site


including conveyance of materials up to an average lead
of 1KM away from the site, and correspondiong required
lift, loading, unloading etc complete as directed by the
Engineer-in-charge. (The quantity is net quantity of
capacity of truck after deduction of 20% for
looseness)(considering the maximum disposal location
at 5 KM distance)
DSR 1.12(8 By mechanical transport including loading, unloading
)
and stacking. ( Lead upto 5KM away from the site)
cum
DSR 1.1.2 Extra for transporting earth beyond 5km upto 10 km
including cost of loading,unloading as per the direction of
engineer incharge(The quantity is net quantity of cap. Of
truck after deduction of 0% of voids
By mechanical transport
Earth work in excavation/ by mechanical means
(Hydraulic Excavator)/ manual means over areas
(exceeding 30 cm in depth, 1.5m in width as well as 10
sqm on plan) including disposal of excavated earth, lead
upto 50 m and lift upto 1.5 m, disposed earth to be
levelled and neatly dressed.
DSR 2.7.1 Ordinary rock

cum

37000.00

5.84

216080.00

cum

25.00

152.60

3815.00

cum

50.00

33.85

1692.50

cum

25.00

325.25

8131.25

DSR 2.26 Extra for every additional lift of 1.5 m or part thereof in.
DSR 2.26.2 Ordinary or Hard rock
Earth work in excavation/ by mechanical means
(Hydraulic Excavator)/ manual means over areas
(exceeding 30 cm in depth, 1.5m in width as well as 10
sqm on plan) including disposal of excavated earth, lead
upto 50 m and lift upto 1.5 m, disposed earth to be
levelled and neatly dressed.
DSR 2.7.3 Hard rock (blasting prohibited)

Item
No.

DSR Item
No.

11

11.1

12

13
13.1

14

14.1

DSR
1.1.4(4)

Rate (in
Rs.)

79.07

9488.40

120.00

90.05

10806.00

2.34.01

Chlorpyriphos/Lindane emulsifiable concentrate of 20%

02.035

Diluting and injecting chemical emulsion for POSTCONSTRUCTIONAL anti-termite treatment (excluding
the cost of chemical emulsion)
Along external wall where the apron is not provided
using chemical emulsion @ 7.5 litres/ sqm of the vertical
surface of the substructure to a depth of 300 mm
including excavation channel along the wall and rodding
etc complete:
With chlorpyriphos/Lindane
E.C. 20% with 1% One
6.75
concentration.
Metre

2.35.1

2.35.1.1

14.3

2.35.1.3

14.3(a) 2.35.1.3.1

2.35.5

litre

174.30

Along the external wall below concrete or masonry apron


using chemical emulsion @ 2.25 litres per linear metre
including drilling and plugging holes etc.
With chlorpyriphos/Lindane
E.C. 20% with 1% One
10.45
concentration.
Metre
Treatment of soil under existing floors using chemical
emulsion @ one litre per hole, 300 mm apart including
drilling 12 mm diameter holes and plugging with cement
mortar 1:2 ( 1 cement : 2 coarse sand ) to match the
existing floor.
With Chlorpyriphos/Lindane E.C. 20% with 1% One
48.70
concentration.
Squar
e
Treatment at points of contact of wood work by chemical One
79.80
emulsion chlorpyriphos. (in oil or kerosene based Metre
solution) @ 0.5 litres per hole by drilling 6 mm dia holes
at downward angle of 45 degree at 150 mm centre to
centre and sealing the same.

4000

1.1
1.2

697200.00

4500
30375.00

3000
31350.00

3000
146100.00
500
39900.00

Supplying and stacking at site


DSR 16.3.8 Red Bajri
cum

752.00

654.15

491920.80

DSR 16.11 Dry stone pitching 22.5 cm thick including supply of


sqm
stones and preparing surface complete.

55.00

211.10

11610.50

Total C/o to Summary : Rs.


B

Amount in (Rs)

120.00

Supplying chemical emulsion in sealed containers


including delivery as specified.

2.35.1.2.1

16

Quantity

2.034

14.2
(a)

15.1

By mechanical transport including loading, unloading


and stacking. ( Lead upto 5KM away from the site)
cum

DSR 1.1.4 Extra for transporting rock beyond 5km upto 10 km


including cost of loading,unloading as per the direction of
engineer incharge(The quantity is net quantity of cap. Of cum
truck after deduction of 40% for looseness)

2.35.1.2

15

Unit

Disposal of excavated excess rock away from the site


excluding conveyance of materials upto an average lead
of 1KM away from the site, and correspondiong required
lift, loading, unloading etc complete as directed by the
Engineer-in-charge. (The quantity is net quantity of
capacity of truck after deduction of 40% for
looseness)(considering the maximum disposal location
at 5KM distance)

14.2

14.4

Description of Item

9002619.40

CONCRETE & RCC WORKS


Providing and laying in position cement concrete of
following specified grade excluding the cost of centring
and strutting - All work upto plinth level.
DSR 4.1.8 1:4:8 (1 cement: 4 coarse sand: 8 graded stone
cum
aggregate 40 mm nominal size)

490.00

2449.00

1200010.00

DSR 4.1.6 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone


cum
aggregate 40 mm nominal size).

780.00

2713.05

2116179.00

Item
No.
2

3
3.1

10

11

DSR Item
No.

Description of Item

Unit

Quantity

Rate (in
Rs.)

Amount in (Rs)

DSR 5.33 Providing and laying in position machine batched,


machine mixed and machine vibrated design mix cement
concrete of specified grade for reinforced cement
concrete work including pumping of concrete to site of
laying but excluding the cost of centering,shuttering,
finishing and reinforcement. including Admixtures in
recommended proportions as per IS 9103 to accelerate, cum
retard setting of concrete, improve workability without
impairing strength and durability as per direction of
Engineer-in-charge. M-25 grade reinforced cement
concrete by using 380kg. of cement per cum of concrete.
All work upto plinth level.

7520.00

3983.75

29957800.00

18159.00

109.10

1981146.90

3500.00

528.15

1848525.00

DSR 5.33 A Providing and laying in position machine batched,


machine mixed and machine vibrated design mix cement
concrete of specified grade for reinforced cement
concrete work including pumping of concrete to site of
laying but excluding the cost of centering, shuttering,
finishing and reinforcement. including Admixtures in
recommended proportions as per IS 9103 to accelerate, cum
retard setting of concrete, improve workability without
impairing strength and durability as per direction of
Engineer-in-charge. M-25 grade reinforced cement
concrete by using 380kg. of cement per cum of concrete.
All work above plinth level up to floor V level.

10692.00

3983.75

42594255.00

DSR 5.13 Providing, hoisting and fixing upto floor five level precast
reinforced cement concrete in small lintels not exceeding
1.5m clear span upto floor five level including the cost of
required centring, shuttering and finishing smooth with
6 mm thick cement plaster 1:3 (1 cement : 3 fine sand) cum
on exposed surfaces but excluding the cost of
reinforcement with 1:2:4 (1 cement : 2 coarse sand : 4
graded stone aggregate 20mm nominal size).

50.00

6002.80

300140.00

DSR 4.11 Providing and laying damp-proof course 50mm thick with
cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 Sqm
graded stone aggregate 20mm nominal size).

100.00

178.05

17805.00

10.00

92.90

929.00

100.00

58.60

5860.00

500.00

222.65

111325.00

Add or deduct for providing leaner or richer mixes


respectively at all floor levels.
DSR 5.34.1 Providing M 30 Grade concrete by using 400 Kg of
cement per CUM of concrete instead of M25 grade BMC cum
/ RMC
DSR 5.35 Deduct for using less cement than the quantity as
provided in the item of batch mix concrete/RMC as Quinta
l
arrived as per mix design.

DSR 5.38 Extra for R.C.C./ B.M.C/ R.M.C. work above floor V level
for each four floors or part thereof.
cum
DSR 4.13 Applying a coat of residual petroleum bitumen of
penetration 80/100 of approved quality using 1.7kg per
square metre on damp proof course after cleaning the sqm
surface with brushes and finally with a piece of cloth
lightly soaked in kerosene oil.
DSR 4.17 Making plinth protection 50mm thick of cement concrete
1:3:6 (1cement :3 coarse sand : 6graded stone
aggregate 20mm nominalsize) over 75mm bed by dry Sqm
brick ballast 40mm nominal size well rammed and
consolidated and grouted with fine sand including
finishing the top smooth
Centering and shuttering including strutting, propping
etc. and removal of formwork for :

11.1

DSR 4.3.1 Foundations, footings, bases of columns

7.00

119.25

834.75

11.2

DSR 5.9.1 Foundations, footings, bases of columns etc. for mass


sqm
concrete.

5216.00

119.25

622008.00

11.3

DSR 5.9.2 Walls (any thickness) including attached pilasters,


sqm
butteresses, plinth and string courses etc.

4380.00

180.40

790152.00

DSR 5.9.3 Suspended floors, roofs, landings, balconies and access


sqm
platform.

19040.00

187.35

3567144.00

DSR 5.9.5 Lintels, beams, plinth beams, girders, bressumers and


sqm
cantilevers.

24765.00

162.65

4028027.25

11.4
11.5

sqm

Item
No.

DSR Item
No.

Unit

Quantity

Rate (in
Rs.)

Amount in (Rs)

11.6

DSR 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts

sqm

6107.00

238.40

1455908.80

11.7

DSR 5.9.7 Stairs, (excluding landings) except spiral-staircases.

11.8

sqm

4112.00

204.00

838848.00

DSR 5.9.13 Vertical and horizontal fins individually or forming box


sqm
louvers band, facias and eaves boards.

100.00

285.55

28555.00

DSR 5.9.15 Small lintels not exceeding 1.5m clear span, moulding
as in cornices, window sills, string courses,
sqm
bands,copings, bed plates, anchor blocks and the like.

6610.00

119.25

788242.50

11.10 DSR 5.9.14 Extra for shuttering in circular work ( 20% of respective
centering and shuttering items) for Roof beams
Sqm

19040.00

0.20

3808.00

Sqm

115.00

258.60

29739.00

DSR 5.9.5 Lintels, beams, plinth beams, girders, bressumers and


sqm
cantilevers.

436.00

162.65

70915.40

123276.00

70.20

8653975.20

Kg

1022768.00

42.70

43672193.60

Kg.

2100765.00

42.70

89702665.50

71.00

386.75

11.9

Description of Item

11.11 DSR 5.9.19 Weather shade, Chajjas, corbels etc., including edges
11.12

12

12.1

13

Extra for additional height in centering, shuttering where


ever required with adequate bracing, propping etc.
including cost of de-shuttering and decentering at all
levels, over a height of 3.5m, for every additional height
of 1 metre or part thereof (Plan area to be measured)
DSR 5.11.1 Suspended floors, roofs, landing, beams and balconies
sqm
(Plan area to be measured).
Steel Reinforcement
DSR 5.22.6 Reinforcement for R.C.C. work including straightening,
cutting, bending, placing in position and binding all
complete. Upto plinth level.

13.1
14

14.1
15

15.1

Thermo-Mechanically Treated bars. Fe500


DSR
5.22.A6

Reinforcement for R.C.C. work including straightening,


cutting, bending, placing in position and binding all
complete. Above plinth level.
Thermo-Mechanically Treated bars. Fe500

DSR 22.4 Providing and Placing in position suitable PVC water


stops confirming to IS 12200 for Construction /
Expansion joints between two RCC members and fixed
to the reinforcement with binding wire before concrete
etc
DSR 22.4.1 Serrated with central bulb (22.5mm wide , 8-11 mm th)
metre
Total carried over to summary : Rs.

C
1

2.1
3

27459.25
234414451.15

MASONRY WORKS
Brick work with F.P.S. bricks of class designation 75 in
DSR 6.1.2 foundation and plinth in: Cement mortar 1:6 (1 cement : cum
6 coarse sand)

368.00

2121.75

780804.00

3398.00

2430.25

8257989.50

28.30

270.35

7650.91

690.00

302.80

208932.00

690.00

47.80

32982.00

Brick work with F.P.S. bricks of class designation 75 in


superstructure above plinth level up to floor V level in all
shapes and sizes in :
DSR 6.4.2 Cement mortar 1:6 (1 cement : 6 coarse sand)

cum

DSR 6.12.2 Half brick masonry with F.P.S. brick of class designation
75 in foundations and plinth in : cement mortar 1:4 (1 Sqm
cement : 4 coarse sand)
DSR 6.13.2 Half brick masonry with F.P.S. bricks of class
designation 75 in superstructure above plinth level upto
sqm
floor V level. cement mortar 1:4 (1 cement : 4 coarse
sand)
DSR 6.15 Extra for providing and placing in position 2 Nos. 6mm
dia. M.S. bars at every third course of half brick masonry Sqm
(with F.P.S. bricks).
Total C/o to Summary : Rs.

9288358.41

Item
No.

DSR Item
No.

D
1

2.1
3
4

5.1

Unit

Quantity

Rate (in
Rs.)

Amount in (Rs)

Kg

146575.00

46.35

6793751.25

Sqm

35.00

1208.45

42295.75

each

10.00

356.50

3565.00

270.00

64.40

17388.00

7.00

1695.40

11867.80

2765.00

82.25

227421.25

WOOD, Structural STEEL WORKS


DSR 10.2 Structural steel work riveted, bolted or welded in built up
sections,trusses and framed work, including cutting,
hoisting, fixing in position and applying a priming coat of
approved steel primer all complete:
Supplying and fixing rolling shutters of approved make,
made of required size M.S. laths interlocked together
through their entire length and jointed together at the end
by end locks mounted on specially designed pipe shaft
with brackets, side guides and arrangements for inside
and outside locking with push and pull operation
complete including the cost of providing and fixing
necessary 27.5cm long wire springs grade No.2 and
M.S. top cover of required thickness for rolling shutters.
DSR 10.6.1 80x1.25 mm M.S. laths with 1.25 mm thick top cover
DSR 10.7 Providing and fixing ball bearing for rolling shutters.
DSR 9.48.2 Providing and fixing M.S. grills of required pattern in
frames of windows etc. with M.S. flats, square or round
bars etc. all complete.
Fixed to openings /wooden frames with rawl plugs
kg
screws etc.
Providing and fixing 1mm thick M.S. sheet door with
frame of 40x40x6mm angle iron and 3mm M.S. gusset
plates at the junctions and corners, all necessary fittings
complete, including applying a priming coat of approved
steel primer.
DSR 10.5.1 Using M.S. angels 40x40x6 mm for diagonal braces.
sqm

6.1

Description of Item

Providing and fixing hand rail of approved size by


welding etc. to steel ladder railing, balcony railing and
staircase railing including applying a priming coat of
approved steel primer.
DSR
10.26.2

E.R.W. tubes

kg
Total C/o to Summary : Rs.

E
1

JOINERY WORKS
DSR
14.28.1

Providing and fixing curtain rods of 1.25mm thick brass


plates with two brass brackets fixed with brass screws
and wooden plugs etc. wherever necessary complete.
20 mm diameter.

7096289.05

metre

227.00

116.20

each

50.00

1907.70

26377.40

DSR 21.4.2 Providing and fixing double action hydraulic floor spring
of approved brand and manufacture IS : 6315 marked,
for doors including cost of cutting floors as required,
embedding in floors and cover plates with brass pivot
and single piece M.S. sheet outer box with slide plate
etc.complete as per the direction of Engineer-in-charge.
With brass cover plate
Total C/o to Summary : Rs.

95385.00
121762.40

Item
No.

DSR Item
No.

F
1

3.1
4

Unit

Quantity

Rate (in
Rs.)

Amount in (Rs)

405.00

286.50

116032.50

FLOORING WORKS
DSR 11.4 52 mm thick cement concrete flooring with concrete
hardener topping under layer 40 mm thick cement
concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded
stone aggregate 20 mm nominal size) and top layer 12
mm thick cement hardener consisting of mix 1:2 (1
cement hardener mix : 2 graded stone aggregate 6 mm sqm
nominal size) by volume .hardening compound is mixed
@ 2 litre per 50kg of cement or as per manufacturers
specifications. This includes cost of cement slurry, but
excluding the cost of nosing of steps etc. complete. (
UTILITY BUILDING )
DSR
11.41.2

2.1
3

Description of Item

Providing and laying vitrified floor tiles in different sizes


(thickness to be specified by the manufacturer) with
water absorption's less than 0.08% and conforming to IS
: 15622 of approved make in all colours and shades, laid
on 20mm thick cement mortar 1:4 (1 cement : 4 coarse
sand) including grouting the joints with white cement and
matching pigments etc., complete.
Size of Tile 60x60 cm

DSR
11.26.1

sqm

1650.00

1031.85

1702552.50

Kota stone slab flooring over 20 mm (average) thick


base laid over and jointed with grey cement slurry mixed
with pigment to match the shade of the slab including sqm
rubbing and polishing complete with base of cement
mortar 1 : 4 (1 cement : 4 coarse sand) :

592.00

694.4

411084.80

392.00

676.75

265286.00

1264.00

26.40

33369.60

25 mm thick.
DSR 11.27 Kota stone slabs 25 mm thick in risers of steps, skirting,
dado and pillars laid on 12 mm (average) thick cement
mortar 1:3 (1 cement 3 coarse sand) and jointed with
sqm
grey cement slurry mixed with pigment to match the
shade of the slabs, including rubbing and polishing
complete.
DSR 11.31 Extra for pre finished nosing in treads of steps of Kota
metre
stone/ Sand Stone Slab

Item
No.
6

DSR Item
No.

Unit

Quantity

DSR 11.5 62 mm thick cement concrete flooring with concrete


hardener topping under layer 50 mm thick cement
concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded
stone aggregate 20mm nominal size) and top layer
12mm thick cement hardener consisting of mix 1:2 (1
cement hardener mix : 2 graded stone aggregate 6mm sqm
nominal size) by volume. Hardening compound is mixed
@ 2 litre per 50kg of cement or as per manufactures
specifications. This includes cost of cement slurry, but
excluding the cost of nosing of steps etc. complete.

7731.00

318.65

2463483.15

sqm

82.00

192.95

15821.90

kg

1153.00

529.5

610513.50

each

6000.00

18.95

113700.00

sqm

3000.00

1562.5

4687500.00

sqm

30

2480.20

74406.00

sqm

50

2575.1

128755.00

40mm thick with 20 mm nominal size stone aggregate

Stainless Steel Cramps


DSR 8.8.1.2 Providing and fixing expansion hold fastners on CC/
RCC surface backing including drilling necessary holes
and the cost of bolt etc. complete. Wedges expansion
type

9.1
10

Fastener with threaded dia 10 mm.


DSR 8.1.1.2 Marble work gang saw cut (polished and machine cut) of
thickness18mm for wall lining (veneer work) in cement
mortar 1:3 (1 cement : 3coarse sand) including pointing
with white cement mortar 1:2 (1 white cement : 2 marble
dust) with an admixture of pigment to match the marble
shade: (To be secured to the backing by means of
cramps, which shall be paid for separately).
Raj Nagar Plain white marble/ Udaipur green marble/
Zebra black marble.
Area of slab over 0.50 sqm

10.1
11

Amount in (Rs)

DSR 8.7.2 Providing and fixing cramps of required size & shape in
RCC/ CC backing with cement mortar 1:2 ( 1 cement :2
coarse sand) including drilling necessary hole in stones
and embedding the cramp in the hole (fasstner to be
paid separetely)

8.1
9

Rate (in
Rs.)

DSR 11.3.1 Cement concrete flooring 1:2:4 (1 cement : 2 coarse


sand : 4 graded stone aggregate) finished with a floating
coat of neat cement including cement slurry, but
excluding the cost of nosing of steps etc. complete.

7.1
8

Description of Item

8.2

Providing and fixing 18 mm thick gang saw cut mirror


polished premoulded and prepolished ), machine cut for
kitchen platforms, vanity counters facias and similar
locations of required size of approved shade, colour and
texture laid over 20 mm thick base cement mortar 1:4 (1
cement : 4 coarse sand )with joints treated with white
cement, mixed with matching pigment, epoxy touch ups,
including rubbing, curing moulding and polishing to
edge to give high gloss finish etc., complete at all levels.
Granite of any colour and shade

11.1
11.2

8.2.2.1

DSR 8.22.2 Area of slab over 0.50 sqm.

12

8.3

12.1

8.3.2

13

8.4

14

Area of slab upto 0.5 sqm

8.5

Extra for edge moulding to 18mm thick marble stone


counters, Vanities etc., including machine polishing to
edge to give high gloss finish etc., complete as per
design approved by Engineer-in-charge.
Granite work

metre

225

97.60

21960.00

Extra for fixing marble / granite stone over and above


corresponding basic item, in facia and drops of width
upto 150mm with epoxy resin based adhesive including metre
cleaning etc., complete.

225

106.80

24030.00

Extra for providing opening of required size & shape for


wash basins / kitchen sink in kitchen platform, vanity
counters and similar location in marble / granite / stone
work including necessary holes for pillar taps etc., each
including rubbing and polishing of cut edges etc.,
complete.

80

151.00

12080.00

Item
No.

DSR Item
No.

15

8.6

Description of Item

Unit

Mirror polishing on marble work / granite work / stone


work where ever rquired to give high gloss finish sqm
complete.

Quantity

Rate (in
Rs.)

Amount in (Rs)

80

94.20

7536.00

Total C/o to Summary : Rs.


G
1

DSR 13.2.1 15 mm cement plaster on the rough side of single or half


brick wall of mix

1.1
2

3
4

10688110.95

Internal and External Finishes

1:4 (1 cement:4 fine sand)

sqm

16060.67

90.35

1451081.53

DSR 13.22 Extra for plastering exterior walls of height more than 10
m from ground level for every additional height of 3 m or sqm
part thereof.

5400.00

16.8

90720.00

20560.00

77.55

1594428.00

19150.00

128.5

2460775.00

3500.00

28.85

100975.00

sqm

1879.00

62.15

116779.85

Sqm

14809.00

6.75

99960.75

55770.67

41.55

2317271.34

19150.00

60.1

1150915.00

20560.00

51.3

1054728.00

DSR 13.1.1 12 mm cement plaster of mix :1:4 (1 cement: 4 fine


sqm
sand)
DSR 13.10 15 mm cement plaster 1:3 (1 cement: 3 coarse sand)
finished with a floating coat of neat cement on the rough sqm
side of single or half brick wall.
DSR 13.21 Extra for providing and mixing water proofingmaterial in Per
cement plaster work in proportion recommended by the Bag of
manufacturers.
50kg of
cement
used in
the mix

DSR
13.16.1

6 mm cement plaster of mix : 1:3 (1 cement: 3 fine sand)

DSR
13.37.1

White washing with lime to give an even shade

7.1
8

New work (three or more coats)


DSR
13.41.1

DSR
13.47.1

9.1

10

New work (Two or more coats applied @ 1.43 ltr/ 10


sqm. over and including base coat of water proofing sqm
cement paint applied @ 2.20 kg/ 10 sqm).
DSR
13.62.10

10.1

11

11.1

12

Distempering with oil bound washable distemper of


approved brand and manufacture to give an even shade:
sqm
New work (two or more coats) over and including priming
coat with cement primer.
Finishing walls with Premium Acrylic Smooth exterior
paint with Silicone additives of required shade

Painting with synthetic enamel paint of approved brand


and manufacture of required colour to give an even
shade:
Two or more coats on new work over an under coat of
suitable shade with ordinary paint of approved brand and sqm
manufacture.
Finishing walls with textured exterior paint of required
shade :

DSR
13.45.1

New work (Two or more coats applied @ 3.28 ltr/10 sqm)


over and including base coat of water proofing cement sqm
paint applied @ 2.20kg/10 sqm.
Painting with synthetic enamel paint of approved brand
and manufacture of required colour to give an even
shade:

338.00

32532.50
96.25

Item
No.

DSR Item
No.

12.1

DSR
13.62.1

13

Description of Item

Unit

Two or more coats on new work over an under coat of


suitable shade with ordinary paint of approved brand sqm
and manufacture

DSR 13.21 Extra for providing and mixing water proofing material in Per
cement plaster work in proportion recommended by the bag of
50kg.
manufacturers.
of
cement
used in

Quantity

Rate (in
Rs.)

175.00

8977.50
51.3

55.00

1570.25
28.55

Total C/o to Summary : Rs.


H
1

2.1

2.3

10480714.72

ROOFING WORKS
DSR 12.50 Providing and fixing precoated galvanised iron profile
sheets (size, shape and pitch of corrugation as approved
by Engineer-in-charge) 0.50 mm + 5% total coated
thickness (TCT), Zinc coating 120gsm as per IS: 277 in
240mpa steel grade, 5-7 microns epoxy primer on both
side of the sheet and polyester top coat 15-18 microns.
Sheet should have protective guard film of 25 microns
minimum to avoid scratches while transportation and
should be supplied in single length upto 12 metre or as
desired by Engineer-in-charge. The sheet shall be fixed sqm
using self drilling /self tapping screws of size (5.5x
55mm) with EPDM seal or with polymer coated J or L
hooks, bolts and nuts 8mm diameterwith bitumen and
G.I. limpet washers or with G.I. limpet washers filled with
white lead complete upto any pitch in horizontal/ vertical
or curved surfaces excluding the cost of purlins, rafters
and trusses and including cutting to size and shape
wherever required.

2.2

Amount in (Rs)

2820.00

440.65

1242633.00

metre

56.00

458.15

25656.40

metre

120.00

547.8

65736.00

metre

184.00

448.15

82459.60

Providing and fixing precoated galvanised steel sheet


roofing accessories 0.50 mm + 5% total coated
thickness (TCT), Zinc coating 120gsm as per IS: 277 in
240mpa steel grade, 5-7 microns epoxy primer on both
side of the sheet and polyester top coat 15-18 microns
using self drilling/ self tapping screws or with polymer
coated J or L hooks, bolts and nuts and or G.I. seam
bolts and nuts, G.I. plain and bitumen washers complete
DSR
12 51 1
DSR
12.51.6
DSR
12.51.2

Ridges plain (500 - 600mm).


Gutter .(600 mm over all girth).
Flashings / Aprons ( Up to 600 mm )

Total C/o to Summary : Rs.

1416485.00

Item
No.
I

DSR Item
No.

Description of Item

Unit

Quantity

Rate (in
Rs.)

Amount in (Rs)

Sqm

5593.00

545.1

3048744.30

Sqm

1800.00

647.85

1166130.00

WATER PROOFING WORKS


Water proofing for basement

1.1
2

2.1
3

DSR 22.1 Providing and laying integral cement based treatment for
water proofing on horizontal surface at all depth below
ground level for under ground structures as directed by
Engineer-in-Charge and consisting of : i) Ist layer of
22mm to 25mm thick approved and specified rough
stone slab over a 25mm thick base of cement mortar 1:3
(1 cement : 3 coarse sand) mixed with water proofing
compound conforming to IS:2645 in the recommended
proportion over the leveling course (leveling course to be
paid separately). Joints sealed and grouted with cement
slurry mixed with water proofing compound. ii) 2nd layer
of 25mm thick cement mortar 1:3 (1 cement: 3 coarse
sand) mixed with water proofing compound in
recommended proportions. iii) Finishing top with stone
aggregate of 10mm to 12mm nominal size spreading @
8 cudm/sqm thoroughly embedded in the 2nd layer.
DSR 22.1.1 Using rough kota stone.
DSR 22.2 Providing and laying integral cement based treatment for
water proofing on the vertical surface by fixing specified
stone slab 22 mm to 25mm thick with cement slurry
mixed with water proofing compound conforming to
IS:2645 in recommended proportions with a gap of
20mm (minimum) between stone slabs and the receiving
surfaces and filling the gaps with neat cement slurry
mixed with water proofing compound and finishing the
exterior of stone slab with cement mortar 1:3 (1 cement :
3 coarse sand) 20mm thick with neat cement punning
mixed with water proofing compound in recommended
proportion complete at all levels and as directed by
Engineer-in-charge
DSR 22.2.1 Using rough Kota stone
DSR 22.3 Providing and laying water proofing treatment to vertical
and horizontal surfaces of depressed portions of W.C.,
kitchen and the like consisting of :
i) Ist course of applying cement slurry @ 4.4 Kg/sqm
mixed with water proofing compound conforming to IS
2645 in recommended proportions including rounding off
junction of vertical and horizontal surface.
IInd course of 20mm cement plaster 1:3 (1 cement : 3
coarse sand) mixed with water proofing compound in
recommended proportion including rounding off junction
of vertical and horizontal surface.

Item
No.

DSR Item
No.

Description of Item

Unit

Quantity

Rate (in
Rs.)

Amount in (Rs)

IIIrd course of applying blown or residual bitumen applied


hot at 1.7 Kg. per sqm of area.
3.1

4
4.1
5

IVth course of 400 micron thick PVC sheet. (Overlaps at


joints of PVC sheet should be 100 mm wide and pasted Sqm
to each other with bitumen @ 1.7 Kg/sqm.)

7.1

DSR
22.14.1

Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4


Cum
graded stone aggregate 20 mm nominal size)

DSR
12.21.1

Providing gola 75x75 mm in cement concrete 1:2:4 (1


cement : 2 coarse sand : 4 stone aggregate 10mm and
down gauge) including finishing with cement mortar 1:3
(1 cement : 3 fine sand) as per standard design :
In 75x75mm deep chase

metre

DSR 12.22 Making khurras 45x45 cm with average minimum


thickness of 5 cm cement concrete 1:2:4 (1 cement : 2
coarse sand : 4 graded stone aggregate of 20 mm
nominal size) over P.V.C. sheet
each
1mx1mx400micron, finished with 12mm cement plaster
1:3 (1 cement : 3 coarse sand) and a coat of neat
cement rounding the edge sand making and finishing the
outlet complete
DSR
Providing and fixing on wall face unplasticised Rigid
12.41.2 PVC rain water pipes conforming to IS : 13592 Type A
including jointing with seal ring conforming to IS : 5382
leaving 10 mm gap for thermal expansion.(i) Single
socketed pipes.
110 mm diameter
metre

8.1

272.5

221542.50

400.00

3314.95

1325980.00

400.00

67.35

26940.00

60.00

108

6480.00

DSR 22.14 Grading roof for water proofing treatment with

5.1
6

813.00

1105.00

163.4

180557.00

240.00

101.65

24396.00

Providing and fixing on wall face unplasticised - PVC


moulded fittings/ accessories for unplasticised Rigid
PVC rain water pipes conforming to IS : 13592 Type A
including jointing with seal ring conforming to IS : 5382
leaving 10 mm gap for thermal expansion.
DSR
12.42.1.2

Couplers 110 mm
Each

Item
No.

DSR Item
No.

8.2

DSR
12.42.5.2

BEND 87.5 degree ( 110 mm Bend )

8.3

DSR
12.42.6.2

Shoe (Plain) 110 mm

9.1

DSR
12.42.5.1

Description of Item

Unit

Quantity

Each

122.00

134.2

16372.40

Each

122.00

263.1

32098.20

each

2.00

88.4

176.80

2.00

152.25

304.50

each

40.00

182.4

7296.00

455x610 mm rectangular C.I. cover (light duty) the


each
weight of the cover to be not less than 23 kg.

3.00

1007.45

3022.35

2.00

9938.6

19877.20

Providing and fixing on wall face Unplasticised - PVC


moulded fittings/ accessories for Unplasticised Rigid
PVC rain water pipes conforming to IS : 13592 Type A
including jointing with seal ring conforming to IS : 5382
leaving 10 mm gap for thermal expansion.
Bend 87.5
75 mm bend

Rate (in
Rs.)

Amount in (Rs)

Shoe (Plain)
9.2
10

DSR
75 mm Shoe
each
12.42.6.1
DSR 19.16 Providing Orange colour saftey foot rest of minimum 6
thick mm Plastic encapsulated as per IS 10910 on 12
mm dia steel bar conforming IS 1786 having minimum
cross section as 23mm X 25 mm and over all minimum
length 263 mm and Width as 165mm with minimum
112mm space between protued legs having 2mm tread
on top surface by ridding chequred besides beside
necessary and adequate anchoring projections on tail
length on 138mm as per standard drawing and suitable
with stand and bend test and chemical resistence test as
per specifications and having manufacture's permenent
identification mark to be visible even after finishing,
including fixing in manhole with 30x20x15 cm cement
concrete block 1:3:6 (1 cement: 3 course sand: 6 graded
stone aggregate 20mm nominal size) complete as per
design

10.1
11
11.1
12

12.1

With 20 mm diameter round bar


DSR 19.18 Supplying and fixing C.I. cover without frame for
manholes:
DSR
19.18.1

DSR 19.32 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x
45 cm dry brick honey comb shaft with bricks of class
designation 75 and S.W. drain pipe 100 mm diameter,
1.8 m long complete as per standard design.
DSR
19.32.1

With F.P.S. bricks

each

Item
No.
13

DSR Item
No.

