You are on page 1of 108

TKF

Catalogue

Marine

Choose TKF - Choose quality!

BV Twentsche Kabelfabriek
Spinnerstraat 15
P.O. Box 6

Marine & Offshore cables 2012

7480 AA Haaksbergen

International standards

The Netherlands
Tel.: +31 (0)53 573 22 55
E-mail: marine@tkf.nl
Website: www.tkf.eu

Complete range
May 2011
March
2012

Fax: +31 (0)53 573 21 85

Highly flexible cables

www.tkf.nl

Contents

About TKF
Symbols

3
4

Product information
Market search
Marine & Offshore

Terms and Conditions


Reel size and Weight

Copyright (c) TKF, 06-03-2012

103
104

Subject to technical alterations

Page 2

About TKF
Founded in 1930, TKF has developed from a local Dutch cable producer to a cable
technology leader servicing customers all over the world. As a member of TKH
Group NV, a Dutch-based international group of technology-powered companies,
TKF has access to various international marketing, purchasing,
sales and research groups with diverse specialisms.
TKF has dedicated itself to delivering innovative Telecom, Building and Industrial
Solutions that match specific customer needs. A good strategy, looking at the
long-term relationships between TKF and a growing number of companies.
Professionals who value the continuous pursuit of a better understanding
between suppliers, customers, contractors, installers and end-users.
TKF naturally takes its corporate social responsibility into account.
Innovation, Growth and Responsibility are key factors for TKF.

Choose TKF - Choose quality!

Interested in more information about TKF and our


wide range of products and services? Please visit
our website www.tkf.nl for more information.

BV Twentsche Kabelfabriek

Subject to technical alterations

www.tkf.nl-

Symbols

BV Twentsche Kabelfabriek

Subject to technical alterations

www.tkf.nl-

Contents
Marine & Offshore

Low voltage marine cables


MarineLine
MarineLine YZp 0,6/1 kV
MarineLine YOZp 0,6/1 kV
MarineLine YZafp 0,6/1 kV (New)
MarineLine+
MarineLine+ YZp 0,6/1 kV
MarineLine+ YOZp 0,6/1 kV
MarineFlex
MarineFlex YZp 0,6/1 kV
MarineFlex YOZp 0,6/1 kV
MarineFlex YOZp 1,8/3 kV Variable Frequency Drive
MarineMultiFlex BOQp 0,6/1 kV (New)
MarineLine (X)-FR
MarineLine YZp FR 0,6/1 kV
MarineLine YZp X-FR 0,6/1 kV (New)
MarineLine YOZp FR 0,6/1 kV
MarineLine YOZp X-FR 0,6/1 kV (New)
Marineline+ X-FR
MarineLine+ YZp X-FR 0,6/1 kV (New)
MarineLine+ YOZp X-FR 0,6/1 kV (New)
MarineFlex X-FR
MarineFlex YZp X-FR 0,6/1 kV (New)
MarineFlex YOZp X-FR 0,6/1 kV (New)
Medium voltage marine cables
MarinePower YOZmv 3,6/6 kV
MarinePower YZOZmv 3,6/6 kV
MarinePower YOZmv 6/10 kV
MarinePower YZOZmv 6/10 kV
MarinePowerFlex YZOZmv 6/10 kV
MarinePower MultiFlex YQOQmv 6/10 kV
MarinePower YOZmv 8,7/15 kV
MarinePower YZOZmv 8,7/15 kV
MarinePower YOZmv 12/20 kV
MarinePower YZOZmv 12/20 kV
MarinePower YOZmv 18/30 kV
MarinePower YZOZmv 18/30 kV
Communication marine cables
MarineCom
MarineCom YOZc 250 V
MarineCom YOZc X-FR 250 V (New)

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

8
11
14
16
18
20
22
24
26
27
29
32
35
38
40
42
44
46
48
50
52
54
55
56
58
60
62
64
66

67
71

Page 5

Contents
Marine & Offshore

MarineCom YZafc 250 V (New)


Marine2Com YOZ2c 250 V
Marine2Com YZ2afc 250 V (New)
Marine2Com YOZ2c X-FR 250 V (New)
Signal marine cables
MarineSignal
MarineSignal YZs 250 V
MarineSignal YOZs 250 V
MarineSignal+
MarineSignal+ YZs 250 V
MarineSignal+ YOZs 250 V
Fibre Optic cables
Breakout Cables
SM G.657A
LSZH CWB MM
8x MM 62,5/125 + 2x 1,5mm2
Appendix

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

74
77
80
83

85
87
89
90

91
93
94
95

Page 6

MarineLine
Unbraided, braided or screened power cables
YZp, YOZp, YZafp 0,6/1kV

MarineLine+
Filled, unbraided or braided power cables
YZp, YOZp 0,6/1kV

MarineFlex
Flexible power cables unbraided or braided
YZP, YOZP, MultiFlex BOQp 0,6/3kV

MarineLine (X-)FR
Fire Resistant power cables unbraided or braided
YZp (X-)FR, YOZp (X-)FR 0,6/1kV

MarineLine+ X-FR
Fire Resistant power cables unbraided or braided
YZp X-FR , YOZp X-FR 0,6/1kV

MarineFlex X-FR
Flexible Fire Resistant power cables unbraided or braided
YZp X-FR, YOZp X-FR 0,6/1kV

MarinePower(Flex) (Multiflex)
Flexible Medium Voltage cables for special applications
YOZmv, YZOZmv, YQOQmv 3,6/30kV

MarineCom
Braided or screened twisted pair communication cables
YOZc, YZafc, YOZ2c 250V

Marine2Com X-FR
Fire Resistant communication cables
YOZc, YOZ2c X-FR 250V

Marine2Com
Fire Resistant communication cables
YOZ2c, YZ2afc 250V

MarineSignal, MarineSignal+
Signaling cables
YZs, YOZs 250V

Fibre Optic
Multimode or Singlemode Fibre Optic cables, with or without copper braid
SM G.657A1, LSZH CWBKMaMb,e8lxfMamM 6il2i,e5/125 + 2 x 1,5 mm2

BV Twentsche Kabelfabriek

Subject to technical alterations

www.tkf.nl

Marine & Offshore


MarineLine YZp 0,6/1 kV

Lightweight, reduced diameter low voltage power cables for power and lighting applications in all
ship areas. High abrasion resistant sheath and easily strippable with ripcord.
Halogen-free and low-smoke , flame-retardant in fire conditions.
Different sheath colours available on request.

Characteristics

Properties Unit
Low voltage marine cables
Shipboard cable

Product group
Series

Type
MarineLine YZp 0,6/1 kV
Standardization
IEC 60092-350/-351/-353
Flame retardant
IEC 60332-1 / IEC 60332-3-22 Cat. A
Halogen free
IEC 60754-1
Conductor material
Cu
Conductor category
Class 2 = stranded
Shape of conductor
Article dependant, see detail sheet
Core insulation
XLPE
Core identification
HD 308 S2
Material outer sheath Flame Retardant Halogen Free Polyolefin Compound
Colour outer sheath
Black
Nominal voltage U0
0.6
Nominal voltage U
1
Maximum conductor temperature
90
Operating temperature, flexible
-20 / 70
Operating temperature, fixed
-40 / 70
Specification
See appendix

Partnumber Construction
16560
2 x 1 mm

Shape
of
conductor
Round

Net
weight
(kg/km)
56

Bending
radius
after
installation
(mm)
30

15969
15970
15971
15972
16000
16001
16002
16003
16004
16005
16006

Round
Round
Round
Round
Round
Round
Round
Round
Round
Round
Round

92
114
138
179
36
68
92
114
138
169
179

34
37
40
45
20
32
34
37
40
45
45

3 G 1,5 mm
4 G 1,5 mm
5 G 1,5 mm
7 G 1,5 mm
1 x 1,5 mm
2 x 1,5 mm
3 x 1,5 mm
4 x 1,5 mm
5 x 1,5 mm
6 x 1,5 mm
7 x 1,5 mm

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

kV
kV
C
C
C

Outer
diameter
approx.
(mm)
7,4

Tensile
load
(N)
30

8,5
9,3
10,1
11,2
4,9
7,9
8,5
9,3
10,1
11,2
11,2

68
90
113
158
23
45
68
90
113
135
158

Page 8

Marine & Offshore


MarineLine YZp 0,6/1 kV

Partnumber Construction

Shape
of
conductor

Net
weight
(kg/km)

Bending
radius
after
installation
(mm)

Outer
diameter
approx.
(mm)

Tensile
load
(N)

16007
16008
16009
16010
16011
16012
15999

8 x 1,5 mm
10 x 1,5 mm
12 x 1,5 mm
16 x 1,5 mm
19 x 1,5 mm
24 x 1,5 mm
27 x 1,5 mm

Round
Round
Round
Round
Round
Round
Round

223
289
292
385
443
576
609

52
62
59
68
72
81
85

13
15,6
14,8
16,9
18,1
20,2
21,2

180
225
270
360
428
540
608

15973
15974
15975
15976
16013
16014
16015
16016
16017
16018

3 G 2,5 mm
4 G 2,5 mm
5 G 2,5 mm
7 G 2,5 mm
1 x 2,5 mm
2 x 2,5 mm
3 x 2,5 mm
4 x 2,5 mm
5 x 2,5 mm
7 x 2,5 mm

Round
Round
Round
Round
Round
Round
Round
Round
Round
Round

126
157
197
251
47
95
126
157
197
251

38
42
46
50
21
36
38
42
46
50

9,5
10,4
11,5
12,6
5,3
9
9,5
10,4
11,5
12,6

113
150
188
263
38
75
113
150
188
263

15977
15978
17752
16019
16020
16021
16022

3 G 4 mm
4 G 4 mm
1 x 4 mm
1 x 4 mm
2 x 4 mm
3 x 4 mm
4 x 4 mm

Round
Round
Round
Round
Round
Round
Round

176
230
64
64
133
179
230

43
48
24
24
40
43
48

10,7
11,9
5,9
5,9
10,1
10,7
11,9

180
240
60
60
120
180
240

15979
15980
17753
16023
16024
16025
16026

3 G 6 mm
4 G 6 mm
1 x 6 mm
1 x 6 mm
2 x 6 mm
3 x 6 mm
4 x 6 mm

Round
Round
Round
Round
Round
Round
Round

245
316
86
86
185
245
316

48
53
26
26
46
48
53

12,1
13,2
6,4
6,4
11,4
12,1
13,2

270
360
90
90
180
270
360

15981
15982
17754
16027
16028
16029
16030

3 G 10 mm
4 G 10 mm
1 x 10 mm
1 x 10 mm
2 x 10 mm
3 x 10 mm
4 x 10 mm

Round
Round
Round
Round
Round
Round
Round

375
486
127
127
266
375
486

55
61
29
29
52
55
61

13,8
15,2
7,2
7,2
12,9
13,8
15,2

450
600
150
150
300
450
600

16031
16032
16033
16034

1 x 16 mm
2 x 16 mm
3 x 16 mm
4 x 16 mm

Round
Round
Round
Round

186
393
553
728

33
60
64
71

8,2
15,1
16
17,8

240
480
720
960

16035

1 x 25 mm

Round

288

40

10,1

375

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

Page 9

Marine & Offshore


MarineLine YZp 0,6/1 kV

Partnumber Construction

Shape
of
conductor

Net
weight
(kg/km)

Bending
radius
after
installation
(mm)

Outer
diameter
approx.
(mm)

Tensile
load
(N)

16036
16037
16038

2 x 25 mm
3 x 25 mm
4 x 25 mm

Round
Round
Round

603
862
1141

75
80
89

18,7
20
22,3

750
1125
1500

16039
16040
16048

1 x 35 mm
2 x 35 mm
3 x 35 mm

Round
Round
Sector-shaped

386
805
1255

47
88
83

11,8
22,1
20,8

525
1050
1575

16041
16049

1 x 50 mm
3 x 50 mm

Round
Sector-shaped

515
1623

53
94

13,2
23,4

750
2250

16042
16050

1 x 70 mm
3 x 70 mm

Round
Sector-shaped

725
2218

62
108

15,4
27,1

1050
3150

16043
16051

1 x 95 mm
3 x 95 mm

Round
Sector-shaped

992
3076

70
125

17,5
31,3

1425
4275

17755
16044
16052

1 x 120 mm
1 x 120 mm
3 x 120 mm

Round
Round
Sector-shaped

1244
1236
3817

78
78
139

19,5
19,5
34,7

1800
1800
5400

16045
16053

1 x 150 mm
3 x 150 mm

Round
Sector-shaped

1510
4776

86
152

21,5
37,9

2250
6750

16046
16054

1 x 185 mm
3 x 185 mm

Round
Sector-shaped

1896
5850

96
164

24
41

2775
8325

16047
16055

1 x 240 mm
3 x 240 mm

Round
Sector-shaped

2445
7676

162
190

27
47,6

3600
10800

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

Page 10

Marine & Offshore


MarineLine YOZp 0,6/1 kV

Armoured, lightweight, reduced diameter low voltage cables for power and lighting applications
in all ship areas where extra mechanical and EMC protection is needed.
The tinned copper braid is highly corrosion resistant which ensures a long cable lifetime.
Halogen-free and low-smoke , flame-retardant in fire conditions.
Characteristics

Properties Unit
Low voltage marine cables
Shipboard cable
MarineLine YOZp 0,6/1 kV

Product group
Series
Type

Standardization
IEC 60092-350/-351/-353
Flame retardant
IEC 60332-1 / IEC 60332-3-22 Cat. A
Halogen free
IEC 60754-1
Conductor material
Cu
Conductor category
Class 2 = stranded
Shape of conductor
Article dependant, see detail sheet
Core insulation
XLPE
Core identification
HD 308 S2
Construction outer shield
Tinned copper braiding
Material outer sheath Flame Retardant Halogen Free Polyolefin Compound
Colour outer sheath
Black
Nominal voltage U0
0.6
Nominal voltage U
1
Maximum conductor temperature
90
Operating temperature, flexible
-20 / 70
Operating temperature, fixed
-40 / 70
Specification
See appendix

Partnumber
15985
15986
16110
16111
16112
16113
16114
16115
16116
16117
16118
16119
16120

Construction
4 G 1,5 mm
5 G 1,5 mm
1 x 1,5 mm
2 x 1,5 mm
3 x 1,5 mm
4 x 1,5 mm
5 x 1,5 mm
6 x 1,5 mm
7 x 1,5 mm
8 x 1,5 mm
10 x 1,5 mm
12 x 1,5 mm
16 x 1,5 mm

Copyright (c) TKF, 06-03-2012

Shape
of
conductor
Round
Round
Round
Round
Round
Round
Round
Round
Round
Round
Round
Round
Round

Net
weight
(kg/km)
159
192
60
110
131
158
192
222
232
314
386
398
505

Bending
radius
after
installation
(mm)
41
45
23
36
38
41
45
48
49
56
63
64
73

Subject to technical alterations

kV
kV
C
C
C

Outer
diameter
approx.
(mm)
10,2
11,2
5,8
9
9,4
10,2
11,2
12,1
12,2
13,9
15,7
16,1
18,2

Tensile
load
(N)
90
113
23
45
68
90
113
135
158
180
225
270
360

Page 11

Marine & Offshore


MarineLine YOZp 0,6/1 kV

Partnumber Construction

Shape
of
conductor

Net
weight
(kg/km)

Bending
radius
after
installation
(mm)

Outer
diameter
approx.
(mm)

Tensile
load
(N)

16121
16122
16159
16185

19 x 1,5 mm
24 x 1,5 mm
27 x 1,5 mm
37 x 1,5 mm

Round
Round
Round
Round

582
722
784
1014

76
86
91
104

19
21,5
22,7
26,1

428
540
608
833

15987
15988
15989
16123
16124
16125
16126
16127
16128
16429

3 G 2,5 mm
4 G 2,5 mm
5 G 2,5 mm
1 x 2,5 mm
2 x 2,5 mm
3 x 2,5 mm
4 x 2,5 mm
5 x 2,5 mm
7 x 2,5 mm
19 x 2,5 mm

Round
Round
Round
Round
Round
Round
Round
Round
Round
Round

171
211
250
71
137
170
209
250
354
793

42
46
50
25
40
42
46
50
56
87

10,4
11,5
12,4
6,2
9,9
10,4
11,4
12,4
14,1
21,7

113
150
188
38
75
113
150
188
263
713

16129
16130
16131
16132

1 x 4 mm
2 x 4 mm
3 x 4 mm
4 x 4 mm

Round
Round
Round
Round

92
184
230
286

27
44
47
51

6,8
11,1
11,7
12,7

60
120
180
240

16133
16134
16135
16136

1 x 6 mm
2 x 6 mm
3 x 6 mm
4 x 6 mm

Round
Round
Round
Round

117
235
302
419

29
49
52
59

7,3
12,3
12,9
14,8

90
180
270
360

16137
16138
16139
16140

1 x 10 mm
2 x 10 mm
3 x 10 mm
4 x 10 mm

Round
Round
Round
Round

162
368
472
611

32
57
60
67

8,1
14,3
15,1
16,7

150
300
450
600

16141
16142
16143
16144

1 x 16 mm
2 x 16 mm
3 x 16 mm
4 x 16 mm

Round
Round
Round
Round

229
508
678
870

37
66
70
77

9,3
16,5
17,5
19,3

240
480
720
960

16145
16146
16147
16148

1 x 25 mm
2 x 25 mm
3 x 25 mm
4 x 25 mm

Round
Round
Round
Round

342
748
1010
1306

45
80
85
94

11,2
20,1
21,3
23,6

375
750
1125
1500

16158
16157
16149
16426

1 x 35 mm
2 x 35 mm
3 x 35 mm
4 x 35 mm

Round
Round
Sector-shaped
Sector-shaped

476
981
1371
1691

53
94
86
95

13,2
23,4
21,6
23,8

525
1050
1575
2100

16401
16150
16427

1 x 50 mm
3 x 50 mm
4 x 50 mm

Round
Sector-shaped
Sector-shaped

621
1776
2304

59
96
107

14,7
23,9
26,8

750
2250
3000

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

Page 12

Marine & Offshore


MarineLine YOZp 0,6/1 kV

Partnumber Construction

Shape
of
conductor

Net
weight
(kg/km)

Bending
radius
after
installation
(mm)

Outer
diameter
approx.
(mm)

Tensile
load
(N)

16402
16151

1 x 70 mm
3 x 70 mm

Round
Sector-shaped

854
2417

66
112

16,6
28

1050
3150

16403
16152

1 x 95 mm
3 x 95 mm

Round
Sector-shaped

1129
3285

75
128

18,7
32,1

1425
4275

16404
16153

1 x 120 mm
3 x 120 mm

Round
Sector-shaped

1397
4141

82
142

20,5
35,5

1800
5400

16405
17191
16154
16183

1 x 150 mm
1 x 150 mm
3 x 150 mm
4 x 150 mm

Round
Round
Sector-shaped
Sector-shaped

1684
1689
5158
6643

90
90
159
181

22,6
22,6
39,7
45,3

2250
2250
6750
9000

16406
16155

1 x 185 mm
3 x 185 mm

Round
Sector-shaped

2087
6269

101
171

25,3
42,8

2775
8325

16407
16156

1 x 240 mm
3 x 240 mm

Round
Sector-shaped

2658
8164

112
198

27,9
49,5

3600
10800

16433
16434

1 x 300 mm
3 x 300 mm

Round
Sector-shaped

3271
10001

126
206

31,6
51,4

4500
13500

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

Page 13

Marine & Offshore


MarineLine YZafp 0,6/1 kV

Alpet taped screen, lightweight, reduced diameter low voltage cables for power and lighting applications
in all ship areas where EMC protection is needed.
High abrasion resistant sheath and easily strippable with ripcord.
Halogen-free and low-smoke, flame-retardant in fire conditions.
Characteristics

Properties Unit
Low voltage marine cables
Shipboard cable
MarineLine YZafp 0,6/1 kV

Product group
Series
Type

Standardization
IEC 60092-350/-351/-353
Flame retardant
IEC 60332-1 / IEC 60332-3-22 Cat. A
Halogen free
IEC 60754-1
Conductor material
Cu
Conductor category
Class 2 = stranded
Shape of conductor
Round
Core insulation
XLPE
Core identification
HD 308 S2
Construction outer shield
Alpet tape
Drain wire
Yes
Material outer sheath Flame Retardant Halogen Free Polyolefin Compound
Colour outer sheath
Black
Nominal voltage U0
0.6
Nominal voltage U
1
Maximum conductor temperature
90
Operating temperature, flexible
-20 / 70
Operating temperature, fixed
-40 / 70
Specification
See appendix

Construction
Partnumber
16670
16671
16672
16676
16601
16602
16603
16604
16605
16606
16607
16609

G=Y/G
3 G 1,5 mm
4 G 1,5 mm
5 G 1,5 mm
7 G 1,5 mm
2 x 1,5 mm
3 x 1,5 mm
4 x 1,5 mm
5 x 1,5 mm
6 x 1,5 mm
7 x 1,5 mm
8 x 1,5 mm
10 x 1,5 mm

Copyright (c) TKF, 06-03-2012

Shape
of
conductor
Round
Round
Round
Round
Round
Round
Round
Round
Round
Round
Round
Round

Net
weight
(kg/km)
101
122
144
189
77
101
122
147
179
190
234
301

Bending
radius
after
installation
(mm)
70
76
83
92
65
70
76
82
91
91
106
126

Subject to technical alterations

kV
kV
C
C
C

Outer
diameter
approx.
(mm)
8,8
9,5
10,4
11,5
8,1
8,8
9,5
10,3
11,4
11,4
13,2
15,8

Tensile
load
(N)
68
90
113
158
45
68
90
113
135
158
180
225

Page 14

Marine & Offshore


MarineLine YZafp 0,6/1 kV

Partnumber G=Y/G

Shape
of
conductor

Net
weight
(kg/km)

Bending
radius
after
installation
(mm)

Outer
diameter
approx.
(mm)

Tensile
load
(N)

16611
16615
16618
16623
16626
16627
16628

12 x 1,5 mm
16 x 1,5 mm
19 x 1,5 mm
24 x 1,5 mm
27 x 1,5 mm
30 x 1,5 mm
37 x 1,5 mm

Round
Round
Round
Round
Round
Round
Round

304
398
455
597
623
683
831

120
136
146
163
171
180
198

15
17
18,3
20,4
21,4
22,5
24,8

270
360
428
540
608
675
833

16673
16674
16675
16677
16631
16632
16633
16634
16635
16636
16637
16639
16641
16645
16648
16653
16656
16657
16658

3 G 2,5 mm
4 G 2,5 mm
5 G 2,5 mm
7 G 2,5 mm
2 x 2,5 mm
3 x 2,5 mm
4 x 2,5 mm
5 x 2,5 mm
6 x 2,5 mm
7 x 2,5 mm
8 x 2,5 mm
10 x 2,5 mm
12 x 2,5 mm
16 x 2,5 mm
19 x 2,5 mm
24 x 2,5 mm
27 x 2,5 mm
30 x 2,5 mm
37 x 2,5 mm

Round
Round
Round
Round
Round
Round
Round
Round
Round
Round
Round
Round
Round
Round
Round
Round
Round
Round
Round

134
166
209
264
106
132
167
208
247
264
329
401
436
561
657
839
904
1005
1212

78
85
94
102
74
78
85
94
103
103
115
132
138
155
169
188
198
208
228

9,7
10,6
11,8
12,8
9,2
9,7
10,6
11,8
12,9
12,9
14,4
16,5
17,2
19,4
21,1
23,5
24,7
26
28,5

113
150
188
263
75
113
150
188
225
263
300
375
450
600
713
900
1013
1125
1388

Construction

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

Page 15

Marine & Offshore


MarineLine+ YZp 0,6/1 kV

Low voltage cables for power and lighting applications for fixed installation in all ship areas.
The MarineLine+ cables have an extruded inner bedding and are suitable for heavy duty
applications and grant optimal sealing in cable transits.
High abrasion resistant sheath and easily strippable with ripcord.
Halogen-free and low-smoke, flame-retardant in fire conditions.

