Professional Documents
Culture Documents
Item
Properties
Processed in a board form, these products are cost effective and very high in
sound absorption, thermal insulation, and moisture resistance. They are mainly
used for thermal insulation, prevention of dew condensation, and
soundproofing in apartments, ordinary houses, or schools; sound absorption and
thermal insulation in air ducts or machinery rooms; thermal insulation in industrial
facilities; and thermal insulation and fire fighting in ships.
Blanket
The minimum possible number of binders is used to give softness to the product.
Its high flexibility allows the product to be conveniently set up on a curved or rough
surface. This blanket product is usually used for warm/cool keeping and thermal
insulation on the ceilings of buildings, a variety of tanks, or spiral ducts.
Wire Blanket
This product is good for places requiring high durability. It has one side reinforced
with a hexagonal wire net for convenient installation.
Pipe Cover
Formed into a cylinder shape, this mineral wool product is mainly used for thermal
insulation of air-coordinating systems, sanitary facilities, or water-piping systems.
Loose Wool,
Coatrock SWT
Made into a fibrous state, these mineral wool products are mainly used as a filler
for holes on a fire-protection zone or for an oxygen separator, a sound-absorbing
ceiling material, a thermal insulation for ceiling walls, or in other places where
board installation is not allowable.
Because of its extra-strong fireproofing, this product is mainly used as a core
material of sandwich panels requiring high fire-resistant performance.
Panel Core
density
Item
kg/m3
Mineral Wool
Board
Tolerance
40 ~ 150
Thermal Conductivity
W/(mK)
Avg.Temp.70
0.044 or lower
71~100
0.044 or lower
II
101~160
0.043 or lower
161~300
0.044 or lower
Felt
40~70
I
71~100
II
101~160
Band
- 15%,
Don't
define any
+ value.
0.049 or lower
0.052 or lower
0.049 or lower
40~70
0.049 or lower
71~100
0.044 or lower
101~160
0.043 or lower
I
Blanket
II
Pipe Cover
40~200
Hot
Avg. Fiber
Shrinkage Thickness
Temp.
650 or
higher
Particle
Content
7 or lower 4 or lower
600 or
higher
400 or
higher
600 or
higher
400 or
higher
600 or
higher
0.044 or lower
*Note : 1) For those products with an outer cover or surface coating, the hot shrinkage temperature is not applicable.
*cf : 1 W/mK = 0.86 kcal/mh
1) For warm/cool keeping, prevention of dew condensation, or thermal insulation: buildings, air-coordinating systems,
sanitary facilities, the rooftop, outer walls, cold stores, etc.
2) For warm/cool keeping, heat radiation, or thermal insulation: ships, boiler walls, piping, drying furnace, heat treatment
equipment, etc.
3) For sound absorption, noise blocking, or noise prevention: sound facilities, buildings, machinery rooms, electricity
rooms, offices, sports facilities, plants, partitions, etc.
4) For fire safety, fireproofing, or nonflammability: fireproof structures, fireproof partitions, core materials, etc.
5) For agricultural purpose: places where garden products are cultivated.
Standard Size
Standard Size
Density (kg/)
Type
80
100
II
120
140
III
180
200
Thickness(mm)
Width(m)
Length(m)
25
50
75
100
0.5
50
Producible Size
Producible Size
Note
Density (kg/)
Thickness()
40
60-100
50
50-100
60
40-100
80
25-100
100
25-100
120
25-100
140
25-100
150
25-80
180
25-75
200
25-50
Item
Thickness
Thickness Tolerance
Width
450
500
600
Width
Tolerance
Length
Length
Tolerance
I
Board
II
III
30~150
Felt
Band
Blanket
I
II
I
II
+4
-2
30~100
30~150
+5
-2
+5
-3
900
1000
1200
+5
-3
+10
0
900
1000
1200
+15
-3
+30
0
+10
-5
900
1000
+30
0
+5
-3
900
1000
+15
-3
* Note
1. The width and length values allow the integral multiples of standards. In this case, the tolerance is based
on [Dimensional Tolerance] Table.
2. If either of width and length exceeds 200mm, the tolerance does neither allow any minus value nor define
any plus value.
3. If the length of the M/W or G/W blanket exceeds 3000mm, then 3000mm n (n = a natural number) will be
applicable.
4. The length values of the M/W or G/W band and blanket can be determined by mutual agreement, but other
than the above value.
5. For the thickness of a M/W or G/W product, an increment of 5mm will be allowable within a defined range,
adding up 72mm, 74mm, or 84mm if required. In case of more than 400mm thick, two or more length values
may be added.
6. For a compression-packaged(3) G/W Board II, the thickness should be set in prior consideration of the
compression rate. However, the thickness tolerance does neither allow any minus value nor define any plus
value. (3): A compressed package means the state of packaging compressed at more than 10% of a nominal
thickness.