MASTERSPEC
08/03 (R 05/05)
PRODUCT MASTERSPEC LICENSED BY ARCOM TO NUCONSTEEL
This PRODUCT MASTERSPEC section is licensed by ARCOM (February, 2004) for distribution by
NUCONSTEEL Commercial Corporation. Changes made to MASTERSPEC by NUCONSTEEL
Commercial Corporation are indicated using underline/strikeout text. Review and accept changes
according to project requirements and specifier's practice. The underline and strikeout portions of the text
in this Section are the sole responsibility of NUCONSTEEL Commercial Corporation. They are not
provided by, endorsed by, or representative of the opinions of ARCOM or The American Institute of
Architects. For more information contact NUCONSTEEL Commercial Corporation, 525 South Locust,
Denton, TX 76201. Phone (940) 891-3050. Fax (940) 891-3090. Website: www.nuconsteel.com. Email:
info@nuconsteel.com.
Division 05 Section "Metal Fabrications" for masonry shelf angles and connections.
Division 09 Section "Gypsum Board Shaft Wall Assemblies" for interior non-loadbearing, metal-stud-framed, shaft-wall assemblies.
Division 09 Section "Gypsum Board" for interior non-load-bearing, metal-stud framing
and ceiling-suspension assemblies.
054000 - 1
0.2
0.3
0.4
0.5
Design framing systems to provide for movement of framing members without damage
or overstressing, sheathing failure, connection failure, undue strain on fasteners and
anchors, or other detrimental effects when subject to seasonal or cyclical day/night
temperature changesa maximum ambient temperature change of 120 deg F (67 deg C).
Design framing system to maintain clearances at openings, to allow for construction
tolerances, and to accommodate live load deflection of primary building structure as
follows:structure.
A.
Upward and downward movement of [1/2 inch (13 mm)] [3/4 inch (19 mm)] [1
inch (25 mm)] [1-1/2 inches (38 mm)].
054000 - 2
Headers: Design according to AISI's "Standard for Cold-Formed Steel Framing - Header
Design."
Design exterior non-load-bearing wall framing to accommodate horizontal deflection
without regard for contribution of sheathing materials.
Roof Trusses: Design according to AISI's "Standard for Cold-Formed Steel Framing Truss Design."
SCHEDULE 3 - SUBMITTALS
PRODUCT DATA SHEET 0 - Product Data: For each type of cold-formed metal framing product and
accessory indicated.
PRODUCT DATA SHEET 1 - Shop Drawings: Show layout, spacings, sizes, thicknesses, and types of
cold-formed metal framing; fabrication; and fastening and anchorage details, including
mechanical fasteners. Show reinforcing channels, opening framing, supplemental framing,
strapping, bracing, bridging, splices, accessories, connection details, and attachment to
adjoining work.
1.1
For cold-formed metal framing indicated to comply with design loads, include structural
analysis data signed and sealed by the qualified professional engineer responsible for
their preparation.
PRODUCT DATA SHEET 2 - Welding certificates: Copies of certificates for welding procedures and
personnel.
PRODUCT DATA SHEET 3 - Qualification Data: For [professional engineer] [testing agency].
PRODUCT DATA SHEET 4 - Product Test Reports: From a qualified testing agency, unless otherwise
stated, indicating that each of the following complies with requirements, based on evaluation of
comprehensive tests for current products:
4.1
4.2
4.3
4.4
4.5
4.6
4.7
Steel sheet.
Expansion anchors.
Power-actuated anchors.
Mechanical fasteners.
Vertical deflection clips.
Horizontal drift deflection clips
Miscellaneous structural clips and accessories.
054000 - 3
Comply with AISI's "Standard for Cold-Formed Steel Framing - General Provisions."
6.2
6.3
Comply with AISI's "Standard for Cold-Formed Steel Framing - Truss Design."
Comply with AISI's "Standard for Cold-Formed Steel Framing - Header Design."
PRODUCT DATA SHEET 7 - Comply with AISI's "Standard for Cold-Formed Steel Framing Prescriptive Method for One and Two Family Dwellings."
PRODUCT DATA SHEET 8 - Preinstallation Conference: Conduct conference at Project site to
comply with requirements in Division 01 Section "Project Management and Coordination."
SCHEDULE 5 - DELIVERY, STORAGE, AND HANDLING
PRODUCT DATA SHEET 0 - Protect cold-formed metal framing from corrosion, deformation, and
other damage during delivery, storage, and handling.