Characteristics

Properties Unit
Low voltage marine cables

Product group

Series
Shipboard cable
Type
MarineLine+ YZp 0,6/1 kV
Standardization
IEC 60092-350/-351/-353
Flame retardant
IEC 60332-1 / IEC 60332-3-22 Cat. A
Halogen free
IEC 60754-1
Conductor material
Cu
Conductor category
Class 2 = stranded
Shape of conductor
Round
Core insulation
XLPE
Core identification
HD 308 S2
Material outer sheath Flame Retardant Halogen Free Polyolefin Compound
Colour outer sheath
Black
Nominal voltage U0
0.6
Nominal voltage U
1
Maximum conductor temperature
90
Operating temperature, flexible
-20 / 70
Operating temperature, fixed
-40 / 70
Specification
See appendix

Construction
Partnumber
16420
16419
16418
16060
16061
16062
16063

G=Y/G
3 G 1,5 mm
4 G 1,5 mm
5 G 1,5 mm
2 x 1,5 mm
3 x 1,5 mm
4 x 1,5 mm
5 x 1,5 mm

Shape
of
conductor
Round
Round
Round
Round
Round
Round
Round

16417
16416
16415
16064

3 G 2,5 mm
4 G 2,5 mm
5 G 2,5 mm
2 x 2,5 mm

Round
Round
Round
Round

Copyright (c) TKF, 06-03-2012

Net
weight
(kg/km)
125
143
177
119
125
143
178

Bending
radius
after
installation
(mm)
36
39
43
36
36
39
43

170
204
255
139

41
45
50
38

Subject to technical alterations

kV
kV
C
C
C

Outer
diameter
approx.
(mm)
9
9,7
10,7
9
9
9,7
10,7

Tensile
load
(N)
68
90
113
45
68
90
113

10,2
11,2
12,5
9,4

113
150
188
75

Page 16

Marine & Offshore


MarineLine+ YZp 0,6/1 kV

Partnumber G=Y/G

Shape
of
conductor

Net
weight
(kg/km)

Bending
radius
after
installation
(mm)

Outer
diameter
approx.
(mm)

Tensile
load
(N)

16065
16066
16067

3 x 2,5 mm
4 x 2,5 mm
5 x 2,5 mm

Round
Round
Round

169
204
255

41
45
50

10,2
11,2
12,5

113
150
188

16084
16068
16069
16070

3 G 4 mm
2 x 4 mm
3 x 4 mm
4 x 4 mm

Round
Round
Round
Round

246
198
246
297

47
43
47
51

11,8
10,8
11,8
12,8

180
120
180
240

16085
16071
16072
16073

3 G 6 mm
2 x 6 mm
3 x 6 mm
4 x 6 mm

Round
Round
Round
Round

317
270
317
389

51
49
51
56

12,8
12,2
12,8
14

270
180
270
360

16083
16074
16075
16076

4 G 10 mm
2 x 10 mm
3 x 10 mm
4 x 10 mm

Round
Round
Round
Round

592
384
477
592

64
56
59
64

16,1
13,9
14,8
16,1

600
300
450
600

16086
16077
16078
16079

5 G 16 mm
2 x 16 mm
3 x 16 mm
4 x 16 mm

Round
Round
Round
Round

1045
558
698
851

82
65
68
74

20,4
16,2
17,1
18,4

1200
480
720
960

16080
16081
16082

2 x 25 mm
3 x 25 mm
4 x 25 mm

Round
Round
Round

870
1066
1349

80
84
93

20,1
21
23,2

750
1125
1500

Construction

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

Page 17

Marine & Offshore


MarineLine+ YOZp 0,6/1 kV

Armoured low voltage cables for power and lighting applications for fixed installation in all ship areas
where extra mechanical and EMC protection is needed.
The tinned copper braid is highly corrosion resistant and provides optimal screening.
Suitable for heavy duty applications and grants optimal sealing in cable transits due to its extruded filler.

Characteristics

Properties
Product group
Low voltage marine cables
Series
Shipboard cable
Type
MarineLine+ YOZp 0,6/1 kV
Standardization
IEC 60092-350/-351/-353
Flame retardant
IEC 60332-1 / IEC 60332-3-22 Cat. A
Halogen free
IEC 60754-1
Conductor material
Cu
Conductor category
Class 2 = stranded
Shape of conductor
Round
Core insulation
XLPE
Core identification
HD 308 S2
Construction outer shield
Tinned copper braiding
Material outer sheath Flame Retardant Halogen Free Polyolefin Compound
Colour outer sheath
Black
Nominal voltage U0
0.6
Nominal voltage U
1
Maximum conductor temperature
90
Operating temperature, flexible
-20 / 70
Operating temperature, fixed
-40 / 70
Specification
See appendix

Construction
Partnumber
16414
16413
16412
16160
16161
16162
16163

G=Y/G
3 G 1,5 mm
4 G 1,5 mm
5 G 1,5 mm
2 x 1,5 mm
3 x 1,5 mm
4 x 1,5 mm
5 x 1,5 mm

Shape
of
conductor
Round
Round
Round
Round
Round
Round
Round

16411

3 G 2,5 mm

Round

Copyright (c) TKF, 06-03-2012

Net
weight
(kg/km)
216
244
276
192
216
244
276

Bending
radius
after
installation
(mm)
46
48
52
43
46
48
52

266

49

Subject to technical alterations

Unit

kV
kV
C
C
C

Outer
diameter
approx.
(mm)
11,4
12,1
12,9
10,7
11,4
12,1
12,9

Tensile
load
(N)
68
90
113
45
68
90
113

12,3

113

Page 18

Marine & Offshore


MarineLine+ YOZp 0,6/1 kV

Partnumber G=Y/G

Shape
of
conductor

Net
weight
(kg/km)

Bending
radius
after
installation
(mm)

Outer
diameter
approx.
(mm)

Tensile
load
(N)

16410
16409
16164
16165
16166
16167

4 G 2,5 mm
5 G 2,5 mm
2 x 2,5 mm
3 x 2,5 mm
4 x 2,5 mm
5 x 2,5 mm

Round
Round
Round
Round
Round
Round

348
394
238
266
348
394

56
60
47
49
56
60

13,9
14,9
11,8
12,3
13,9
14,9

150
188
75
113
150
188

16186
16168
16169
16170

3 G 4 mm
2 x 4 mm
3 x 4 mm
4 x 4 mm

Round
Round
Round
Round

378
293
378
441

56
51
56
60

14,1
12,8
14,1
15,1

180
120
180
240

16187
16171
16172
16173

3 G 6 mm
2 x 6 mm
3 x 6 mm
4 x 6 mm

Round
Round
Round
Round

473
408
473
563

62
59
62
67

15,4
14,7
15,4
16,7

270
180
270
360

16428
16174
16175
16176

3 G 10 mm
2 x 10 mm
3 x 10 mm
4 x 10 mm

Round
Round
Round
Round

641
541
641
774

69
65
69
74

17,2
16,2
17,2
18,5

450
300
450
600

16188
16177
16178
16179

5 G 16 mm
2 x 16 mm
3 x 16 mm
4 x 16 mm

Round
Round
Round
Round

1299
734
889
1080

93
74
78
85

23,2
18,4
19,5
21,2

1200
480
720
960

16180
16181
16182

2 x 25 mm
3 x 25 mm
4 x 25 mm

Round
Round
Round

1063
1297
1593

88
93
102

22,1
23,3
25,5

750
1125
1500

Construction

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

Page 19

Marine & Offshore


MarineFlex YZp 0,6/1 kV

These extra flexible low voltage cables for fixed installation ensure easy installation, also in tight
spaces and for bigger conductor sizes.
The sheath material has excellent abrasion resistance properties and can be stripped easily with
the ripcord. Halogen-free and low-smoke, flame-retardant in fire conditions.
Different sheath colours available on request.
Characteristics

Properties Unit
Low voltage marine cables
Shipboard cable

Product group
Series

Type
MarineFlex YZp 0,6/1 kV
Standardization
IEC 60092-350/-351/-353
Flame retardant
IEC 60332-1 / IEC 60332-3-22 Cat. A
Halogen free
IEC 60754-1
Conductor material
Cu
Conductor category
Class 5 = flexible
Shape of conductor
Round
Core insulation
XLPE
Core identification
HD 308 S2
Material outer sheath Flame Retardant Halogen Free Polyolefin Compound
Colour outer sheath
Black
Nominal voltage U0
0.6
Nominal voltage U
1
Maximum conductor temperature
90
Operating temperature, flexible
-20 / 70
Operating temperature, fixed
-40 / 70
Specification
See appendix

Construction

Net
weight
(kg/km)
375
1139
1474
1892

Bending
radius
after
installation
(mm)
48
93
103
116

kV
kV
C
C
C

Outer
diameter
approx.
(mm)
11,9
23,3
25,8
28,9

Tensile
load
(N)
525
1050
1575
2100

Partnumber
16090
16091
16092
16438

G=Y/G
1 x 35 mm
2 x 35 mm
3 x 35 mm
4 x 35 mm

Shape
of
conductor
Round
Round
Round
Round

16093
16094
16439

1 x 50 mm
3 x 50 mm
4 x 50 mm

Round
Round
Round

500
1968
2542

54
118
132

13,4
29,4
33,1

750
2250
3000

16095
16096
16440

1 x 70 mm
3 x 70 mm
4 x 70 mm

Round
Round
Round

698
2726
3448

62
137
152

15,6
34,3
37,9

1050
3150
4200

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

Page 20

Marine & Offshore


MarineFlex YZp 0,6/1 kV

Partnumber G=Y/G

Shape
of
conductor

Net
weight
(kg/km)

Bending
radius
after
installation
(mm)

Outer
diameter
approx.
(mm)

Tensile
load
(N)

16097
16098
16441

1 x 95 mm
3 x 95 mm
4 x 95 mm

Round
Round
Round

907
3519
4464

70
153
168

17,4
38,2
42,1

1425
4275
5700

16099
16100
16442

1 x 120 mm
3 x 120 mm
4 x 120 mm

Round
Round
Round

1154
4472
5717

78
170
170

19,4
42,6
42,6

1800
5400
5400

16101
16102

1 x 150 mm
3 x 150 mm

Round
Round

1427
5543

86
190

21,4
47,4

2250
6750

16103
16104

1 x 185 mm
3 x 185 mm

Round
Round

1709
6652

94
208

23,6
52,1

2775
8325

16105
16106

1 x 240 mm
3 x 240 mm

Round
Round

2316
8877

107
236

26,8
59

3600
10800

16107

1 x 300 mm

Round

2604

123

30,8

4500

Construction

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

Page 21

Marine & Offshore


MarineFlex YOZp 0,6/1 kV

TKF: Shipboard cable MarineFlex YOZp 0,6/1 kV


These armoured extra flexible low voltage cables for fixed installation ensure easy installation,
also in tight spaces and for bigger conductor sizes.
The tinned copper braid with a high coverage density is highly corrosion resistant and provides
good EMC and mechanical protection. Halogen-free and low-smoke, flame-retardant in fire conditions.
Characteristics

Properties Unit
Low voltage marine cables
Shipboard cable

Product group
Series

Type
MarineFlex YOZp 0,6/1 kV
Standardization
IEC 60092-350/-351/-353
Flame retardant
IEC 60332-1 / IEC 60332-3-22 Cat. A
Halogen free
IEC 60754-1
Conductor material
Cu
Conductor category
Class 5 = flexible
Shape of conductor
Round
Core insulation
XLPE
Core identification
HD 308 S2
Construction outer shield
Tinned copper braiding
Material outer sheath Flame Retardant Halogen Free Polyolefin Compound
Colour outer sheath
Black
Nominal voltage U0
0.6
Nominal voltage U
1
Maximum conductor temperature
90
Operating temperature, flexible
-20 / 70
Operating temperature, fixed
-40 / 70
Specification
See appendix

Construction

Net
weight
(kg/km)
464
1659
2063

Bending
radius
after
installation
(mm)
53
108
118

kV
kV
C
C
C

Outer
diameter
approx.
(mm)
13,2
26,9
29,6

Tensile
load
(N)
525
1575
2100

Partnumber
16190
16191
16192

G=Y/G
1 x 35 mm
3 x 35 mm
4 x 35 mm

Shape
of
conductor
Round
Round
Round

16193
16194
16195

1 x 50 mm
3 x 50 mm
4 x 50 mm

Round
Round
Round

614
2211
2781

60
123
137

14,9
30,7
34,2

750
2250
3000

16196
16197
16198

1 x 70 mm
3 x 70 mm
4 x 70 mm

Round
Round
Round

829
3062
3812

68
144
158

17,1
36
39,6

1050
3150
4200

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

Page 22

Marine & Offshore


MarineFlex YOZp 0,6/1 kV

Partnumber G=Y/G

Shape
of
conductor

Net
weight
(kg/km)

Bending
radius
after
installation
(mm)

Outer
diameter
approx.
(mm)

Tensile
load
(N)

16199
16200
16201

1 x 95 mm
3 x 95 mm
4 x 95 mm

Round
Round
Round

1044
4014
5012

75
159
175

18,7
39,7
43,8

1425
4275
5700

16202
16203
16443

1 x 120 mm
3 x 120 mm
4 x 120 mm

Round
Round
Round

1296
4968
6269

83
176
194

20,7
43,9
48,4

1800
5400
7200

16204
16205

1 x 150 mm
3 x 150 mm

Round
Round

1606
6091

92
196

23
49,1

2250
6750

16206
16207

1 x 185 mm
3 x 185 mm

Round
Round

1919
7247

101
214

25,2
53,6

2775
8325

16208
16209

1 x 240 mm
3 x 240 mm

Round
Round

2537
9549

114
243

28,4
60,7

3600
10800

Construction

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

Page 23

Marine & Offshore


MarineFlex YOZp 1,8/3 kV

Special Frequency Drive cables.


These cables have increased isolation thickness to withstand voltage spikes that can occur in
low-voltage frequency drives, and to withstand accelerated aging of the insulation material due
to higher frequencies. The tinned copper wire braiding offers excellent EMI protection and
mechanical protection. Special types available on request.
Characteristics

Properties Unit
Low voltage marine cables
Shipboard cable

Product group
Series

Type
MarineFlex YOZp 1,8/3 kV
Standardization
IEC 60092-350/-351/-353
Flame retardant
IEC 60332-1 / IEC 60332-3-22 Cat. A
Halogen free
IEC 60754-1
Conductor material
Cu
Conductor category
Class 5 = flexible
Shape of conductor
Round
Core insulation
XLPE
Core identification
HD 308 S2
Construction outer shield
Tinned copper braiding
Material outer sheath Flame Retardant Halogen Free Polyolefin Compound
Colour outer sheath
Black
Nominal voltage U0
1.8
Nominal voltage U
3
Maximum conductor temperature
90
Operating temperature, flexible
-20 / 70
Operating temperature, fixed
-40 / 70
Specification
See appendix

kV
kV
C
C
C

Partnumber Construction
16507
1 x 35 mm
16515
3 x 35 mm

Shape
of
conductor
Round
Round

Net
weight
(kg/km)
536
1993

Bending
radius
after
installation
(mm)
62
128

16508
16516

1 x 50 mm
3 x 50 mm

Round
Round

679
2595

68
142

17,1
35,5

750
2250

16509
16517

1 x 70 mm
3 x 70 mm

Round
Round

889
3414

76
160

18,9
40

1050
3150

16510
16518

1 x 95 mm
3 x 95 mm

Round
Round

1121
4411

83
175

20,7
43,8

1425
4275

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

Outer
diameter
approx.
(mm)
15,6
31,9

Tensile
load
(N)
525
1575

Page 24

Marine & Offshore


MarineFlex YOZp 1,8/3 kV

Partnumber Construction

Shape
of
conductor

Net
weight
(kg/km)

Bending
radius
after
installation
(mm)

Outer
diameter
approx.
(mm)

Tensile
load
(N)

16511
16519

1 x 120 mm
3 x 120 mm

Round
Round

1371
5365

90
190

22,5
47,6

1800
5400

16512
16520

1 x 150 mm
3 x 150 mm

Round
Round

1652
6399

96
207

24,1
51,8

2250
6750

16513
16521

1 x 185 mm
3 x 185 mm

Round
Round

1965
7494

104
222

25,9
55,4

2775
8325

16514

1 x 240 mm

Round

2564

116

29

3600

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

Page 25

Marine & Offshore


MarineMultiFlex BOQp 0,6/1 kV

Special flexible cables for when repeated bending is required and for operating in harsh environments,
such as in retractable azipod drives, powering underwater dredger motors, and use in cable chains.
Special construction and materials ensures a long lifetime in demanding conditions,
and a special combined EMI screening for use in frequency drive applications.
Characteristics

Properties Unit
Low voltage marine cables
Shipboard cable
MarineMultiFlex BOQp 0,6/1 kV

Product group
Series
Type

Standardization
IEC 60092-350/-351/-353
Flame retardant
IEC 60332-1 / IEC 60332-3-22 Cat. A
Halogen free
IEC 60754-1
Conductor material
Cu, tinned
Conductor category
Class 5 = flexible
Shape of conductor
Round
Core insulation
Rubber (EPR)
Core identification
HD 308 S2
Construction outer shield EMC-screen consists of copper/PETtape and (CU) braiding
Material outer sheath
PUR (Polyurethane)
Colour outer sheath
Black
Nominal voltage U0
0.6
Nominal voltage U
1
Maximum conductor temperature
90
Operating temperature, flexible
-5 / 50
Operating temperature, fixed
-5 / 70

Partnumber
manufacturer
17349
3 x 50 mm

Shape
of
conductor
Round

Net
weight
3326

Bending
radius
after
installation
(mm)
258

17351

Round

5284

317

3 x 95 mm

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

kV
kV
C
C
C

Outer
diameter
approx.
(mm)
43

Tensile
load
(N)
2250

52,9

4275

Page 26

Marine & Offshore


MarineLine YZp FR 0,6/1 kV

Fire resistant low voltage power cables for power and lighting applications in all ship areas,
with reduced diameter and weight. High abrasion resistant sheath and easily strippable with ripcord.
Halogen-free and low-smoke, flame-retardant in fire conditions.

Characteristics

Properties Unit
Low voltage marine cables
Shipboard cable
MarineLine YZp FR 0,6/1 kV

Product group
Series
Type

Standardization
IEC 60092-350/-351/-353
Flame retardant
IEC 60332-1 / IEC 60332-3-22 Cat. A
Halogen free
IEC 60754-1
Insulation integrity in accordance with IEC 60331
Yes
Conductor material
Cu
Conductor category
Class 2 = stranded
Shape of conductor
Round
Core insulation
Mica + XLPE
Core identification
HD 308 S2
Material outer sheath Flame Retardant Halogen Free Polyolefin Compound
Colour outer sheath
Orange
Nominal voltage U0
0.6
Nominal voltage U
1
Maximum conductor temperature
90
Operating temperature, flexible
-20 / 70
Operating temperature, fixed
-40 / 70
Specification
See appendix

Construction
Partnumber
26080
26081
26082
26001
26002
16351
26003
26004
26006
16354
26009
26011
26013

G=Y/G
3 G 1,5 mm
4 G 1,5 mm
5 G 1,5 mm
2 x 1,5 mm
3 x 1,5 mm
3 x 1,5 mm
4 x 1,5 mm
5 x 1,5 mm
7 x 1,5 mm
7 x 1,5 mm
12 x 1,5 mm
19 x 1,5 mm
27 x 1,5 mm

Copyright (c) TKF, 06-03-2012

Shape
of
conductor
Round
Round
Round
Round
Round
Round
Round
Round
Round
Round
Round
Round
Round

Net
weight
(kg/km)
98
122
147
77
99
99
124
147
191
191
314
483
667

Bending
radius
after
installation
(mm)
36
39
43
34
36
36
39
43
47
47
63
78
91

Subject to technical alterations

kV
kV
C
C
C

Outer
diameter
approx.
(mm)
9
9,8
10,7
8,5
9
8,9
9,8
10,7
11,8
11,8
15,8
19,4
22,7

Tensile
load
(N)
68
90
113
45
68
68
90
113
158
158
270
428
608

Page 27

Marine & Offshore


MarineLine YZp FR 0,6/1 kV

Partnumber G=Y/G

Shape
of
conductor

Net
weight
(kg/km)

Bending
radius
after
installation
(mm)

Outer
diameter
approx.
(mm)

Tensile
load
(N)

16450

27 x 1,5 mm

Round

667

90

22,6

608

26084
26085
26086
26017
26018
26019
26020
26022

3 G 2,5 mm
4 G 2,5 mm
5 G 2,5 mm
2 x 2,5 mm
3 x 2,5 mm
4 x 2,5 mm
5 x 2,5 mm
7 x 2,5 mm

Round
Round
Round
Round
Round
Round
Round
Round

134
172
212
104
135
172
211
269

41
46
50
39
41
46
50
54

10,3
11,4
12,5
9,7
10,3
11,4
12,5
13,6

113
150
188
75
113
150
188
263

26024
26025
26026

2 x 4 mm
3 x 4 mm
4 x 4 mm

Round
Round
Round

137
181
237

42
43
48

10,5
10,7
11,9

120
180
240

26028
26029
26030

2 x 6 mm
3 x 6 mm
4 x 6 mm

Round
Round
Round

190
258
339

51
54
60

12,8
13,6
15,1

180
270
360

26032
26033
26034

2 x 10 mm
3 x 10 mm
4 x 10 mm

Round
Round
Round

287
390
510

56
59
65

13,9
14,8
16,2

300
450
600

26036
26037
26038

2 x 16 mm
3 x 16 mm
4 x 16 mm

Round
Round
Round

404
575
748

63
68
75

15,8
17
18,7

480
720
960

26041
26042

3 x 25 mm
4 x 25 mm

Round
Round

907
1196

84
93

21
23,3

1125
1500

26063

1 x 150 mm

Round

1534

86

21,5

2250

Construction

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

Page 28

Marine & Offshore


MarineLine YZp X-FR 0,6/1 kV

Fire resistant low voltage power cables according to the new demanding IEC -60331 1/2 specifications
for power and lighting applications in all ship areas, with reduced diameter and weight. High abrasion
resistant sheath and easily strippable with ripcord.
Halogen-free and low-smoke, flame-retardant in fire conditions.