Description of Item

Unit

Quantity

Rate (in
Rs.)

each

9.00

15673.85

2.00

3179.95

Amount in (Rs)

DSR 19.7 Constructing brick masonry manhole in cement mortar


1:4 ( 1 cement : 4 coarse sand ) R.C.C. top slab with
1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone
aggregate 20 mm nominal size), foundation concrete
1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone
aggregate 40mm nominal size) inside plastering 12mm
thick with cement mortar 1:3 (1 cement : 3 coarse sand)
finished with floating coat of neat cement and making
channels in cement concrete 1:2:4 (1 cement : 2 coarse
sand : 4 graded stone aggregate 20mm nominal size)
finished with a floating coat of neat cement complete as
per standard design :
DSR 19.7.3 Inside size 120x90 cm and 90 cm deep including C.I.
cover with frame (heavy duty) 560 mm internal diameter,
total weight of cover and frame to be not less than 208
kg (weight of cover 108 kg and weight of frame 100 kg) :

13.1
14
14.1
15

15.1
15.2
16

17

18

19

With F.P.S. bricks with class designation 75

DSR
19.8.2.1

Size 120 x 90 cm with F.P.S bricks with class


metre
designation 75
Providing and fixing square-mouth S.W. gully trap class
SP-1complete with C.I. grating brick masonry chamber
with water tight C.I.cover with frame of 300 x300 mm size
(inside) the weight of cover tobe not less than 4.50 kg
and frame to be not less than 2.70 kg as perstandard
design
DSR 19.4.1 100x100mm size plate
DSR
19 4 1 1
DSR
12.43.2

with F.P.S. bricks class designation 75

each

Providing and fixing unplasticised -PVC pipe clips of


approved design to unplasticised - PVC rain water pipes
by means of 50x50x50mm hard wood plugs, screwed
with M.S. screws of required length including cutting Each
brick work and fixing in cement mortar 1:4 (1 cement : 4
coarse sand) and making good the wall etc. complete. 110MM
DSR 12.44 Providing and fixing to the inlet mouth of rain water pipe
cast iron grating 15 cm dia and weighing not less than Each
440 grms
DSR 10.18 Providing and fixing circular/ Hexagonal cast iron or M.S.
sheet box for ceiling fan clamp of internal dia 140mm,
73mm height, top lid of 1.5mm thick M.S. sheet with its
top surface hacked for proper bonding, top lid shall be
screwed into the cast iron/ M.S. sheet box by means of Each
3.3mm dia. round headed screws, one lock at the
corners. Clamp shall be made of 12mm dia M.S. bar
bent to shape as per standard drawing.
DSR 16.68 Providing and laying 60mm thick factory made cement
concrete interlocking paver block of M -30 grade made
by block making machine with strong vibratory
compaction and of approved size and design/ shape
laid in required colour and pattern over and including sqm
50mm thick compacted bed of course sand, filling the
joints with coarse sand etc. all complete as per the
direction of Engineer-in-charge.

2.00

935.15

2
2.1
2.2

6359.90

1870.30

1200.00

96.9

116280.00

120.00

23.4

2808.00

100.00

81.2

8120.00

1000.00

346.35

Total C/o to Summary : Rs.


J

141064.65

DSR 19.8 Extra for depth for manholes

346350.00

6702770.10

ROAD WORKS
DSR 16.1 Preparation and consolidation of subgrade with power
road roller of 8 to 12 tonne capacity after excavating
earth to an average of 22.5 cm depth, dressing to
camber and consolidating with road roller including Sqm
making good the undulations etc. and rerolling the
subgrade and disposal of surplus earth lead upto 50
metres.
Supplying and stacking at site
DSR
Moorum
16.3.10
DSR 16.3.6 Stone screening 13.2 mm nominal size (Type A).

2400.00

33.90

81360.00

Cum

40.00

421.85

16874.00

cum

20.00

892.25

17845.00

Item
No.

DSR Item
No.

Description of Item

Unit

Quantity

Rate (in
Rs.)

Amount in (Rs)

cum

20.00

979.40

19588.00

cum

240.00

742.30

178152.00

cum

240.00

768.45

184428.00

DSR 16.6.1 Supply, Stacking and Spreading 6 mm thick red bajri,


watering and rolling complete including preparation of Sqm
the surface and rolling with road roller/hand roller.

720.00

6.70

4824.00

480.00

192.55

92424.00

330

3692.40

1218492.00

2244

33.70

75622.80

7500

2.00

15000.00

1500

1.10

1650.00

metre

115.00

499.55

57448.25

metre

85.00

895.10

76083.50

2.3

DSR 16.3.7 Stone screening 11.2 mm nominal size (Type B).

2.4

DSR 16.3.1 90 mm to 45 mm size stone aggregate.

2.5

DSR 16.3.2 63 mm to 45 mm size stone aggregate.

DSR 16.4 Laying , spreading and compacting stone aggregate of


specified sizes to WBM specifications including
spreading in uniform thickness, hand picking , rolling
with 3 wheeled road / vibratory roller 8-10 tonne in
cum
stages to proper grade and camber, applying and
brooming requisite type of screening / binding material
to fill up interstices of coarse aggregate watering and
compacting to the required density .
DSR 16.43 Providing and laying design mix cement concrete in
roads, taxi tracks and runways having a minimum works
test beam flexural strength of 30 kg. per cm2. at 28 days
using not less than 340 Kg. of cement per cum of
finished concrete, coarse sand and graded stone
aggregate of 40mm nominal size in appropriate
proportions as per specified design criteria approved by
Engineer-in-charge mechanically vibrated using needle
and surface vibrators including steel form work with cum
sturdy M. S. channel sections including curing and
providing and filling construction joints and dummy joints
with shalijet primer or equivalent including rounding of
the edges and filling the grooves 10x25mm deep at top
for construction joints and 10mmx50mm deep at top for
dummy joints with joint sealing compound (conforming to
grade B of IS : 1834) including making necessary
arrangements for expansion joints etc. all complete.

DSR 16.44 Extra for providing and mixing hard crete of approved
Litre
quality as per manfuacture specification.

DSR16.45 Providing and fixing in position premoulded joint filler in


expansion joints.

8.1
9

per
cm.
depth
per
DSR 16.46 Providing and laying in position bitumen hot sealing per
compound for expansion joints etc.
cm.
depth
per
Using grade A sealing compound.
DSR 19.6 Providing and laying non-pressure NP2 class (light duty)
R.C.C. pipes with collars jointed with stiff mixture of
cement mortar in the proportion of 1:2 (1 cement : 2 fine
sand) including testing of joints etc. complete:

9.1

DSR 19.6.5 a)450 mm dia. R.C.C. pipe

9.2

DSR 19.6.7 b)600 mm dia. R.C.C. pipe

Stone Work

Total C/o to Summary : Rs.

1.1

DSR 7.40 Providing and fixing dry cladding upto 10 metre heights
with 30mm thick gang saw cut stone with (machine cut
edges) of uniform colour and size upto 1mx1m, fixed to
structural steel frame work and/ or with the help of
cramps, pins etc. and sealing the joints with approved
weather sealant as per Architectural drawing and
direction of Engineer-in-charge. (The steel frame work,
stainless steel cramps and pins etc. shall be paid for
separately )
DSR 7.40.2 White sand stone or bansi- paharpur stone

2039791.55

Sqm

1851.86

1382.35

2559918.67

Item
No.
2

DSR Item
No.

Description of Item

Unit

Quantity

Rate (in
Rs.)

Amount in (Rs)

142450.77

77.80

11082669.85

7000.00

272.50

1907500.00

800.00

40.75

32600.00

DSR 7.41 Providing and fixing structural steel frame (for dry
cladding with 30 mm thick gang saw cut with machine
cut edges sand stone) on walls at all heights using M.S.
square/ rectangular tube in the required pattern as per
architectural drawing including cost of cutting, bending,
welding etc. The framework shall be supported in wall
with the help of MS brackets/lugs of angle iron/ flats etc.
which shall be welded to theframe and embedded in
brick wall with cement concrete block 1:2:4 (1 cement :2
coarse sand :4 graded stone aggregate 20mm nominal
size) of size 300x230x300mm including cost of
necessary centring and shuttering and with approved
expansion hold fasteners on CC/RCC surface including
drilling necessary holes.
Approved cramps/ pinsetc. shall be welded to the frame
work to support stonecladding the steel work will be
given a priming coat of Zinc primer as approved by
Engineer-in-charge and painted with two or more coats
of epoxy paint (Shop drawings shall be submitted by the
contractor to the Engineer-in-charge for approval before Kg
execution). The frame work shall be fixed in true
horizontal & vertical lines/planes. (Only structural steel
frame work shall be measured for the purpose of
payment, stainless steel cramps shall be paid for
separately and nothing extra shall be paid.)
DSR 7.42 Providing and fixing adjustable stainless steel cramps of
approve quality and of required shape and size
adjutable with stainless steel nuts bolts and washer (
total weight not less than 260 gms) for dry stone
Each
cladding fixed on frame work at suitable location
including making necessary recesses in stane slab,
drilling required holes etc. complete as per direction of
engineer in charge.
DSR 7.39 Extra for stone work for wall lining on exterior wallsof
height more than 10 m from ground level for every Sqm
additional height of 3 m or part there of.
Total C/o to Summary : Rs.

L
1

15582688.52

PLUMBING AND SANITATION


Providing and fixing water closet squatting pan (Indian
type W.C. pan ) with 100mm sand cast Iron P or S trap,
10 litre low level white P.V.C. flushing cistern with
manually controlled device (handle lever) conforming to
IS : 7231, with all fittings and fixtures complete including
cutting and making good the walls and floors wherever
required :
White Vitreous china Orissa pattern W.C. pan of size
DSR 17.1.1 580x440mm with integral type foot rests.
Each

10.00

2304.65

23046.50

Metre

125.00

155.15

19393.75

Metre

40.00

175.50

7020.00

INTERNAL WATER SUPPLY


2

Providing and fixing Chlorinated Polyvinyl Chloride


(CPVC) pipes, having thermal stability for hot & cold
water supply including all CPVC plain & brass threaded
fittings i/c fixing the pipe with clamps at 1.00 m spacing.
This includes jointing of pipes & fittings with one step
CPVC solvent cement and the cost of cutting chases
and making good the same including testing of joints
complete as per direction of Engineer in charge.
Concealed work including cutting chases and makin
good the walls, etc

2.1
2.2
3

DSR 18.8.1
DSR 18.8.2

15 mm nominal outer dia .Pipes.


20 mm nominal outer dia .Pipes.
Providing and fixing Chlorinated Polyvinyl Chloride
(CPVC) pipes, having thermal stability for hot & cold
water supply including all CPVC plain & brass threaded
fittings i/c fixing the pipe with clamps at 1.00 m spacing.
This includes jointing of pipes & fittings with one step
CPVC solvent cement and the testing of joints complete
as per direction of Engineer in charge.
Internal work - Exposed on wall

Item
No.
3.1
3.2
3.3
3.4
3.5

DSR Item
No.
DSR 18.7.2
DSR 18.7.3
DSR 18.7.4
DSR 18.7.5
DSR 18.7.6

4.1

5.2
5.3
5.4
5.5
5.6

Unit

Quantity

Rate (in
Rs.)

Amount in (Rs)

Metre

50.00

115.65

5782.50

Metre

75.00

150.40

11280.00

Metre

60.00

196.35

11781.00

Metre

45.00

275.05

12377.25

Metre

35.00

418.50

14647.50

Each

20.00

385.90

7718.00

25 mm nominal bore

Each

10.00

285.50

2855.00

32 mm nominal bore

Each

10.00

358.00

3580.00

Each

5.00

399.00

1995.00

Each

5.00

578.20

2891.00

Each

6.00

831.75

4990.50

Each

4.00

1369.25

5477.00

Metre

30.00

1217.80

36534.00

Metre

65.00

1590.75

103398.75

Each

2.00

8528.75

17057.50

Each

2.00

1282.10

2564.20

Each

2.00

1467.95

2935.90

Each

2.00

1812.25

3624.50

Each

2.00

2390.70

4781.40

Each

1.00

2448.40

2448.40

Each

1.00

3719.80

3719.80

20 mm nominal outer dia .Pipes.


25 mm nominal outer dia .Pipes.
32 mm nominal outer dia .Pipes.
40 mm nominal outer dia .Pipes.
50 mm nominal outer dia .Pipes.
Providing and fixing ball valve (brass) of approved
quality , high or low pressure, with plastic floats complete

DSR
18.18.3

5
5.1

Description of Item

25 mm nominal outer dia .pipes


Providing & fixing gunmetal gate valve with CI wheel of
approved quality (screwed end);

DSR
18 17 1
DSR
18 17 2
DSR
18.17.3
DSR
18.17.4
DSR
18.17.5
DSR
18.17.6

40 mm nominal bore
50 mm nominal bore
65 mm nominal bore
80 mm nominal bore
EXTERNAL WATER SUPPLY

Providing and fixing Chlorinated Polyvinyl Chloride


(CPVC) pipes, having thermal stability for hot & cold
water supply including all CPVC plain & brass threaded
fittings. This included jointing of pipes & fittings with one
step CPVC solvent cement, trenching, refilling & testing
of joints complete as per direction of Engineer in Charge
External work

6.1
6.2

DSR 18.9.7
DSR 18.9.8

7.1

8.2
8.3
8.4

DSR
18.35.1

9.2

With F.P.S. bricks


Providing and fixing GUN METAL NON-RETURN
VALVE of approved quality (screwed end)

DSR
18.19.5.1
DSR
18.19.5.2
DSR
18.19.6.1
DSR
18.19.6.2

9.1

75 mm nominal inner dia .Pipes.


Constructing masonry Chamber 120x120x100 cm, inside
with 75 class designation brick work in cement mortar
1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I.
surface box 100 mm. top diameter, 160 mm bottom
diameter and 180 mm deep ( inside) with chained lid and
RCC top slab 1:2: 4 mix ( 1 cement: 2 Course sand: 4
graded stone aggregate 20mm nominal size) necessary
execavation foundation concrete 1:5:10 ( 1 cement: 5
Fine sand: 10 graded stone aggregate 40mm nominal
size) and inside plastering with cement motar 1:3 (1
Cement: 3 Course Sand) 12mm thick finished with a
floting coat of neat cement complete as per standard
design:

8
8.1

62.50 mm nominal inner dia Pipes.

65 mm nominal bore - Horizontal


65 mm nominal bore - Vertical
80 mm nominal bore - Horizontal
80 mm nominal bore - Vertical
Providing and fixing enclosed type water meter (bulk
type) conforming to IS : 2373 and tested by Municipal
Board complete with bolts, nuts, rubber insertions etc.
(The tail pieces if required will be paid separately) :

DSR
18.60.1
DSR
18.60.2

80 mm dia nominal bore


100 mm dia nominal bore

Item
No.

DSR Item
No.

9.3

DSR
18.60.3

10

Description of Item

150 mm dia nominal bore

DSR
18.61.1

80 mm dia

10.2

DSR
18.61.2

100 mm dia.

11

Quantity

Rate (in
Rs.)

Amount in (Rs)

Each

1.00

5261.80

5261.80

Each

1.00

3110.45

3110.45

Each

1.00

4672.20

4672.20

1.00

6067.85

6067.85

20000.00

5.25

105000.00

metre

150.00

730.40

109560.00

metre

400.00

629.85

251940.00

each

25.00

65.35

1633.75

each

70.00

63.00

4410.00

each

50.00

291.00

14550.00

each

50.00

230.90

11545.00

each

25.00

489.60

12240.00

each

25.00

364.45

9111.25

each

30.00

637.10

19113.00

each

65.00

194.60

12649.00

each

65.00

177.45

11534.25

Providing and fixing C.I. dirt box strainer for bulk type
water meter with nuts, bolts, rubber insertions etc.
complete conforming to IS : 2373 :

10.1

10.3

Unit

150 mm dia
DSR
Each
18.61.3
DSR 18.48 Providing and placing on terrace (at all floor levels)
polyethylene water storage tank ISI : 12701 marked with
cover and suitable locking arrangement and making
litres
necessary holes for inlet, outlet and overflow pipes but
without fittings and the base support for tank.
INTERNAL DRAINAGE

12

Providing and fixing soil, waste and vent pipes :


Centrifugally cast (spun) iron socketed pipe as per IS:
3989.

12.1

DSR
17.35.1.2

100 mm dia.

12.2

DSR
17.35.2.2

75 mm dia.

13

13.1
13.2

Providing and fixing M.S. holder-bat clamps of approved


design to Sand Cast iron/cast iron (spun) pipe
embedded in and including cement concrete blocks
10x10x10cm of 1:2:4 mix (1 cement : 2 coarse sand : 4
graded stone aggregate 20mm nominal size) including
cost of cutting holes and making good the walls, etc
DSR
17.37.1
DSR
17.37.2

14

For 100 mm dia. Pipe


For 75 mm dia. Pipe
Providing and fixing bend of required degree with access
door, insertion rubber washer 3 mm thick, bolts and nuts
complete.
Sand cast iron S&S as per IS - 3989

14.1
14.2

DSR
17.38.1.2
DSR
17.38.2.2

15

100 mm
75 mm
Providing and fixing single equal plain junction of
required degree with access door, insertion rubber
washer 3 mm thick, bolts and nuts complete.
Sand cast iron S&S as per IS - 3989

15.1
15.2

DSR
17.43.1.2

100x100x100 mm

DSR
17.43.2.2

75x75x75 mm

16

16.1

Providing and fixing single unequal junction of required


degree with access door, insertion rubber washer 3 mm
thick, bolts and nuts complete :
Sand cast iron S&S as per IS - 3989
DSR
17.47.1.2

17

100x100x75 mm
Providing and fixing terminal guard:
Sand cast iron S&S as per IS - 3989

17.1
17.2
18

DSR
17.56.1.2
DSR
17.56.2.2

100 mm
75 mm
Providing lead caulked joints to sand cast iron/
centrifugally cast (spun) iron pipes and fittings of
diameter:

Item
No.

DSR Item
No.

18.1

DSR
17.58.1

100 mm

18.2

DSR
17.58.2

75 mm

19

19.1
19.2

Description of Item

Unit

Quantity

Rate (in
Rs.)

Amount in (Rs)

each

120.00

126.50

15180.00

each

120.00

107.80

12936.00

each

10.00

48.25

482.50

each

10.00

41.55

415.50

each

110.00

544.30

59873.00

each

110.00

573.35

63068.50

each

10.00

935.15

9351.50

each

16.00

11882.20

190115.20

Metre

35.00

3179.95

111298.25

Providing and fixing M.S. stays and clamps for sand cast
iron/ centrifugally cast (spun) iron pipes of diameter :
DSR
17.59.1

100 mm

DSR
17.59.2

75 mm

20

Providing and fixing trap of self cleansing design with


screwed down or hinged grating with or without vent arm
complete, including cost of cutting and making good the
walls and floors :

20.1

100 mm inlet and 100 mm outlet


DSR
17.60.1.1

Sand cast iron S&S as per IS: 3989.

DSR
17.60.2.1

Sand cast iron S&S as per IS - 3989

20.2

100 mm inlet and 75 mm outlet

EXTERNAL DRAINAGE
21

21.1
22

22.1

Providing and fixing square-mouth S.W. gully trap Class


SP-1 complete with C.I. grating brick masonry chamber
with water tight C.I. cover with frame of 300 x300 mm
DSR 19.4
size (inside) the weight of cover to be not less than 4.50
kg and frame to be not less than 2.70 kg as per standard
design :
100x100 mm size P type
DSR
19.4.1.1

With F.P.S. Bricks class designation 75

Constructing brick masonry manhole in cement mortar


1:4 ( 1 cement : 4 coarse sand ) R.C.C. top slab with
1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone
aggregate 20 mm nominal size), foundation concrete
1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone
aggregate 40mm nominal size) inside plastering 12mm
DSR 19.7 thick with cement mortar 1:3 (1 cement : 3 coarse sand)
finished with floating coat of neat cement and making
channels in cement concrete 1:2:4 (1 cement : 2 coarse
sand : 4 graded stone aggregate 20mm nominal size)
finished with a floating coat of neat cement complete as
per standard design :

DSR
19.7.2.1

23

Inside size 120x90 cm and 90 cm deep including C.I.


cover with frame (medium duty) 500 mm internal
diameter, total weight of cover and frame to be not less
than 116 kg (weight of cover 58 kg and weight of frame
58 kg) :
With F.P.S. bricks class designation 75
Extra for depth for manholes
Size 120x90 cm

23.1
24

DSR
19.8.2.1

With F.P.S. bricks class designation 75


Constructing masonry Chamber 120x120x100 cm, inside
with 75 class designation brick work in cement mortar
1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I.
surface box 100 mm. top diameter, 160 mm bottom
diameter and 180 mm deep ( inside) with chined lid and
RCC top slab 1:2:4 mix (1 cement :2 coarse sand : 4
graded stone aggregate 20 mm nominal size) necessary
excavation foundation concrete 1:5:10 (1 cement : 5 fine
sand : 10 graded stone aggregate 40 mm nominal size)
and inside plastering with cement mortar 1:3 (1 cement :
3 coarse sand) 12 mm thick finished with a floating coat
of neat cement complete as per standard design :

Item
No.

DSR Item
No.

24.1

DSR
18.35.1

25

25.1

Description of Item

With F.P.S. bricks

Unit

Quantity

Rate (in
Rs.)

Amount in (Rs)

each

2.00

8528.75

17057.50

each

2.00

9938.60

19877.20

Making soak pit 2.5 m diameter 3.0 metre deep with 45 x


45 cm dry brick honey comb shaft with bricks of class
designation 75 and S.W. drain pipe 100 mm diameter,
1.8 m long complete as per standard design.
DSR
19.32.1

With F.P.S. bricks


Total C/o to Summary : Rs.

1393953.15

CONSTRUCTION OF AUDITORIUM/CONVENTION CENTRE AT NASC COMPLEX, PUSA, NEW DELHI


PART-II (Non-Scheduled Items based on Market rates)
Item
No.
A
1

Description of Item

Unit

Wood, Iron and Steel Works


Supplying and fixing in position of stainless steel
handrail assembly complete in all respect fabricated
from 38 mm dia (2mm thick) stainless steel vertical
posts spaced at 900 mm centre to centre
approximately and welded to top with horizontal
stainless steel pipe of 60 mm dia (3mm thick) and
three rows of guard rail 25 mm dia (1.63 mm thick) metre
stainless steel pipe including welding at site, grinding
and polishing etc, complete ( SS 304 NICKEL 0.8%).
(for payment purpose only the running length of
handrail will be measured) [Carl F make or
equivalent]
Total C/o to Summary : Rs.

JOINERY WORKS
2hr. Fire rated hollow metal doors - Painted

Providing and fixing of Hollow metal fire rated doors


at all levels from ISO 9001-2000 certified
Manufacturer. Fire door should be as per IS 3614
part-1 & part-2 and BS 476 part 2 or EN 1634.
Recommended fire door shall be tested and certified
by a third party evaluation program from approved
international agency like CERTIFIRE and labled.
Where third party evaluation is not required fire doors
should be tested at CBRI or ARAI for maximum
rating of 2hrs both with vision panel and without
vision panel. Pressed Galvanized steel Single
/Double leaf door of approved make shakti met-dor
or approved equivalent which consists of frame,
shutter, infill and finish as detailed below and
conforming to IS 277.
Door frame shall be double rebate profile of size 143
x 57 mm made out of 1.60mm (16gauge) thick
galvanized steel sheet. Frames shall be Mitered and
field assembled with self tabs. All provision should
be mortised, drilled and tapped for receiving
appropriate hardware. Rubber door silencers should
be provided on the striking jamb. Frames should be
provided with back plate bracket and anchor
fasteners for installation on a finished plastered
masonry wall opening. Once frame installed should
be grouted with cement & sand slurry necessary for
fire doors on the clear masonry opening.
Door leaf shall be 46mm thick fully flush double skin
door with or without vision lite. Door leaf shall be
manufactured from 1.2mm (18guage) thick
galvanised steel sheet. The internal construction of
the door should be rigid reinforcement pads for
receiving appropriate hardware. The infill material
shall be resin bonded honeycomb core. All doors
shall be factory prepped for receiving appropriate
hardware and provided with necessary reinforcement
for hinges, locks, and door closers. The edges
should be interlocked with a bending radius of
1.4mm. For pair of doors astragals has to be
provided on the meeting stile for both active and
inactive leaf. Vision lite wherever applicable should
be of size 200x300mm provided as per
manufacturers recommendation with a beeding and
screws from inside. The glass should be 6mm clear
borosilicate fire rated glass of relavant rating of the
door with all fittings like hinges, locks, handels and
tower bolts
All doors and frames shall be finished with etched
primer coating, stove zinc phosphate primer and
thermosetting polyurethane aliphatic grade paint of
approved colour. The door leaf and frame shall
have passed minimum 250 hours of salt spray
test. as per requirement and direction of engineer
in charge. The detail hardware list is enclosed (in
technical specification in section - 3 )

Quantity

180.00

Rate in
Rate in words (in
figures (in
Rs.)
Rs.)

Amount (in Rs.)

Item
No.

Description of Item

2Hrs Fire rated door double leaf of size FD1 :


2000x2400mm with vision panel

Quantity

each

29.00

each

1.00

each

7.00

each

2.00

each

12.00

2Hrs Fire rated door double leaf of size FD2:


1500x2400mm with 200x300mm visionpanel

2Hrs Fire rated door double leaf of size FD2:


1500x2400mm with 200x300mm visionpanel

2Hrs Fire rated door double leaf of size FD1 :


2000x2400mm with 200x300mm visionpanel

2Hrs Fire rated door double leaf of size FD2 :


1500x2400mm 200x300mm with visionpanel

General doors - Painted


2

Unit

Providing and fixing of Hollow metal door at all levels


from ISO 9001-2000 certified Manufacturer. All
hollow metal general doors with or without vision
panel. Pressed Galvanised steel Single /Double leaf
to required sizes of approved make shakti met-dor or
approved equivalent which consists of frame, shutter,
infill and finish as detailed below and conforming to
IS 277.Door frame shall be single rebate profile of
size 100 x 57 mm made out of 1.20mm (18gauge)
thick galvanized steel sheet. Frames shall be Mitered
and field assembled with self tabs. All provision
should be mortised, drilled and tapped for receiving
appropriate hardware. Rubber door silencers should
be provided on the striking jamb. Frames should be
provided with back plate bracket and anchor
fasteners for installation on a finished plastered
masonry wall opening. Once frame installed should
be grouted with cement & sand slurry necessary for
fire doors on the clear masonry opening.
Door leaf should be 46mm thick fully flush double
skin door with or without vision lite. Door leaf shall be
manufactured from 0.8mm (22 guage) thick
galvanised steel sheet. The internal construction of
the door should be rigid with steel stiffeners/ pads
and reinforcement. The infill material shall be resin
bonded honeycomb core. All doors should be factory
prepped for receiving appropriate hardware and
provided with necessary reinforcement for hinges,
locks, and door closers. The edges should be
interlocked with a bending radius of 1.4mm. For pair
of doors astragals has to be provided on the meeting
stile for both active and inactive leaf. Vision lite
wherever applicable should be of size 200x300mm
& 150x750mm provided as per manufacturers
recommendation with a beading and screws from
inside. The glass should be 6mm thick clear float
glass. The door should be complete with
locks,Hinges,panic bar, door closers,door stoppers ,
handels, vision panels and tower bolts etc as per
requirement and direction of engineer in charge. The
detail hardware list is enclosed (in technical
specification in section - 3 )

Rate in
Rate in words (in
figures (in
Rs.)
Rs.)

Amount (in Rs.)

Item
No.

Description of Item

Unit

Quantity

Steel door single leaf of size: D3 1000x2400mm


without vision panel

each

Steel door single leaf of size: D4 900x2400mm


without vision panel

each

Steel door single leaf of size: D3 1000x2400mm


without vision panel

each

Steel door single leaf of size: D4 900x2400mm


without visionpanel

each

Steel door single leaf of size: D3 1000x2400mm


without visionpanel

each

Steel door double leaf of size: D2 1500x2400mm


with vision panel

each

Steel door double leaf of size: D2 1500x2400mm


without vision panel

each

Steel door double leaf of size: D6 1500x2400mm


with 200x300mm vision panel (Un Equal Shutter)

each

Steel door double leaf of size: D1 2000x2400mm


with 150x750mm vision panel

each

22

Steel door double leaf of size: D1 2000x2400mm


with 200x300mm vision panel

each

Steel door double leaf of size: D1 2000x2400mm


with 150x750mm vision panel

each

Steel door double leaf of size: D2 1500x2400mm


with 150x750mm vision panel

each

Steel door double leaf of size: D1 2000x2400mm


with 150x750mm vision panel

each

Steel door single leaf of size: D4 900x2400mm with


200x300mm visionpanel

each

All doors and frames shall be finished with etched


primer coating, stove zinc phosphate primer and
thermosetting polyurethane aliphatic grade paint of
approved RAL colour. The door leaf and frame
shall have passed minimum 250 hours of salt
spray test.
Rate should include supply and installation of door
and hardware set as mentioned in the door and
hardware schedule in the technical specifications
(Section-3)
a

Rate in
Rate in words (in
figures (in
Rs.)
Rs.)

Amount (in Rs.)

Item
No.

Description of Item

Unit

Quantity

Steel door single leaf of size: D3 1000x2400mm with


200x300mm visionpanel

each

Steel door single leaf of size: D3 1000x2400mm with


200x300mm visionpanel

each

Steel door single leaf of size: D4 900x2400mm with


200x300mm visionpanel

each

Steel door single leaf of size: D4 900x2400mm


without visionpanel

each

Steel door double leaf of size: D2 1500x2400mm


with 200x300mm vision panel

each

Steel door double leaf of size: D1 2000x2400mm


with vision panel

each

Steel door double leaf of size: D2 1500x2400mm


with 200x300mm vision panel

each

Steel door single leaf of size: D4 900x2400mm


without visionpanel

each

Steel door single leaf of size: D4 900x2400mm with


200x300mm visionpanel

each

Steel door single leaf of size: D3 1000x2400mm


without visionpanel

each

Steel door double leaf of size: D1 2000x2400mm


with 200x300mm vision panel

each

Steel door double leaf of size: D6 1500x2400mm


with vision panel (Un Equal Shutter)

each

Providing and fixing of Stainless Steel toilet partitions


and cubicles with doors and hardware for fixing and
mounting
of
the
panels
as
manufacture
specifications and by Approved vendor. The scope of
work includes complete in all respect and as per the
direction of Engineer in charge
Construction of cubicles : The panels should be
constructed for 25mm and doors for 22mm thick
sandwiched skin with the infill material of honey
comb core. The core should be bonded with resin
and should have a flat face on either side. All panels
should have a built in feature to be totally sight proof
on all four corners for better privacy. Standard gap of
150mm on sides and on the moving element has to
be provided unless otherwise specified. Cubicles
should have a provision for mounting of the toilet
hardware like handrails, hinges, locks with indicator,
coat hooks as specified. All panels should be fully
protected with the self adhesive film and to be
removed at the handing over of the cubicles.

Rate in
Rate in words (in
figures (in
Rs.)
Rs.)

Amount (in Rs.)

Item
No.