PRODUCT DATA SHEET 1 - Store cold-formed metal framing, protect with a waterproof covering,
and ventilate to avoid condensation.
054000 - 4
Allied Studco.
AllSteel Products, Inc.
California Expanded Metal Products Company.
Clark Steel Framing.
Consolidated Fabricators Corp.; Building Products Division.
Craco Metals Manufacturing, LLC.
Custom Stud, Inc.
Dale/Incor.
Design Shapes in Steel.
Dietrich Metal Framing; a Worthington Industries Company.
Formetal Co. Inc. (The).
Innovative Steel Systems.
MarinoWare; a division of Ware Industries.
NUCONSTEEL Commercial Corporation.
Quail Run Building Materials, Inc.
SCAFCO Corporation.
Southeastern Stud & Components, Inc.
Steel Construction Systems.
Steeler, Inc.
Super Stud Building Products, Inc.
United Metal Products, Inc.
<Insert manufacturer's name.>
SCHEDULE 1 - MATERIALS
PRODUCT DATA SHEET 0 - Steel Sheet: ASTM A 1003/A 1003M, Structural Grade, Type H,
metallic coated, of grade and coating weight as follows:
0.1
0.2
Grade:
[ST33H (ST230H)] [ST50H (ST340H)] [As required by structural
performance] <Insert grade>.
Coating: [G60 (Z180), A60 (ZF180), AZ50 (AZ150), or GF30 (ZGF90)] [G90 (Z275)
or equivalent] <Insert coating weight>.
Clips:
054000 - 5
Minimum Base-Metal Thickness: [0.0329 inch (0.84 mm)] [0.0428 inch (1.09 mm)]
[0.0538 inch (1.37 mm)] [0.0677 inch (1.72 mm)] [0.0966 inch (2.45 mm)].
Flange Width: [1-3/8 inches (35 mm)] [1-5/8 inches (41 mm)] [2 inches (51 mm)] [21/2 inches (63 mm)].
Section Properties: <Insert minimum allowable calculated section modulus, moment
of inertia, and allowable moment.>
PRODUCT DATA SHEET 1 - Steel Track: Manufacturer's standard U-shaped steel track, of web
depths indicated, unpunched, with straight flanges, and as follows:
1.1
1.2
Minimum Base-Metal Thickness: [0.0329 inch (0.84 mm)] [0.0428 inch (1.09 mm)]
[0.0538 inch (1.37 mm)] [0.0677 inch (1.72 mm)] [0.0966 inch (2.45 mm)] [Matching
steel studs].
Flange Width: [1-1/4 inches (32 mm)] <Insert dimension if manufacturer's standard
width is insufficient>.
PRODUCT DATA SHEET 2 - Steel Box or Back-to-Back Headers: Manufacturer's standard C-shapes
used to form header beams, of web depths indicated, punched, with stiffened flanges, and as
follows:
2.1
2.2
2.3
Minimum Base-Metal Thickness: [0.0329 inch (0.84 mm)] [0.0428 inch (1.09 mm)]
[0.0538 inch (1.37 mm)] [0.0677 inch (1.72 mm)] [0.0966 inch (2.45 mm)].
Flange Width: [1-3/8 inches (35 mm)] [1-5/8 inches (41 mm)] [2 inches (51 mm)] [21/2 inches (63 mm)].
Section Properties: <Insert minimum allowable calculated section modulus, moment
of inertia, and allowable moment.>
PRODUCT DATA SHEET 3 - Steel Double-L Headers: Manufacturer's standard L-shapes used to
form header beams, of web depths indicated, and as follows:
3.1
3.2
3.3
Minimum Base-Metal Thickness: [0.0329 inch (0.84 mm)] [0.0428 inch (1.09 mm)]
[0.0538 inch (1.37 mm)] [0.0677 inch (1.72 mm)] [0.0966 inch (2.45 mm)].
Top Flange Width: [1-1/2 inches (38 mm)] [1-5/8 inches (41 mm)] [2 inches (51 mm)]
[2-1/2 inches (63 mm)].
Section Properties: <Insert minimum allowable calculated section modulus, moment
of inertia, and allowable moment.>
Minimum Base-Metal Thickness: [0.0329 inch (0.84 mm)] [0.0428 inch (1.09 mm)]
[0.0538 inch (1.37 mm)] [0.0677 inch (1.72 mm)] [0.0966 inch (2.45 mm)].