Characteristics

Properties Unit
Low voltage marine cables
Shipboard cable

Product group
Series

Type
MarineLine YZp X-FR 0,6/1 kV
Standardization
IEC 60092-350/-351/-353
Flame retardant
IEC 60332-1 / IEC 60332-3-22 Cat. A
Halogen free
IEC 60754-1
Insulation integrity in accordance with IEC 60331
Yes
Conductor material
Cu
Conductor category
Class 2 = stranded
Shape of conductor
Article dependant, see detail sheet
Core insulation
Mica + XLHFFR
Core identification
HD 308 S2
Material outer sheath Flame Retardant Halogen Free Polyolefin Compound
Colour outer sheath
Orange
Nominal voltage U0
0.6
Nominal voltage U
1
Maximum conductor temperature
90
Operating temperature, flexible
-20 / 70
Operating temperature, fixed
-40 / 70
Specification
See appendix

Construction
Partnumber
27080
27081
27082
27083
27000
27001
27002
27003
27004
27005
27006
27007

G=Y/G
3 G 1,5 mm
4 G 1,5 mm
5 G 1,5 mm
7 G 1,5 mm
1 x 1,5 mm
2 x 1,5 mm
3 x 1,5 mm
4 x 1,5 mm
5 x 1,5 mm
6 x 1,5 mm
7 x 1,5 mm
8 x 1,5 mm

Copyright (c) TKF, 06-03-2012

Shape
of
conductor
Round
Round
Round
Round
Round
Round
Round
Round
Round
Round
Round
Round

Net
weight
(kg/km)
128
165
200
263
48
99
128
162
202
240
256
292

Bending
radius
after
installation
(mm)
42
47
51
56
23
40
42
46
51
56
56
52

Subject to technical alterations

kV
kV
C
C
C

Outer
diameter
approx.
(mm)
10,5
11,7
12,8
14,1
5,8
9,9
10,5
11,5
12,8
13,9
13,9
13

Tensile
load
(N)
68
90
113
158
23
45
68
90
113
135
158
180

Page 29

Marine & Offshore


MarineLine YZp X-FR 0,6/1 kV

Partnumber G=Y/G

Shape
of
conductor

Net
weight
(kg/km)

Bending
radius
after
installation
(mm)

Outer
diameter
approx.
(mm)

Tensile
load
(N)

27008
27009
27010
27011
27012
27013
27014
27015

10 x 1,5 mm
12 x 1,5 mm
16 x 1,5 mm
19 x 1,5 mm
24 x 1,5 mm
27 x 1,5 mm
30 x 1,5 mm
37 x 1,5 mm

Round
Round
Round
Round
Round
Round
Round
Round

376
430
524
664
860
899
989
1205

63
59
68
73
103
110
113
125

15,7
14,8
16,9
18,2
25,8
27,4
28,3
31,2

225
270
360
428
540
608
675
833

27084
27085
27086
27087
27016
27017
27018
27019
27020
27021
27022

3 G 2,5 mm
4 G 2,5 mm
5 G 2,5 mm
7 G 2,5 mm
1 x 2,5 mm
2 x 2,5 mm
3 x 2,5 mm
4 x 2,5 mm
5 x 2,5 mm
6 x 2,5 mm
7 x 2,5 mm

Round
Round
Round
Round
Round
Round
Round
Round
Round
Round
Round

170
219
271
339
61
125
166
216
264
312
339

38
51
46
61
25
44
46
51
56
61
61

9,5
12,8
11,6
15,3
6,3
10,9
11,5
12,8
14,1
15,3
15,3

113
150
188
263
38
75
113
150
188
225
263

27088
27089
27023
27024
27025
27026

3 G 4 mm
4 G 4 mm
1 x 4 mm
2 x 4 mm
3 x 4 mm
4 x 4 mm

Round
Round
Round
Round
Round
Round

230
291
81
165
228
292

51
56
27
48
51
56

12,8
14
6,8
11,9
12,8
14

180
240
60
120
180
240

27090
27091
27027
27028
27029
27030

3 G 6 mm
4 G 6 mm
1 x 6 mm
2 x 6 mm
3 x 6 mm
4 x 6 mm

Round
Round
Round
Round
Round
Round

300
396
105
220
300
394

57
62
30
53
56
62

14,2
15,6
7,4
13,2
14
15,6

270
360
90
180
270
360

27092
27093
27031
27032
27033
27034

3 G 10 mm
4 G 10 mm
1 x 10 mm
2 x 10 mm
3 x 10 mm
4 x 10 mm

Round
Round
Round
Round
Round
Round

436
566
148
308
436
566

63
70
32
59
63
70

15,8
17,4
8,1
14,7
15,8
17,4

450
600
150
300
450
600

27094
27095
27035
27036
27037
27038

3 G 16 mm
4 G 16 mm
1 x 16 mm
2 x 16 mm
3 x 16 mm
4 x 16 mm

Round
Round
Round
Round
Round
Round

640
827
217
450
640
835

74
80
38
69
74
81

18,4
20,1
9,4
17,2
18,4
20,3

720
960
240
480
720
960

Construction

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

Page 30

Marine & Offshore


MarineLine YZp X-FR 0,6/1 kV

Partnumber G=Y/G

Shape
of
conductor

Net
weight
(kg/km)

Bending
radius
after
installation
(mm)

Outer
diameter
approx.
(mm)

Tensile
load
(N)

27039
27040
27041
27042

1 x 25 mm
2 x 25 mm
3 x 25 mm
4 x 25 mm

Round
Round
Round
Round

323
678
972
1281

45
84
90
100

11,2
20,9
22,4
24,9

375
750
1125
1500

27043
27044
27045
27046

1 x 35 mm
2 x 35 mm
3 x 35 mm
4 x 35 mm

Round
Round
Sector-shaped
Sector-shaped

446
930
1310
1735

49
92
87
101

12,3
22,9
21,7
25,3

525
1050
1575
2100

27047
27048
27049
27050

1 x 50 mm
2 x 50 mm
3 x 50 mm
4 x 50 mm

Round
Round
Sector-shaped
Sector-shaped

551
1175
1730
2300

56
109
98
113

14,1
27,3
24,4
28,2

750
1500
2250
3000

27051
27053
27054

1 x 70 mm
3 x 70 mm
4 x 70 mm

Round
Sector-shaped
Sector-shaped

764
2392
3135

64
113
131

16
28,2
32,7

1050
3150
4200

27055
27057
27058

1 x 95 mm
3 x 95 mm
4 x 95 mm

Round
Sector-shaped
Sector-shaped

1031
3202
4258

73
126
147

18,3
31,5
36,8

1425
4275
5700

27059
27061
27062

1 x 120 mm
3 x 120 mm
4 x 120 mm

Round
Sector-shaped
Sector-shaped

1292
3924
5368

80
140
164

19,9
34,9
40,9

1800
5400
7200

27063
27065
27066

1 x 150 mm
3 x 150 mm
4 x 150 mm

Round
Sector-shaped
Sector-shaped

1566
4937
6481

88
153
182

22
38,2
45,4

2250
6750
9000

27067
27069
27070

1 x 185 mm
3 x 185 mm
4 x 185 mm

Round
Sector-shaped
Sector-shaped

1942
6081
8182

99
171
196

24,7
42,7
49

2775
8325
11100

27071

1 x 240 mm

Round

2501

109

27,3

3600

27075

1 x 300 mm

Round

3021

123

30,8

4500

Construction

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

Page 31

Marine & Offshore


MarineLine YOZp FR 0,6/1 kV

Fire resistant armoured, lightweight, reduced diameter low voltage cables for power and lighting
applications in all ship areas where extra mechanical and EMC protection is needed.
The sheath material has excellent abrasion resistance properties and can be stripped easily with
the ripcord.

Characteristics

Properties Unit
Low voltage marine cables
Shipboard cable

Product group
Series

Type
MarineLine YOZp FR 0,6/1 kV
Standardization
IEC 60092-350/-351/-353
Flame retardant
IEC 60332-1 / IEC 60332-3-22 Cat. A
Halogen free
IEC 60754-1
Insulation integrity in accordance with IEC 60331
Yes
Conductor material
Cu
Conductor category
Class 2 = stranded
Shape of conductor
Article dependant, see detail sheet
Core insulation
Mica + XLPE
Core identification
HD 308 S2
Construction outer shield
Tinned copper braiding
Material outer sheath Flame Retardant Halogen Free Polyolefin Compound
Colour outer sheath
Orange
Nominal voltage U0
0.6
Nominal voltage U
1
Maximum conductor temperature
90
Operating temperature, flexible
-20 / 70
Operating temperature, fixed
-40 / 70
Specification
See appendix

Construction
Partnumber
26180
26181
26182
16382
26101
26102
16383
26104
26105
26106
16386

G=Y/G
3 G 1,5 mm
4 G 1,5 mm
5 G 1,5 mm
2 x 1,5 mm
2 x 1,5 mm
3 x 1,5 mm
3 x 1,5 mm
5 x 1,5 mm
6 x 1,5 mm
7 x 1,5 mm
7 x 1,5 mm

Copyright (c) TKF, 06-03-2012

Shape
of
conductor
Round
Round
Round
Round
Round
Round
Round
Round
Round
Round
Round

Net
weight
(kg/km)
176
167
205
115
115
141
141
205
237
248
248

Bending
radius
after
installation
(mm)
40
43
47
38
38
40
39
47
51
51
50

Subject to technical alterations

kV
kV
C
C
C

Outer
diameter
approx.
(mm)
9,9
10,7
11,8
9,4
9,4
9,9
9,8
11,8
12,7
12,7
12,6

Tensile
load
(N)
68
90
113
45
45
68
68
113
135
158
158

Page 32

Marine & Offshore


MarineLine YOZp FR 0,6/1 kV

Partnumber G=Y/G

Shape
of
conductor

Net
weight
(kg/km)

Bending
radius
after
installation
(mm)

Outer
diameter
approx.
(mm)

Tensile
load
(N)

16448
26109
26111
16449
16451
26113

12 x 1,5 mm
12 x 1,5 mm
19 x 1,5 mm
19 x 1,5 mm
27 x 1,5 mm
27 x 1,5 mm

Round
Round
Round
Round
Round
Round

440
440
633
633
833
833

68
68
83
82
96
96

17,1
17,1
20,7
20,6
23,9
24

270
270
428
428
608
608

26184
26185
26186
26143
26117
26118
16388
26119
26120
26121
26122

3 G 2,5 mm
4 G 2,5 mm
5 G 2,5 mm
5 G 2,5 mm
2 x 2,5 mm
3 x 2,5 mm
3 x 2,5 mm
4 x 2,5 mm
5 x 2,5 mm
6 x 2,5 mm
7 x 2,5 mm

Round
Round
Round
Round
Round
Round
Round
Round
Round
Round
Round

189
225
271
271
149
188
191
225
271
363
381

46
49
54
54
42
46
45
49
54
60
60

11,4
12,3
13,4
13,4
10,6
11,4
11,3
12,3
13,4
15,1
15,1

113
150
188
188
75
113
113
150
188
225
263

26124
26125
26126

2 x 4 mm
3 x 4 mm
4 x 4 mm

Round
Round
Round

191
265
325

46
49
53

11,6
12,2
13,2

120
180
240

26128
26129
26130

2 x 6 mm
3 x 6 mm
4 x 6 mm

Round
Round
Round

250
360
444

56
59
66

13,9
14,7
16,6

180
270
360

26131
26132
26133
26134

1 x 10 mm
2 x 10 mm
3 x 10 mm
4 x 10 mm

Round
Round
Round
Round

174
385
496
634

35
61
64
71

8,7
15,2
16,1
17,7

150
300
450
600

26135
26136
26137
26138

1 x 16 mm
2 x 16 mm
3 x 16 mm
4 x 16 mm

Round
Round
Round
Round

238
527
696
903

39
69
73
81

9,7
17,3
18,3
20,2

240
480
720
960

26139
26140
26141
26142

1 x 25 mm
2 x 25 mm
3 x 25 mm
4 x 25 mm

Round
Round
Round
Round

356
779
1069
1380

46
84
90
99

11,6
21
22,5
24,8

375
750
1125
1500

26145
26146

3 x 35 mm
4 x 35 mm

Sector-shaped
Sector-shaped

1434
1788

174
198

21,7
24,7

1575
2100

26149
26150

3 x 50 mm
4 x 50 mm

Sector-shaped
Sector-shaped

1806
2379

192
222

24
27,7

2250
3000

26153
26154

3 x 70 mm
4 x 70 mm

Sector-shaped
Sector-shaped

2461
3201

224
252

28
31,5

3150
4200

Construction

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

Page 33

Marine & Offshore


MarineLine YOZp FR 0,6/1 kV

Partnumber G=Y/G

Shape
of
conductor

Net
weight
(kg/km)

Bending
radius
after
installation
(mm)

Outer
diameter
approx.
(mm)

Tensile
load
(N)

26157

3 x 95 mm

Sector-shaped

3378

266

33,3

4275

26161

3 x 120 mm

Sector-shaped

4113

278

34,7

5400

26163

1 x 150 mm

Round

1703

92

23,1

2250

Construction

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

Page 34

Marine & Offshore


MarineLine YOZp X-FR 0,6/1 kV

Fire resistant according to new IEC 60331-1/2 (2009) specifications armoured, lightweight,
reduced diameter low voltage cables for power and lighting applications in all ship areas where
extra mechanical and EMC protection is needed.
The sheath material has excellent abrasion resistance properties and can be stripped easily
with the ripcord.

Characteristics

Properties Unit
Low voltage marine cables

Product group

Series
Shipboard cable
Type
MarineLine YOZp X-FR 0,6/1 kV
Standardization
IEC 60092-350/-351/-353
Flame retardant
IEC 60332-1 / IEC 60332-3-22 Cat. A
Halogen free
IEC 60754-1
Insulation integrity in accordance with IEC 60331
Yes
Conductor material
Cu
Conductor category
Class 2 = stranded
Shape of conductor
Article dependant, see detail sheet
Core insulation
Mica + XLHFFR
Core identification
HD 308 S2
Construction outer shield
Tinned copper braiding
Material outer sheath Flame Retardant Halogen Free Polyolefin Compound
Colour outer sheath
Orange
Nominal voltage U0
0.6
Nominal voltage U
1
Maximum conductor temperature
90
Operating temperature, flexible
-20 / 70
Operating temperature, fixed
-40 / 70
Specification
See appendix

Construction
Partnumber
27180
27181
27182
27183
27100
27101
27102
27103
27104
27105

G=Y/G
3 G 1,5 mm
4 G 1,5 mm
5 G 1,5 mm
7 G 1,5 mm
1 x 1,5 mm
2 x 1,5 mm
3 x 1,5 mm
4 x 1,5 mm
5 x 1,5 mm
6 x 1,5 mm

Copyright (c) TKF, 06-03-2012

Shape
of
conductor
Round
Round
Round
Round
Round
Round
Round
Round
Round
Round

Net
weight
(kg/km)
176
224
262
324
76
147
178
224
262
309

Bending
radius
after
installation
(mm)
46
50
55
59
27
43
46
50
55
59

Subject to technical alterations

kV
kV
C
C
C

Outer
diameter
approx.
(mm)
11,4
12,6
13,7
14,8
6,7
10,8
11,4
12,6
13,7
14,8

Tensile
load
(N)
68
90
113
158
23
45
68
90
113
135

Page 35

Marine & Offshore


MarineLine YOZp X-FR 0,6/1 kV

Partnumber G=Y/G

Shape
of
conductor

Net
weight
(kg/km)

Bending
radius
after
installation
(mm)

Outer
diameter
approx.
(mm)

Tensile
load
(N)

27106
27107
27108
27109
27110
27111
27112
27113
27114
27115

7 x 1,5 mm
8 x 1,5 mm
10 x 1,5 mm
12 x 1,5 mm
16 x 1,5 mm
19 x 1,5 mm
24 x 1,5 mm
27 x 1,5 mm
30 x 1,5 mm
37 x 1,5 mm

Round
Round
Round
Round
Round
Round
Round
Round
Round
Round

323
433
509
576
732
819
1040
1117
1140
1466

59
68
78
80
90
97
108
114
118
131

14,8
16,9
19,4
20
22,6
24,3
26,9
28,5
29,4
32,7

158
180
225
270
360
428
540
608
675
833

27184
27185
27186
27187
27116
27117
27118
27119
27120

3 G 2,5 mm
4 G 2,5 mm
5 G 2,5 mm
7 G 2,5 mm
1 x 2,5 mm
2 x 2,5 mm
3 x 2,5 mm
4 x 2,5 mm
5 x 2,5 mm

Round
Round
Round
Round
Round
Round
Round
Round
Round

227
279
332
462
92
184
227
279
332

50
55
60
67
29
48
50
55
60

12,6
13,7
15
16,8
7,2
12
12,6
13,7
15

113
150
188
263
38
75
113
150
188

27188
27189
27123
27124
27125
27126

3 G 4 mm
4 G 4 mm
1 x 4 mm
2 x 4 mm
3 x 4 mm
4 x 4 mm

Round
Round
Round
Round
Round
Round

289
406
112
228
288
405

55
62
31
52
55
62

13,7
15,5
7,7
13
13,7
15,5

180
240
60
120
180
240

27190
27191
27127
27128
27129
27130

3 G 6 mm
4 G 6 mm
1 x 6 mm
2 x 6 mm
3 x 6 mm
4 x 6 mm

Round
Round
Round
Round
Round
Round

412
512
140
282
412
512

62
68
33
56
62
68

15,5
16,9
8,3
14,1
15,5
16,9

270
360
90
180
270
360

27192
27193
27131
27132
27133
27134

3 G 10 mm
4 G 10 mm
1 x 10 mm
2 x 10 mm
3 x 10 mm
4 x 10 mm

Round
Round
Round
Round
Round
Round

552
703
190
429
551
702

68
76
37
65
68
76

17,1
18,9
9,2
16,2
17,1
18,9

450
600
150
300
450
600

27194
27195
27135
27136
27137
27138

3 G 16 mm
4 G 16 mm
1 x 16 mm
2 x 16 mm
3 x 16 mm
4 x 16 mm

Round
Round
Round
Round
Round
Round

776
993
262
592
767
997

79
87
41
75
79
87

19,7
21,8
10,3
18,7
19,7
21,8

720
960
240
480
720
960

Construction

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

Page 36

Marine & Offshore


MarineLine YOZp X-FR 0,6/1 kV

Partnumber G=Y/G

Shape
of
conductor

Net
weight
(kg/km)

Bending
radius
after
installation
(mm)

Outer
diameter
approx.
(mm)

Tensile
load
(N)

27139
27140
27141
27142

1 x 25 mm
2 x 25 mm
3 x 25 mm
4 x 25 mm

Round
Round
Round
Round

381
852
1138
1471

49
90
95
105

12,3
22,4
23,7
26,2

375
750
1125
1500

27143
27144
27145
27146

1 x 35 mm
2 x 35 mm
3 x 35 mm
4 x 35 mm

Round
Round
Sector-shaped
Sector-shaped

510
1116
1488
1902

53
98
93
106

13,3
24,4
23,2
26,6

525
1050
1575
2100

27147
27148
27149
27150

1 x 50 mm
2 x 50 mm
3 x 50 mm
4 x 50 mm

Round
Round
Sector-shaped
Sector-shaped

666
1399
1920
2495

63
115
104
119

15,7
28,8
25,9
29,7

750
1500
2250
3000

27151
27153
27154

1 x 70 mm
3 x 70 mm
4 x 70 mm

Round
Sector-shaped
Sector-shaped

887
2610
3347

70
119
136

17,4
29,7
34

1050
3150
4200

27155
27157
27158

1 x 95 mm
3 x 95 mm
4 x 95 mm

Round
Sector-shaped
Sector-shaped

1169
3448
4598

79
131
155

19,7
32,8
38,7

1425
4275
5700

27159
27161
27162

1 x 120 mm
3 x 120 mm
4 x 120 mm

Round
Sector-shaped
Sector-shaped

1455
4280
5738

86
147
171

21,5
36,8
42,8

1800
5400
7200

27163
27165
27166

1 x 150 mm
3 x 150 mm
4 x 150 mm

Round
Sector-shaped
Sector-shaped

1732
5329
6914

94
160
188

23,4
40,1
47,1

2250
6750
9000

27167
27169
27170

1 x 185 mm
3 x 185 mm
4 x 185 mm

Round
Sector-shaped
Sector-shaped

2128
6533
8696

104
178
204

26,1
44,6
50,9

2775
8325
11100

27171

1 x 240 mm

Round

2706

115

28,7

3600

27175

1 x 300 mm

Round

3268

130

32,4

4500

Construction

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

Page 37

Marine & Offshore


MarineLine+ YZp X-FR 0,6/1 kV

Fire Resistant according to new IEC 60331-1/2 (2009) specifications low voltage power cables
for power and lighting applications in all ship areas, with extruded filler for heavy duty applications,
giving the cable optimal roundness and making sealing in cable transits easier.
High abrasion resistant sheath and easily strippable with the ripcord. Halogen-Free, low smoke,
flame retardant and fire resistant in fire conditions.
Characteristics

Properties Unit
Low voltage marine cables
Shipboard cable

Product group
Series

Type
MarineLine+ YZp X-FR 0,6/1 kV
Standardization
IEC 60092-350/-351/-353
Flame retardant
IEC 60332-1 / IEC 60332-3-22 Cat. A
Halogen free
IEC 60754-1
Insulation integrity in accordance with IEC 60331
Yes
Conductor material
Cu
Conductor category
Class 2 = stranded
Shape of conductor
Round
Core insulation
Mica + XLHFFR
Core identification
HD 308 S2
Material outer sheath Flame Retardant Halogen Free Polyolefin Compound
Colour outer sheath
Orange
Nominal voltage U0
0.6
Nominal voltage U
1
Maximum conductor temperature
90
Operating temperature, flexible
-20 / 70
Operating temperature, fixed
-40 / 70
Specification
See appendix

Construction
Partnumber
27280
27281
27282
27200
27201
27202
27203

G=Y/G
3 G 1,5 mm
4 G 1,5 mm
5 G 1,5 mm
2 x 1,5 mm
3 x 1,5 mm
4 x 1,5 mm
5 x 1,5 mm

Shape
of
conductor
Round
Round
Round
Round
Round
Round
Round

27283
27284
27285
27204

3 G 2,5 mm
4 G 2,5 mm
5 G 2,5 mm
2 x 2,5 mm

Round
Round
Round
Round

Copyright (c) TKF, 06-03-2012

Net
weight
(kg/km)
195
225
273
171
195
225
273

Bending
radius
after
installation
(mm)
46
50
55
43
46
50
55

241
290
348
212

50
55
60
47

Subject to technical alterations

kV
kV
C
C
C

Outer
diameter
approx.
(mm)
11,4
12,4
13,7
10,8
11,4
12,4
13,7

Tensile
load
(N)
68
90
113
45
68
90
113

12,4
13,7
15
11,8

113
150
188
75

Page 38

Marine & Offshore


MarineLine+ YZp X-FR 0,6/1 kV

Partnumber G=Y/G

Shape
of
conductor

Net
weight
(kg/km)

Bending
radius
after
installation
(mm)

Outer
diameter
approx.
(mm)

Tensile
load
(N)

27205
27206
27207

3 x 2,5 mm
4 x 2,5 mm
5 x 2,5 mm

Round
Round
Round

240
290
348

50
55
60

12,4
13,7
15

113
150
188

27286
27287
27288
27208
27209
27210

3 G 4 mm
4 G 4 mm
5 G 4 mm
2 x 4 mm
3 x 4 mm
4 x 4 mm

Round
Round
Round
Round
Round
Round

318
382
464
273
318
382

55
60
66
52
55
60

13,7
14,9
16,5
13
13,7
14,9

180
240
300
120
180
240

27289
27290
27291
27211
27212
27213

3 G 6 mm
4 G 6 mm
5 G 6 mm
2 x 6 mm
3 x 6 mm
4 x 6 mm

Round
Round
Round
Round
Round
Round

405
503
603
342
405
504

60
66
72
56
60
66

14,9
16,5
18,1
14,1
14,9
16,5

270
360
450
180
270
360

27292
27293
27294
27214
27215
27216

3 G 10 mm
4 G 10 mm
5 G 10 mm
2 x 10 mm
3 x 10 mm
4 x 10 mm

Round
Round
Round
Round
Round
Round

567
709
849
468
567
709

67
74
81
63
67
74

16,7
18,5
20,2
15,8
16,7
18,5

450
600
750
300
450
600

27295
27296
27297
27217
27218
27219

3 G 16 mm
4 G 16 mm
5 G 16 mm
2 x 16 mm
3 x 16 mm
4 x 16 mm

Round
Round
Round
Round
Round
Round

812
1009
1237
656
812
1009

77
85
94
72
77
85

19,3
21,2
23,5
18,1
19,3
21,2

720
960
1200
480
720
960

27220
27221
27222

2 x 25 mm
3 x 25 mm
4 x 25 mm

Round
Round
Round

990
1223
1532

88
93
103

22
23,3
25,8

750
1125
1500

Construction

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

Page 39

Marine & Offshore


MarineLine+ YOZp X-FR 0,6/1 kV

Tinned copper wire braided Fire Resistant according to new IEC 60331-1/2 (2009) specifications
low voltage power cables for power and lighting applications in all ship areas, with extruded filler
for heavy duty applications, giving the cable optimal roundness and making sealing in cable
transits easier. High abrasion resistant sheath and easily strippable with the ripcord.
Halogen-Free, low smoke, flame retardant and fire resistant in fire conditions.
Characteristics