Description of Item

Unit

Quantity

Type : Floor Mounted with legs: The cubicles are


mounted on the Stainless Steel legs. Support bars
on top for stability and integrity which in turn is
connected to solid wall support. Wall brackets and
corner brackets to be used while assembling the
cubicles. In addition the door should have a selfclosing hinge and an indicator slip latch or bolt with a
knob outside.
Material / Finish / Hardware : A. All toilet partitions
and cubicles should be made out of first grade
stretched level quality Stainless Steel conforming to
SS304 grade. All products should be made out of
0.6mm (22g) Stainless Steel sheet.Door Hardware:
Heavy duty, Stainless Steel.
1. Top & Bottom Hinge: Surface Mounted, with
Stainless Steel pin in the plane of the door.2. Latch:
Surface mounted, with emergency access. 3. Coat
Hook and Bumper : Surface mounted 4. Wall
Brackets: For wall support and mounting the panels.
C. Legs should be made out of Stainless Steel as
specified. D. All support and locking accessories
should be Stainless Steel as specified.

Installation :All cubicles should be checked for


dimensional accuracy before start of installation. Any
variations in the agreed site conditions or civil
structure should be addressed before installing the
panels and doors. The internal fittings like WC
related works should be completed in all aspects
before the panels are positioned. All installation
Cubicle Size is 1800 MM X 1300 MM
each
Supplying and Fixing of Unplasticised Poly Vinyl
Chorlide (UPVC) Casement Window of approved
make, using UPVC reinforced profiles of required
sizes. The minimum wall thickness for the external
surfaces shall not be less than 2.5mm. The system
must have minimum 3 sealed chambers, for the
casement shutter and mullion section capable of
mountingsingle / double glazing system, structurally
reinforced with hot dip galvanized steel with 120GSM
of miniumum thickness of 1.8mm prefabricated and
welded through fusion welding. the window shall be
fitted with 5mm thick tinted / float glass of reputed Sqm
make duly fitted with EPDM weathering seal and
accesories likefriction stay hinges of stainless steel
grade 304-2Nos per sash, handle with with zamak
alloy casting 1 No per sash, multipoint locking
system suitably concealed 1 No per sash and the
system is to be installed at site using anchor
fasteners, silicon sealant, easy galzing / deglazing at
site etc., including cost and conveyance of all
material,
accessories,
labour
charges
for
transportation, erection at site complete for finished
item of work
Total C/o to Summary : Rs.

FLOORING WORKS

Providing and laying Vitrified Ceramic floor tiles 600


mmx 600 mm (thickness to be specified by the
manufacturer) of 1st quality conforming to IS :15622
of approved make in colours such as White, Ivory,
Grey, Fume Red Brown, laid on 20 mm thick Cement
Mortar 1:4 (1 Cement : 4 Coarse sand) including
pointing the joints with white cement and matching
pigment etc., complete.(IMOLA or its equivalent)

sqm

65.00

42.00

600.00

Rate in
Rate in words (in
figures (in
Rs.)
Rs.)

Amount (in Rs.)

Item
No.

Description of Item

Providing and fixing Ist quality ceramic vitrified wall


tiles conforming to IS : 15622 (thickness to be
specified by the manufacturer ) of approved make in
all colours, shades except burgundy, bottle green,
black of any size as approved by Engineer-in-Charge
in skirting, risers of steps and dados over 12 mm
thick bed of cement Mortar 1:3 (1 cement : 3 coarse
sand) and jointing with grey cement slurry @ 3.3kg
per sqm including pointing in white cement mixed
with pigment of matching shade complete. ( Size 600
MM X 300 MM ) IMOLA or its equivalent

1910.00

sqm

2520.00

sqm

500.00

Extra for providing and fixing 125 mm high skirting in


place of flooring with best quality approved colour
granite slab of thickness not less than 20 mm,
machine cut and machine high pre-polished set in
C.M 1:3, 12 mm thick uniformly beyond the backing
mortar / plastered surface and finishing the joints metre
with white cement slurry at all levels and all as
directed. Rate shall include for preparation of
surface, chasing of wall and acid cleaning, edge
chamfering and polishing.
Sadarahalli Grey/Steel grey
Total C/o to Summary : Rs.

sqm

Extra for providing and fixing step risers and treads


in place of flooring with approved colour granite
slab of thickness not less than 20 mm in single
piece for each step rounded or patterned as per
drawing over a bed of C.M 1:4, 20 mm thick, all
edges machine cut, machine polished including
cutting, Flame the Granite in the edges to a width of
25mm(Entrance steps), making groove to the
specified size in the edges( Staicase steps),
chamfering and edge polishing to rough,medium,
nice, acid wash and tin oxide polishing as per
manufacturers specification and as directed. Rate
shall include for preparation of base surface, jointing
with matching cement slurry, work at all levels etc
complete, all as directed by Engineer-in-charge.
Sadarahalli Grey/Steel grey

Quantity

Providing flooring with best quality approved colour


granite slab not less than 20 mm thick of size not
less than 1200 x 900 mm/ 900 x 600/ 600x600 mm,
machine cut with water ( without kerosene ) and
factory high pre-polished, set in cement mortar 1:4 to
a thick not less than 20 mm (for surface contact of
the bottom of the granite slab) as per approved
pattern/design using irrespective of size and shape,
including finishing the joints with Cement Slurry
and cutting, edge chamfering and polishing with tinoxide / high gloss factory polish as per
manufacturer's Specification and as directed.
Grinding after laying for level adjusment shall not be
permitted.
Rate shall include for preparation of base surface &
finished the surface, protection with gypsum/pop
layer over plastic sheet and removing the same
before handing over,work at all levels and as
directed by Engineer-in-charge.

Unit

BARICADING WORKS

1440.00

Rate in
Rate in words (in
figures (in
Rs.)
Rs.)

Amount (in Rs.)

Item
No.
1

Description of Item

Unit

Providing,
supplying and fixing temporaray
barrication with GI sheet at all height up to 3.0m and
soft partition with green fibre cloth up to 17.0M for
the entire width of the proposed extension side
providing temporary barication around the proposed
construction with necessary GI sheet, MS Pipe
vertical and horizontal supports with holding clamps ,
Sqm
temporary barigator shall be removed after
completinon of project or as per directed by the
client. the entire structure to abide all the safety
regulations. contractor to ensure adequate size of
support member to ensure total safety of barication
for the entire duration of project
Total C/o to Summary : Rs.

Quantity

4500.00

Rate in
Rate in words (in
figures (in
Rs.)
Rs.)

Amount (in Rs.)

Item
No.

Description of Item

Unit

GLAZING WORKS

Unitized structural glazing (for complete system) :Prepration of shop drawing, detailing providing and
fixing Unitized structural glazing system with
vision panel and vision on spandral panel shall have
Insulated Glazed unit - 24 mm thick (6mm glass + 12
mm airgap+ 6mm glass) of approved make and as
specified and work shall be completed as per Sqm
direction of engineer in charge. Rate including
fixing the glass but excluding cost of supply of
glass which will be measured separately. (REFER
DETAILS AT SECTION -3 TECH SPECS)
INCLUDING FRAMES, SECTIONS ETC...

Punched window/Strip window (System): for


complete system prepration of shop drawing,
detailing, providing and fixing Unitized structural
glazing system with Punched window / Strip
window either on the same plane of the unitized
structural glazing system or recessed as per drawing
with Insulated Glazed unit - 24 mm thick (6mm glass
Sqm
+ 12 mm airgap+ 6mm glass) of approved make and
as specified and work shall be completed as per
direction of engineer in charge. Rate including
fixing the glass but excluding cost of supply of
glass which will be measured separately. (REFER
DETAILS AT SECTION -3 TECH SPECS)
Hardwares for Top hung windows: Extra rate over
& above the structural glazing item above for
providing top hung openable outward shutter of size
as shown in the approved drawing and to be
provided and fixed on the same plane of the
Each
Unitised structural glazing system with same
set
shade & make of glass with the specified hardwares
excluding the cost of Insulated glazed unit specified
and work shall be completed as per direction of
engineer in charge.(REFER DETAILS AT SECTION 3 TECH SPECS)
Insulation for Spandrel: Rock wool slab - 64
Kg/cum and having 'K' value of 0.033 w/Mok - 50 mm
thick wrapped with factory pressed Black glass tissue
and using 1.0mm thick powder coated G.I tray with
fold alround to a height of 100mm minimum as
thermal insulation to be fixed behind Composite Sqm
panel cladding area as mentioned. All the edges
between powder coated M.S tray and frame to be
sealed with Non-Staining weather silicon sealant of
approved make.(REFER DETAILS AT SECTION -3
TECH SPECS)

Swing / Openable door :


complete system for the openable door with patch
fittings. Providing and fixing the openable Double /
Single leaf door with patch fittings. Rate shall include
the cost for supplying and fixing of laminated glass
12.52 mm thick and having 6 mm thick as outer
panel and 5 mm thick as inner panel with interlayer
of 1.52 mm thick PVB - santry Glass plus of Dubond
make. Both outer and Inner pane shall be uncoated
clear glass of Saint Gobain or Asahi make and both
panes shall be toughened, supply & fixing of
hardwares and necessary accessories etc.. (REFER
DETAILS AT SECTION -3 TECH SPECS)
INCLUDING FRAMES, SECTIONS ETC...

Double Leaf door as per the details above.

Sqm

Quantity

1,360

50

20

1,360

70

Rate in
Rate in words (in
figures (in
Rs.)
Rs.)

Amount (in Rs.)

Item
No.
6

Description of Item

Unit

Fixed window system using WCP/ 'U' channel:


Fixed window system: designing, providing and
fixing "fixed window system" having laminated glass 13.52 mm thick of approved make. Rate includes
supplying and fixing the laminated glass 13.52 mm
thick and having 6 mm thick as outer panel and 6
mm thick as inner panel with interlayer of 1.52 mm
thick PVB - santry Glass plus of Dubond make. Outer
pane glass shall be reflective coated glass - Sunergy Sqm
Clear of Asahi make or ST 167 of Saint gobain
make. Inner pane shall be uncoated clear glass and
both panes shall be toughened and heat soak tested
and continuous WCP at top and Aluminium 'U'
channel at bottom etc.. (REFER DETAILS AT
SECTION -3 TECH SPECS) INCLUDING FRAMES,
SECTIONS ETC...
Supply of glass

500

Glass for Structural Glazing system complete: Supply


of glass as per the options given below to the
respective place to fix the glass on the system as
described in Technical specification. Fixing the glass
shall form part of the system and shall include in the
cost quoted under respective item. Refer Technical
specification for the glass performance, processing,
thickness and coating of glass, tint and other
parametres like heat treatment process etc. All
panes of glass shall be heat strengthened.
Mode of Measurement :
Glass on structural Glazing & others : Length and
breadth of the superficial area of the finished work
shall be measured centre to centre of the grooves on
the external surface viewed externally correct to a
centimetre under the respective items. Areas shall
be calculated in a square metre correct to two places
of decimal. (REFER DETAILS AT SECTION -3
TECH SPECS) ETC...
Vision Panel & Spandrel Panel : Insulated Glass 24 mm thick with 6 mm thick Reflective coated glass
on both surface - ET 725 of Saint Gobain or
equivalent as outer pane and 12 mm airgap and 6
mm thick uncoated clear glass as inner pane of Sqm
same make. Both panes are heat strengthened. Rate
exclude fixing of glass, fixing of glass shall form part
the system cost quoted. The glass will be selected at
appropriate time by Client / Architect.

Quantity

Vision Panel & Spandrel Panel : Insulated Glass 24 mm thick with 6 mm thick Reflective coated glass
on both surface - SKN 744 of Saint Gobain or
equivalent as outer pane and 12 mm airgap and 6
mm thick uncoated clear glass as inner pane of
same make. Both panes are heat strengthened. Rate Sqm
exclude fixing of glass, fixing of glass shall form part
the system cost quoted. The glass will be selected at
appropriate time by Client / Architect. . ( REFER
DETAILS AT SECTION -3 TECH SPECS)

1,410

10

Laminated sandwiched composite panel (ACP)


cladding system
Providing, supplying, fixing complete system (Dry
wall cladding) including providing and fixing the
system to clad the Aluminium composite panel (ACP
with Mineral Core) as per the specification on the.
external surface the external surface like column,
Sqm
wall, jambs, sills, projected area, ceiling or any
surface to any profile and shape, horizontally,
vertically, sloped, curved, circular etc complete.
(REFER DETAILS AT SECTION -3 TECH SPECS)
INCLUDING FRAMES ,SECTIONS ETC...

2,800.00

Rate in
Rate in words (in
figures (in
Rs.)
Rs.)

Amount (in Rs.)

Item
No.
10

11

12

Description of Item

Unit

Providing, supplying, fixing complete system


including providing and fixing Aluminium composite
panel (ACP with Mineral Core) to clad the external
surface of the Canopy, screen wall and Pergola as
per profile and shape shown in the Drawing with
necessary Hot dip Galvanised Structural steel
support to clad the ACP and all support to be
designed to withstand the Design wind pressure and
the specification specified above etc complete. Base Sqm
support will be measured under respective item
separately.
NOTE :- Base structural steel frame work for ACP
cladding covered under this item shall be measured
separately under the respective Item, but the frame
work required for cladding shall be part Items rate
quoted in this items. (REFER DETAILS AT
SECTION -3 TECH SPECS) INCLUDING FRAMES
SECTIONS ETC
providing and applying Cold Bituminous coating
(Vapour barrier) on the External wall behind
Composite panel cladding area etc as mentioned. Sqm
(REFER DETAILS AT SECTION -3 TECH SPECS)
providing and fixing in position Hot rolled structural
steel Members / Sections at all levels. (REFER
DETAILS AT SECTION -3 TECH SPECS)
INCLUDING FRAMES, SECTIONS ETC

Kg

Quantity

100.00

2,820

25

Total C/o to Summary : Rs.


F

Insulation, Granite Cladding


Insulation

Providing and fixing Rock wool - 50 mm thick - 64 Kg


/ cum and having K value of 0.023 w / M deg k of
approved make conforming to IS - 8183 / BS 3958 /
ASTM C 612 on the spandrel panel area i.e, behind
the ACP / glass and for smoke seal at sill level.
These wool should be covered with Black tissue
factory pressed - 0.50 mm thick (Nominal Mass - 60
Kg/cum) to conform Non combustibility Class - fire
rating to BS 476 - part 7 & IS 3808 and fixed by using
GI Angle / channel of required size as base and the
wool shall be tied with 22 gauge G.I. wire in crisscross manner into Galvanised angle / Channel to Sqm
the structure and shall be covered with powder
coated M.S sheet 1mm thick. Rock wool should be
fixed to the main aluminium frame work between
mullion & transom on each side with the gap of 25 to
30 mm from the inner surface of the Glass/ACP (i.e
behind the spandrel panel glass / ACP area / stone
cladding). Insulation tray shall be fixed in between
the transoms & mullions and tray shall have fold on
all 4 sides to the extend of 75mm on all 3 sides and
100 mm at bottom.

110.00

Rate in
Rate in words (in
figures (in
Rs.)
Rs.)

Amount (in Rs.)

Item
No.

Description of Item

Unit

Quantity

Granite Cladding
1

Providing and fixing Granite slab - Dry type fixing


using approved colour granite slab (Basic cost of
Granite not less than Rs.200/- per sq.ft) thickness as
specified in Schedule of Quantities and size as per
drawing subject to the size of slab is not less than
600x600 mm to the maximum extent. Rate shall
include providing smaller size of granite if
necessitated to form a Patten or at corners and no
extra cost is payable, if any additional cutting,
polishing is involved. Each granite slab is to be
individually supported using 4 Nos.of stainless steel
clamps of size 75 x 50 x 5 mm two each at top and
bottom with necessary SS screws & bolts and all SS
shall be 300 series - 316 Grade. Each SS clamp will
be fixed to the wall using two numbers of MS
oxidized non-corrosive expansion anchor fasteners
of size 10 mm head, 6 mm dia. and 100 mm length
for masonry work , 10 mm head, 6 mm dia. and 75
mm length for RCC areas. SS clamps with the
lipping of 12 mm height shall be fixed into the Granite
at the top & bottom in the cut groove on the granite
with groove cut is being 20mm long, 8mm wide.
Any corner or junction slab which may be of smaller
size should also be supported similarly. Each slab
will also have similar 2 clamps at the top, balance
gaps in the grooves after placing the Clamps in the
granite shall be filled with suitable adhesive of
approved make to ensure that the clamps are fixed
stable and not loosened. There will be no gaps seen
between the granite slabs in elevation or provide 3
mm Gap between the Granite slabs as directed. All
the edges of the Granite slab shall have "V" cut or
Half / Full round chamfered finish both horizontal and
vertical joints. It has to be ensured that the slabs are
perfectly vertical and in plumb. Gaps between the
granite slabs are to be filled with clear silicone non
staining sealant of approved make and all as per
manufacturer specifications. Rate shall include
providing the Granite slab matching the groove /
elevation lines to close the gaps on the top and sides
to prevent water or any insects coming through the
gap between wall and Dry fixing Granite.
Rate shall include for using the water cut Granite
slab (Kerosine cut not permitted either at factory or at
site), procuring the Granite from well recognized
approved quarry / suppliers with control over quarry
and mixing of quarry / suppliers for same shade
shall not be permitted under no circumstances and
also to be ensured that the shade of Granite
procured from single source will be uniform and no
colour or pattern variation and charges for groove
cutting in granite to fix SS clamps, Chamfering, edge
polishing, fabrication and fixing of SS clamps, anchor
fasteners, double scaffolding to the required heights,
wastages, work at all levels and heights, cleaning the
surface, protection of the Granite slab from any
damage till taken over by the Employer including
designing the entire system to withstand the design
wind pressure as desired by the Structural engineer
etc complete.

Cladding the external surface like column, wall,


jambs, sills, projected area or any surface to any
profile and shape, horizontally, vertically, sloped,
curved, circular etc with Granite slab - not less than
25 mm thick of approved colour with the size Sqm
matching to the Structural glazing line as shown in
the Drawing and providing the Granite slab on the
same plane of the Structural Glazing system etc
complete and as directed.
Total C/o to Summary: Rs.

20.00

Rate in
Rate in words (in
figures (in
Rs.)
Rs.)

Amount (in Rs.)

Item
No.

Description of Item

Unit

PLUMBING AND SANITATION

Providing , fixing, testing and commissioning of white


vitreous china glazed wall mounted type water
closet (European type) of approved make
conforming to IS 2556-Part 16 with seat cover and
CP brass hinges and rubber buffers, complete with
Concealed
flushing
cistern
with
push
button,complete with supply of necessary fittings,
supporting bolts /CI / MS brackets flushing pipe with
fittings and clamps, overflow arrangementand angle
cock of approved make and finish,together with cp
conncetion pipe to the cistern etc cutting and
making good the walls and floors wherever required
all complete as per specification and direction of the
Engineer-in-Charge. ( FOR VVIP/VIP /GREEN
ROOM )
WALL HUNG MODELS FROM (ROCA / DURAVIT /
TOTO)
each

15.00

Soft Close seat cover Models from ( ROCA /


DURAVIT / TOTO)
Providing , fixing, testing and commissioning of white
vitreous china glazed free standing type water
closet (European type) of approved make
conforming to IS 2556-Part 16 with seat cover and
CP brass hinges and rubber buffers, complete with
integral flushing cistern (dual flush)with lid,complete
with supply of necessary fittings, supporting bolts /CI
/ MS brackets flushing pipe with fittings and clamps,
overflow arrangementand angle cock of approved
make and finish,together with cp conncetion pipe to
the cistern etc cutting and making good the walls
and floors wherever required all complete as per
specification and direction of the Engineer-in-Charge.
Free Standing WC ( ROCA / DURAVIT / TOTO)

Quantity

Each

Seat cover Models from ( ROCA / DURAVIT /


TOTO)
Supplying, Installing, testing and commissioning of
White color Floor Mounted European water closet
with inbuilt low level flushing cistern and Wash
Basin for Physically Challenged Persons (Matrix)
with necessary Grab Rails, hinged rails for support ,
pan connecter bend,checknut, stopcock etc., colour
solid seat and cover with polythene buffer and flap,
CP flanges, CP bolts and nuts, bracket with nuts and Each
bolts wall flanges etc.,complete, Wash Basin shall
include 15mm dia CP liver operated pillar Cock with
waste coupling, 32mm dia CP bottle trap with
extension pipe,supporting bracket with necessary
steel to support basin 1 No.15mm CP angle valve
with 450mm long CP connection pipe and CP wall
flanges all of approved make etc., complete.

57.00

6.00

(ROCA / DURAVIT / TOTO)


4

Providing , fixing, testing and commissioning of


White color Wash basin size 500x380mm(below
counter ) type with 32mm dia CP waste coupling,
32mm dia CP bottle trap with extension pipe, pair of
stainless steel bolts,with bracket (MS /CI ) to support
to the basin, 15mm CP angle valve with CP inlet
connection tube , CP wall flange, including
necessary brakets etc complete (For VIP/VVIP and
Green Room)
UNDER COUNTER BASIN 500 X 380MM From
(ROCA / DURAVIT / TOTO)
Each
Sensor
faucet/
basin
mixer
(ROCA/
TOTO/GROHE)
Waste Coupling (Jaguar/ROCA/TOTO /GROHE)
CP bottle trap-(Jaguar/ROCA/TOTO/GROHE)

18.00

Rate in
Rate in words (in
figures (in
Rs.)
Rs.)

Amount (in Rs.)

Item
No.

Description of Item

Providing , fixing, testing and commissioning of


White color Wash basin size 500x380mm(below
counter ) type with 32mm dia CP waste coupling,
32mm dia CP bottle trap with extension pipe, pair of
stainless steel bolts,with bracket (MS /CI ) to support
to the basin, 15mm CP angle valve with CP inlet
connection tube , CP wall flange, including
necessary brakets etc complete
UNDER COUNTER BASIN 560MM X 420 MM
(ROCA/DURAVIT/ TOTO/)

Unit

Quantity

Each

62.00

Each

20.00

MONOJET single lever mono block basin mixer with


Pop-up (ROCA/ TOTO/GROHE)
Waste Coupling(Jaguar/ROCA/TOTO/GROHE)
CP bottle trap-(Jaguar/ROCA/TOTO/GROHE)

Supplying,installing,testing and commissioning of


bib cock for common areas, kitchen including
necessary accessories etc.complete.
Bib Cock(Jaguar/ROCA/TOTO/GROHE)

Providing, fixing ,testing and commissioning of


Urinal with integrated electronic flushing system
(sensor) ,integrated spreader, bottle trap, bottle trap
pipe, waste coupling, urinal waste pipe, one pair of
brackets, CP caps, unions etc. complete. the Item
Each
includes necessary fitttings for proper installations
etc. including chasing and making good the
walls,and floors wherever required all complete as
per specification and direction of the Engineer-inCharge.
Urinal sensor Model from (ROCA/ TOTO/GROHE)
CP bottle trap-(Jaguar/ROCA/TOTO/GROHE)
Providing, fixing ,testing and commissioning of
Urinal with integrated spreader bottle trap, bottle trap
pipe, waste coupling, urinal waste pipe, one pair of
brackets, CP caps, unions and urnial auto closing
push cock etc. complete. the Item includes
Each
necessary fitttings for proper installations etc.
including chasing and making good the walls,and
floors wherever required all complete as per
specification and direction of the Engineer-inCharge.
Flat back Large urinal (ROCA/DURAVIT/ TOTO/)
CP bottle trap(Jaguar/ROCA/TOTO/GROHE)

30.00

80.00

CP urinal valve auto closing system with built-in cockPressmatic taps (Jaguar/ROCA/TOTO /GROHE)
9

Supplying , fixing best quality mirror of approved


make of size 600 mm x 450 mm ,'thickness 6mm
fixed in plastic frame, colour 'matching with tiles
above the wash basin fixed to 6mm thick ply
woodsheet with CP hooks.complete with CP screws.
(The frame shall be approved the Engineer in
charge)

10

Each

80.00

Supplying , fixing in position and testing C.P. health


faucet with wall hook one metre long flexible tube,
angle cock with wall flange all complete including Each
cutting and making good the walls wherever
required.

78.00

CP Health Faucet (ROCA /TOTO/Grohe/Jaguar)


Angle Cock
11

Providing and fixing CP exposed type Toilet paper


holder with necessary screws etc.,

Each

78.00

Rate in
Rate in words (in
figures (in
Rs.)
Rs.)

Amount (in Rs.)

Item
No.

Description of Item

Toilet paper holder with Flap


/Grohe/Jaguar)
12

Unit

Quantity

Each

78.00

(ROCA /TOTO

Supplying and fixing CP Double Coat hook fixing


with necessary screws etc., complete

CP Double Coat hook (ROCA /TOTO /Grohe/


Jaguar)
13

Providng and fixing 600mm long CP towel rail


complete with brackets fixed to wooden cleats with
CP brass screws with concealed fitting arangement Each
of approved quality colour and make.
Towel Rail 600
/Grohe/Jaguar)

14

mm

long

(ROCA

80.00

/TOTO

Providing and fixing


liquid soap container of
approved
make
near
wash
basins
with
Each
necessaryfixing screws and clamps etc., complete.
(ROCA /TOTO /Grohe/Jaguar)

80.00

INTERNAL WATER SUPPLY


15

Providing and fixing ball valve (brass) of approved


quality , high or low pressure, with plastic floats
complete
a 32 mm nominal outer dia .pipes
Each

20.00

Each

10.00

Each

10.00

Each

1.00

b For 20mm dia (ID)-CPVC pipe:22mm(ID)10mm


thickness insulation
RMT

60.00

c For 25mm dia (ID)-CPVC pipe:32mm(ID)10mm


thickness insulation
RMT

60.00

d For 32mm dia (ID)-CPVC pipe:42mm(ID)10mm


thickness insulation
RMT

60.00

b 40 mm nominal outer dia .pipes

c 50 mm nominal outer dia .pipes

EXTERNAL WATER SUPPLY


16

Supplying,fixing of RB make Brass 'Y' strainer on


delivery line etc., complete
65mm dia

a Supplying and wrapping Vidoflex insulation for hot


water line in inside toilet, running in terrace&vertical
etc., complete

17

Supplying and fixing Hitech pipe supports including


required size of rail, no of rail legs grouting / anchor
fastners type,bolts,washer and nuts, Fixed in shaft ,
suspended in ceiling and terrace etc.complete

1.6 x 300 STD/HTWB with two legs

Each

15.00

Each

15.00

Each

15.00

1.6 x 500 STD/HTWB with two legs

1.6 x 600 STD/HTWB with two legs

Rate in
Rate in words (in
figures (in
Rs.)
Rs.)

Amount (in Rs.)

Item
No.
d

18

19

Description of Item

Unit

Quantity

Each

15.00

Each

15.00

Each

15.00

2000lit.capacity Solar Water heater- Flat Plate


Colector model (Copper tube)-Temp-60 degree Each
celcius.(For Normal Temperature)

2.00

2 x 1000 STD/HTWB with two legs

3 x 1800 STD/HTWB with two legs

3x 2000 STD/HTWB with two legs

Supplying,instaling,testing and commissioning of


Solar Water Heater of Tata BP make or equivalent
in quality and specification and as per direction
of Engineer in charge- Flat plate collector model.
An insulated storage tank is also to be provided for
collecting hot water.Electrical back up is also to be
provided. Works including loading the solar heater
panel and tocesories,locating very near of water tank
in terrace floor and making good to the inlet and
outlet connections including cost and conveyance of
all materials to the site, all labour charges, all taxes
etc., complete as directed by the Engineer InCharge.

Supplying and erection of power horizontal \


vertical centrifugal pump set of approved make
with all accessories including fixing and jointing
cable with proper clamp upto the starter to required
depth and also fixing of riser pipes to the required
depth, valves, erection clamps, pressure guages
upto exterior wall of pump room and erection of
panel consisting of TPICN switches, starter,
volumeter,ammeter, three pilot(indicator) lamps,
capacitor, single face preventer, water level guard
and laying and jointing the cable and twin earthing
as per IE rules, etc., complete and testing the pump
set etc. (The contractor has to give the suitable
design calculation for selecting the pump)
Discharge 12 lit / sec Head 40mt (1W+1S)
Each

20

21

INTERNAL DRAINAGE
Supplying,fixing and testing of Urinal trap (Sealed
Trap) used in sunken floors 110mm dia extension
boss tee arrangements with female thread fix with
each
the Staninless steel/upvc clean out plug in male
thread with gascet and three ss screws for urinals,
etc., complete
Supplying,fixing and testing of UPVC floor clean out
used in sunken floors, 75 or 110mm dia extension
boss tee arrangements with female thread fix with
each
the upvc clean out plug in male thread with gascet
and three ss screws for sunken floors etc. complete

2.00

50.00

60.00

EXTERNAL DRAINAGE
22

Providing fixing and testing UPVC SWR - B class


pressure rating 10 kg/sqm pipe of approved make
confirming to IS 13592-1992. and fittings confirming
to IS 14735-1999, such as coupler, elbow, bends,
tee, Y, vent cowl, etc for soil, waste, vent and rain
water pipe works in shaft and suspended in ceiling,
laid in ground (from shaft to inspection chamber and
gully chamber), etc. using rubber ring joints (rubber
ring confirming to IS 15382) for shafts lines and
solvent cement joints for suspended lines and work
in below ground. Works includes necessary
scaffolding, cutting and making good the walls
wherever required all complete as directed by EIC.
The quoted rate shall also necessary excavation
compaction and back filling, etc complete .
a) 160mm

Metre

120.00

Rate in
Rate in words (in
figures (in
Rs.)
Rs.)

Amount (in Rs.)

Item
No.

H
1

2
3

Description of Item

Unit

Quantity

Total C/o to Summary : Rs.


BORE WELL WORKS
Construction of tubewell by drilling 300mm dia bore
by DTH/reverse roratory or any other method in all
kind of soil, soft rock, hard rock etc. upto depth of
180mtrs.(ii) Supplying, lowering blind and slotted
200mm dia ERW-MS 5.4 mm th. pipe conforming to
IS:3589-i-1991(ISI marked) coated with anticoorosive black bitumastic paint, threaded and
socketed joining and welding including coat of alll
accesories, T&P required for job as per site
conditions including supplying/fixing 80mm dia GI
delivery pipe(50m long) medium class (Class-B)
conforming to IS:1239 of JINDAL/SWASTIK make
with all fittings and valves, flanges etc. compatible
cable, control panle with motor starter, incoming
main MCCB, voltmeter/Ammeter and making
connection with motor etc. complete (iv) Supplying,
shrouding andpacking of pea gravel alround the
annular space of casing pipe (v) Development of
borewell with high pressure compressor/OP unit till
the clean/sand free water supply obtained and
approved by the Engineer-in charge. (vi) Strata
sample drawn and preserved after 3 mtrs. of boring.
The samples shall be sent to approved laboratory for
physical, chemical and biological test. The result
achieved shall be as per the specifications &
satisfaction of Engineer-incharge (vii) Supplying &
fixing MS cap on 200 mm dia housing pipe as per
IS:226-1975, bail plug, clamps, centring guide &
handed over to the department. The work shall be
treated as completed only after the defect liability
period as decided by the concerned authority is over
Add or beyond or lessor depth instead of 180 mtr. Of
tube well as per the direction of Engineer incharge.

Job

1.00

mtr

10

each

2.00

Supplying and erection of power submersible


pumpset of approved make with all accessories in
borewell including fixing and jointing submersible
cable with proper clamps upto the starter to required
depth and also fixing of riser pipes to the required
depth valves erection clamps, pressure gauges upto
exterior wall of pump room and erection of panel
board consisting of TPICN switches starter,
volumeter, Ammeter, three pilot (indicator) lamps
capacitor single phasing preventor, water level guard
and laying and jointing the cables and twin earthing
as per IE rules etc, complete and testing the
pumpset and trail run for 10days(The contractor has
to give the suitable design calculation for selecting
the Pump.)
10LPS to a head of 160m to 200m

Total C/o to Summary : Rs.

Rate in
Rate in words (in
figures (in
Rs.)
Rs.)

Amount (in Rs.)

PART-II (Non-Scheduled Items based on Market rates (FIRE PROTECTION SYSTEM)


Item
No.

Description of Item

PUMPS, VALVES, ELECTRICAL PANELS & CABLES.

Unit

Quantity

No.

No.

No.

Nos.