054000 - 6
Flange Width: [1-3/8 inches (35 mm)] [1-5/8 inches (41 mm)] [2 inches (51 mm)] [21/2 inches (63 mm)].
Section Properties: <Insert minimum allowable calculated section modulus, moment
of inertia, and allowable moment.>
PRODUCT DATA SHEET 1 - Steel Track: Manufacturer's standard U-shaped steel track, of web
depths indicated, unpunched, with unstiffened flanges, and as follows:
1.1
1.2
Minimum Base-Metal Thickness: [0.0329 inch (0.84 mm)] [0.0428 inch (1.09 mm)]
[0.0538 inch (1.37 mm)] [0.0677 inch (1.72 mm)] [0.0966 inch (2.45 mm)] [Matching
steel studs].
Flange Width: [1-1/4 inches (32 mm)] <Insert dimension if manufacturer's standard
width is insufficient>.
PRODUCT DATA SHEET 2 - Vertical Deflection Clips: Manufacturer's standard [bypass] [head]
clips, capable of accommodating upward and downward vertical displacement of primary
structure through positive mechanical attachment to stud web.
2.1
2.2
PRODUCT DATA SHEET 3 - Single Deflection Track: Manufacturer's single, deep-leg, U-shaped
steel track; unpunched, with unstiffened flanges, of web depth to contain studs while allowing
free vertical movement, with flanges designed to support horizontal and lateral loads and
transfer them to the primary structure, and as follows:
3.1
3.2
3.3
3.4
Minimum Base-Metal Thickness: [0.0428 inch (1.09 mm)] [0.0538 inch (1.37 mm)]
[0.0677 inch (1.72 mm)] [0.0966 inch (2.45 mm)].
Flange Width: [1 inch (25 mm) plus the design gap for 1-story structures] [and] [1
inch (25 mm) plus twice the design gap for other applications] <Insert dimension>.
PRODUCT DATA SHEET 4 - Double Deflection Tracks: Manufacturer's double, deep-leg, U-shaped
steel tracks, consisting of nested inner and outer tracks; unpunched, with unstiffened flanges.
COLD-FORMED METAL FRAMING
054000 - 7
Outer Track: Of web depth to allow free vertical movement of inner track, with flanges
designed to support horizontal and lateral loads and transfer them to the primary
structure, and as follows:
A.
B.
4.2
Minimum Base-Metal Thickness: [0.0428 inch (1.09 mm)] [0.0538 inch (1.37
mm)] [0.0677 inch (1.72 mm)] [0.0966 inch (2.45 mm)].
Flange Width: [1 inch (25 mm) plus the design gap for 1-story structures]
[and] [1 inch (25 mm) plus twice the design gap for other applications] <Insert
dimension>.
Minimum Base-Metal Thickness: [0.0428 inch (1.09 mm)] [0.0538 inch (1.37
mm)] [0.0677 inch (1.72 mm)] [0.0966 inch (2.45 mm)].
Flange Width: <Insert dimension equal to sum of outer deflection track flange
width plus 1 inch (25 mm).>
PRODUCT DATA SHEET 5 - Drift Clips: Manufacturer's standard bypass or head clips, capable of
isolating wall stud from upward and downward vertical displacement and lateral drift of
primary structure.
SCHEDULE 4 - FLOOR JOIST FRAMING
PRODUCT DATA SHEET 0 - Steel Joists: Manufacturer's standard C-shaped steel joists, of web
depths indicated, [unpunched,] [punched,] [punched, with enlarged service holes,] with
stiffened flanges, and as follows:
0.1
0.2
0.3
Minimum Base-Metal Thickness: [0.0329 inch (0.84 mm)] [0.0428 inch (1.09 mm)]
[0.0538 inch (1.37 mm)] [0.0677 inch (1.72 mm)] [0.0966 inch (2.45 mm)].
Flange Width: [1-5/8 inches (41 mm)] [2 inches (51 mm)] [2-1/2 inches (63 mm)],
minimum.
Section Properties: <Insert minimum allowable calculated section modulus, moment
of inertia, and allowable moment.>
PRODUCT DATA SHEET 1 - Steel Joist Track: Manufacturer's standard U-shaped steel joist track, of
web depths indicated, unpunched, with unstiffened flanges, and as follows:
1.1
1.2
Minimum Base-Metal Thickness: [0.0329 inch (0.84 mm)] [0.0428 inch (1.09 mm)]
[0.0538 inch (1.37 mm)] [0.0677 inch (1.72 mm)] [0.0966 inch (2.45 mm)] [Matching
steel joists].