Properties Unit
Low voltage marine cables
Shipboard cable

Product group
Series

Type
MarineLine+ YOZp X-FR 0,6/1 kV
Standardization
IEC 60092-350/-351/-353
Flame retardant
IEC 60332-1 / IEC 60332-3-22 Cat. A
Halogen free
IEC 60754-1
Insulation integrity in accordance with IEC 60331
Yes
Conductor material
Cu
Conductor category
Class 2 = stranded
Shape of conductor
Round
Core insulation
Mica + XLHFFR
Core identification
HD 308 S2
Construction outer shield
Tinned copper braiding
Material outer sheath Flame Retardant Halogen Free Polyolefin Compound
Colour outer sheath
Orange
Nominal voltage U0
0.6
Nominal voltage U
1
Maximum conductor temperature
90
Operating temperature, flexible
-20 / 70
Operating temperature, fixed
-40 / 70
Specification
See appendix

Construction
Partnumber
27380
27381
27382
27300
27301
27302
27303

G=Y/G
3 G 1,5 mm
4 G 1,5 mm
5 G 1,5 mm
2 x 1,5 mm
3 x 1,5 mm
4 x 1,5 mm
5 x 1,5 mm

Shape
of
conductor
Round
Round
Round
Round
Round
Round
Round

27383
27384
27385

3 G 2,5 mm
4 G 2,5 mm
5 G 2,5 mm

Round
Round
Round

Copyright (c) TKF, 06-03-2012

Net
weight
(kg/km)
283
333
374
255
283
333
384

Bending
radius
after
installation
(mm)
53
58
62
50
53
58
62

348
404
522

58
62
70

Subject to technical alterations

kV
kV
C
C
C

Outer
diameter
approx.
(mm)
13,2
14,4
15,5
12,6
13,2
14,4
15,5

Tensile
load
(N)
68
90
113
45
68
90
113

14,4
15,5
17,4

113
150
188

Page 40

Marine & Offshore


MarineLine+ YOZp X-FR 0,6/1 kV

Partnumber G=Y/G

Shape
of
conductor

Net
weight
(kg/km)

Bending
radius
after
installation
(mm)

Outer
diameter
approx.
(mm)

Tensile
load
(N)

27304
27305
27306
27307

2 x 2,5 mm
3 x 2,5 mm
4 x 2,5 mm
5 x 2,5 mm

Round
Round
Round
Round

367
348
404
522

55
58
62
70

13,8
14,4
15,5
17,4

75
113
150
188

27386
27387
27388
27308
27309
27310

3 G 4 mm
4 G 4 mm
5 G 4 mm
2 x 4 mm
3 x 4 mm
4 x 4 mm

Round
Round
Round
Round
Round
Round

494
555
642
377
494
555

62
69
75
59
62
69

15,5
17,3
18,7
14,8
15,5
17,3

180
240
300
120
180
240

27389
27390
27391
27311
27312
27313

3 G 6 mm
4 G 6 mm
5 G 6 mm
2 x 6 mm
3 x 6 mm
4 x 6 mm

Round
Round
Round
Round
Round
Round

578
682
812
454
578
682

69
75
82
64
69
75

17,3
18,7
20,5
15,9
17,3
18,7

270
360
450
180
270
360

27392
27393
27394
27314
27315
27316

3 G 10 mm
4 G 10 mm
5 G 10 mm
2 x 10 mm
3 x 10 mm
4 x 10 mm

Round
Round
Round
Round
Round
Round

756
909
1080
636
756
909

76
83
90
72
76
83

19,1
20,7
22,6
18
19,1
20,7

450
600
750
300
450
600

27395
27396
27397
27317
27318
27319

3 G 16 mm
4 G 16 mm
5 G 16 mm
2 x 16 mm
3 x 16 mm
4 x 16 mm

Round
Round
Round
Round
Round
Round

1015
1247
1497
863
1015
1247

86
94
104
82
86
94

21,5
23,6
25,9
20,5
21,5
23,6

720
960
1200
480
720
960

27320
27321
27322

2 x 25 mm
3 x 25 mm
4 x 25 mm

Round
Round
Round

1231
1482
1811

97
103
112

24,2
25,7
28

750
1125
1500

Construction

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

Page 41

Marine & Offshore


MarineFlex YZp X-FR 0,6/1 kV

The only flexible Fire Resistant cables! The extra flexibility ensures easy installation, also in tight
spaces such as emergency switchboards. The cables meet the heavy IEC 60331-2 fire resistancy test
for bigger cable sizes.
The sheath material has excellent abrasion resistance properties and can be stripped easily with
the ripcord. Halogen-free and low-smoke, flame-retardant in fire conditions.
Characteristics

Properties Unit
Low voltage marine cables
Shipboard cable

Product group
Series

Type
MarineFlex YZp X-FR 0,6/1 kV
Standardization
IEC 60092-350/-351/-353
Flame retardant
IEC 60332-1 / IEC 60332-3-22 Cat. A
Halogen free
IEC 60754-1
Insulation integrity in accordance with IEC 60331
Yes
Conductor material
Cu
Conductor category
Class 5 = flexible
Shape of conductor
Round
Core insulation
Mica + XLHFFR
Core identification
HD 308 S2
Material outer sheath Flame Retardant Halogen Free Polyolefin Compound
Colour outer sheath
Orange
Nominal voltage U0
0.6
Nominal voltage U
1
Maximum conductor temperature
90
Operating temperature, flexible
-20 / 70
Operating temperature, fixed
-40 / 70
Specification
See appendix

Construction

Net
weight
(kg/km)
411
1260
1550
1971

Bending
radius
after
installation
(mm)
52
100
107
119

kV
kV
C
C
C

Outer
diameter
approx.
(mm)
12,9
25
26,7
29,7

Tensile
load
(N)
525
1050
1575
2100

Partnumber
27230
27231
27232
27233

G=Y/G
1 x 35 mm
2 x 35 mm
3 x 35 mm
4 x 35 mm

Shape
of
conductor
Round
Round
Round
Round

27234
27235
27236
27237

1 x 50 mm
2 x 50 mm
3 x 50 mm
4 x 50 mm

Round
Round
Round
Round

545
1637
2045
2600

57
113
120
133

14,3
28,2
30
33,3

750
1500
2250
3000

27238
27240

1 x 70 mm
3 x 70 mm

Round
Round

745
2796

66
138

16,4
34,5

1050
3150

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

Page 42

Marine & Offshore


MarineFlex YZp X-FR 0,6/1 kV

Partnumber G=Y/G

Shape
of
conductor

Net
weight
(kg/km)

Bending
radius
after
installation
(mm)

Outer
diameter
approx.
(mm)

Tensile
load
(N)

27241

4 x 70 mm

Round

3561

153

38,3

4200

27242
27244
27245

1 x 95 mm
3 x 95 mm
4 x 95 mm

Round
Round
Round

969
3592
4593

74
154
171

18,4
38,5
42,8

1425
4275
5700

27246
27248
27249

1 x 120 mm
3 x 120 mm
4 x 120 mm

Round
Round
Round

1220
4624
5907

85
179
200

21,2
44,8
49,9

1800
5400
7200

27250
27252
27253

1 x 150 mm
3 x 150 mm
4 x 150 mm

Round
Round
Round

1491
5546
7126

90
189
211

22,5
47,3
52,8

2250
6750
9000

27254
27256
27257

1 x 185 mm
3 x 185 mm
4 x 185 mm

Round
Round
Round

1802
6694
8598

98
206
230

24,4
51,6
57,5

2775
8325
11100

27258
27260

1 x 240 mm
3 x 240 mm

Round
Round

2438
9246

118
251

29,6
62,7

3600
10800

27262

1 x 300 mm

Round

3061

123

30,7

4500

Construction

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

Page 43

Marine & Offshore


MarineFlex YOZp X-FR 0,6/1 kV

The only flexible Fire Resistant cables! The extra flexibility ensures easy installation, also in tight
spaces such as emergency switchboards. The cables meet the heavy IEC 60331-2 fire resistancy
test for bigger cable sizes. The sheath material has excellent abrasion resistance properties and
can be stripped easily with the ripcord. The tinned copper wire braid gives good EMI & mechanical
protection. Halogen-free and low-smoke, flame-retardant in fire conditions.
Characteristics

Properties Unit
Low voltage marine cables
Shipboard cable

Product group
Series

Type
MarineFlex YOZp X-FR 0,6/1 kV
Standardization
IEC 60092-350/-351/-353
Flame retardant
IEC 60332-1 / IEC 60332-3-22 Cat. A
Halogen free
IEC 60754-1
Insulation integrity in accordance with IEC 60331
Yes
Conductor material
Cu
Conductor category
Class 5 = flexible
Shape of conductor
Round
Core insulation
Mica + XLHFFR
Core identification
HD 308 S2
Material outer sheath Flame Retardant Halogen Free Polyolefin Compound
Colour outer sheath
Orange
Nominal voltage U0
0.6
Nominal voltage U
1
Maximum conductor temperature
90
Operating temperature, flexible
-20 / 70
Operating temperature, fixed
-40 / 70
Specification
See appendix

Construction

Net
weight
(kg/km)
475
1534
1835
2287

Bending
radius
after
installation
(mm)
56
110
116
128

kV
kV
C
C
C

Outer
diameter
approx.
(mm)
13,9
27,4
28,9
31,9

Tensile
load
(N)
525
1050
1575
2100

Partnumber
27330
27331
27332
27333

G=Y/G
1 x 35 mm
2 x 35 mm
3 x 35 mm
4 x 35 mm

Shape
of
conductor
Round
Round
Round
Round

27335
27336
27337

2 x 50 mm
3 x 50 mm
4 x 50 mm

Round
Round
Round

1945
2400
2927

122
130
143

30,4
32,4
35,7

1500
2250
3000

27338
27340
27341

1 x 70 mm
3 x 70 mm
4 x 70 mm

Round
Round
Round

876
3253
4085

72
148
164

18
37,1
41,1

1050
3150
4200

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

Page 44

Marine & Offshore


MarineFlex YOZp X-FR 0,6/1 kV

Partnumber G=Y/G

Shape
of
conductor

Net
weight
(kg/km)

Bending
radius
after
installation
(mm)

Outer
diameter
approx.
(mm)

Tensile
load
(N)

27342
27344
27345

1 x 95 mm
3 x 95 mm
4 x 95 mm

Round
Round
Round

1107
4275
5344

79
165
182

19,8
41,3
45,6

1425
4275
5700

27346
27348
27349

1 x 120 mm
3 x 120 mm
4 x 120 mm

Round
Round
Round

1398
5404
6750

91
190
210

22,8
47,6
52,5

1800
5400
7200

27350
27352
27353

1 x 150 mm
3 x 150 mm
4 x 150 mm

Round
Round
Round

1672
6435
8012

96
202
222

24
50,5
55,4

2250
6750
9000

27354
27356
27357

1 x 185 mm
3 x 185 mm
4 x 185 mm

Round
Round
Round

1990
7581
9568

103
217
240

25,8
54,2
60,1

2775
8325
11100

27358
27360

1 x 240 mm
3 x 240 mm

Round
Round

2666
10282

124
261

31
65,3

3600
10800

27362

1 x 300 mm

Round

3296

128

32,1

4500

Construction

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

Page 45

Marine & Offshore


MarinePower YOZmv 3,6/6 kV

The MarinePower cables are designed for medium voltage energy transport for fixed installation
in all ship areas. The special XLPE insulation has very good electrical properties and ensures
a high lifetime and availability of the installation. The tinned copper braid grants excellent
mechanical and EMC protection, and is compliant with the specifications of VFD manufacturers.
Characteristics

Properties Unit
Product group
Series
Type

Shipboard cable
MarinePower YOZmv 3,6/6 kV

Standardization
IEC 60092-354
Conductor material
Cu
Conductor category
Class 2 ss = stranded flexible
Conductor shield
Semiconductive XLPE
Core insulation
XLPE
Insulation shield Semiconductive XLPE, semicondictive tape and braiding
Armouring
Yes
Earthscreen construction
Tinned copper braiding
Material outer sheath Flame Retardant Halogen Free Polyolefin Compound
Colour outer sheath
Red
Halogen free
IEC 60754-1
Flame retardant
IEC 60332-1 / IEC 60332-3-22 Cat. A
Low smoke
IEC 61034-2
Nominal voltage U0
3.6
Nominal voltage U
6
Nominal voltage Umax
7.2
Max. conductor temperature
90
Operating temperature, flexible
-20 / 70
Operating temperature, fixed
-40 / 70
Specification
See appendix

kV
kV
kV
C
C
C

Partnumber Construction
33000
1 x 35 mm

Shape
of
conductor
Round

Net
weight
(kg/km)
711

Bending
radius
after
installation
(m)
0,23

33001

1 x 50 mm

Round

838

0,25

20,5

2500

33002

1 x 70 mm

Round

1055

0,27

22,3

3500

33003

1 x 95 mm

Round

1351

0,29

24

4750

33004

1 x 120 mm

Round

1668

0,31

25,8

6000

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

Outer
diameter
approx.
(mm)
19,4

Tensile
load
(N)
1750

Page 46

Marine & Offshore


MarinePower YOZmv 3,6/6 kV

Partnumber Construction

Shape
of
conductor

Net
weight
(kg/km)

Bending
radius
after
installation
(m)

Outer
diameter
approx.
(mm)

Tensile
load
(N)

33005

1 x 150 mm

Round

1935

0,33

27,5

7500

33006

1 x 185 mm

Round

2313

0,35

29,1

9250

33007

1 x 240 mm

Round

2941

0,39

32,1

12000

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

Page 47

Marine & Offshore


MarinePower YZOZmv 3,6/6 kV

The MarinePower cables are designed for medium voltage energy transport for fixed installation
in all ship areas. The special XLPE insulation has very good electrical properties and ensures
a high lifetime and availability of the installation. The tinned copper braid grants excellent mechanical
and EMC protection, and is compliant with the specifications of VFD manufacturers.
Characteristics

Properties
Product group
Series
Shipboard cable
Type
MarinePower YZOZmv 3,6/6 kV
Standardization
IEC 60092-354
Conductor material
Cu
Conductor category
Class 2 ss = stranded flexible
Conductor shield
Semiconductive XLPE
Core insulation
XLPE
Insulation shield Semicon-XLPE, semicon-swellable tape and copper tape
Armouring
Yes
Earthscreen construction
Tinned copper braiding
Material outer sheath Flame Retardant Halogen Free Polyolefin Compound
Colour outer sheath
Red
Halogen free
IEC 60754-1
Flame retardant
IEC 60332-1 / IEC 60332-3-22 Cat. A
Low smoke
IEC 61034-2
Nominal voltage U0
3.6
Nominal voltage U
6
Nominal voltage Umax
7.2
Max. conductor temperature
90
Operating temperature, flexible
-20 / 70
Operating temperature, fixed
-40 / 70
Specification
See appendix

Unit

kV
kV
kV
C
C
C

Partnumber Construction
33008
3 x 35 mm

Shape
of
conductor
Round

Net
weight
(kg/km)
2829

Bending
radius
after
installation
(m)
0,38

33009

3 x 50 mm

Round

3358

0,4

44,9

7500

33010

3 x 70 mm

Round

4074

0,44

48,9

10500

33011

3 x 95 mm

Round

5465

0,48

52,9

14250

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

Outer
diameter
approx.
(mm)
42,3

Tensile
load
(N)
5250

Page 48

Marine & Offshore


MarinePower YZOZmv 3,6/6 kV

Partnumber Construction

Shape
of
conductor

Net
weight
(kg/km)

Bending
radius
after
installation
(m)

Outer
diameter
approx.
(mm)

Tensile
load
(N)

33012

3 x 120 mm

Round

6043

0,51

56,8

18000

33013

3 x 150 mm

Round

7704

0,55

60,6

22500

33014

3 x 185 mm

Round

8651

0,58

64,4

27750

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

Page 49

Marine & Offshore


MarinePower YOZmv 6/10 kV

The MarinePower cables are designed for medium voltage energy transport for fixed installation
in all ship areas. The special XLPE insulation has very good electrical properties and ensures
a high lifetime and availability of the installation. The tinned copper braid grants excellent mechanical
and EMC protection, and is compliant with the specifications of VFD manufacturers.
Characteristics

Properties Unit
Product group
Series
Type

Shipboard cable
MarinePower YOZmv 6/10 kV

Standardization
IEC 60092-354
Conductor material
Cu
Conductor category
Class 2 ss = stranded flexible
Conductor shield
Semiconductive XLPE
Core insulation
XLPE
Insulation shield Semiconductive XLPE, semicondictive tape and braiding
Armouring
Yes
Earthscreen construction
Tinned copper braiding
Material outer sheath Flame Retardant Halogen Free Polyolefin Compound
Colour outer sheath
Red
Halogen free
IEC 60754-1
Flame retardant
IEC 60332-1 / IEC 60332-3-22 Cat. A
Low smoke
IEC 61034-2
Nominal voltage U0
6
Nominal voltage U
10
Nominal voltage Umax
12
Max. conductor temperature
90
Operating temperature, flexible
-20 / 70
Operating temperature, fixed
-40 / 70
Specification
See appendix

kV
kV
kV
C
C
C

Partnumber Construction
33100
1 x 35 mm

Shape
of
conductor
Round

Net
weight
(kg/km)
782

Bending
radius
after
installation
(m)
0,25

33101

1 x 50 mm

Round

933

0,27

22,5

2500

33102

1 x 70 mm

Round

1136

0,29

24,1

3500

33103

1 x 95 mm

Round

1447

0,31

26,1

4750

33104

1 x 120 mm

Round

1781

0,33

27,8

6000

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

Outer
diameter
approx.
(mm)
21,2

Tensile
load
(N)
1750

Page 50

Marine & Offshore


MarinePower YOZmv 6/10 kV

Partnumber Construction

Shape
of
conductor

Net
weight
(kg/km)

Bending
radius
after
installation
(m)

Outer
diameter
approx.
(mm)

Tensile
load
(N)

33105

1 x 150 mm

Round

2030

0,35

29,3

7500

33106

1 x 185 mm

Round

2429

0,37

31,1

9250

33107

1 x 240 mm

Round

3044

0,41

33,8

12000

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

Page 51

Marine & Offshore


MarinePower YZOZmv 6/10 kV

The MarinePower cables are designed for medium voltage energy transport for fixed installation
in all ship areas. The special XLPE insulation has very good electrical properties and ensures
a high lifetime and availability of the installation. The tinned copper braid grants excellent mechanical
and EMC protection, and is compliant with the specifications of VFD manufacturers.
Characteristics

Properties
Product group
Series
Shipboard cable
Type
MarinePower YZOZmv 6/10 kV
Standardization
IEC 60092-354
Conductor material
Cu
Conductor category
Class 2 ss = stranded flexible
Conductor shield
Semiconductive XLPE
Core insulation
XLPE
Insulation shield Semicon-XLPE, semicon-swellable tape and copper tape
Armouring
Yes
Earthscreen construction
Tinned copper braiding
Material outer sheath Flame Retardant Halogen Free Polyolefin Compound
Colour outer sheath
Red
Halogen free
IEC 60754-1
Flame retardant
IEC 60332-1 / IEC 60332-3-22 Cat. A
Low smoke
IEC 61034-2
Nominal voltage U0
6
Nominal voltage U
10
Nominal voltage Umax
12
Max. conductor temperature
90
Operating temperature, flexible
-20 / 70
Operating temperature, fixed
-40 / 70
Specification
See appendix

Unit

kV
kV
kV
C
C
C

Partnumber Construction
33117
3 x 25 mm

Shape
of
conductor
Round

Net
weight
(kg/km)
2770

Bending
radius
after
installation
(m)
0,4

33108

3 x 35 mm

Round

3141

0,42

46,7

5250

33109

3 x 50 mm

Round

3779

0,44

49,3

7500

33110

3 x 70 mm

Round

4733

0,48

53,1

10500

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

Outer
diameter
approx.
(mm)
44,7

Tensile
load
(N)
3750

Page 52

Marine & Offshore


MarinePower YZOZmv 6/10 kV

Partnumber Construction

Shape
of
conductor

Net
weight
(kg/km)

Bending
radius
after
installation
(m)

Outer
diameter
approx.
(mm)

Tensile
load
(N)

33111

3 x 95 mm

Round

5708

0,52

57,6

14250

33112

3 x 120 mm

Round

6922

0,55

61,2

18000

33113

3 x 150 mm

Round

7836

0,59

65

22500

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

Page 53

Marine & Offshore


MarinePowerFlex YZOZmv 6/10 kV

The MarinePowerFlex cables have a Class-5 flexible conductor, increasing the cable flexibility
and making installation easier in tight spaces.
The XLPE insulation has very good electrical properties and ensures a high lifetime and availability
of the installation. The tinned copper wire braids grants excellent mechanical and EMC protection,
and is compliant with the specifications of VFD manufacturers.
Characteristics

Properties
Product group
Series
Shipboard cable
Type
MarinePowerFlex YZOZmv 6/10 kV
Standardization
IEC 60092-354
Conductor material
Cu
Conductor category
Class 5 = flexible
Conductor shield
Semiconductive XLPE
Core insulation
XLPE
Insulation shield Semicon-XLPE, semicon-swellable tape and copper tape
Armouring
Yes
Earthscreen construction
Tinned copper braiding
Material outer sheath Flame Retardant Halogen Free Polyolefin Compound
Colour outer sheath
Red
Halogen free
IEC 60754-1
Flame retardant
IEC 60332-1 / IEC 60332-3-22 Cat. A
Low smoke
IEC 61034-2
Nominal voltage U0
6
Nominal voltage U
10
Nominal voltage Umax
12
Max. conductor temperature
90
Operating temperature, flexible
-20 / 70
Operating temperature, fixed
-40 / 70
Specification
See appendix

Unit

kV
kV
kV
C
C
C

Partnumber Construction
33129
3 x 50 mm

Shape
of
conductor
Round

Net
weight
(kg/km)
3843

Bending
radius
after
installation
(m)
0,48

33131

3 x 95 mm

Round

5656

0,55

61,4

14250

33132

3 x 120 mm

Round

6756

0,59

65,2

18000

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

Outer
diameter
approx.
(mm)
53,1

Tensile
load
(N)
7500

Page 54

Marine & Offshore


MarinePower MultiFlex YQOQmv 6/10 kV

The MarinePower Multiflex cables are designed for flexibility, and are used where continuous
bending is required, e.g. on cable chains in dredgers or in retractable Azipod drives.
The special sheathing material has very good resistance to chemicals and UV and is highly
abrasion resistant. Completely halogen-free, flame-retardant and low-smoke in fire conditions.
Characteristics

Properties Unit
Product group
Series
Type
Standardization
Conductor material
Conductor category
Conductor shield
Core insulation
Insulation shield
Laminated sheath
Core shield construction
Material inner sheath
Earthscreen construction
Material outer sheath
Colour outer sheath
Halogen free
Flame retardant
Low smoke
Nominal voltage U0
Nominal voltage U
Nominal voltage Umax
Max. conductor temperature