ELECTRICAL DRIVEN PUMP

Supply, installation,
testing, commissioning
of
electrically driven pump set as per specification. Motor
TEFC type, 2900 rpm, 415V, 50 cycle frequency 3
phase class F insulation, I.P. 54 protection, 100 HP,
starting on DOL. The Pump shall be horizontal, end
suction, top discharge. The pump shall have cast iron
casing, bronze impeller, steel shaft with common base
frame capable of discharging 137 m3 per hour at 88 M
head.
DIESEL ENGINE PUMP
Supply,installation,testing,commissioning
of
diesel
engine driven pump set as per specification.The engine
should have RPM between 1800 to 2100.The Pump
shall be horizontal end suction, top discharge mounted
on common baseframe. Pump shall be directly coupled
to diesel engine of suitable HP as per system design
condition. Engine shall be complete with flywheel,
spider coupling, Air cleaners, Water cooled, Heat
Exchanger, Corrosion Resistor, Oil Sump with lube at
pump. Governor, Fuel Filter,Battery,Battery charger,
starting motor battery charging alternator & instrument
panel suitable for 24 volt DC including starting
switches,Diesel tank, lube oil temperature gauge,lube
oil pressure & high water temperature including flexible
exhaust connection.The pump shall be capable to
delivery 137m3/hr. at 88 M head.
JOCKEY PUMP:
Supply, installation, testing and commissioning of
electrically driven pump set as per specification. Motor
TEFC type, 2900 RPM 415 V, 50 cycles, 3 phase, class
F insulation, IP 54 protection, 20 HP starting on DOL.
The Pump shall be horizontal end suction top
discharge. The pump shall have cast iron casing, Cast
iron impeller, steel shaft.with common base frame
capable of discharging 10.8 m3/hour at 88 M head.
BOOSTER PUMP
Supply, installation, testing & commissioning of
electrically driven pumpset as per specification. Motor
TEFC type, 2900 RPM, 415 V 50 cycle, 3 phase Class
'F" insulation, IP - 55 protection, 15HP starting on DOL.
The Pump shall be horizontal, end suction, top
discharge. The pump shall be cast iron casing, bronze
impeller, steel shaft. with common base frame capable
of discharging 27 m3/hour at 45 m head. Pump to be
installed at Terrace.
MOTOR CONTROL CENTRE (MCC PANEL)
Supply installation testing and commissioning of
sectionalised cubicle type floor mounted front operated
dust and vermin proof power cum control panel made
out of not less than 1.6mm MS sheet with enamelled
finish i/c. one coat of primer of approved shade and
colour i/c. providing suitable number of switchgears,
busbars, auxilliary switches, audio alarm hooters, visual
indications, relays, contactors, timers of suitable
capacity for automatic operation of pumps i/c.
connections along with provision to link with IBMS and
all connected accessories.
Incoming
315A 4P,35KA MCCB with all other required
accessories - 2nos
1set of mechanical interlock(2 locks with 1 key)
arrangement
Instruments panel
Digital
type
ammeter,voltmeter,selector
switches,CTs,control fuses,one set of R,Y,B Indicating
lamps with control switches for common load side and
one set of ON/OFF/TRIP indicating lamp will protective
fuses for each incomer

Rate in
figures (in
Rs.)

Rate in words (in


Rs.)

Amount (in Rs.)

Item
No.

Description of Item

Unit

Quantity

No.

No.

Rmt.

30

Rmt.

350

Rmt.

30

Water level indicator and switch to prevent dry running


of fire pump i/c audio and visual alarm. 2x12V,18 AH
Lead acid battery for operating control panel.This shall
be independent of the engine starting battery and shall
remain trickle charged from common battery charger
status selector switch for each pump for automatic as
well as manual operation. Pumps when under manual
status shall be operated manually through relevant push
buttons.Lock out indication for electric fire pump as well
as audio alarm with silencing facility. Manual resetting
push button for return to normal operation of locked out
unit as reqd. Terminal facility for repeat indicator of
various audio and visual indications. 630A TPN
Aluminium busbars:All the neutral busbars shall have
the same capacity of phase busbars.
Outgoing
63A TP&N MCCB 25 KA with fully automatic DOL
Starter suitable for jockey pump with ON/OFF/TRIP
indicating lamps,ON/OFF push buttons and all other
required accessories -1No 160A TP&N MCCB 35 KA
with 75 HP fully automatic DOL starter with
ON/OFF/TRIP indicating lamps,ON/OFF push buttons
and all other required accessories-2Nos.32A TP&N
MCCB 25 KA with all other required accessories with
one set of ON/OFF/TRIP indicating lamp with protective
fuses-1 No, 63A TP&N MCCB 25 KA with fully
automatic DOL starter suitable for booster pump with
ON/OFF/TRIP indicating lamps ,ON/OFF push buttons
and all other required accessories -1No, With necessary
Aluminium busbars,interconnections, earthing etc.,with
required accessories as per specifications. Spare 63A
TP&N MCCB 25 KA with fully automatic DOL Starter
for pump with ON/OFF/TRIP indicating lamps,ON/OFF
push buttons and all other required accessories-1 no.
All indicating lamps shall be of LED type.Panel should
be powder coated.

DIESEL ENGINE AUTO START PANEL


Supply and installation of Autostart panel for the diesel
engine complete with auto/manual switch, indication
lamps protective fuses with battery charger, suitable of
working on 230 V, AC, single phase, enclosure being
vermin & dust proof. Also potential free conducts shall
be provided for connecting to the building automation
system
CABLES :
Supply, laying, testing and commissioning of the
following sizes of cables on surface of wall or cable tray

3.5C x 75 sq.mm XLPE Ins. Alu. armoured Cable


7.1

3.5C x 25 sq.mm XLPE Ins. Alu. armoured Cable


7.2

2 core X1.5Sq.mm PVC copper armoured cable


7.3

Rate in
figures (in
Rs.)

Rate in words (in


Rs.)

Amount (in Rs.)

Item
No.

Description of Item

Unit

Quantity

Rmt.

30

Rmt.

30

Nos

Nos

Nos

Nos

Nos

Rmt.

50

Rmt.

75

Rmt.

20

3 core X1.5Sq.mm PVC copper armoured cable


7.4
4 core X1.5Sq.mm PVC copper armoured cable
7.5

CABLE TERMINATION :
Supply termination and commissioning of the following
size cable double compression glands and crimping
socket with suitable earth clipp & fixing accessories.
3.5C x 75sq.mm XLPE Ins. Alu. armoured Cable

8.1
3.5C x 25 sq.mm XLPE Ins. Alu. armoured Cable
8.2
2 core X1.5Sq.mm PVC copper armoured cable
8.3
3 core X1.5Sq.mm PVC copper armoured cable
8.4
4 core X1.5Sq.mm PVC copper armoured cable
8.5
EARTHING :

Providing and fixing 6 SWG copper earth wire on


surface / recess for loop earthing as required.

Supply and laying 25 x 5 mm copper strip for Earthing of


the Electrical Motor MCC / Autostart Panel.
10

11

Suppling and fixing of cable tray 32 x 32 x 2 mm slotted


angle MS painted including anchor fasteners, supports
for wall and ceiling galvinsied Bolts and nuts etc

Rate in
figures (in
Rs.)

Rate in words (in


Rs.)

Amount (in Rs.)

Item
No.

Unit

Quantity

Nos.

Nos.

Nos.

No.

No.

Nos.

Nos.

Nos.

30

Nos.

Nos.

Nos.

Nos.

Nos.

Nos.

16

16

Supply & installation of 3Nos Differential Pressure


switch with 80NB Manifold, 150dia dial pressure gauge,
Bronze check valve with 2mm Orifice, Stainless Steel
presssure sensing piping 15mm dia required length as
shown in drawing.

Sets

17

Supply & installation of 20 mm dia CI Automatic Air


Release Valve to all wet risers all complete as per
specifications.

Nos.

20

12

Description of Item

Supply & Installation of Cast iron sluice valve including


making necessary flanged joints by providing necessary
nuts, bolts, gaskets, etc. all complete as per
specification
300 NB, PN 1.6 rating

12.1
200 NB, PN 1.6 rating
12.2
150 NB, PN 1.6 rating
12.3
100 NB, PN 1.6 rating
12.4
80 NB, PN 1.6 rating
12.5
65 NB, PN 1.6 rating
12.6
50 NB, PN 1.6 rating

13

Supply & installation of Cast Iron Butterfly Valves


including matching flanged joints by providing
necessary nuts, bolts, gaskets (1.5 mm CAF) etc. All
complete as per specifications.
150NB

13.1
65NB
13.2
50 NB
13.3

14

Suplying & installation of Cast Iron Non-Return Valves


including making flanged joints by providing necessary
nuts, bolts, gaskets etc. All complete as per
specifications.
150NB

14.1
50NB
14.2
15

Providing & installation of gunmetal gate valve having


screwed ends
65 NB.

15.1
50 NB.
15.2

Rate in
figures (in
Rs.)

Rate in words (in


Rs.)

Amount (in Rs.)

Item
No.

18

Description of Item

Unit

Quantity

Under Ground piping - Supply, erection, testing and


installation of MS pipes conforming to IS 3589 for
200NB & above and IS 1239 Class 'C' MS pipes for
150NB & below with welded joints including cutting the
pipes to correct length, providing and welding flanges to
pipe, fixing with clamps to MS brackets/ hangers,
making flanged joints with necessary nuts, bolts,
gaskets,. blank flanges, etc. Rates including 10%
radiograph all complete as per specifications of the
following diameters.

150 NB - Class C

Rmt

550

80 NB - Class C

Rmt

15

19

For above Ground pipe: Supply, fabrication &


installation of Class 'C' MS black pipe confirming to IS
1239 including cutting, welding MS flanges fixing in
pump room and yard and wherever necessary nuts,
bolts, gaskets. Rates inclusive of heavy class fittings,
steel suppots with painting, anchor bolts, hitec supports,
clamping etc as per specification.Rate shall be inclusive
of Zinc chromate primer over that 2 coats red enamel
panit as per Fire authorities requirement for above
ground pipes.

400 NB - 6 mm thick

Rmt

10

300 NB - 6 mm thick

Rmt

200 NB - 6 mm thick

Rmt

15

150 NB - Class C

Rmt

180

100 NB - Class C

Rmt

12

80 NB - Class C

Rmt

225

65 NB - Class C

Rmt

13

50 NB - Class C

Rmt

14

40NB - Class C

Rmt

25

Nos.

12

Nos.

12

Nos.

12

20

21

22

Supply, installation, testing and commissioning of


courtyard Gun metal Single headed hydrant as per IS:
5290 consisting of 63NB single outlet flanged oblique
type hydrants valve with instantaneous female plunger
type coupling, chained blank cap including making
flanged joints by providing necessary nuts, bolts,
gaskets all complete as per specifications.
Supply & installation of RRL type-A hose cabinet of
63mm dia. x 15 meters long with heavy quality gun
metal male coupling of IS: 903. combined with 2 Nos of
Canvass hoses and 1 No. of nozzle.
Supply&installation of fabricated 18SWG MS sheet of
size 750x600x250 with glass fronted door, with
sysnthetic enamel / with a coat of primer painted in red
out side and white in inside, hose boxes along with GI
support angles for courtyard hydrants. Each box shall
be capable to accommodate 2 hose each of 63 mm dia
x 15 m long hose pipe, nozzle, branch pipe etc.

Rate in
figures (in
Rs.)

Rate in words (in


Rs.)

Amount (in Rs.)

Item
No.

Unit

Quantity

Nos.

24

Nos.

24

25

Supply & Installation of drum type wall mounting hose


reels, swiveling 180o consisting of 25 mm dia. x 30
meters long armored rubber hose pipe with 15 mm dia.
bronze shut of type jet nozzle & cut-off valve on the inlet
including making connection to the wet riser, by drilling
welding, fixing the hose reel to the wall by providing
necessary anchor fasteners/ expansion bolts, grouting
the same with cement mortar, painting all complete as
per drawings, specifications.

Nos.

24

27

Supply & installation of Siamese inlet (Fire Brigade inlet)


connection with provision for Four male instantaneous
coupling fabricated out of 150 mm dia. approved make
heavy class MS pipe with non-return valve, for fire
fighting system including making connection by
providing necessary piping & fittings to the fire storage
tank, fire fighting wet riser, sprinkler system painting the
same with 3 coats of enamel paint over a coat of Zinc
Chromate primer all complete as per drawings,
specifications.Connection to Fire Tanks / Yard
Hydrants.Fire brigade body and NRV will be made of
gun metal.

Nos.

Sqm.

340

29

Excavation of earth and refilling with river sand 250 mm


above and below of pipe then with earth compaction Cu.m.
upto formed ground level.

750

30

Supply and installation of Orifice plate made out of


stainless steel 5mm thick 100 NB dia

Nos.

12

Nos.

Nos

10

kg

750

23

24

28

31

32

Description of Item

Supply & installation of 63mm dia. approved make GM


single headed fire hydrant landing valves (with
instantaneous female plunger type couplings, chained
blank caps) including making flanged joints by providing
necessary nuts, bolts, gaskets, etc. painting complete
as per specifications.
Supply & installation of RRL type-A hose cabinet of
63mm dia. x 15 meters long with heavy quality gun
metal male coupling of IS: 903. combined with 2 Nos of
Canvass hoses with painted MS hose tray and 1 No. of
nozzle.

Supply and wrapping of Coating & Wrapping Materials


manufactured as per IS 10221 (make:Pypkote) 4mm
thick for underground Pipes as per specification Steel
pipelines to be laid underground buried in the soil shall
be protected against corrosion by means of coating &
wrapping as per IS:10221.
The above coating and wrapping shall be carried out
in systematic manner such that uniform thickness of
coating is obtained as per IS specification.
Buried pipelines shall be laid in general with top of
pipe 1(one) meter below the ground level. Where
soil conditions are not satisfactory, masonry or
equivalent supports shall be provided at regular
intervals.The rate shall be inclusive of Holiday test for
underground pipes.

Construction of valve chambers with 345m thick brick


wall in CM 1:5,200mm thick PCC base of 1:4:8 and
internal size of 1m x 1m x1.3m depth with heavy duty CI
cover as per specification.Internal walls to be plastered
in CM 1:4.
Supply and erection of Hume pipes (NP3 class ) of
length 3 meters for the following diameters

300mm dia Hume Pipe

33

Supply and installaiton of Steel supports for piping like


clamps, tierods,brackets, nuts and bolts as per details
given in the drawings

III

SPRINKLER SYSTEM

Rate in
figures (in
Rs.)

Rate in words (in


Rs.)

Amount (in Rs.)

Item
No.

34

Description of Item

Unit

Quantity

Supply, erection, testing and installation of heavy class


black steel pipes conforming to IS 1239 with welded
joints including cutting the pipes to correct lengths,
fixing with clamps to MS brackets / hangers, steel
supports, hitec supports as per drawing. The hydro
testing shall be done at 18 kgs/cm 2 pressure. Rate shall
be inclusive of Zinc chromate primer over that 2 coats
red enamel panit as per Fire authorities requirement
over all above ground pies.Rates to inclusive of all
complete as per specifications (including heavy class
forged fittings of IS standards) of the following
diameters.
a 150 NB- Class C

Rmt

988

b 100 NB - Class C

Rmt

548

c 80NB - Class C

Rmt

544

d 65 NB - Class C

Rmt

767

e 50 NB - Class C

Rmt

1248

f 40 NB - Class C

Rmt

1988

g 32 NB - Class C

Rmt

24

h 25 NB - Class C

Rmt

6263

35

Supply and installation of Pendant type Sprinkler head


with the following temperature rating & respond,
universal
deflector,
chromium
finish
as
per
specifications. Size: 15-mm dia. The rate shall be Nos.
inclusive of Stainless steel Rossette plate in office area
and other false ceiling areas. Temperature Rating: 68C
Standard respond

1386

36

Supply, erection, testing and commissioning of


Temperature Rating: 68C standard response Upright Nos.
sprinklers for office area.

1412

Rate in
figures (in
Rs.)

Rate in words (in


Rs.)

Amount (in Rs.)

Item
No.

Description of Item

Unit

Quantity

37

Supplying & installing of approved make flow switches


(flow sensors) suitable to be fixed directly on line of the
following diameters, with 1 NO & 1 NC potential free
contacts

150 NB

38

Supply & installation of sprinkler annunciator panel


consisting of 50 windows, capable of working on 230
V AC single phase supply and provided with battery
Lot
back-up of 24 V complete as per specification. Each
windows shall be provided with potential free contact for
connecting to the BMS system

39

Supply & installation of Instrument cables for flow


switches to annunciator panel The cable should be 2
Rmt
core x 1.5 Sq.mm copper armoured cable. Complete as
per specification.

4500

40

Supply, installation, testing and commissioning of water


flow will activate a hydraulic powered water motor alarm
by way of integral valve alarm line trim piping. Water
motor gong shall be connected to a water pressure
retarding chamber to limit the propensity of unnecessary No.
alarms. Water motor alarm shall be equipped with a
rear closure plate to limit the access of foreign materials
of accumulation of debris.Size of alarm valve shall be
150NB.

41

Steel supports for piping like clamps, tierods,brackets,


nuts and bolts as per details given in the drawings.

Nos.

kg

16

750

Rate in
figures (in
Rs.)

Rate in words (in


Rs.)

Amount (in Rs.)

Item
No.

34

Description of Item

ABC Type Extinguisher

Nos.

96

Nos.

49

Nos

Nos.

5 Kg
Upright
13849

Carbon Dioxide Fire Extinguisher

Capacity Type
IS
-

Quantity

HYDRANT SYSTEM
PORTABLE FIRE EXTINGUISHERS:
Supply & installation of following Portable Fire
Extinguisher :

Capacity Type
IS
b

Unit

4.5 Kg
Upright
2878

Foam Fire Extinguisher

Capacity - 9 Litres
Type
- Upright, Trolley mounted
IS
- 10204

DCP Type Extinguisher

Capacity -

2 Kg

Type

Upright

IS

2171
Total C/o to Summary

Rate in
figures (in
Rs.)

Rate in words (in


Rs.)

Amount (in Rs.)

CONSTRUCTION OF AUDITORIUM AT NASC COMPLEX, PUSA, NEW DELHI

PART-II (Non-Scheduled Items based on Market rates (STP)


Item
No.

Description of Item

SEWAGE
TREATMENT
TECHNOLOGY)
SCHEDULE -1

PLANT

Supply, installation, testing, commissioning of Sewage


Treatment Plant (Excluding excavation, Back Filling &
Disposal of surplus)
Nature of Effluent - domestic Sewage from Toilet ,
Kitchen waste water shall be discharged in to the
STP,Design to take consideration of same.
Daily average flow Cum 60
PH - 7.5 to 8.5
BOD mg/ltr 450
Suspended Solids mg/ltr 200

Grit chamber
Screen Chamber
Oil & Grease Trap
Sewage equalization tank / sump
Aeration cum MBR Tank
Membranes
Chemical Cleaning Tank
Sludge Holding Tank
Air Blowers, Pumps & equipment
Piping, valves etc
Electrical Panel & Cabling
Supply of Coarse Bar Screen
Supply, installation, testing & commissioning of 1 Nos
fine Screen to remove the particle size above 3 mm with
suitable arrangement.
Supply, installation, testing & commissioning of electronic
type level indicator and controller for automatic operation
of the system with high/low level alarm complete with
auxiliary NO / NC contacts for each tank.
Supply, installation, testing & commissioning of non
clogging type pumps capable of handling solids up to
35mm having CI casing & SS impeller & Shaft complete
with all accessories, motor of required capacity. Delivery
header with isolation valve, pressure gauge on delivery
line with isolation cock, level controller (with wiring) to
control the level of sump automatically. Pumps shall
have following duty:
Submersible Sewage Pumps for transfer of Raw Sewage
from EQT to Aeration Tank (1 working & 1 standby):Sludge disposal pump - (2 Nos - 1 working + 1 Standby)
Air diffusion system shall include the following:Twin type rotary air blowers capable of delivering
required amount of free air at required pressure driven
through V belt or directly coupled through flexible
coupling to a TEFC motor of suitable HP Suitable for 415
10% volts, 3 phase, 50 cycles A/C supply.
The air blowers shall be of for the following purposes of
suitable capacity :
a) For Equalization and Aeration Tank (1 Working + 1
Standby)
b) For MBR Tank (1 Working + 1 Standby)

Quantity

Job

(MEMBRANE

COD mg/ltr 800


Oil & Grease mg/ltr 50
Effluent discharge standard after treatment
pH - 6.5 to 7.5
BOD mg/ltr < 5
Suspended Solids mg/ltr Nil
COD mg/ltr < 10
Oil & grease mg/ltr BDL
Turbidity NTU < 4
E coli Removal - Removal to the level of log 6
Sewage treatment plant shall include the following items:

Unit

Air piping shall comprise of pipes droppers / laterals with


MS (epoxy coated) Header complete with all fittings such
as
tees,
crosses,
plugs,
sockets,
elbows,
reducers,supports & clamps, puddle flanges etc cutting
chases & making good.

Rate in
figures (in
Rs.)

Rate in words (in Rs.)

Amount (in Rs.)

10

11

12

13
14

Non clog type air dispersion system capable of handling


3- 5 cfm of air with oxygen transfer efficiency of 3-4% per
/ meter water depth. Air dispersion grid shall be
assembled in modular form so that they can be replaced
/ repaired easily from plat form at the top. (Imported fine
bubble membrane diffusers).
Bronze Ball valve and air dispersion grid as required for
STP
Note: Air dispersion system shall be provided for
Collection Sump, aeration tanks and Sludge Holding
Tank.
Providing and fixing all piping and isolation control valves
for making the system complete SS 304: Submerged air
piping GI (HEAVY): Air piping & pumped effluent riser
(nonsubmerged
Supply, installation, testing & commissioning of Chemical
Cleaning system comprising suitable capacity of
Chemical Cleaning tank filled with Sodium Hypochlorite
and Citric Acid solution in required proportion and
centrifugal pump. The centrifugal pump shall be non clog
water pumps with CI Head & Base. (1 Working + 1
Standby)
Supply, installation, testing and commissioning of
membrane modules suitable for 60 KLD consisting of flat
sheet / hollow fiber membranes housed in SS 304 /
PVDF housing with SS 304 permeate water manifold and
aeration diffuser system complete as required.
Supplying, installing, testing & commissioning of
horizontal centrifugal non clog water pumps with CI Head
& Base, SS Impeller of suitable capacities along with
motor, pressure gauge with isolation cock, Isolation
valve, NRV on delivery line. Isolation valve, strainer (with
by-pass) at suction. Mechanical seal, suitable vibration
elimination pads of approved design, drain pipe with
valve (25 dia) for the pump. The pump shall be suitable
for 41510% volts 3 phase AC supply (1 Working + 1
Standby)
Membrane suction pump with VFD Nos. Membrane Feed
Pumps
Supply, installation, testing & commissioning of the PLC
based control panel with interlocking arrangement with
supply pumps, suction pumps, chemical cleaning tank,
modulating or shut-off valves including necessary wiring,
magnetic switches & sensors complete to make the
system functional with following interlocking

a
b

Suction pump stop-Supply pump stop


Suction pump's head loss greater then set suction headSuction pump stop & Chemical cleaning pump start

Suction pump's head loss greater then set suction headSuction pump's suction header valve stop

Suction pump's head loss greater then set suction headChemical pumps delivery valve open in suction pump's
suction header

15

Providing Of Prefabricated Skid Comprising of Bioreactor


Tank , MBR Tank . LOT
SCHEDULE-2
STP ELECTRICAL WORKS
NOTES:-Contractor shall note that the quantities given
under this schedule are "Provisional' and are subject to
remeasurement upon completion for payment purpose.

B
1

Supply, Installation / Laying, Testing & Commissioning of


the following:
ELECTRICAL EQUIPMENTS
PANEL
Design,
fabrication,
assembling,
wiring,
supply,installation, testing and commissioning of motor
control centre shall be fabricated out of 14 gauge CRCA
sheet steel in form in 3b formation with reinforcement of
suitable size angle iron, channel T sections irons and/or
flats wherever necessary. Cable gland plates shall be
provided on top as well as at the bottom of the panels.

Panels shall be treated with all anticorrosive process


before painting as per specifications with 2 coats of red
oxide primer and final approved shade of powder coated
paint. 2 No. earthing terminals shall be provided for 3
phase, 4 wire, 50 Hz supply system. Lifting hooks shall
also be provided in case of large panels. Approval shall
be taken for each panel before fabrication. Cadmium
Plated hardware shall be used in fabrication of panels.

Quoted rates shall inclusive of cables, cable trays (in


accordance to specification) with earthing from panel to
each motor / equipment.

Incoming 1
400 amps (25kA) TPN MCCB with the following
accessories: 1
0-500 volts 96 x 96 mm square electronic voltmeter with
selector switch shall be protected by 2 amps TP MCB. 1
Set 1
0-400amps 96 x 96 mm square electronic ammeter with
selector switch and 400./5 amps 10 VA CL:1 CTs. 1 Set
1
Phase indicating lamps shall be protected by 2 amp SP
MCB 3 Set 1 Bus Bar 1 600 amps TPN (25 KA)
aluminium bus bar with heat shrinkable insulation
sleeves. 1
2 No. suitable rating MCB for 1.5 HP DOL starter and
outgoing feeder to EQT effluent transfer pumps motor
(including 1nos. standby). Each compartment shall
contain auto / manual selector swtich and indicating /
pushbutton lamps with MCB for ON / OFF / TRIP of
motor. 1
2 No. suitable rating MCB for 3 HP direct on line starter
and outgoing feeder to air blowers for Equalisation and
Aeration Tank (including 1 no. standby). Each
compartment shall contain auto/manual selector switch
and indicating lamps with MCBs for ON/OFF/TRIP'
status of motor 1
2 No. suitable rating 4P MCB for 3 HP Star delta starter
and outgoing feeder to air blowers for MBR Tank
(including standby). Each compartment shall contain
auto/manual selector switch and indicating lamps with
MCBs for ON/OFF/TRIP' status of motor 1
2 No. suitable rating 4P MCB for 1 HP DOL starter and
outgoing feeder to Sludge removal pumps motor
(including 1No. standby). Each compartment shall
contain auto / manual selector swtich and indicating /
pushbutton lamps with MCB for ON / OFF / TRIP of
motor. 1
2 No. suitable rating 4P MCB for 1.0 HP direct on line
starter and outgoing feeder to Membrane Suction Pump
(including standby). Each compartment shall contain
auto/manual selector switch and indicating lamps with
MCBs for ON/OFF/TRIP' status of motor 1

2 No. suitable rating 4P MCB for 0.37 KW direct on line


starter and outgoing feeders to Chemical Cleaning
Pump. Compartment shall contain auto / manual selector
switch and indicating lamps with MCBs for
ON/OFF/TRIP status of motor. 1

10

2 Nos 4P MCB for 1.5HP direct on line starter and out


going feeders to Sump Pump(including 1 no. standby).
Each compartment shall contain direct operated (0-40) A
ammeter with auto/manual selector switch and indicating
lamp with MCBs for ON/OFF/TRIP status of
motor.status of motor.
1 No. 16 amps TPN MCCB outgoing feeder to Automatic
Step type bar screen. 1
1 No. 16 amps TPN MCCB outgoing feeder to Automatic
Drum type fine screen. 1
1 No. 16 amps TPN MCCB outgoing feeder to Automatic
Screw type Centrifuge. 1
Necessary
cable alleys, internal wiring, and
interlocking,earthing for all equipment shall also included
1 Spare of following capacities: 1

11
12
13
14

i. 32 amps 4 Pole MCB 2 Nos. 1


ii. 63 amps TPN MCCB 1 Nos. 1
Notes:
a. All MCCBs shall be of 25 KA breaking capacity
b. All motor starter shall be provided with Automatic level
c. Provision shall be made for providing potential free
MCC-1 for STP as described above

CONSTRUCTION OF AUDITORIUM AT NASC COMPLEX, PUSA, NEW DELHI


MAIN ELECTRICAL WORKS
SUMMARY SHEET
S.No.

Description

Lifts and Escalator

Electrical Works

DG System

Solar System

HVAC WORKS

IBMS Works

TOTAL AMOUNT

DSR Amount ( in Rs.)

435,851.00
37,032.00

NSRAMOUNT(inRs.)

ELECTRICAL WORK
ITEM
SR REF.
No.
NO.
SOR Items

Qty

Unit

Rate in
Rupees

Total Amount
in Rupees

Each

4820

38560

3.5 Core X 400 Sq.mm XLPE


Aluminium armoured Cable

26

Each

508

13208

3.5 Core X 300 Sq.mm XLPE


Aluminium armoured Cable

Each

508

2032

3.5 Core X 240 Sq.mm XLPE


Aluminium armoured Cable

Each

381

762

DSR Rate.
Refer Part-13.5 Core X 185 Sq.mm XLPE
External,
Aluminium armoured Cable
Page-77,
Code:4.1.27

Each

319

638

DSR Rate.
Refer Part-13.5 Core X 150 Sq.mm XLPE
External,
Aluminium armoured Cable
Page-76,
Code:4.1.26

Each

278

1668

DSR Rate.
Refer Part-13.5 Core X 120 Sq.mm XLPE
External,
Aluminium armoured Cable
Page-75,
Code:4.1.25

Each

199

796

Description of Item

Design, supply, termination,


testing and commissioning of
SOR
Rate.
INDOOR type termination
Refer
Partkit and accessories suitable
1
153-External,
for 11KV, 3 core 240 Sqmm
Code:5.1.3
XLPE cable. ( 1set = RYB
phase)
Supply & making end
termaination
with
brass
compression
gland
and
SOR Rate 4.1 aluminium lugs for following
2 MVET
size of PVC insulated and
External
PVC sheathed / XLPE Al
conductor cable of 1.1 KV
grade as required.

DSR Rate.
Refer Part-1External,
Page-81,
Code:4.1.31
DSR Rate.
Refer Part-1External,
Page-80,
DSR Rate.
Refer Part-1External,
Page-79,
Code:4.1.29

ITEM
SR REF.
No.
NO.
SOR Items

Description of Item

Qty

Unit

Rate in
Rupees

Total Amount
in Rupees

3.5 Core X 95 Sq.mm XLPE


Aluminium armoured Cable

Each

197

788

3.5 Core X 70 Sq.mm XLPE


Aluminium armoured Cable

Each

168

336

3.5 Core X 50 Sq.mm XLPE


Aluminium armoured Cable

Each

146

292

DSR Rate.
Refer Part-13.5 Core X 35 Sq.mm XLPE
External,
Aluminium armoured Cable
Page-71,
Code:4.1.21

Each

137

822

4 Core X 25 Sq.mm XLPE


Aluminium armoured Cable

110

Each

137

15070

4 Core X 16 Sq.mm XLPE


Aluminium armoured Cable

90

Each

196

17640

Earthing with copper earth


plate 600mmx600mmx3mm
thick including accessories
and providing masonary
enclosure with cover plate
having locking arrangement
and watering pipe etc. (but
without charcoal or coke and
salt) as required

Each

3263

6526

Each

1484

2968

DSR Rate.
Refer Part-1External,
Page-74,
Code:4.1.24
DSR Rate.
Refer Part-1External,
Page-73,
Code:4.1.23
DSR Rate.
Refer Part-1External,
Page-72,
Code:4.1.22

DSR Rate.
Refer Part-1k
External,
Page-84,
Code:4.1.34
DSR Rate.
Refer Part-13 External,
Page-83,
Code:4.1.33

SOR No.
4 3.6
EARCUPL

Salt / coke for plte earth

SOR No.
electrode, extra for using salt
and coke for GI or copper
5 3.8
EARCOKPL plate earth electrode as
required.

ITEM
SR REF.
No.
NO.
SOR Items

Qty

Unit

Rate in
Rupees

Total Amount
in Rupees

GI earth pipe Electrode with


salt / charcoal earthing with
GI earth pipe 4.5 meter long,
40mm
dia
including
SOR No.
accessories
and
providing
3.2
6
masonaries enclosure with
EARPIPCHA
cover plate having locking
R
arrangement and watering
pipe etc. with charcoal and
salt as required.

10

Each

1971

19710

Supply and laying of 8 gauge


bare copper wire for Gland
SOR Rate.
earthing, loop earthing in the
Refer Part-1existing
surface/recessed
7
internal, Pagesteel conduit, DB earthing
315, Code:3.9
and other equipment body
earthing as required.