Flange Width: [1-5/8 inches (41 mm)] [2 inches (51 mm)] [2-1/2 inches (63 mm)],[11/4 inches (32 mm)] <Insert dimension> , minimum.
054000 - 8
Minimum Base-Metal Thickness: [0.0269 inch (0.68 mm)] [0.0329 inch (0.84 mm)]
[0.0428 inch (1.09 mm)] [0.0538 inch (1.37 mm)] [0.0677 inch (1.72 mm)] [0.0966
inch (2.45 mm)].
Flange Width: [1-5/8 inches (41 mm)] [2 inches (51 mm)] [2-1/2 inches (63 mm)],
minimum.
Section Properties: <Insert minimum allowable calculated section modulus, moment
of inertia, and allowable moment.>
Minimum Base-Metal Thickness: [0.0329 inch (0.84 mm)] [0.0428 inch (1.09 mm)]
[0.0538 inch (1.37 mm)] [0.0677 inch (1.72 mm)] [0.0966 inch (2.45 mm)].
Flange Width: [1-5/8 inches (41 mm)] [2 inches (51 mm)] [2-1/2 inches (63 mm)],
minimum.
Section Properties: <Insert minimum allowable calculated section modulus, moment
of inertia, and allowable moment.>
PRODUCT DATA SHEET 1 - Built-up Members: Built-up members of manufacturer's standard Cshaped steel section, with stiffened flanges, nested into a U-shaped steel section joist track, with
unstiffened flanges; unpunched; of web depths indicated; and as follows:
1.1
1.2
Minimum Base-Metal Thickness: [0.0329 inch (0.84 mm)] [0.0428 inch (1.09 mm)]
[0.0538 inch (1.37 mm)] [0.0677 inch (1.72 mm)] [0.0966 inch (2.45 mm)] [Matching
steel rafters].
Flange Width: [1-5/8 inches (41 mm)] [2 inches (51 mm)] [2-1/2 inches (63 mm)],
minimum.
Minimum Base-Metal Thickness: [0.0329 inch (0.84 mm)] [0.0428 inch (1.09 mm)]
[0.0538 inch (1.37 mm)] [0.0677 inch (1.72 mm)] [0.0966 inch (2.45 mm)].
Flange Width: [1-5/8 inches (41 mm)] [2 inches (51 mm)] [2-1/2 inches (63 mm)],
minimum.
Section Properties: <Insert minimum allowable calculated section modulus, moment
of inertia, and allowable moment.>
054000 - 9
and
Supplementary framing.
Bracing, bridging, and solid blocking.
Web stiffeners.
Anchor clips.
End clips.
Foundation clips.
Gusset plates.
Stud kickers, knee braces, and girts.
Joist hangers and end closures.
Hole reinforcing plates.
Backer plates.
[SSPC-Paint 20 or DOD-P-21035]
054000 - 10
0.4
Comply with AWS D1.3 requirements and procedures for welding, appearance and
quality of welds, and methods used in correcting welding work.
Locate mechanical fasteners and install according to Shop Drawings, with screw
penetrating joined members by not less than three exposed screw threads.
PRODUCT DATA SHEET 1 - Reinforce, stiffen, and brace framing assemblies to withstand handling,
delivery, and erection stresses. Lift fabricated assemblies to prevent damage or permanent
distortion.
PRODUCT DATA SHEET 2 - Fabrication Tolerances: Fabricate assemblies level, plumb, and true to
line to a maximum allowable tolerance variation of 1/8 inch in 10 feet (1:960) and as follows:
2.1
2.2
Spacing: Space individual framing members no more than plus or minus 1/8 inch (3 mm)
from plan location. Cumulative error shall not exceed minimum fastening requirements
of sheathing or other finishing materials.
Squareness: Fabricate each cold-formed metal framing assembly to a maximum out-ofsquare tolerance of 1/8 inch (3 mm).
054000 - 11
Proceed with installation only after unsatisfactory conditions have been corrected.
SCHEDULE 1 - PREPARATION
PRODUCT DATA SHEET 0 - Before sprayed fire-resistive materials are applied, attach continuous
angles, supplementary framing, or tracks to structural members indicated to receive sprayed
fire-resistive materials.