Shipboard cable
MarinePower MultiFlex YQOQmv 6/10 kV
IEC 60092-354
Cu
Class 5-Plus = Extra Flexible
Semiconductive XLPE with semiconductive tape
XLPE
Semiconductive XLPE with semiconductive tape
Yes
Copper round wire + copper tape counter spiral
PUR (Polyurethane)
Core screen and tinned copper braiding combination
PUR (Polyurethane)
Red
IEC 60754-1
IEC 60332-1 / IEC 60332-3-22 Cat. A
IEC 61034-2
6
10
12
90

Partnumber Construction
33189
3 x 50 mm

Shape
of
conductor
Round

Net
weight
(kg/km)
5285

Bending
radius
after
installation
(m)
0,35

33191

Round

7374

0,39

3 x 95 mm

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

kV
kV
kV
C

Outer
diameter
approx.
(mm)
57,5

Tensile
load
(N)
7500

65,4

14250

Page 55

Marine & Offshore


MarinePower YOZmv 8,7/15 kV

The MarinePower cables are designed for medium voltage energy transport for fixed installation
in all ship areas. The special XLPE insulation has very good electrical properties and ensures
a high lifetime and availability of the installation. The tinned copper braid grants excellent mechanical
and EMC protection, and is compliant with the specifications of VFD manufacturers.
Characteristics

Properties Unit
Product group
Series
Type

Shipboard cable
MarinePower YOZmv 8,7/15 kV

Standardization
IEC 60092-354
Conductor material
Cu
Conductor category
Class 2 ss = stranded flexible
Conductor shield
Semiconductive XLPE
Core insulation
XLPE
Insulation shield Semiconductive XLPE, semicondictive tape and braiding
Armouring
Yes
Earthscreen construction
Tinned copper braiding
Material outer sheath Flame Retardant Halogen Free Polyolefin Compound
Colour outer sheath
Red
Halogen free
IEC 60754-1
Flame retardant
IEC 60332-1 / IEC 60332-3-22 Cat. A
Low smoke
IEC 61034-2
Nominal voltage U0
8.7
Nominal voltage U
15
Nominal voltage Umax
17.5
Max. conductor temperature
90
Operating temperature, flexible
-20 / 70
Operating temperature, fixed
-40 / 70
Specification
See appendix

kV
kV
kV
C
C
C

Partnumber Construction
33200
1 x 35 mm

Shape
of
conductor
Round

Net
weight
(kg/km)
880

Bending
radius
after
installation
(m)
0,28

33201

1 x 50 mm

Round

1028

0,3

24,9

2500

33202

1 x 70 mm

Round

1245

0,32

26,5

3500

33203

1 x 95 mm

Round

1570

0,34

28,4

4750

33204

1 x 120 mm

Round

1894

0,36

30,2

6000

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

Outer
diameter
approx.
(mm)
23,6

Tensile
load
(N)
1750

Page 56

Marine & Offshore


MarinePower YOZmv 8,7/15 kV

Partnumber Construction

Shape
of
conductor

Net
weight
(kg/km)

Bending
radius
after
installation
(m)

Outer
diameter
approx.
(mm)

Tensile
load
(N)

33205

1 x 150 mm

Round

2162

0,38

31,7

7500

33206

1 x 185 mm

Round

2566

0,4

33,5

9250

33207

1 x 240 mm

Round

3279

0,44

36,5

12000

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

Page 57

Marine & Offshore


MarinePower YZOZmv 8,7/15 kV

The MarinePower cables are designed for medium voltage energy transport for fixed installation
in all ship areas. The special XLPE insulation has very good electrical properties and ensures
a high lifetime and availability of the installation. The tinned copper braid grants excellent mechanical
and EMC protection, and is compliant with the specifications of VFD manufacturers.
Characteristics

Properties
Product group
Series
Shipboard cable
Type
MarinePower YZOZmv 8,7/15 kV
Standardization
IEC 60092-354
Conductor material
Cu
Conductor category
Class 2 ss = stranded flexible
Conductor shield
Semiconductive XLPE
Core insulation
XLPE
Insulation shield Semicon-XLPE, semicon-swellable tape and copper tape
Armouring
Yes
Earthscreen construction
Tinned copper braiding
Material outer sheath Flame Retardant Halogen Free Polyolefin Compound
Colour outer sheath
Red
Halogen free
IEC 60754-1
Flame retardant
IEC 60332-1 / IEC 60332-3-22 Cat. A
Low smoke
IEC 61034-2
Nominal voltage U0
8.7
Nominal voltage U
15
Nominal voltage Umax
17.5
Max. conductor temperature
90
Operating temperature, flexible
-20 / 70
Operating temperature, fixed
-40 / 70
Specification
See appendix

Unit

kV
kV
kV
C
C
C

Partnumber Construction
33208
3 x 35 mm

Shape
of
conductor
Round

Net
weight
(kg/km)
3773

Bending
radius
after
installation
(m)
0,47

33209

3 x 50 mm

Round

4486

0,49

54,8

7500

33210

3 x 70 mm

Round

5182

0,53

58,6

10500

33211

3 x 95 mm

Round

6370

0,57

62,9

14250

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

Outer
diameter
approx.
(mm)
52,1

Tensile
load
(N)
5250

Page 58

Marine & Offshore


MarinePower YZOZmv 8,7/15 kV

Partnumber Construction

Shape
of
conductor

Net
weight
(kg/km)

Bending
radius
after
installation
(m)

Outer
diameter
approx.
(mm)

Tensile
load
(N)

33212

3 x 120 mm

Round

7468

0,6

66,7

18000

33213

3 x 150 mm

Round

8917

0,65

71,8

22500

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

Page 59

Marine & Offshore


MarinePower YOZmv 12/20 kV

The MarinePower cables are designed for medium voltage energy transport for fixed installation
in all ship areas. The special XLPE insulation has very good electrical properties and ensures
a high lifetime and availability of the installation. The tinned copper braid grants excellent mechanical
and EMC protection, and is compliant with the specifications of VFD manufacturers.
Characteristics

Properties Unit
Product group
Series
Type

Shipboard cable
MarinePower YOZmv 12/20 kV

Standardization
IEC 60092-354
Conductor material
Cu
Conductor category
Class 2 ss = stranded flexible
Conductor shield
Semiconductive XLPE
Core insulation
XLPE
Insulation shield Semiconductive XLPE, semicondictive tape and braiding
Armouring
Yes
Earthscreen construction
Tinned copper braiding
Material outer sheath Flame Retardant Halogen Free Polyolefin Compound
Colour outer sheath
Red
Halogen free
IEC 60754-1
Flame retardant
IEC 60332-1 / IEC 60332-3-22 Cat. A
Low smoke
IEC 61034-2
Nominal voltage U0
12
Nominal voltage U
20
Nominal voltage Umax
24
Max. conductor temperature
90
Operating temperature, flexible
-20 / 70
Operating temperature, fixed
-40 / 70
Specification
See appendix

kV
kV
kV
C
C
C

Partnumber Construction
33300
1 x 35 mm

Shape
of
conductor
Round

Net
weight
(kg/km)
981

Bending
radius
after
installation
(m)
0,31

33301

1 x 50 mm

Round

1117

0,32

26,9

2500

33302

1 x 70 mm

Round

1357

0,34

28,7

3500

33303

1 x 95 mm

Round

1691

0,37

30,6

4750

33304

1 x 120 mm

Round

2005

0,39

32,2

6000

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

Outer
diameter
approx.
(mm)
25,8

Tensile
load
(N)
1750

Page 60

Marine & Offshore


MarinePower YOZmv 12/20 kV

Partnumber Construction

Shape
of
conductor

Net
weight
(kg/km)

Bending
radius
after
installation
(m)

Outer
diameter
approx.
(mm)

Tensile
load
(N)

33305

1 x 150 mm

Round

2288

0,41

33,9

7500

33306

1 x 185 mm

Round

2789

0,43

36,1

9250

33307

1 x 240 mm

Round

3427

0,46

38,7

12000

33320

1 x 400 mm

Round

5203

0,69

45

20000

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

Page 61

Marine & Offshore


MarinePower YZOZmv 12/20 kV

The MarinePower cables are designed for medium voltage energy transport for fixed installation
in all ship areas. The special XLPE insulation has very good electrical properties and ensures
a high lifetime and availability of the installation. The tinned copper braid grants excellent mechanical
and EMC protection, and is compliant with the specifications of VFD manufacturers.
Characteristics

Properties
Product group
Series
Shipboard cable
Type
MarinePower YZOZmv 12/20 kV
Standardization
IEC 60092-354
Conductor material
Cu
Conductor category
Class 2 ss = stranded flexible
Conductor shield
Semiconductive XLPE
Core insulation
XLPE
Insulation shield Semicon-XLPE, semicon-swellable tape and copper tape
Armouring
Yes
Earthscreen construction
Tinned copper braiding
Material outer sheath Flame Retardant Halogen Free Polyolefin Compound
Colour outer sheath
Red
Halogen free
IEC 60754-1
Flame retardant
IEC 60332-1 / IEC 60332-3-22 Cat. A
Low smoke
IEC 61034-2
Nominal voltage U0
12
Nominal voltage U
20
Nominal voltage Umax
24
Max. conductor temperature
90
Operating temperature, flexible
-20 / 70
Operating temperature, fixed
-40 / 70
Specification
See appendix

Unit

kV
kV
kV
C
C
C

Partnumber Construction
33308
3 x 35 mm

Shape
of
conductor
Round

Net
weight
(kg/km)
4228

Bending
radius
after
installation
(m)
0,51

33309

3 x 50 mm

Round

4735

0,54

59,5

7500

33310

3 x 70 mm

Round

5729

0,57

63,5

10500

33311

3 x 95 mm

Round

6800

0,61

67,6

14250

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

Outer
diameter
approx.
(mm)
56,7

Tensile
load
(N)
5250

Page 62

Marine & Offshore


MarinePower YZOZmv 12/20 kV

Partnumber Construction

Shape
of
conductor

Net
weight
(kg/km)

Bending
radius
after
installation
(m)

Outer
diameter
approx.
(mm)

Tensile
load
(N)

33312

Round

7589

0,64

71,2

18000

3 x 120 mm

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

Page 63

Marine & Offshore


MarinePower YOZmv 18/30 kV

The MarinePower cables are designed for medium voltage energy transport for fixed installation
in all ship areas. The special XLPE insulation has very good electrical properties and ensures
a high lifetime and availability of the installation. The tinned copper braid grants excellent mechanical
and EMC protection, and is compliant with
the specifications of VFD manufacturers.
Characteristics

Properties Unit
Product group
Series
Type

Shipboard cable
MarinePower YOZmv 18/30 kV

Standardization
IEC 60092-354
Conductor material
Cu
Conductor category
Class 2 ss = stranded flexible
Conductor shield
Semiconductive XLPE
Core insulation
XLPE
Insulation shield Semiconductive XLPE, semicondictive tape and braiding
Armouring
Yes
Earthscreen construction
Tinned copper braiding
Material outer sheath Flame Retardant Halogen Free Polyolefin Compound
Colour outer sheath
Red
Halogen free
IEC 60754-1
Flame retardant
IEC 60332-1 / IEC 60332-3-22 Cat. A
Low smoke
IEC 61034-2
Nominal voltage U0
18
Nominal voltage U
30
Nominal voltage Umax
36
Max. conductor temperature
90
Operating temperature, flexible
-20 / 70
Operating temperature, fixed
-40 / 70
Specification
See appendix

kV
kV
kV
C
C
C

Partnumber Construction
33400
1 x 35 mm

Shape
of
conductor
Round

Net
weight
(kg/km)
1250

Bending
radius
after
installation
(m)
0,37

33401

1 x 50 mm

Round

1403

0,39

32,3

2500

33402

1 x 70 mm

Round

1652

0,41

34,1

3500

33403

1 x 95 mm

Round

2084

0,44

36,4

4750

33404

1 x 120 mm

Round

2442

0,46

38,2

6000

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

Outer
diameter
approx.
(mm)
31,2

Tensile
load
(N)
1750

Page 64

Marine & Offshore


MarinePower YOZmv 18/30 kV

Partnumber Construction

Shape
of
conductor

Net
weight
(kg/km)

Bending
radius
after
installation
(m)

Outer
diameter
approx.
(mm)

Tensile
load
(N)

33405

1 x 150 mm

Round

2735

0,48

39,7

7500

33406

1 x 185 mm

Round

3152

0,5

41,5

9250

33407

1 x 240 mm

Round

3825

0,53

44,1

12000

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

Page 65

Marine & Offshore


MarinePower YZOZmv 18/30 kV

The MarinePower cables are designed for medium voltage energy transport for fixed installation
in all ship areas. The special XLPE insulation has very good electrical properties and ensures
a high lifetime and availability of the installation. The tinned copper braid grants excellent mechanical
and EMC protection, and is compliant with the specifications of VFD manufacturers.
Characteristics

Properties
Product group
Series
Shipboard cable
Type
MarinePower YZOZmv 18/30 kV
Standardization
IEC 60092-354
Conductor material
Cu
Conductor category
Class 2 ss = stranded flexible
Conductor shield
Semiconductive XLPE
Core insulation
XLPE
Insulation shield Semicon-XLPE, semicon-swellable tape and copper tape
Armouring
Yes
Earthscreen construction
Tinned copper braiding
Material outer sheath Flame Retardant Halogen Free Polyolefin Compound
Colour outer sheath
Red
Halogen free
IEC 60754-1
Flame retardant
IEC 60332-1 / IEC 60332-3-22 Cat. A
Low smoke
IEC 61034-2
Nominal voltage U0
18
Nominal voltage U
30
Nominal voltage Umax
36
Max. conductor temperature
90
Operating temperature, flexible
-20 / 70
Operating temperature, fixed
-40 / 70
Specification
See appendix

Partnumber Construction
33408
3 x 35 mm

Shape
of
conductor
Round

Net
weight
(kg/km)
5566

Bending
radius
after
installation
(m)
0,62

33409

Round

6244

0,65

3 x 50 mm

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

Unit

kV
kV
kV
C
C
C

Outer
diameter
approx.
(mm)
69,1

Tensile
load
(N)
5250

71,9

7500

Page 66

Marine & Offshore


MarineCom YOZc 250 V

Control, instrumentation, tele-and data communication cables.


The tinned copper braided screen reduces Electro Magnetic Interferences (EMI) and grants
extra mechanical protection. The XLPE isolation and variable twist lengths of the pairs provide
perfect electrical properties and low capacitance for minimal signal loss.
The special ripcord provides easy stripping of the outer sheath.
Characteristics

Properties Unit
Communication marine cables
Shipboard cable
MarineCom YOZc 250 V

Product group
Series
Type

Standardization
IEC 60092-350/-351/-376
Flame retardant
IEC 60332-1 / IEC 60332-3-22 Cat. A
Conductor category
Class 2 = stranded
Stranding element
Pair
Core insulation
XLPE
Core identification
Numbers
Construction outer shield
Tinned copper braiding
Screen over stranding
Braiding
Material outer sheath Flame Retardant Halogen Free Polyolefin Compound
Colour outer sheath
Grey
Maximum conductor temperature
90 C
Operating temperature, flexible
-20 / 70 C
Operating temperature, fixed
-40 / 70 C
Specification
See appendix

Partnumber
16900
16915
16901
16902
16916
16903
16917
16904
16905
16918
16906
16907
16919
16908
16909
16920

Construction
1 x 2 x 0,5 mm
1 x 3 x 0,5 mm
1 x 4 x 0,5 mm
2 x 2 x 0,5 mm
2 x 3 x 0,5 mm
4 x 2 x 0,5 mm
4 x 3 x 0,5 mm
6 x 2 x 0,5 mm
7 x 2 x 0,5 mm
7 x 3 x 0,5 mm
8 x 2 x 0,5 mm
10 x 2 x 0,5 mm
10 x 3 x 0,5 mm
12 x 2 x 0,5 mm
14 x 2 x 0,5 mm
14 x 3 x 0,5 mm

Copyright (c) TKF, 06-03-2012

Conductor
category
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded

Net
weight
(kg/km)
63
70
86
106
126
150
183
203
204
274
233
278
367
315
351
472

Bending
radius
after
installation
(mm)
41
43
47
58
62
67
73
78
78
89
84
94
108
100
106
119

Subject to technical alterations

Outer
diameter
approx.
(mm)
6,8
7,1
7,8
9,6
10,3
11,1
12,1
13
13
14,9
14
15,7
18
16,6
17,6
19,9

Tensile
load
(N)
15
23
30
30
45
60
90
90
105
158
120
150
225
180
210
315

Page 67

Marine & Offshore


MarineCom YOZc 250 V

Partnumber Construction

Conductor
category

Net
weight
(kg/km)

Bending
radius
after
installation
(mm)

Outer
diameter
approx.
(mm)

Tensile
load
(N)

16910
16921
16911
16922
16912
16913
16914

19 x 2 x 0,5 mm
19 x 3 x 0,5 mm
24 x 2 x 0,5 mm
24 x 3 x 0,5 mm
27 x 2 x 0,5 mm
30 x 2 x 0,5 mm
37 x 2 x 0,5 mm

Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded

449
653
606
801
652
711
829

121
137
136
154
143
149
163

20,1
22,9
22,7
25,6
23,8
24,8
27,2

285
428
360
540
405
450
555

16271
16272
16273
16270
16923
16274
16924
16275
16276
16925
16288
16277
16926
16289
16278
16927
16279
16928
16280
16929
16283
16281
16282

1 x 2 x 0,75 mm
1 x 3 x 0,75 mm
1 x 4 x 0,75 mm
2 x 2 x 0,75 mm
2 x 3 x 0,75 mm
4 x 2 x 0,75 mm
4 x 3 x 0,75 mm
6 x 2 x 0,75 mm
7 x 2 x 0,75 mm
7 x 3 x 0,75 mm
8 x 2 x 0,75 mm
10 x 2 x 0,75 mm
10 x 3 x 0,75 mm
12 x 2 x 0,75 mm
14 x 2 x 0,75 mm
14 x 3 x 0,75 mm
19 x 2 x 0,75 mm
19 x 3 x 0,75 mm
24 x 2 x 0,75 mm
24 x 3 x 0,75 mm
27 x 2 x 0,75 mm
30 x 2 x 0,75 mm
37 x 2 x 0,75 mm

Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded

71
85
104
128
156
188
229
273
276
351
301
372
483
414
480
670
675
869
819
1070
879
970
1158

43
45
48
41
67
48
77
57
57
96
61
69
117
72
77
131
89
149
98
167
103
108
120

7,1
7,5
8
10,3
11,1
12
12,9
14,3
14,3
16
15,2
17,2
19,5
18,1
19,3
21,8
22,2
24,9
24,6
27,8
25,8
27
30,1

23
34
45
45
68
90
135
135
158
236
180
225
338
270
315
473
428
641
540
810
608
675
833

16930
16945
16931
16932
16946
16933
16947
16934
16935
16948
16936
16937
16949
16938
16939
16950
16940

1 x 2 x 1 mm
1 x 3 x 1 mm
1 x 4 x 1 mm
2 x 2 x 1 mm
2 x 3 x 1 mm
4 x 2 x 1 mm
4 x 3 x 1 mm
6 x 2 x 1 mm
7 x 2 x 1 mm
7 x 3 x 1 mm
8 x 2 x 1 mm
10 x 2 x 1 mm
10 x 3 x 1 mm
12 x 2 x 1 mm
14 x 2 x 1 mm
14 x 3 x 1 mm
19 x 2 x 1 mm

Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded

80
96
114
141
177
208
272
300
306
373
340
418
621
469
538
797
754

45
47
52
65
71
76
84
91
91
103
96
109
128
114
122
141
142

7,5
7,8
8,6
10,9
11,8
12,6
14
15,1
15,1
17,1
16
18,2
21,3
19
20,4
23,5
23,7

30
45
60
60
90
120
180
180
210
315
240
300
450
360
420
630
570

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

Page 68

Marine & Offshore


MarineCom YOZc 250 V

Partnumber Construction

Conductor
category

Net
weight
(kg/km)

Bending
radius
after
installation
(mm)

Outer
diameter
approx.
(mm)

Tensile
load
(N)

16951
16941
16952
16942
16943
16944

19 x 3 x 1 mm
24 x 2 x 1 mm
24 x 3 x 1 mm
27 x 2 x 1 mm
30 x 2 x 1 mm
37 x 2 x 1 mm

Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded

1023
914
1262
1008
1102
1304

161
158
179
166
174
190

26,9
26,3
29,8
27,6
29
31,7

855
720
1080
810
900
1110

16301
16316
16302
16303
16317
16304
16318
16305
16306
16319
16307
16308
16320
16309
16310
16321
16311
16322
16312
16323
16313
16314
16315

1 x 2 x 1,5 mm
1 x 3 x 1,5 mm
1 x 4 x 1,5 mm
2 x 2 x 1,5 mm
2 x 3 x 1,5 mm
4 x 2 x 1,5 mm
4 x 3 x 1,5 mm
6 x 2 x 1,5 mm
7 x 2 x 1,5 mm
7 x 3 x 1,5 mm
8 x 2 x 1,5 mm
10 x 2 x 1,5 mm
10 x 3 x 1,5 mm
12 x 2 x 1,5 mm
14 x 2 x 1,5 mm
14 x 3 x 1,5 mm
19 x 2 x 1,5 mm
19 x 3 x 1,5 mm
24 x 2 x 1,5 mm
24 x 3 x 1,5 mm
27 x 2 x 1,5 mm
30 x 2 x 1,5 mm
37 x 2 x 1,5 mm

Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded

100
127
153
187
238
284
367
413
427
583
480
577
872
731
824
1121
1090
1459
1300
1791
1434
1571
1885

51
55
61
77
83
89
98
107
109
123
115
124
153
139
148
168
171
193
190
215
199
209
230

8,5
9,1
10,1
12,8
13,9
14,9
16,3
17,9
18,1
20,5
19,2
20,6
25,5
23,2
24,7
28
28,5
32,1
31,6
35,8
33,2
34,9
38,3

45
68
90
90
135
180
270
270
315
473
360
450
675
540
630
945
855
1283
1080
1620
1215
1350
1665

16960
16975
16961
16962
16976
16963
16977
16964
16965
16978
16966
16967
16979
16968
16969
16980
16970
16981

1 x 2 x 2,5 mm
1 x 3 x 2,5 mm
1 x 4 x 2,5 mm
2 x 2 x 2,5 mm
2 x 3 x 2,5 mm
4 x 2 x 2,5 mm
4 x 3 x 2,5 mm
6 x 2 x 2,5 mm
7 x 2 x 2,5 mm
7 x 3 x 2,5 mm
8 x 2 x 2,5 mm
10 x 2 x 2,5 mm
10 x 3 x 2,5 mm
12 x 2 x 2,5 mm
14 x 2 x 2,5 mm
14 x 3 x 2,5 mm
19 x 2 x 2,5 mm
19 x 3 x 2,5 mm

Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded

133
165
211
250
315
374
510
559
504
868
718
882
1225
1003
1138
1591
1497
2083

58
61
68
87
94
100
111
122
122
142
133
152
174
158
169
193
194
221

9,6
10,1
11,3
14,5
15,6
16,7
18,5
20,3
20,3
23,6
22,2
25,3
29
26,4
28,1
32,1
32,4
36,8

75
113
150
150
225
300
450
450
525
788
600
750
1125
900
1050
1575
1425
2138

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

Page 69

Marine & Offshore


MarineCom YOZc 250 V

Partnumber Construction

Conductor
category

Net
weight
(kg/km)

Bending
radius
after
installation
(mm)

Outer
diameter
approx.
(mm)

Tensile
load
(N)