500

R.M

41

20500

Providing and fixing HT


danger notice plate of
250mmx200mm made of
mild stell atleast 2mm thick
and vitreous enamelled white
on both side and with
inscrisption in single red
color on front size as
required

10

Each

75

750

Providing and fixing MV


danger notice plate of
200mmx150mm made of
mild stell atleast 2mm thick
SOR No. 2.71
9
and vitreous enamelled white
DANPLMV
on both side and with
inscrisption in single red
color on front size as
required

10

Each

68

680

35

Each

61

2135

SOR NO.
2.72
DANPLHV

Description of Item

Supply & fixing following


modular switch / socket on
SOR No. 1.24
existing modular plate &
10 MODSWEB
switch
box
including
Internal
connection but excluding
modular plate.

1.24.6

Telephone socket outlet

ITEM
SR REF.
No.
NO.
SOR Items

Description of Item

Qty

Unit

Rate in
Rupees

Supply & fixing following size


/ modules GI box along with
SOR No. 1.27
modular base and cover
11
MODGIBXCP
plate for modular switches in
recess etc as required.

1.27.1

1 or 2 module (75mmx75mm)

Total Amount
in Rupees

35

Each

88

3080

Supply & fixing of following


size of steel conduit along
with accessories in surface /
SOR No. 1.20 recess including painting in
12
case of surface conduit or
STLCON
cutting the wall and making
good the same in case of
recess conduit as required.
a

1.20.1

20mm

200

R.M

77

15400

1.20.2

25mm

250

R.M

86

21500

1.20.4

40mm

100

R.M

127

12700

1.20.5

50mm

100

R.M

168

16800

Supply & fixing of following


size of PVC conduit along
with accessories in surface /
SOR No. 1.21 recess including painting in
13
case of surface conduit or
PVCCON
cutting the wall and making
good the same in case of
recess conduit as required.
a

1.21.1

20mm

800

R.M

41

32800

1.21.2

25mm

3000

R.M

47

141000

1.21.4

40mm

200

R.M

67

13400

1.21.5

50mm

100

R.M

90

9000

ITEM
SR REF.
No.
NO.
SOR Items

Qty

Unit

Rate in
Rupees

Total Amount
in Rupees

Supply, fixing suitable size


GI box with modular plate
and cover in front on surface
or in recess
including
providing
and
fixing
3 pin 5/6
SOR No. 1.31
14
Amp
modular
socket
outlet
LPACCMOD
and 5/6 Amp modular switch
connection, painting etc as
required for UPS / Raw
Power Socket.

105

Each

160

16800

Supply, fixing suitable size


GI box with modular plate
and cover in front on surface
or in recess
including
providing and fixing 6 pin
SOR No. 1.32
15/16 Amp and 5/6 amp
15
PPACCMOD
modular socket outletand
15/16 Amp modular switch
connection, painting etc as
required for UPS / Raw
Power Socket.

35

Each

214

7490

Description of Item

TOTAL
SOR
AMOUNT

External

435851

DG WORKS

SOR No.
1 3.6
EARCUPL

Earthing with copper earth


plate 600mmx600mmx3mm
thick including accessories
and providing masonary
enclosure with cover plate
having locking arrangement
and watering pipe etc. (but
without charcoal or coke and
salt) as required

Each

3263

13052

Each

1484

5936

Salt / coke for plte earth

SOR No.
electrode, extra for using salt
2 3.8
and coke for GI or copper
EARCOKPL plate earth electrode as
required.

ITEM
SR REF.
No.
NO.
SOR Items

Description of Item

GI earth pipe Electrode with


salt / charcoal earthing with
GI earth pipe 4.5 meter long,
SOR No.
40mm
dia
including
3.2
accessories and providing
3
EARPIPCHA masonaries enclosure with
cover plate having locking
R
arrangement and watering
pipe etc. with charcoal and
salt as required.

Qty

Unit

Rate in
Rupees

Total Amount
in Rupees

Each

1971

7884

20

Each

508

10160

Supply and termination of the


following size cables with
SOR No. 4.1
4.00
suitable double compression
MVET
glands with suitable crimping
socket.
a

3.5 Core X 400 Sq.mm PVC


Aluminium armoured Cable
DSR
Amount
WORKS (Rs.)

of

DG

37032

CONSTRUCTION OF AUDITORIUM AT NASC COMPLEX, PUSA, NEW DELHI


PASSENGER LIFTS, SERVICE LIFTS AND ESCALATORS
(DESIGN, MANUFACTURE, SUPPLY, ERECTION, TESTING, COMMISSIONING INCLUDING MAINTENANCE)
PRICED BILLS OF QUANTITIES
Annexure A (LIFTS & Escalator)
S.No.

Description

Qty

Unit

Rate
In Figure

PASSANGER LIFT ( VVIP 1 AND 2 WITH LIFT NO 2,3,4


AND 5 )
REFER DWG NO : DWG:NASC-AUD-AR07-01-01141343 ,DWG:NASC-AUD-AR07-01-01-141345
Supplying, installation, testing & commissioning of 1360
kGS (20 Nos) capacity lift of machine room type
elevator standard design conforming to latest lift act and
modern lift with microprocesor including AC gearlessVVVF controller in the existing lift well / shaft having
minimum speed of 1 M/swith a total travel of 16.00
(Appox.) mtrs. Basement, Ground Floor, First Floor and
Second floor 4 stops and 4 landings. on same side. The
lift shall be complete with SS Canvass Finish bright
annealed finish stainless steel for car, car doors, landing
doors etc., (with all car interiors complete as per
specification)

Nos.

Nos

The lift shall be of excellent quality and shall have Micro


stroke push buttons, intelligent group controls of eight lifts,
floor announcement system, Gearless and other features
as per detailed specifications attached. The lift car shall
have two parallel car operating control panels in automatic
mode (with or without attendant) and from one panel in
attendant mode.
The lift equipment will be installed in the machine room
directly above the lift well. All the lift equipments, i/c car,
car doors self-levelling devices, control devices,
indicators, landing doors, indicators, buffer ropes safety
devices i/c all wiring connection, interconnection and all
connected equipments shall be as per specifications. The
work also includes all structural items in machine room
and above the lift well like RCC block, & MS girders
required for lift insallations & providing miscellaneous
items like supports for guide rails, overhead gears,
scaffoldings, sill projections, facia inside the lift well, minor
building works like making sockets, holes etc. i/c making
good the damages.
II

PASSENGER LIFT ( LIFT NO :1)


DWG:NASC-AUD-AR07-02-01-141344
Supplying, installation, testing & commissioning of
1360kGS (20 Nos) capacity lift of machine room type
elevator standard design conforming to latest lift act and
modern lift with microprocesor including AC gearlessVVVF controller in the existing lift well / shaft having
minimum speed of 1.0m/sec with a total travel of 11.65
(Appox.) mtrs. First Floor To Second floor 2 stops and 2
landings. on same side. The lift shall be complete with SS
Canvass Finish bright annealed finish stainless steel for
car, car doors, landing doors etc., (with all car interiors
complete as per specification)
The lift shall be of excellent quality and shall have Micro
stroke push buttons, intelligent group controls of eight lifts,
floor announcement system, Gearless and other features
as per detailed specifications attached. The lift car shall
have two parallel car operating control panels in automatic
mode (with or without attendant) and from one panel in
attendant mode.
The lift equipment will be installed in the machine room
directly above the lift well. All the lift equipments, i/c car,
car doors self-levelling devices, control devices,
indicators, landing doors, indicators, buffer ropes safety
devices i/c all wiring connection, interconnection and all
connected equipments shall be as per specifications. The
work also includes all structural items in machine room
and above the lift well like RCC block, & MS girders
required for lift insallations & providing miscellaneous
items like supports for guide rails, overhead gears,
scaffoldings, sill projections, facia inside the lift well, minor
building works like making sockets, holes etc. i/c making
good the damages.

Amount in Rs.
In words

S.No.

Description

Qty

Unit

Rate
In Figure

The lift equipment will be installed in the machine room


directly above the lift well. All the lift equipments, i/c car,
car doors self-levelling devices, control devices,
indicators, landing doors, indicators, buffer ropes safety
devices i/c all wiring connection, interconnection and all
connected equipments shall be as per specifications. The
work also includes all structural items in machine room
and above the lift well like RCC block, & MS girders
required for lift insallations & providing miscellaneous
items like supports for guide rails, overhead gears,
scaffoldings, sill projections, facia inside the lift well, minor
building works like making sockets, holes etc. i/c making
good the damages.
III

SERVICE LIFT ( LIFT NO 1)


DWG:NASC-AUD-AR07-02-01-141344
Supplying, installation, testing & commissioning of 1360
kGS (22 Nos) capacity lift of machine room type
elevator design conforming to latest lift act and modern
lift with microprocesor including AC-VVVF controller in the
existing lift well / shaft having minimum speed of 0.5m/sec
with a total travel of 16.00 mtrs. Basement, Ground, First
and Second floor, servicing 4 stops and 4 landings on
same side. The lift shall be complete with factory
enamelled / paint finish for car enclosure, ceiling & car
doors and landing doors shall be 16 G Vandal proof
stainless steel door and handle inside the car. (with all car
interiors complete as per specification)

Nos

Nos

The lift shall be of excellent quality and shall have Micro


stroke push buttons, intelligent group of simplex controls,
floor announcement system, Gearless machine and other
features as per detailed specifications attached. The lift
car shall have car operating control panel (1no) in
automatic mode (with or without attendant) and from one
panel in attendant mode.
The lift equipment will be installed in the machine room
directly above the lift well. All the lift equipments, i/c car,
car doors self-levelling devices, control devices,
indicators, landing doors, indicators, buffer ropes safety
devices i/c all wiring connection, interconnection and all
connected equipments shall be as per specifications. The
work also includes all structural items in machine room
and above the lift well like RCC block, & MS girders
required for lift insallations & providing miscellaneous
items like supports for guide rails, overhead gears,
scaffoldings, sill projections, facia inside the lift well, minor
building works like making sockets, holes etc. i/c making
good the damages.
IV

ESCALATORS ( 2 NOS )
DWG:NASC-AUD-AR07-02-01-141344
Supply ,installation,testing and commissioning of
Escalator with Machine of capacity not less than 9000
persons per hour and at a speed of a 0.5m/sec with an
inclination of 35 Degree including all necessary ancillaries
and accessories as specified in the Tender Document
and specification .It shall comply with all statutory
requirement of the local Competent Authorities.
The above rates shall include approval / obtaining
completion certificate from the electrical / lift inspectorate
of Local Competent Electrical Authority / Lift Liecense for
installation and commissioning of lifts before handing over
the entire installation of the lift.
Note: Vendors should give options for car Interiors. The
final specificfation shall be as per ICAR requirement.
TOTAL LIFT & ESCLATOR AMOUNT

EXTERNALELECTRICALWORKS
SECTION - A :- Equipments - HT Panel Board,
Transformers, HT cable & Busduct.

Amount in Rs.
In words

S.No.

Description

Qty

Unit

Rate
In Figure

For all items in section-A, the rate includes necessary


connected minor civil works if required and necessary
supports as required at site. No extra payment will be
made for the same.
Note: Foundation for RMG, HT Outdoor Panel,
Transformer, DG sets & Fuel tank etc will be in the
scope of civil contractor
Design,supply,Installation,Testing and Commissioning of
OUTDOOR Weather & Dust proof Type, floor mounting,
free standing 11kV Ring Main Gear unit made out of M.S
sheet steel clad dust and vermin proof with 630A Copper
Busbars,
Interconnections,
necessary
protections,
Measuring Instruments, Indicating Instruments, Protection
Relays, CTs, PT with necessary control fuses/MCBs,
16 Termination arrangements for Incoming and Outgoing
Cable of 11 kV 3Core 240 Sq mm XLPE Alu.Armoured
earthed cable, Terminal Blocks, Earthing,Powder coated
painting, Sign writing and Base channels etc., with
complete all accessories as required for satisfactory
operations and as
per the detailed Technical
Specifications enclosed and as per EB Requirements
comprising of the following
INCOMER (2 Sources) :
11kV, 630A, 500MVA LOAD Break Switch (Air Break )
with necessary required accessories - 2Nos
OUTGOING :
11kV, 630A, 500MVA VACCUM Circuit Breaker with
necessary required accessories : 1No
The RMG panel shall be manufactured as required by the
electrical authorities and approval shall be obtained
including testing & commissioning and any additional
features required by the supply authorities shall be carried
out at no extra cost
Supplying and spreading of 150mm sand cushion base,
supplying and providing 300mm 40mm blue metal jelly
17 and other associated works., earthing arrangement for
fencing and gate complete as required by the CEA / CEIG
regulation.
Design, supply, installation, testing and commissioning of
11KV 630A, 500MVA, 26.2KA, Drawout type VCB
Breaker HT Outdoor single Panel Board with all
18 accessories and all metering protection for satisfactory
operation and as required by the statutory electrical
authorities as per the detailed specification enclosed.
Supplying and spreading of 150mm sand cushion base,
supplying and providing 300mm 40mm blue metal jelly
19 and other associated works., earthing arrangement for
fencing and gate complete as required by the CEA / CEIG
regulation.

Design, supply, installation, testing and commissioning of


11KV 630A, 500MVA, 26.2KA, Drawout type VCB
Breaker HT indoor single Panel Board with all
20 accessories and all metering protection for satisfactory
operation and as required by the statutory electrical
authorities as per the detailed specification enclosed.

Design, supply, installation, testing and commissioning of


1250KVA, 11 kV/433V outdoor, Dry type cast resin
Transformer with ON load tap changer as per the
detailed specification enclosed. Transformer Protection
relays should be provided at Transformer such as
Transformer Buchholz relay, restricted earth fault
21 relay,winding temp relay, Auxiliary relays as per
standards. The transformer shall be provided with cable
termination box on HT side to terminate 3 core 240 Sqmm
XLPE cable and suitable for terminating air insulated
copper busduct on LT side 4000A Amps rating all as per
the detailed specification enclosed.

Each

LS

Each

LS

Each

Each

Amount in Rs.
In words

S.No.

Description

Qty

Unit

Rate
In Figure

Supplying and spreading of 150mm sand cushion base,


supplying and providing 300mm 40mm blue metal jelly
and other associated works., earthing arrangement for
22 fencing and gate complete as required by the CEA / CEIG
regulation.

Design, supply, laying, testing and commissioning of 3


core 240 sqmm (E) 11KV, HT XLPE Aluminium
conductor individual core screened, flat steel strip
armoured, PVC sheathed cable inside the building in
23 trench with exacavation and proper filling, sand cushioning
and brick protection as per specification(From 11KV RMG
to 11KV outdoor HT single panel, 11KV indoor HT panel,
Transformer)

LS

300

R.M

10

R.M

R.M

Each

Each

Each

Design, supply, erection, testing and commissioning of


2000 Amps INDOOR TYPE 4 Pole Sandwich Copper
busduct with flexible joints at every 4.5Mtr. Interval
(RYBN) with suitable support as per the detailed
24 specification enclosed. The busduct should be with
straight run, 90 deg. Horizontal and vertical bends., busbar
trunking fittings (elbow, tees, end End (Cable) feed Box,
end covers, horizontal fixing devices,etc.)
The busduct shall run from Transformer secondary to
MPCC Panel. Horizontal runs of busbar trunking system
shall be supported by hangers at every 2 metre. Vertical
runs of busbar trunking system shall be supported by
hangers not more than 4m apart.
Busbar trunking system shall be terminated by end
caps(closure). The bus duct shall be fabricated as per the
detailed specification enclosed. Current Density of
busbars shall not exceed 1.2 Amps/ Sq.mm.The rate shall
be inclusive of steel support with painting and all other
necessary accessories

Design, supply, erection, testing and commissioning of


1250 Amps INDOOR TYPE 4 Pole Sandwich Copper
busduct with flexible joints at every 4.5Mtr. Interval
(RYBN) with suitable support as per the detailed
25 specification enclosed. The busduct should be with
straight run, 90 deg. Horizontal and vertical bends., busbar
trunking fittings (elbow, tees, end End (Cable) feed Box,
end covers, horizontal fixing devices,etc.)
The busduct shall run from MPCC Panel to APFCR panel.
Horizontal runs of busbar trunking system shall be
supported by hangers at every 2 metre. Vertical runs of
busbar trunking system shall be supported by hangers not
more than 4m apart.
Busbar trunking system shall be terminated by end
caps(closure). The bus duct shall be fabricated as per the
detailed specification enclosed. Current Density of
busbars shall not exceed 1.2 Amps/ Sq.mm.The rate shall
be inclusive of steel support with painting and all other
necessary accessories

Design, supply, erection, testing and commissioning of

26 2000 Amps Phase cross changeover box suitable for


sandwich copper bus duct including all accessories.

27

Design, supply, erection, testing and commissioning of


1250 Amps Phase cross changeover box suitable for
sandwich copper bus duct including all accessories.

Design, supply, erection, testing and commissioning of


Battery Charger 110V DC 100 AH Trip unit combined
with trickle & boost charge facilities with battery bank
28 (SMF) & Distribuition Board and as per the detailed
specification/drawing enclosed.

Amount in Rs.
In words

S.No.

Description

Qty

Unit

Rate
In Figure

Providing, 9" Brick wall below FFL 500mm and above FFL
300mm with double side plastring and 2.1 mtr height
weldmesh fencing with vertical angle iron supports( with
RCC) spaced as per standards, hinged lockable door for
each yard as required, painting with red oxide and
aluminium paint as required, suitable necessary civil
29
foundation, necessary anlge iron support and earthing
arrangment complete as required by the CEA / CEIG
regulation for RMG, HT outdoor panel, DG Yard etc. The
rate shall inclusive of providing necessary gates with
suitable tubular supports.

Soil Excavation of site 600mm x 600mm x 1500mm (


Maximum ) for construction of inspection pit, construction
of brick masonary pit of side 600mm x 600mm x 375mm
30 including plastering and providing RCC Frame with RCC
Precast slab provided with Edge beading

Soil Excavation of site 1200mm x 600mm x 1500mm (


Maximum ) for construction of inspection pit, construction
of brick masonary pit of side 600mm x 600mm x 375mm
31 including plastering and providing RCC Frame with RCC
Precast slab provided with Edge beading

100

Sq.Mtr

20

Each

Each

100

R.M

100

R.M

100

R.M

Supply and laying of the following size RCC hume pipes


with collar including excavation to a depth of 750mm to
32 1000mm from existing ground level, back filling, ramping
the soil, making the surface to match the original surface
as required.
100 mm dia (Class "NP2")

a
200 mm dia (Class "NP2")

b
300 mm dia (Class "NP3")

Section-B: MPCC & Sub LT Panels


For all items in section-B, the rate includes necessary
connected minor civil works if required and necessary
supports as required at site. No extra payment will be
made for the same.
Design, supply, erection, testing and commissioning of
cubicle type floor mounting main power control centre
33 made out of MS sheet enclosure with Copper busbars,
single busbar system, cable chamber, interconnection,
painting, earthing, protection relays etc. comprising of the
following : (MPCC)
INCOMING
EB Incomer
1 No. 2000 Amps 4 Pole 65KA electrical draw out type
Air circuit breaker with shunt release shutter assembly,
door interlock and all other accessories.
Instruments Panel
Digital type Ammeter with selector switch, Voltmeter with
selctor
switch,
Maximum
demand
controller,
Instantaneous earthfault relay (2 O/C+ 1 E/F), Low set
earth fault relay (51G), CTs control fuses, RYB Indication
lamps and ON/OFF/Trip" indicating lamp in each
incomer, and also refer the drawing.
DG Incomer
1 No. 2000 Amps 4 Pole 65KA electrical draw out type
Air circuit breaker with shunt release shutter assembly,
door interlock and all other accessories.
Instruments Panel
Digital type Ammeter with selector switch, Voltmeter with
selctor switch, CTs control fuses, RYB Indication lamps
and ON/OFF/Trip" indicating lamp in each incomer, and
also refer the drawing.
Buscoupler

Amount in Rs.
In words

S.No.

Description

Qty

Unit

Rate
In Figure

1No.2000 Amps 4 pole 65KA electrical draw out type Air


circuit breaker with shunt release, shutter assembly, door
interlock and all other required necessary accessories and
ON/OFF lamps.
The buscoupler shall be provided with mechanical &
electrical Inetrlocking arrangements.
OUTGOINGS
1250A 4P EDO ACB, 50 KA 1No
800A 4P EO MCCB, 50 KA 3Nos
630A 4P EO MCCB, 50 KA 2Nos
400A 4P EO MCCB, 50 KA 10Nos
All the Outgoing feeder should be ON/OFF/Trip indication
lamps, Digital type Multifuction meter(Except capacitor
feeder which is provided with Ammeter), CTs,Fuse, Switch
control,Front operting handles etc. All switch boards shall
be fabricated as per the detailed specification enclosed.
Suitable size outgoing cable chamber and extra busbars
should be provided for connecting the number of outgoing
cables as per the schematic drawing. The board shall be
fabricated for future extension of the panel board.
The transformers incomer shall be provided with
protection relays such as IDMT (2 O/C +1 E/F), Maximum
demand controller, REFR (Restricted Earth fault
Relay),etc., and bus coupler shall be both mechanical and
electrical interlocking arrangements by hardware control
wiring alongwith PLC (Programmable Logic Controls). The
Hardware control wiring & PLC operation shall be feasible
to extend for future Transformer if any and all as per the
detailed specification and drawings enclosed. This incoming and outgoing breakers shall be
Microprocessor based release such as overload,short
circuit,earth fault,neutral protection,etc.
Main Power Control Centre (MPCC)
2000Amps TPN Copper busbars:- All the neutral
busbars shall have half the capacity of phase
busbars.(1.2A/Sq. mm.)

34

Each

Each

Design, supply, fixing, testing and commissioning of


cubicle type floor mounting switch board comprising of the
following, the board shall be fabricated as per the detailed
specification enclosed. (APFCR Panel)
Incoming
1250A TP&N MDO ACB 65 KA Drawout type with Auto
power factor correction relay with necessary CT, control
wiring etc.- 1 No. as incomer.
Outgoing: Total 425 KVAR
2 sets of 100 KVAR (4 x 25 KVAR) with 400A TP MCCB,
suitable contactors with switching steps in the rating of
100 KVAR as required.
3 sets of 50 KVAR (2 x 25 KVAR) with 200A TP MCCB,
suitable contactors with switching steps in the rating of 50
KVAR as required.
3 sets of 25 KVAR (1 x 25 KVAR) with 100A TP MCCB,
suitable contactors with switching steps in the rating of 25
KVAR as required.
Each All KVAR capacitor bank in a separate compartment
with necessary ventilation arrangemnts or weld mesh
arrangements as required by the Electrical Authorities .
With necessary copper busbars, interconnections,
providing Ammeter with selector switches, phase
indication lamp, control fuse and switch control, PF meter
etc. as per the specification.
Capacitor Panel - 425 kVAR
1250 Amps TPN Copper busbars:- All the neutral
busbars shall have half the capacity of phase busbars
(1.2A/Sq. mm)

Design, supply, fixing, testing and commissioning of


cubicle type floor mounting switch board comprising of the
35 following, the board shall be fabricated as per the detailed
specification enclosed. (HVAC & Ventilation Panel)

INCOMING
630A TPN MCCB 35 KA with connected accessories
1No.as incomer

Amount in Rs.
In words

S.No.

Description

Qty

Unit

Rate
In Figure

OUTGOINGS
200A TPN MCCB, 16 KA 3Nos
100A TPN MCCB, 16 KA 5Nos
With necessary copper busbars, interconnections,
providing Digital type voltmeter, ammeter with selector
switches, ON,OFF,TRIP, phase indication lamp, Fuse,
Switch control etc.and also refer the drawing.
The incoming and outgoing breakers shall be
Microprocessor based release such as overload,short
circuit,earth fault,neutral protection,etc.
HVAC & VENTILATION PANEL
630A Amps TPN copper busbars : All the neutral
busbars shall have half the capacity of phase busbars
(1.2A/Sq. mm.).

36

37

38

Design, supply, fixing, testing and commissioning of


cubicle type floor mounting switch board comprising of the
following, the board shall be fabricated as per the detailed
specification enclosed. (AHU Panel-1,2,3)
INCOMING
100A TPN MCCB 25 KA with connected accessories
1No.as incomer
OUTGOINGS
32A TPN MCCB, 16 KA 8Nos
With necessary copper busbars, interconnections,
providing Digital type voltmeter, ammeter with selector
switches, ON,OFF,TRIP, phase indication lamp, Fuse,
Switch control etc.and also refer the drawing.
The incoming and outgoing breakers shall be
Microprocessor based release such as overload,short
circuit,earth fault,neutral protection,etc.
AHU PANEL-1,2,3
100A Amps TPN copper busbars : All the neutral
busbars shall have half the capacity of phase busbars
(1.2A/Sq. mm.).
Design, supply, fixing, testing and commissioning of
cubicle type floor mounting switch board comprising of the
following, the board shall be fabricated as per the detailed
specification enclosed. (Ventilation Panel-1)
INCOMING
200A TPN MCCB 25 KA with connected accessories
1No.as incomer
OUTGOINGS
63A TPN MCCB, 16 KA 8Nos
32A TPN MCCB, 16 KA 2Nos
With necessary copper busbars, interconnections,
providing Digital type voltmeter, ammeter with selector
switches, ON,OFF,TRIP, phase indication lamp, Fuse,
Switch control etc.and also refer the drawing.
The incoming and outgoing breakers shall be
Microprocessor based release such as overload,short
circuit,earth fault,neutral protection,etc.
VENTILATION PANEL-1
200A Amps TPN copper busbars : All the neutral
busbars shall have half the capacity of phase busbars
(1.2A/Sq. mm.).
Design, supply, fixing, testing and commissioning of
cubicle type floor mounting switch board comprising of the
following, the board shall be fabricated as per the detailed
specification enclosed. (Ventilation Panel-2)
INCOMING
200A TPN MCCB 25 KA with connected accessories
1No.as incomer
OUTGOINGS
63A TPN MCCB, 16 KA 4Nos
32A TPN MCCB, 16 KA 8Nos
With necessary copper busbars, interconnections,
providing Digital type voltmeter, ammeter with selector
switches, ON,OFF,TRIP, phase indication lamp, Fuse,
Switch control etc.and also refer the drawing.
The incoming and outgoing breakers shall be
Microprocessor based release such as overload,short
circuit,earth fault,neutral protection,etc.
VENTILATION PANEL-2

Each

Each

Each

Amount in Rs.
In words

S.No.

Description

Qty

Unit

Rate
In Figure

200A Amps TPN copper busbars : All the neutral


busbars shall have half the capacity of phase busbars
(1.2A/Sq. mm.).

Each

Each

Each

Each

Design, supply, fixing, testing and commissioning of


cubicle type floor mounting switch board comprising of the
39
following, the board shall be fabricated as per the detailed
specification enclosed. (Main Lighting Panel)
INCOMING
400A TPN MCCB 35 KA with connected accessories
1No.as incomer
OUTGOINGS
250A TPN MCCB, 25 KA 5Nos
With necessary copper busbars, interconnections,
providing Digital type voltmeter, ammeter with selector
switches, ON,OFF,TRIP, phase indication lamp, Fuse,
Switch control etc.and also refer the drawing.
The incoming and outgoing breakers shall be
Microprocessor based release such as overload,short
circuit,earth fault,neutral protection,etc.
MAIN LIGHTING PANEL
400A Amps TPN copper busbars : All the neutral
busbars shall have half the capacity of phase busbars
(1.2A/Sq. mm.).

40

Design, supply, fixing, testing and commissioning of


cubicle type floor mounting switch board comprising of the
following, the board shall be fabricated as per the detailed
specification enclosed. (Sub Lighting Panel-1,2)
INCOMING
250A TPN MCCB 35 KA with connected accessories
1No.as incomer
OUTGOINGS
32A TPN MCCB, 25 KA 10Nos
With necessary copper busbars, interconnections,
providing Digital type voltmeter, ammeter with selector
switches, ON,OFF,TRIP, phase indication lamp, Fuse,
Switch control etc.and also refer the drawing.
The incoming and outgoing breakers shall be
Microprocessor based release such as overload,short
circuit,earth fault,neutral protection,etc.
SUB LIGHTING PANEL-1,2
250A Amps TPN copper busbars : All the neutral
busbars shall have half the capacity of phase busbars
(1.2A/Sq. mm.).

Design, supply, fixing, testing and commissioning of


cubicle type floor mounting switch board comprising of the
41
following, the board shall be fabricated as per the detailed
specification enclosed. (Sub Lighting Panel-3)
INCOMING
250A TPN MCCB 35 KA with connected accessories
1No.as incomer
OUTGOINGS
32A TPN MCCB, 25 KA 6Nos
With necessary copper busbars, interconnections,
providing Digital type voltmeter, ammeter with selector
switches, ON,OFF,TRIP, phase indication lamp, Fuse,
Switch control etc.and also refer the drawing.
The incoming and outgoing breakers shall be
Microprocessor based release such as overload,short
circuit,earth fault,neutral protection,etc.
SUB LIGHTING PANEL-3
250A Amps TPN copper busbars : All the neutral
busbars shall have half the capacity of phase busbars
(1.2A/Sq. mm.).

Amount in Rs.
In words

S.No.

Description

Qty

Unit

Rate
In Figure

42

Design, supply, fixing, testing and commissioning of


cubicle type floor mounting switch board comprising of the
following, the board shall be fabricated as per the detailed
specification enclosed. (Main Power Panel)
INCOMING
800A TPN MCCB 50 KA with connected accessories
1No.as incomer
OUTGOINGS
400A TPN MCCB, 35 KA 6Nos
With necessary copper busbars, interconnections,
providing Digital type voltmeter, ammeter with selector
switches, ON,OFF,TRIP, phase indication lamp, Fuse,
Switch control etc.and also refer the drawing.
The incoming and outgoing breakers shall be
Microprocessor based release such as overload,short
circuit,earth fault,neutral protection,etc.
MAIN POWER PANEL
800A Amps TPN copper busbars : All the neutral
busbars shall have half the capacity of phase busbars
(1.2A/Sq. mm.).

Each

Each

Each

Design, supply, fixing, testing and commissioning of


cubicle type floor mounting switch board comprising of the
43
following, the board shall be fabricated as per the detailed
specification enclosed. (Sub Power Panel-1)
INCOMING
400A TPN MCCB 35 KA with connected accessories
1No.as incomer
OUTGOINGS
63A TPN MCCB, 16 KA 20Nos
With necessary copper busbars, interconnections,
providing Digital type voltmeter, ammeter with selector
switches, ON,OFF,TRIP, phase indication lamp, Fuse,
Switch control etc.and also refer the drawing.
The incoming and outgoing breakers shall be
Microprocessor based release such as overload,short
circuit,earth fault,neutral protection,etc.
SUB POWER PANEL-1
400A Amps TPN copper busbars : All the neutral
busbars shall have half the capacity of phase busbars
(1.2A/Sq. mm.).

44

45

Design, supply, fixing, testing and commissioning of


cubicle type floor mounting switch board comprising of the
following, the board shall be fabricated as per the detailed
specification enclosed. (Sub Power Panel-2)
INCOMING
400A TPN MCCB 35 KA with connected accessories
1No.as incomer
OUTGOINGS
63A TPN MCCB, 16 KA 14Nos
With necessary copper busbars, interconnections,
providing Digital type voltmeter, ammeter with selector
switches, ON,OFF,TRIP, phase indication lamp, Fuse,
Switch control etc.and also refer the drawing.
The incoming and outgoing breakers shall be
Microprocessor based release such as overload,short
circuit,earth fault,neutral protection,etc.
SUB POWER PANEL-2
400A Amps TPN copper busbars : All the neutral
busbars shall have half the capacity of phase busbars
(1.2A/Sq. mm.).
Design, supply, fixing, testing and commissioning of
cubicle type floor mounting switch board comprising of the
following, the board shall be fabricated as per the detailed
specification enclosed. (Sub Power Panel-3)
INCOMING
400A TPN MCCB 35 KA with connected accessories
1No.as incomer
OUTGOINGS
63A TPN MCCB, 16 KA 12Nos
With necessary copper busbars, interconnections,
providing Digital type voltmeter, ammeter with selector
switches, ON,OFF,TRIP, phase indication lamp, Fuse,
Switch control etc.and also refer the drawing.