PRODUCT DATA SHEET 1 - After applying sprayed fire-resistive materials, remove only as much of
these materials as needed to complete installation of cold-formed framing without reducing
thickness of fire-resistive materials below that are required to obtain fire-resistance rating
indicated. Protect remaining fire-resistive materials from damage.
PRODUCT DATA SHEET 2 - Install load bearing shims or grout between the underside of wall
bottom track or rim track and the top of foundation wall or slab at stud or joist locations to
ensure a uniform bearing surface on supporting concrete or masonry construction.
PRODUCT DATA SHEET 3 - Install sealer gaskets to isolate the underside of wall bottom track or
rim track and the top of foundation wall or slab at stud or joist locations.
SCHEDULE 2 - INSTALLATION, GENERAL
PRODUCT DATA SHEET 0 - Cold-formed metal framing may be shop or field fabricated for
installation, or it may be field assembled.
PRODUCT DATA SHEET 1 - Install cold-formed metal framing according to AISI's "Standard for
Cold-Formed Steel Framing - General Provisions" and to manufacturer's written instructions
unless more stringent requirements are indicated.
PRODUCT DATA SHEET 2 - Install shop- or field-fabricated, cold-formed framing and securely
anchor to supporting structure.
2.1
Screw, bolt, or weld wall panels at horizontal and vertical junctures to produce flush,
even, true-to-line joints with maximum variation in plane and true position between
fabricated panels not exceeding 1/16 inch (1.6 mm).
PRODUCT DATA SHEET 3 - Install cold-formed metal framing and accessories plumb, square, and
true to line, and with connections securely fastened.
3.1
054000 - 12
Comply with AWS D1.3 requirements and procedures for welding, appearance and
quality of welds, and methods used in correcting welding work.
Locate mechanical fasteners and install according to Shop Drawings, and
complying with requirements for spacing, edge distances, and screw penetration.
PRODUCT DATA SHEET 4 - Install framing members in one-piece lengths unless splice connections
are indicated for track or tension members.
PRODUCT DATA SHEET 5 - Install temporary bracing and supports to secure framing and support
loads comparable in intensity to those for which structure was designed. Maintain braces and
supports in place, undisturbed, until entire integrated supporting structure has been completed
and permanent connections to framing are secured.
PRODUCT DATA SHEET 6 - Do not bridge building expansion and control joints with cold-formed
metal framing. Independently frame both sides of joints.
PRODUCT DATA SHEET 7 - Install insulation, specified in Division 07 Section "Thermal
Insulation," in built-up exterior framing members, such as headers, sills, boxed joists, and
multiple studs at openings, that are inaccessible on completion of framing work.
PRODUCT DATA SHEET 8 - Fasten hole reinforcing plate over web penetrations that exceed size of
manufacturer's standard punched openings.
PRODUCT DATA SHEET 9 - Erection Tolerances: Install cold-formed metal framing level, plumb,
and true to line to a maximum allowable tolerance variation of 1/8 inch in 10 feet (1:960) and as
follows:
9.1
Space individual framing members no more than plus or minus 1/8 inch (3 mm) from
plan location. Cumulative error shall not exceed minimum fastening requirements of
sheathing or other finishing materials.
Anchor Spacing: [24 inches (610 mm)] [32 inches (813 mm)] [To match stud spacing]
[As shown on Shop Drawings].
PRODUCT DATA SHEET 1 - Squarely seat studs against top and bottom tracks with gap not
exceeding of 1/8 inch (3 mm) between the end of wall framing member and the web of track.
Fasten both flanges of studs to top and bottom tracks. Space studs as follows:
1.1
1.2
Stud Spacing: [12 inches (305 mm)] [16 inches (406 mm)] [19.2 inches (488 mm)] [24
inches (610 mm)] [As indicated].
Stud Spacing: [300 mm] [400 mm] [600 mm] [As indicated].
054000 - 13
Frame wall openings with not less than a double stud at each jamb of frame as indicated
on Shop Drawings. Fasten jamb members together to uniformly distribute loads.
Install runner tracks and jack studs above and below wall openings. Anchor tracks to
jamb studs with screws, clip angles or by welding, and space jack studs same as fullheight wall studs.