16971
16982
16972
16973
16974

Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded

1840
2586
2035
2240
2683

217
247
228
240
263

36,2
41,1
38
40
43,8

1800
2700
2025
2250
2775

24 x 2 x 2,5 mm
24 x 3 x 2,5 mm
27 x 2 x 2,5 mm
30 x 2 x 2,5 mm
37 x 2 x 2,5 mm

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

Page 70

Marine & Offshore


MarineCom YOZc X-FR 250 V

Fire resistant according to new IEC 60331-1/2 (2009) specifications, control, instrumentation,
tele-and data communication cables. The tinned copper braided screen reduces
Electro Magnetic Interferences (EMI) and grants extra mechanical protection.
The XLHFFR isolation and variable twist lengths of the pairs provide perfect electrical properties
and low capacitance for minimal signal loss.
The special ripcord provides easy stripping of the outer sheath.
Characteristics

Properties Unit
Communication marine cables

Product group

Series
Shipboard cable
Type
MarineCom YOZc X-FR 250 V
Standardization
IEC 60092-350/-351/-376
Flame retardant
IEC 60332-1 / IEC 60332-3-22 Cat. A
Conductor category
Class 2 = stranded
Stranding element
Pair
Core insulation
Mica + XLHFFR
Core identification
Numbers
Construction outer shield
Tinned copper braiding
Screen over stranding
Braiding
Material outer sheath Flame Retardant Halogen Free Polyolefin Compound
Colour outer sheath
Orange
Maximum conductor temperature
90 C
Operating temperature, flexible
-20 / 70 C
Operating temperature, fixed
-40 / 70 C
Specification
See appendix

Partnumber
26470
26485
26471
26520
26486
26472
26487
26473
26474
26488
26475
26476
26489
26477

Construction
1 x 2 x 0,5 mm
1 x 3 x 0,5 mm
1 x 4 x 0,5 mm
2 x 2 x 0,5 mm
2 x 3 x 0,5 mm
4 x 2 x 0,5 mm
4 x 3 x 0,5 mm
6 x 2 x 0,5 mm
7 x 2 x 0,5 mm
7 x 3 x 0,5 mm
8 x 2 x 0,5 mm
10 x 2 x 0,5 mm
10 x 3 x 0,5 mm
12 x 2 x 0,5 mm

Copyright (c) TKF, 06-03-2012

Conductor
category
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded

Net
weight
(kg/km)
82
94
119
144
176
240
302
339
339
449
382
456
613
515

Bending
radius
after
installation
(mm)
32
33
37
69
75
83
91
98
98
113
106
120
137
125

Subject to technical alterations

Outer
diameter
approx.
(mm)
7,9
8,2
9,3
11,5
12,5
13,8
15,2
16,4
16,4
18,8
17,6
20
22,8
20,8

Tensile
load
(N)
15
23
30
30
45
60
90
90
105
158
120
150
225
180

Page 71

Marine & Offshore


MarineCom YOZc X-FR 250 V

Partnumber Construction

Conductor
category

Net
weight
(kg/km)

Bending
radius
after
installation
(mm)

Outer
diameter
approx.
(mm)

Tensile
load
(N)

26478
26490
26479
26491
26480
26492
26481
26482
26483

14 x 2 x 0,5 mm
14 x 3 x 0,5 mm
19 x 2 x 0,5 mm
19 x 3 x 0,5 mm
24 x 2 x 0,5 mm
24 x 3 x 0,5 mm
27 x 2 x 0,5 mm
30 x 2 x 0,5 mm
37 x 2 x 0,5 mm

Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded

576
778
740
986
891
1196
965
1070
1268

134
152
153
173
169
192
178
187
205

22,3
25,3
25,5
28,8
28,2
32
29,6
31,2
34,2

210
315
285
428
360
540
405
450
555

26500
26515
26501
26502
26516
26503
26517
26504
26505
26518
26506
26507
26519
26508
26509
26521
26510
26522
26511
26523
26512
26513
26514

1 x 2 x 0,75 mm
1 x 3 x 0,75 mm
1 x 4 x 0,75 mm
2 x 2 x 0,75 mm
2 x 3 x 0,75 mm
4 x 2 x 0,75 mm
4 x 3 x 0,75 mm
6 x 2 x 0,75 mm
7 x 2 x 0,75 mm
7 x 3 x 0,75 mm
8 x 2 x 0,75 mm
10 x 2 x 0,75 mm
10 x 3 x 0,75 mm
12 x 2 x 0,75 mm
14 x 2 x 0,75 mm
14 x 3 x 0,75 mm
19 x 2 x 0,75 mm
19 x 3 x 0,75 mm
24 x 2 x 0,75 mm
24 x 3 x 0,75 mm
27 x 2 x 0,75 mm
30 x 2 x 0,75 mm
37 x 2 x 0,75 mm

Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded

91
107
137
165
231
245
349
356
366
539
404
549
729
631
710
936
898
1228
1087
1494
1214
1332
1574

33
33
38
73
81
86
96
103
103
121
109
126
145
133
142
161
161
185
179
205
189
199
217

8,2
8,2
9,5
12,2
13,5
14,3
16
17,1
17,1
20,1
18,1
21
24,2
22,2
23,6
26,8
26,9
30,8
29,8
34,2
31,5
33,2
36,2

23
34
45
45
68
90
135
135
158
236
180
225
338
270
315
473
428
641
540
810
608
675
833

26526
26541
26527
26528
26542
26543
26532
26533
26545
26534
26535
26546
26536
26547
26537

1 x 2 x 1 mm
1 x 3 x 1 mm
1 x 4 x 1 mm
2 x 2 x 1 mm
2 x 3 x 1 mm
4 x 3 x 1 mm
8 x 2 x 1 mm
10 x 2 x 1 mm
10 x 3 x 1 mm
12 x 2 x 1 mm
14 x 2 x 1 mm
14 x 3 x 1 mm
19 x 2 x 1 mm
19 x 3 x 1 mm
24 x 2 x 1 mm

Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded

106
124
152
215
268
406
516
637
852
711
802
1099
1036
1443
1259

36
37
41
80
88
103
120
136
156
142
151
173
175
199
193

8,9
9,3
10,2
13,4
14,6
17,2
20
22,7
26
23,7
25,2
28,8
29,1
33,2
32,2

30
45
60
60
90
180
240
300
450
360
420
630
570
855
720

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

Page 72

Marine & Offshore


MarineCom YOZc X-FR 250 V

Partnumber Construction

Conductor
category

Net
weight
(kg/km)

Bending
radius
after
installation
(mm)

Outer
diameter
approx.
(mm)

Tensile
load
(N)

26548
26538
26539
26540

24 x 3 x 1 mm
27 x 2 x 1 mm
30 x 2 x 1 mm
37 x 2 x 1 mm

Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded

1840
1398
1613
1917

223
205
216
238

37,2
34,1
36
39,6

1080
810
900
1110

26550
26551
26552
26566
26553
26567
26554
26568
26555
26556
26569
26557
26558
26570
26559
26571
26560
26572
26561
26562
26563

1 x 2 x 1,5 mm
1 x 4 x 1,5 mm
2 x 2 x 1,5 mm
2 x 3 x 1,5 mm
4 x 2 x 1,5 mm
4 x 3 x 1,5 mm
6 x 2 x 1,5 mm
7 x 3 x 1,5 mm
8 x 2 x 1,5 mm
10 x 2 x 1,5 mm
10 x 3 x 1,5 mm
12 x 2 x 1,5 mm
14 x 2 x 1,5 mm
14 x 3 x 1,5 mm
19 x 2 x 1,5 mm
19 x 3 x 1,5 mm
24 x 2 x 1,5 mm
24 x 3 x 1,5 mm
27 x 2 x 1,5 mm
30 x 2 x 1,5 mm
37 x 2 x 1,5 mm

Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded

127
192
274
337
405
531
552
812
677
821
1135
922
1058
1487
1370
2027
1769
2479
1961
2142
2580

39
45
91
98
106
118
126
146
135
154
179
161
173
199
197
232
223
257
235
246
272

9,7
11,3
15,1
16,3
17,6
19,6
21
24,4
22,5
25,7
29,8
26,8
28,8
33,2
32,9
38,6
37,1
42,8
39,2
41
45,3

45
90
90
135
180
270
270
473
360
450
675
540
630
945
855
1283
1080
1620
1215
1350
1665

26575
26565
26590
26576
26577
26591
26592
26593
26581
26582
26594
26583
26584
26595
26585
26596
26586
26597
26587
26588
26589

1 x 2 x 2,5 mm
1 x 3 x 2,5 mm
1 x 3 x 2,5 mm
1 x 4 x 2,5 mm
2 x 2 x 2,5 mm
2 x 3 x 2,5 mm
4 x 3 x 2,5 mm
7 x 3 x 2,5 mm
8 x 2 x 2,5 mm
10 x 2 x 2,5 mm
10 x 3 x 2,5 mm
12 x 2 x 2,5 mm
14 x 2 x 2,5 mm
14 x 3 x 2,5 mm
19 x 2 x 2,5 mm
19 x 3 x 2,5 mm
24 x 2 x 2,5 mm
24 x 3 x 2,5 mm
27 x 2 x 2,5 mm
30 x 2 x 2,5 mm
37 x 2 x 2,5 mm

Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded

157
202
202
250
344
430
688
1112
897
1091
1535
1267
1423
2095
1957
2746
2415
3398
2685
2955
3587

64
46
69
74
101
109
130
165
152
174
201
183
196
226
227
259
253
289
268
280
310

10,7
11,5
11,5
12,4
16,9
18,2
21,7
27,5
25,4
29
33,5
30,5
32,6
37,6
37,9
43,2
42,2
48,1
44,6
46,7
51,7

75
113
113
150
150
225
450
788
600
750
1125
900
1050
1575
1425
2138
1800
2700
2025
2250
2775

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

Page 73

Marine & Offshore


MarineCom YZafc 250 V

Special lightweight communication cables for use in yachts.


When no mechanical protection is needed, but screening is necessary these cables offer
a lightweight and small-diameter solution compared to braided cables.
The Alu-pet tape in combination with the tinned copper drainwire offers good EMI protection.
Characteristics

Properties Unit
Communication marine cables
Shipboard cable
MarineCom YZafc 250 V

Product group
Series
Type

Standardization
IEC 60092-350/-351/-376
Flame retardant
IEC 60332-1 / IEC 60332-3-22 Cat. A
Conductor category
Class 2 = stranded
Stranding element
Pair
Core insulation
XLPE
Core identification
Numbers
Screen over stranding
Alpet tape
Material outer sheath Flame Retardant Halogen Free Polyolefin Compound
Colour outer sheath
Grey
Maximum conductor temperature
90 C
Operating temperature, flexible
-20 / 70 C
Operating temperature, fixed
-40 / 70 C
Specification
See appendix

Partnumber
16690
16691
16692
16693
16694
16695
16696
16697
16698
16699
16700
16701
16702
16703
16704

Construction
1 x 2 x 0,5 mm
1 x 4 x 0,5 mm
2 x 2 x 0,5 mm
4 x 2 x 0,5 mm
6 x 2 x 0,5 mm
7 x 2 x 0,5 mm
8 x 2 x 0,5 mm
10 x 2 x 0,5 mm
12 x 2 x 0,5 mm
14 x 2 x 0,5 mm
19 x 2 x 0,5 mm
24 x 2 x 0,5 mm
27 x 2 x 0,5 mm
30 x 2 x 0,5 mm
37 x 2 x 0,5 mm

Conductor
category
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded

16708

1 x 2 x 0,75 mm

Class 2 = stranded

Copyright (c) TKF, 06-03-2012

Net
weight
(kg/km)
43
63
74
105
157
158
175
216
245
283
360
445
499
544
658

Bending
radius
after
installation
(mm)
49
57
71
82
98
98
105
120
126
135
154
171
182
190
209

Outer
diameter
approx.
(mm)
6,1
7,1
8,9
10,2
12,3
12,3
13,1
15
15,7
16,9
19,2
21,4
22,7
23,7
26,1

Tensile
load
(N)
15
30
30
60
90
105
120
150
180
210
285
360
405
450
555

51

51

6,4

23

Subject to technical alterations

Page 74

Marine & Offshore


MarineCom YZafc 250 V

Partnumber Construction

Conductor
category

Net
weight
(kg/km)

Bending
radius
after
installation
(mm)

Outer
diameter
approx.
(mm)

Tensile
load
(N)

16709
16710
16711
16712
16713
16714
16715
16716
16717
16718
16719
16722
16720
16721

1 x 4 x 0,75 mm
2 x 2 x 0,75 mm
4 x 2 x 0,75 mm
6 x 2 x 0,75 mm
7 x 2 x 0,75 mm
8 x 2 x 0,75 mm
10 x 2 x 0,75 mm
12 x 2 x 0,75 mm
14 x 2 x 0,75 mm
19 x 2 x 0,75 mm
24 x 2 x 0,75 mm
27 x 2 x 0,75 mm
30 x 2 x 0,75 mm
37 x 2 x 0,75 mm

Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded

93
92
144
211
214
244
302
346
392
514
628
684
773
935

58
77
90
107
107
116
130
139
147
169
189
200
209
230

7,3
9,6
11,3
13,4
13,4
14,5
16,3
17,4
18,4
21,1
23,6
25
26,1
28,8

45
45
90
135
158
180
225
270
315
428
540
608
675
833

16731
16730
16732
16733
16734
16735
16736
16737
16738
16739
16740
16741
16742
16743
16744

1 x 4 x 1 mm
2 x 1 x 1 mm
2 x 2 x 1 mm
4 x 2 x 1 mm
6 x 2 x 1 mm
7 x 2 x 1 mm
8 x 2 x 1 mm
10 x 2 x 1 mm
12 x 2 x 1 mm
14 x 2 x 1 mm
19 x 2 x 1 mm
24 x 2 x 1 mm
27 x 2 x 1 mm
30 x 2 x 1 mm
37 x 2 x 1 mm

Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded

89
57
102
161
236
243
278
344
395
449
591
745
823
901
1097

63
54
82
95
114
114
122
140
146
156
179
202
212
222
245

7,9
6,8
10,2
11,9
14,2
14,2
15,3
17,5
18,3
19,5
22,4
25,2
26,5
27,7
30,6

60
30
60
120
180
210
240
300
360
420
570
720
810
900
1110

16830
16831
16832
16833
16834
16835
16836
16837
16838
16839
16840
16841
16842
16843
16844

1 x 2 x 1,5 mm
1 x 4 x 1,5 mm
2 x 2 x 1,5 mm
4 x 2 x 1,5 mm
6 x 2 x 1,5 mm
7 x 2 x 1,5 mm
8 x 2 x 1,5 mm
10 x 2 x 1,5 mm
12 x 2 x 1,5 mm
14 x 2 x 1,5 mm
19 x 2 x 1,5 mm
24 x 2 x 1,5 mm
27 x 2 x 1,5 mm
30 x 2 x 1,5 mm
37 x 2 x 1,5 mm

Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded

74
123
141
221
337
350
397
493
568
658
872
1092
1209
1325
1613

62
75
97
112
136
138
146
168
175
189
218
244
257
269
296

7,8
9,4
12,1
14
17
17,2
18,3
21
21,9
23,6
27,2
30,5
32,1
33,6
37

45
90
90
180
270
315
360
450
540
630
855
1080
1215
1350
1665

16850
16851

1 x 2 x 2,5 mm
1 x 4 x 2,5 mm

Class 2 = stranded
Class 2 = stranded

99
167

70
83

8,7
10,4

75
150

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

Page 75

Marine & Offshore


MarineCom YZafc 250 V

Partnumber Construction

Conductor
category

Net
weight
(kg/km)

Bending
radius
after
installation
(mm)

Outer
diameter
approx.
(mm)

Tensile
load
(N)

16852
16853
16854
16855
16856
16857
16858
16859
16860
16861
16862
16863
16864

Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded

188
314
482
501
573
711
836
955
1263
1590
1766
1961
2392

109
128
155
155
167
192
202
216
249
279
294
310
342

13,6
16
19,4
19,4
20,9
24
25,3
27
31,1
34,9
36,7
38,7
42,7

150
300
450
525
600
750
900
1050
1425
1800
2025
2250
2775

2 x 2 x 2,5 mm
4 x 2 x 2,5 mm
6 x 2 x 2,5 mm
7 x 2 x 2,5 mm
8 x 2 x 2,5 mm
10 x 2 x 2,5 mm
12 x 2 x 2,5 mm
14 x 2 x 2,5 mm
19 x 2 x 2,5 mm
24 x 2 x 2,5 mm
27 x 2 x 2,5 mm
30 x 2 x 2,5 mm
37 x 2 x 2,5 mm

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

Page 76

Marine & Offshore


Marine2Com YOZ2c 250 V

The combination of the overall braid, individual and overall pair screening, and tinned copper
drain wires of the Marine2Com cables grants optimal protection against
electro Magnetic Interference (EMI). The XLPE isolation and variable twist lengths of
the pairs provides perfect electrical properties and low capacitance for minimal signal loss.
Characteristics

Properties Unit
Communication marine cables
Shipboard cable
Marine2Com YOZ2c 250 V

Product group
Series
Type

Standardization
IEC 60092-350/-351/-376
Flame retardant
IEC 60332-1 / IEC 60332-3-22 Cat. A
Conductor category
Class 2 = stranded
Stranding element
Pair
Core insulation
XLPE
Core identification
Numbers
Construction outer shield
Tinned copper braiding
Screen over stranding element
Alpet tape
Screen over stranding
Foil + braiding
Material outer sheath Flame Retardant Halogen Free Polyolefin Compound
Colour outer sheath
Grey
Maximum conductor temperature
90 C
Operating temperature, flexible
-20 / 70 C
Operating temperature, fixed
-40 / 70 C
Specification
See appendix

Partnumber
17223
17280
17224
17281
17225
17226
17282
17227
17228
17283
17229
17230
17284
17231
17285

Construction
2 x 2 x 0,5 mm
2 x 3 x 0,5 mm
4 x 2 x 0,5 mm
4 x 3 x 0,5 mm
6 x 2 x 0,5 mm
7 x 2 x 0,5 mm
7 x 3 x 0,5 mm
8 x 2 x 0,5 mm
10 x 2 x 0,5 mm
10 x 3 x 0,5 mm
12 x 2 x 0,5 mm
14 x 2 x 0,5 mm
14 x 3 x 0,5 mm
19 x 2 x 0,5 mm
19 x 3 x 0,5 mm

Copyright (c) TKF, 06-03-2012

Conductor
category
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded

Net
weight
(kg/km)
134
158
192
226
272
277
342
307
376
468
420
471
646
657
833

Bending
radius
after
installation
(mm)
82
89
95
103
114
114
127
120
137
155
142
151
174
176
198

Subject to technical alterations

Outer
diameter
approx.
(mm)
10,3
11,1
11,9
12,9
14,2
14,2
15,9
15
17,1
19,4
17,8
18,9
21,7
22
24,7

Tensile
load
(N)
30
45
60
90
90
105
158
120
150
225
180
210
315
285
428

Page 77

Marine & Offshore


Marine2Com YOZ2c 250 V

Partnumber Construction

Conductor
category

Net
weight
(kg/km)

Bending
radius
after
installation
(mm)

Outer
diameter
approx.
(mm)

Tensile
load
(N)

17232
17286
17233
17234
17235

24 x 2 x 0,5 mm
24 x 3 x 0,5 mm
27 x 2 x 0,5 mm
30 x 2 x 0,5 mm
37 x 2 x 0,5 mm

Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded

796
1010
890
958
1144

195
219
206
215
236

24,4
27,4
25,8
26,9
29,5

360
540
405
450
555

16290
17290
16291
17291
16292
16293
17292
17237
16294
17293
17238
16295
17294
16296
17295
16297
17296
17239
16298
16299

2 x 2 x 0,75 mm
2 x 3 x 0,75 mm
4 x 2 x 0,75 mm
4 x 3 x 0,75 mm
6 x 2 x 0,75 mm
7 x 2 x 0,75 mm
7 x 3 x 0,75 mm
8 x 2 x 0,75 mm
10 x 2 x 0,75 mm
10 x 3 x 0,75 mm
12 x 2 x 0,75 mm
14 x 2 x 0,75 mm
14 x 3 x 0,75 mm
19 x 2 x 0,75 mm
19 x 3 x 0,75 mm
24 x 2 x 0,75 mm
24 x 3 x 0,75 mm
27 x 2 x 0,75 mm
30 x 2 x 0,75 mm
37 x 2 x 0,75 mm

Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded

159
185
229
280
326
332
421
377
451
635
509
587
814
826
1041
1003
1283
1092
1203
1427

90
95
103
112
123
123
137
130
149
170
153
167
188
194
214
215
238
222
238
261

11,3
11,9
12,9
14
15,4
15,4
17,1
16,3
18,6
21,3
19,1
20,9
23,5
24,2
26,8
26,9
29,7
27,8
29,7
32,6

45
68
90
135
135
158
236
180
225
338
270
315
473
428
641
540
810
608
675
833

17243
17300
17244
17301
17245
17246
17242
17247
17248
17303
17249
17250
17304
17251
17305
17252
17256
17253
17254
17255

2 x 2 x 1 mm
2 x 3 x 1 mm
4 x 2 x 1 mm
4 x 3 x 1 mm
6 x 2 x 1 mm
7 x 2 x 1 mm
7 x 3 x 1 mm
8 x 2 x 1 mm
10 x 2 x 1 mm
10 x 3 x 1 mm
12 x 2 x 1 mm
14 x 2 x 1 mm
14 x 3 x 1 mm
19 x 2 x 1 mm
19 x 3 x 1 mm
24 x 2 x 1 mm
24 x 3 x 1 mm
27 x 2 x 1 mm
30 x 2 x 1 mm
37 x 2 x 1 mm

Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded

175
205
253
318
366
376
489
425
522
736
588
728
886
927
1210
1141
1401
1259
1363
1635

94
101
108
119
130
130
148
139
158
183
166
179
198
204
230
228
257
239
250
275

11,8
12,6
13,5
14,9
16,2
16,2
18,5
17,4
19,8
22,9
20,7
22,4
24,8
25,5
28,7
28,5
32,1
29,9
31,3
34,4

60
90
120
180
180
210
315
240
300
450
360
420
630
570
855
720
1080
810
900
1110

16333

2 x 2 x 1,5 mm

Class 2 = stranded

224

111

13,9

90

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

Page 78

Marine & Offshore


Marine2Com YOZ2c 250 V

Partnumber Construction

Conductor
category

Net
weight
(kg/km)

Bending
radius
after
installation
(mm)

Outer
diameter
approx.
(mm)

Tensile
load
(N)

17310
17311
16334
16336
17312
16337
16338
17317
16339
16340
17314
16341
17315
16342
17316
16343
16344
16345

2 x 3 x 1,5 mm
4 x 3 x 1,5 mm
6 x 2 x 1,5 mm
7 x 2 x 1,5 mm
7 x 3 x 1,5 mm
8 x 2 x 1,5 mm
10 x 2 x 1,5 mm
10 x 3 x 1,5 mm
12 x 2 x 1,5 mm
14 x 2 x 1,5 mm
14 x 3 x 1,5 mm
19 x 2 x 1,5 mm
19 x 3 x 1,5 mm
24 x 2 x 1,5 mm
24 x 3 x 1,5 mm
27 x 2 x 1,5 mm
30 x 2 x 1,5 mm
37 x 2 x 1,5 mm

Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded

271
427
486
514
728
569
756
998
1032
975
1291
1262
1661
1498
1960
1601
1754
856

118
141
154
155
179
165
192
218
200
214
242
246
276
274
310
288
302
336

14,8
17,6
19,2
19,4
22,4
20,6
24
27,3
25
26,8
30,2
30,7
34,5
34,2
38,7
36
37,8
42

135
270
270
315
473
360
450
675
540
630
945
855
1283
1080
1620
1215
1350
1665

17263
17320
17276
17321
17265
17266
17322
17267
17268
17323
17269
17270
17324
17271
17325
17272
17326
17273
17274
17275