Amount in Rs.
In words

S.No.

Description

Qty

Unit

Rate
In Figure

The incoming and outgoing breakers shall be


Microprocessor based release such as overload,short
circuit,earth fault,neutral protection,etc.
SUB POWER PANEL-3
400A Amps TPN copper busbars : All the neutral
busbars shall have half the capacity of phase busbars
(1.2A/Sq. mm.).

46

Each

Each

Each

Design, supply, fixing, testing and commissioning of


cubicle type floor mounting switch board comprising of the
following, the board shall be fabricated as per the detailed
specification enclosed. (UPS Outgoing Panel)
INCOMING
125A TP+2N MCCB 25 KA with connected accessories
1No.as incomer
OUTGOINGS
63A TPN MCCB, 16 KA 8Nos
With necessary copper busbars, interconnections,
providing Digital type voltmeter, ammeter with selector
switches, ON,OFF,TRIP, phase indication lamp, Fuse,
Switch control etc.and also refer the drawing.
The incoming and outgoing breakers shall be
Microprocessor based release such as overload,short
circuit,earth fault,neutral protection,etc.
UPS OUTGOING PANEL
125A Amps TP+2N copper busbars : All the neutral
busbars shall have double the capacity of phase
busbars (1.2A/Sq. mm.).

48

Each

Design, supply, fixing, testing and commissioning of


cubicle type floor mounting switch board comprising of the
following, the board shall be fabricated as per the detailed
specification enclosed. (UPS incoming Panel)
INCOMING
250A TPN MCCB 25 KA with connected accessories
1No.as incomer
OUTGOINGS
125A TPN MCCB, 25 KA 2Nos
63A TPN MCCB, 16 KA 1No
With necessary copper busbars, interconnections,
providing Digital type voltmeter, ammeter with selector
switches, ON,OFF,TRIP, phase indication lamp, Fuse,
Switch control etc.and also refer the drawing.
The incoming and outgoing breakers shall be
Microprocessor based release such as overload,short
circuit,earth fault,neutral protection,etc.
UPS INCOMING PANEL
250A Amps TPN copper busbars : All the neutral
busbars shall have half the capacity of phase busbars
(1.2A/Sq. mm.).

47

Design, supply, fixing, testing and commissioning of


cubicle type floor mounting switch board comprising of the
following, the board shall be fabricated as per the detailed
specification enclosed. (Emergency Lighting Panel)
INCOMING
100A TPN MCCB 25 KA with connected accessories
1No.as incomer
OUTGOINGS
32A TPN MCCB, 16 KA 12Nos
With necessary copper busbars, interconnections,
providing Digital type voltmeter, ammeter with selector
switches, ON,OFF,TRIP, phase indication lamp, Fuse,
Switch control etc.and also refer the drawing.
The incoming and outgoing breakers shall be
Microprocessor based release such as overload,short
circuit,earth fault,neutral protection,etc.
EMERGENCY LIGHTING PANEL
100A Amps TPN copper busbars : All the neutral
busbars shall have half the capacity of phase busbars
(1.2A/Sq. mm.).

Amount in Rs.
In words

S.No.

Description

Qty

Unit

Rate
In Figure

49

50

Design, supply, fixing, testing and commissioning of


cubicle type floor mounting switch board comprising of the
following, the board shall be fabricated as per the detailed
specification enclosed. (Utility Panel)
INCOMING
400A TPN MCCB 35 KA with connected accessories
1No.as incomer
OUTGOINGS
63A TPN MCCB, 16 KA 3Nos
32A TPN MCCB, 16 KA 7Nos
With necessary copper busbars, interconnections,
providing Digital type voltmeter, ammeter with selector
switches, ON,OFF,TRIP, phase indication lamp, Fuse,
Switch control etc.and also refer the drawing.
The incoming and outgoing breakers shall be
Microprocessor based release such as overload,short
circuit,earth fault,neutral protection,etc.
UTILITY PANEL
400A Amps TPN copper busbars : All the neutral
busbars shall have half the capacity of phase busbars
(1.2A/Sq. mm.).
Design, supply, fixing, testing and commissioning of
cubicle type floor mounting switch board comprising of the
following, the board shall be fabricated as per the detailed
specification enclosed. (Lift Panel)
INCOMING
400A TPN MCCB 35 KA with connected accessories
1No.as incomer
OUTGOINGS
32A TPN MCCB, 16 KA 16Nos
With necessary copper busbars, interconnections,
providing Digital type voltmeter, ammeter with selector
switches, ON,OFF,TRIP, phase indication lamp, Fuse,
Switch control etc.and also refer the drawing.
The incoming and outgoing breakers shall be
Microprocessor based release such as overload,short
circuit,earth fault,neutral protection,etc.
LIFT PANEL
400A Amps TPN copper busbars : All the neutral
busbars shall have half the capacity of phase busbars
(1.2A/Sq. mm.).

Each

Each

12

Each

SECTION C : DISTRIBUTION BOARDS


For all items in section-C, the rate includes necessary
connected minor civil works if required and necessary
supports as required at site. No extra payment will be
made for the same.
LIGHTING DISTRIBUTION BOARDS (LDBs) & POWER
DISTRIBUTION BOARDS (PDBs)
Supply, fixing, testing and commissioning of the double

51 door type compartmental Phase segregated 4way


MCCB DB comprising of the following :
40 A FP MCCB 1No. as incomer.
25A DP MCB (C-Curve) with 25A DP ELCB 30mA 3
Nos. as outgoings.
Each 25A DP MCB outgoing consist of 4nos.10A 10KA
SPMCB (C-Curve) in a separate compartment with
necessary phase segregation as required by the Electrical
Inspectorate.
With necessary tinned copper busbars, interconnections,
separate earth bus, separate neutral bus for each phases.
The board shall be powder coated type fixed with
concealed system in wall. The rate shall include
necessary connected civil works like chipping, rough
plastering etc.

Supply, fixing, testing and commissioning of the double

52 door type compartmental Phase segregated 8way


MCCB DB comprising of the following :
63A FP MCCB 1No. as incomer.
63A DP MCB (C-Curve) with 63A DP ELCB 30mA 3
Nos. as outgoings.

Amount in Rs.
In words

S.No.

Description

Qty

Unit

Rate
In Figure

Each 63A DP MCB outgoing consist of 8nos.10A 10KA


SPMCB (C-Curve) in a separate compartment with
necessary phase segregation as required by the Electrical
Inspectorate.
With necessary tinned copper busbars, interconnections,
separate earth bus, separate neutral bus for each phases.
The board shall be powder coated type fixed with
concealed system in wall. The rate shall include
necessary connected civil works like chipping, rough
plastering etc.

34

Each

Each

Each

Each

15

Each

EXTERNAL LDB for Street lighting (Vertical TPN DB)


Supply, fixing, testing and commissioning of the double

53 door type VTPN 4way MCCB DB comprising of the


following :
125A 4P MCCB 25KA with ELM and all other required
accessories 1 No. as incomer with timer & contactor.
32A 4P MCB 10KA 4 Nos. as outgoings.
With necessary tinned copper busbars, interconnections,
earth bus, neutral bus. The board shall be powder coated
type fixed with concealed system in wall. The rate shall
include necessary connected civil works like chipping,
rough plastering etc.

54 UPS DB (7 segment DB)


Supply, fixing, testing and commissioning of the double
door type compartmental Phase segregated 8way
MCCB DB comprising of the following :
63 A TP+2N MCCB 1 No. as incomer.
63A DP RCBO Type-A with D-Curve 30mA 3 Nos. as
outgoings.
Each 63A DP RCBO outgoing consist of 8nos.6/16A 10
KA SPMCB (D-Curve) in a separate compartment with
necessary phase segregation as required by the Electrical
Inspectorate.
With necessary tinned copper busbars, interconnections,
separate earth bus, separate neutral bus for each phases.
The board shall be powder coated type fixed with
concealed system in wall. The rate shall include
necessary connected civil works like chipping, rough
plastering etc.
Supply, fixing, testing and commissioning of the double

55 door type VTPN 4way MCCB DB comprising of the


following :
40 A 4P MCCB 25KA with ELM and all other required
accessories 1 No. as incomer
16/20A 4P MCB 10KA 4 Nos. as outgoings.
With necessary tinned copper busbars, interconnections,
earth bus, neutral bus. The board shall be powder coated
type fixed with concealed system in wall. The rate shall
include necessary connected civil works like chipping,
rough plastering etc.
Supply, fixing, testing and commissioning of the double

56 door type VTPN 8way MCCB DB comprising of the


following :
63A 4P MCCB 25KA with ELM and all other required
accessories 1 No. as incomer
16/20A 4P MCB 10KA 8 Nos. as outgoings.
With necessary tinned copper busbars, interconnections,
earth bus, neutral bus. The board shall be powder coated
type fixed with concealed system in wall. The rate shall
include necessary connected civil works like chipping,
rough plastering etc.

SECTION D : WIRING AND CONNECTED


ACCESSORIES

Amount in Rs.
In words

S.No.

Description

Qty

Unit

Rate
In Figure

For all items in section-D, the rate includes necessary


connected minor civil works if required and necessary
supports as required at site. No extra payment will be
made for the same.
Note : ALL POINT WIRING FOR LIGHT / FAN / PLUG
POINTS SHALL INCLUDE COST OF CIRCUIT MAINS.
NO EXTRA PAYMENT WILL BE MADE FOR THE SAME.
Wiring to the light points /6A plug point using 3 X 1.5
sqmm multi strand PVC insulated copper conductor
(FRLS) with ROHS compliant in suitable size GI pipe in
57.00 open system in above false ceiling and concealed system
in below false ceiling on wall/column etc. The rate should
inclusive of supply and fixing of 6A modular type switch in
a suitable size modular box etc.

One light controlled by one switch

115

Point

Two light controlled by one switch

210

Point

Three light controlled by one switch

160

Point

Four light controlled by one switch

20

Point

Five light controlled by one switch

Point

6A socket controlled by 1no 6A switch

30

Point

Wiring to the exhaust fan points using 2 X 2.5 sqmm and


1 X 1.5 sqmm multi strand PVC insulated copper
conductor (FRLS) with ROHS compliant in suitable size GI
pipe in open system in above false ceiling and concealed
58
system in below false ceiling on wall/column etc. The rate
should inclusive of supply and fixing of 6A modular type
switch in a suitable size modular box etc. (Average length
of point - 12 mtr)

10

Point

Wiring to the 6/16A 5Pin or 6Amps UPS/Raw power


socket using 2 X 2.5 sqmm and 1 X 1.5 sqmm multi
strand PVC insulated copper conductor (FRLS) with
59
ROHS compliant in suitable size GI pipe in open system
above false ceiling and concealed system in below false
ceiling in wall / column etc.

5000

R.M

Each

10

Each

1000

R.M

60

Supply, fixing, testing and commissioning of 1No. 16/20A


modular socket for UPS or Raw Power supply and

switch combination in a suitable size modular box in


recessed system. (16/20A socket controlled by 1 Switch)

Design, supply and fixing of 20A 3 pin metal clad socket

61 with 20A DP MCB in a suitable size MS enclosure fixed in


recessed system. (Mancooler)

Wiring to the power plugs using 3 Runs of 4 sq.mm pvc

62 insulated (FRLS) armoured copper cable in wall /


column etc. (for 20A metal clad socket with 20A DP MCB)

Amount in Rs.
In words

S.No.

Description

Qty

Unit

Rate
In Figure

Supply and laying of following size PVC/GI conduits in


floor / wall /ceiling etc. including necessary
63 bends,elbow,etc, in concealed system below the false
ceiling on wall/floor and open system on above false
ceiling.(for Telephone/Data cabling etc.)
Supply and laying of following runs of PVC insulated
copper conductor (FRLS) with ROHS compliant in existing
64 floor trunking. The rate shall be inclusive of civil works
such as chipping, plastering with chicken mesh and
finished to match with the original surface.

1 X 1.5 Sq.mm copper conductor

200

R.M

1 X 2.5 Sqmm copper conductor

200

R.M

2 X 2.5 Sqmm copper conductor

250

R.M

3 X 2.5 Sq.mm copper conductor

500

R.M

3 Core X 2.5 Sq.mm copper conductor

300

R.M

3 Core X 4.0 Sq.mm copper conductor

300

R.M

Supply, fixing of the 100 x 45 mm aluminium Channel


(Raceways) including stiffner at required intervals in
recessed system in floor including cutting chippling,
65
plastering in the floor/wall to make good finish to match
with the floor /wall etc. (Thickness: 2mm for Top & Base
and 1.6mm for sides)

250

R.M

Supply, fixing of the 50x 25 mm aluminium Channel


(Raceways) including stiffner at required intervals in
recessed system in floor including cutting chippling,
66
plastering in the floor/wall to make good finish to match
with the floor /wall etc. (Thickness: 2mm for Top & Base
and 1.6mm for sides)

100

R.M

Supply, fixing of the 300 x 40 mm aluminium Channel


(Raceways) including stiffner at required intervals in
recessed system in floor including cutting chipping,
67
plastering in the floor/wall to make good finish to match
with the floor /wall etc. (Thickness: 2mm for Top & Base
and 1.6mm for sides)

20

R.M

68

Supply fixing of the 150 x 150 x 50 mm floor junction box


with necessary civil works fixed in recessed system in
floor including cutting chippling, plastering in the floor/wall
to make good finish to match with the floor/ wall etc.

Each

69

Supply fixing of the 250 x 250 x 50 mm floor junction box


with necessary civil works fixed in recessed system in
floor including cutting chippling, plastering in the floor/wall
to make good finish to match with the floor/ wall etc.

15

Each

70

Supply fixing of the 350 x 350 x 50 mm floor junction box


with necessary civil works fixed in recessed system in
floor including cutting chippling, plastering in the floor/wall
to make good finish to match with the floor/ wall etc.

10

Each

Amount in Rs.
In words

S.No.

Description

Qty

Unit

Rate
In Figure

71

Supply and fixing of RJ45 Data socket with suitable


modular plate and metal box.

72 Supply and fixing of Wi-fi point

35

Each

35

Each

105

Each

Supply and fixing of floor boxes 10 modules similar to

73 Legrand Mosaic cat.no 089620 or equivalent with all


accessories and the following combination.

2Nos.6/16A Raw power socket controlled by 1No.Switch


2Nos.6/16A UPS power socket controlled by 1No.Switch

1No.Data socket and 1No.Voice socket

SECTION E : CABLES AND TERMINATION


For all items in section-D, the rate includes necessary
connected minor civil works if required and necessary
supports as required at site. No extra payment will be
made for the same.
Supply, laying of following size XLPE (FRLS) insulated
outer sheathed (1100 V grade) aluminium / copper,
armoured / unarmoured conductor cable (with ROHS
74
compliance if any) partly laid in existing cable tray and
partly laid in wall/ ceiling with suitbale clamps. Cable tray
will be measured and paid separately.

3.5 Core X 400 Sq.mm XLPE Aluminium armoured Cable

1500

R.M

3.5 Core X 300 Sq.mm XLPE Aluminium armoured Cable

200

R.M

3.5 Core X 240 Sq.mm XLPE Aluminium armoured Cable

50

R.M

3.5 Core X 185 Sq.mm XLPE Aluminium armoured Cable

50

R.M

3.5 Core X 150 Sq.mm XLPE Aluminium armoured Cable

200

R.M

3.5 Core X 120 Sq.mm XLPE Aluminium armoured Cable

300

R.M

3.5 Core X 95 Sq.mm XLPE Aluminium armoured Cable

200

R.M

3.5 Core X 70 Sq.mm XLPE Aluminium armoured Cable

100

R.M

3.5 Core X 50 Sq.mm XLPE Aluminium armoured Cable

100

R.M

3.5 Core X 35 Sq.mm XLPE Aluminium armoured Cable

100

R.M

4 Core X 25 Sq.mm XLPE Aluminium armoured Cable

3500

R.M

Amount in Rs.
In words

S.No.

Description

Qty

Unit

Rate
In Figure

4 Core X 16 Sq.mm XLPE Aluminium armoured Cable

4000

R.M

4 Core X 10 Sq.mm XLPE Copper armoured Cable

50

R.M

4 Core X 6 Sq.mm XLPE Copper armoured Cable

50

R.M

4 Core X 4 Sq.mm XLPE Copper armoured Cable

50

R.M

4 Core X 2.5 Sq.mm XLPE Copper armoured Cable

50

R.M

1 Core 25 Sq.mm XLPE Copper armoured Cable

50

R.M

24 Core X 2.5 Sq.mm XLPE Copper armoured Cable

50

R.M

12 Core X 2.5 Sq.mm XLPE Copper armoured Cable

50

R.M

75

Supply and termination of the following size cables with


suitable double compression glands with suitable crimping
socket. (copper sockets for copper cables and Alu.
Sockets for alum. Cable)

4 Core X 10 Sq.mm PVC Copper armoured Cable

Each

b.

4 Core X 6 Sq.mm PVC Copper armoured Cable

Each

4 Core X 4 Sq.mm PVC Copper armoured Cable

Each

4 Core X 2.5 Sq.mm PVC Copper armoured Cable

Each

1 Core 25 Sq.mm PVC Copper Unarmoured Cable

Each

24 Core X 2.5 Sq.mm PVC Copper Unarmoured Cable

Each

12 Core X 2.5 Sq.mm PVC Copper Unarmoured Cable

Each

SECTION - F

76

50 x 10mm Copper flat for Transformer Neutral. The joints


shall be provided with Rivet/ bracing

30

R.M

77

50 x 6mm Copper flat for DG Neutral. The joints shall be


provided with Rivet/ bracing

50

R.M

Amount in Rs.
In words

S.No.

Description

Qty

Unit

Rate
In Figure

78

40 x 6 mm Copper flat for Transformer body and HT panel


body. The joints shall be provided with Rivet / bracing

100

R.M

79

25 x 6mm Copper flat for Subpanels. The joints shall be


provided with Rivet/ bracing

150

R.M

80

25 x 3mm Copper flat for Subpanels. The joints shall be


provided with Rivet/ bracing

250

R.M

81

Design, cutting, and fixing of 9mm thick chequered plate


with required MS angles.

20

Sq.mtr

Supply and Installation of MS flat / angle iron supports for


various purpose if required with various sizes including
cutting,welding,grinding,fixing accessories and one coat of
10
82
primer & two coats of enamel paints, minor civil works etc.
as required.(Note: The flat / angle iron weight will be
arrived on the basis of theoretical calculation only).

MT

SECTION G : CABLE TRAYS


Supply, erection of following sizes GI ladder / perforated

83 type cable rack system made out of sheet steel folded to


required shape with adequate number of supports.
The cable rack shall have runners rugs of suitable size,
horizontal elbow, vertical elbow 90 Deg. Up vertical elbow
90 Deg. Down, re-deep, coupler plates, materials.The
cable racks shall be suspended from ceiling supported
from side walls in columns etc. with adequate size
supporting angles / channels with fastners, welding,
anchor bolts, nuts etc. The rack shall have suitable cable
clamping arrangements etc. The metal rack system shall
be treated with one coat of rubber based polyvinyl paint as
primer and finished with two coats of green enamel paint
complete with all civil works for fabrication details. Refer
enclosed drawing.
The rate shall be inclusive of thread rod/gripple/steel
support with one coat of primer & two coats of enamel
paints and all accesories to fix the hangers at
purlin,rafter,beam,wall
and ceiling
with
required
clamps,anchor fastener,nuts & bolts to be considered.This
support spacing and fixing as per standards. The height of
the hanging arrangement shall be as per drawing.

83.1 Perforated type


a

75mm x 40mm x 2.0 mm

100

R.M

100mm x 50mm x 2.0mm

100

R.M

150mm x 50mm x 2.0mm

150

R.M

300mm x 75mm x 2.5mm

200

R.M

Amount in Rs.
In words

S.No.

Description

Qty

Unit

Rate
In Figure

450mm x 75mm x 2.5mm

100

R.M

600mm x 75mm x 2.5mm

200

R.M

750mm x 75mm x 2.5mm

150

R.M

1000mm x 75mm x 2.5mm

150

R.M

83.2 Laddertype
a

600mm x 75mm x 2.5mm

200

R.M

750mm x 75mm x 2.5mm

200

R.M

1000 mm x 75mm x 2.5mm

200

R.M

SECTION H : Safety Equipments

84

Supply and laying of 20mm thick 1000mm wide chequered


rubber mat with ISI mark suitable for 11KV installation .

10

Sq.mtr

85

Supply and laying of 12mm thick 1000mm wide chequered


rubber mat with ISI mark suitable for 440V installation .

40

Sq.mtr

86

Supply and fixing of HT/LT cable route indicator made out


of MS flat and angle iron.

60

Each

Each

Each

89 Supply of tested hand gloves of 11KV grade.

Each

Supply and fixing of GI fire buckets with round bottom,


each set comprising 4Nos.fire buckets of 9Kg capacity
including supply of M.S pedestal stand with hooks suitable
90
for holding of 4Nos of fire buckets, painted with Post
Office Red oil paint and letter FIRE on each bucket and
filling with sand complete as required

Each

Supply and erection of fire extinguisher Co2 4.5 Kg.


confirm to IS norms.

10

Each

Supply and providing first aid box 18SWG MS sheet duly

87 painted as approved by Indian red cross soceity complete


with all first aid medicines.
Supply and providing shock treatment chart in English,

88 Hindi duly framed with 2mm thick glass in front & 6mm
thick ply on backas required

91

Amount in Rs.
In words

S.No.

Description

Qty

Unit

Rate
In Figure

92

Supply & Fixing of Artificial Respirator for Inspiration with


chart showing the use of it.

Each

Supply,Installation,Testing and commissioning of the


Advanced Lightning Protection Stormaster ESE Air
Terminal with all accessories required for its proper
93 functioning. The elevated pole should be fitted firmly
attached to the wall or coloumn with suitable guy wire
system as per manufacturer recommendations to be
provided.

Each

Supply,Installation,Testing and commissioning of the


HVSC down conductor shall be consists of copper
conducors, inner insulation, outer copper conductor,
conductive sheaths, all cencentrically arrangements outer
diameterr of the down conductor shall be less than 37mm.
94
The main conductor cross sectional area is 50 sq.mm The
down conductor shall be placed minimum wall thickness
and minimum bending radius is 0.5m.The down conductor
50 sq.mm / 37mm / OD weight is 2.050 kg per Meter with
all fastening with tape clip etc.

160

Each

Supply,Installation,Testing and commissioning of the


Lightning Strike Recorder designed for easy mounting
on the down conductor to effectively count the number of
95 liightning strikes captured by the air terminal. The recorder
sensitive range of 1500 amps to a maximum of 220KA @
8/20s. The recorder is self powered and does not require
the use of battery or any other external power source etc.

Each

Supply,Installation,Testing and commissioning of efficient


earthing system with copper bonded earth rod, Clamp,
96 Copper Tape, Ground Resistance Improvement powder all
as required including excavation of earth etc as required
as per manufacture recommendation.

Each

10

Each

Each

Each

SECTION - I : LIGHTNING PROTECTION SYSTEM


For all items in section-H, the rate includes necessary
connected minor civil works if required and necessary
supports as required at site. No extra payment will be
made for the same.

SECTION J : External Works


For all items in section-I, the rate includes necessary
connected minor civil works if required and necessary
supports as required at site. No extra payment will be
made for the same.
PHILIPS Alpha Power with AC 1x24 CREE XPG OR
97
Equivalent
Supply and erection of IP65 LED SOLAR streetlight
Luminaire of not more than 21W (System wattage)
complete with pressure die cast aluminum housing also
adhering to the specifications attached

98 PHILIPS CPP 745 OR Equivalent


Leonardo decorative post top lantern made of die cast
aluminium housing with high corrosion resistance with
high finish extruded aluminium column with base flange
and IP55 protection for dust and jet proofing
Lamp: 1 x SON 70W

99 PHILIPS CPP 735


Regina Indirect light decorative post top lantern made of
die cast aluminium housing of canopy with high corrosion
resistance with high finish extruded aluminium column with
base flange and IP65 protection for dust and jet proofing
alongwith extruded aluminium pole and suitable for metal
halide lamp

Amount in Rs.
In words

S.No.

Description

Qty

Unit

Rate
In Figure

Lamp: 1 x CDM-T 70W


SECTION K : Miscellaneous

100

Supply, Installation, Testing and commissioning of the 30


kVA UPS system 3 phase input and three phase output
and as per the detailed specification enclosed.(For
computers & other essential loads) including
Supply, Installation, Testing and Commissioning of Sealed
Maintenance Free Batteries to support 30KVA for 15
minutes complete with intercell connectors & copper
cables, battery stand made out of Powder Coated MS
Angles with adequate supports to carry the load of the
batteries.
The vendor shall submit dimensional GA drawing of
complete UPS system, battery rack with batteries,
Service bypass Panel and Battery bank calculations
along with offer.

Each

Each

Towards professional charges for filing application,


Liasioning with state Electricity Board for getting the three
102 phase HT/LT connection, follow up with State electricity
board, getting the load sanction, load release letter,
commissioning the installation. The rate shall includes
arranging inspection (if required) at site.

LS

Towards professional charges for preparation of drawings


in necessary formats for approval, follow up and arranging
approval of drawings, scheme by Local electricity authority
/ Electrical Inspectorate, arranging inspection, obtaining
safety certificate clearance from electrical Inspectorate for
103
the installation and arranging power connection. The Rate
shall be including preparation and submission of as built
drawings of entire installation of the works executed need
to be submitted in the blue print of A1 size as required in 6
Sets of hard copy and two set sets of soft copy in CD.

LS

Supply, Installation, Testing and commissioning of the 20

101 kVA UPS system 3 phase input and three phase output

and as per the detailed specification enclosed.(For


Emergency Lighting) including
Supply, Installation, Testing and Commissioning of Sealed
Maintenance Free Batteries to support 20KVA for 15
minutes complete with intercell connectors & copper
cables, battery stand made out of Powder Coated MS
Angles with adequate supports to carry the load of the
batteries.
The vendor shall submit dimensional GA drawing of
complete UPS system, battery rack with batteries,
Service bypass Panel and Battery bank calculations
along with offer.

TOTAL MARKET AMOUNT

DG WORKS

Amount in Rs.
In words

S.No.

Description

Qty

Unit

Rate
In Figure

Design, Manufacture, Transportation, Supply, Installation,


Testing and Commissioning of factory assembled and
factory tested, water cooled, turbo charged after cooled
diesel engine alternator set capable of generating full load
of minimum 625 KVA DG set, 1500 rpm, four stroke, with
acoustic enclosure, designed for operating on HSD, 415V,
50 Hz, 0.8 pf, complete with all accessories, like base
frame, residential silencer, radiator, alternator capable of
delivering 415 Volts, 50Hz, 3 phase, PF 0.8, 625 KVA
load (minimum), coupling arrangement of alternator with
engine, coupling guard, water pump, oil pump, fuel filter,
5.00 oil filter, air filter, exhaust flexible piping, fuel tank of 990
litres, fuel transfer hand pump with suitable hose pipe
batteries 24V and 200 AH capacity, battery charging
alternator, engine control panel, anti-vibration mounting
suitable for starting of the DG Set with standard control
panel and includes the following transport, insurance,
handling, safe keeping at site etc., erection, installation,
testing and commissioning including performance tests as
per Specifications. The necessary foundation will be
provided by other agency.

Each

Supply,Installation, Testing and Commissioning of AMF


with Auto Synchronising control panel with Auto Load
sharing arrangement of indoor, floor mounting type with 2
Nos. 1000Amps, TP, 50KA, EDO type, air circuit breaker
with shunt release, shutter assembly, door interlock and
other required accessories and 400Amps,4 pole, neutral
6.00 isolating contactor as incoming with complete set of
instrument
panel
with
accessories,
protection
release/relays etc. and 1No. 2000Amps, 4Pole, 65KA,
EDO type, air circuit breaker with shunt release, shutter
assembly, door interlock and other required accessories
as outgoing feeders with complete set of instrument panel
with accessories, protection release/relays etc.

Each

Supply and Laying of 40mm x 6mm copper flat from earth


electrode in 40mm dia B class GI, directly in ground
including earth work excavation, refilling the trench, with
7.00
all accessories, jointing the flats with lap joint with 2Nos.
of bolt/nuts/spring washers/check nuts completed etc. as
required.(For Netural earthing)

200

R.M

Supply and laying of No 8 SWG (4.0mm dia) copper wire


on surface or in recess for loop earthing etc. as required.

50

R.M

Supply and Laying of 25mm x 3mm copper flat on surface


or in recess for generator body earthing, jointing the flats
9.00 with lap joint with 2Nos. of bolt/nuts/spring washers/check
nuts completed etc. as required.(For Body earthing &
ligtning spike)

150

R.M

Supply and fixing of 8" dia MS exhaust pipe class B


suitable for 625 KVA engine exhaust line including with
all accessories such as bends,.flanges, gaskets,
condensation removal plug, fixing of flexible coupling,
residential silencer supplied along with the engine.
Providing necessary MS angle iron supports for the pipe
10.00 line and the silencer, welding arrangements/ flanged joints
with bolts/nuts as per the site conditions. Terminating the
pipe line/ ducting in scrubber and chimney including the
complete pipe line/ duct of insulation with 50mm thick
glass wool, polythene covering,chicken mesh and
aluminium cladding complete as per the specifications
etc. as required.

20

R.M

11.00 Supply and fixing of 12" dia MS exhaust pipe class B

40

R.M

Each

8.00

12.00

Supply & fixing of 50mm thick glass wool insulation for the
625KVA engine residential silencer including cutting, fixing
of glass wool, chicken mesh and aluminium cladding
complete as per the specifications etc. as required.

Amount in Rs.
In words

S.No.

Description

Qty

Unit

Rate
In Figure

13.00

Supply & fixing of 50mm thick glass wool insulation for 8"
dia MS exhaust pipe class B including cutting, fixing of
glass wool, chicken mesh and aluminium cladding
complete as per the specifications etc. as required.

40

R.M

14.00

Supply & fixing of 50mm thick glass wool insulation for 12"
dia MS exhaust pipe class B including cutting, fixing of
glass wool, chicken mesh and aluminium cladding
complete as per the specifications etc. as required.

60

R.M

Supply and laying of 25mm dia , B class MS pipe, fuel line


for the interconnection of the reserve tanks to day tank
and day tank to engine i/c. fuel transfer pumps with all
15.00 accessories such as bend,elbow, coupling, union,
plugs,flanges,bolts/nuts,gaskets,
making
threaded
ends/welding as per the site condition laying in the
following manner etc. as required.

In the exposed surface the pipe line shall be painted with


one coat of primer and two coats of synthetic enamel paint
i/c. with necessary supports complete as required.

30

R.M

In soil , below 0.5 Mtrs from the ground level , the pipe
line shall be painted with one coat of hot
bitumen,wrapping with 3 layers of hessian cloth dipped in
hot bitumen i/c. with necessary supports complete etc. as
required.

30

R.M

16.00

Supply and fixing the following size of valves in the


existing 25mm dia MS pipe line i/c. cutting,
threding,welding,grinding, fixing,painting etc. as required
(ISI marked make)

25mm dia brass gun metal Ball valve

Each

25mm dia brass gun metal NRV valve

Each

Each

Supply and fixing of outdoor fuel day tank made up of MS


sheet,
990
ltrs
capacity
i/c.
cutting,
welding,grinding,providing inlet,outlet, overflow, drain, air
vent, inlet fuel filter, fuel level indicator with scale, fuel
17.00
level switch for level monitoring through IBMS, painting,
fixing with suitable size MS angle iron frame work on the
existing foundation etc. as required. (Excluding cost of
foundation).
Supply, laying of following size XLPE (FRLS) / PVC
(FRLS) insulated outer sheathed (1100 V grade)
Aluminium / Copper armoured conductor (with ROHS
18.00
compliance if any) cable partly laid in existing cable tray
and partly laid in wall/ ceiling with suitbale clamps. Cable
tray will be measured and paid separately.