PRODUCT DATA SHEET 7 - Install supplementary framing, blocking, and bracing in stud framing
indicated to support fixtures, equipment, services, casework, heavy trim, furnishings, and
similar work requiring attachment to framing.
7.1
PRODUCT DATA SHEET 8 - Install horizontal bridging in stud system, spaced [48 inches (1220
mm)] [as indicated] [as indicated on Shop Drawings]. Fasten at each stud intersection.
8.1
8.2
8.3
PRODUCT DATA SHEET 9 - Install steel sheet diagonal bracing straps to both stud flanges, terminate
at and fasten to reinforced top and bottom tracks. Fasten clip-angle connectors to multiple studs
at ends of bracing and anchor to structure.
PRODUCT DATA SHEET 10 - Install miscellaneous framing and connections, including
supplementary framing, web stiffeners, clip angles, continuous angles, anchors, and fasteners, to
provide a complete and stable wall-framing system.
054000 - 14
Stud Spacing: [12 inches (305 mm)] [16 inches (406 mm)] [19.2 inches (488 mm)] [24
inches (610 mm)] [As indicated].
Stud Spacing: [300 mm] [400 mm] [480 mm] [600 mm] [As indicated].
PRODUCT DATA SHEET 2 - Set studs plumb, except as needed for diagonal bracing or required for
nonplumb walls or warped surfaces and similar requirements.
PRODUCT DATA SHEET 3 - Isolate non-load-bearing steel framing from building structure to
prevent transfer of vertical loads while providing lateral support.
3.1
3.2
3.3
3.4
PRODUCT DATA SHEET 4 - Install horizontal bridging in wall studs, spaced in rows indicated on
Shop Drawings but not more than 48 inches (1220 mm) apart. Fasten at each stud intersection.
4.1
Top Bridging for Single Deflection Track: Install row of horizontal bridging within [12
inches (305 mm)] [18 inches (450 mm)] of single deflection track. Install a combination
of flat, taut, steel sheet straps of width and thickness indicated and stud or stud-track solid
blocking of width and thickness matching studs. Fasten flat straps to stud flanges and
secure solid blocking to stud webs or flanges.
A.
4.2
4.3
4.4
PRODUCT DATA SHEET 5 - Install miscellaneous framing and connections, including stud kickers,
web stiffeners, clip angles, continuous angles, anchors, fasteners, and stud girts, to provide a
complete and stable wall-framing system.
SCHEDULE 5 - JOIST INSTALLATION
COLD-FORMED METAL FRAMING
054000 - 15
Install joists over supporting frame with a minimum end bearing of 1-1/2 inches (38
mm).
Reinforce ends and bearing points of joists with web stiffeners, end clips, joist hangers,
steel clip angles, or steel-stud sections as indicated on Shop Drawings.
PRODUCT DATA SHEET 2 - Space joists not more than 2 inches (51 mm) from abutting walls, and
as follows:
2.1
2.2
Joist Spacing: [12 inches (305 mm)] [16 inches (406 mm)] [19.2 inches (488 mm)] [24
inches (610 mm)] [As indicated].
Joist Spacing: [300 mm] [400 mm] [480 mm] [600 mm] [As indicated].
PRODUCT DATA SHEET 3 - Frame openings with built-up joist headers consisting of joist and joist
track, nesting joists, or another combination of connected joists if indicated.
PRODUCT DATA SHEET 4 - Install joist reinforcement at interior supports with single, short length
of joist section located directly over interior support, with lapped joists of equal length to joist
reinforcement, or as indicated[ on Shop Drawings].
4.1
Fasten
Bridging: Joist-track solid blocking of width and thickness indicated, secured to joist
webs.
Bridging: Combination of flat, taut, steel sheet straps of width and thickness indicated
and joist-track solid blocking of width and thickness indicated. Fasten flat straps to
bottom flange of joists and secure solid blocking to joist webs.
PRODUCT DATA SHEET 6 - Secure joists to load-bearing interior walls to prevent lateral movement
of bottom flange.
PRODUCT DATA SHEET 7 - Install miscellaneous joist framing and connections, including web
stiffeners, closure pieces, clip angles, continuous angles, hold-down angles, anchors, and
fasteners, to provide a complete and stable joist-framing assembly.
SCHEDULE 6 - TRUSS INSTALLATION
PRODUCT DATA SHEET 0 - Install, bridge, and brace trusses according to Shop Drawings and
requirements in this Section.
054000 - 16
054000 - 17