2 x 2 x 2,5 mm
2 x 3 x 2,5 mm
4 x 2 x 2,5 mm
4 x 3 x 2,5 mm
6 x 2 x 2,5 mm
7 x 2 x 2,5 mm
7 x 3 x 2,5 mm
8 x 2 x 2,5 mm
10 x 2 x 2,5 mm
10 x 3 x 2,5 mm
12 x 2 x 2,5 mm
14 x 2 x 2,5 mm
14 x 3 x 2,5 mm
19 x 2 x 2,5 mm
19 x 3 x 2,5 mm
24 x 2 x 2,5 mm
24 x 3 x 2,5 mm
27 x 2 x 2,5 mm
30 x 2 x 2,5 mm
37 x 2 x 2,5 mm

Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded

291
358
452
586
714
751
987
834
1032
1363
1184
1342
1786
1729
2342
2055
2735
2214
2608
928

125
134
146
160
178
178
203
191
218
248
230
244
275
279
317
314
354
330
346
381

15,6
16,8
18,2
20
22,3
22,3
25,4
23,9
27,2
31
28,7
30,5
34,4
34,9
39,6
39,2
44,2
41,2
43,2
47,6

150
225
300
450
450
525
788
600
750
1125
900
1050
1575
1425
2138
1800
2700
2025
2250
2775

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

Page 79

Marine & Offshore


Marine2Com YZ2afc 250 V

Special lightweight individually pair screened communication cables for use in yachts.
When no mechanical protection is needed, but screening is necessary these cables offer
a lightweight and small-diameter alternative to heavy braided cables.
Individual + overall pair screen of Alu-pet tape with drain-wires gives very good EMI protection.
Characteristics

Properties Unit
Communication marine cables
Shipboard cable
Marine2Com YZ2afc 250 V

Product group
Series
Type

Standardization
IEC 60092-350/-351/-376
Flame retardant
IEC 60332-1 / IEC 60332-3-22 Cat. A
Conductor category
Class 2 = stranded
Stranding element
Pair
Core insulation
XLPE
Core identification
Numbers
Screen over stranding element
Alpet tape
Screen over stranding
Alpet tape
Material outer sheath Flame Retardant Halogen Free Polyolefin Compound
Colour outer sheath
Grey
Maximum conductor temperature
90 C
Operating temperature, flexible
-20 / 70 C
Operating temperature, fixed
-40 / 70 C
Specification
See appendix

Partnumber
16750
16751
16752
16753
16754
16755
16756
16757
16758
16759
16760
16761
16762

Construction
2 x 2 x 0,5 mm
4 x 2 x 0,5 mm
6 x 2 x 0,5 mm
7 x 2 x 0,5 mm
8 x 2 x 0,5 mm
10 x 2 x 0,5 mm
12 x 2 x 0,5 mm
14 x 2 x 0,5 mm
19 x 2 x 0,5 mm
24 x 2 x 0,5 mm
27 x 2 x 0,5 mm
30 x 2 x 0,5 mm
37 x 2 x 0,5 mm

Conductor
category
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded

16770
16771

2 x 2 x 0,75 mm
4 x 2 x 0,75 mm

Class 2 = stranded
Class 2 = stranded

Copyright (c) TKF, 06-03-2012

Net
weight
(kg/km)
91
136
205
211
242
292
343
388
510
633
699
776
930

Bending
radius
after
installation
(mm)
76
87
106
106
114
129
136
145
166
186
195
206
225

Outer
diameter
approx.
(mm)
9,5
10,9
13,2
13,2
14,2
16,1
17
18,1
20,8
23,2
24,4
25,7
28,1

Tensile
load
(N)
30
60
90
105
120
150
180
210
285
360
405
450
555

107
175

82
97

10,3
12,1

45
90

Subject to technical alterations

Page 80

Marine & Offshore


Marine2Com YZ2afc 250 V

Partnumber Construction

Conductor
category

Net
weight
(kg/km)

Bending
radius
after
installation
(mm)

Outer
diameter
approx.
(mm)

Tensile
load
(N)

16772
16773
16774
16775
16776
16777
16778
16779
16782
16780
16781

6 x 2 x 0,75 mm
7 x 2 x 0,75 mm
8 x 2 x 0,75 mm
10 x 2 x 0,75 mm
12 x 2 x 0,75 mm
14 x 2 x 0,75 mm
19 x 2 x 0,75 mm
24 x 2 x 0,75 mm
27 x 2 x 0,75 mm
30 x 2 x 0,75 mm
37 x 2 x 0,75 mm

Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded

262
268
299
370
426
497
652
809
895
988
1206

117
117
122
142
146
161
184
206
213
228
251

14,6
14,6
15,3
17,8
18,3
20,1
23
25,7
26,6
28,5
31,4

135
158
180
225
270
315
428
540
608
675
833

16790
16791
16792
16793
16794
16795
16796
16797
16798
16799
16800
16801
16802

2 x 2 x 1 mm
4 x 2 x 1 mm
6 x 2 x 1 mm
7 x 2 x 1 mm
8 x 2 x 1 mm
10 x 2 x 1 mm
12 x 2 x 1 mm
14 x 2 x 1 mm
19 x 2 x 1 mm
24 x 2 x 1 mm
27 x 2 x 1 mm
30 x 2 x 1 mm
37 x 2 x 1 mm

Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded

119
194
295
305
341
424
498
567
748
930
1044
1144
1394

86
102
123
123
131
150
159
170
194
217
230
241
266

10,8
12,8
15,4
15,4
16,4
18,8
19,9
21,2
24,3
27,1
28,7
30,1
33,2

60
120
180
210
240
300
360
420
570
720
810
900
1110

16810
16811
16812
16813
16814
16815
16816
16817
16818
16820
16821
16822

2 x 2 x 1,5 mm
4 x 2 x 1,5 mm
6 x 2 x 1,5 mm
7 x 2 x 1,5 mm
8 x 2 x 1,5 mm
10 x 2 x 1,5 mm
12 x 2 x 1,5 mm
14 x 2 x 1,5 mm
19 x 2 x 1,5 mm
27 x 2 x 1,5 mm
30 x 2 x 1,5 mm
37 x 2 x 1,5 mm

Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded

161
267
404
421
478
593
685
782
1048
1478
1600
1949

103
122
147
147
158
182
190
203
236
278
291
322

12,9
15,2
18,4
18,4
19,8
22,8
23,8
25,4
29,5
34,8
36,4
40,2

90
180
270
315
360
450
540
630
855
1215
1350
1665

16870
16871
16872
16873
16874
16875
16876
16877
16879
16880

2 x 2 x 2,5 mm
4 x 2 x 2,5 mm
6 x 2 x 2,5 mm
7 x 2 x 2,5 mm
8 x 2 x 2,5 mm
10 x 2 x 2,5 mm
12 x 2 x 2,5 mm
14 x 2 x 2,5 mm
24 x 2 x 2,5 mm
27 x 2 x 2,5 mm

Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded

221
361
552
591
663
837
972
1126
1884
2092

118
138
169
169
180
208
218
234
302
318

14,8
17,2
21,1
21,1
22,5
26
27,3
29,3
37,8
39,8

150
300
450
525
600
750
900
1050
1800
2025

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

Page 81

Marine & Offshore


Marine2Com YZ2afc 250 V

Partnumber Construction

Conductor
category

Net
weight
(kg/km)

Bending
radius
after
installation
(mm)

Outer
diameter
approx.
(mm)

Tensile
load
(N)

16881
16882

Class 2 = stranded
Class 2 = stranded

2306
2811

336
370

42
46,3

2250
2775

30 x 2 x 2,5 mm
37 x 2 x 2,5 mm

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

Page 82

Marine & Offshore


Marine2Com YOZ2c X-FR 250 V

Fire resistant according to new IEC 60331-1/2 (2009) specifications, control, instrumentation,
tele-and data communication cables. The combination of the overall braid, individual
and overall pair screening, and tinned copper drain wires of the Marine2Com cables grants optimal
protection against electro Magnetic Interference (EMI).
The XLHFFR isolation and variable twist lengths of the pairs provide perfect electrical properties
and low capacitance for minimal signal loss.
The special ripcord provides easy stripping of the outer sheath.
Characteristics

Properties
Product group
Communication marine cables
Series
Shipboard cable
Type
Marine2Com YOZ2c X-FR 250 V
Standardization
IEC 60092-350/-351/-376
Flame retardant
IEC 60332-1 / IEC 60332-3-22 Cat. A
Conductor category
Class 2 = stranded
Stranding element
Pair
Core insulation
Mica + XLPE
Core identification
Numbers
Construction outer shield
Tinned copper braiding
Screen over stranding element
Alpet tape
Screen over stranding
Foil + braiding
Material outer sheath Flame Retardant Halogen Free Polyolefin Compound
Colour outer sheath
Orange
Maximum conductor temperature
90
Operating temperature, flexible
-20 / 70
Operating temperature, fixed
-40 / 70
Specification
See appendix

Partnumber
26602
26603
26604
26605
26607
26608
26609
26610
26611
26613
26614

Construction
2 x 2 x 0,75 mm
4 x 2 x 0,75 mm
6 x 2 x 0,75 mm
7 x 2 x 0,75 mm
10 x 2 x 0,75 mm
12 x 2 x 0,75 mm
14 x 2 x 0,75 mm
19 x 2 x 0,75 mm
24 x 2 x 0,75 mm
30 x 2 x 0,75 mm
37 x 2 x 0,75 mm

Copyright (c) TKF, 06-03-2012

Conductor
category
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded

Net
weight
(kg/km)
217
314
449
464
695
788
888
1145
1394
1653
2023

Bending
radius
after
installation
(mm)
56
64
78
78
94
99
106
122
136
150
167

Subject to technical alterations

Unit

C
C
C

Outer
diameter
approx.
(mm)
13,9
16
19,4
19,4
23,5
24,8
26,5
30,5
34,1
37,5
41,7

Tensile
load
(N)
45
90
135
158
225
270
315
428
540
675
833

Page 83

Marine & Offshore


Marine2Com YOZ2c X-FR 250 V

Partnumber Construction

Conductor
category

Net
weight
(kg/km)

Bending
radius
after
installation
(mm)

Outer
diameter
approx.
(mm)

Tensile
load
(N)

26647
26721
26648
26722
26649
26650
26723
26651
26652
26724
26653
26654
26725
26655
26726
26656
26727
26657
26658
26659

Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded
Class 2 = stranded

393
478
601
775
857
923
1107
1024
1261
1770
1443
1642
2307
2234
3026
2769
3768
3062
3384
4067

146
155
170
186
204
204
234
219
252
290
263
282
322
326
370
366
414
385
405
445

18,2
19,4
21,3
23,3
25,5
25,5
29,2
27,4
31,5
36,3
32,9
35,3
40,2
40,8
46,2
45,7
51,7
48,1
50,6
55,6

150
225
300
450
450
525
788
600
750
1125
900
1050
1575
1425
2138
1800
2700
2025
2250
2775

2 x 2 x 2,5 mm
2 x 3 x 2,5 mm
4 x 2 x 2,5 mm
4 x 3 x 2,5 mm
6 x 2 x 2,5 mm
7 x 2 x 2,5 mm
7 x 3 x 2,5 mm
8 x 2 x 2,5 mm
10 x 2 x 2,5 mm
10 x 3 x 2,5 mm
12 x 2 x 2,5 mm
14 x 2 x 2,5 mm
14 x 3 x 2,5 mm
19 x 2 x 2,5 mm
19 x 3 x 2,5 mm
24 x 2 x 2,5 mm
24 x 3 x 2,5 mm
27 x 2 x 2,5 mm
30 x 2 x 2,5 mm
37 x 2 x 2,5 mm

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

Page 84

Marine & Offshore


MarineSignal YZs 250 V

Cables designed for signal, control & alarm purposes, with reduced weight & diameter.
The special ripcord provides easy stripping of the outer sheath.
Halogen-free and low-smoke, flame-retardant in fire conditions.
Characteristics

Properties Unit
Signal marine cables
Shipboard cable
MarineSignal YZs 250 V
IEC 60092-350/-351/-376

Product group
Series
Type
Standardization

Flame retardant
IEC 60332-1 / IEC 60332-3-22 Cat. A
Halogen free
IEC 60754-1
Conductor material
Cu
Conductor category
Class 2 = stranded
Shape of conductor
Round
Core insulation
XLPE
Core identification
Numbers
Material outer sheath Flame Retardant Halogen Free Polyolefin Compound
Colour outer sheath
Grey
Nominal voltage U
0.25
Maximum conductor temperature
90
Operating temperature, flexible
-20 / 70
Operating temperature, fixed
-40 / 70
Specification
See appendix

Partnumber
16210
16211
16212
16213
16214
16215
16216
16217
16218

Construction
2 x 0,75 mm
3 x 0,75 mm
4 x 0,75 mm
5 x 0,75 mm
7 x 0,75 mm
12 x 0,75 mm
19 x 0,75 mm
27 x 0,75 mm
37 x 0,75 mm

Shape
of
conductor
Round
Round
Round
Round
Round
Round
Round
Round
Round

16220
16221
17181
16222
16223
16224

2 x 1 mm
3 x 1 mm
3 x 1 mm
4 x 1 mm
5 x 1 mm
7 x 1 mm

Round
Round
Round
Round
Round
Round

Copyright (c) TKF, 06-03-2012

Net
weight
(kg/km)
44
54
66
79
102
160
240
331
443

Bending
radius
after
installation
(mm)
25
26
28
31
34
45
54
63
73

50
62
83
77
93
120

27
28
28
31
34
37

Subject to technical alterations

kV
C
C
C

Outer
diameter
approx.
(mm)
6,3
6,6
7,1
7,7
8,6
11,2
13,5
15,8
18,2

Tensile
load
(N)
23
34
45
56
79
135
214
304
416

6,7
7
7
7,7
8,5
9,2

30
45
45
60
75
105

Page 85

Marine & Offshore


MarineSignal YZs 250 V

Partnumber Construction

Shape
of
conductor

Net
weight
(kg/km)

Bending
radius
after
installation
(mm)

Outer
diameter
approx.
(mm)

Tensile
load
(N)

16225
16226
16227
16228

Round
Round
Round
Round

195
293
403
539

48
59
69
80

12,1
14,8
17,3
20

180
285
405
555

12 x 1 mm
19 x 1 mm
27 x 1 mm
37 x 1 mm

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

Page 86

Marine & Offshore


MarineSignal YOZs 250 V

Armoured cables for signal, control & alarm purposes with reduced weight & diameter.
The tinned copper braid is highly corrosion resistant and provides optimal screening.
The special ripcord provides easy stripping of the outer sheath.
Halogen-free and low-smoke, flame-retardant in fire conditions.
Characteristics

Properties Unit
Signal marine cables
Shipboard cable
MarineSignal YOZs 250 V

Product group
Series
Type

Standardization
IEC 60092-350/-351/-376
Flame retardant
IEC 60332-1 / IEC 60332-3-22 Cat. A
Halogen free
IEC 60754-1
Conductor material
Cu
Conductor category
Class 2 = stranded
Shape of conductor
Round
Core insulation
XLPE
Core identification
Numbers
Construction outer shield
Tinned copper braiding
Material outer sheath Flame Retardant Halogen Free Polyolefin Compound
Colour outer sheath
Grey
Nominal voltage U
0.25
Maximum conductor temperature
90
Operating temperature, flexible
-20 / 70
Operating temperature, fixed
-40 / 70
Specification
See appendix

Partnumber
16241
17185
17187
16242
16243
16244
16245
16246
16247
16248
16249

Construction
2 x 0,75 mm
2 x 0,75 mm
2 x 0,75 mm
3 x 0,75 mm
4 x 0,75 mm
5 x 0,75 mm
7 x 0,75 mm
12 x 0,75 mm
19 x 0,75 mm
27 x 0,75 mm
37 x 0,75 mm

Shape
of
conductor
Round
Round
Round
Round
Round
Round
Round
Round
Round
Round
Round

16250
16251

2 x 1 mm
3 x 1 mm

Round
Round

Copyright (c) TKF, 06-03-2012

Net
weight
(kg/km)
75
100
122
85
103
120
141
218
352
463
599

Bending
radius
after
installation
(mm)
29
32
32
30
32
35
38
48
59
68
78

81
99

30
32

Subject to technical alterations

kV
C
C
C

Outer
diameter
approx.
(mm)
7,2
8
8
7,5
8
8,8
9,5
12,1
14,8
17,1
19,5

Tensile
load
(N)
23
23
23
34
45
56
79
135
214
304
416

7,6
7,9

30
45

Page 87

Marine & Offshore


MarineSignal YOZs 250 V

Partnumber Construction

Shape
of
conductor

Net
weight
(kg/km)

Bending
radius
after
installation
(mm)

Outer
diameter
approx.
(mm)

Tensile
load
(N)

16252
16253
16254
16255
16256
16257
16258
17186

Round
Round
Round
Round
Round
Round
Round
Round

118
135
165
254
494
524
701
125

35
38
40
52
64
74
84
84

8,7
9,4
10,1
13
15,9
18,4
21,1
21,1

60
75
105
180
285
405
555
555

4 x 1 mm
5 x 1 mm
7 x 1 mm
12 x 1 mm
19 x 1 mm
27 x 1 mm
37 x 1 mm
37 x 1 mm

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

Page 88

Marine & Offshore


MarineSignal+ YZs 250 V

Heavy duty cables for signal, control & alarm purposes.


The special ripcord provides easy stripping of the outer sheath.
Halogen-free and low-smoke, flame-retardant in fire conditions.
Characteristics

Properties Unit
Signal marine cables
Shipboard cable
MarineSignal+ YZs 250 V
IEC 60092-350/-351/-376

Product group
Series
Type
Standardization

Flame retardant
IEC 60332-1 / IEC 60332-3-22 Cat. A
Halogen free
IEC 60754-1
Conductor material
Cu
Conductor category
Class 2 = stranded
Shape of conductor
Round
Core insulation
XLPE
Core identification
Numbers
Material outer sheath Flame Retardant Halogen Free Polyolefin Compound
Colour outer sheath
Grey
Nominal voltage U
0.25
Maximum conductor temperature
90
Operating temperature, flexible
-20 / 70
Operating temperature, fixed
-40 / 70
Specification
See appendix

Partnumber
16231
16232
16233
16234

Construction
2 x 0,75 mm
3 x 0,75 mm
4 x 0,75 mm
5 x 0,75 mm

Shape
of
conductor
Round
Round
Round
Round

16235
16236
16237
16238

2 x 1 mm
3 x 1 mm
4 x 1 mm
5 x 1 mm

Round
Round
Round
Round

Copyright (c) TKF, 06-03-2012

Net
weight
(kg/km)
65
72
85
99

Bending
radius
after
installation
(mm)
27
28
30
33

77
84
99
120

29
30
33
36

Subject to technical alterations

kV
C
C
C

Outer
diameter
approx.
(mm)
6,7
7
7,5
8,2

Tensile
load
(N)
23
34
45
56

7,3
7,5
8,2
8,9

30
45
60
75

Page 89

Marine & Offshore


MarineSignal+ YOZs 250 V

Armoured heavy duty signal, control & alarm cables.


The tinned copper braid is highly corrosion resistant and provides optimal screening.
The special ripcord provides easy stripping of the outer sheath.
Halogen-free and low-smoke, flame-retardant in fire conditions.
Characteristics

Properties Unit
Signal marine cables
Shipboard cable
MarineSignal+ YOZs 250 V

Product group
Series
Type

Standardization
IEC 60092-350/-351/-376
Flame retardant
IEC 60332-1 / IEC 60332-3-22 Cat. A
Halogen free
IEC 60754-1
Conductor material
Cu
Conductor category
Class 2 = stranded
Shape of conductor
Round
Core insulation
XLPE
Core identification
Numbers
Construction outer shield
Tinned copper braiding
Material outer sheath Flame Retardant Halogen Free Polyolefin Compound
Colour outer sheath
Grey
Nominal voltage U
0.25
Maximum conductor temperature
90
Operating temperature, flexible
-20 / 70
Operating temperature, fixed
-40 / 70
Specification
See appendix

Partnumber
16261
16262
16263
16264

Construction
2 x 0,75 mm
3 x 0,75 mm
4 x 0,75 mm
5 x 0,75 mm

Shape
of
conductor
Round
Round
Round
Round

16265
16266
16267
16268

2 x 1 mm
3 x 1 mm
4 x 1 mm
5 x 1 mm

Round
Round
Round
Round

Copyright (c) TKF, 06-03-2012

Net
weight
(kg/km)
112
122
139
158

Bending
radius
after
installation
(mm)
32
34
36
39

123
133
155
176

34
36
38
41

Subject to technical alterations

kV
C
C
C

Outer
diameter
approx.
(mm)
8
8,5
9,1
9,7

Tensile
load
(N)
23
34
45
56

8,6
9
9,6
10,2

30
45
60
75

Page 90

Marine & Offshore


Break-Out

Break-out Multimode Fibre Optic cable for use in ships.


Halogen free, flame retardant.
The cable consist of multiple simplex elements suitable for direct connector assembly.
Available in single- and multi-mode fibre types.
Special types available on request.
Characteristics

Properties Unit
Fibre Optic cables
Fibre optic cable Single mode

Product group
Series
Type
Standardization
Test procedures
Application
Cable metal free
Strain relief
Halogen free (acc. EN 50267-2-2)
Low smoke (acc. EN50268-2)
Longitudinal water blocking
Radial water blocking
Type of duct
Fibre type
Optical fibre standard
Strip method
Material outer sheath
Colour outer sheath
Halogen free
Low smoke
Flame retardant
Installation temperature
Operation temperature range
Transportation and storage temperature
Attenuation @ 1310 nm
Attenuation @ 1550 nm

Partnumber
77001
77064
77068
77004
77006
77065
77069
77070
77066

Construction
4 x Single mode (4 x 1)
4 x Single mode (4 x 1)
4 x Single mode (4 x 1)
6 x Single mode (6 x 1)
8 x Single mode (8 x 1)
8 x Single mode (8 x 1)
8 x Single mode (8 x 1)
12 x Single mode (12 x 1)
12 x Single mode (12 x 1)

Copyright (c) TKF, 06-03-2012

Break-Out
Article dependant, see detail sheet
IEC 60794-1-2
Inside
Yes
Yes
Yes
Yes
No
No
Article dependant, see detail sheet
Single mode
ITU-T G.657.A1
1 Rip cord
LSZH
Yellow
Acc. IEC 60754-1
Acc. IEC 61034
Acc. IEC 60332-1-2
Article dependant, see detail sheet
-20 / 60
-30 / 60
0.5
0.5

Bending
radius
during
installation
(mm)
180
150
180
210
240
180
180
250
220

Bending
radius
after
installation
(mm)
130
110
130
155
180
130
135
190
170

Net
weight
(Kg/km)
75
70
70
102
132
83
95
174
126

Subject to technical alterations

C
C
C
dB/km
dB/km

Outer
diameter
approx.
(mm)
9,0
7,4
8,7
10,4
12
8,9
10,1
13
11

Tensile
load
short
term
(Tm)
700
400
900
1000
1000
800
900
1500
1000
Page 91

Marine & Offshore


Break-Out

Partnumber Construction

Bending
radius
during
installation
(mm)

Bending
radius
after
installation
(mm)

Net
weight
(Kg/km)

Outer
diameter
approx.
(mm)

Tensile
load
short
term
(Tm)
(N)

77009
77012
77067
77071
77072

270
350
250
380
350

200
265
190
230
250

217
265
133
192
368

13,5
17,6
12,4
14,8
16,3

1500
2500
1200
1800
1500

12 x Single mode (12 x 1)


24 x Single mode (24 x 1)
24 x Single mode (24 x 1)
24 x Single mode (24 x 1)
48 x Single mode (48 x 1)

Copyright (c) TKF, 06-03-2012

Subject to technical alterations

Page 92

Marine & Offshore


Break-Out LSZH CWB

Break-out Multimode Fibre Optic cable for use in ships.