3.5 Core X 400 Sq.mm PVC Aluminium XLPE armored


Cable laying through trench (trench will be made by other
agency)

200

R.M

16 Core X 2.5Sq.mm PVC sheated XLPE Copper


armoured Cable

100

R.M

4 Core X 2.5 Sq.mm PVC sheated XLPE Copper


armoured Cable

200

R.M

6 Core X 2.5 Sq.mm PVC sheated XLPE Copper


armoured Cable

150

R.M

24 Core X 2.5 Sq.mm PVC sheated XLPE Copper


armoured Cable

100

R.M

Amount in Rs.
In words

S.No.

Description

Qty

Unit

Rate
In Figure

4 Core X 4 Sq.mm PVC sheated XLPE Copper armoured


Cable

100

R.M

Supply and termination of the following size cables with


suitable double compression glands with suitable crimping
19.00 socket. (Copper sockets for Copper cables and
Aluminium Sockets for Aluminium Cable)

16 Core X 2.5Sq.mm PVC Copper armoured Cable

Each

4 Core X 2.5 Sq.mm PVC Copper armoured Cable

Each

6 Core X 2.5 Sq.mm PVC Copper armoured Cable

Each

24 Core X 2.5 Sq.mm PVC Copper armoured Cable

Each

4 Core X 4 Sq.mm PVC Copper armoured Cable

Each

20.00

Each

Design, Manufacture, Supply and Fixing G.I flanges of


approved make with IRI washers including making holes,
21.00 fixing in position to threaded ends of pipes using MS bolts,
nuts and washers etc. and testing as per IS specification
and as directed.

Each

Each

10

R.M

Design, supply and fixing of copper lightning spike at the


top of the stack with suitable supports.

22.00 Supply and Providing of following items.


Fuel unloading hand pump.
a
PVC Hose - 10 mtrs.
b

Total AMOUNT OF DG WORKS

SOLARWORKS
Design , supply, erection, testing and commisioning of
100Kwp solar hybrid power pack system complete with all
accessories. (Refer Technical specification for details)

Job

TOTALAMOUNTOFSOLARWORKS

HVACWORKS
A

WATER COOLED SCREW CHILLERS


Supply, customs clearance, freight up to site,
Insurance, delivery, hoisting, installing, testing and
commissioning the following items as shown on the
equipment data and drawing for complete and
satisfactory operation and control and to local
authorities approval

Amount in Rs.
In words

S.No.

Description

Qty

Unit

Rate
In Figure

Supplying, installation, testing and commissioning of


WATER COOLED SCREW CHILLER complete with
screw compressors, motor, water cooled condenser,
insulated chiller, flow switch at chiller and condenser,
vibration isolators, integral refrigerant piping and wiring,
accessories as required and called for, automatic and
safety controls mounted in central console panel and all
mounted on a steel frame etc. Motor shall be suitable for
Indian Conditions and operating on 41510% 50 cycles. 3
phase AC supply. Chiller for air conditioning system shall
be selected on the basis of New Delhi ambient condition.
Refrigerant used shall be Ozone friendly HFC R134a as
per specifications. Chillers capacity of each chilling unit
will be as follows:
Chiller Capacity : 190 TR (actual capacity)
Evaporator Side:
Water in : (+) 12 Deg C
Water Out : (+) 7 Deg C
Fouling factor : 0.0001 FPS units
Condenser Side:
Water in : (+) 32 Deg C
Water Out : (+) 36 Deg C
Fouling factor : 0.00025 FPS units
2

Necessary sockets and nipples with suitable brass thermo


well for mounting sensors / transmitters on pipe line to
interface the BMS system.

Nos.

Lot

Nos.

Nos.

Total carry over to summary (Chillers)


B

CHILLED WATER AND CONDENSER WATER PUMPS

To design, supply, installation, testing and


commissioning of the following items as shown on
the equipment data and drawings for complete and
satisfactory operation and control and to local
authorities approval.
Energy efficient, BAS interfacing type, End Suction Long
Coupled Base Mounted chilled water circulation pumpset
having required capacity against the selected head with
C.I. casing, bronze impeller mechanical seal, Internal Selfflushing type, stainless steel shaft sleeve, integral motors
complete with Factory made weather cowl, acoustic box,
drive guard, 25x25x3 mm thick nosing angle frame floating
fountation with spring isolator as per specification.

All pumps shall be factory aligned. The pump motor shall


be suitable for 415V+/- 10% Volts, 50 +/- 5% Hz, +/- 10%
combined voltage and frequency variation, 3 phase AC
power supply. The quoted price shall include cost of
thermal insulation and Aluminium cladding and required
length of power cable from the starter panel. Motor shall
be TEFC Class F and temperature rise restrict to Class
B insulation IP55 protection and Minimum pump hydraulic
efficiency shall be 75%

Primary Vary Flow Chilled water pumps


Type : End Suction Centrifugal Pumps
Flow : 456 USGPM
Temp range: (-)5Deg C upto 45 Deg C
Total Head: 35 Mtr
Condenser water pumps (Constant flow)
Type : End Suction Centrifugal Pumps
Flow : 650 USGPM
Temp range: (-)5Deg C upto 45 Deg C
Total Head: 20 Mtr

Amount in Rs.
In words

S.No.

Description

Qty

Unit

Rate
In Figure

Design, supply, Fabrication, installation, testing and


commissioning of Pump Logic Control Panel consists of
Variable speed drives (Frequency controller and auto
bypass) VFD panels for the above primary vary flow
chilled water pump sets complete with necessary pressure
sensors/transmitters/
temperature
sensor/flow
meter/switch, Microprocessor based pump logic controller,
suitably integrated with adjustable frequency drive in a
single enclosure and capable to control necessary AFD for
multiple pump sets. Parallel pump software duly
downloaded and integrated with pump system. VFD
panels shall be supplied with mounting frames and power
wires / control wiring between pump motor, AFD and
pump logic controller. The integrated power cabling and
control wiring between adjustable frequency driver and
logic controller panel and for sensor shall be included in
the cost.

CHW pump 3 VFD - 2 Working + 1 Standby

Lot

Nos.

Pump design parameter furnished in the BOQ and in


the specification is of indicative in nature. If the actual
parameter required to meet the proposed primary vary
flow chilled water system and constant flow
condenser water system, then the same shall be
provided by AC Contractor based on the final
selection without any cost implication to the Owner.

Total carry over to summary (Chilled water,Condenser


water pumps)
COOLING TOWER
Supplying, installing, testing and commissioning of Cross
Flow or counterflow, Induced Draft, Vertical Discharge
Type, Single / Multicell, FRP Cooling Tower complete with
motor, fan, other complete accessories as described in the
technical specifications. It shall be designed with high
efficiency drift eliminator. Each tower cell must be
installed with individual cold water basins and water
discharge sumps to facilitate maintenance without causing
disruption to the other cells in operation. All piping
connections to the disribution basin should be made of
steel and not from PVC. Vibration Isolators of spring open
type designed to minimise any vibration from transmitting
to other structures to be included in the scope of supply.
Motors shall be suitable for 415 + 10%volt, 50 cycles
3phase power supply. Isolators at cooling tower enclosed
in weather proof panel shall also be included. Tower for
air conditioning system shall be selected on the basis of
New Delhi ambient condition and the Tower shall be CTI
certified.
Chiller Capacity
Cooling tower Capacity
Water Flow Rate

: 190 TR
: 240 TR (min)
: 650 USGPM

Water Temp In
: 36 o C
Water Temp Out
: 32 o C
Total carry over to summary (Cooling tower)

D
1

AIR HANDLING UNITS & TFA UNITS


AIR HANDLING UNITS - FLOOR MOUNTED TYPE

Amount in Rs.
In words

S.No.

Description

Qty

Unit

Rate
In Figure

Supply, installation, testing and commissioning of Double


Skin Air Handling Units of Horizontal / Vertical
Configuration (suitable to the available AHU room), filter
section, Chilled water coil, Electric Strip Heaters, Fan
section, High efficiency motor, Low leak volume control
damper, Flexible connections, Aluminium base frame
complete as per specifications as required. All sheet metal
cabinet type air handler complete with coil section with
cooling coil of 6 row or 8 row deep (copper tube and
aluminium fins construction), fan section with centrifugal
fans motor belt drive, belt guard, vibration isolators,
thermostat, humidistat, canvass connections and with
control panel as per specification and cabling from panel
to motors etc.

The price quoted shall also include the following.


a) All internal wiring, power cabling, copper earthling of
air handling unit motors, from the local control panel and
control wiring
b) Bimetallic lugs shall be used at copper to aluminium
joints.
c) special acoustic treatment to achieve the desire noise
level
d) Accessories and associated wiring between fire
damper panel to fire damper and AHU motor to close fire
dampers and shut-off AHU motor in the case of fire. wiring
between marine light and limit switch.
AHU Specifications:
Cooling Capacity
: 38.0 TR
Dehumidified air quantity : 21500 CFM
Electric Strip Heaters
: 15 kW x 3 Nos
Fan Ex. static pressure
: 1.5 Inch.Wg
Max motor rating
: 15 kW
Cooling Capacity
: .38.0 TR
Dehumidified air quantity : 15950 CFM
Electric Strip Heaters
: 15 kW x 3 Nos
Fan Ex. static pressure
: 1.5 Inch.Wg
Max motor rating
: 11 kW
Cooling Capacity
: .27.0 TR
Dehumidified air quantity : 10500 CFM
Electric Strip Heaters
: 10 kW x 3 Nos
Fan Ex. static pressure
: 1.0 Inch.Wg
Max motor rating
: 7.5 kW
Cooling Capacity
: .27.0 TR
Dehumidified air quantity : 9000 CFM
Electric Strip Heaters
: 10 kW x 3 Nos
Fan Ex. static pressure
: 1.0 Inch.Wg
Max motor rating
: 5.5 kW
Cooling Capacity
: 34.0 TR
Dehumidified air quantity : 20600 CFM
Electric Strip Heaters
: 14 kW x 3 Nos
Fan Ex. static pressure
: 1.5 Inch.Wg
Max motor rating
: 15 kW
Cooling Capacity
: 30.0 TR
Dehumidified air quantity : 14750 CFM
Electric Strip Heaters
: 9 kW x 3 Nos
Fan Ex. static pressure
: 1.25 Inch.Wg
Max motor rating
: 11 kW
Cooling Capacity
: 30.0 TR
Dehumidified air quantity : 17150 CFM
Electric Strip Heaters
: 8 kW x 3 Nos
Fan Ex. static pressure
: 1.5 Inch.Wg
Max motor rating
: 11 kW
Cooling Capacity
: 30.0 TR
Dehumidified air quantity : 15550 CFM
Electric Strip Heaters
: 8 kW x 3 Nos
Fan Ex. static pressure
: 1.5 Inch.Wg
Max motor rating
: 11 kW
Cooling Capacity
: 20.0 TR
Dehumidified air quantity
: 10050 CFM
Electric Strip Heaters
: 2.5 kW x 3 Nos
Fan Ex. static pressure
: 1.0 Inch.Wg
Max motor rating
: 7.5 kW

Nos.

Nos.

Nos.

Nos.

Nos.

Nos.

Nos.

Nos.

Nos.

Amount in Rs.
In words

S.No.

Description

Qty

Unit

Rate
In Figure

Cooling Capacity
Dehumidified air quantity
Electric Strip Heaters
Fan Ex. static pressure
Max motor rating

: 20.0 TR
: 8750 CFM
: 2.5 kW x 3 Nos
: 1.0 Inch.Wg
: 5.5 kW

Nos.

Nos.

Nos.

Some other Specifications: (Common for all AHUs)

Design apparatus dew point - 12 Deg C


Chilled water entry temperature - 7 Deg C
Chilled water leaving temperature - 12 Deg C
Chilled water Flow - 2.4 GPM per TR
Filter Section
MERV 8 FILTERS DURING CONSTRUCTION AND PRECOMMISSIONING
MERV 13 FILTERS AFTER COMMISSIONING
Ceiling Suspended Type AHU's
Double Skin Ceiling Suspended AHU with 6 Row cooling
coils (copper tubes with aluminium fins construction),
filters sections, medium pressure fan section with
centrifugal fan/s, sq.cage induction motor belt drive, belt
guard, vibration isolators, double canvas connections and
with unit mounted emergency off station internally factory
wired between motors and emergency off station as per
specifications.

AHU Specifications:
Cooling Capacity

: 10.0 TR

Dehumidified air quantity

: 4800 CFM

Cooling Capacity

: 7.5 TR

Dehumidified air quantity

: 4550 CFM

Some other Specifications: (Common for all AHUs)


Design apparatus dew point - 12 Deg C
Chilled water entry temperature - 7 Deg C
Chilled water leaving temperature - 12 Deg C
Chilled water Flow - 2.4 GPM per TR
Filter Section
MERV 8 FILTERS DURING CONSTRUCTION AND PRECOMMISSIONING
MERV 13 FILTERS AFTER COMMISSIONING

Supply & Installation of Stater Panel with VFD as detailed


in the technical specification. Cost of Panel with Starter
with VFD should be considered by AHU Manafacturer and
it should be noted that Starter panel should be housed on
the external surface of AHU and TFA. The Communication
card to transfer the entire data available on VFD to the
BMS System. VFD shall be Danfoss VLT 6000 Series /
ABB ACH 550

15 kW

Nos

11 kW

Nos

7.5 kW

Nos

5.5 kW

Nos

FAN COIL UNITS

Amount in Rs.
In words

S.No.

Description

Qty

Unit

Rate
In Figure

Supplying, installing, testing and commissioning of


Vertical or Horizontal version powder coated fan coil
units, draw through type, each complete with necessary
rows deep chilled water coils, one or more centrifugal
fans, tropicalised motors with self lubricating bearings
aluminium / synthetic cleanable filters, primary and
secondary condensate drain pans duly with nitrile rubber
insulated, (to eliminate the eventuality of choked fan coil
unit drains)casing, coil piping connections through copper
pipes, condensate drain connection, multi core copper
power wiring, control wiring, in conduit up to the
thermostat boxes & MS boxes for thermostat inclusive of 3
way control valve (Siemens or equivalent make),
Thermostat with cooling and 3-speed motor. The spring
ruturn type control valve bypasses the chilled water when
the unit is not in operation to avoid condensation.

Cooling Capacity: 4TR, Air Quantity: 1600cfm

Nos

Cooling Capacity: 3TR, Air Quantity: 1200cfm

Nos

Cooling Capacity: 2TR, Air Quantity: 800cfm

Nos

TREATED FRESH AIR UNIT WITH HEAT RECOVERY


WHEELS
Supply,installation, testing and commissioning of
Centralised Treated Fresh air unit consists of exhaust air
block and fresh air block. Each block is made up of
double skin construction designed on modular concept
basis and has for fans, motors, VFDs for fan motors,
chilled water coil, damper and filter. Each block
module shall be fitted with other block, housing heat
recovery devices, washable metallic viscous filters (50mm
thick) and inlet and outlet dampers (extruded aluminium
low leakage construction) with bird screen for supply and
return air.
Air flow parameters: Heat Recovery wheel to recover
energy complete with desiccant coated aluminium media
rotor seal GI structural frame work to house rotor, drive
system, rotor drive motor, belt, pre-filter complete with
starter panel. The TFA shall have Thermal Break Profile.
The price quoted for Treated fresh air unit shall include
the following
a) All internal wiring, power cabling copper earthing of
treated fresh air unit motors, from the panel and control
wiring
b) Bimetallic lugs shall be used at copper to aluminium
jCoil
i t sizedshall be eightifirowti coil selected for a maximum
face velocity of 2.75 mps and external static pressure shall
be minimum 500pa.
The vendor shall be select the suitable units with minimum
leakage. The fresh air quantity required after leakage is as
follows.

Cooling Capacity: 21TR, Air Quantity: 9900cfm

Nos

Cooling Capacity: 19TR, Air Quantity: 9300cfm

Nos

Cooling Capacity: 17TR, Air Quantity: 7900cfm

Nos

Cooling Capacity: 15TR, Air Quantity: 7300cfm

Nos

Some other Specifications: (Common for all AHUs)

Amount in Rs.
In words

S.No.

Description

Qty

Unit

Rate
In Figure

Design apparatus dew point - 12 Deg C


Chilled water entry temperature - 7 Deg C
Chilled water leaving temperature - 12 Deg C
Fan Ex. static pressure
- 1.5 Inch.Wg
Filter Section
MERV 8 FILTERS DURING CONSTRUCTION AND PRECOMMISSIONING
MERV 13 FILTERS AFTER COMMISSIONING

Supply & Installation of Stater Panel with VFD as detailed


in the technical specification. Cost of Panel with Starter
with VFD should be considered by AHU Manafacturer and
it should be noted that Starter panel should be housed on
the external surface of AHU and TFA. The Communication
card to transfer the entire data available on VFD to the
BMS System. VFD shall be Danfoss VLT 6000 Series /
ABB ACH 550

7.5 kW

Nos

5.5 kW

Nos

Supply, installation, testing and commissioning Digital


Inverter - Wall mounted split Unit Capacity of 2.0TR. The
Indoor unit shall comprise of Blowers, Cooling coil, Filter
and Expansion device and drain pan. The Outdoor unit
shall comprise of digital Inverter Compressor, Air cooled
condenser & Condenser fans. Rate inclusive of required
length copper piping with 13mm thick nitrile rubber
insulation, voltage, stabilizer, refrigerant charging, power
cable from the panel/isolator, control cable, wireless
remote controller, supports for indoor and outdoor units,
etc.

Nos

PIPES AND VALVES

Supply, erection, testing and commissioning of chilled


water / Condenser water pipes. Pipes will be of MS Class
C up to 150mm dia as per IS 1239, 6 mm thick for 200mm
and 250mm dia pipes and 8mm thick above 300mm dia as
per IS 3589. Necessary RCC pedestals of required sizes
shall be provided at every 2200mm interval to run the
piping above the floor level by ACMV contractor. Rate
shall inclusive of necessary fittings like bends, elbows,
Tee, etc

All other pipe supports will have to be on regular pipe


hangers with spring and acceptable isolation in each
support. The quoted piping rate shall include for
incorporating service flanges on all valves, strainers,
service screen/basket strainer on the water line entry to all
equipments like chilled water coils and chillers service
flanges, descaling Tees, airvent valves, drain valves etc.,
required to make the circuits fully operational. The
temporary service strainers shall be removed and
discarded after the first few hours of trial runs.

250 NB - 6mm thick

Rmt

87

200 NB - 6mm thick

Rmt

667

150 NB - MS Class C

Rmt

30

125 NB - MS Class C

Rmt

151

Amount in Rs.
In words

S.No.

Description

Qty

Unit

Rate
In Figure

100 NB - MS Class C

Rmt

57

80 NB - MS Class C

Rmt

100

65 NB - MS Class C

Rmt

169

50 NB - MS Class C

Rmt

187

40 NB - MS Class C

Rmt

42

32 NB - MS Class C

Rmt

60

25 NB - MS Class C

Rmt

62

Providing and fixing in position the following GI Class B


pipe cut to required length and installed with all screw
joints, reducer, necessary elbows and tees, supporting
arrangements, etc.

50 NB

Rmt

123

32 NB

Rmt

63

25 NB

Rmt

70

Supply and erction of Thermal insulation of chilled water


piping with closed cell nitrile rubber insulation. Insulation
thickness shall be 25mm for pipes upto 65mm dia and
32mm insulation for pipes above 65mm dia

200 NB

Rmt

39

150 NB

Rmt

30

125 NB

Rmt

151

100 NB

Rmt

57

80 NB

Rmt

100

65 NB

Rmt

158

50 NB

Rmt

178

40 NB

Rmt

42

Amount in Rs.
In words

S.No.

Description

Qty

Unit

Rate
In Figure

32 NB

Rmt

49

25 NB

Rmt

63

Supply and erction of Thermal insulation of chilled water


piping with TF quality of density 24 Kg/Cu.Mtr. EPS with
GI wire and covered with polyethylene sheet as vapour
barrier. Two coats (each 6 mm thick) of cement plaster
shall be applied over chicken wire mesh lath as per the
specifications

Rmt

623

200 NB

Supply, installation, testing and commissioning of flexible


connections of suitable pressure rating to be installed at
pump suction, discharge and at pipes crossing building
expansion joints.

200 NB

Nos.

18

150 NB

Nos.

12

80 NB

Nos.

65NB

Nos.

16

50NB

Nos.

12

40NB

Nos.

32NB

Nos.

25NB

Nos.

Providing and fixing in position the following Butterfly


valves (PN16) complete with end flanges/matching
flanges, additional supports, fixing accessories, thermal
insulation etc. as per specification.

200 NB - Gear driven

Nos.

18

150 NB - Lever operated

Nos.

12

125 NB - Lever operated

Nos.

Amount in Rs.
In words

S.No.

Description

Qty

Unit

Rate
In Figure

80 NB - Lever operated

Nos.

65 NB - Lever operated

Nos.

19

50 NB - Lever operated

Nos.

20

Providing and fixing in position the following Ball valves


complete with end flanges/matching flanges, additional
supports, fixing accessories etc. as per specification.

40 NB - Lever operated

Nos.

32 NB - Lever operated

Nos.

25 NB - Lever operated

Nos.

21

Supply and erection of Double plate Check valves with


cast iron body Gr 220 ASTM A217 Gr-CA15, plate SS316
springs, SS410 hinges/Stop pin and AISI SS316 bearings,
matching flanges / Buna or rubber seal to ANSI 125 seal,
thermal insulation etc.

200 NB

Nos.

150 NB

Nos.

50 NB

Nos.

Supply and erection of Intelligent balancing valves, nonrising spindle of stainless steel SS410 stem, stainless
steel disc of AISI SS410 with EPDM sealing on seat,
double seal by EPDM back flow and graphic asbestos
packing on spindle C1220 cast iron / aluminium / MS
fabricated hand wheel with pressure test cocks for
measurements and regulation of flow through pressure
drop across the valves, thermal insulation as specified,
flanges boards, drain valves etc.
suitable
for
computerized balancing instrumentation probes.

200 NB

Nos.

150 NB

Nos

125 NB

Nos

Amount in Rs.
In words

S.No.

Description

Qty

Unit

Rate
In Figure

80 NB

Nos

65 NB

Nos

50 NB

Nos

40 NB

Nos

32 NB

Nos

10

Supply and erection of MS fabricated Y type strainer


with removable brass / stainless steel (SS-316) screen
(24G) with 3mm perforation and permanent magnet, drain
piping(SS-410) complete with matching flanges and
thermal insulation as specified

80 NB

Nos.

65 NB

Nos.

50 NB

Nos.

40 NB

Nos.

32 NB

Nos

11

Supply and erection of Ball Valve with Strainer. Valve


shall be bronze forged body construction with chrome
plated bronze ball and handle of stainless steel
constructions complete with matching flanges and thermal
insulation as specified

32 NB

Nos.

25 NB

Nos.

12

Supply,installation, testing and commissioning of Two way


motorised Valves (ON/OFF Type) provided with spring
return function in chilled water lines at chillers and
condenser water line at cooling towers. The actuator of the
motorized valve shall have required torque to ON/Off the
actuator with 220 V / 24 V transformer duly encased and
wired. The motorised valve & actuator shall be compatible
to third party intergration and necessarry communication
cables, hardware, convertor, etc shall be included. The
valves shall be suitable for following pipe sizes

Amount in Rs.
In words

S.No.

Description

Qty

Unit

Rate
In Figure

200 NB

Nos.

150 NB

Nos.

13

Supply,installation, testing and commissioning of Two way


motorised Valves (Modulating Type) provided with spring
return function in chilled water lines at AHUs. The actuator
of the motorized valve shall have required torque to
ON/Off and modudate the actuator with 220 V / 24 V
transformer duly encased and wired. The motorised valve
& actuator shall be compatible to third party intergration
and necessarry communication cables, hardware,
convertor, etc shall be included. The valves shall be
suitable for following pipe sizes

150 NB

Nos.

80 NB

Nos.

65 NB

Nos.

50 NB

Nos.

40 NB

Nos.

32 NB

Nos.

14

Supply, installation, testing & commissioning of Closed


expansion tank as per standards & requirements.
Capacity 1000 Ltrs. Tank shall be complete with 0.5 HP
Pumps required in the configuration of 1 working + 1
Stand By. The cost shall include necessary valve package
& control logic panel for pump automation

Sets

15

Supply and erection of Water Dial Type Pressure gauges


complete with ball valve, gauge valve mounting, fittings
and copper tubing extension where required

Nos.

66

Nos.

52

Nos

16

17

Supply and erection of Dial Type Thermometers with


copper separable well complete with guard mounted on
water lines, thermo wells, etc., in the inlet and outlet of
cooling coil connections.
Supply and erection of probe type flow meter to measure
the flow in CHW pipe line. The flow meter shall be
provided with necessary fittings & electronic digital read
out.

18

Supply and erection of Temperature sensors with


necessary fittings & electronic digital read out.

Nos

19

Supply and erection of Automatic Air Vents shall be


installed at all high sections of piping. The discharge from
this air vents shall be piped via tubes of appropriate size
to the nearest waste drain pipe.

Nos.

33

AIR DISTRIBUTION SYSTEM

Amount in Rs.
In words

S.No.

Description

Qty

Unit

Rate
In Figure

Supply, installation, testing and balancing of Air


Distribution System consists of factory fabricated sheet
metal ducting complete with supports (anchor fastners and
tie-rods, cradles, angle iron supports, GI bolts and nuts,
4mm thick self-adhesive neoprene rubber gasket,
stiffeners, zinc chromate painted angle iron flanges,
chipping and plastering of openings made for duct
supports etc., filling the gap with fibre glass wool and with
fire sealant complete as per specification. The rates
quoted shall include turning vanes, straightening vanes,
splitters, inspection doors probe, inlets with test openings
enclosures complete with locking caps, chain, gaskets,
insulating plugs, and extension for insulated ductwork etc.

1.2mm thick GSS (18G) ducting factory fabricated

Sq.m.

182

1.0mm thick GSS ducting (20G) factory fabricated

Sq.m.

102

0.8mm thick GSS ducting (22G) factory fabricated

Sq.m.

2028

0.63mm thick GSS ducting (24G) factory fabricated

Sq.m.

4775

Supply and installing of Accoustic insulation, Material


shall be processed Nitrile Rubber foam with MICROBAN
having anti-microbial protection. The material should be
fibre free. The density of the same shall be within 140-180
Kg/m3.The material should have a thermal conductivity
not exceeding 0.038 W/mK. The maximum surface
temperature the material should withstand is 105 C and
minimum temperature should be -20C. The Thickness of
the material shall be 15mm. The material should conform
to Class 1 rating for surface spread of Flame as per BS
476 Part 7.

Sq.m.

1318

Supply and erection of Thermal Insulation of Supply air


duct with 9mm thick closed cell nitrile rubber temperature
range from -10C to +60C, Class O fire category and as
per specification.

Sq.m.

4521

Supply and installation of AHU room acoustic lining on


walls/mechanical plant room with 50 mm thick fibre glass
and 48 Kg/Cum density with GI frame grid and covered
with 22G perforated GI sheet as per the approved shop
drawings & specifications.

Sqm

1282

Flexible duct connections between main duct and diffuser


plenums shall be 25mm thick fiber glass pre-insulated,
single ply / multiply Aluminium construction and with
multiple layers of polyester film glass fiber covered with
mechanical lock sheets/ Aluminium laminated jackets-Fire
resistant complete with Pre-fabricated and powder coated
Aluminium angle frame mounting brackets and supports
and clamping for the both ends

300mm dia

Rmt

66

250mm dia

Rmt

432

Supply and fixing of Spigot damper shall be installed


from take off collar to diffuser plelum boxes and at plenum
boxes (low leakage) made out of 1.6mm galvanized sheet
steel frame and blades of 1.0mm galvanized steel with
suitable links.

Amount in Rs.
In words

S.No.

Description

Qty

Unit

Rate
In Figure

300mm dia

Nos.

44

250mm dia

Nos.

288

Supply and fixing of Extruded Aluminium, powder coated


Supply air diffusers with removable centre core overall
size 600 x 600mm without volume control dampers. The
rate shall inclusive of Pre-fabricated Acoustic insulated
plenum boxes for supply air diffusers with 12mm thick
open cell nitrile rubber lining inside the plenum box. The
plenum box shall be supported at the four corners with
hanger / chain support.

375 x 375mm neck size

Nos

44

300 x 300mm neck size

Nos

288

Supply and fixing of Extruded Aluminium, powder Coated


return air diffusers with removable centre core overall
size 600 x 600mm without volume control dampers.

Nos

350

Supply and installation of Powder coated extruded


aluminium continuous linear 2 way grilles with 15 degree
deflection with jet nozzles and volume control damper for
supply air for auditorium as per drawing & specifications

Sq.m.

10

Supply and installation of Powder coated extruded


aluminium continuous linear 2 way grilles with 15 degree
deflection with volume control damper for supply air as
per specifications

Sq.m.

19

11

Supply and installation of Powder coated extruded


aluminium continuous linear grilles with 0 degree
deflection without volume control damper for return air as
per specifications.

Sq.m.

35

12

Supply and installation of Powder coated extruded


aluminium Circular diffuder with jet nozzles and volume
control damper for supply air as per specifications. Dia
600mm

Nos

40

13

Supply and installation of Powder coated extruded


aluminium Circular Diffusers without volume control
damper for return air as per specifications. Dia 300mm

Nos

10

14

Supply, installation, testing and balancing of GI louver


volume control damper (low leakage) made out of
1.6mm thick galvanised sheet steel frame and blades of
1.6mm galvanised steel with suitable links, handles, levers
and quadrants for manual control of volume of air flow and
for proper balancing of air distribution system.

Sq.m.

36

Amount in Rs.
In words

S.No.

Description

Qty

Unit

Rate
In Figure

15

Supply, installation, testing and commissioning of


motorised damper complete with control panel, actuator,
CO2 sensors and transmitters, control / communication
cables, etc for Demand Control Ventilation System. The
control panel shall be suitable for BMS intergration

Motorised Dampers.

Control Panel & Wiring (including actuators).

16

Supply, installation, testing and commissioning of


motorised combined smoke & fire damper complete with
control panel, actuator, sensors and transmitters, control /
communication cables, etc. The power for actuator shall
be derived from the AHU starter panel.

Smoke & Fire Dampers.

Control Panel & Wiring (including actuators).

17

Sq.m.

Nos

28

Sq.m.

57

Nos

107

Supply and installation of Powder coated extruded


aluminium grilles with 0 degree deflection with volume
control damper for exhaust air as per specifications

Sq.m.

18

Supply and installation of Powder coated extruded


aluminium air transfer door grilles comprising of front
section with inverted V horizontal blades, borders,
countersunk for screw fixing, and matching rear side frame
flanges of 500x300 sizes.

Nos

60

19

Supply and installation of Aluminium powder coated fresh


air intake / outlet grille complete with volume control
damper, vermin netting and 45 deg angle suitable for
protection against splashing rain water fixed in a powder
coated Aluminium angle mount frames.

Sq.m.

22

20

Supply, installation, testing and commissioning of 1.5m


length sound attenuators as per specifications

Sq.m.

21

Supply, installation, testing and commissioning of cross


talk attenuators at return air path as per specifications

Sq.m.

24

VENTILATION SYSTEM

Supply, installation, testing and commissioning of


Ventilation fans consists of GSS rectangular cabinet,
centrifugal blower with backward/forward curved blades,
fan motor, removable access door for easy accessibility to
motor and fan, flanged inlet and outlet for easy duct work
connection, thermally protected motor and necessary
supports. Motors shall be suitable for 3 Phase or 1 Phase
AC supply, fan efficiency greater than 75% and the
capacity are as follows. (Weather proof for outdoor type
fans and no weather proof for indoor type fans)

Nos.

Air flow rate : 5400CFM (Toilet exhaust) - Outdoor type


a

Ex. Static Pressure


rating:2.20kW

30

mmWG,

Max

Power

Air flow rate : 3100CFM (Toilet exhaust) - Outdoor type

Amount in Rs.
In words

S.No.

Description

Qty

Unit

Rate
In Figure

Ex. Static Pressure


rating:1.10kW

30

mmWG,

Max

Power

Nos.

Nos.

Nos.

Nos

Nos

Nos

Nos.

Nos.

Nos.

Nos.

Nos.

Nos.

Nos.

Nos.

Air flow rate : 2920 CFM (Toilet exhaust) - Outdoor type


c

Ex. Static Pressure


rating:1.10kW

30

mmWG,

Max

Power

Air flow rate : 650 CFM (Smokeroom exhaust) - Outdoor


type
d

Ex. Static Pressure


rating:0.30kW

25

mmWG,

Max

Power

Air flow rate : 400 CFM (Toilet exhaust) - Outdoor type


e

Ex. Static Pressure


rating:0.30kW

30

mmWG,

Max

Power

Air flow rate : 200 CFM (Toilet exhaust) - Outdoor type


f
Ex. Static Pressure
rating:0.10kW

30

mmWG,

Max

Power

Air flow rate : 1550 CFM (Electrical Room exhaust) Outdoor type
g
Ex. Static Pressure
rating:0.60kW

25

mmWG,

Max

Power

Air flow rate : 2100 CFM (Electrical Room exhaust) Outdoor type
h
Ex. Static Pressure
rating:0.75kW

25

mmWG,

Max

Power

Air flow rate : 7200 CFM (Staircase presurrisation) - Dual


speed - Outdoor type
i
Ex. Static Pressure : 30 mmWG, Max Power rating:4.0kW
Air flow rate : 6900 CFM (Staircase presurrisation) - Dual
speed - Outdoor type
j
Ex. Static Pressure : 30 mmWG, Max Power rating:4.0kW
Air flow rate : 6600 CFM (Staircase presurrisation) - Dual
speed - Outdoor type
k
Ex. Static Pressure : 30 mmWG, Max Power rating:4.0kW
Air flow rate : 8000 CFM (Liftwell presurrisation) - Outdoor
type
l
Ex. Static Pressure : 30 mmWG, Max Power rating:4.0kW
Air flow rate : 7500 CFM (Liftwell presurrisation) - Outdoor
type
m
Ex. Static Pressure : 30 mmWG, Max Power rating:4.0kW
Air flow rate : 2050 CFM (Kitchen - Fresh air) - Outdoor
type
n
Ex. Static Pressure : 30 mmWG, Max Power rating:1.0kW
Air flow rate : 2350 CFM (Kitchen - Exhaust) - Outdoor
type
o
Ex. Static Pressure
rating:1.30kW

40

mmWG,

Max

Power

Amount in Rs.
In words

S.No.

Description

Qty

Unit

Rate
In Figure

Supply, installation, testing and commissioning of Direct


Driven smokespill Tube/Vane Axial fans with inlet & outlet
protection net. Fan shall be AMCA certified for Air &
Sound performance, balanced to vibration grade of G2.5
as per AMCA 204. Fan shall be complete with GSS casing
( 220 GSM ), Aluminium impeller, Motor Class H, special
rated motor certified for 250 Deg C for 2 Hrs 415/3P/50Hz. Complete assembly shall be certified for
250 Deg C for 2 Hrs. fire rating as per BS 7346 Part 2:
1990 Class B or EN 12101-3 & the copy of the Fire-test
report has to be submitted for the approval. These fans
shall run during Normal as well as fire mode. Max motor
rating: 18.5 kW

Air Flow: 57,000 cfm & Static pressure: 25mm WG.

Nos.

Supply, installation, testing and commissioning of Induced


Air Axial Jet fans. Fan shall be AMCA certified for Air &
Sound performance, balanced to vibration grade of G2.5
as per AMCA 204. Fan shall be complete with GSS casing
(220 GSM ), Aluminium impeller, Motor Class H, special
rated motor certified for 250 Deg C for 2 Hrs 415/3P/50Hz, inlet & outlet protection net. Complete
assembly shall be certified for 250 Deg C for 2 Hrs. fire
rating as per BS 7346 Part 2: 1990 Class B or EN 12101-3
& the copy of the Fire-test report has to be submitted for
the approval. The Locationing of the jet fans has to be
done in such a way that the Air velocity at any point on the
plane of 1m from the ground level should not be less than
0.25m/s during the normal mode. Each fan shall be
complete with Dual speed motor.

Nos.

18

Supply, installation, testing and commissioning of


Electrical cum PLC panel with feeders and suitable DOL
starters for Axial Fans and Jet fans of 0.11 / 0.75 kW dual
speed motor built in logic controller. The panel shall cater
all axail fans and Jet fans controlled by CO sensor. The
panel shall be with switch gears, suitable incomer MCCB,
Bus bar, PLC and necessary control wiring and indicators,
suitable starters, etc to successful operation. The rate
shall be inclusive of necessary hardware and software for
integrating the Electrical cum PLC panel / Jet fans / Main
Exhaust fans / CO sensors / etc. All the equipment shall
be IBMS compatible and required provision shall be made
by the ACMV contractor.

Lot

Computing and submitting the CFD analysis for the


basement leading to the selection & location of the fans.

Lot

Nos.

Nos.

H
1

Supply, installation, testing and commissioning of CO


sensor located at basement for maintaining air quality
using jet fans. The sensor shall be microprocessor based
and shall incorporate suitable measurement techniques to
be capable of generating an output signal proportional to
level of contamination by cabron Monoxide and other
athmospheric pollutants.
Supply and fixing of Acoustic Silncers for exhaust fans
inlets with 1000 mm long, with 50mm thick 32kg/m3
density fibre glass, 2 layers of RP tissue, 22G perforated
aluminium cover sheet, Fixing bolts, supporting
arrangements,etc.
Supply, installation, testing & commissioning and
handing over of the following:
VARIABLE AIR VOLUME BOXES (Damper Actuator Type
based on temperature)

Amount in Rs.
In words

S.No.

Description

Qty

Unit

Rate
In Figure

Supplying, installing, testing and commissioning of


Pressure Dependent Type Variable Air voulme Terminal
units, suitable for installtion in horizontal ducts. The casing
shall be double skin acoustically lined and constructed
with galvanised sheet steel. Vendor should include all
accessories such as single / multi leaf damper (with
equal% characteristics), actuators, control cabling ,
thermostat, temperature sensor, pressure sensor, power
cabling from nearest socket and feedback control cabling
upto VFD panel / DDC panel in AHU room and any other
ancilary requirement for the functioning of the units. The
rate shall inclusive of BCU / Hardware & Software for
BMS integration to tansfer minimum 4 points from each
VAV Box as listed in the Specification
The minimum air flow is zero and the maximum air flow
(cfm) as follows

500 cfm

Nos.

750 cfm

Nos.

1000 cfm

Nos.

15

1250 cfm

Nos.

1500 cfm

Nos.

1750 cfm

Nos.

2000 cfm

Nos.

2250 cfm

Nos.

2500 cfm

No.

2750 cfm

Nos.

4000 cfm

No.

4500 cfm

Nos.

Amount in Rs.
In words

S.No.

Description

Qty

Unit

Rate
In Figure

5000 cfm

No.

6000 cfm

Nos.

7000 cfm

Nos.

7500 cfm

Nos.

ACMV RELATED ELECTRICAL ITEMS

Supply, fabrication, testing and commissioning of 400A


TP+N isolator suitable for termination of chiller power
cable. The inlet cable shall be 1 runs of 3.5 Core 240
Sq.mm XLPE Aluminium armoured Cable and the outlet
shall be 1 runs of 3.5 Core 240 Sq.mm XLPE copper
armoured Cable with all necessary controls and
accessories

Sets

PUMP PANEL

Nos

Design, supply, fixing, testing and commissioning of


cubicle type floor mounting switch board comprising of the
following, the board shall be fabricated as per the detailed
specification enclosed. (Pump Panel)
INCOMING
400A TPN MCCB 35 KA with connected accessories
1No.as incomer
OUTGOINGS
100A TPN MCCB, 16 KA 8Nos
63A TPN MCCB, 16 KA 4Nos
With necessary copper busbars, interconnections,
providing Digital type voltmeter, ammeter with selector
switches, ON,OFF,TRIP, phase indication lamp, Fuse,
Switch control etc.and also refer the drawing.
The incoming and outgoing breakers shall be
Microprocessor based release such as overload,short
circuit,earth fault,neutral protection,etc.
400A Amps TPN copper busbars : All the neutral
busbars shall have half the capacity of phase busbars
(1.2A/Sq. mm.).

Supply erection testing and commissioning of the


following starter panel with Ammeter, selector switch,
suitable ratio of CTs,control fuses, Auto/Manual selector
switch, on/off/trip indication lamp with necessary power
and control wiring interconnections etc.,with suitable
provision to link with IBMS for remote operation and all
connected necessary accessories in a suitable MS
enclosure with painting , earthling and suitable fixing
arrangement as required.

1No. 100A TP&N MCCB with adjustable variable settings


16 KA with all connected accessories. 1 No. Star Delta
starter (3 Phase) suitable for 17 KW for condenser
water pump

Nos

1No. 63A TP&N MCCB with adjustable variable settings


16 KA with all connected accessories. 1 No. Star Delta
starter starter (3 Phase) suitable for 11 KW for cooling
tower

Nos

1No. 32A TP&N MCB with adjustable variable settings 16


KA with all connected accessories. 1 No. DOL starter (3
Phase) suitable for 3.7 KW for ceiling suspended
AHUs

Nos

Amount in Rs.
In words

S.No.

Description

Qty

Unit

Rate
In Figure

1No. 63A TP&N MCCB with adjustable variable settings


16 KA with all connected accessories. 1 No. Star Delta
starter (3 Phase) suitable for 18.5 KW for Basement
exhaust fan

Nos

1No. 16/20A TP&N MCB with adjustable variable settings


10 KA with all connected accessories. 1 No. DOL starter
(3 Phase) suitable for 1.1 KW for Dual Speed Jet fans

Nos

18

1No. 32A TP&N MCB with adjustable variable settings 16


KA with all connected accessories. 1 No. DOL starter (3
Phase) suitable for 4.0 KW for Staircase/ Liftwell
pressurisation fans (Dual speed)

Nos

1No. 16/20A TP&N MCB with adjustable variable settings


10 KA with all connected accessories. 1 No. DOL starter
(3 Phase) suitable for upto 2.5 KW for exhaust fans

Nos

Supply & installation of 16/20A DP MCB with Suitable


enclosure box for 1 phase ventilation fan

Nos

Supply & installation of 6/16A SP MCB with Plug Top and


Base Box and other associated accessories as required

Nos

95

Supply and fixing of lockable type push button control for


ON / OFF

Nos

66

CABLES AND TERMINATION

Supply, Laying, Testing and Commissioning of the


following size PVC insulated and PVC sheathed / XLPE
Power cable of 1.1KV grade Aluminium / Copper
conductor armoured / unarmoured cables. Cables shall
be laying on the cable tray and partially laid on
wall/ceiling with suitable clamps & necessary fixing
accessoriesetc.asrequired.

3.5 Core 240 Sqmm XLPE Arm. Cu.cable

Rmt

30

3.5 Core 50 Sqmm XLPE Arm. AL.cable

Rmt

90

4 Core 25 Sqmm XLPE Arm. AL.cable

Rmt

115

4 Core 16 Sqmm XLPE Arm. AL.cable

Rmt

240

4 Core 4 Sqmm XLPE Arm. Cu.cable

Rmt

500

4C 2.5 Sqmm XLPE Arm. Cu. Cable

Rmt

40

3C 2.5 Sqmm XLPE Arm. Cu. Cable

Rmt

90

3C 1.5 Sqmm XLPE Arm. Cu. Cable

Rmt

715

Amount in Rs.
In words

S.No.

Description

Qty

Unit

Rate
In Figure

Supply, termination and commissioning of the following


size cables with suitable double compression glands and
crimping socket with suitable earth clip & fixing
accessories.

3.5 Core 240 Sqmm XLPE Arm. Cu.cable

Nos

3.5 Core 50 Sqmm XLPE Arm. AL.cable

Nos

24

4 Core 25 Sqmm XLPE Arm. AL.cable

Nos

14

4 Core 16 Sqmm XLPE Arm. AL.cable

Nos

48

4 Core 4 Sqmm XLPE Arm. Cu.cable

Nos

50

4C 2.5 Sqmm XLPE Arm. Cu. Cable

Nos

12

3C 2.5 Sqmm PVC Arm. Cu. Cable

Nos

14

3C 1.5 Sqmm PVC Arm. Cu. Cable

Nos

190

EARTHING

Supply and laying of 8 gauge bare copper conductor for


equipments earthing.

Rmt

210

Supply and laying of 10 gauge bare copper conductor for


equipments earthing.

Rmt

150

10

Supply and laying of 25x3mm bare copper strip for


equipments earthing.

Rmt

120

11

Cable Trays / Accessories and Supports


Supply and Installation of the following Cable Trays /
Accessories

Prefabricated hot dip galvanised 2.5mm thick sheet


perforated / Ladder type cable tray including all
necessary curved bendsteesreducers, coupler plates,
fastners etc.,for the following sizes. Inclusive necessary
fixingarrangementetc.
a

300mm Wide Ladder

Rmt

20

150mm Wide Ladder

Rmt

20

300mm Wide Tray Perforated

Rmt

40

Amount in Rs.
In words

S.No.

Description

Qty

Unit

Rate
In Figure

12

150mm Wide Tray Perforated

Rmt

50

Supply and Installation of MS flat / angle iron supports


for various purpose if required with various sizes
including cutting,welding,grinding,fixing accessories and
one coat of primer & two coats of enamel paints, minor
civil works etc. as required.(Note: The flat / angle iron
weight will be arrived on the basis of theoretical
calculationonly).

MT

0.5

TOTAL AMOUNT OF HVAC WORKS

IBMS WORKS

A-I

Supply, intallation, testing and


Commissioning of the following system as
per the technical specification.
FIRE ALARM SYSTEM.
Analogue addressable micro Process controlled Fire Alarm Control Panels, capable of
being IP networked to the central monitoring
System, to monitor and integrated the following
quantity
of
accossries
like
detectors,
MCP's/hooters/control modules, Fault Isolation
Modules, hooters, response indicators, fire/fault
indicators,
audio-visual
signals,
central
processing units, complete with LCD display,
zone indicating LEDs as per the detailed
specification: complete with Battery backup with
charger for each panel. Each loop should
provided with minimum 125 detectors /devices
8 LOOP PANEL expendable to 12 Loop .

Set

Set

140

Nos.

600

Nos.

1 LOOP PANEL-Substation expendable to 4


b
loop
Note: Providing Windows based graphical
software, (with necessary software addresses
required as per BOQ) on MS windows 2000/XP
or latest platform,including Alarm Management

for IBMS as per the above item


RATE OF RISE HEAT DETECTORS :
Supply, Installation, Testing and Commissioning
of Rate of Rise Heat Detectors (Thermal
Detectors):GRADE-I Addressable analogue type
Heat Detectors with solid state design with
sensing element combination of fixed type and
rate of rise of temperature indicating LED, with
inbuilt isolator or isolator in basecomplete with
base etc. as per detailed specifications.

SMOKE DETECTORS
Addressable analogue

MUTISENSOR

type

smoke detectors with dual scattering with


thermal sensing, solid state design, indicating
3

LED,with inbuilt isolator or isolator in base with


mounting base etc. as per detailed specification.
The rate shall inclusive of necessary base box,
connecting glad for above detectors

Amount in Rs.
In words

S.No.

Description

Qty

Unit

Rate
In Figure

Duct detector suitable for providing the return air


path with suitable fixing accessories

20

Nos.

ELECTRONIC HOOTERS :
Hooter with relay module and storb light with
minimum 85 db audiable and control relay
module, power supply units etc

90

Nos.

45

Nos.

50

Nos.

25

Nos.

280

Nos.

Nos.

MANUAL CALL POINTS :


Manual call points pull stations of approved
make with NO/NC contacts slim type and
projecting out from the surface of enclosurewith
glass suitable for addressable function with
inbuilt isolator.
CONTROL MODULE
Addressable control module to trip the AHU,s,
Access door, triggering the DVR.lift landing etc
Addressable monitor module along with door
contact for Fire doors

10

11

12

RESPONSE INDICATOR
Response indicator for mounting on false ceiling
at the entries of the cabin for indicating the
operation for detectors in the above areas.

LPG GAS DETECTOR


Supply, fixing, testing and commissioning of
LPG gas detection system for Canteen area

CABLES / WIRES
Supply and fixing of 2C 1.5 armoured copper
FRLS cable in celing with suitable clamps and
14000
screws (RED colour)
25mm dia GI conduit for laying of fire cable
including necessary accessories like bend,
junction box fixing of clamps etc., complete.
The conduit shall be recessed in wall including
chipping, roup plastering etc. (only for the
Drops - MCPs)

Mtrs

300

Mtrs

15

Set

BEAM DETECTOR
Supply, fixing, testing and commissioning of
Wall mounted type Beam detector with receiver
coverage of minimum 25 mtr distance as per
13

detailed specifications. The adjustable angle


shall be +/- 10o for both vertical and Horizontal.
The detector should be capable of connecting to
existing Addressable fire alarm panel.

A-II

Total of A-I C/o to summary


PUBLIC ADDRESS SYSTEM AND
SYSTEM
Supply, intallation, testing and

EVC

Commissioning of the following system as


per the technical specification.

Amount in Rs.
In words

S.No.

Description

Qty

Unit

Rate
In Figure

14

Supply, Installation, Testing and Commssioining


of System Controller complete with 16 Zone Call
Station, Stem Type Microphone, 2 mm thick
CRCA Sheet Powder Coated Rack, Dual Tone
Control for Speech & Music, integration facility
with Fire Alarm System, tone generator &
Speech Processor with relays for activating tone
& pre-recorded fire alarm messages, facility to
intregrate with the base builder P.A System as
specified in the Tender Specifications . The rate
inclusive of Periarity module, selector switch etc

Each

Each

25

Set

40

Set

210

Set

19

Supply, Installation, Testing and Commssioining


of Rack Mounted minimum 480 W Power
Amplifier as specified in
the Tender
Specifications

Set

20

Supply, Installation, Testing and Commssioining


of Rack Mounted minimum 120 W Power
Amplifier as specified in
the Tender
Specifications

Set

7500

Mtrs

No

15

16

17

18

21

22

Supply, intallation, testing and Commissioning of


19" Rack 650mm depth, 19U high amplifierrack
assembly made of aluminium channel , with side
and rear panels made of 14 swg powder coated
sheet steel front transparent persplexdoor and
with rails, rollers & bearings. Fans provided at
the top for ventilation side panels will be
ventilated type.The rack shall be powder coated
of approved color and spare 'U' shall be covered
with blank panels.
Supply, Installation, Testing and Commssioining
of 20 W Wall/Column Mounted Speakers with
line matching transformers and selectedable tap
setting
as
specified
in
the
Tender
Specifications
Supply, Installation, Testing and Commssioining
of 6 W Wall Mounted Speakers with line
matching transformers & selectedable tap
setting
as specified in the Tender
Specifications for electical rooms and AHU
rooms
Supply, Installation, Testing and Commssioining
of 6 W Ceiling Mounted Speakers with line
matching transformers & selectedable tap
setting
as specified in the Tender
Specifications for false ceiling areas.

Supply, Installation, Testing and Commssioining


of Supply & Laying of 2 core twin twisted 48/0.2
ATC, Multi strand, over all armoured speaker
cable as specified in the Tender Specifications
Supply, Installation, Testing and Commssioining
of Micro phone unit with back box, STAND
LEGNTH OF CABLES

Amount in Rs.
In words

S.No.

Description

Qty

Unit

Rate
In Figure

23

Supplying, installing, testing and commissioning


of 1 No. each of AM/FM Tuner, DVD player with
overriding facility, Music Source Selector, with
assignable priority on each channel to accept
Auto dialar for intefacing with Fire alarm system

No

No

No

Each

Nos

Nos

Nos

No

FRLS sheilded Cables:


Cable from electromagnetic lock/Sensor to
Controller - 1 Sqmm 4 C sqmm multistand
armoued shilelded cable

300

Mtrs

Cable from Reader to Controller - 1 Sqmm 6 C


sqmm multistand shielded armoured cable

300

Mtrs

Network cable for controller to controller Armoured cable

300

Mtrs

Each

10

Each

Set

24

25

A-III

16 Zone Auto speech processor (Digital Voice


Recorder) for fire activation message

ACCESS CONTROL SYSTEM


Access control system complete with
necessary hardware, Software etc., as
specified
for
centralized
securtiy
monitoring. Supply, intallation, testing and
Commissioning of the following system as
per the technical specification.
Access Controllers, each with capacity of
10000 events buffer memory connecting the the
item listed below such as card readers,
Magnetic locks, boom barriers etc

2 door - 2 reader controller


26
27

Proximity Card readers


base plate

with stainless steel

Electromagnetic Locks - Double Door


28
Magnetic Contact
29
Emergency push button (glass type)
30
31

32

33

34

Access management software with time and


attendance module suitable for flexi time report
regenration as per client requirement with SQL
/Oracle data base.
Proximity Card with holder, Lanyard, Adhsive
lables for printing the ID card
Supply and commissioning of Single Door Panic
bar with Contacts and hooterfor all Fire Doors
for monitoring door status with necessary
hardware as specified for centralized securtiy
monitoring. The local alarm panel shall have
provision for reset key with external Key switch.

Amount in Rs.
In words

S.No.

Description

Qty

Unit

Rate
In Figure

A -I V CLOSED CIRCUIT TELEVISION SYSTEM


Supply, installation, testing and
commissioning of following system:
Colour 1/3" fixed dome indoor camera , 520 TV
lines resolution and minimum lux level not more
35
than 1.2 lux (F1.2) including all mounting
supports / brackets and fixing accessories.

36

37

Color high speed 1/4" Pan/Tilt/Zoom indoor


camera, 520 TVL (PAL)lines resolution and
minimum lux level not more than 0.05 lux at
F1.2 with 23X optical or better motorized zoom
lens, receiver, driver, Pan/Tilt and necessay
mounting support / bracket, accessories as
required for indoor installation. and mounting
support as per specification.
Color high speed 1/4" Pan/Tilt/Zoom outdoor
camera, 520 TVL (PAL)lines resolution and
minimum lux level not more than 0.05 lux at
F1.2 with 23X optical or better motorized zoom
lens, receiver, driver, Pan/Tilt and necessay
mounting support / bracket, accessories as
required for outdoor installation along with
standard outdoor enclosure with suitable
accessories and mounting support as per
specification.
Power Supply Unit fixed cameras-12V

38

39

40

41

DC/AC Power supply unit as required for the


PTZ cameras-24V
16 Channel Duplex Digital Video Recorder for
multiplexing and digital recording , suitable for
live viewing and playback while recording ,
Motion detection, alarm event detection with
TCP / IP connectivity - Hard disc capacity 4TB
46" diagonal, 1920 x 1080 pixels LED television
with all mounting bracket, connection card wire,
remote control etc as per the specification.

23

Nos

Nos

Nos

23

Nos

12

Nos

Nos

Nos

5000

Mts

2500

Mts

100

Mts

Nos

Nos

4000

Mtr

Cables:
Supply and laying of RG 11Coaxial armoured
42

43

44

45

46

Cable
Supply and laying of 2 Core 1.5 Sqm Twisted
pair Shielded armmoured FRLS cable for PTZ
operation
Supply and Fixing of 25 MM GI conduit with all
necessary accessories.
6 Mtr height GI post with necessary mounting
bracket, weather proof box and Civil works for
external cameras.
Mounting bracket with accessories for external
camera mounted at terrace .
3 Core 2.5 Sq.mm copper armoured Cable

47
power

Amount in Rs.
In words

S.No.

Description

Qty

Unit

Rate
In Figure

A-V

48

49

INTERGRATED BUILDING MANAGEMENT


SYSTEM AND BUILDING MANAGEMENT
SYSTEM:
BAS SERVER
Design
supply,
installing,
testing
and
commissioning
Microprocesser
based
Intergrated Building Management System as per
the detailed specifications for complete and
satisfactory operation and control and to local
authorities approval.
Main stations and
subsystems with LAN, complete with hardware
and software to provide graphical users
interface consisting of System PC comprising
Intel core i 7 Ghz Processor , 4GB DDr2 RAM
@ 667 Mhz , 500 GB HDD , Keyboard, Optical
mouse, ATX P IV Cabinet with SMPS Prime
Source, DVD Writer, Speaker with Window
Latest operating system. The system should be
supplied with 21" TFT Color Monitor. .Service
pack XP-2 (Main server - HOT Stand by /
Parallel reduendancy mode) (1 set = 2 nos)
GRAPHICAL SOFTWARE
Providing Windows based graphical software,
(with necessary software addresses required as
per I/O list) on MS windows 2000/XP or NT
platform,including Alarm Management for IBMS
as per the above item

Set

Set

Set

Each

Each

Each

SOFT POINTS
Providing necessary Software and Hardware for
Interfacing through a gate way for monitoring
through serial Modbus interface for the data
50

points for Chillers , VFDs , VAVs, etc as per


the detailed IO summary in HVAC tender .
Total soft points

51

a
b
52

950 pts including energy

meters, UPS etc


MONITORING STATION AND PRINTERS:
Monitoring station as per technical specfication
and system PC comprising Intelcore T2 Duo 2.8
Ghz Processor @ L2 Cache 3 MB intel 31 PR
mother board, 4GB DDr2 RAM @ 667 Mhz ,
250GB HDD , Keyboard, Optical mouse,external
speakers, sound card ATX P IV Cabinet with
SMPS Prime Source,DVD Writer,Service pack
XP-2 with Window
NT/2000 operating
system.The system should be supplied with 21"
TFT Color Monitor.1. FIRE & BMS PC
2. CCTV & ACCESS PC

Supply and commissioning of 600 DPI Colour


Inkjet Printer
Supply and commissioning of Single A4 size
Laser Printer
DIRECT DIGITAL CONTROLLER:

Amount in Rs.
In words

S.No.

Description

Qty

Unit

Rate
In Figure

Supply, installation, testing and commissioning


of Autonomous networkable DDC Controller
with 32 bit microprocessor based standalone
and networkable type with real time clock and
historical database of min 1 Mb with panels,
peer to peer communicable DDC modules, input
or output relays, terminal block, real time clock,
networking and inbuilt data buffer for Following

requirement as per Enclosed IO summary .


DDC-TYPE A (Chiller+VFD Pump+Condensor
Pump+ Fan)

Set

Set

Set

Set

Set

Set

Set

Set

Nos.

Nos

Nos

DDC-TYPE B (1 AHU+1 TFA)


b
DDC-TYPE C (2 AHU + 2 CSU/FCU)
c
DDC-TYPE D (1 lift well pres. + 1 No. stair. Prs.)
d
DDC-TYPE E (Electrical panel at substation)
e
DDC-TYPE F (Lift panel)
f
DDC-TYPE G (UPS)
g
DDC-TYPE H (Basement Exhaust & jet Fan)
h

FIELD EQUIPMENT:
Supply, installation, testing and commissioning
of water level indicator ( Step sensor) for UG
sump / Tank.
3000 mm

54

For Chiller

Supply, installation, testing and commissioning


of immersion type temperature sensor and
thermowell across the chiller pipe (Supply
header,Return header,Supply header before
bypass line and Return header before bypass
line) as per the system requirements for BAS
system

53

Supply, installation, testing and commissioning


of Differential-pressure transducer across the
Chiller header (Supply & Return) as per the
system requirements for BAS system

Amount in Rs.
In words

S.No.

Description

Qty

Unit

Rate
In Figure

Supply, installation, testing and commissioning


of Flow sensor at chilled water flow as per the
system requirements for BAS system
c

Nos

Nos

Nos

Nos

16

Nos

30

Nos

14

Nos

40

Nos

14

Nos

15

Nos

22

Nos

Supply, installation, testing and commissioning


of Ultrasoni meter/BTU meter as per the system
requirements for BAS system
d

55
a

56

Supply, installation, testing and commissioning


of Differential-pressure Switch across the
pumps as per the system requirements for BAS
system
Supply, installation, testing and commissioning
of Pressure transducer across the Chiller
header (Supply & Return) as per the system
requirements for BAS system

For AHU
Supply, installation, testing and commissioning
of immersion type temperature sensor in AHU
CHW Inlet pipe as per the system requirements
for BAS system.
Supply, installation, testing and commissioning
of Temperature (Supply & Return air) with
necessary accessories to monitoring the
conditioned area temperature as per the system
requirements for BAS system
Supply, installation, testing and commissioning
of Duct static pressure sensor to measure the
static pressure in duct as per the AHU I/O listed
for BAS system.
Supply, installation, testing and commissioning
of Differential pressure switch to monitor Filter &
Fan status as per AHU I/O listed for BAS system
Supply, installation, testing and commissioning
of Flow meter to measure the air flow of AHU at
Plenum as per the AHU I/O listed for BAS
system
For TFA
Supply, installation, testing and commissioning
of Temperature (Exhaust & Fresh air) with
necessary accessories to monitoring the
conditioned area temperature as per the system
requirements for BAS system
Supply, installation, testing and commissioning
of Differential pressure switch to monitor Filter &
Fan status as per TFA I/O listed for BAS system

Amount in Rs.
In words

S.No.

Description

Qty

Unit

Rate
In Figure

Supply, installation, testing and commissioning


of outdoor Temperature sensor
c

Nos

Nos

Nos

Nos

20

Nos

Supply, installation, testing and commissioning


of Outdoor CO2 sensor

Nos

For Lift well/stairecase Pressuration Fan


Supply, installation, testing and commissioning
of Differential pressure switch to monitor Filter &
Fan status as per I/O listed for BAS system

20

Nos

4000

Mtrs

2 Core 1.0 sq. mm, armoured Annealed Tinned


Copper conductor multistranded, screened
cable. [For Sensors]

2000

Mtrs

4 Core 1.0 sq. mm, armoured Annealed Tinned


Copper conductor multistranded, screened
cable. [For Sensors]

2000

Mtrs

Supply and laying of Communication cable/bus


cable to intergate all DDCs, BTU meters, VAVs
etc - Armoured

2000

Mtrs

200

Mtrs

57
a

58

Supply, installation, testing and commissioning


of Duct static pressure sensor to measure the
static pressure in duct as per the TFA I/O listed
for BAS system.

Supply, installation, testing and commissioning


of Flow meter to measure the air flow of AHU at
Plenum as per the TFA I/O listed for BAS
system

Supply, installation, testing and commissioning


of immersion type temperature sensor in AHU
CHW Inlet pipe as per the system requirements
for BAS system.

Supply, installation, testing and commissioning


of Indoor CO2 sensor

CABLES / WIRES FOR IBMS


2 Core 1.0 sq. mm, armoured Annealed Tinned
Copper conductor multistranded, Unscreened
cable. [For ON / OFF Command & various
status, Supply for Field Devices]

Supply and laying of 25 mm MS conduit for the


abvoe
e

Amount in Rs.
In words

S.No.

Description

Qty

Unit

Rate
In Figure

3 Core 2.5 Sq.mm copper armoured Cable for


f

1000

Mtrs

250

Mtrs

250

Mtrs

150

Mtrs

Power
A -VI Miscellaneous items
Supply,
Installation,

59

testing

and

Commissioning of the following system


Supply and installation of following size slotted
angle GI ready made cable trays of 14 SWG GI
sheet. The Quoted rates for installation shall
including necessary anchor fasteners and 'L'
angle supports @ 600mm interval etc., to suit
site conditions as required.
150 mm wide

a
300 mm wide
b
450mm wide
c

60

61

62

63

Wiring to the IBMS equipment using 2 R uns of


2.5 Sqmm insulated copper cable and 1R1.5 Sqmmof earthing inside the suitable size GI
3500
conduits with clamp and fixing accessories - The
supply should be taken from existing UPS DB.
Supply of 6 A 3-Pin Socket mounted on PVC
Box which has to be fixed in wall as required.
The Socket should be of modular type
Excavation of ground to a depth of 3' level and
width of 1' and refilling elc.for laying the PVC
piping. Extra earth after fe-filling to be leveled in
low lying area as directed by the Site incharge.
Supply, laying of 110 mm dia 6Kg/cm2 PVC pipe
in execavated ground. The rate shall including
necessary coupler, bend etc.

TOTAL AMOUNT IBMS WORKS

Mtrs

75

Each

400

Mtrs

400

Mtrs

Amount in Rs.
In words

You might also like