Armoured, Halogen free, flame retardant.
The armouring gives extra protection in heavy-duty areas.
With SHF-1 sheathing material according to IEC 60092-359.
The cable consists of multiple simplex cables suitable for direct connector assembly around
a central support member. Special types available on request.
Characteristics

Properties Unit
Fibre Optic cables

Product group
Series
Type
Test procedures
Blow in
Strain relief
Type of duct
Fibre type
Optical fibre standard
Material outer sheath
Colour outer sheath
Flame retardant
Installation temperature
Operation temperature range
Transportation and storage temperature
Attenuation @ 850 nm
Attenuation @ 1300 nm

Partnumber Construction
69189
6x MM 62,5/125 (2,4 oranje)

Copyright (c) TKF, 06-03-2012

Fibre optic cable Multi mode


Break-Out LSZH CWB
IEC 60794-1-2
Yes
Yes
Simplex 2.4
Multi mode 62.5/125
ISO/IEC 11801- OM1/ IEC 60793-2-10 A1b
LSZH
Black
Acc. IEC 60332-1-2
-5 / 50
-20 / 60
-30 / 60
3.4
1.3

Bending
radius
during
installation
(mm)
280

Bending
radius
after
installation
(mm)
210

Net
weight
(Kg/km)
274

Subject to technical alterations

C
C
C
dB/km
dB/km

Outer
diameter
approx.
(mm)
14,1

Tensile
load
short
term
(Tm)
-

Page 93

Marine & Offshore


Break-Out LSZH CWB

Hybrid Power + Singlemode armoured Halogen free flame retardant Break-out Fibre Optic cable
for use in ships. The armouring gives extra protection in heavy-duty areas. With SHF-1
sheathing material according to IEC 60092-359.
The cable consists of multiple simplex cables suitable for direct connector assembly around
a central support member. Special types available on request.
Characteristics

Properties Unit
Fibre Optic cables
Fibre optic cable Multi mode

Product group
Series
Type
Standardization
Test procedures
Application
Strain relief
UV resistant
Halogen free (acc. EN 50267-2-2)
Low smoke (acc. EN50268-2)
Type of duct
Fibre type
Optical fibre standard
Material outer sheath
Colour outer sheath
Halogen free
UV-protection
Flame retardant
Installation temperature
Operation temperature range
Transportation and storage temperature
Attenuation @ 850 nm
Attenuation @ 1300 nm

Partnumber Construction
69191
8x MM 62,5/125 + 2x 1,5mm2

Copyright (c) TKF, 06-03-2012

Break-Out LSZH CWB


IEC 60794-2
IEC 60794-1-2
Inside
Yes
Yes
Yes
Yes
Simplex 2.4
Multi mode 62.5/125
ISO/IEC 11801- OM1/ IEC 60793-2-10 A1b
LSZH
Black
Acc. IEC 60754-1
ISO 4892/2
Acc. IEC 60332-1-2
-5 / 50
-20 / 60
-30 / 60
3.0
1.0

Bending
radius
during
installation
(mm)
350

Bending
radius
after
installation
(mm)
260

Subject to technical alterations

Net
weight
(Kg/km)
415

C
C
C
dB/km
dB/km

Outer
diameter
approx.
(mm)
17,5

Tensile
load
short
term
(Tm)
1000

Page 94

Technical Product information

Marine Cables
Materials

International Standards

Insulation
All marine cables are insulated with Cross-Linked
Polyethylene (XLPE) according to IEC 60092-351,
type HF-XLPE. This material allows a continuous
conductor temperature of 90 C and withstands a
temporary overload temperature of 130 C and a
short-circuit temperature of 250 C. This material
offers good low temperature properties with a
brittleness temperature of approximately -50 C.
TKFs XLPE material shows very low dielectric
losses when used in power cables and excellent
transmission properties for the instrumentation
and communication cables. It also has extremely
low moisture absorption, and a high resistance to
most chemicals. The Fire-Resistant cables have
conductors fully wrapped in mica-glass tape
before being insulated with XLPE
insulation.

The Marine cables in this catalogue are designed


and tested in accordance with the following
standards, where applicable.

Sheathing
Standard TKF marine cables have a SHF1 type,
halogen-free, flame retardant, low-smoke sheath.
This sheath has very good abrasion resistance,
good mechanical properties, low moisture
absorption and high resistance to most chemicals.
The material meets the requirements as specified
in IEC 6092-359 under type SHF-1 for mechanical
properties, as well as the IEC 60811-2-1 for oilresistance (ASTM oil 2, 4 hours, 70 C)
The selected sheath material makes TKF marine
cables are very suitable for installation and usage
in areas with low temperatures. If the cables are
exposed to direct sunlight protective covering or
black outer sheath is recommended
On request special sheath materials can be
applied (e.g. TPU or SHF2) for more extreme
conditions.

IEC 60092-354

Armouring and Screening


All TKFs braided cables (designated with the O
in the type designation) have tinned-copper wire
braiding with a coverage of at least 90%. The
tinned wires give a high corrosion resistance of
the braid and offer both mechanical and EMI
protection. Screened cables (af type
designation) offer only EMI protection with aluPET tapes in combination with a tinned copper
drain wire.

Version: PN-M01J11

Standard
IEC 60092-350

IEC 60092-351

IEC 60092-352

IEC 60092-353

IEC 60092-359
IEC 60092-376
IEC 60228
IEC 60331-11

IEC 60331-21

IEC 60332-1
IEC 60332-322 - A
IEC 60754-1
IEC 60811
IEC 61034
series

Subject to technical alterations

Description
General construction and test methods
of power, control and instrumentation
cables for shipboard and offshore
applications
Insulating materials for shipboard
offshore
units, power, control, instrumentation,
telecommunication and data cables
Electrical installations in ships Choice
and installation of cables for lowvoltage power systems
Single and multicore non-radial field
power cables with extruded solid
insulation for rated voltages 1 kV and 3
kV
Single- and three-core power cables
with extruded solid insulation for rated
voltages
6 kV (Um = 7.2 kV) up to 30 kV (Um = 36
kV)
Sheathing materials for shipboard power
and telecommunication cables
Cables for control and instrumentation
circuits 150/250 V (300 V)
Conductors of insulated cables
Tests for electric cables under fire
conditions - circuit integrity - apparatus
- fire alone at a flame temperature of at
least 750 C
Tests for electric cables under fire
conditions - circuit integrity procedures and requirements - cables of
rated voltage up to and including
0.6/1.0 kV
Tests on electric cables under fire
conditions - part 1: test on a single
vertical insulated wire or cable
Tests on electric cables under fire
conditions - part 3-22: test for vertical
flame spread of vertically mounted
bunched wires or cables - category A
Test on gases evolved during combustion
of electric cables - determination of the
amount of halogen acid gas
Common test methods for insulating and
sheathing materials of electric cables
Measurement of smoke density of
electric cables burning under defined
conditions

This datasheet is put together with great care. Nevertheless we cannot give any guarantees regarding the completeness, correctness or actualization of the
information. No rights can be derived from the information as shown. TKF is entitled to modify this datasheet at all times with immediate effect due to
(for example) changes in legislation. TKF cannot be held responsible for the content of this datasheet or the consequences of using the information including
incorrect translation of the information by third parties.

Page 1 / 4

Technical Product information

Marine Cables
Bending Radius
Bending Radii according to IEC 60092-352
Voltage Rating

Up to 1.8/ 3 kV

3.6/6 kV

Cable Construction

Outer Diameter

Bending Radius

Cable Types

Unarmoured
Unarmoured
Armoured/Screened
Foil screened
Single Core
Triple Core

<25 mm
>25 mm
any
any
any
any

R=4xD
R=6xD
R=6xD
R=8xD
R = 12 x D
R=9xD

YZp, YZs
YZp, YZs
YOZp, YOZs, YOZc
YOZ2c, YZafp, YZafc
YOZmv
YZOZmv

Current Rating for General Installations


The current ratings are applicable for d.c. and
a.c. with a nominal frequency of 50 Hz or 60 Hz
and an ambient air temperature of 45 C. For
higher frequencies, the current rating shall be
calculated with an appropriate method (e.g. IEC
60287). For other ambient air temperatures the
correction factors have to be applied. These
ratings are applicable, without correction factors,
for cables bunched together on cable trays, in
cable conduits, pipes or trunking, unless more
than six cables operating simultaneously at their
full rated capacity are laid close together without
free air circulating around them. In this case a
correction factor of 0.85 should be applied. The
tables are for general reference purposes only,
and do not describe all installation methods
existing in practice. For more detailed
information see IEC 60092-352(2005) Annex A & B.
For specific situations not covered by these
standards exact current calculations can be made
by our engineering office.

Current carrying capacities in continuous service


at maximum rated conductor temperature of 90 C in A,
at 45 C ambient air temperature

Correction Factors for ambient air temperatures


for maximum conductor temperature of 90 C

400
500
630

Air
Temperature
Correction
Factor

Current Rating (A)


Cross
Section
(mm2)

Number of cores loaded

1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
d.c.
690
780
890

1
23
40
51
52
72
96
127
157
196
242
293
339
389
444
522
601
a.c.
670
720
780

2
20
26
34
44
61
82
108
133
167
206
249
288
331
377
444
511
d.c.
a.c.
587
570
663
612
757
663

d.c.
483
546
623

3&4
16
21
28
36
50
67
89
110
137
169
205
237
272
311
365
421
a.c.
469
504
548

35 C 40 C 45 C 50 C 55 C 60 C
1.10

1.05

1.00

0.94

0.88

0.82

Air
Temperature

65 C 70 C

75 C 80 C 85 C 90 C

Correction
Factor

0.74

0.58

Version: PN-M01J11

0.67

0.47

Subject to technical alterations

This datasheet is put together with great care. Nevertheless we cannot give any guarantees regarding the completeness, correctness or actualization of the
information. No rights can be derived from the information as shown. TKF is entitled to modify this datasheet at all times with immediate effect due to
(for example) changes in legislation. TKF cannot be held responsible for the content of this datasheet or the consequences of using the information including
incorrect translation of the information by third parties.

Page 2 / 4

Technical Product information

Marine Cables
Short Circuit Current
The maximum
permissible short circuit
current for different
cables is based on the
formula

The formula is
acceptable for an
increase in temperature
from 90C at the start
to 250C at the end
(according to IEC 600933). In the figure the
permissible short-circuit
current is given in kA as
a function of time (from
0.1 to 5 seconds) and as
a function of the cross
sectional area of the
conductor.
Reactance Calculations
The reactance of cables
can be calculated with
the following formula:

2 f L

100

500
400
300
240
185
150
120
95

10

70
50

Cross-sectional are of conductor in mm 2

Ik=the maximum
permissible short-circuit
current in Ampere
S = the cross section
area of the conductor in
mm
t = the duration of the
short-circuit in seconds

Short-circuit current in kA

Ik 146

1000

25

16
10
6

4
2,5

1,5

0,1
0,1

10

Duration of short-circuit in sec.

f = frequency in Hz
L = inductance in H

Version: PN-M01J11

Subject to technical alterations

This datasheet is put together with great care. Nevertheless we cannot give any guarantees regarding the completeness, correctness or actualization of the
information. No rights can be derived from the information as shown. TKF is entitled to modify this datasheet at all times with immediate effect due to
(for example) changes in legislation. TKF cannot be held responsible for the content of this datasheet or the consequences of using the information including
incorrect translation of the information by third parties.

Page 3 / 4

Technical Product information

Marine Cables
Sheath Colours & Core Identification
Overview types, standards, core identification and sheath colour
Application

Type

Standard

Core Identification

Sheath Colour

Low voltage

Marineline (+) Y(O)Z(af)p 0,6/1 kV

IEC 60092-350/-351/-353

HD308 S2-2001

black

MarineFlex Y(O)Zp & YOQp 0,6/1 kV

IEC 60092-350/-351/-353

HD308 S2-2001

black

MarineFlex YOZp 1,8/3 kV

IEC 60092-350/-351/-353

HD308 S2-2001

black

Marineline (+) Y(O)Zp FR 0,6/1 kV

IEC 60331-11/21

HD308 S2-2001

orange

MarinePower Y(Z)OZmv 3,6-30 kV

IEC 60092-350/-351/-354

Coloured tape + numbers

red

MarinePower Multiflex YQOQmv 6/10kV IEC 60092-350/-351/-354

Coloured tape + numbers

red

Marine(2)Com Y(O)Z(af)(2)c 250V

IEC 60092-350/-351/-376

Blue/White cores + numbers

grey

Marine(2)Com Y(O)Z(af)(2)c FR 250V

IEC 60331-11/21

Blue/White cores + numbers

orange

MarineSignal (+) Y(O)Zs 250V

IEC 60092-350/-351/-376

Black cores + numbers


black numbered

grey

Medium voltage
Communication
Signal

Different sheath colours on request

Core Identification
Low voltage power cables 0,6/1 kV -1,8/3kV According to HD308 S2-2001
Without Yellow/Green Conductor
Cond .

L1/L2

L/L2

1
2
3
4
5
>5

L3

With Yellow/Green Conductor (G)


L3

PE

L1/L2

L/L2

Nr.

Notes:

L3

Nr.

1) PE = protective conductor - beschermingsleiding - Schutzleiter - conducteur de protection


N = neutral conductor - nulleiding - Neutralleiter - conducteur neutre
L, L1, L2, L3 = phase conductors - faseleidingen - Phasenleiter - conducteurs de phase
2) NNr.
= black numbered - zwart genummerd - schwarz nummeriert - noir numrot

Communication Cables 250 V

Medium Voltage cables 3,6-30kV

Pairs (n x 2 x y mm2)

1
3..etc

Triple Cores (YZOZmv, YQOQmv)

2
4..etc

Triples (n x 3 x y mm2)

1
4..etc

2
5..etc

Spiral wound
red tape
with number

Spiral wound
white tape
with number

Spiral wound
blue tape
with number

3
6..etc

Signal Cables 250 V


Multicores

1
2..etc

Version: PN-M01J11

Subject to technical alterations

This datasheet is put together with great care. Nevertheless we cannot give any guarantees regarding the completeness, correctness or actualization of the
information. No rights can be derived from the information as shown. TKF is entitled to modify this datasheet at all times with immediate effect due to
(for example) changes in legislation. TKF cannot be held responsible for the content of this datasheet or the consequences of using the information including
incorrect translation of the information by third parties.

Page 4 / 4

Product Characteristics - Optical fibres

Fibre:
type of fibre hydrogen passivated, dispersion unshifted, matched cladding
bending loss insensitive singlemode fibre 9/125m
standard
IEC-60793-2-50, B6-a1
standard
ITU-T G.657.A1

Characteristics:

Properties Unit

Mode field diameter; 1310nm


Mode field diameter; 1550nm
Core non-circularity
Core/Cladding concentricity error
Cladding diameter
Cladding non-circularity
Coating diameter, uncoloured
Coating diameter, coloured
Coating/Cladding concentricity error
Temperature sensitivity; -60C to +85C
Bending sensitivity - 10 turns around 30mm - 1550nm
Bending sensitivity - 10 turns around 30mm - 1625nm
Bending sensitivity - 1 turn around 20mm - 1550nm
Bending sensitivity - 1 turn around 20mm - 1625nm
Proof test level
Fibre curl
Cable cut-off wavelength
Zero-dispersion wavelength
Zero-dispersion slope
Chromatic dispersion; 1285nm - 1330 nm
Chromatic dispersion; 1550nm
Chromatic dispersion; 1625nm
Polarisation mode dispersion; PMDQ
Max. attenuation at 1383nm (1383)
Effective Group Core Refractive Index;
Effective Group Core Refractive Index;
Effective Group Core Refractive Index;

[note a]
1310 nm
1550 nm
1625 nm

9.0 0.3
10.2 0.4
max. 6
max. 0.4
125.0 0.5
max. 0.6
242 5
254 7
max. 8
max. 0.05
max. 0.1
max. 0.3
max. 0.75
max. 1.5
min. 0.69
min. 4
max. 1260
1300 - 1322
max. 0.090
max. 3.0
max. 17.0
max. 21.0
max. 0.20

m
m
%
m
m
%
m
m
m
dB/km
dB
dB
dB
dB
GPa
m
nm
nm
ps/nm.km
ps/nm.km
ps/nm.km
ps/nm.km

ps/km
< max. 1310
1.465 1.465 1.465 -

note a: after hydrogen ageing

Version: 31-08-2010

Subject to technical alterations

BV Twentsche Kabelfabriek
Spinnerstraat 15 - P.O. Box 6 - 7480 AA Haaksbergen The Netherlands
Tel: +31 53 - 573 22 55 - Fax: +31 53 - 573 21 85 - E-mail: info@TKF.nl - www.tkf.nl

Page 1 / 1

Product Characteristics Optical Fibres

Fibre:
type of fibre
standard
standard

graded index multimode fibre 62.5/125m


ISO/IEC-11801, OM1
IEC-60793, A1b

Characteristics:

Properties Unit

Core diameter
Core non-circularity
Core/Cladding concentricity error
Cladding diameter
Cladding non-circularity
Coating diameter, uncoloured
Coating diameter, coloured
Coating non-circularity
Coating/Cladding concentricity error
Temperature sensitivity; -60C to +80C
Bending sensitivity; 100 turns around 75mm
Proof test level
Numerical aperture
Effective Group Core Refractive Index; 850 nm
Effective Group Core Refractive Index; 1300 nm

Version: 8-11-2005

Subject to technical alterations

BV Twentsche Kabelfabriek
Spinnerstraat 15 - P.O. Box 6 - 7480 AA Haaksbergen The Netherlands
Tel: +31 53 - 573 22 55 - Fax: +31 53 - 573 21 85 - info@TKF.nl - www.tkf.nl

62.5 3
max. 6
max. 1.5
125.0 2.0
max. 1.0
245 5
250 15
max. 6
max. 12
max. 0.20
max. 0.5
min. 0.69
0.275 0.015
1.493
1.488

m
%
m
m
%
m
m
%
m
dB/km
dB
GPa
-

Page 1 / 1

Marine & Offshore


Green Passport
As one of the first cable manufacturers, TKF has registered with Det Norske Veritas (DNV) a declaration of
conformity for a "Green Passport" for ships, in June 2009. A Green Passport is an inventory of materials present
in a ships structure, systems and equipment that may be hazardous to health and / or the environment. The
Green Passport was adopted by the IMO by resolution A.962 Clean Design / Green Passport.
A Green Passport is granted to a ship when build. On completion of the ship,
a class society such as DNV issues a certificate of compliance. This, together
with the inventory of hazardous materials and declarations that the ship is
free of certain materials, form the Green Passport. This passport
accompanies the ship throughout its working life. The final ship owner
delivers the Green Passport together with the vessel to the recycling yard, so
that hazardous materials in the ship can be identified and disposed of in an
environmentally clean and safe way.
Yard owners and sub-suppliers must ensure that certain materials are
excluded for new-build ships. Also, they must declare all materials that have been included according to various
categories required by IMO.
TKF marine cables are completely free of hazardous substances and may therefore be used in a ship with a
Green Passport, and do not have to be listed on the inventory of hazardous materials.

Version: 23-06-2009

Subject to technical alterations

www.tkf.nl

Marine Cables
International standards and approvals
All marine cables are designed and produced
according to international standards. TKF marine
cables fully comply with the requirements specified
in the IEC 60092 series of standards.

More information
This catalogue also contains information about
product families. Information at item level can be
requested via our website and from our sales staff.
This catalogue has been customised. Information
about products that have not been included in this
catalogue is available from our sales departments
and can also be found on our website www.tkf.nl.

TKF cant be held responsible for the content of


this catalogue or the consequences of using the
information including incorrect translation of the
information by third parties.
TKF
All rights reserved. Information in this catalogue
may only be distributed with acknowledgement of the
source.
Terms of delivery
Our general terms of delivery apply to all our
deliveries including the products named in the
catalogue. They are available via our website
www.tkf.nl or from our sales departments.
Prices

Please contact us for additional technical or


commercial information. Contact information for our
sales teams can be found on the next page and on
our website.

Please contact our sales department for price


information. The gross item prices of part of our
portfolio have been included in our TPL price list.
It can be downloaded via our website or requested
from our sales staff.

Subject to changes
TKF reserves the right to make changes to its
product specifications and its range of products
without informing its clients of this in advance.
Disclaimer
This catalogue is put together with great care.
Nevertheless we cant give any guarantees
regarding the completeness, correctness or
actualization of the information in this catalogue.
No rights can be derived from the information as
shown in this catalogue.
TKF is entitled to modify this catalogue at all times
with immediate effect due to (for example)
changes in legislation.

BV Twentsche Kabelfabriek

Subject to technical alterations

www.tkf.nl

Global customer service


Please consult the table below for the contact information for our sales teams. The latest information
about our distributors worldwide is available from our sales staff and on our website (www.tkf.nl).
Broadband
Tel. +31 (0)53 573 23 89

Fax +31 (0)53 573 23 06

broadband@tkf.nl

Fax +31 (0)53 573 21 84

energy@tkf.nl

Fax +31 (0)53 573 21 84

marine@tkf.nl

Fax +31 (0)53 573 21 84

installation@tkf.nl

Fax +31 (0)53 573 21 84

industry@tkf.nl

Energy
Tel. +31 (0)53 573 23 86
Marine & Offshore
Tel. +31 (0)53 573 23 90
Installation
Tel. +31 (0)53 573 23 88
Industry
Tel. +31 (0)53 573 23 90
Infra
Tel.+31(0)5357323187

Fax +31 (0)53 573 21 84 infra@tkf.nl

General & Sales Support


Tel. +31 (0)53 573 22 55

Fax +31 (0)53 573 23 61

info@tkf.nl

Cable drum sizes and weights


A wide range of drums with various sizes and weights is used to store and transport our cables.
The most common types of drum and their sizes and weights are shown in this table.
Flange
diameter (F)
mm

Core
Central hole
diameter (K) diameter (A)
mm
mm

Largest
width (B)
mm

Winding
width (W)
mm

Empty
weight
kg

Volume
m3

*600

250

80

468

400

7,5

0,17

*800

400

100

480

400

14

0,31

800

500

100

500

485

43

0,31

*1000

500

100

605

485

28

0,31

1000

500

100

609

485

74

0,61

1200

600

100

724

600

108

1,04

1500

800

100

946

750

160

2,13

1600

800

100

1030

834

240

2,64

1800

900

100

1030

834

400

3,34

2100

900

100

1148

950

450

5,06

2250

1400

100

1122

830

600

5,68

2500

1450

100

1220

930

700

7,63

2500

1450

100

1458

1150

800

9,11

2650

1450

100

1488

1175

850

10,45

2800

1700

100

1520

1157

1050

11,92

3000

1600

100

1600

1235

1150

14,40

W
B

F = Diameter flange
K = Diameter core
A = Diameter axle-hole
B = Largest width
W = Winding width

* Plastic drum
Empty drum return
To get your empty drums in the Netherlands collected quickly, please send your
request to our shipping department via the website (www.tkf.nl) or by e-mail to
haspels@tkf.nl. If drums have to be collected outside the Netherlands, please
contact our sales staff.
BV Twentsche Kabelfabriek

Subject to technical alterations

www.tkf.nl-

K F

Notes

Notes

Notes

TKF

Catalogue

Marine

Choose TKF - Choose quality!

BV Twentsche Kabelfabriek
Spinnerstraat 15
P.O. Box 6

Marine & Offshore cables 2012

7480 AA Haaksbergen

International standards

The Netherlands
Tel.: +31 (0)53 573 22 55
E-mail: marine@tkf.nl
Website: www.tkf.eu

Complete range
May 2011
March
2012

Fax: +31 (0)53 573 21 85

Highly flexible cables

www.tkf.nl

You might also like